Spelling suggestions: "subject:"microcomputed tomography"" "subject:"mircocomputed tomography""
21 |
Eficácia da estimulação magnética transcraniana em pacientes com zumbido e audiometria normal: avaliação clínica e por neuroimagem / Transcranial magnetic stimulation efficiency in patients with tinnitus and normal pure-tone audiometry: clinical and neuroimaging evaluation.Marcondes, Renata de Almeida 11 March 2009 (has links)
INTRODUÇÃO: O zumbido é um sintoma muito freqüente e de difícil tratamento. Atualmente, algumas evidências mostraram que o zumbido está associado a alterações funcionais do sistema nervoso central. Nos últimos anos, a modulação da atividade cortical relacionada ao zumbido por meio da estimulação magnética transcraniana repetitiva (EMT) tem sido proposta como um tratamento promissor. Entretanto, nenhum estudo avaliou sua eficácia no controle do zumbido em pacientes sem perda auditiva concomitante, nem seu efeito de longa duração. O objetivo do trabalho foi investigar os efeitos imediatos e a longo prazo da estimulação magnética transcraniana repetitiva de baixa freqüência (1 Hz) em pacientes com zumbido e audiometria normal. MÉTODOS: Utilizando um ensaio clínico aleatorizado, duplo cego e paralelo, foram randomizados 20 pacientes para receber a EMT ativa ou placebo. A estimulação foi aplicada no córtex têmporo-parietal esquerdo por cinco dias consecutivos. A avaliação clínica foi feita por meio do Tinnitus Handicap Inventory e da escala análogo-visual. A avaliação por neuroimagem foi feita por meio do SPECT, o qual foi realizado antes e 14 dias após o período de estimulação. RESULTADOS: Clinicamente, o grupo submetido à estimulação magnética transcraniana ativa apresentou uma melhora significativa do zumbido, mantida por até seis meses, quando comparado ao grupo que recebeu a estimulação placebo. A avaliação por SPECT demonstrou redução do fluxo sanguíneo no lobo temporal esquerdo após o período de estimulação ativa. CONCLUSÃO: Os resultados revelam o potencial terapêutico da estimulação magnética transcraniana como nova ferramenta no tratamento do zumbido, proporcionando redução significativa do incômodo provocado pelo zumbido por até seis meses e reduzindo a atividade neuronal no córtex temporal. / INTRODUCTION: Tinnitus is a frequent disorder which is very difficult to treat. There is compelling evidence that tinnitus is associated with functional alterations in the central nervous system. Recently, the targeted modulation of tinnitus-related cortical activity through repetitive transcranial magnetic stimulation (rTMS) has been proposed as a promising new treatment approach. However, its efficacy in patients without hearing loss has never been studied, as well as the long-term duration of its effect. The objective of this study was to investigate both immediate and long-term effect of low frequency (1 Hz) rTMS in patients with tinnitus and normal hearing. METHODS: Using a randomized double-blind and parallel clinical trial, 20 patients were divided to receive either active or placebo transcranial magnetic stimulation over the left temporoparietal cortex for 5 consecutive days. The clinical evaluation was performed by using the Tinnitus Handicap Inventory and the visual analogue scale. The neuroimage evaluation included and ECD-SPECT imaging, which was performed before and 14 days after rTMS. RESULTS: From the clinical point of view, the group submitted to active rTMS presented significant improvement of the tinnitus score, which was sustained up to six months, when compared to the group that received the sham rTMS. SPECT measurements demonstrated a reduction of metabolic activity in the left temporal lobe after active rTMS. CONCLUSION: These results support the potential of rTMS as a new therapeutic tool for the treatment of chronic tinnitus, by demonstrating a significant reduction of tinnitus complaints over a period of at least six months and a significant reduction of neural activity in the temporal cortex.
|
22 |
Retrieving Information from Scattered Photons in Medical ImagingJha, Abhinav K. January 2013 (has links)
In many medical imaging modalities, as photons travel from the emission source to the detector, they are scattered by the biological tissue. Often this scatter is viewed as a phenomenon that degrades image quality, and most research is focused on designing methods for either discarding the scattered photons or correcting for scatter. However, the scattered photons also carry information about the tissue that they pass through, which can perhaps be extracted. In this research, we investigate methods to retrieve information from the scattered photons in two specific medical imaging modalities: diffuse optical tomography (DOT) and single photon emission computed tomography (SPECT). To model the scattering of photons in biological tissue, we investigate using the Neumann-series form of the radiative transport equation (RTE). Since the scattering phenomenon are different in DOT and SPECT, the models are individually designed for each modality. In the DOT study, we use the developed photon-propagation model to investigate signal detectability in tissue. To study this detectability, we demonstrate the application of a surrogate figure of merit, based on Fisher information, which approximates the Bayesian ideal observer performance. In the SPECT study, our aim is to determine if only the SPECT emission data acquired in list-mode (LM) format, including the scattered-photon data, can be used to compute the tissue-attenuation map. We first propose a path-based formalism to process scattered photon data, and follow it with deriving expressions for the Fisher information that help determine the information content of LM data. We then derive a maximum-likelihood expectation-maximization algorithm that can jointly reconstruct the activity and attenuation map using LM SPECT emission data. While the DOT study can provide a boost in transition of DOT to clinical imaging, the SPECT study will provide insights on whether it is worth exposing the patient to extra X-ray radiation dose in order to obtain an attenuation map. Finally, although the RTE can be used to model light propagation in tissues, it is computationally intensive and therefore time consuming. To increase the speed of computation in the DOT study, we develop software to implement the RTE on parallel computing architectures, specifically the NVIDIA graphics processing units (GPUs).
|
23 |
Mapeamento topográfico metabólico de carcinomas espinocelulares de cabeça e pescoço utilizando a fusão de imagens 18 F-FDG PET - TC. / Topographic metabolic map of head and neck squamous cell carcinoma using image fusion between 18 F-FDG PET - TC.Denise Takehana dos Santos 22 March 2005 (has links)
O objetivo desta pesquisa foi estabelecer uma metodologia para avaliar carcinomas espinocelulares (CEC) de cabeça e pescoço, identificando e distinguindo áreas de maior atividade metabólica dentro da neoplasia, associando dados simultaneamente adquiridos, obtidos por diferentes modalidades de aquisição de imagens, combinando informações metabólicas e anatômicas num único exame. A população estudada consistiu de 17 pacientes com carcinoma espinocelular (CEC) de cabeça e pescoço pertencentes aos arquivos do Departamento de Imagem do Hospital do Câncer, São Paulo. As imagens de TC (tomografia computadorizada) e do 18 F-FDG-PET (tomografia por emissão de pósitrons) foram simultaneamente adquiridas utilizando um aparelho não dedicado. Os dados originais foram transferidos para uma estação de trabalho independente com programa de computação gráfica para o processamento dos grupos individuais e fusão em um único grupo, contendo os dados fisiológicos e metabólicos. Os achados foram definidos como positivos na presença de focos com aumento da concentração do radiofármaco em áreas não relacionadas à distribuição normal do mesmo. Em 77% dos casos (n=13), a hipercaptação foi detectada ao centro da lesão e em 23% (n=4) dos casos houve comportamento diferente, com hipercaptação excêntrica. A fusão de imagens simultaneamente adquiridas num único exame ( 18 F- FDG PET e TC) possibilitou o mapeamento topográfico metabólico das lesões estudadas e foi possível localizar áreas de maior atividade metabólica dentro do próprio 13 tumor, verificando recidivas ou metástases, possibilitando aumentar as opções quanto ao planejamento radioterápico ou cirúrgico a serem seguidos. / The aim of this study is to propose a methodological approach to evaluate head and neck squamous cell carcinoma (SCCA) in order to identify and to distinguish areas of higher metabolic activity inside the lesion combining the functional metabolic and morphological data simultaneously acquired in a non dedicated PET-CT device. The study population consisted of 17 patients, with SCCA of the head and neck carcinoma. These patients were submitted to a non-dedicated 18 F- FDG- PET imaging using a system with low dose CT and Positron emission coincidence acquisition capabilities. The image acquisition was then transferred to an ENTEGRA 2 NT workstation to generate groups of individual images (metabolic and anatomical data) and image fusion (CT + PET). In those patients with anomalous concentrations of 18 F-FDG, the lesion was depicted on three planes (axial, coronal and sagittal) in CT, PET, and the image fusion at the computer screen. The findings were defined as positive in the presence of well-defined focal area of increased uptake in regions unrelated to the normal biodistribution of the tracer on visual inspection. Two examiners interpreted the images in different sessions, in order to get an agreement. Subsequently, the sites of higher metabolic activity inside the tumor were identified and classified in centric or eccentric, according to their relative location. Observing the images, we found 77.00% of the patients with the site of higher activity at the center of lesion. In 23.00% of the patients a different 15 behavior, with the tracer increased eccentrically to the lesion. This technique gave a realistic view of the functional metabolism, locating the anatomical tumor area and helping in future treatment planning.
|
24 |
Dopamine transporter in alcoholism:a SPET studyLaine, P. (Pekka) 16 October 2001 (has links)
Abstract
A large body of animal studies indicates that reinforcement from alcohol is
associated with dopaminergic neurotransmission in the mesocorticolimbic pathway.
However, as most psychiatric phenomena cannot be studied with animals, human
studies are needed. Furthermore, because of the fluctuating nature of phenomena
regarding the status of abuse and withdrawal, repeated observations of the same
study subjects under different situations can elucidate a variety of
pathophysiological mechanisms.
In this study 42 alcoholics were monitored during withdrawal and 30
alcoholics after four weeks of abstinence.
123I-β-CIT
SPET was used as a method for the semi quantification of their striatal dopamine
transporter (DAT) densities reflecting the function and structure of the
dopaminergic system.
DAT density was markedly lower during withdrawal among alcoholics as
compared to control subjects, but it elevated during abstinence to the level of
healthy volunteers. This increases in DAT density during withdrawal and
afterwards correlated with the depression scores of alcoholics. DAT density
correlated with the Novelty Seeking (NS) personality trait, especially among
abstinent alcoholics. After four weeks of controlled abstinence alcoholics with
an A1 allele of dopamine receptor D2 were found to have higher DAT densities than
alcoholics without it.
The results indicate that striatal DAT density is associated with mood,
personality, A1 genotype and the length of the abstinence period after heavy
alcohol drinking.
|
25 |
A Bayesian Approach To Positron Emission TomographyMondal, Partha Pratim 12 1900 (has links) (PDF)
No description available.
|
26 |
前立腺がんの核医学画像診断を目的とした放射性分子イメージングプローブの開発に関する研究原田, 直弥 24 March 2014 (has links)
京都大学 / 0048 / 新制・課程博士 / 博士(薬学) / 甲第18218号 / 薬博第808号 / 新制||薬||238(附属図書館) / 31076 / 京都大学大学院薬学研究科医療薬科学専攻 / (主査)教授 佐治 英郎, 教授 橋田 充, 教授 髙倉 喜信 / 学位規則第4条第1項該当 / Doctor of Pharmaceutical Sciences / Kyoto University / DFAM
|
27 |
Imaging of renal hyperparathyroidism using SPECT/CT with low-dose localizing CTDoruyter, Alexander Govert George 12 1900 (has links)
Thesis (MMed)--Stellenbosch University, 2013. / ENGLISH ABSTRACT: Background: Hybrid imaging using single photon emission computed tomography/low dose (x-ray) computed tomography (SPECT/LDCT) is of benefit in preoperative scintigraphy of primary hyperparathyroidism. The role of SPECT/LDCT in preoperative assessment of renal hyperparathyroidism has not yet been examined. The aim of the study was to determine whether SPECT/LDCT conferred any benefit over SPECT alone in terms of detection and/or localization of hyperfunctioning parathyroid tissue in this patient group.
Methods: A retrospective study of patients with renal hyperparathyroidism and positive planar and SPECT scintigraphy was undertaken. All patients underwent planar scintigraphy using 99mTc-pertechnetate immediately followed by 99mTc-sestamibi as well as SPECT/LDCT 60 min after sestamibi injection and a delayed static image to assess for differential washout at 2-3 hours. Planar subtraction images were generated. For each patient, two nuclear physicians reported on planar+ SPECT images followed by planar + SPECT/LDCT images (assisted by a radiologist). Confidence for the presence of hyperfunctioning parathyroid tissue as well as confidence of location was scored on a Likert-type scale. Interpretation of planar + SPECT was compared with interpretation of planar + SPECT/LDCT. The impact of LDCT on equivocal lesions and number of ectopic lesions detected was also assessed. Results: Twenty patients (M:13; F:7) imaged between February 2008 and June 2011 were included [mean age: 40 years (24 – 55)]. Mean creatinine was 687 μmol/l (169-1213), mean corrected calcium: 2.55 mmol/l (1.95-3.33) and median PTH 167 pmol/l (2.4 - >201). Thirty-five lesions were detected on planar and SPECT and this was unchanged after assessment of the LDCT data. Confidence for the presence of parathyroid pathology changed in 5 patients (5 lesions) with the addition of LDCT. LDCT changed the mean confidence of parathyroid pathology from 3.17 to 3.29 (p=0.16). Addition of LDCT reduced the number of equivocal lesions from 18 (14 patients) to 14 (10 patients) (p=0.13). The addition of LDCT changed localization in 4 lesions (3 patients). Confidence in localization of pathology changed in 9 lesions (7 patients) and the mean localization confidence score was improved from 4.2 to 4.46 (p=0.002) with LDCT. The number of lesions classified as ectopic increased from 5 (on planar+SPECT) to 8 (with addition of LDCT) (p=0.25).
Conclusion: In renal hyperparathyroidism SPECT/LDCT altered localization of lesions detected on planar and SPECT alone and improved reader confidence of localization accuracy. SPECT/LDCT conferred no additional benefit over SPECT in terms of detection, confidence of parathyroid pathology or ability to distinguish equivocal from non-equivocal parathyroid lesions. The addition of LDCT did not detect significantly more ectopic lesions. Whereas the minor improvement in reader confidence of localization (with addition of LDCT) was of questionable clinical significance, we speculate that the changed and presumably improved localization of lesions on SPECT/LDCT had potential clinical impact in a significant proportion of patients. On this basis we recommend the use of hybrid SPECT/LDCT in imaging of renal hyperparathyroidism when surgery is considered. / AFRIKAANSE OPSOMMING: Agtergrond: Hibriedbeelding met enkelfoton emissie rekenaartomografie / lae dosis rekenaartomografie (EFERT/LDRT) is voordelig in pre-operatiewe beelding van primêre hiperparatiroïedisme. Die rol van EFERT/RT in pre-operatiewe evaluering van renale hiperparatiroïedisme is nog nie ondersoek nie. Die doel van hierdie studie was om in hierdie pasiëntgroep te bepaal of EFERT/RT 'n voordeel bo EFERT alleen verleen.
Metode: 'n Retrospektiewe studie van pasiënte met renale hiperparatiroïedisme en positiewe planare en EFERT flikkergrafie is onderneem. Na die toediening van 99mTc-pertegnetaat is planare beelding op alle pasiënte gedoen, onmiddellik gevolg deur 99mTc-sestamibi sowel as EFERT/RT beelding 60 min na sestamibi inspuiting en 'n laat statiese beeld vir differensiële uitwas op 2-3 uur. Planare subtraksiebeelde is verkry. Twee kerngeneeskundiges het die planare + EFERT beelde van elke pasiënt gerapporteer, waarna die planare + EFERT/RT beelde met die hulp van 'n radioloog gerapporteer is. Sekerheid oor die teenwoordigheid van hiperfunksionerende paratiroïedweefsel sowel as die sekerheid oor die lokalisering daarvan, is op 'n Likert-tipe skaal verkry. Interpretasie van planare + EFERT is vergelyk met die interpretasie van planare + EFERT/RT. Die impak van LDRT op twyfelagtige letsels en die aantal ektopiese letsels waargeneem, is ook bepaal. Resultate: Twintig pasiënte (M:13; F:7) met beelding tussen Februarie 2008 en Junie 2011 is ingesluit [gemiddelde ouderdom: 40 jaar (24-55)] . Die gemiddelde kreatinien was 687 μmol/l (169-1213), gemiddelde gekorrigeerde kalsium 2.55 mmol/l (1.95-3.33) en mediaan PTH 167 pmol/l (2.4->201). Vyf en dertig letsels is op planare en EFERT beelde waargeneem en was onveranderd na assessering van die LDRT-data. Sekerheid oor die teenwoordigheid van paratiroïedpatologie het verander in 5 pasiënte (5 letsels) met die toevoeging van LDRT. LDRT het die gemiddelde sekerheid van paratiroïedpatologie van 3.17 tot 3.29 verander (p = 0.16). Toevoeging van LDRT het die aantal twyfelagtige letsels van 18 (14 pasiënte) tot 14 (10 pasiënte) verminder (p = 0.13). Die byvoeging van LDRT het die lokalisering in 4 letsels (3 pasiënte) verander. Sekerheid oor die lokalisering van patologie is in 9 letsels (7 pasiënte) verander en die gemiddelde lokalisering betroubaarheidswaarde is verbeter van 4.2 tot 4.46 (p = 0.002) met LDRT. Met die byvoeging van LDRT het die aantal letsels geklassifiseer as ektopies van 5 tot 8 (p = 0.25) toegeneem.
Gevolgtrekking: In renale hiperparatiroïedisme het EFERT/RT die lokalisering van letsels wat op planare + EFERT beelding alleen waargeneem is, verander en die leser se vertroue om akkuraat te lokaliseer verbeter. EFERT/LDRT het geen bykomende voordeel bo EFERT in terme van die opsporing, sekerheid van paratiroïedpatologie of onderskeidingsvermoë tussen twyfelagtige teenoor nie-twyfelagtige paratiroïedletsels verleen nie. Met die byvoeging van LDRT is nie beduidend meer ektopiese letsels gevind nie. Terwyl die geringe verbetering in die sekerheid van lokalisering (met die byvoeging van LDRT) van twyfelagtige kliniese betekenis was, spekuleer ons dat die verandering en vermoedelik verbeterde lokalisering van letsels op EFERT/LDRT ʼn potensiële kliniese impak het in 'n beduidende aantal pasiënte. Die gebruik van EFERT/LDRT in die beelding van renale hiperparatiroïedisme wanneer chirurgie oorweeg word, word dus vir bogenoemde rede aanbeveel.
|
28 |
The Use of Single Photon Emission Computed Tomography to Indicate Neurotoxicity in Cases of Pesticide and Solvent ExposuresFincher, Cynthia Ellen 08 1900 (has links)
This study examined the effect of neurotoxic chemical exposures on brain processes using Single Photon Emission Computed Tomography (SPECT). A control group carefully screened for good health and minimal chemical exposures was compared to two groups of patients diagnosed with health problems following exposure to pesticides or to organic solvents.
|
29 |
Études expérimentale et numérique du colmatage de filtre plissé / Experimental and numerical study of pleated filters cloggingGervais, Pierre-Colin 19 February 2013 (has links)
L'utilisation de filtres plissés dans le domaine du traitement de l'air est extrêmement fréquente en raison de leur simplicité d'utilisation et de maintenance. Néanmoins, au cours du colmatage, la perte de charge augmente considérablement avec le dépôt de particules. Par conséquent le débit de filtration n'est plus maintenu et une détérioration des médias peut se produire. Il est essentiel de caractériser cette évolution en fonction des conditions opératoires pour mieux concevoir ces équipements. Les travaux ont consisté en une étude expérimentale de l'influence des conditions opératoires sur la géométrie du dépôt par des observations en Tomographie d'Émission MonoPhotonique. Une approche numérique a consisté, dans un premier temps, en une étude de la perméabilité de médias bien caractérisés afin de valider le code GeoDict. Dans un deuxième temps, une étude de la vitesse de l'air a été entreprise sur les médias plissés. La confrontation des résultats numériques avec les données expérimentales nous a permis une validation du code dans les gammes de propriétés des médias et de vitesses typiques. Concernant les médias bimodaux, l'acquisition rapide de données a permis de tester différentes corrélations analytiques afin de classifier les modèles existants d'une manière qui facilite leur utilisation. Si les résultats expérimentaux obtenus sur la localisation du dépôt préférentiel initial dans les filtres plissés sont encourageants, notamment vis-à-vis des simulations d'écoulement réalisées avec GeoDict, ceux issus des acquisitions sur les filtres précolmatés sont à prendre avec prudence et suggèrent d'apporter un certain nombre d'amélioration à notre technique / Pleated filters are widely used in air treatments because of the advantageous effective surface to overall dimension ratio they offer. Their major drawback though resides in their reduced lifetime which still needs to be controlled. Indeed, when clogging, the pressure drop considerably increases, the filtration flow is then no longer maintained which might lead to the deterioration of the media. It is then crucial to characterize the evolution of the pressure drop under operating conditions in order to best design these equipments. Part of our work consisted in studying how the operating conditions influence the geometry of the deposit. To do so, we used Single-Photon Emission Computed Tomography (SPECT), a non-destructive imaging technique that keeps intact the particle structuring. The visualization of aerosol deposit at the beginning of the filtration process allows observing preferential particle deposition on the whole height of the pleat. A numerical approach was used to study the permeability of bimodal fibrous media and we experimentally studied the local velocity as well as the biphasic flow inside pleated filter media. Comparison between experiments and simulations allowed us to validate the Geodict code for a wide range of media properties and velocities. Regarding bimodal fibrous media, the fast data acquisition has allowed testing several existing models which resulted in classifying them in a unique way. If the experimental results on the initial deposition in pleated filters are encouraging, those related to beforehand clogging point to several improvements regarding the technique we used
|
30 |
Estadiamento mediastinal pré-operatório em câncer de pulmão de não pequenas células utilizando fusão de imagem SPECT/TC com 99mTC-SESTAMIBI / Preoperative mediastinal staging in non-small cell lung cancer using image fusion SPECT/CT with 99mTc-SestamibiJuliana Muniz Miziara 18 April 2011 (has links)
INTRODUÇÃO: A avaliação do mediastino quanto à presença de metástases linfonodais é importante na escolha do tratamento dos pacientes com câncer de pulmão de não pequenas células. Apesar da tomografia computadorizada ser o exame de imagem de escolha no estadiamento do câncer de pulmão, tem limitações conhecidas quanto à avaliação dos linfonodos regionais. O objetivo deste trabalho é avaliar a acurácia do SPECT/TC utilizando o radiofármaco 99mTc-sestamibi no estadiamento linfonodal do mediastino em pacientes com diagnóstico de carcinoma de pulmão de não pequenas células e candidatos a tratamento cirúrgico. MÉTODOS: Foi realizada coleta prospectiva de dados de 41 pacientes entre dezembro de 2006 a fevereiro de 2009. Os pacientes foram submetidos à tomografia computadorizada de tórax e ao SPECT/TC com 99mTc-sestamibi no prazo máximo de 30 dias antes da cirurgia. O SPECT/TC foi considerado positivo quando havia captação no mediastino e a tomografia de tórax, quando havia linfonodos maiores do que 10 mm no menor eixo. Os resultados da interpretação do SPECT/TC com sestamibi e da TC de tórax foram comparados aos encontrados na patologia, definido como método padrão ouro. RESULTADOS: O SPECT/TC identificou de maneira correta seis dos 19 casos com envolvimento dos linfonodos hilares e um dos sete casos com metástases ganglionares no mediastino pela patologia. Os valores de sensibilidade, especificidade, valores de predição positivo e negativo para o 99mTc-sestamibi SPECT/TC na avaliação do hilo foram respectivamente de: 31,6%, 95,5%, 85,7% e 61,8% e para o mediastino de 14,3%, 97,1%, 50% e 84,6%. A tomografia de tórax encontrou sensibilidade para a análise dos linfonodos hilares e mediastinais de 47,4% e 57,1%, especificidade de 95,5%, e 91,2%, valores de predição positivo de 90% e 57,1% e negativo de 67,7% e 91,2%, respectivamente. CONCLUSÃO: Nos pacientes com câncer de pulmão de não pequenas células com doença inicial e ressecável o SPECT/TC com 99mTc-sestamibi no estadiamento linfonodal do mediastino apresentou baixa sensibilidade e acurácia, apesar da alta especificidade. O SPECT/TC não adicionou informações relevantes à TC de tórax, que poderiam justificar o seu emprego no estadiamento pré-operatório do carcinoma de pulmão de não pequenas células / INTRODUCTION: The proper nodal staging of non-small cell lung cancer is important to choose the best treatment modality. Although CT is the first-line imaging test for primary staging of lung cancer, it is well known its limitations on mediastinum nodal staging. The aim was to evaluate the accuracy of SPECT/CT using 99mTc-sestamibi in the nodal staging of patients with non-small cell lung cancer and potential candidates towards surgical treatment. METHODS: A prospective data collection of 41 patients was conducted from December 2006 to February 2009. The patients underwent chest CT and SPECT/CT with 99mTc-sestamibi within 30 days interval before surgery. SPECT/CT was considered positive when there was focal uptake of sestamibi in the mediastinum and CT scan when there was lymph nodes larger than 10 mm in short axis. The results of SPECT/CT and CT were correlated with pathology findings after surgery. RESULTS: SPECT/CT correctly identified six of 19 cases with involvement of hilar lymph nodes and one of seven cases with nodal metastases in the mediastinum. The sensitivity, specificity, positive and negative predictive value for 99mTc-sestamibi SPECT/CT in the assessment of the hilum were respectively: 31.6%, 95.5%, 85.7% and 61.8% and for the mediastinum 14.3%, 97.1%, 50% and 84.6%. Chest tomography showed a sensitivity of hilar and mediastinal lymph nodes of 47.4% and 57.1%, specificity of 95.5% and 91.2%, positive predictive value of 90% and 57.1% and negative predictive value of 67.7% and 91.2%, respectively. CONCLUSION: SPECT/CT with 99mTc-sestamibi showed very low sensitivity and accuracy for nodal staging of patients with non-small cell cancer despite its high specificity. Moreover, the performance of SPECT/CT added no relevant information compared to CT that could justify its use in the routine preoperative staging of non-small cell lung carcinoma
|
Page generated in 0.1041 seconds