• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 22
  • 8
  • 6
  • 3
  • 2
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 52
  • 52
  • 52
  • 45
  • 45
  • 15
  • 12
  • 9
  • 8
  • 8
  • 8
  • 8
  • 8
  • 7
  • 7
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Premenstrüel disforik bozukluk tanısı alan kadınlarda bölgesel beyin kan akımı değişikliklerinin Tc-99m HMPAO Beyin Perfüzyon SPECT ile değerlendirilmesi /

Özbek, Feride Meltem. Çerçi, Sevim Süreyya. January 2007 (has links) (PDF)
Tez (Tıpta Uzmanlık) - Süleyman Demirel Üniversitesi, Tıp Fakültesi, Nükleer Tıp Anabilim Dalı, 2007. / Bibliyografya var.
12

Splitting frames based on hypothesis testing for patient motion compensation in SPECT

Ma, Linna. January 2006 (has links)
Thesis (M.S.) -- Worcester Polytechnic Institute. / Keywords: Hypothesis testing; motion compensation; SPECT. Includes bibliographical references (leaves 30-31).
13

Noninvasive longitudinal quantification of β-cell mass with [111In]-labeled exendin-4 / 111In標識exendin-4を用いた、非侵襲的かつ縦断的なベータ細胞量の定量

Fujita, Naotaka 23 January 2020 (has links)
京都大学 / 0048 / 新制・課程博士 / 博士(医学) / 甲第22149号 / 医博第4540号 / 新制||医||1039(附属図書館) / 京都大学大学院医学研究科医学専攻 / (主査)教授 川口 義弥, 教授 上本 伸二, 教授 富樫 かおり / 学位規則第4条第1項該当 / Doctor of Medical Science / Kyoto University / DFAM
14

Visualizing prolonged hyperperfusion in post-stroke epilepsy using postictal subtraction SPECT / 発作後subtraction SPECTを用いた脳卒中後てんかんにおける遷延性過灌流の可視化

Fukuma, Kazuki 23 March 2021 (has links)
京都大学 / 新制・論文博士 / 博士(医学) / 乙第13397号 / 論医博第2221号 / 新制||医||1051(附属図書館) / (主査)教授 伊佐 正, 教授 中本 裕士, 教授 渡邉 大 / 学位規則第4条第2項該当 / Doctor of Medical Science / Kyoto University / DFAM
15

Resting-state functional MR imaging identifies cerebrovascular reactivity impairment in patients with arterial occlusive diseases: A pilot study / 安静時機能的磁気共鳴画像は動脈閉塞性疾患患者における脳血管反応性の障害を同定する

Nishida, Sei 25 March 2019 (has links)
京都大学 / 0048 / 新制・課程博士 / 博士(医学) / 甲第21671号 / 医博第4477号 / 新制||医||1035(附属図書館) / 京都大学大学院医学研究科医学専攻 / (主査)教授 髙橋 良輔, 教授 溝脇 尚志, 教授 黒田 知宏 / 学位規則第4条第1項該当 / Doctor of Medical Science / Kyoto University / DFAM
16

The effect of reconstruction algorithms (iterative versus filtered backprojection) on the diagnosis of single pulmonary nodules using Thallium-201 and Technetium-99m MIBI SPECT

Ambayi, Rudo 04 1900 (has links)
Thesis (MScMed)--Stellenbosch University, 2004. / Copy not signed by author. / ENGLISH ABSTRACT: This study involved 33 patients, 19 men and 14 women. The age range was wide (20-90 years) and median age was 57 years. These patients had a single pulmonary nodule (SPN) defined radiologically as a well defined, round or oval intrapulmonary lung lesion not associated with atelectasis or adenopathy on chest radiography or computed tomography. Patients were investigated with Tc-99m MIBI and TI-201 (25 patients) and with Tc-99m MIBI alone (8 patients). Single photon emission computed tomography images were reconstructed using both iterative reconstruction (Ordered Subsets - Expectation Maximisation: aSEM) and filtered backprojection (FBP), on the Hermes system. Transverse, coronal and sagittal slices were displayed on the screen using a grey scale. The aSEM and FBP images for each study were co-registered semi-automatically using the multimodality programme on the Hermes. The best slice for the lesion was chosen according to the best view used to locate the SPN on chest radiograph. Regions of interest (Ral) were drawn manually outside the outer margin of the detected lesion, first on the aSEM image. This was automatically mirrored on the co-registered FBP image. For most patients, the background was automatically mirrored horizontally on the contralateral side, again, first on the OSEM then automatically on the FBP image. Automatic vertical mirroring or manual horizontal mirroring was used when background was found to be in a visually 'hot' area like the heart or vertebrae. The average counts and standard deviation of the Ral and background were generated automatically. Semi-quantitative image analysis was done by calculating the signal-to-noise ratio (SNR) and tumour-to-background (TIB) ratio using the following formulae: SNR = Mean counts ROI(lesion) - Mean counts background Standard deviation background TIB rati.o = -M---e-a-n-'--c-o--u-n-'t-s- ROI(lesion) Mean counts background Detection was found to be the same for the two reconstruction algorithms, that is, every lesion detected by using OSEM could also be detected by using FBP. However lesion detection did differ between Tl-201 and Tc-99m-MIBI. Sensitivity and specificity were calculated for different thresholds of SNR and TIB ratios. Receiver operating characteristics (ROC) curves were drawn to represent the different sensitivities and specificities at each threshold. Tuberculosis (TB) was not included in this analysis as uptake of Tl-20l was found to be significantly high and comparable to that of malignant nodules. However the effect of OSEM and FBP on the 'positive' TB nodules was assessed separately. By calculating the area under the ROC curves, TI-201 using OSEM was shown to be more accurate at differentiating malignant nodules from benign ones than FBP. Although this difference was not statistically significant (p=0.1 0), there was a clear tendency. The two reconstruction algorithms were found to be almost equally accurate, when using Tc-99m-MIBI, the difference between them being considerably insignificant. In conclusion, it was shown that there is a tendency that OSEM outperforms FBP for studies using Tl-201 but not for Tc-99m-MIBI. / AFRIKAANSE OPSOMMING: Hierdie studie sluit 33 pasiënte in, 19 mans en 14 vroue. Die ouderdomme wissel tussen 20 en 90 jaar met 'n gemiddelde ouderdom van 57 jaar. Elkeen van die pasiënte het 'n enkel longnodule (SPN) op borskas X-straal en/of rekenaar tomografie getoon, wat radiologies gedefinieer word as 'n goed omskrewe, ronde of ovaal intrapulmonale longletsel wat nie met atelektase of adenopatie geassosieer is nie. Pasiënte is met Tc-99m MIDI en TI-201 (25 pasiënte) of slegs met Tc-99m MIBI (8 pasiënte) ondersoek. Enkelfoton emissie rekenaar tomografiese (EFERT) beelde is met beide iteratiewe rekonstruksie (Ordered Subsets - Expectation Maximisation: OSEM) en gefilterde terugprojeksie (FBP) met die Hermes sisteem gerekonstrueer. Transvers, koronale en sagittale snitte is in grysskaal op die sisteem vertoon. Die OSEM en FBP beelde vir elke studie is semi-outomaties gekoregistreer met behulp van die multimodaliteitsprogram op die Hermes. Die optimale snit vir elke letsel is gekies volgens die beste aansig op die borskas X-straalom die SPN te lokaliseer. Gebiede van belang (ROl) is met die hand buite-om die buitenste rand van die letsel getrek op die OSEM beeld en daarna outomaties in die ooreenstemmende area op die gekoregistreerde FPB beeld geplaas. Vir die meeste pasiënte is die agtergrond outomaties as horisontale spieëlbeeld op die kontralaterale kant geplaas, eers op die OSEM en dan outomaties op die FBP beeld. 'n Outomatiese vertikale spieëlbeeld of manuele horisontale verskuiwing van die agtergrondsarea is gedoen indien die agtergrond oorvleuel het met 'n 'warm' area soos die hart of werwels. Die gemiddelde tellings en standaardafwyking van die ROl en agtergrond is outomaties gegenereer. Semi-kwantitatiewe beeldanalise is gedoen deur berekening van die sein-tot-agtergrond verhouding (signal-to-noise ratio - SNR) en tumor-tot-agtergrond (TIB) verhouding met behulp van die volgende formules: SNR = gemiddelde tellings ROI(letsel) - gemiddelde tellings agtergrond Standaard afwyking van agtergrond TIB rati.o = -g=em--id-d-e-l-d-e--te=ll-in-g-s__R:_O-I(-le-t-s'e-l) gemiddelde tellings agtergrond Opsporing is soortgelyk bevind vir die twee rekonstruksie algoritmes, dit wil sê elke letselopgespoor met behulp van OSEM kon ook met FBP opgespoor word. Letselwaameming het egter verskil tussen TI-201 en Tc-99m-MIBI. Sensitiwiteit en spesifisiteit is vir verskillende drempels van SNR en TIB verhoudings bereken. 'Receiver operating characteristics' (ROC) kurwes is getrek om die verskillende sensitiwiteite en spesifisiteite by elke drempel te verteenwoordig. Tuberkulose (TB) is nie in hierdie analise ingesluit nie aangesien opname van Tl-201 beduidend hoog en vergelykbaar met die van maligne nodules was. Die effek van OSEM en FBP op die 'positiewe' TB nodules is egter apart beoordeel. Deur berekening van die area onder die ROC kurwes, is getoon dat OSEM van Tl-201 tomografiese data meer akkuraat as FBP was om maligne van benigne nodules te onderskei. Alhoewel hierdie verskil nie statisties betekenisvol was nie (p=0.10), is daar wel 'n duidelike neiging gevind. Die twee rekonstruksie algoritmes was byna ewe akkuraat wanneer Tc-99m-MIBI gebruik is, met duidelik geen betekenisvolle verskil tussen die algoritmes nie. Gevo lgtrekking In hierdie studie is dit getoon dat daar 'n neiging is dat OSEM beter vaar as FBP vir studies met tallium-201 maar nie vir Tc-99m-MIBI nie.
17

Diabetes in 3D : β-cell mass assessments in disease models & evaluation of SPECT based imaging

Parween, Saba January 1900 (has links)
Diabetes is a rapidly growing disease with 415 million affected adults worldwide. The pancreatic endocrine cells, most importantly the insulin producing β-cells, play an important role in regulating blood glucose homeostasis. Type 1 diabetes (T1D) is characterized by the inability of the pancreas to secrete sufficient amounts of insulin due to autoimmune destruction of insulin producing β-cells. Type 2 diabetes (T2D) on the other hand is characterized by defects in insulin secretion and insulin sensitivity. Alterations in the β-cell mass (BCM) and/or function play a major role in the development and progression of the disease. Understanding BCM dynamics in disease models is therefore a key aspect for better interpretation of research results. In this thesis, we have used optical projection tomography (OPT) as a tool to evaluate a non-invasive imaging modality for β-cell scoring and to study disease dynamics in frequently used animal models for T1D and T2D. The possibility to monitor BCM in vivo would radically improve our competence in studying the pathogenesis of diabetes and in therapeutic interventions. Single photon emission computed tomography (SPECT) is a widely used technique that has become a promising approach to monitor changes in BCM in vivo. A key issue for using this approach is to evaluate the β-cell specificity and read out of the utilized radiotracers. This is most commonly performed by conventional stereological approaches, which rely on the extrapolation of 2D data. We developed a protocol for SPECT-OPT multimodal imaging that enables rapid and accurate cross evaluation of SPECT based assessments of BCM. While histological determination of islet spatial distribution was challenging, SPECT and OPT revealed similar distribution patterns of the radiotracer 111In-exendin-3 and insulin positive β-cell volumes respectively between different pancreatic lobes, both visually and quantitatively. We propose SPECT-OPT multimodal imaging as an accurate and better approach for validating the performance of β-cell radiotracers. The leptin deficient ob/ob mouse is a widely used model for studies of metabolic disturbances leading to T2D, including obesity and insulin resistance. By OPT imaging we created the first 3D-spatial and quantitative account of BCM distribution in this model. We observed a previously unreported degree of cystic lesions in hypertrophic islets, that were occupied by red blood cells (RBCs) and/or fibrin mesh. We propose that these lesions are formed by a mechanism involving the extravasation of RBCs/plasma due to increased blood flow and islet vessel instability. Further, our data indicate that the primary lobular compartments of the ob/ob pancreas have different potentials for expanding their β-cell population. Unawareness of these characteristics of β-cell expansion in ob/ob mice presented in this study may significantly influence ex vivo and in vivo assessments of this model in studies of β-cell adaptation and function. The tomographic data, on which this study was based, will be made publically available as a resource to the research community for the planning and interpretation of research involving this model. There are limited studies on early metabolic and functional changes of BCM in the settings of T1D. In order to assess initial metabolic alterations in BCM before the onset of diabetes, we characterized congenic diabetes prone Bio-breeding (BB) DR.lyp/lyp rats, a widely used model for T1D diabetes. We observed lower acute insulin response, reduced islet blood flow and a significant reduction in the BCM of small and medium sized islets at a very early stage (40 days), i.e. before insulitis and development of diabetes. Underlying changes in islet function may be a previously unrecognized factor of importance in the development of T1D.
18

Mapeamento topográfico metabólico de carcinomas espinocelulares de cabeça e pescoço utilizando a fusão de imagens 18 F-FDG PET - TC. / Topographic metabolic map of head and neck squamous cell carcinoma using image fusion between 18 F-FDG PET - TC.

Santos, Denise Takehana dos 22 March 2005 (has links)
O objetivo desta pesquisa foi estabelecer uma metodologia para avaliar carcinomas espinocelulares (CEC) de cabeça e pescoço, identificando e distinguindo áreas de maior atividade metabólica dentro da neoplasia, associando dados simultaneamente adquiridos, obtidos por diferentes modalidades de aquisição de imagens, combinando informações metabólicas e anatômicas num único exame. A população estudada consistiu de 17 pacientes com carcinoma espinocelular (CEC) de cabeça e pescoço pertencentes aos arquivos do Departamento de Imagem do Hospital do Câncer, São Paulo. As imagens de TC (tomografia computadorizada) e do 18 F-FDG-PET (tomografia por emissão de pósitrons) foram simultaneamente adquiridas utilizando um aparelho não dedicado. Os dados originais foram transferidos para uma estação de trabalho independente com programa de computação gráfica para o processamento dos grupos individuais e fusão em um único grupo, contendo os dados fisiológicos e metabólicos. Os achados foram definidos como positivos na presença de focos com aumento da concentração do radiofármaco em áreas não relacionadas à distribuição normal do mesmo. Em 77% dos casos (n=13), a hipercaptação foi detectada ao centro da lesão e em 23% (n=4) dos casos houve comportamento diferente, com hipercaptação excêntrica. A fusão de imagens simultaneamente adquiridas num único exame ( 18 F- FDG PET e TC) possibilitou o mapeamento topográfico metabólico das lesões estudadas e foi possível localizar áreas de maior atividade metabólica dentro do próprio 13 tumor, verificando recidivas ou metástases, possibilitando aumentar as opções quanto ao planejamento radioterápico ou cirúrgico a serem seguidos. / The aim of this study is to propose a methodological approach to evaluate head and neck squamous cell carcinoma (SCCA) in order to identify and to distinguish areas of higher metabolic activity inside the lesion combining the functional metabolic and morphological data simultaneously acquired in a non dedicated PET-CT device. The study population consisted of 17 patients, with SCCA of the head and neck carcinoma. These patients were submitted to a non-dedicated 18 F- FDG- PET imaging using a system with low dose CT and Positron emission coincidence acquisition capabilities. The image acquisition was then transferred to an ENTEGRA 2 NT workstation to generate groups of individual images (metabolic and anatomical data) and image fusion (CT + PET). In those patients with anomalous concentrations of 18 F-FDG, the lesion was depicted on three planes (axial, coronal and sagittal) in CT, PET, and the image fusion at the computer screen. The findings were defined as positive in the presence of well-defined focal area of increased uptake in regions unrelated to the normal biodistribution of the tracer on visual inspection. Two examiners interpreted the images in different sessions, in order to get an agreement. Subsequently, the sites of higher metabolic activity inside the tumor were identified and classified in centric or eccentric, according to their relative location. Observing the images, we found 77.00% of the patients with the site of higher activity at the center of lesion. In 23.00% of the patients a different 15 behavior, with the tracer increased eccentrically to the lesion. This technique gave a realistic view of the functional metabolism, locating the anatomical tumor area and helping in future treatment planning.
19

Eficácia da estimulação magnética transcraniana em pacientes com zumbido e audiometria normal: avaliação clínica e por neuroimagem / Transcranial magnetic stimulation efficiency in patients with tinnitus and normal pure-tone audiometry: clinical and neuroimaging evaluation.

Renata de Almeida Marcondes 11 March 2009 (has links)
INTRODUÇÃO: O zumbido é um sintoma muito freqüente e de difícil tratamento. Atualmente, algumas evidências mostraram que o zumbido está associado a alterações funcionais do sistema nervoso central. Nos últimos anos, a modulação da atividade cortical relacionada ao zumbido por meio da estimulação magnética transcraniana repetitiva (EMT) tem sido proposta como um tratamento promissor. Entretanto, nenhum estudo avaliou sua eficácia no controle do zumbido em pacientes sem perda auditiva concomitante, nem seu efeito de longa duração. O objetivo do trabalho foi investigar os efeitos imediatos e a longo prazo da estimulação magnética transcraniana repetitiva de baixa freqüência (1 Hz) em pacientes com zumbido e audiometria normal. MÉTODOS: Utilizando um ensaio clínico aleatorizado, duplo cego e paralelo, foram randomizados 20 pacientes para receber a EMT ativa ou placebo. A estimulação foi aplicada no córtex têmporo-parietal esquerdo por cinco dias consecutivos. A avaliação clínica foi feita por meio do Tinnitus Handicap Inventory e da escala análogo-visual. A avaliação por neuroimagem foi feita por meio do SPECT, o qual foi realizado antes e 14 dias após o período de estimulação. RESULTADOS: Clinicamente, o grupo submetido à estimulação magnética transcraniana ativa apresentou uma melhora significativa do zumbido, mantida por até seis meses, quando comparado ao grupo que recebeu a estimulação placebo. A avaliação por SPECT demonstrou redução do fluxo sanguíneo no lobo temporal esquerdo após o período de estimulação ativa. CONCLUSÃO: Os resultados revelam o potencial terapêutico da estimulação magnética transcraniana como nova ferramenta no tratamento do zumbido, proporcionando redução significativa do incômodo provocado pelo zumbido por até seis meses e reduzindo a atividade neuronal no córtex temporal. / INTRODUCTION: Tinnitus is a frequent disorder which is very difficult to treat. There is compelling evidence that tinnitus is associated with functional alterations in the central nervous system. Recently, the targeted modulation of tinnitus-related cortical activity through repetitive transcranial magnetic stimulation (rTMS) has been proposed as a promising new treatment approach. However, its efficacy in patients without hearing loss has never been studied, as well as the long-term duration of its effect. The objective of this study was to investigate both immediate and long-term effect of low frequency (1 Hz) rTMS in patients with tinnitus and normal hearing. METHODS: Using a randomized double-blind and parallel clinical trial, 20 patients were divided to receive either active or placebo transcranial magnetic stimulation over the left temporoparietal cortex for 5 consecutive days. The clinical evaluation was performed by using the Tinnitus Handicap Inventory and the visual analogue scale. The neuroimage evaluation included and ECD-SPECT imaging, which was performed before and 14 days after rTMS. RESULTS: From the clinical point of view, the group submitted to active rTMS presented significant improvement of the tinnitus score, which was sustained up to six months, when compared to the group that received the sham rTMS. SPECT measurements demonstrated a reduction of metabolic activity in the left temporal lobe after active rTMS. CONCLUSION: These results support the potential of rTMS as a new therapeutic tool for the treatment of chronic tinnitus, by demonstrating a significant reduction of tinnitus complaints over a period of at least six months and a significant reduction of neural activity in the temporal cortex.
20

Myokardskintigrafi fynd vs koronarangiografi fynd vid kranskärlsjukdom detektering på Universitetssjukhuset Örebro.

Ibrahim, Hanna January 2019 (has links)
Bakgrund: Kranskärlssjukdom (CAD) är en hjärtsjukdom som kan diagnostiseras med icke-invasiva metoder, såsom myocardial perfusion imaging med single-photon emission computed tomography (SPECT), och genom invasiva metoder, såsom invasiv koronarangiografi (ICA). ICA är den golden standardmetod för att diagnostisera CAD. Men å andra sidan är ICA mer kostsam än SPECT och kan orsaka många komplikationer. Metoder och resultat: det är en retrospektiv kohortstudie. Studien analyserade 62 patienter som har genomgått både SPECT och ICA under 2018 vid Universitetssjukhuset Örebro (USÖ). Av dessa 62 utförde 56 patienter SPECT först. Analyseringen gjordes för att undersöka hur väl resultatet av ICA-sjukdomsdetektering och lokalisering kunde bestämmas av SPECT. Aktiv CAD definierades som närvaron av en behandling-krävande signifikant stenos vid ICA. SPECT-resultaten visade att 91% av fallen var patologiska och 9% var icke-patologiska. Sensitivitet, specificitet och noggrannhet för SPECT för detektering av aktiv CAD var 89%, 7% respektive 47% vid referens till ICA. Medan positiva prediktiva värden (PV +) och negativa prediktiva värden (PV-) var 48% respektive 40%. SPECT sensitivitet för lokalisering av defekter i referens till ICA var 35% för LAD-defekter, 68% för LCX-defekter och 92% för RCA-defekter. Slutsats: Resultatet skilde sig från den ursprungliga hypotesen. SPECT anses fortfarande vara effektiv för att identifiera patienter med aktiv CAD. Därför kan SPECT användas som initial undersökningsmetod för utvärdering av CAD hos patienter med låg till måttlig risk. SPECT var inte optimalt för att lokalisera defekterna.

Page generated in 0.2281 seconds