• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 200
  • 64
  • 57
  • 18
  • 12
  • 11
  • 6
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 3
  • Tagged with
  • 435
  • 435
  • 406
  • 112
  • 103
  • 95
  • 64
  • 63
  • 62
  • 61
  • 54
  • 53
  • 49
  • 45
  • 42
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
161

Connectivité fonctionnelle au repos : relation avec la topographie et la propagation des atteintes structurales, fonctionnelles et moléculaires dans la maladie d'Alzheimer / Resting-state functional connectivity : relationships with topography and propagation of structural, functional and molecular disruptions in Alzheimer’s disease

Mutlu, Justine 29 May 2017 (has links)
L’amélioration des techniques d’imagerie cérébrale a permis de grandes avancées dans la compréhension et la prédiction des mécanismes physiopathologiques de la Maladie d’Alzheimer (MA). Récemment, des travaux ont émis l’hypothèse d’une neurodégénérescence transneuronale selon laquelle les maladies neurodégénératives cibleraient des réseaux fonctionnels spécifiques où elles apparaitraient et se propageraient. Cette thèse visait à tester cette hypothèse dans le cadre de la MA en étudiant les liens entre la connectivité fonctionnelle au repos et les atteintes structurales, métaboliques et moléculaires. Un premier volet a été consacré à la caractérisation des atteintes fonctionnelles, structurales et métaboliques au sein des réseaux ventral et dorsal du cortex cingulaire postérieur (CCP) dans le Mild Cognitive Impairment (MCI) et la MA. Cette étude transversale a suggéré une vulnérabilité plus précoce (dès le stade de MCI) du réseau ventral en atrophie et en connectivité fonctionnelle au repos tandis que l’hypométabolisme était présent dans les deux réseaux chez les MCI et les MA. Le second volet a permis d’évaluer l’influence de la connectivité spécifique (de la région la plus atteinte) versus de la connectivité globale (d’une région avec le reste du cerveau, particulièrement élevée dans les régions hubs) sur la topographie et la propagation de l’atrophie, de l’hypométabolisme et des dépôts amyloïdes sur 18 mois dans la MA. Cette étude longitudinale a révélé que l’atrophie apparaitrait et se propagerait via la connectivité spécifique en évitant les régions hubs qui sont davantage vulnérables à l’hypométabolisme et aux dépôts amyloïdes. / Advances in neuroimaging techniques have allowed considerable improvement of the understanding and the prediction of the pathophysiological processes of Alzheimer’s disease (AD). Recent findings suggested a transneuronal spread hypothesis of neurodegeneration according to which neurodegenerative disease would target specific functional networks among which it would appear and spread. This thesis aimed at assessing this hypothesis in AD by studying the relationships between resting-state functional connectivity and structural, metabolic and molecular alterations. Firstly, we identified the functional, structural and metabolic alterations within the ventral and the dorsal posterior cingulate cortex (PCC) networks in Mild Cognitive Impairment (MCI) and AD. This transversal study suggested an early vulnerability (since the MCI stage) of the ventral network regarding atrophy and resting-state functional connectivity disruptions while hypometabolism concerned both ventral and dorsal networks in MCI and AD patients. Secondly, we assessed the relative influence of the specific connectivity (of the region the most disrupted) versus the global connectivity (of one region with the rest of the brain, especially high in hub regions) on the topography and the propagation of atrophy, hypometabolism and amyloid deposition over 18 months in AD. This longitudinal study revealed that atrophy would appear and propagate through the specific connectivity by avoiding hub regions which would be more vulnerable to the hypometabolism and amyloid deposition.
162

Engraftment of Pancreatic Islets in Alternative Transplantation Sites and the Feasibility of in vivo Monitoring of Native and Transplanted Beta-Cell Mass

Espes, Daniel January 2016 (has links)
Islet transplantation is a possible curative treatment for type 1 diabetes (T1D). Currently the liver dominates as implantation site, despite the many challenges encountered at this site. Acute hypoxia in islets transplanted to muscle and omentum, two possible alternative sites, was prevailing. However, it was rapidly reversed at both implantation sites, in contrast to when islets were transplanted intraportally. At the intramuscular site hypoxia was further relieved by co-transplantation of an oxygen carrier, polymerized hemoglobin, which also improved the functional outcome. The complement system was activated after islet transplantation to muscle, but did not hamper graft function. Both mouse and human islets transplanted to omentum become well re-vascularized and have a functional blood flow and oxygenation comparable with that of endogenous islets. Animals transplanted with islets to the omentum had a superior graft function compared with animals receiving intraportal islet grafts. Alloxan-diabetic animals were cured with a low number of islets both when the islets were implanted in the omentum and muscle. The islet grafts responded adequately to both glucose and insulin and displayed a favorable mRNA gene expression profile. A challenge in diabetes research and in islet transplantation is that there are no established techniques for quantifying beta-cell mass in vivo. By using radiolabeled Exendin-4, a GLP-1 receptor agonist, beta-cell mass after transplantation to muscle of mice was quantified. The results may well be translated to the clinical setting. By comparing the pancreatic accumulation of [11C]5-hydroxy tryptophan ([11C]5-HTP) as detected by positron emission tomography (PET) in T1D patients with that of healthy controls, a 66% decrease was observed. This may in fact represent the loss of beta-cells, taking into account that other cells within the islets of Langerhans are largely unaffected in T1D.  In conclusion, the data presented support the use of alternative implantation sites for islet transplantation. In addition to improving the functional outcome this may enable more transplantations since the number of transplanted islets may be reduced. The techniques investigated for quantifying transplanted and endogenous beta-cell mass may greatly improve our knowledge of the pathophysiology of T1D and become a valuable tool for evaluation of beta-cell mass.
163

Προσομοίωση σχηματισμού εικόνας συστημάτων πυρηνικής ιατρικής με μεθόδους Monte Carlo / Simulation of image formation in nuclear medicine imaging systems using Monte Carlo methods

Καρπέτας, Γεώργιος 11 October 2013 (has links)
Ο γενικός σκοπός της παρούσας μελέτης ήταν να προτείνει μια νέα μέθοδο για την πλήρη περιγραφή των χαρακτηριστικών ποιότητας εικόνας και την βελτιστοποίηση της Τομογραφίας Εκπομπής Ποζιτρονίων (PET) αναπτύσσοντας ένα μοντέλο Monte Carlo. Υλικά και Μέθοδοι: Η μέθοδος αναπτύχθηκε χρησιμοποιώντας τον κώδικα Monte Carlo (GEANT4 Application For Tomographic Emissions) του GEANT4 με το πακέτο λογισμικού GATE που αναπτύχθηκε από την Open-GATE collaboration. Για την ανακατασκευή των εικόνων χρησιμοποιήθηκε το λογισμικό STIR και για τη λήψη των δεδομένων της ανακατασκευής, από το GATE, χρησιμοποιήθηκε μια συστοιχία από 12 επεξεργαστές Dual Core Intel (R) Xeon (TM) 3.00GHz (Supermicro SuperServer 6015B-UR/NTR, Αγγλία). Ο σαρωτής PET που προσομοιώθηκε σε αυτή τη μελέτη ήταν ο General Electric Discovery-ST (ΗΠΑ). Το μοντέλο GATE πιστοποιήθηκε μέσω της σύγκρισης των αποτελεσμάτων που ελήφθησαν με δημοσιευμένα αποτελέσματα (Bettinardi et al 2004, Mawlawi et al 2004) τα οποία ακολουθούν το πρωτόκολλο της NEMA-NU-2 2001. Οι εικόνες ανακατασκευάστηκαν με τρεις μεθόδους, αρχικά με τη 2D φιλτραρισμένη οπισθοπροβολή (FBP2D), στη συνέχεια με τη μέθοδο της 3D φιλτραρισμένης οπισθοπροβολής (FPB3DRP), των Kinahan και Rogers, και τέλος με χρήση επαναληπτικών αλγορίθμων (MLE-OSMAPOSL). Αρχικά έγινε προσδιορισμός της Συνάρτησης Μεταφοράς Διαμόρφωσης (MTF) για την αξιολόγηση της ποιότητας εικόνας συστημάτων PET. Η αξιολόγηση έγινε μέσω της προσομοίωσης μιας νέας επίπεδης πηγής Λεπτού Χρωματογραφικού Φιλμ (Thin Layer Chromatography-TLC) το οποίο αποτελείται από ένα στρώμα Διοξειδίου του Πυριτίου και υποστρώματα φύλλου Αλουμινίου, εμβαπτισμένο σε 18F-FDG με ενεργότητα 44.4MBq. Η αξιολόγηση της MTF έγινε μέσω των ανακατασκευασμένων εικόνων της επίπεδης πηγής κάνοντας χρήση του λογισμικού STIR. Η αξιολόγηση της MTF πραγματοποιήθηκε επίσης: α) σε τρεις διαστάσεις (3D), τοποθετώντας την επίπεδη πηγή σε οριζόντια και σε κάθετη κατεύθυνση (διαστάσεις πηγής οριζόντια και κάθετα 5x10 εκατοστά), β) με σάρωση πηγής μεγαλύτερου πλάτους, ανακατασκευάζοντας την εγκάρσια τομή της (διαστάσεις 18x10cm) και γ) από ανακατασκευασμένες εικόνες σημειακής πηγής. Να τονίσουμε εδώ ότι η παρούσα μελέτη είχε ως στόχο να συγκρίνει την προτεινόμενη μέθοδο (αξιολόγηση της MTF μέσω επίπεδης πηγής) με την πιο παραδοσιακή τεχνική που βασίζεται σε σημειακές πηγές. Στη συνέχεια έγινε προσδιορισμός της Ανιχνευτικής Κβαντικής Αποδοτικότητας (DQE) για την εκτίμηση της συνολικής απόδοσης του συστήματος PET, μέσω υπολογισμού της Συνάρτησης Μεταφοράς Διαμόρφωσης και του Κανονικοποιημένου Φάσματος Ισχύος Θορύβου (NNPS). Οι καμπύλες της MTF υπολογίστηκαν από την ανακατασκευή των εγκάρσιων τομών της επίπεδης πηγής (1 MBq), ενώ το NNPS υπολογίστηκε από τις αντίστοιχες στεφανιαίες τομές. Οι εικόνες ανακατασκευάστηκαν εφαρμόζοντας επαναληπτικούς αλγόριθμους (MLE-OSMAPOSL), χρησιμοποιώντας διάφορα υποσύνολα των προβολών (subsets) (3 έως 21) και επαναλήψεων (iterations) (1 έως 20). Επιπλέον, η αξιολόγηση της DQE έγινε μέσω διερεύνησης της επίδρασης διαφόρων κρυστάλλων σπινθηριστών στην διακριτική ικανότητα (MTF) και τον θόρυβο (NNPS) των ανακατασκευασμένων εικόνων του PET. Σε αυτή την περίπτωση, ο αλγόριθμος ανακατασκευής της εικόνας MLE-OSMAPOSL, υλοποιήθηκε χρησιμοποιώντας 15 subsets και 3 iterations. Αποτελέσματα και Συζήτηση: Τα αποτελέσματα της πιστοποίησης μέσω σύγκρισης με δημοσιευμένα αποτελέσματα είναι τα ακόλουθα: Η Διακριτική Ικανότητα (Spatial Resolution, SR) στο Πλήρες Εύρος στο Ήμιση του Μέγιστου (Full Width at Half Maximum - FWHM) βρέθηκε να έχει απόκλιση μικρότερη από 3,29% σε λειτουργία 2D και μικρότερη από 2,51% σε λειτουργία 3D, σε σχέση με δημοσιευμένα πειραματικά αποτελέσματα (Mawlawi et al 2004), αντιστοίχως. Οι τιμές 2D, για την Ευαισθησία (Sensitivity), το Ποσοστό Σκέδασης (Scatter Fraction-SF) και την Απόδοση του Ρυθμού Μέτρησης (Count-Rate), τα οποία ελήφθησαν ακολουθώντας το πρωτόκολλο της NEMA NU 2-2001, βρέθηκαν να διαφέρουν λιγότερο από 0,46%, 4,59% και 7,86%, αντίστοιχα με τα δημοσιευμένα πειραματικά αποτελέσματα (Mawlawi et al 2004). Ακολούθως, οι αντίστοιχες τιμές σε λειτουργία 3D βρέθηκαν να διαφέρουν λιγότερο από 1,62%, 2,85% και 9,13%, αντίστοιχα, με τα δημοσιευμένα πειραματικά αποτελέσματα (Mawlawi et al 2004). Η ευαισθησία επιπλέον εκτιμήθηκε χωρίς την παρουσία υλικού εξασθένησης, προσομοιώνοντας απευθείας μια ιδανική πηγή. Οι διαφορές που προέκυψαν μεταξύ της ιδανικής πηγής και της μεθοδολογίας κατά NEMA-NU-2 2001 κυμαίνονται από 0,04% έως 0,82% (ακτινική θέση R = 0cm) σε λειτουργία 2D και από 0,52% έως 0,67% σε λειτουργία 3D (ακτινικές θέσεις R = 10cm). Συνεπώς κάνοντας χρήση αυτής της μεθόδου, η ευαισθησία μπορεί να προσδιοριστεί με πιο απλοποιημένη και γρήγορη διαδικασία. Οι τιμές του Ρυθμού Μέτρησης Ισοδύναμου Θορύβου (Noise Equivalent Count Rate-NECR) που προέκυψαν ήταν 94.31kcps σε 2D και 66.9kcps σε 3D στα 70 και 15kBq/mL αντίστοιχα, σε σύγκριση με τα δημοσιευμένα αποτελέσματα τα οποία ήταν 94.08kcps σε 2D και 70.88kcps σε 3D στα 54.6kBq/mL και 14kBq/mL αντίστοιχα. Οι τιμές για την ποιότητα εικόνας βρέθηκαν σε εξαιρετική συμφωνία με τα δημοσιευμένα αποτελέσματα. Αφού ολοκληρώθηκε η πιστοποίηση του μοντέλου έγινε υπολογισμός της MTF. Οι τιμές MTF που προέκυψαν από την ανακατασκευή με τον αλγόριθμο FBP2D βρέθηκαν σε εξαιρετική συμφωνία με αυτές που προέκυψαν από την ανακατασκευή με τον αλγόριθμο FBP3DRP, ενώ οι αντίστοιχες τιμές μέσω του αλγόριθμου MLE-OSMAPOSL ήταν σε όλο το φάσμα των χωρικών συχνοτήτων υψηλότερες σε σχέση με τους αλγόριθμους οπισθοπροβολής (FBP). Η προσομοίωση της μεγάλης επίπεδης πηγής με αλγορίθμους οπισθοπροβολής έδειξε ότι οι τιμές της MTF ελαττώνονται σταδιακά από το κέντρο προς τα άκρα του οπτικού πεδίου (Field Of View-FOV). H MTF, της κάθετης τομής, διέφερε ελάχιστα σε σχέση με την οριζόντια. Η σύγκριση της επίπεδης πηγής με τη σημειακή πηγή έδειξε ότι η πρώτη είναι λιγότερη ευαίσθητη στο θόρυβο (SD = 0,0031 και 0,0203, αντίστοιχα). Η αξιολόγηση της DQE μέσω επαναληπτικών αλγορίθμων MLE-OSMAPOSL έδειξε ότι η απόδοση του συστήματος βελτιώνεται όσο αυξάνεται ο αριθμός των επαναλήψεων μέχρι μια μέγιστη τιμή (12 iterations) και παρέμενε αναλλοίωτη από εκεί και έπειτα. Επιπλέον, η μεταβολή του αριθμού των subsets δεν είχε επίδραση στην MTF, για ίσο αριθμό επαναλήψεων. Αντίστοιχα τα επίπεδα θορύβου (NNPS) μειώθηκαν με την αύξηση του αριθμού των iterations και των subsets. Με βάση τα προηγούμενα οι τιμές της DQE επηρεάστηκαν τόσο από την MTF όσο και από το NNPS και βρέθηκαν να αυξάνουν με την αντίστοιχη αύξηση του αριθμού των iterations και των subsets. Τέλος, ο ανιχνευτής PET στον οποίο τοποθετήθηκαν κρύσταλλοι LuAP, παρείχε τις βέλτιστες τιμές MTF σε οπισθοπροβολή 2D και 3D ενώ η αντίστοιχη διαμόρφωση με κρυστάλλους BGO παρείχε τις βέλτιστες τιμές MTF μετά την ανακατασκευή με MLE-OSMAPOSL. Αντίστοιχα, ο ανιχνευτής με κρυστάλλους BGO είχε τα χαμηλότερα επίπεδα θορύβου και τις υψηλότερες τιμές DQE μετά από την εφαρμογή όλων των αλγόριθμων ανακατασκευής. Συμπερασματικά: Η παρούσα μελέτη έδειξε ότι η συνολική απόδοση συστημάτων PET μπορεί να χαρακτηριστεί πλήρως, να βελτιωθεί περαιτέρω και να γίνει πιο απλή με τη διερεύνηση των διαφόρων στοιχείων της αλυσίδας απεικόνισης μέσω μεθόδων Monte Carlo. Η μέθοδος αξιολόγησης ανιχνευτών ΡΕΤ, βασιζόμενη σε επίπεδη πηγή TLC, απαιτεί υλικά που είναι συνηθισμένα στο κλινικό περιβάλλον, μπορεί να εφαρμοστεί πειραματικά και να χρησιμοποιηθεί στην κλινική πράξη. Σε αυτή τη μελέτη χρησιμοποιήθηκε για την εκτίμηση και βελτιστοποίηση της ποιότητας εικόνας, αλλά μπορεί να είναι επίσης χρήσιμη στον τομέα της έρευνας για περαιτέρω ανάπτυξη συστημάτων ΡΕΤ και SPECT, μέσω προσομοιώσεων με το πακέτο λογισμικού GATE. Οι ανακατασκευασμένες εικόνες από το λογισμικό STIR μπορούν επίσης να χρησιμοποιηθούν για την εκτίμηση της κατανομής του ραδιοφαρμάκου, καθώς και την απευθείας λήψη της δοσιμετρικής κατανομής, με αντίστοιχο όφελος στους πυρηνικούς γιατρούς. / The overall purpose of this study was to propose a novel method for the complete image quality characterization and optimization of Positron Emission Tomography (PET) scanners with Monte-Carlo (MC) methods. Α model was developed using the Monte Carlo package of Geant4 Application for Tomographic Emission (GATE) and the software for tomographic image reconstruction (STIR) with cluster computing to obtain reconstructed images. The PET scanner used in this study was the General Electric Discovery-ST (US). The GATE model was validated by comparing results obtained in accordance with the National Electrical Manufacturers Association NEMA-NU-2-2001 protocol (Bettinardi et al 2004, Mawlawi et al 2004). Validation images were reconstructed with the commonly used 2D Filtered Back Projection (FBP2D) and the Kinahan and Rogers FPB3DRP Reprojection Algorithms. Image quality, in terms of the Modulation Transfer Function (MTF), was initially assessed with a novel plane source consisting of a Thin Layer Chromatography (TLC) plate, simulated by a layer of Silica gel on Aluminium foil substrates immersed in Fluorodeoxyglucose (18F-FDG) bath solution (44.4MBq). MTF was assessed from the evaluated STIR digital reconstructed images of the plane source. MTF was also assessed a) in three dimensions, in lines passing through the central axis of the PET scanner, by placing the plane source only horizontally and vertically (5x10cm), b) by scanning 18cm of the transaxial Field Of View (FOV) through the simulation of a horizontal large plane source (18x10cm) and c) by evaluating reconstructed point source images. Furthermore, the study aimed to compare the proposed method with the more traditional technique based on a line source. The complete image quality characterization was assessed in terms of the Detective Quantum Efficiency (DQE) by estimating the MTF and the Normalized Noise Power Spectrum (NNPS) of the 18F-FDG TLC plane source (1 MBq). MTFs curves were estimated from transverse reconstructed images of the plane source, whereas the NNPS data were estimated from the corresponding coronal images. Images were reconstructed by the Maximum Likelihood Estimation (MLE)-OSMAPOSL reprojection algorithm by using various subsets (3 to 21) and iterations (1 to 20). Additionally, the influence of different scintillating crystals on PET scanner’s image quality, in terms of the MTF, the NNPS and the DQE, was also investigated. In this case, OSMAPOSL image reconstruction was assessed by using 15 subsets and 3 iterations. The simulated spatial resolution in terms of Full Width at Half Maximum (FWHM) agreed with published data of Mawlawi et al (2004), within less than 3.29% in 2D and less than 2.51% in 3D with published data of others, respectively. The 2D values for the sensitivity, the scatter fraction and the count-rate were found to agree within less than 0.46%, 4.59% and 7.86%, respectively with corresponding published values. Accordingly, the corresponding 3D values were found to agree to less than 1.62%, 2.85% and 9.13%, respectively with Mawlawi et al (2004) published values. Sensitivity, which was also estimated in the absence of attenuation material by simulating an ideal source, showed differences between the extrapolated and the ideal source values (with and without attenuation) ranging in 2D from 0.04% to 0.82% (radial location R=0cm) in 2D and from 0.52% to 0.67% in 3D mode (radial locations R=10cm). By using this model, sensitivity can be obtained in a more simplified procedure. The simulated noise equivalent count rate was found to be 94.31kcps in 2D and 66.9kcps in 3D at 70 and 15kBq/mL respectively, compared to 94.08kcps in 2D and 70.88kcps in 3D at 54.6kBq/mL and 14kBq/mL respectively, from the published by others values. The simulated image quality was found in excellent agreement with these published values. The MTFs obtained using the FBP2D were in close agreement to those obtained by the FBP3DRP, whereas the MTFs of the OSMAPOSL show, in all cases, that higher frequencies are preserved than in the case of the FBP. FBP reconstructed images obtained from the large horizontal plane source showed that the MTF was found to degrade gradually as we move towards the edge of the FOV. The MTFs of the FBP images along the vertical direction were slightly lower than the corresponding horizontal ones. In addition, the plane source method is less prone to noise than the conventional line source method (sd=0.0031 and 0.0203, respectively). In the case of DQE investigation, MTF values assessed from the evaluated STIR digital reconstructed images, of the TLC based plane source, were found to improve as the number of iterations increased up to 12 and remain almost constant thereafter. Furthermore, variation in the number of subsets didn’t show any effect on the MTF, for equal number of iterations. The noise levels, in terms of the NNPS, in the reconstructed PET image, were found to decrease with the corresponding increase of both the number of iterations and subsets. DQE values were influenced by both MTF and NNPS and were found to increase with the corresponding increase in both number of iterations and subsets. Finally, the PET scanner configuration, incorporating LuAP crystals, provided the optimum MTF values in both 2D and 3DFBP whereas the corresponding configuration with BGO crystals was found with the higher MTF values after OSMAPOSL. The scanner incorporating BGO crystals were also found with the lowest noise levels and the highest DQE values after all image reconstruction algorithms. In conclusion, our study showed that the imaging performance of PET scanners can be fully characterized, further improved and simplified by investigation of the imaging chain components through MC methods. The simulated PET evaluation method, based on a TLC plane source, requires materials commonly found in a clinical environment and can be experimentally implemented and used in clinical practice. In this study it was used for the image quality assessment and optimization, but it can be also useful in research for the further development of PET and SPECT (Single Photon Emission Tomography) scanners though GATE simulations. Reconstructed images by STIR can be also used to obtain radiopharmaceutical distribution of images and direct dose maps, quite useful to nuclear medicine practitioners.
164

Quantitative dynamic 3D PET scanning of the body and brain using LSO tomographs

Walker, Matthew David January 2009 (has links)
No description available.
165

Construction et expérimentation d'un scanner bimodal TEP/TDM combiné de résolution spatiale submillimétrique pour petits animaux

Bergeron, Mélanie January 2015 (has links)
Résumé : La tomographie d’émission par positrons (TEP) permet une imagerie fonctionnelle et moléculaire qui peut bénéficier de l’utilisation conjointe de la tomodensitométrie (TDM), d’abord pour fournir un support anatomique aux images TEP, mais aussi pour permettre une correction plus précise des images TEP. Les appareils existants sont composés de deux scanners juxtaposés nécessitant un déplacement du sujet entre les deux acquisitions, ce qui peut causer des artéfacts de mouvement dans l’image fusionnée TEP/TDM. De plus, le mode de fonctionnement des scanners TDM, basé sur l’intégration du flux de rayons X, délivre une dose de radiations relativement élevée qui peut interférer avec la réalisation d’études/protocoles d’imagerie longitudinales. La réalisation d’un appareil TEP/TDM partageant le même système de détection basé sur le détecteur LabPET II pourrait remédier à ces problèmes. Dans un premier temps, le module de détection LabPET II a été caractérisé pour la TEP et la TDM. Les premières études d’imagerie TDM avec ce détecteur ont aussi été conduites avec un simulateur. Ce travail a permis de déceler un phénomène de diaphonie optique au sein du module de détection. La recherche d’une solution à ce problème a motivé l’évaluation de nouveaux types de réflecteurs métallisés, donc plus opaques, pour en limiter les effets. Le signal relativement faible détecté en TDM a par la suite mené à explorer des scintillateurs alternatifs présentant un rendement lumineux supérieur. L’un de ces scintillateurs permettra d’améliorer sensiblement les performances du scanner LabPET I et pourrait être retenu pour la génération future de scanners LabPET II. || Abstract : Positron emission tomography (PET) provides functional and molecular imaging capabilities that can benefit from joint use with computed tomography (CT), first to provide anatomical support to PET images, but also to allow a more precise correction of PET images. Existing devices are composed of two back-to-back scanners which require displacing the subject between the two acquisitions, possibly causing motion artifacts in the fused PET/CT images. Moreover, the operation mode of CT scanners based on the X-ray signal integration delivers a relatively high radiation dose that can interfere with longitudinal imaging studies/protocols. The realization of a PET/CT scanner sharing the same detection system for both 511 keV and X-ray photons and based on the LabPET II could remedy these problems. As a first step, a characterization of the detection module LabPET II was performed in PET and CT mode. The first CT imaging studies with this detector were also conducted with a simulator. This work allowed identifying an optical crosstalk phenomenon in the detection module. The search for a solution to this problem has motivated the evaluation of new types of metallized, more opaque, reflectors to limit crosstalk effects. The relatively low signal detected in CT led us to explore alternative scintillators having a higher light output. One of these scintillators will significantly improve the performance of the LabPET I scanner and could be used for the next generation of LabPET II scanners.
166

Compensation du mouvement respiratoire dans les images TEP/TDM thoraciques / Respiratory motion compensation in thoracic PET/CT images

Ouksili, Zehor 26 May 2010 (has links)
Cette thèse traite du mouvement respiratoire dans l'imagerie TEP/TDM. L'imagerie TEP est une modalité à exposition longue très influencée par les mouvements involontaires du patient. Ces mouvements produisent des artéfacts dont les conséquences sont sérieuses pour le diagnostic car les tumeurs paraissent plus larges et moins actives. Cette thèse contribue à la résolution de ce problème. En plus de proposer l'architecture d'un système d'acquisition TEP/TDM synchronisée à la respiration, on y développe trois méthodes de traitement de signal et d'images qui peuvent être appliquées pour résoudre différents sous-problèmes: Une méthode originale de segmentation et caractérisation du signal respiratoire pour découvrir les patterns respiratoires "normaux" du patient, une méthode de reconstruction TDM-4D qui permet d'obtenir des images anatomiques du corps à chaque niveau respiratoire désiré et un algorithme itératif amélioré pour reconstruire des images TEP-4D compensées en mouvement respiratoire. Toutes ces méthodes et algorithmes ont été validés et testés sur des données simulées, des données de fantômes, et des données réelles de patients. / This thesis deals with respiratory motion in PET/CT images. It is well known that PET is a modality that requires a long exposure time. During this time, patients moves and breath. These motions produce undesirable artefacts that alter seriously the images and their precision. This has important consequences when diagnosing thoracic, and particularly pulmonary, cancer. Tumours appear larger than they really are and their activity is weaker. This thesis proposes to contribute to solving these problems.We propose the architecture of an integrated PET/CT acquisition system synchronized to respiration. We also develop signal and image processing methods that can be applied to eliminating respiratory artefacts in CT and PET images. The thesis brings three main contributions : An original respiratory signal segmentation and characterization to detect "normal" respiratory patterns, a 4D-CT reconstruction method that creates 3D images of the whole body for any respiratory level and an enhanced iterative algorithm for reconstructing 4D-PET images without respiratory artefacts. The developed methods have validated and tested on simulated, phantom and real patients' data.
167

Optimisation de l’extraction de lumière de scintillation dans les matrices de détecteurs pixellisés pour des applications en tomographie d’émission par positrons (TEP) et en tomodensitométrie (TDM) / Optimization of the extraction of scintillation light in pixelated detector arrays for applications in positron emission tomography (PET) and computed tomography (CT)

Loignon-Houle, Francis January 2016 (has links)
Résumé : Les performances de détecteurs à scintillation, composés d’un cristal scintillateur couplé à un photodétecteur, dépendent de façon critique de l’efficacité de la collecte et de l’extraction des photons de scintillation du cristal vers le capteur. Dans les systèmes d’imagerie hautement pixellisés (e.g. TEP, TDM), les scintillateurs doivent être arrangés en matrices compactes avec des facteurs de forme défavorables pour le transport des photons, au détriment des performances du détecteur. Le but du projet est d’optimiser les performances de ces détecteurs pixels par l'identification des sources de pertes de lumière liées aux caractéristiques spectrales, spatiales et angulaires des photons de scintillation incidents sur les faces des scintillateurs. De telles informations acquises par simulation Monte Carlo permettent une pondération adéquate pour l'évaluation de gains atteignables par des méthodes de structuration du scintillateur visant à une extraction de lumière améliorée vers le photodétecteur. Un plan factoriel a permis d'évaluer la magnitude de paramètres affectant la collecte de lumière, notamment l'absorption des matériaux adhésifs assurant l'intégrité matricielle des cristaux ainsi que la performance optique de réflecteurs, tous deux ayant un impact considérable sur le rendement lumineux. D'ailleurs, un réflecteur abondamment utilisé en raison de ses performances optiques exceptionnelles a été caractérisé dans des conditions davantage réalistes par rapport à une immersion dans l'air, où sa réflectivité est toujours rapportée. Une importante perte de réflectivité lorsqu'il est inséré au sein de matrices de scintillateurs a été mise en évidence par simulations puis confirmée expérimentalement. Ceci explique donc les hauts taux de diaphonie observés en plus d'ouvrir la voie à des méthodes d'assemblage en matrices limitant ou tirant profit, selon les applications, de cette transparence insoupçonnée. / Abstract : The performance of scintillation detectors, made up of a scintillating crystal coupled to a photodetector, critically depends on the collection and extraction efficiency of scintillation photons from the crystal by the sensor. In highly pixelated imaging systems (e.g. PET, CT), scintillators must be arranged in compact arrays with form factors detrimental to light transport, deteriorating the detector performance. The goal of the study was to optimize the pixelated detectors performance by identifying the light loss sources related to the spectral, spatial and angular characteristics of the scintillation photons impinging on scintillators faces. Such information acquired by Monte Carlo simulations enables adequate weighting for the evaluation of achievable gains through structuring of the scintillators for enhanced light extraction to the photodetector. The magnitude of parameters affecting the light collection in arrays, such as adhesive materials absorption and reflector opacity that both have high impact on light output, was evaluated through a factorial design. A frequently used reflector because of its outstanding optical performance was characterized in more realistic conditions compared to air immersion in which its reflectivity is always reported. An important reflectivity quenching of the reflector in optically bonded scintillator arrays was discovered by simulation and confirmed experimentally. This explains the high light crosstalk measured in pixelated arrays as well as paving the way to assembling methods limiting or taking advantage, depending on the application, of this unsuspected transparency.
168

Novel copper-64 complexes for applications in positron emission tomography

Betts, Helen May January 2009 (has links)
No description available.
169

Positron Emission Tomography for Pre-Clinical Sub-Volume Dose Escalation

Bass, Christopher 23 August 2013 (has links)
Purpose: This dissertation focuses on establishment of pre-clinical methods facilitating the use of PET imaging for selective sub-volume dose escalation. Specifically the problems addressed are 1.) The difficulties associated with comparing multiple PET images, 2.) The need for further validation of novel PET tracers before their implementation in dose escalation schema and 3.) The lack of concrete pre-clinical data supporting the use of PET images for guidance of selective sub-volume dose escalations. Methods and materials: In order to compare multiple PET images the confounding effects of mispositioning and anatomical change between imaging sessions needed to be alleviated. To mitigate the effects of these sources of error, deformable image registration was employed. A deformable registration algorithm was selected and the registration error was evaluated via the introduction of external fiducials to the tumor. Once a method for image registration was established, a procedure for validating the use of novel PET tracers with FDG was developed. Nude mice were used to perform in-vivo comparisons of the spatial distributions of two PET tracers, FDG and FLT. The spatial distributions were also compared across two separate tumor lines to determine the effects of tumor morphology on spatial distribution. Finally, the research establishes a method for acquiring pre-clinical data supporting the use of PET for image-guidance in selective dose escalation. Nude mice were imaged using only FDG PET/CT and the resulting images were used to plan PET-guided dose escalations to a 5 mm sub-volume within the tumor that contained the highest PET tracer uptake. These plans were then delivered using the Small Animal Radiation Research Platform (SARRP) and the efficacy of the PET-guided plans was observed. Results and Conclusions: The analysis of deformable registration algorithms revealed that the BRAINSFit B-spline deformable registration algorithm available in SLICER3D was capable of registering small animal PET/CT data sets in less than 5 minutes with an average registration error of .3 mm. The methods used in chapter 3 allowed for the comparison of the spatial distributions of multiple PET tracers imaged at different times. A comparison of FDG and FLT showed that both are positively correlated but that tumor morphology does significantly affect the correlation between the two tracers. An overlap analysis of the high intensity PET regions of FDG and FLT showed that FLT offers additional spatial information to that seen with FDG. In chapter 4 the SARRP allowed for the delivery of planned PET-guided selective dose escalations to a pre-clinical tumor model. This will facilitate future research validating the use of PET for clinical selective dose escalation.
170

Maladie veineuse thromboembolique et cancer : approches diagnostiques / Venous thromboembolism and cancer : diagnostic approaches

Robin, Philippe 11 January 2019 (has links)
La maladie veineuse thrombombolique (MVTE), associant thrombose veineuse profonde et embolie pulmonaire, peut être le premier signe d’un cancer jusque-là méconnu. Des études anciennes ont rapporté que 6 à 15% des patients étaient diagnostiqués d’un cancer occulte dans l’année suivant l’épisode de MVTE. L'identification précoce d’un cancer occulte au moment du diagnostic de la MVTE non provoquée est fondamentale car la présence d’un cancer va conditionner la prise en charge du patient, que ce soit au niveau de la thrombose ou du cancer. Actuellement, les recommandations préconisent un dépistage limité du cancer en cas de MVTE non-provoquée, basé sur un examen clinique complet (interrogatoire, examen physique), un bilan biologique de base, une radiographie thoracique ainsi que tous les examens communément admis pour le dépistage du cancer en fonction de l’âge et du sexe du patient (PSA chez les hommes, mammographie et examen gynécologique chez les femmes). La tomographie par émission de positon (TEP) au 18F-fluorodéoxyglucose (FDG) est une technique d’imagerie en pleine expansion depuis les années 2000. Elle est largement utilisée en routine clinique pour la détection des foyers tumoraux, leur bilan d’extension, l’évaluation des traitements ainsi que le bilan de possibles récidives. En revanche, aucune étude n’a aujourd’hui évalué l’intérêt de cette technique dans le dépistage du cancer chez les patients présentant une MVTE non provoquée. Afin de répondre à cette problématique, l’objectif de cette thèse a été spécifiquement d’étudier l’intérêt de la TEP au FDG pour la détection des néoplasies dans le bilan étiologique d’une MVTE non provoquée au travers des résultats de l'étude MVTEP, étude multicentrique randomisée comprenant une stratégie de dépistage limitée associée à une TEP au FDG à une stratégie limitée seule. / Venous thromboembolism (VTE), which encompasses deep vein thrombosis and pulmonary embolism, can occur as the first manifestation of an underlying occult malignancy. Previous studies reported that the incidence of undiagnosed cancer is 6% to 15% in the year following an unprovoked VTE épisode, i.e. VTE not provoked by a major risk factor.In patients with unprovoked VTE, extensive screening for cancer has been proposed in order to diagnose occult malignancy as early as possible in the hope of improving the prognosis. Current guidelines for occult cancer screening in patients with unprovoked VTE recommend limited cancer screening, including of a thorough medical history and physical examination, basic laboratory investigations, chest X-ray, as well as age-specific and gender-specific cancer screening (colon, breast, and prostate) according to national guidelines.18F-Fluorodesoxyglucose Positron Emission Tomography combined with Computed Tomography (FDG PET/CT) is routinely used for the diagnosis and staging of various malignancies. The use of FDG PET/CT might overcome the limitations of previous extensive screening strategies as it involves whole-body imaging using a single, non-invasive test. To date, there has been no formal assessment of the additional value of FDG PET/CT for occult malignancy screening in patients with unprovoked venous thromboembolism.To address this issue, we conducted a multicenter randomised controlled trial comparing a limited screening strategy to a strategy combining limited screening and FDG PET/CT in patients with unprovoked venous thromboembolism, and then assessed the additional value of FDG PET/CT in addition to a limited strategy.

Page generated in 0.0768 seconds