Spelling suggestions: "subject:"endodontically created dolars"" "subject:"endodontically created colars""
1 |
Resist?ncia ? fratura de molares tratados endodonticamente restaurados com diferentes t?cnicas diretasZambiasi, Bianca Soares 26 January 2018 (has links)
Submitted by PPG Odontologia (odontologia-pg@pucrs.br) on 2018-06-04T18:19:16Z
No. of bitstreams: 1
BIANCA_SOARES_ZAMBIASI_DIS.pdf: 758503 bytes, checksum: 8be0192f396b8b0f4c6df98b83a9d972 (MD5) / Rejected by Sheila Dias (sheila.dias@pucrs.br), reason: Devolvido devido ? falta de capa institucional no arquivo em PDF. on 2018-06-14T17:04:02Z (GMT) / Submitted by PPG Odontologia (odontologia-pg@pucrs.br) on 2018-06-26T12:16:19Z
No. of bitstreams: 1
BIANCA_SOARES_ZAMBIASI_DIS.pdf: 578649 bytes, checksum: c63b0e7591fc3dce9a38312f414e4e43 (MD5) / Approved for entry into archive by Sheila Dias (sheila.dias@pucrs.br) on 2018-07-02T16:48:43Z (GMT) No. of bitstreams: 1
BIANCA_SOARES_ZAMBIASI_DIS.pdf: 578649 bytes, checksum: c63b0e7591fc3dce9a38312f414e4e43 (MD5) / Made available in DSpace on 2018-07-02T16:57:34Z (GMT). No. of bitstreams: 1
BIANCA_SOARES_ZAMBIASI_DIS.pdf: 578649 bytes, checksum: c63b0e7591fc3dce9a38312f414e4e43 (MD5)
Previous issue date: 2018-01-26 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior - CAPES / Aims: To evaluate, in vitro, the fracture resistance and the pattern of failure of endodontically treated molars restored with different direct restorative techniques. Materials and methods: 70 third healthy molars extracted were divided into 7 groups (n = 10): (all groups except H received root canal treatment) H-sound; Z250PT ? horizontally transfixed fiberglass post + Z250 composite resin; Z250FO ? Z250 + occlusal fiberglass tape; Z250FP ? Z250 + fiberglass tape along the floor of the pulp chamber; PREP-only cavity preparation; COL ?
Restored with Coltosol. After the restorative procedures, the samples were subjected to 250,000 cycles of mechanical testing fatigue under 200N. Right after, the samples were submitted to the fracture resistance testing and the analysis of the type of fracture which were classified as follows: Pulp chamber floor (non-repairable) or cusps (repairable). Results: (means (N) followed by the same letter do not present statistical difference to ANOVA and Tukey (p > 0.05): H 3832A; Z250PT 2726B; Z250FO 1647C; Z250FP 1548C; Z250 1622C; PREP 514D; COL 450D. Conclusion: The restorative technique that presents higher resistance to the fracture as well as higher percentage of repairable failures is
horizontal transfixing with fiberglass post, Z250PT group. The insertion of fiberglass tape into the composite resin did not present improvement in the resistance, nor in the fracture pattern, when compared to the use of traditional composite resin. / Objetivo: Avaliar, in vitro, a resist?ncia ? fratura e o padr?o de falha de dentes tratados endodonticamente restaurados com diferentes t?cnicas restauradoras diretas. Materiais e M?todos: Setenta terceiros molares h?gidos extra?dos foram divididos em 7 grupos (n=10) assim distribu?dos: (todos os grupos exceto H receberam endodontia) H- h?gidos; Z250PT ? pino de fibra de vidro transfixado horizontalmente + resina composta Z250; Z250FO ? Z250+fita de fibra de vidro oclusal; Z250FP ? Z250 + fita de fibra de vidro junto ao assoalho da c?mara pulpar; PREP ? apenas preparo cavit?rio; COL ? restaurado com material provis?rio Coltosol. Ap?s o t?rmino das restaura??es as amostras foram submetidas a 250 mil ciclos de fadiga mec?nica sob 200N. Em seguida, foi realizado o ensaio de resist?ncia ? fratura e a an?lise do tipo de fratura p?sensaio as quais foram classificadas em: assoalho da c?mara pulpar (irrepar?vel) ou c?spides (repar?vel). Resultados: (m?dias (N) seguidas de mesma letra n?o apresentam diferen?a estat?stica para ANOVA e Tukey (p>0,05): H 3832A;
Z250PT 2726B; Z250FO 1647C; Z250FP 1548C; Z250 1622C; PREP 514D; COL 450D. Conclus?o: A t?cnica restauradora que apresenta maior resist?ncia ? fratura. bem como maior percentual de falhas repar?veis ? a transfixa??o horizontal com pino de fibra de vidro, grupo Z250PT. A inser??o de fita de fibra de vidro na resina composta n?o apresentou melhora na resist?ncia, nem no padr?o de fratura, quando comparado a utiliza??o de resina composta tradicional.
|
2 |
Efeito do número de pinos de fibra de vidro na resistência à fratura, deformação estrutural e distribuição de tensão em molares tratados endodonticamenteBarcelos, Luciana Mendes 12 February 2016 (has links)
Conselho Nacional de Desenvolvimento Científico e Tecnológico / The aim of this study was to evaluate the biomechanical effect of the presence
and number of fibreglass post in endodontically treated molars restored with
composite resin. 45 human molars were selected, included in polystyrene resin
cylinders with simulation of the periodontal ligament and endodontically treated.
These teeth were randomized into three groups (n = 15): Wfgp, without
fibreglass post and restored with Filtek Z350 XT; 1fgp, 1 fiberglass post Exact
#2 cemented in the distal root with RelyX U200 and restored with Z350XT; and
2fgp, 2 fiberglass posts cemented with RelyX U200, one in the distal root and
the other in the mesiobuccal root, restored with Z350XT. The specimens were
submitted to mechanical fatigue with axial load of 50N. The tooth remaining
deformation was measured using extensometers (n = 10) during occlusal
loading of 100N and then until fracture. The other teeth (n = 5) were used to
calculate the modulus of elasticity (GPa) and Vickers hardness (VH, N/mm2) of
the enamel, dentin composite resin and fiberglass post in two positions:
parallelly and transversally to the long axis of the post. The stress distribution
was analyzed using three dimensional finite elements model, generated from
micro-CT image of an intact tooth with its geometry similar of those used in the
in vitro study. The calculated mechanical properties were used to characterize
models of finite element analysis. The data of deformation and fracture
resistance were tested for normality (Shapiro-Wilk) and equivalence of
variances (test Levene), followed by parametric statistical tests appropriated for
each test. One way Anova was performed for the axial compressive strength
values, tooth remaining deformation and fracture resistance. Multiple
comparisons were performed using Tukey test. The mean fracture data were
submitted to the Chi-square test. Factorial analysis of variance on two factors
was carried out considering as factors in study: the tooth surface deformation (B
and L) and rehabilitation technique. All tests done had significance level α =
0.05 and all analyses were performed with the statistical program Sigma Plot
version 13.1 (Systat Software, San Jose, CA, USA). The use of two fiber glass
posts resulted in lower fracture resistance than the groups without fiber glass
- 22 -
post and with one fiber glass post. During occlusal loading of 100N lingual
surface of the remaining tooth showed higher deformation for all groups. The
absence of fiber glass post resulted in significantly higher values of stress in the
root and more irreparable fracture modes than the other groups. The use of a
fiber glass post resulted in better ratio deformation/fracture resistance. The
concentration of stress in the furcation area was slightly reduced with use of
fiber glass post. It is concluded that the use of one fiber glass post to
rehabilitated molars with direct composite resin showed higher resistance to
fracture than the use of two fiberglass posts, lower tooth remaining
deformation, better stress distribution and failure pat more repairable when
compared to molars restored without use of fiber-glass post / O objetivo deste trabalho foi avaliar o efeito biomecânico da presença e do
número de pinos de fibra de vidro em molares tratados endodonticamente e
restaurados de forma direta com resina composta. Quarenta e cinco molares
humanos foram selecionados, incluídos em cilindros de resina de poliestireno
com simulação do ligamento periodontal e tratados endodonticamente. Estes
dentes foram randomizados em três grupos (n=15): Spfv, sem pino de fibra de
vidro, restaurado com Filtek Z350XT; 1pfv, 1 pino de fibra de vidro Exacto Nº 2
cimentado no canal distal com RelyX U200 restaurado com Z350XT; e 2pfv, 2
pinos de fibra de vidro Exacto Nº 2 cimentados com RelyX U200, um no canal
distal e o outro no mesio-vestibular restaurado com Z350XT. As amostras
foram submetidas à fadiga mecânica com carregamento axial de 50N. A
deformação do remanescente foi mensurada usando extensômetros (n=10)
durante o carregamento oclusal de 100N e em seguida até o momento de
fratura. Os demais dentes (n=5) foram usados para calcular o módulo de
elasticidade (E, GPa) e dureza Vickers (VH, N/mm2) do esmalte, dentina, resina
composta e pino de fibra de vidro em duas posições: paralelamente e
transversalmente ao longo eixo do pino. A distribuição de tensões foi analisada
usando modelo tridimensional de elementos finitos gerado a partir de imagem
de micro-CT de um dente hígido com medidas e geometrias representativo das
amostras usadas na etapa experimental. Às propriedades mecânicas
calculadas foram utilizadas para caracterizar os modelos da análise por
elementos finitos. Os dados de deformação e resistência à fratura foram
submetidos à teste de normalidade (Shapiro-Wilk) e equivalência de variâncias
(teste de Levene), seguido por testes estatísticos paramétricos adequados para
cada tipo de ensaio. Análise de variância em fator único foi realizada para os
valores de resistência à compressão axial, deformação do remanescente e
resistência à fratura. Comparações múltiplas foram realizadas usando teste de
Tukey. Os dados de padrão de fratura foram submetidos ao teste Quiquadrado.
Análise de variância fatorial em dois fatores foi realizada
considerando como fatores em estudo: deformação da superfície do
remanescente (V e L) e a técnica de reabilitação. Todos os testes empregados
- 19 -
tiveram nível de significância α=0,05 e todas as análises foram realizadas com
o programa estatístico Sigma Plot versão 13.1 (Systat Software Ins, San Jose,
CA, USA). O uso de dois pinos de fibra de vidro resultou em menor resistência
à fratura que os grupos sem pino de fibra de vidro e com um pino de fibra de
vidro. Durante o carregamento oclusal de 100N a superfície lingual do
remanescente demonstrou maior deformação para todos os grupos. A
ausência de pino de fibra de vidro resultou em valores significativamente mais
elevados de tensões na dentina radicular e modos de fratura irreparáveis
significativamente maiores que os outros grupos. O uso de um pino de fibra de
vidro resultou em melhor razão deformação/resistência fratura. A concentração
de tensão na área de furca foi ligeiramente reduzida com uso de pino de fibra
de vidro. Conclui-se que o uso de um pino de fibra de vidro para reabilitar
molares inferiores com resina composta direta mostrou maior resistência à
fratura que o uso de dois pinos de fibra de vidro, menor deformação do
remanescente, melhor distribuição de tensões e padrão de falha com maior
número de fraturas reparáveis quando comparado a molares restaurados sem
uso de pino de fibra de vidro / Mestre em Odontologia
|
Page generated in 0.0669 seconds