• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 38
  • Tagged with
  • 38
  • 28
  • 15
  • 13
  • 13
  • 13
  • 13
  • 11
  • 9
  • 7
  • 7
  • 6
  • 6
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Avaliação eletrorretinográfica de ratos wistar jovens submetidos à tireoidectomia bilateral

RODRIGUES, Keuri Eleutério 2012 October 1931 (has links)
Submitted by Edisangela Bastos (edisangela@ufpa.br) on 2013-03-04T21:43:06Z No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Dissertacao_AvaliacaoEletrorretinograficaRatos.pdf: 1553874 bytes, checksum: 9e5c2b5ed2780fd8950f95bee4a7d614 (MD5) / Approved for entry into archive by Ana Rosa Silva(arosa@ufpa.br) on 2013-03-05T17:11:29Z (GMT) No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Dissertacao_AvaliacaoEletrorretinograficaRatos.pdf: 1553874 bytes, checksum: 9e5c2b5ed2780fd8950f95bee4a7d614 (MD5) / Made available in DSpace on 2013-03-05T17:11:29Z (GMT). No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Dissertacao_AvaliacaoEletrorretinograficaRatos.pdf: 1553874 bytes, checksum: 9e5c2b5ed2780fd8950f95bee4a7d614 (MD5) Previous issue date: 2012 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / UFPA - Universidade Federal do Pará / A tireoide sintetiza a tiroxina (T4) e a 3,5,3’-triiodotironina (T3), ambos hormônios apresentam uma função crucial no desenvolvimento do sistema nervoso central, incluindo o sistema visual e a retina. A diminuição dos níveis sanguíneos do T3 e T4 ocasionam uma síndrome denominada de hipotireoidismo, o que pode levar à prejuízos visuais. Os déficits visuais gerados pelo hipotireoidismo estão diretamente relacionados ao período de desenvolvimento do indivíduo. Foi demonstrado em modelos murinos que o hipotireoidismo congênito diminui a espessura da retina, o número de células, e interfere na diferenciação da subpopulação de cones M. Desta forma buscaremos investigar possíveis alterações funcionais na retina de ratos wistar jovens após a tireoidectomia bilateral, utilizando respostas eletrofisiológicas não invasivas. Para tanto, dividimos os ratos em três grupos (controle, sham e tireoidectomizado) cada um contendo ≥ 8 animais. As cirurgias foram realizadas 30 dias pós-natal. Os eletrorretinogramas de campo total foram realizados 10, 15, 20, 25 e 30 dias após a cirurgia, utilizando protocolos para avaliar a resposta escotópica máxima, resposta fotópica (com e sem o uso de filtros de luz) e a resposta ao flicker (12, 15, 18 e 30 Hz). Os parâmetros analisados foram o tempo implícito e a amplitude das ondas a e b. Além disso, realizamos o monitoramento dos parâmetros clínicos dos animais, visando identificar características que indiquem um quadro de hipotireoidismo, bem como a dosagem dos hormônios tireoidianos. Os resultados obtidos demonstraram que em todos dos protocolos de estimulação utilizados no ERG houve diminuição nas amplitudes das ondas a e b nos animais tireoidectomizados em todos os dias avaliados após a cirurgia, quando comparados com animais do grupo controle e sham. Os resultados da avaliação do tempo implícito para ambas as ondas não demonstraram diferença estatística quando comparamos os diversos grupos ao controle. Também podemos constatar uma redução do ganho de peso e tamanho nos animais que sofreram tireoidectomia, associados à redução dos níveis de hormônio tireoidiano (T3). Concluímos dessa forma que os hormônios tireoidianos estão diretamente ligados a alterações funcionais na retina dos animais que sofreram tireoidectomia, bem com, na redução da aquisição de peso e aumento de tamanho. / The thyroid synthesizes thyroxine (T4) and 3,5,3 '-triiodothyronine (T3), both hormones have a crucial role in the development of the central nervous system, including the retina and visual system. The decrease in blood levels of T3 and T4 causes a syndrome called hypothyroidism, which may lead to visual impairment. The visual deficits generated by hypothyroidism are directly related to the development period of the individual. It has been demonstrated in murine models that congenital hypothyroidism decreases the retinal thickness, the number of cells and interferes with the differentiation of M cones. Here, we investigated the possible functional changes in juvenile rat’s retina after bilateral thyroidectomy using noninvasive electrophysiological responses. Therefore, we divided the rats into three groups (control, sham and thyreoidectomized) each containing n≥8 animals. The surgeries were performed 30 days post-natal and the full-field electroretinogram (ERG) were performed 10, 15, 20, 25 and 30 days after surgery, using standard protocols for assessing the scotopic response maximum, photopic response (with and without the use of light filters) and response to flicker (12, 15, 18 and 30 Hz). The parameters analyzed were implicit time and amplitude of a- and b-waves of ERG. We also perform monitoring of clinical parameters of animals in order to identify characteristics that indicate a hypothyroidism, as well as the dosage of thyroid hormones. The results showed that there was a decrease in the a- and b-waves amplitudes in thyroidectomy animals (10, 15, 20, 25 and 30 days after surgery), compared to control and sham animals at all the stimulation protocols used in ERG. The results of the evaluation of the implicit time for both waves showed none statistical difference when comparing to control and sham groups. Also we observed a reduction in size and weight of thyroidectomy animals, associated with reduced levels of thyroid hormone (T3). Thus we concluded that the thyroid hormones are directly related to functional changes in the retina of thyroidectomy animals, together with the reduction of weight and size.
2

Padronização e comparação dos valores ecobiométricos e eletrorretinográficos em cães hígidos das raças Terrier Brasileiro e Beagle /

Guimarães, Patrícia Jordão. January 2011 (has links)
Orientador: José Luiz Laus / Coorientador: Alexandre Pinto Ribeiro / Banca: Alexandre Lima de Andrade / Banca: Cristiane dos Santos Honsho / Resumo: Com a pesquisa, objetivou-se padronizar e comparar valores ecobiométricos e eletrorretinográficos em cães das raças terrier brasileiro e beagle. Utilizaram-se vinte cães, sendo dez da raça terrier brasileiro e dez da beagle, machos e fêmeas hígidos. A ecobiometria foi realizada por ultrassonografia em modos A e B sob contenção física. Avaliaram-se o diâmetro axial do olho, a espessura da lente e os comprimentos das câmaras anterior e vítrea. A eletrorretinografia foi realizada de acordo com o protocolo Dog Diagnostic Protocol sob anestesia com propofol. Os dados foram analizados em software HMsERG, onde mensuraram-se as amplitudes e os seus respectivos tempos implícitos. Em ambas as raças estudadas, não se observaram diferenças significativas entre os olhos direito e esquerdo, quanto aos valores mensurados à ecobiometria ocular (p>0,05). Todavia, os valores relativos ao comprimento axial (p=0,023) e a câmara anterior (p=0,01) de cães da raça beagle foram significativamente maiores que os da raça terrier brasileiro. Nos períodos de resposta de adaptação dos bastonetes, não houve diferença estatística entre as raças (p>0,05). Relativamente à resposta mista, embora sem diferença estatística, observou-se que as amplitudes das ondas A (p=0,24) e B (p=0,23) na raça terrier brasileiro, foram respectivamente, 51,78% e 17,30% maiores que na raça beagle. Não houve significância para valores de onda B nas fases fotópticas, entretanto, o tempo implícito na raça beagle foi significativamente maior (p=0,03) na fase clara com luz estroboscópica. Conclui-se que a câmara anterior e o diâmetro axial do bulbo dos olhos de beagles apresentam comprimentos significativamente maiores que os de terrier braileiros. Embora os parâmetros eletrorretinográficos não tenham diferido significativamente entre as... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of the present study were to standardize and compare echobiometric and eletrorretinographic values in the brazilian terrier and beagle breeds. Twenty healthy dogs, being ten brazilians terrier and ten beagles, of both gender, were employed in this study. The echobiometry was accomplished by means of A and B mode ultrassonography under physical restrain. Axial globe length, lens thickness, anterior and vitreous chamber depth were evaluated. Electroretinography was performed using the Dog Diagnostic Protocol under anesthesia with propofol. Eletroretinographic recordings were evaluated with specific software, where the A and B wave amplitudes and their implicit times were measured. Echobiometric values did not change significantly between right and left eyes in both breeds (P>0.05). During rod response data did not change significantly between breeds (P>0.05). On mixed response, statistical difference was not observed, however, A (P=0.24) and B (P=0.23) wave amplitudes were, respectively, 51.78% and 17.30% higher in brazilian terrier breed. During the photoptic period, B wave amplitudes did not change significantly, however the implicit time seen with stroboscopic light was significantly higher (P=0.03) in beagles. It is concluded that anterior chamber depth and axial globe length were significantly higher in beagles than in brasilian terriers. Though, eletroretinographic values did not change significantly between breeds, higher amplitudes and shorter implicit time were seen in brazilian terriers, suggesting that such findings may be related to its smaller eyes / Mestre
3

Padronização e comparação dos valores ecobiométricos e eletrorretinográficos em cães hígidos das raças Terrier Brasileiro e Beagle

Guimarães, Patrícia Jordão [UNESP] 28 February 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:23:42Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-02-28Bitstream added on 2014-06-13T18:51:08Z : No. of bitstreams: 1 guimaraes_pj_me_jabo.pdf: 341115 bytes, checksum: 109770fb0b798c5964a07df11b13e7d8 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Com a pesquisa, objetivou-se padronizar e comparar valores ecobiométricos e eletrorretinográficos em cães das raças terrier brasileiro e beagle. Utilizaram-se vinte cães, sendo dez da raça terrier brasileiro e dez da beagle, machos e fêmeas hígidos. A ecobiometria foi realizada por ultrassonografia em modos A e B sob contenção física. Avaliaram-se o diâmetro axial do olho, a espessura da lente e os comprimentos das câmaras anterior e vítrea. A eletrorretinografia foi realizada de acordo com o protocolo Dog Diagnostic Protocol sob anestesia com propofol. Os dados foram analizados em software HMsERG, onde mensuraram-se as amplitudes e os seus respectivos tempos implícitos. Em ambas as raças estudadas, não se observaram diferenças significativas entre os olhos direito e esquerdo, quanto aos valores mensurados à ecobiometria ocular (p>0,05). Todavia, os valores relativos ao comprimento axial (p=0,023) e a câmara anterior (p=0,01) de cães da raça beagle foram significativamente maiores que os da raça terrier brasileiro. Nos períodos de resposta de adaptação dos bastonetes, não houve diferença estatística entre as raças (p>0,05). Relativamente à resposta mista, embora sem diferença estatística, observou-se que as amplitudes das ondas A (p=0,24) e B (p=0,23) na raça terrier brasileiro, foram respectivamente, 51,78% e 17,30% maiores que na raça beagle. Não houve significância para valores de onda B nas fases fotópticas, entretanto, o tempo implícito na raça beagle foi significativamente maior (p=0,03) na fase clara com luz estroboscópica. Conclui-se que a câmara anterior e o diâmetro axial do bulbo dos olhos de beagles apresentam comprimentos significativamente maiores que os de terrier braileiros. Embora os parâmetros eletrorretinográficos não tenham diferido significativamente entre as... / The aim of the present study were to standardize and compare echobiometric and eletrorretinographic values in the brazilian terrier and beagle breeds. Twenty healthy dogs, being ten brazilians terrier and ten beagles, of both gender, were employed in this study. The echobiometry was accomplished by means of A and B mode ultrassonography under physical restrain. Axial globe length, lens thickness, anterior and vitreous chamber depth were evaluated. Electroretinography was performed using the Dog Diagnostic Protocol under anesthesia with propofol. Eletroretinographic recordings were evaluated with specific software, where the A and B wave amplitudes and their implicit times were measured. Echobiometric values did not change significantly between right and left eyes in both breeds (P>0.05). During rod response data did not change significantly between breeds (P>0.05). On mixed response, statistical difference was not observed, however, A (P=0.24) and B (P=0.23) wave amplitudes were, respectively, 51.78% and 17.30% higher in brazilian terrier breed. During the photoptic period, B wave amplitudes did not change significantly, however the implicit time seen with stroboscopic light was significantly higher (P=0.03) in beagles. It is concluded that anterior chamber depth and axial globe length were significantly higher in beagles than in brasilian terriers. Though, eletroretinographic values did not change significantly between breeds, higher amplitudes and shorter implicit time were seen in brazilian terriers, suggesting that such findings may be related to its smaller eyes
4

Estudo da eletrorretinografia do camundongo modelo de alzheimer (3xTg-AD) / Study of the electroretinogram of the Alzheimer\'s disease model mouse (3xTg-AD)

Ioshimoto, Gabriela Lourençon 02 March 2011 (has links)
Objetivo: Avaliar eletrofisiologicamente a função da retina do camundongo modelo de Alzheimer (3xTg-AD) comparando com seu controle (b6;129-PS1) em um estudo longitudinal com seis idades (2, 4, 6, 8, 10 e 12 meses). Métodos: Eletrorretinogramas (ERGs) foram registrados em 44 camundongos 3xTg-AD e em 23 controles, após administrada anestesia. Para o registro foi colocado um eletrodo de lente de contato sobre a córnea, um eletrodo de referência na cabeça e um terra na cauda. Em sessão de 30-40min de duração foram expostos ao seguinte protocolo de estimulação: 1) Adaptação ao escuro seguida de flashes nas intensidades: 0,003; 0,03; 0,3; 3 e 30 cd.s/m2; 2) Estimulação periódica (30 cd.s/m2) nas freqüências de 12, 18, e 30 Hz, sob luz de fundo (30 cd/m2). Resultados: Os ERGs mostraram dois tipos de respostas escotópicas tanto no grupo dos camundongos controles (b6;129- PS1) quanto nos modelos de Alzheimer. 13% dos camundongos controles e 72% dos modelos de AD apresentaram ERGs com potenciais oscilatórios presentes e tempo implícito da onda-b dentro da faixa esperada (45,31 ± 6,74 ms), enquanto no restante dos grupos, o ERG apresentou latência da onda-b muito aumentada (111,73 ± 22,56 ms) e potenciais oscilatórios ausentes. Devido a estes resultados, os grupos controle e experimental foram subdivididos em: b6;129 com OP, b6;129 sem OP; 3xTg-AD com OP e 3xTg-AD sem OP. Também foi incluído um grupo controle adicional constituído por 9 camundongos C57/B6. Comparando os cinco grupos, nenhuma diferença foi encontrada em relação à amplitude e à latência da onda-a. A amplitude da onda-b também foi semelhante para todos, ao contrário da latência para atingir o pico da onda-b dos grupos b6;129 sem OP e 3xTg-AD sem OP, que se apresentou duas vezes maior do que nos grupos com OP. As amplitudes dos cinco potenciais oscilatórios foram medidas individualmente e não mostraram diferenças entre os controles e os 3xTg-AD. Para o estímulo periódico, a amplitude do 1º harmônico dos grupos com OP mostrou clara diferença entre os grupos controle e o 3xTg-AD, tanto em 12 Hz como em 18 Hz. Os resultados dos dois grupos controle b6;129 e C57/B6 mantiveram-se muito próximos. Os grupos sem OP mantiveram-se sempre próximos a 10 V para as três freqüências de estimulação e mostraram atraso na diferença de fase média do 1º harmônico em 18 e 30 Hz, indicando maior lentidão de resposta, quando comparados aos primeiros. Conclusão: O camundongo 3xTg-AD e seu controle (b6;129) apresentam uma variante lenta e sem OPs do ERG escotópico em parte da população. Células bipolares, amácrinas e ganglionares podem estar alteradas nesses subgrupos (b6;129 sem OP e 3xTg-AD sem OP). Os grupos controle e 3xTg-AD com OPs diferiram quanto à amplitude de resposta à estimulação intermitente, diferença essa que implica em menor capacidade de processamento temporal para o modelo de AD. Sugerimos que as células bipolares de cones podem estar alteradas nos modelos de AD devido às amplitudes mais baixas dos 1os harmônicos desse grupo / Objective: To evaluate electrophysiologically the function of the retina of the Alzheimer model mouse (3xTg-AD) comparing it with its control (b6;129-PS1) in a longitudinal study at six ages (2, 4, 6, 8, 10 e 12 months) Methods: Electroretinograms (ERGs) were recorded in 44 anesthetized mice 3xTg-AD and in 23 controls, with a contact lens electrode placed on the cornea, a reference electrode on the head and a ground on the tail. During a 30-40min duration session the mice were exposed to the following stimulation protocol: 1) Scotopic response Dark adaptation followed by flashes at the following intensities: 0,003; 0,03; 0,3; 3 e 30 cd.s/m2; 2) Periodic stimulation (30 cd.s/m2) at the temporal frequencies of 12, 18, e 30 Hz, under background light (30 cd/m2). Results: The ERGs showed two types of scotopic responses, which ocurred in both the control mice (b6;129- PS1) and the Alzheimer´s models (3xTg-AD). 13% of the controls and 72% of the Alzheimer´s models mice presented ERGs with oscillatory potentials (OPs) and b-wave implicit times within the expected range (45,31 ± 6,74 ms), while for the other groups the ERG presented a very delayed b-wave latency (111,73 ± 22,56 ms) and absence of OPs. Given these results, the control and experimental groups were subdivided into: b6;129 with OPs, b6;129 without OPs; 3xTg-AD with OPs e 3xTg-AD without OPs. An additional control group with 9 mice C57/B6 was included. Comparing the five groups, no difference was found in a-wave amplitude and latency. The b-wave amplitude also did not differ among the groups, but the latency of the b-wave for the groups b6;129 without OPs and 3xTg-AD without OPs, was twice as long as in the groups with OPs. The amplitudes of the five OPs, measured individually, did not show differences between controls and 3xTg-AD groups. For the periodic stimulation the amplitude of the first harmonic of the Fourier transform of the groups with OPs showed a clear difference between the control and the 3xTg-AD groups, both for the 12 Hz and for the 18 Hz stimuli. The results of the two control groups (b6;129 and C57/B6) were very close. The groups without OPs had responses always close to 10 V for the three frequencies of stimulation and showed phase delay for the first harmonic, indicating response slowing, compared to the other groups. Conclusions: We found that a sub-group of both triple transgenic (3xTg-AD) and control mice (b6;129) manifest strikingly slow scotopic ERGs that lack OPs. We hypothesize that these response feature may reflect alterations in bipolar, amacrine and ganglion cells. The sub-group of triple transgenic and control mice that exhibited OPs differed in their response to flicker. Alzheimer model had significantly lower flicker-response amplitudes than the controls, suggesting impaired retinal temporal processing. We propose that the flicker results are consistent with alteration in cone bipolar cells in the Alzheimer model mice
5

Estudo eletrofisiológico dos efeitos da injeção intravítrea de ácido micofenólico (mpa) na retina de coelhos

Aguiar, Renata Genaro 23 November 2011 (has links)
O presente trabalho utilizou o eletrorretinograma (ERG) em coelhos (Oryctolagus cuniculus) para avaliar uma forma alternativa de aplicação do ácido micofenólico no tratamento da uveíte, uma doença ocular inflamatória. Uveíte é o termo utilizado para definir a inflamação da íris, coróide e corpo ciliar. O ERG é um registro de potenciais elétricos originados na retina em resposta à estimulação luminosa. O objetivo desse estudo é analisar alterações em funções da retina em olhos tratados com diferentes doses intravítreas de ácido micofenólico. Foram medidas amplitude e latência das ondas a e b do ERG para a função de intensidade-resposta e de resolução temporal. O micofenolato de mofetila (MMF) é um potente medicamento imunossupressor e vem sendo empregado com sucesso no tratamento de uveítes. O MMF é uma pró-droga, que é transformada no fígado em ácido micofenólico (MPA), o imunossupressor ativo. O uso de MMF causa efeitos colaterais e, para diminuir esses efeitos, este estudo analisa a injeção intravítea de MPA em coelhos. Foram utilizados um total de quarenta animais, divididos em seis grupos. Primeiramente, foram realizados exames eletrorretinográficos em olhos intactos, sem administração de nenhuma substância, para determinação dos parâmetros dos registros. Foram testados também os olhos injetados apenas com solução salina balanceada (SSB). Após essa etapa, foram feitos testes com olhos injetados apenas com o veículo (Polissorbato 80). Esse procedimento foi necessário para estabelecer se o veículo pode ser utilizado ou se apresenta algum grau de toxicidade para a retina. As doses usadas para avaliação da toxicidade da droga foram cinco: 5 g/ml, 50 g/ml, 200 g/ml, 1.000 g/ml e 10.000 g/ml. Os exames eletrorretinográficos foram realizados 7 e 30 dias após injeção intravítrea de MPA. Os resultados indicam que não houve alteração nos parâmetros de ERG nos olhos que receberam apenas o veículo. Também não acusaram indícios de toxicidade os olhos tratados com as doses de 5, 50 e 200 g/ml da droga. Apenas com as doses mais altas, de 1.000 e 10.000 g/ml, os olhos apresentaram diminuição de sensibilidade ao estímulo luminoso. Não é possível afirmar que as células da retina não foram danificadas pela injeção intravítrea de MPA, pois o ERG de campo total não detecta lesões pontuais. O pequeno número de olhos analisados e a necessidade de utilização de anestésicos podem levar a interpretações equivocadas dos resultados. As substâncias anestésicas podem afetar a neurotransmissão e, consequentemente, os resultados obtidos nos registros do ERG. As análises dos dados de amplitude e tempo implícito das ondas a e b foram muito consistentes e apresentam variações compatíveis com a literatura / This work uses the application of the electroretinogram (ERG) in rabbits (Oryctolagus cuniculus) in order to evaluate an alternative way of using the mycophenolic acid for treatment of uveitis, an inflammatory eye disease. Uveitis is an inflammation of the iris, choroid and ciliary body. The ERG is the record of electrical responses originated in the retina to luminous stimulation. The purpose of this study is to analyse changes in the retinal functions of eyes treated with distinct intravitreous doses of mycophnolic acid. A and b waves amplitude and implicit times for the intensity-response and temporal resolution functions. Mofetil mycophenolate (MMF) is a powerful immunossupressant drug successfully used for treating the uveitis. It is a pro-drug that is transformed in the liver into mycophenolic acid (MPA), the active immunossupressor. MMF causes collateral effects and, in order to reduce these effects, the intravitreous MPA injection in rabbits is analysed in this study. Forty rabbits were used, divided in 6 groups. First of all, electroretinografic exams in control eyes were made, without the application of any substance, for determining the recording parameters. Then were tested the eyes injected with only balanced saline solution (BSS). After that, tests were made in eyes injected only with the vehicle (Polissorbato 80). This procedure was necessary for finding out whether the vehicle may be used or is in some degree toxic for the retina. The doses for evaluation of the drug toxicity were five: 5 g/ml, 50 g/ml, 200 g/ml, 1.000 g/ml e 10.000 g/ml. By the examination of the distinct parameters of the ERG, several visual functions can be evaluated (inner and outer retina) and possible impairments in the temporal resolution, in the relationship luminous intensity and amplitude of the response, and in other functions. The results show there were no changes in the ERG parameters for the eyes where only the vehicle was applied. Also, no toxicity signs were detected in 5, 50 or 200 g/ml doses. Sensitivity to the luminous stimulus was only shown in eyes treated with higher doses, or, 1.000 and 10.000 g/ml. It is not possible to assert that the retina cells were not injured by the MPA injection, as the total field ERG does not detect spot lesions. The small quantity of tested eyes and the usage of anesthetics may lead to erroneous interpretations of the results. The anesthetic substances can affect the neurotransmission and consequently the results of ERG records. The analysis of the a and b wave amplitude and implicit time were very consistent and show variations consistent with the pertinent literature
6

Eletrorretinograma de padrão reverso macular e multifocal e tomografia de coerência óptica em olhos suspeitos de glaucoma e glaucomatosos com perda de hemicampo / Macular and multifocal pattern electroretinogram and fourrier domain optical coherence tomography in glaucoma suspects and glaucomatous eyes with hemifield loss

Kreuz, André Carvalho 25 November 2016 (has links)
Objetivos: Avaliar a capacidade do eletrorretinograma de padrão reverso (PERG) macular e multifocal (mf) de diferenciar pacientes com suspeita de glaucoma (SG) e glaucoma com defeito de campo hemianópico (GH) de controles, comparar a capacidade de discriminação do PERG e tomografia de coerência óptica (TCO) fourrier domain, e avaliar a relação entre as medidas do PERG e TCO. Métodos: Medidas do campo visual (CV) computadorizado, respostas do PERG transiente e modo estacionário e PERGmf foram obtidos dos SG (n=14, 24 olhos), GH (n=5, 7 olhos) e controles (n=19, 22 olhos). Os seguintes parâmetros de TCO foram investigados: camada de fibras nervosas da retina peripapilar (CFNRpp), espessura total da mácula e espessuras das camadas segmentadas da mácula. As medidas foram analizadas utilizando-se modelos lineares de efeito misto. Também foi avaliada a relação entre as medidas e a performance diagnóstica de cada tecnologia. Resultados: Comparado aos controles, a média do tempo de pico de P50 da resposta do PERG transiente estava reduzida nos SG e GH, enquanto que a fase, a amplitude do modo estacionário e respostas do PERGmf estavam anormais apenas no GH. A média das medidas da TCO de espessura macular e da CFNRpp nos SG e GH diferiram significativamente dos controles. Uma significativa relação foi observada entre o PERG e a maior parte dos dos parâmetros do CV central e TCO. A análise por regressão e componentes principais revelou que a TCO de nervo óptico e mácula, assim como o PERG transiente e PERGmf tiveram estatisticamente capacidade similar em discriminar os SG dos controles. Conclusões: Os parâmetros do PERG e da TCO podem estar anormais, com significativa relação entre as medidas, em uma porcentagem alta de olhos com SG com CV normal. Nossos achados sugerem que as duas tecnologias podem ser úteis e complementares na detecção precoce de glaucoma / Purpose: To evaluate the ability of macular and multifocal (mf) pattern electroretinogram (PERG) to differentiate glaucoma suspects (GS) and glaucoma with hemifield loss (GHL) from controls, to compare the discrimination ability of PERG and fourier-domain optical coherence tomography (fdOCT), and to assess the relationship between PERG and fdOCT measurements. Methods: Standard automated perimetry (SAP), steady-state and transient PERG responses and mfPERG measurements were obtained from GS (n=14, 24 eyes), GHL (n=5, 7 eyes) and controls (n=19, 22 eyes). The following fdOCT parameters were investigated: circumpapillary retinal nerve fiber layer (cpRNFL), full-thickness macula, and segmented macular layer thicknesses. Measurements were compared using mixed effects linear models. The relationships between measurements and the diagnostic performance of each technology were also assessed. Results: Compared to controls, average P50 peak time transient PERG responses were reduced in GS and GHL, whereas average phase and amplitude steady-state and mfPERG responses were abnormal only in GHL. The average fdOCT-measured cpRNFL and macular thickness measurements in GS and GHL differed significantly from controls. A significant relationship was found between PERG and most fdOCT or central SAP sensitivity parameters. Principal component regression analysis revealed that optic disc and macular OCT parameters, along with mfPERG and transient PERG parameters had statistically similar ability to discriminate GS from controls. Conclusions: PERG and OCT parameters may be abnormal, with significant correlations between measurements, in a high percentage of GS eyes with normal SAP. Our findings suggest that both technologies may be helpful and complementary in early glaucoma detection
7

Perdas de função visual na distrofia muscular de Duchenne: visão de cores e visão de contrastes de luminância temporal e espacial / Visual function losses in Duchenne musculas dystrophy: color vision and spatial and temporal luminance contrast vision

Costa, Marcelo Fernandes da 23 August 2004 (has links)
A Distrofia Muscular de Duchenne (DMD) é uma doença recessiva ligada ao cromossomo X, causada por deleção ou mutação na proteína distrofina, e afeta 1 para cada 3.500 nascidos vivos do sexo masculino. O gene da distrofina é o maior gene do genoma humano e, além das proteínas de tamanho total, ao menos outras 5 isoformas foram identificadas até o momento. A isoforma total da distrofina e outras menores como a Dp260 (transcrita pelo promotor localizado no exon 30; encontrada na camada plexiforme externa da retina) e Dp71 (transcrita pelo promotor localizado no exon 63; encontrada nas células de Muller e membrana limitante interna da retina) são expressas na retina, dentre vários tecidos do corpo. Alterações nos eletrorretinogramas (ERG) de sujeitos com DMD já foram descritas na literatura. Redução da amplitude da onda-b e ERG negativo (razão das.amplitudes entre as ondas b e a menor que 1) são os achados mais comuns principalmente em sujeitos com deleção posterior ao exon 30. Embora estas alterações sejam conhecidas, poucos estudos avaliaram funcionalmente a visão destes sujeitos e, estes concluíram que os sujeitos com DMD apresentam visão de cores, acuidade visual e motilidade ocular normais. Como estas conclusões não refletem os achados eletrofisiológicos, o presente trabalho teve por objetivo aprofundar a avaliação de funções visuais em sujeitos com DMD, utilizando testes psicofisicos mais precisos e sensíveis que os métodos anteriormente empregados. Aplicamos uma bateria de testes que avaliou: a visão de cores (Cambridge Colour Test, Anomaloscópio de Neitz tipo I, lshihara e AO H-R-R) e a sensibilidade ao contraste de luminância (espacial e temporal), em 54 meninos (idade média =14,2 ± 4,1) com DMD, bem como o ERG em um subgrupo de 11 sujeitos. De acordo com a região da deleção no gene foram constituídos 3 grupos: grupo 1 (n=20) - sem deleção, grupo 2 (n=7) - com deleção anterior ao exon 30, grupo 3 (n=27) com deleção posterior ao exon 30. O grupo controle foi composto por 35 meninos com idade equiparada (médias = 15,4 ± 3,9). Os resultados mostraram que 52% dos sujeitos do grupo 3 apresentam defeitos de visão de cores. Surpreendentemente, a maioria destes sujeitos apresentou um defeito no eixo protan-deutan. Os três grupos apresentaram redução na sensibilidade ao contraste espacial e ao contraste temporal para todas as freqüências espaciais e temporais testadas. Houve uma tendência do grupo 3 de ter os piores resultados de contraste espacial. Para os resultados de contraste temporal, diferiram estatisticamente do grupo controle apenas os sujeitos do grupo 3 que tinham defeito de visão de cores. Os parâmetros do ERG de campo total replicaram os dados da literatura mostrando uma diminuição da amplitude e um aumento da latência da onda-b, além de uma razão b/a menor que l. A análise individual dos potenciais oscilatórios mostrou redução significante no 3° e no 4° potenciais, indicando que tanto a via dos cones quanto a dos bastonetes estão afetadas nos sujeitos com.DMD e deleção posterior ao exon 30. A constatação das maiores alterações de função visual nos sujeitos com deleção posterior ao exon 30 leva a sugerir que a distrofina Dp260 tem papel importante na fisiologia retiniana. Em conclusão, o presente trabalho demonstrou que a DMD é acompanhada por perdas visuais em várias funções e que estas perdas podem ser causadas principalmente por modificações na isoforma Dp260 da distrofina / Duchenne muscular dystrophy (DMD) is an X-linked recessive disorder, caused by deletion or mutation in the protein dystrophyn, which affects 1:3500 live male births. The dystrophyn gene is the largest gene in the human genome. The full-length dystrophyn and at least other 5 isoforms have been identified. They are expressed in several tissues of the body including the retina, where the shorter isoforms Dp260 (transcribed by a promoter at the exon 30; founded in the outer plexiform layer of the retina) and Dp71 (transcribed by a promoter at the exon 63; founded in the Muller cells and inner limiting membrane of the retina) have been shown. Alterations in the electroretinograms (ERG) of these subjects have been described in the literature. 13-wave amplitude reduction and -a negative ERG (b/a wave amplitude ratio < 1) are the most common alterations found in subjects with gene deletion downstream exon 30, transcribes Dp260 isoform. Although these alterations are known, the only study that performed 1 evaluations of visual functions in these subjects concluded that they showed normal color vision, visual acuity and ocular motility results. Since these conclusions do not reflect the electrophysiological findings the objective of the present study was to further evaluate the visual function of DMD subjects using more sensitive and precise psychophysical tests than the methods used before. A battery of visual tests was used to evaluate color vision (Cambridge Colour Test, Neitz-1 Anomaloscope, Ishihara and AO H-R-R), luminance contrast sensitivity (spatial and temporal) in 54 boys (mean age = 14,2 ± 4,1) with DMD, and the ERG was also measured in a subgroup (n = 11) of these boys. According with the region of gene deletion, the subjects were divided in 3 groups: group 1 (n = 20) - without gene deletion, group 2 (n = 7) - with gene deletion upstream exon 30, group 3 (n = 27) - with gene deletion downstream exon 30. The control group was composed of 35 age-matched boys (mean-- 15,4 ± 3,9). Our results showed that 52% of the group 3 subjects had color vision defects. Surprisingly, almost all of these boys had a defect in the proten-deutan axis. In all three groups, spatial and temporal contrast sensitivities were lower than those of controls, for all spatial and temporal frequencies tested. Group 3 subjects had a tendency not statistically significant to present the worst results of spatial contrast sensitivities. Temporal contrast sensitivities were significantly different from controls' only for group 3 subjects with color vision defects. The full-field ERG results showed a b-wave amplitude reduction, a longer implicit time and a b/a ratio less than 1. Oscillatory potentials were significantly lower in the 3° and 4° potentials suggesting that that both cone and rod pathways were affected in the DMD subjects with deletion downstream exon 30. To our knowledge there are no descriptions of visual function defects in DMD subjects. The finding that the largest alterationslosses of visual function oceur in the subjects with deletion downstream exon 30 leads us to suggest that the dystrophyn Dp260 has an important role in the physiology of the retina physiology. In conclusion, the present study showed that DMD is accompanied losses in several visual functions and that these losses may be caused mainly by impairment in the Dp260 dystrophyn isoform
8

Avaliação das vias do sistema visual por eletrorretinograma e testes psicofísicos na Distrofia Muscular de Duchenne e na Diabetes Mellitus tipo 1 / Visual system pathways evaluation by electroretinogram and psychophysical test in Duchenne Muscular Dystrophy and Type 1 Diabetes Mellitus

Martins, Cristiane Maria Gomes 26 September 2017 (has links)
A retina é formada por camadas de células que a estrutura, os contatos sinápticos e as características fisiológicas são específicas para cada tipo de célula. O processamento da informação visual, após a ativação dos fotorreceptores pela luz, ocorre em mecanismos pós-receptorais que formam diferentes circuitos de processamento, entre eles as vias ON, OFF, de luminância e de oponência cromática. As doenças que afetam a retina podem estar relacionadas com alterações específicas de um determinado circuito, como acontece com a distrofia muscular de Duchenne (DMD) que na alteração do gene dmd da retina afeta a comunicação entre os fotorreceptores e as células bipolares, e na diabetes Mellitus (DM) o dano celular ocorre principalmente na camada mais interna da retina. O objetivo deste estudo foi avaliar os efeitos da DMD e da diabetes Mellitus Tipo 1 (DM1) em diferentes mecanismos visuais. A amostra deste trabalho contou com três grupos: controle com 18 participantes (13,5, ±7,6), DMD com 9 participantes (16, ±5,9) e DM1 com 12 partcipantes (13,8, ±2,5). Os testes eletrorretinográficos foram aplicados nas condições mesópica, fotópica com estímulos que enfatizam respostas ON ou OFF, e flicker heterocromático (verde-vermelho) em 12Hz (para enfatizar a atividade da via de oponência cromática) e 36Hz (para enfatizar a atividade da via de luminância), e testes psicofísicos com estímulos que enfatizam os mecanismos ON e OFF com contraste de luminância e a via de oponência cromática por um estímulo com contraste cromático (isoluminante) verde-vermelho. O grupo DMD apresentou alteração no tempo de resposta e redução na amplitude da onda-a e onda-b nas condições mesópicas ON e OFF, redução da amplitude da onda-b na condição fotópica ON e alteração da via cromática. Enquanto o grupo DM1 apresentou aumento na amplitude e tempo da ond-a e onda-b das via ON e OFF na condição mesópica, mudança na fase da resposta na via cromática e na via de luminância. Os resultados estão de acordo com diversos estudos anteriores que mostram que as duas doenças causam alterações funcionais na retina, mas cada doença com características específicas. O presente estudo demonstrou que as duas doenças afetam as vias visuais ON e OFF independente do prejuízo neural ocorrer principalmente nas camadas mais externas ou nas camadas mais internas da retina. A possibilidade de identificar prejuízos funcionais em pacientes sem alteração clínica é uma valiosa ferramenta para o acompanhamento de doenças e para avaliar a eficácia de tratamentos. O presente estudo poderá contribuir para o estabelecimento de novos protocolos mais sensíveis e capazes de identificar alterações assimétricas no caso da DMD ou alterações que precedem o diagnóstico clínico no caso da DM1 / The retina is formed by layers of cells that the structure, synaptic contact and physiology characters are specific for each type of this cells. The processing of visual information, after the photoreceptor activation by light is separate by post-receptor mechanisms that constitute the ON, OFF, luminance and chromatic pathways. The retina diseases have specific alteration in this tissue, thus it happens with the Duchenne muscular dystrophy (DMD), that have communication problems among photoreceptors and bipolar cells because of damage in dmd gene, and the Diabetes Mellitus (DM) that has cells damage mainly in the inner layer of retina. The purpose of this study was to evaluate the effects of DMD and Type 1 diabetes Mellitus (DM1) on different visual mechanisms. The sample had three grups: control with 18 subjects (13.5, ±7.6), DMD with 9 subjects (16, ±5.9) and DM1 with 12 subjects (13,8, ±2,5). The ERG recordings were applied in of the mesopic and photopic conditions with stimuli that laid emphasis on ON and OFF responses and heterochromatic (red-green) flicker modulation in 12Hz (laid emphasis on chromatic pathway) and 36Hz (laid emphasis on luminance pathway), and psychophysical tests laid emphasis on ON and OFF mechanisms with luminance contrast and the chromatic opponent pathway by stimulus with red-green chromatic contrast (isoluminance). As a result the DMD group presented alteration in the response time and reduction in the amplitude of the a- and b-wave in ON and OFF mesopic conditions, reduction of the amplitude of the a- and b-wave in ON photopic condition and alteration of the chromatic pathway. While the DM1 group showed an increase in the amplitude and time of the a- and b-wave in ON and OFF pathways of the mesopic condition, change in phase of the chromatic pathway and luminance pathway. These results were in agreement with previous studies that showed the two diseases present functional changes in the retina, but each disease with specific characteristics. The present study showed that two diseases affect the ON and OFF pathways regardless of the neural damage occur mainly in outer layer or inner layer of the retina. The possibility identify functional damage in patients without clinic injuries is the valuable tool for the following the dieses and evaluated treatment efficiency. The present study may contribute to establishment of the new sensitive and able protocols to identify asymmetric changes in DMD or changes that precede the clinical diagnosis in DM1
9

Avalia??o da resposta cl?nica eletrorretinogr?fica de equinos frente ? utiliza??o de diferentes tipos de eletrodos e tr?s protocolos de seda??o / Clinical evaluation of equines electroretinografic responses, between two different electrodes and four sedation protocols

Rosa, Maurilio 24 July 2009 (has links)
Made available in DSpace on 2016-04-28T20:18:33Z (GMT). No. of bitstreams: 1 2009 - Maurilia Rosa.pdf: 1267730 bytes, checksum: 83f63cab4df91abac0ab57c414b16bd6 (MD5) Previous issue date: 2009-07-24 / Ocular eye and adnexa examination is a routine in Veterinary practice. Diagnostic and treat diseases that affect domestic animals site is the main goal of these procedures. The importance of this research was the electrophysiology study of equine retina thru an FullField ERG examination in standing horses intravenouslly sedated, with auriculopalpebral nerve block and corneal topical anesthesia. Protocols and procedures used in clinical ERG were according International Society of Clinical Electrophysiology of Vision (ISCEV) standards. In this study, forty healthy horses were evaluated by FullField ERG. In the present study, 15 males and 25 mares, aging between 2 months to 18 years (m?dian age 4,6 years). Horses were randomly allocated into eight groups according sedative drugs as Xylazine, Romifidine, Detomidine, Medetomidine and corneal electrode ERG-Jet Electrode (ERG-jet), Dowson Trick Litzkow (DTL-plus) types. Group 1 was GXDTL, Group 2 GDDTL, Group 3 GRDTL, Group 4 GMDTL, Group 5 GXERG, Group 6 GDERG, Group7 GRERG, and Group 8 GMERG. In all groups a-b complex amplitude and implicit times were investigated and compared for both eyes. Quality and costs of sedation drugs were estimated. This research leads to the conclusion that was differences between corneal electrodes and ERG-jet showed safer and more practical during ERG examination. There were no difference between drugs sedation effect but Detomidine and Medetomidine showed better results to promote sedation during examination than Romifidine and Xylazine. The sedation protocol using Romifidine showed the lowest cost. / O exame oft?lmico ? uma pr?tica rotineira na Medicina Veterin?ria que objetiva identificar e tratar as afec??es do globo ocular e anexos dos animais dom?sticos. Neste trabalho estudamos a eletrofisiologia da vis?o do eq?ino, atrav?s do exame de eletrorretinografia de campo total, com o uso de seda??o e bloqueio anest?sico, com o animal na posi??o quadr?pede. Para execu??o dos exames, estabeleceu-se um protocolo b?sico de acordo com as normas e recomenda??es do International Society for Clinical Eletrophysiology of Vision (ISCEV), Foram avaliados 40 equinos considerados normais ap?s exame oft?lmico, sendo 15 machos e 25 f?meas, com idade variando entre dois meses a 18 anos (m?dia de 4,6 anos) pelo de exame de Eletrorreninografia de Campo Total e na posi??o qudr?pede. Os animais foram divididos em oito grupos em fun??o do f?rmaco sedativo (Xilazina, Romifidina, Detomidina e Medetomidina), e do tipo de eletrodo utilizados ERG - Jet Electrode (ERG-Jet) e Dowson Trick Litzkow (DTL). Foram ent?o assim denominados; o Grupo 1: GXDTL, Grupo 2: GDDTL, Grupo3: GRDTL, Grupo4: GMDTL, Grupo5: GXERG, Grupo 6: GDERG, Grupo 7: GRERG e o Grupo 8: GMERG. Em todos os grupos mensuraram-se os valores das amplitudes de pico das ondas a e b , seus implicit time , para os olhos direito e esquerdo. Tamb?m foram avaliados o tempo, a qualidade e o custo da seda??o. Conclu?mos que houve diferen?a entre os eletrodos avaliados, e que o eletrodo ERG-jet mostrou-se mais adequado em raz?o da sua seguran?a e praticidade de utiliza??o. As drogas estudadas n?o diferiram entre si quanto aos resultados do eletrorretinograma, por?m a Detomidina e Medetomidina apresentaram um desempenho superior em rela??o ? Romifidina e ? Xilazina na efici?ncia de conten??o e facilita??o do exame. A seda??o com Romifidina foi a que representou menor custo de execu??o.
10

Eletrorretinograma de padrão reverso macular e multifocal e tomografia de coerência óptica em olhos suspeitos de glaucoma e glaucomatosos com perda de hemicampo / Macular and multifocal pattern electroretinogram and fourrier domain optical coherence tomography in glaucoma suspects and glaucomatous eyes with hemifield loss

André Carvalho Kreuz 25 November 2016 (has links)
Objetivos: Avaliar a capacidade do eletrorretinograma de padrão reverso (PERG) macular e multifocal (mf) de diferenciar pacientes com suspeita de glaucoma (SG) e glaucoma com defeito de campo hemianópico (GH) de controles, comparar a capacidade de discriminação do PERG e tomografia de coerência óptica (TCO) fourrier domain, e avaliar a relação entre as medidas do PERG e TCO. Métodos: Medidas do campo visual (CV) computadorizado, respostas do PERG transiente e modo estacionário e PERGmf foram obtidos dos SG (n=14, 24 olhos), GH (n=5, 7 olhos) e controles (n=19, 22 olhos). Os seguintes parâmetros de TCO foram investigados: camada de fibras nervosas da retina peripapilar (CFNRpp), espessura total da mácula e espessuras das camadas segmentadas da mácula. As medidas foram analizadas utilizando-se modelos lineares de efeito misto. Também foi avaliada a relação entre as medidas e a performance diagnóstica de cada tecnologia. Resultados: Comparado aos controles, a média do tempo de pico de P50 da resposta do PERG transiente estava reduzida nos SG e GH, enquanto que a fase, a amplitude do modo estacionário e respostas do PERGmf estavam anormais apenas no GH. A média das medidas da TCO de espessura macular e da CFNRpp nos SG e GH diferiram significativamente dos controles. Uma significativa relação foi observada entre o PERG e a maior parte dos dos parâmetros do CV central e TCO. A análise por regressão e componentes principais revelou que a TCO de nervo óptico e mácula, assim como o PERG transiente e PERGmf tiveram estatisticamente capacidade similar em discriminar os SG dos controles. Conclusões: Os parâmetros do PERG e da TCO podem estar anormais, com significativa relação entre as medidas, em uma porcentagem alta de olhos com SG com CV normal. Nossos achados sugerem que as duas tecnologias podem ser úteis e complementares na detecção precoce de glaucoma / Purpose: To evaluate the ability of macular and multifocal (mf) pattern electroretinogram (PERG) to differentiate glaucoma suspects (GS) and glaucoma with hemifield loss (GHL) from controls, to compare the discrimination ability of PERG and fourier-domain optical coherence tomography (fdOCT), and to assess the relationship between PERG and fdOCT measurements. Methods: Standard automated perimetry (SAP), steady-state and transient PERG responses and mfPERG measurements were obtained from GS (n=14, 24 eyes), GHL (n=5, 7 eyes) and controls (n=19, 22 eyes). The following fdOCT parameters were investigated: circumpapillary retinal nerve fiber layer (cpRNFL), full-thickness macula, and segmented macular layer thicknesses. Measurements were compared using mixed effects linear models. The relationships between measurements and the diagnostic performance of each technology were also assessed. Results: Compared to controls, average P50 peak time transient PERG responses were reduced in GS and GHL, whereas average phase and amplitude steady-state and mfPERG responses were abnormal only in GHL. The average fdOCT-measured cpRNFL and macular thickness measurements in GS and GHL differed significantly from controls. A significant relationship was found between PERG and most fdOCT or central SAP sensitivity parameters. Principal component regression analysis revealed that optic disc and macular OCT parameters, along with mfPERG and transient PERG parameters had statistically similar ability to discriminate GS from controls. Conclusions: PERG and OCT parameters may be abnormal, with significant correlations between measurements, in a high percentage of GS eyes with normal SAP. Our findings suggest that both technologies may be helpful and complementary in early glaucoma detection

Page generated in 0.4604 seconds