• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 94
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • Tagged with
  • 97
  • 68
  • 57
  • 46
  • 44
  • 35
  • 26
  • 18
  • 17
  • 16
  • 16
  • 15
  • 14
  • 14
  • 12
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Estudo de multicamadas com anisotropia magnética perpendicular e sua aplicação em dispositivos emissores de luz polarizada em Spin

Zarpellon, Juliana 23 January 2012 (has links)
Resumo: A detecção eletrônica eficaz de corrente polarizada em spin se mantém um importante desafio na spintrônica com semicondutores. Dentre as estratégias de abordagem desse tema se destaca a utilização da detecção óptica das correntes polarizadas em spin através de dispositivos emissores de luz com estrutura diodo, denominados Spin-LED. De acordo com as regras de seleção ópticas, a eficiência da emissão de luz polarizada nesses dispositivos depende da magnetização do eletrodo ferromagnético injetor ser paralela ao eixo de quantização do poço quântico imerso no diodo formador do dispositivo. Neste trabalho é descrito e discutido o desenvolvimento de um dispositivo emissor de luz na faixa do infravermelho próximo fabricado a partir de uma heteroestrutura semicondutora do tipo GaAs/AlGaAs, cuja operação dispensa a necessidade de aplicação de um campo magnético externo. Isso foi obtido através da otimização do estado remanente de um eletrodo ferromagnético injetor com anisotropia magnética perpendicular. Os eletrodos ferromagnéticos foram desenvolvidos utilizando a técnica de pulverização catódica. Eles consistem de sistemas de multicamadas Co/Ni, Co/Pt e CoFeB/Pt, integrados à heteroestrutura semicondutora através de uma camada de MgO que atua como uma barreira túnel entre o ferromagneto e o semicondutor. Um estudo preliminar foi realizado para obter multicamadas constituídas de bicamadas formadas por Co ou CoFeB e um metal Ni ou Pt, com espessuras x e y, respectivamente, repetidas Z vezes. Esses estudos foram realizados sobre substratos de SiO2 amorfo recobertos por uma camada buffer de Pt de 20 nm de espessura. Para se obter a anisotropia magnética perpendicular foram variadas as espessuras x e y das camadas, bem como o número de repetições Z. A caracterização magnética foi realizada através de microscopia de força magnética, magnetometria de gradiente de força alternante e magnetometria SQUID. Análises de microscopia eletrônica de transmissão em seção transversal foram usadas para calibrar as espessuras e confirmar a modulação química dos depósitos nas multicamadas. Esses resultados experimentais não indicam a formação de ligas nas interfaces. Diversas espessuras da camada buffer e tipos diferentes de substratos foram usados tendo em vista a obtenção de propriedades físicas favoráveis a maior eficiência dos dispositivos Spin-LED. Dispositivos completos foram fabricados usando multicamadas Co/Pt com camadas buffer de Pt de 0,4 e 0,6 nm de espessura. Medidas de eletroluminescência revelaram que dispositivos com camada buffer de Pt com 0,4 nm de espessura apresentam uma emissão com polarização da luz de aproximadamente 1,5 %, com a aplicação de um campo magnético de 500 Oe, à temperatura de 20 K. Os dispositivos com camadas buffer de Pt com espessura de 0,6 nm não apresentaram polarização da luz, provavelmente devido à camada de Pt não estar totalmente polarizada magneticamente. Dispositivos com uma fina camada de Fe de 0,3 nm de espessura entre a camada de MgO e a camada buffer de Pt de 0,6 nm exibiram anisotropia perperpendicular ao plano e apresentam uma polarização da luz de 3,5 % sem a aplicação de campo magnético externo, à temperatura de 20 K, mostrando a possibilidade de se fabricar dispositivos Spin-LED sem a aplicação de um campo magnético externo. Os resultados deste trabalho mostram também que, além dos dispositivos Spin-LED, dispositivos como o VCSEL (Vertical-Cavity Surface-Emitting Lasers) podem ser desenvolvidos, abrindo um leque para outras aplicações tecnológicas.
12

Técnicas avançadas para caracterização de processos de transporte dependente do Spin

Nunes Neto, Oswaldo [UNESP] 20 March 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:30:18Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-03-20Bitstream added on 2014-06-13T21:00:48Z : No. of bitstreams: 1 nunesneto_o_me_bauru.pdf: 1131438 bytes, checksum: 09b76ed29dfc8f7b3da8ade09c2b1487 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Efeitos de campo magnético em materiais e dispositivos orgânicos não-magnéticos vêm sendo foco de grande destaque na comunidade científica. De maneira a melhor compreender tais fenômenos, este trabalho propôs-se à implementação das técnicas de Espectroscopia de impedância elétrica em correntes alternadad (EIE-AC) na Presença de Campo Magnético e de Ressonância Magnética Detectada Eletricamente (RMDE). Para a montagem dessas técnicas foram utilizados instrumentos convencionais disponiveis no laboratório e as suas arquiteturas foram planejadas para permitir a utilização desses instrumentos em outros sistemas de medida. Programas na plataforma Agilent Vee Pro 9.2 foram desenvolvidos para o controle e aquisição dos dados das medições. A validação do sistema de EIE-AC na Presença de Campo Magnético foi efetuada a partir de medidas em circuitos básicos e num diodo orgânico emissor de luz (OLED) à base da molécula de Alq3, o qual era sabido que este apresentava o efeito de magnetoresistência. A influência do campo magnético sobre o comportamento das impedâncias do OLED de medida só foi percebida significativamente a partir da aplicação de tensões contínuas acima de 4 V, as quais condicionavam o OLED em seu estado emissivo. O fenômeno de Magneto-Impedância foi verificado nessa amostra, sendo que os efeitos mais expressivos ocorreram nas impedâncias imaginárias e para a frequencia em torno de 20Hz. Um segundo efeito de campo magnético de longo prazo de ação sobre o comportamento da impedância da amostra também foi verificado e discutido. Dentre os mecanismos físicos que podem explicar os efeitos observados no OLED, destacam-se os processos de recombinação de carga, o aprisionamento de cargas em defeitos e a ocorrência de polarização magnética das moléculas constituintes do OLED / Magnetic Field Effects on non-magnetic organic materials and device have attracted the attention of the scientific community. In order to elucidate those phenomena, this work proposes the implantation of two advanced characterization techniques: Electrical Impedance Spectroscopy in Alternating Current (EIS-AC) in the presence of magnetic field; and electrically detected magnetic resonance (EDMR). Both techniques were implemented using conventional laboratory instruments. Computational routiness were developed with Agilent Vee Pro 9.2 in order to control and acquire data from the measuring instruments. the validation f eIS-AC system was performed by using basic electrical circuits and an Organic Light Emiting Diode (OLED) based in Alq3 molecule, which has the magnetoresistance effect. The magnetic field effects over impedances were only detected when the applied continuous voltage was above 4 V, from which the OLED is in its emiting state. The Magneto-Impedance phenomenon was evidenced in this sample mainly in the imaginary impedances and for frequencies around 20 Hz. A second magnetic field effect, with long time term action over the impedance behavior, was also verified and discussed. Among the possible physical mechanisms behind the magnetic effects, charge recombination process, charge trapping by deffects, and the magnetic polarization of the OLED active molecules are discussed
13

Fotofisica de polimeros emissores de luz : MEH-PPV

Cossiello, Rafael Di Falco, 1980- 03 August 2018 (has links)
Orientador: Teresa Dib Zambon Atvars / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Quimica / Made available in DSpace on 2018-08-03T21:54:50Z (GMT). No. of bitstreams: 1 Cossiello_RafaelDiFalco_M.pdf: 1572837 bytes, checksum: 19e63ede7b38e238cbb9b8b3d9a68b93 (MD5) Previous issue date: 2003 / Mestrado
14

Fontes de luz na micropropagação de clones híbridos de Corymbia / Sources of light in micropropagation of Corymbia hybrid clones

Souza, Denys Matheus Santana Costa 19 February 2018 (has links)
Submitted by Reginaldo Soares de Freitas (reginaldo.freitas@ufv.br) on 2018-06-04T18:24:37Z No. of bitstreams: 1 texto completo.pdf: 1088198 bytes, checksum: 9e47c35efa990076df569a8a2c0f1e94 (MD5) / Made available in DSpace on 2018-06-04T18:24:37Z (GMT). No. of bitstreams: 1 texto completo.pdf: 1088198 bytes, checksum: 9e47c35efa990076df569a8a2c0f1e94 (MD5) Previous issue date: 2018-02-19 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / A importância das espécies do gênero Corymbia e de seus híbridos interespecíficos tem sido evidenciada nos programas de silvicultura, principalmente devido à sua qualidade da madeira e capacidade de adaptações as condições ambientais. Essas considerações têm estimulado o desenvolvimento de protocolos mais eficientes na propagação vegetativa necessária para a clonagem destas plantas. O presente estudo teve como objetivo geral a micropropagação de clones híbridos de Corymbia torelliana x C. citriodora e Corymbia citriodora x C. torelliana, e especificamente avaliar: i) o efeito da fonte de luz na introdução in vitro de clones híbridos de Corymbia torelliana x C. citriodora e Corymbia citriodora x C. torelliana; ii) o efeito da fonte de luz, regulador de crescimento BA e o número de subcultivos na fase de multiplicação in vitro de clones híbridos de Corymbia torelliana x C. citriodora e Corymbia citriodora x C. torelliana, e; iii) o efeito da fonte de luz, trocas gasosas e concentração de sacarose no alongamento in vitro e porcentagem de enraizamento e sobrevivência in vitro e ex vitro de microestacasde clones híbridos de Corymbia torelliana x C. citriodora e Corymbia citriodora x C. torelliana. O material experimental utilizado para obtenção dos explantes foi proveniente de minicepas de três clones híbridos de Corymbia torelliana x C. citriodora (TC01, TC02, TC03) e um de Corymbia citriodora x C. torelliana (CT01). Os experimentos in vitro foram conduzidos no Laboratório de Cultura de Tecidos II do Instituto de Biotecnologia Aplicada à Agropecuária (BIOAGRO), da Universidade Federal de Viçosa (UFV), localizado no município de Viçosa/MG, e o experimentos ex vitro foram conduzidos no Viveiro de Pesquisas do Departamento de Engenharia Florestal da UFV. Com base nos resultados obtidos, pode-se concluir que: i) o uso da fonte de luz LEDs correspondeu aos melhores resultados, para as características avaliadas na introdução in vitro; ii) o uso de LEDs vermelho azul obteve os melhores resultados, para os clones analisados na multiplicação in vitro; os explantes apresentaram resposta eficiente ao estimulo do regulador de crescimento BA, na concentração de 0,5 mg L- 1 para os clones Corymbia torelliana x C. Citriodora (TC01, TC02 e TC03) e 1,0 mg L- 1 para o clone Corymbia citriodora x C. torelliana (CT01), promovendo maior número de brotações; quanto ao número de subcultivos os melhores resultados foi diante do nono subcultivo, no qual conseguiu atingir maiores valores para o número de brotos por explante e vigor; iii) o uso de LEDs vermelho azul proporcionou a melhor resposta, para os clones analisados no alongamento e enraizamento in vitro; a concentração de 15g L -1 de sacarose apresentou os melhores resultados diante das variáveis analisadas, concentração essa que apresenta redução desse componente no meio nessas condições de cultivo; os explantes alongados (microestacas) apresentaram melhor resposta ao enraizamento e sobrevivência das plantas obtidas na condição in vitro. / The importance of the species belonging to the genus Corymbia and its interspecific hybrids has been highlighted in the silviculture programs, mainly due to its wood quality and adaptability to the environmental conditions. These considerations have stimulated the development of an efficient protocol for the vegetative propagation necessary for the cloning of these plants. The present study had the general objective of micropropagating hybrid clones of Corymbia torelliana x C. citriodora and Corymbia citriodora x C. torelliana, and specifically to evaluate: i) the effect of the light source on the in vitro introduction of hybrid clones of Corymbia torelliana x C. citriodora and Corymbia citriodora x C. torelliana; ii) the effect of the light source, growth regulator BA and the number of subcultures on the in vitro multiplication phase of hybrid clones of Corymbia torelliana x C. citriodora and Corymbia citriodora x C. torelliana, and; iii) the effect of light source, gas exchange and sucrose concentration on in vitro elongation and percentage of rooting and in vitro and ex vitro survival of micro-cuttings of hybrid clones of Corymbia torelliana x C. citriodora and Corymbia citriodora x C. torelliana. The experimental material used to obtain the explants was from mini-stumps of three hybrid clones of Corymbia torelliana x C. citriodora (TC01, TC02, TC03) and one of Corymbia citriodora x C. torelliana (CT01). The in vitro experiments were conducted at the Tissue Culture Laboratory II of the Institute of Applied Biotechnology for Agriculture, Federal University of Viçosa (UFV), Viçosa/MG, and the ex vitro experiments were conducted at the Research Nursery of the Forest Engineering Department of UFV. Based on the results, it can be concluded that: i) the use of the LED light source corresponded to the best results, for the characteristics evaluated in the in vitro introduction; ii) the use of red blue LEDs generated the best results for the clones analyzed in the in vitro multiplication; the explants presented efficient response to BA growth regulator at 0.5 mg L-1 concentration for Corymbia torelliana x C. Citriodora clones (TC01, TC02 and TC03) and 1.0 mg L-1 for the clone Corymbia citriodora x C. torelliana (CT01), promoting greater number of shoots; as to the number of subcultures the best results were in the ninth subculture, in which it was able to reach higher values for the number of shoots per explant and vigor; iii) the use of red blue LEDs provided the best response, for the clones analyzed in the in vitro elongation and rooting; the concentration of 15 g L-1 of sucrose presented the best results in relation to the analyzed variables, a concentration that shows a reduction of this component in the medium under these conditions of cultivation; the elongated explants (micro- shoots) showed a better response to the rooting and survival of the plants obtained in the in vitro condition.
15

Difusão de Sn em GaAs usando fonte de SiO2 dopado

Santos, Thebano Emilio de Almeida 13 February 1986 (has links)
Orientador: Mauro Monteiro Garcia de Carvalho / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Fisica Gleb Wataghin / Made available in DSpace on 2018-07-17T12:29:21Z (GMT). No. of bitstreams: 1 Santos_ThebanoEmiliodeAlmeida_M.pdf: 1326878 bytes, checksum: 3b536c470b96f98b7b0edc42c8119769 (MD5) Previous issue date: 1986 / Resumo: É feito um estudo sobre difusão de estanho em GaAs dopado com Cr (semi-isolante) e tipo p através da técnica que utiliza filme de SiO2:Sn depositado sobre a amostra. Neste estudo, evidencia-se as influências da conversão do GaAs dopado com Cr e das vacâncias de Ga. Os resultados obtidos são comparados com os da literatura / Abstract: Not informed. / Mestrado / Física / Mestre em Física
16

Análise da eficácia clareadora e dos efeitos adversos provocados pelo uso da luz violeta no clareamento dental /

Gallinari, Marjorie Oliveira January 2019 (has links)
Orientador: André Luiz Fraga Briso / Resumo: Pesquisadores tem proposto um clareamento dentário apenas com a irradiação da Luz violeta (VIO), sem a necessidade do gel clareador. Portanto foi o objetivo deste trabalho avaliar in vitro e in vivo este novo tratamento associado com diferentes concentrações de peróxido de hidrogênio (PH) quanto a sua eficácia clareadora e os possíveis efeitos adversos. Para o estudo in vitro, foram selecionados 567 (n=67) dentes e distribuídos em 9 grupos: Sem Gel(SG)-Sem Luz(SL), PH17,5%-SL, PH35%-SL, SG-LED/Laser(LED), PH17,5%-LED, PH35%-LED, SG-VIO, PH17,5%-VIO e PH35%-VIO. A aplicação dos géis seguiu as recomendações do fabricante. O LED foi irradiada 3 vezes de 3 minutos, a VIO foi irradiada 3 vezes de 7 minutos. Após os procedimentos clareadores, foram realizadas as análises de alteração cromática superficial e intensidade de fluorescência (n=10), considerando 5 tempos de análise (T0-inicial, T1-1º sessão, T2-2º sessão, T3-3º sessão, T4-14 dias após), alteração de cor em profundidade (n=15), condutância hidráulica (n=10), difusão do PH (n=10), viabilidade celular (n=8) e a variação da temperatura intrapulpar (n=10). Os dados foram submetidos à testes estatísticos adequados para cada tipo de análise. A VIO quando utilizado isoladamente proporcionou alterações cromáticas superficiais e em profundidade, mas seu efeito foi estatisticamente menor do que o proporcionado pelo gel clareador. Na fluorescência, o T1 e T3 do PH35%-SL foram diferentes. A difusão do PH e a permeabilidade dentária, ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Researchers have proposed tooth whitening only with the irradiation of violet light (VIO), without the need for whitening gel. Therefore, the objective of this study was to evaluate in vitro and in vivo this new treatment associated with different concentrations of hydrogen peroxide (PH) for its bleaching efficacy and possible adverse effects. For the in vitro study, 567 (n = 67) teeth were selected and divided into 9 groups: No Gel (SG) -Without Light (SL), PH17.5% -SL, PH35% -SL, SG-LED / Laser (LED), PH17.5% -LED, PH35% -LED, SG-VIO, PH17.5% -VIO, and PH35% -VIO. The application of the gels followed the manufacturer's recommendations. The LED was applied3 times 3 minutes, the VIO was applied3 times 7 minutes. After the bleaching procedures, superficial chromatic alteration and fluorescence intensity analyzes were performed (n = 10), considering 5 analysis times (initial T0, T1-1st session, T2-2nd session, T3-3th session, T4-14 days later), depth color change (n = 15), hydraulic conductance (n = 10), PH diffusion (n = 10), cell viability (n = 8) and intrapulp temperature variation (n = 10) ). Data were submitted to appropriate statistical tests for each type of analysis. VIO when used alone provided superficial and deep color changes, but its effect was statistically smaller than that provided by the whitening gel. In fluorescence, the T1 and T3 of PH35% -SL were different. PH diffusion and dental permeability, the PH35% groups presented the highest values, being potentiate... (Complete abstract click electronic access below) / Doutor
17

Estudo das propriedade elétricas e luminescentes de blendas poliméricas aplicadas a células eletroquímicas emissoras de luz /

Canassa, Thalita Antoniassi. January 2017 (has links)
Orientador: Lucas Fugikawa Santos / Banca: Roberto Mendonça de Faria / Banca: Giovani Gozzi / Resumo: Células eletroquímicas emissoras de luz (LECs) são dispositivos eletroluminescentes orgânicos que apresentam várias vantagens em relação aos tradicionais diodos emissores de luz poliméricos (PLEDs). Em geral, as LECs apresentam uma baixa tensão de operação, que é independente da função trabalho do eletrodo e uma maior eficiência devido à injeção de carga equilibrada dos eletrodos. A camada ativa de LEC geralmente compreende uma mistura de um polímero conjugado eletroluminescente e um eletrólito polimérico sólido, ocorrendo uma combinação de transporte iônico e eletrônico. Neste trabalho, estudamos as propriedades elétricas e ópticas do poli (3-hexiltiofeno), P3HT; poli (9,9-di-n-octilfluorenil-2,7-diil), PFO; poli [2-metoxi-5- (3 ', 7'-dimetiloctiloxi) -1,4-fenilenovinileno], MDMO-PPV e poli (óxido de etileno), PEO, essas blendas foram utilizadas para aplicações em LEC poliméricas. O estudo baseou-se nos resultados das medidas de corrente e luminância vs. tensão (I x V e L x V), espectroscopia no infravermelho (FTIR), espectroscopia na região do UV e do visível (UV-Vis) e espectroscopia de fluorescência de dispositivos produzidos em diferentes composições de blendas. As LECs foram produzidos em uma configuração do tipo sanduíche, usando filmes finos poliméricos com espessura variando entre 250 nm a 600 nm. O eletrólito polimérico da blenda compreende uma mistura de PEO com sal de trifluorometanossulfonato de lítio (triflato de lítio, CF3SO3Li), cuja relação de concentração... / Abstract: Light emitting electrochemical cells (LECs) are organic electroluminescent devices which present several advantages over traditional polymer light-emitting diodes (PLEDs). In general, LECs presents a low operation voltage, which is independent on the electrode work function and a higher efficiency due to the balanced charges injection from the electrodes. The active layer of LECs usually comprises a blend of a conjugated electroluminescent polymer and a solid polymeric electrolyte. In this work, we studied the electrical and optical properties of poly(3-hexylthiophene), P3HT; poly(9,9-di-n-octylfluorenyl-2,7-diyl), PFO; poly[2-methoxy-5-(3′,7′-dimethyloctyloxy)-1,4-phenylenevinylene], MDMO-PPV, and poly(ethylene oxide), PEO, blends for polymeric LECs applications. The study was based on results from current and luminance vs. voltage (I x V and L x V), FTIR, UV-Vis and Fluorescence spectroscopy measurements of devices produced at different blend compositions. The LECs were produced in a sandwich type configuration, by using polymeric thin films with thickness varying from 250 nm to 600 nm. The blend polymeric electrolyte comprises a PEO mixture with lithium trifluoromethanesulfonate salt (lithium triflate, CF3SO3Li), which concentration ratio (salt:PEO) varied from null to 10% (w:w). The results showed that electric bipolar behavior is achieved by increasing the salt concentration (above 5%), resulting in improved device performance. The UV-vis absorption and fluorescence ... / Mestre
18

Desenvolvimento e avaliação de um sistema de filtragem com reversão de fluxo de alta frequência / Development and assessment of filtration in irrigation system with high frequency reversal flow

Pinto, Marinaldo Ferreira 18 June 2013 (has links)
A obstrução de emissores tem sido um entrave para a microirrigação. Porém, tem-se notado poucos estudos relativos ao desenvolvimento de equipamentos que auxiliam na prevenção da obstrução de emissores nos últimos anos. Os estudos realizados nesta linha estão geralmente ligados à caracterização dos sistemas em uso. O objetivo deste trabalho foi desenvolver um sistema de filtragem com reversão automática de fluxo, de alta frequência. O sistema foi concebido para operar com água de baixa qualidade, com inversão de fluxo e limpezas automáticas e com volume mínimo de água para realização das limpezas. As decisões do controlador do sistema de filtragem têm como base a perda de carga, obtida por meio de transdutores de pressão instalados na entrada e na saída do sistema. O protótipo final é composto, basicamente, por três filtros de tela e onze válvulas solenoides controladas eletronicamente. Determinou-se a curva de perda de carga em função da vazão, a eficiência de retenção e o volume mínimo de água para limpeza dos filtros. A eficiência de retenção de partículas foi determinada em delineamento experimental inteiramente aleatorizado em esquema fatorial, sendo testados três fatores: tempo de reversão (15 e 30 s); incremento da perda de carga (25 e 50%) e concentração de sólidos (500 e 1000 mg L-1). A eficiência de retenção de sólidos totais foi de 71,7 e 78,3% para as concentrações de 500 e 1000 mg L-1, respectivamente, tendo apresentado diferença significativa a 1% de probabilidade. Entretanto, a eficiência retenção de sólidos maiores que 50 ?m (Ed > 50) foi de 98,6 ± 0,7%, não sendo significante para nenhum dos tratamentos ao nível de significância de 1%. O volume médio de água despendido durante as limpezas foi de 5,39 L por limpeza, que representou um volume de água de limpeza por volume de água filtrada de 8,0 e 12,6 L m-3, para as concentrações de 500 e 1000 mg L-1, respectivamente. Os valores de eficiência energética do sistema de filtragem variaram de 80 a 90% para a vazão de 2 m3 h-1 com pressão de entrada entre 15 a 40 mca. As limpezas do sistema de filtragem não foram totalmente eficazes na retomada da perda de carga, com tendência de aumento com o tempo. A inversão de fluxo com frequências de 11,11 e 22,22 mHz influenciou na evolução da perda de carga do sistema de filtragem, tornando-a mais lenta que a evolução para o sistema funcionando sem inversão de fluxo. Considerou-se que o sistema de filtragem desenvolvido apresentou potencial para filtragem da água de irrigação com baixa qualidade, porém necessita de manutenções periódicas para limpeza do elemento filtrante. A perda de carga admissível do sistema de filtragem deve ser o valor mais restritivo entre o critério de desempenho de retenção de partículas e o de variação de vazão do sistema de irrigação. / Emitters clogging have been a barrier to trickle irrigation. Just a few studies have been performed concerning equipments which assist in preventing emitters clogging in recent years, especially regarding to development equipment. Studies carried out on this issue are usually linked to the characterization of systems in use. The aim of this study was to develop a filtering system with automatic flow reversal of high frequency. The system is designed to operate with low quality water, with reverse flow and automatic cleanings and with minimum volume of water to perform the cleaning. Decisions by the controller of the filtration system are based on head loss, obtained by pressure transducers installed at the upstream and downstream of the system. The final prototype consists of three screen filters and eleven electronically controlled solenoid valves. The curve of head loss was determined as a function of water flow, retention efficiency and minimum volume of water required for cleaning the filters. The efficiency in particle retention was determined following a completely randomized experimental design in a factorial scheme in which three factors were tested: reversal time (15 and 30 s) increase in head loss (25 and 50%) and solids concentration (500 and 1000 mg L-1). The total solids retention efficiency was 71.7 and 78.3% for concentrations of 500 and 1000 mg L-1, respectively, presenting a significant difference at 1%. However, when analyzing the retention efficiency of solids larger than 50 ?m (Ed> 50), none of the treatments was significant at 1%, whose efficiency was 98.6 ± 0.7%. The mean volume of water expended during the cleaning was 5.39 L. It represented a volume of water for cleaning per volume of filtered water from 8.0 and 12.6 L m-3, to concentrations of 500 and 1000 mg L-1, respectively. The energy efficiency values of filtering system ranged from 80 to 90% considering flow rate of 2 m3 h-1 and inlet pressure ranging from 15 to 40 mca. The filtering system cleaning was not totally effective in reestablishing the head loss, with an upward trend over time. The reverse flow with frequency of 11.11 and 22.22 mHz influenced the head loss evolution of the filtration system, making it slower than the trend for the system running without flow reversal. The developed filtration system has potential for filtering low quality irrigation water, but it requires periodic maintenance to clean the filter element. The allowable head loss of the filter system should be the most restrictive value between the criterion of particle retention performance and the flow variation of the irrigation system because of the increase in head loss in the filters.
19

Medida absoluta da atividade de 14C pelos métodos CIEMAT/NIST, TDCR e em sistema de coincidência 4πβ-γ / Primary standardization of C-14 by means of CIEMAT/NIST, TDCR and 4πβ-γ methods

Kuznetsova, Maria 28 September 2016 (has links)
Neste trabalho foi padronizada uma solução de 14C emissor beta puro com energia máxima de 156 keV, por meio de três diferentes métodos: CIEMAT/NIST e TDCR (triple-to-double coincidence ratio) em sistemas de cintilação líquida e pelo método do traçador, em sistema de coincidências 4πβ-γ. O sistema de cintilação líquida TRICARB, equipado com dois tubos fotomultiplicadores, foi usado para aplicação do método CIEMAT/NIST, usando um padrão de 3H emissor beta puro com energia máxima de 18,7 keV como traçador de eficiência. O sistema de cintilação líquida HIDEX 300SL, equipado com três tubos fotomultiplicadores, foi utilizado para as medidas pelo método TDCR. As amostras de 14C e 3H, medidas nos sistemas de cintilação foram preparadas usando-se três coquetéis cintiladores comerciais Ultima Gold, Optiphase Hisafe3 e InstaGel-Plus a fim de comparar seu desempenho nas medidas.Todas as amostras foram preparadas com 15 mL de coquetel cintilador, em frascos de vidro com baixa concentração de potássio. Alíquotas conhecidas de solução radioativa foram depositadas nos coquetéis cintiladores. Para a variação do parâmetro indicador de quenching, foram utilizados: um carregador de nitro metano e 1 mL de água destilada. Para a padronização pelo método do traçador no sistema de coincidências 4πβ-γ, foi utilizado 60Co como emissor beta gama. As medidas foram feitas no sistema de coincidências por software SCS, usando discriminação eletrônica para alterar a eficiência beta. O comportamento da curva de extrapolação foi predito por meio do código Esquema, que utiliza a técnica de Monte Carlo. Os resultados da atividade da solução de 14C obtida pelos três métodos utilizados mostraram uma boa concordância dentro da incerteza experimental. / In this work, the primary standardization of 14C solution, which emits beta particles of maximum energy 156 keV, was made by means of three different methods: CIEMAT/NIST and TDCR (triple-to-double coincidence ratio) methods in liquid scintillation systems and the tracing method, in the 4πβ-γ coincidence system. TRICARB LSC (Liquid Scintillator Counting) system, equipped with two photomultipliers tubes, was used for CIEMAT/NIST method, using a 3H standard that emits beta particles with maximum energy of 18.7 keV, as efficiency tracing. HIDEX 300SL LSC system, equipped with three photomultipliers tubes, was used for TDCR method. Samples of 14C and 3H, for the liquid scintillator system, were prepared using three commercial scintillation cocktails, UltimaGold, Optiphase Hisafe3 and InstaGel-Plus, in order to compare the performance in the measurements. All samples were prepared with 15 mL scintillators, in glass vials with low potassium concentration. Known aliquots of radioactive solution were dropped onto the cocktail scintillators. In order to obtain the quenching parameter curve, a nitro methane carrier solution and 1 mL of distilled water were used. For measurements in the 4πβ-γ system, 60Co was used as beta gamma emitter. SCS (software coincidence system) was applied and the beta efficiency was changed by using electronic discrimination. The behavior of the extrapolation curve was predicted with code ESQUEMA, using Monte Carlo technique. The 14C activity obtained by the three methods applied in this work was compared and the results showed to be in agreement, within the experimental uncertainty.
20

Determinação da taxa de desintegração dos emissores beta puros P-32 e Sr-90/Y-90 em sistema de cintilação líquida / Determination of desintegration rate of the beta pure emitters 32P and 90Sr 90Y in liquid scintillation system

Marques, Caio Pinheiros 09 August 2017 (has links)
No presente trabalho, foram padronizados os radionuclídeos emissores beta puros 32P e 90Sr 90Y. O primeiro foi medido nos sistemas comerciais de cintilação líquida TRICARB 2100 e HIDEX 300SL, que utilizam, respectivamente, dois e três tubos fotomultiplicadores. A análise dos dados adquiridos pelo primeiro e segundo sistemas foi realizada pela aplicação dos métodos CIEMAT/NIST e TDCR, respectivamente. Para padronização da solução de 32P, foi também utilizado o sistema 4πβ empregando-se a técnica de autoabsorção. A solução de 90Sr 90Y foi padronizada no sistema de cintilação líquida, HIDEX 300SL, pelo método TDCR, e pela técnica do traçador, no sistema de coincidência 4πβ-γ o qual é composto por um contador proporcional à gás fluente, acoplado a dois cristais cintiladores de NaI(Tl). A taxa de desintegração foi determinada pela técnica de extrapolação, por meio de absorvedores externos. Para aplicação da técnica do traçador, foi utilizada uma solução de 60Co, emissor beta-gama previamente padronizado no sistema de coincidências. Foi realizada, também, uma simulação dos processos de detecção neste sistema por meio do programa ESQUEMA, que, pela simulação de Monte Carlo, prediz a curva de extrapolação da eficiência. Os resultados obtidos para o 32P nos sistemas utilizados apresentaram um bom acordo, dentro das incertezas experimentais, bem como os obtidos para o 90Sr 90Y, em sistema de cintilação e sistema de coincidência, apresentando bom acordo, dentro das incertezas experimentais. O resultado obtido pela técnica de Monte Carlo apresentou boa concordância com o valor obtido com o sistema de coincidência. Os resultados indicam a qualidade e boa precisão dos sistemas de detecção utilizados neste trabalho, quando empregados para fins metrológicos. / In the present work, pure beta emitters radionuclides 32P and 90Sr - 90Y were standardized. The first one was measured in commercial liquid scintillation systems TRICARB 2100 and HIDEX 300SL, which use, respectively, two and three photomultiplier tubes. The analysis of the data acquired by the first and second systems was performed using the CIEMAT / NIST and TDCR methods, respectively. For standardization of the 32P solution, the 4πβ system was also used, using the self-absorption technique. The 90Sr - 90Y solution was standardized in the liquid scintillation system, HIDEX 300SL, by the TDCR method, and by the tracer technique, in the coincidence system 4πβ-γ which is composed by a proportional counter to the flowing gas, coupled to two NaI(Tl) scintillation crystals. The rate of disintegration was determined by the extrapolation technique, by means of external absorbers. For the application of the tracer technique, a 60Co solution, a beta-gamma emitter previously standardized in the coincidence system, was used. It was also performed a simulation of the detection processes in this system through the program ESQUEMA, which, by Monte Carlo simulation, predicts the efficiency extrapolation curve. The results obtained for the 32P in the systems used presented a good agreement, within the experimental uncertainties, as well as those obtained for the 90Sr - 90Y, in scintillation system and coincidence system, showing good agreement, within the experimental uncertainties. The result obtained by the Monte Carlo technique showed good agreement with the value obtained with the coincidence system. The results indicate the quality and good accuracy of the detection systems used in this work, when used for metrological purposes.

Page generated in 0.0696 seconds