• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 89
  • 4
  • Tagged with
  • 93
  • 93
  • 49
  • 40
  • 23
  • 23
  • 23
  • 20
  • 20
  • 20
  • 19
  • 18
  • 18
  • 17
  • 17
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Avaliação quantitativa da continuidade da interface cimento/dentina de cimentos resinosos com diferentes modos de polimerização empregados na cimentação de pinos de fibra de vidro

Bonfante, Estevam Augusto 24 May 2005 (has links)
Vários fatores podem influenciar a integridade da interface cimento resinoso/dentina, na cimentação de pinos intra-radiculares. A dificuldade da luz fotopolimerizadora atingir as regiões mais apicais do conduto, os estresses da contração de polimerização, a incompatibilidade entre sistemas adesivos ácidos e os cimentos autopolimerizáveis e dual, variações anatômicas da raiz, dificuldades de de controle da umidade e as características do substrato dentinário radicular são fatores limitantes. Assim, o objetivo deste estudo foi analisar quantitativamente a continuidade da interface cimento/dentina, por meio de MEV, nas seguintes condições: após a cimentação, após a imersão em solvente MEK e após 3 meses de armazenagem em água. Pinos de fibra de vidro foram cimentados em quarenta incisivos bovinos com os cimentos Multilink, Variolink II, Enforce Dual e Enforce PV. Após cimentação, os espécimes eram seccionados longitudinalmente e réplicas eram preparadas para análise em MEV. Os mesmos espécimes foram imersos em MEK e novas réplicas eram confeccionadas. Em seguida, os espécimes eram armazenados em água por 3 meses, imersos em MEK e novas réplicas eram analisadas. Quantificou-se a proporção entre a interface total cimento/dentina e a interface que apresentava continuidade com o cimento. Valores significativamente inferiores de continuidade foram observados para o Multilink (8,25%) e Variolink II (10,08%), em comparação ao Enforce Dual (25,11%) e Enforce PV (27,60%). A mesma tendência foi observada após imersão em solvente, porém sem mudanças significativas. Após 3 meses, uma significativa queda na continuidade foi observada para Multilink, Variolink II, Enforce Dual e Enforce PV (3,31%, 1,87%, 1,20%, 0,75%, respectivamente). As falhas se situaram principalmente nos terços apical e médio antes e após imersão em solvente. Após 3 meses foram detectadas falhas também no terço cervical. / Quantitative analysis of continuity between cement/dentin interface of different activation mode resin cements, when luted to fiber posts. Many factors can influence the bond integrity of posts luted into root canals. These include the difficulty of curing light to reach the most apical areas of root canals, polymerization contraction stresses, incompatibility between acidic adhesives and auto/dual-cured composites, anatomical variations of the root, problems regarding access, moisture level control and the peculiar characteristics of the root dentin substrate. Thus, it was the aim of the present investigation to perform a quantitative analysis of the continuity between resin cements and dentin interfaces, by means of scanning electron microscopic (SEM) analysis, in the following situations: after cementation, after MEK immersion, and after a 3-month water storage period. Forty bovine endodontically-treated incisors were randomly assigned to be luted with a fiber post and the following cements: Multilink, Variolink II, Enforce Dual and Enforce PV. After cementation, roots were longitudinally sectioned and replicas were prepared for SEM analysis. The same halves were immersed in MEK, replicated and evaluated. After 3 months water storage, a new set of replicas of the same halves were made and again analysed. The ratio between the total available bonding interface and the dentin interfaces that presented continuity with resin cement was then calculated. Significant lower values of continuity were found for Multilink (8,25%) and Variolink II (10,08%) when compared to Enforce Dual (25,11%) and Enforce PV (27,60%). The same trend was observed after immersion in MEK, with no significant changes. However, a significant decrease in continuity was observed after 3 month water storage for Multilink, Variolink II, Enforce Dual and Enforce PV (3,31%, 1,87%, 1,20%, 0,75%, respectively). An analysis of failure location depicted the majority of gaps at the apical and middle thirds before and after immersion in MEK. After 3 months gaps were also detected at the cervical third.
2

Avaliação quantitativa da continuidade da interface cimento/dentina de cimentos resinosos com diferentes modos de polimerização empregados na cimentação de pinos de fibra de vidro

Estevam Augusto Bonfante 24 May 2005 (has links)
Vários fatores podem influenciar a integridade da interface cimento resinoso/dentina, na cimentação de pinos intra-radiculares. A dificuldade da luz fotopolimerizadora atingir as regiões mais apicais do conduto, os estresses da contração de polimerização, a incompatibilidade entre sistemas adesivos ácidos e os cimentos autopolimerizáveis e dual, variações anatômicas da raiz, dificuldades de de controle da umidade e as características do substrato dentinário radicular são fatores limitantes. Assim, o objetivo deste estudo foi analisar quantitativamente a continuidade da interface cimento/dentina, por meio de MEV, nas seguintes condições: após a cimentação, após a imersão em solvente MEK e após 3 meses de armazenagem em água. Pinos de fibra de vidro foram cimentados em quarenta incisivos bovinos com os cimentos Multilink, Variolink II, Enforce Dual e Enforce PV. Após cimentação, os espécimes eram seccionados longitudinalmente e réplicas eram preparadas para análise em MEV. Os mesmos espécimes foram imersos em MEK e novas réplicas eram confeccionadas. Em seguida, os espécimes eram armazenados em água por 3 meses, imersos em MEK e novas réplicas eram analisadas. Quantificou-se a proporção entre a interface total cimento/dentina e a interface que apresentava continuidade com o cimento. Valores significativamente inferiores de continuidade foram observados para o Multilink (8,25%) e Variolink II (10,08%), em comparação ao Enforce Dual (25,11%) e Enforce PV (27,60%). A mesma tendência foi observada após imersão em solvente, porém sem mudanças significativas. Após 3 meses, uma significativa queda na continuidade foi observada para Multilink, Variolink II, Enforce Dual e Enforce PV (3,31%, 1,87%, 1,20%, 0,75%, respectivamente). As falhas se situaram principalmente nos terços apical e médio antes e após imersão em solvente. Após 3 meses foram detectadas falhas também no terço cervical. / Quantitative analysis of continuity between cement/dentin interface of different activation mode resin cements, when luted to fiber posts. Many factors can influence the bond integrity of posts luted into root canals. These include the difficulty of curing light to reach the most apical areas of root canals, polymerization contraction stresses, incompatibility between acidic adhesives and auto/dual-cured composites, anatomical variations of the root, problems regarding access, moisture level control and the peculiar characteristics of the root dentin substrate. Thus, it was the aim of the present investigation to perform a quantitative analysis of the continuity between resin cements and dentin interfaces, by means of scanning electron microscopic (SEM) analysis, in the following situations: after cementation, after MEK immersion, and after a 3-month water storage period. Forty bovine endodontically-treated incisors were randomly assigned to be luted with a fiber post and the following cements: Multilink, Variolink II, Enforce Dual and Enforce PV. After cementation, roots were longitudinally sectioned and replicas were prepared for SEM analysis. The same halves were immersed in MEK, replicated and evaluated. After 3 months water storage, a new set of replicas of the same halves were made and again analysed. The ratio between the total available bonding interface and the dentin interfaces that presented continuity with resin cement was then calculated. Significant lower values of continuity were found for Multilink (8,25%) and Variolink II (10,08%) when compared to Enforce Dual (25,11%) and Enforce PV (27,60%). The same trend was observed after immersion in MEK, with no significant changes. However, a significant decrease in continuity was observed after 3 month water storage for Multilink, Variolink II, Enforce Dual and Enforce PV (3,31%, 1,87%, 1,20%, 0,75%, respectively). An analysis of failure location depicted the majority of gaps at the apical and middle thirds before and after immersion in MEK. After 3 months gaps were also detected at the cervical third.
3

Estudo da interface entre pino pré-fabricado e dentina radicular por microscopia óptica e eletrônica de varredura com baixo e alto vácuo / Interfaces analysis between fiber post and root dentin using optic microscopy and SEM with low and high vaccum

Tavares, Andrea Urbano 01 June 2007 (has links)
Os objetivos deste estudo foram avaliar a adaptação das interfaces de união entre dentina radicular, cimento resinoso e pino pré-fabricado de fibra de vidro (presença ou não de fendas), variando: o método de avaliação (MEV, baixo vácuo, óptico), região da dentina radicular observando os terços apical(a), médio(m) e cervical(c) e o tratamento de superfície do pino (com ou sem silano). 20 dentes unirradiculares humanos foram tratados endodonticamente e após 72h houve a remoção da porção coronária e preparo dos condutos para receber o pino pré-fabricado FRC Postek Plus® (1.4 ? 14mm), condicionados com ácido fosfórico (37%-15s), aplicado sistema adesivo Excite DSC® e fotoativado(600mW/cm2?40s). Metade dos pinos (n=10) recebeu uma camada de silano. As amostras foram separados em grupo 1 (G1- sem silano) e grupo 2 (G2- com silano) Os pinos foram cimentados com Variolink II®, fotoativado(40s-600mW/cm2), após 72h, as raízes foram seccionadas (12 fatias-1mm), embutidas (RAAQ), polidas (#220- 4000), desidratadas, confeccionadas réplicas em resina epóxica e analisadas em microscópio óptico (MO), microscopia eletrônica de varredura (MEV) (réplicas e raizes), baixo vácuo (BV) e alto vácuo(AV). A fenda nas interfaces foi quantificada (?m) e os dados analisados (teste Aspin-Welch e t-Student), por porção (a,m,c), interface pino-cimento (pc) e cimento-dentina radicular (cd) (p<0,05). Para a análise em MO, os resultados de área aderida foram: G1 pc: am=c; G2 pc: a=m<c e cd: a=m=c. Para a análise em MEV, utilizando réplicas, G1/G2 pc e cd: a=m<c. Com relação às fendas , G1 pc e cd: a=m=c , G2 pc: a=m=c e cd: a>m=c. Para BV, G1 pc e cd: a<m=c, G2 pc: a=m<c, cd: a=m=c. Para MEV AV, G1 pc: a<m<c, cd:a=m<c e G2. pc: a=m<c, cd: a=m=c. Em todas as análises e em ambos os grupos, pc>cd. Concluindose que as informações obtidas com as diversas técnicas de microscopia se complementam, a interação pc promove maior área aderida que cd, existe diferença entre as porções da raiz e não existe diferença para o tratamento de superfície do pino. / The aim of this study was to evaluate the interface between resin cement and fiber post FRC Postek Plus® inside the root canal, using light transmission optical microscopy (MO) and Scanning electron microscope (SEM) with replica´s technique quantitative evaluation and samples analysed with high(HV) and low (LV) vaccum, considering different root region: apical (a), middle(m) and coronal (c) and the post surface treatment with or without silanization. 20 extracted human single rooted were endodontically- treated. They were decoronated and their root canals prepared to receive fiber post FRC Postek Plus® (#1-14mm). All canal were phosphoric acid etched (37%- 15s), washed, dried with paper points. Then, the Ecite DSC adhesive system was applied and light cured (600 mW/cm2?40s). The surface of 10 fiber posts were treated with silane (Monobond S). The samples were divided in two groups: G1(w/o silane) and G2(with silane). All posts were cimented with Variolink II light cured for 60s After 72h stored (distilled water ? 370C), roots were serially sliced perpendicular to the bond interface into twelve 1.0mm-thick slabs, which were divided in apical, middle and coronal root region.The samples were embeeded in acrylic resin, polished (#220-4000), dehidrated and observed at optic microscope. After that, replicas with epoxy resin were obtained. Samples and replicas were gold sputter-coated to be observed at SEM. Gap formations were quantified (?m). Results were analyzed with Aspin-Welch and t- Student´s test, considering the interface post-cement (pc), cement-dentin (cd) and the root region (c.m,a)(p<0.05). In MO, the adhesion area results were: G1 pc: am=c; G2 pc: a=m<c e cd: a=m=c. In SEM with replicas: G1/G2 pc and cd: a=m<c.Considering the gap size: G1 pc and cd: a=m=c , G2 pc: a=m=c and cd: a>m=c. To LV G1 pc and cd: a<m=c, G2 pc: a=m<c, cd: a=m=c. To SEM HV, G1 pc: a<m<c, cd:a=m<c and G2. pc: a=m<c, cd: a=m=c. To both groups and in total analysis pc>cd. So, results obtained with all the micrscopy technique add informantion among them, the interation pc has better adhesion area than cd, there is difference among the root region and no difference to the fiber post surface treatment.
4

"Estudo teórico e experimental de vigas de madeira laminada colada reforçadas com fibra de vidro" / Theoretical and experimental study of glulam beam reinforced with glass fiber

Fiorelli, Juliano 25 April 2005 (has links)
O uso de madeira laminada colada (MLC) em países da América do Norte e Europa é bastante difundido. No Brasil, apesar da técnica existir desde o século XX, a sua utilização é incipiente em relação à possibilidade de utilização desse produto. O desenvolvimento de produtos a partir de lâminas de madeira com pequenas dimensões se deve à necessidade de se eliminar defeitos nas peças estruturais, tais como nó e medula, os quais reduzem significativamente as características de resistência e elasticidade da peça, em comparação com a madeira sã. O aumento da resistência e da rigidez da viga de MLC pode ser conseguido por meio da classificação das lâminas, seguida de uma disposição adequada das mesmas. Outra maneira de se obter um aumento nas propriedades de rigidez e de resistência de elementos estruturais de MLC é a utilização de polímeros reforçados com fibras (PRF) na região mais tracionada da viga. Esta providência, além de melhorar as propriedades mecânicas do elemento estrutural, aumenta a confiabilidade em relação ao modo de ruptura. Dentro deste escopo, este trabalho procura estabelecer critérios para fabricação de vigas retas de MLC, sem e com reforço de fibras de vidro, a partir de informações obtidas na revisão bibliográfica, abordando aspectos relacionados à resistência da madeira (espécie e qualidade da madeira, quantidade de nós, inclinação das fibras em relação ao eixo longitudinal das peças, presença de medula), dimensões das lâminas, espaçamento mínimo entre emendas dentadas de uma mesma lâmina e posicionamento das emendas dentadas na viga, colagem e prensagem. Foi proposto um modelo numérico para cálculo do momento fletor resistente e da rigidez à flexão (EI) de vigas de MLC sem reforço e reforçadas com PRF. O modelo admite a validade da hipótese de distribuição linear de deformações ao longo da altura da viga, comportamento elásto-frágil-linear da madeira na tração paralela às fibras e bi-linear na compressão paralela às fibras. Este modelo foi implementado a um programa computacional que por meio de um processo interativo determina o valor do momento fletor resistente e da rigidez à flexão. Resultados experimentais obtidos por meio de ensaios em vigas de MLC reforçadas com fibra de vidro indicam a validade do modelo teórico proposto. Também foram realizados ensaios de delaminação para avaliar a eficiência dos adesivos Phenol-resorcinol e Epóxi AR-300 quando submetidos a variação de temperatura, umidade e pressão. Resultados obtidos indicaram a eficiência destes adesivos. / Glulam beam is used in countries of North America and Europe. In Brazil, the technique exists since the 20th Century, but its use is incipient in relation to the possibility of the product. The development of products that use wood with small dimensions is important to eliminate defects in the structural pieces, such as knot and marrow, which reduce the strength and stiffness of the piece. The increase of the strength and stiffness of the glulam beam can be achieved through the classification of the lumber, or by an appropriate disposition of the lumber. Another way to obtain an increase in the strength and stiffness of the glulam beam it is the use of fiber reinforced polymers (FRP). This way, besides improving the mechanical properties of the structural element, increases the reliability in relation to the rupture way. This work establish criteria for production of glulam beams, without and with reinforce of glass fiber, starting from information obtained in the bibliographical revision, approaching aspects related to the straight of the wood (species and quality of the wood, inclination of the fibers in relation to the longitudinal axis of the pieces, marrow presence), dimensions of the sheets, minimum spacing between bitten amendments of a same sheet and positioning of the jagged amendments in the beam. A numeric model for calculation of the straight moment and flexural stiffness (EI) of glulam beams was proposed. The model admits the validity of the hypothesis of lineal distribution of deformations along the height of the beam, elastic-fragile-lineal behavior of the wood in the parallel traction and bi-lineal in the parallel compression of the fibers. This model was implemented in a computer program that uses an interactive process to determine the value of the straight moment and of the flexural stiffness. Experimental results obtained indicate the validity of the theoretical model proposed. A test of delamination was done to evaluate the efficiency of the adhesives Phenol-resorcinol and Epoxy AR-300 when submitted to temperature, humidity and pressure variation. Results indicated the efficiency of these adhesives.
5

Sistema de pré-esforço de varões de GFRP para estruturas de betão

Pinheiro, Paulo Jorge Parreira January 2010 (has links)
Tese de mestrado integrado. Engenharia Civil (Especialização em Estruturas). Faculdade de Engenharia. Universidade do Porto. 2010
6

Fabrico e aplicação de towpregs de FV/PVC em tubagens

Torres, Luís Norbero Miranda January 2008 (has links)
Tese de mestrado. Manutenção Industrial. Faculdade de Engenharia. Universidade do Porto. 2008
7

Desenvolvimento de compósito de policloreto de vinila (PVC) reforçado com fibra de vidro / Development of glass fiber reinforced PVC composite

Araújo, Daniela Gomes de 06 August 2012 (has links)
Made available in DSpace on 2016-06-02T19:12:25Z (GMT). No. of bitstreams: 1 4807.pdf: 3040240 bytes, checksum: 037daf42dfeb53e1a702f669ad499014 (MD5) Previous issue date: 2012-08-06 / This work was focused on the evaluation of the interface between short fiber glass and polymeric matrix of the PVC composites using four different sizings as fiber superficial treatment. The interface analysis was done through mechanical properties study and scanning electron microscospy (SEM), while compared with unreinforced PVC compound. The PVC formulation was mixed in a mixer and, after that, 10% in weight of 4 mm fiber glass was introduced and mixed manually in the compound. The initial plan was prepare plates of the glass reinforced PVC samples through a single screw extruder to get parts for analysis, however, this process was not enough to homogenize the fibers in the PVC matrix. Due to it, a new plan was defined and the plates were milled, it was processed in a double screw extruder to obtain pallets and parts for analysis were molded through injection molding. The results attained suggested that, all superficial treatments evaluated showed satisfactory adhesion between the fiber glass and PVC matrix, besides showing an excessive fiber length reduction due to the composite processing with consequent reduction of fiber performance. / Esta dissertação de mestrado teve como objetivo avaliar a interface fibramatriz de compostos de Poli(cloreto de vinila), PVC, reforçados com fibras de vidro curtas, formuladas com quatro diferentes recobrimentos químicos. A avaliação da qualidade da interface foi feita através do estudo de evolução das propriedades mecânicas e da temperatura de termo-distorção (HDT) dos compósitos quando comparadas ao composto puro, e também, através da análise de microscopia eletrônica de varredura (MEV). O composto de PVC foi preparado em misturador intensivo e posteriormente as fibras curtas, com 4 mm de comprimento nominal, foram misturadas manualmente na formulação, apenas para que as composições pudessem ser alimentadas no funil da extrusora. Uma vez que o foco principal deste estudo é avaliar a interface fibra-matriz, em especial em avaliação por MEV, foi definida uma concentração em massa de apenas 10% de fibra de vidro, isto para uma visualização mais adequada das imagens. Inicialmente, foi planejado o uso de uma extrusora de rosca simples para incorporação, homogeneização e dispersão das fibras no composto e obtenção de placas para realização dos ensaios, porém, este processamento não foi suficiente para que as fibras se distribuíssem e dispersassem.. Assim, foi necessária uma reavaliação do plano de testes e foi definido moer as placas obtidas e realizar uma nova extrusão em uma extrusora dupla-rosca co-rotante para obtenção de compósitos granulados e posterior injeção de corpos de prova. Como principais resultados verificados, pode ser ressaltar que aparentemente todos os diferentes tratamentos químicos avaliados se mostraram satisfatórios para o desempenho dos compósitos, demonstrando interação química entre a matriz e a superfície do reforço, e também que houve quebra demasiada das fibras durante o procedimento de incorporação e moldagem por injeção, com conseqüente perda de desempenho do reforço fibroso.
8

"Estudo teórico e experimental de vigas de madeira laminada colada reforçadas com fibra de vidro" / Theoretical and experimental study of glulam beam reinforced with glass fiber

Juliano Fiorelli 25 April 2005 (has links)
O uso de madeira laminada colada (MLC) em países da América do Norte e Europa é bastante difundido. No Brasil, apesar da técnica existir desde o século XX, a sua utilização é incipiente em relação à possibilidade de utilização desse produto. O desenvolvimento de produtos a partir de lâminas de madeira com pequenas dimensões se deve à necessidade de se eliminar defeitos nas peças estruturais, tais como nó e medula, os quais reduzem significativamente as características de resistência e elasticidade da peça, em comparação com a madeira sã. O aumento da resistência e da rigidez da viga de MLC pode ser conseguido por meio da classificação das lâminas, seguida de uma disposição adequada das mesmas. Outra maneira de se obter um aumento nas propriedades de rigidez e de resistência de elementos estruturais de MLC é a utilização de polímeros reforçados com fibras (PRF) na região mais tracionada da viga. Esta providência, além de melhorar as propriedades mecânicas do elemento estrutural, aumenta a confiabilidade em relação ao modo de ruptura. Dentro deste escopo, este trabalho procura estabelecer critérios para fabricação de vigas retas de MLC, sem e com reforço de fibras de vidro, a partir de informações obtidas na revisão bibliográfica, abordando aspectos relacionados à resistência da madeira (espécie e qualidade da madeira, quantidade de nós, inclinação das fibras em relação ao eixo longitudinal das peças, presença de medula), dimensões das lâminas, espaçamento mínimo entre emendas dentadas de uma mesma lâmina e posicionamento das emendas dentadas na viga, colagem e prensagem. Foi proposto um modelo numérico para cálculo do momento fletor resistente e da rigidez à flexão (EI) de vigas de MLC sem reforço e reforçadas com PRF. O modelo admite a validade da hipótese de distribuição linear de deformações ao longo da altura da viga, comportamento elásto-frágil-linear da madeira na tração paralela às fibras e bi-linear na compressão paralela às fibras. Este modelo foi implementado a um programa computacional que por meio de um processo interativo determina o valor do momento fletor resistente e da rigidez à flexão. Resultados experimentais obtidos por meio de ensaios em vigas de MLC reforçadas com fibra de vidro indicam a validade do modelo teórico proposto. Também foram realizados ensaios de delaminação para avaliar a eficiência dos adesivos Phenol-resorcinol e Epóxi AR-300 quando submetidos a variação de temperatura, umidade e pressão. Resultados obtidos indicaram a eficiência destes adesivos. / Glulam beam is used in countries of North America and Europe. In Brazil, the technique exists since the 20th Century, but its use is incipient in relation to the possibility of the product. The development of products that use wood with small dimensions is important to eliminate defects in the structural pieces, such as knot and marrow, which reduce the strength and stiffness of the piece. The increase of the strength and stiffness of the glulam beam can be achieved through the classification of the lumber, or by an appropriate disposition of the lumber. Another way to obtain an increase in the strength and stiffness of the glulam beam it is the use of fiber reinforced polymers (FRP). This way, besides improving the mechanical properties of the structural element, increases the reliability in relation to the rupture way. This work establish criteria for production of glulam beams, without and with reinforce of glass fiber, starting from information obtained in the bibliographical revision, approaching aspects related to the straight of the wood (species and quality of the wood, inclination of the fibers in relation to the longitudinal axis of the pieces, marrow presence), dimensions of the sheets, minimum spacing between bitten amendments of a same sheet and positioning of the jagged amendments in the beam. A numeric model for calculation of the straight moment and flexural stiffness (EI) of glulam beams was proposed. The model admits the validity of the hypothesis of lineal distribution of deformations along the height of the beam, elastic-fragile-lineal behavior of the wood in the parallel traction and bi-lineal in the parallel compression of the fibers. This model was implemented in a computer program that uses an interactive process to determine the value of the straight moment and of the flexural stiffness. Experimental results obtained indicate the validity of the theoretical model proposed. A test of delamination was done to evaluate the efficiency of the adhesives Phenol-resorcinol and Epoxy AR-300 when submitted to temperature, humidity and pressure variation. Results indicated the efficiency of these adhesives.
9

Estudo da interface entre pino pré-fabricado e dentina radicular por microscopia óptica e eletrônica de varredura com baixo e alto vácuo / Interfaces analysis between fiber post and root dentin using optic microscopy and SEM with low and high vaccum

Andrea Urbano Tavares 01 June 2007 (has links)
Os objetivos deste estudo foram avaliar a adaptação das interfaces de união entre dentina radicular, cimento resinoso e pino pré-fabricado de fibra de vidro (presença ou não de fendas), variando: o método de avaliação (MEV, baixo vácuo, óptico), região da dentina radicular observando os terços apical(a), médio(m) e cervical(c) e o tratamento de superfície do pino (com ou sem silano). 20 dentes unirradiculares humanos foram tratados endodonticamente e após 72h houve a remoção da porção coronária e preparo dos condutos para receber o pino pré-fabricado FRC Postek Plus® (1.4 ? 14mm), condicionados com ácido fosfórico (37%-15s), aplicado sistema adesivo Excite DSC® e fotoativado(600mW/cm2?40s). Metade dos pinos (n=10) recebeu uma camada de silano. As amostras foram separados em grupo 1 (G1- sem silano) e grupo 2 (G2- com silano) Os pinos foram cimentados com Variolink II®, fotoativado(40s-600mW/cm2), após 72h, as raízes foram seccionadas (12 fatias-1mm), embutidas (RAAQ), polidas (#220- 4000), desidratadas, confeccionadas réplicas em resina epóxica e analisadas em microscópio óptico (MO), microscopia eletrônica de varredura (MEV) (réplicas e raizes), baixo vácuo (BV) e alto vácuo(AV). A fenda nas interfaces foi quantificada (?m) e os dados analisados (teste Aspin-Welch e t-Student), por porção (a,m,c), interface pino-cimento (pc) e cimento-dentina radicular (cd) (p<0,05). Para a análise em MO, os resultados de área aderida foram: G1 pc: am=c; G2 pc: a=m<c e cd: a=m=c. Para a análise em MEV, utilizando réplicas, G1/G2 pc e cd: a=m<c. Com relação às fendas , G1 pc e cd: a=m=c , G2 pc: a=m=c e cd: a>m=c. Para BV, G1 pc e cd: a<m=c, G2 pc: a=m<c, cd: a=m=c. Para MEV AV, G1 pc: a<m<c, cd:a=m<c e G2. pc: a=m<c, cd: a=m=c. Em todas as análises e em ambos os grupos, pc>cd. Concluindose que as informações obtidas com as diversas técnicas de microscopia se complementam, a interação pc promove maior área aderida que cd, existe diferença entre as porções da raiz e não existe diferença para o tratamento de superfície do pino. / The aim of this study was to evaluate the interface between resin cement and fiber post FRC Postek Plus® inside the root canal, using light transmission optical microscopy (MO) and Scanning electron microscope (SEM) with replica´s technique quantitative evaluation and samples analysed with high(HV) and low (LV) vaccum, considering different root region: apical (a), middle(m) and coronal (c) and the post surface treatment with or without silanization. 20 extracted human single rooted were endodontically- treated. They were decoronated and their root canals prepared to receive fiber post FRC Postek Plus® (#1-14mm). All canal were phosphoric acid etched (37%- 15s), washed, dried with paper points. Then, the Ecite DSC adhesive system was applied and light cured (600 mW/cm2?40s). The surface of 10 fiber posts were treated with silane (Monobond S). The samples were divided in two groups: G1(w/o silane) and G2(with silane). All posts were cimented with Variolink II light cured for 60s After 72h stored (distilled water ? 370C), roots were serially sliced perpendicular to the bond interface into twelve 1.0mm-thick slabs, which were divided in apical, middle and coronal root region.The samples were embeeded in acrylic resin, polished (#220-4000), dehidrated and observed at optic microscope. After that, replicas with epoxy resin were obtained. Samples and replicas were gold sputter-coated to be observed at SEM. Gap formations were quantified (?m). Results were analyzed with Aspin-Welch and t- Student´s test, considering the interface post-cement (pc), cement-dentin (cd) and the root region (c.m,a)(p<0.05). In MO, the adhesion area results were: G1 pc: am=c; G2 pc: a=m<c e cd: a=m=c. In SEM with replicas: G1/G2 pc and cd: a=m<c.Considering the gap size: G1 pc and cd: a=m=c , G2 pc: a=m=c and cd: a>m=c. To LV G1 pc and cd: a<m=c, G2 pc: a=m<c, cd: a=m=c. To SEM HV, G1 pc: a<m<c, cd:a=m<c and G2. pc: a=m<c, cd: a=m=c. To both groups and in total analysis pc>cd. So, results obtained with all the micrscopy technique add informantion among them, the interation pc has better adhesion area than cd, there is difference among the root region and no difference to the fiber post surface treatment.
10

Avaliação da resistência de união de pinos de fibra de vidro multifilamentados em canais radiculares achatados / Evaluation of the bond strength of multifilament fiberglass posts in flat-oval root canals

Assis, Rafael Souza 13 July 2018 (has links)
O objetivo do presente estudo foi avaliar a resistência de união (RU) e a interface adesiva de pinos de fibra de vidro multifilamentados e convencionais em canais radiculares achatados. Molares inferiores foram escaneados por meio de tomografia computadorizada de feixe cônico para a seleção de 22 raízes distais com canais radiculares achatados, levando em consideração a relação de diâmetro maior/menor entre 2,5 e 4,0 e de circularidade < 0,35. Foi realizado o preparo biomecânico com instrumento Reciproc R50 e obturação pela técnica de condensação lateral com cimento AH Plus. As raízes foram distribuídas em dois grupos (n=11) de acordo com o protocolo restaurador utilizado: raízes com preparo do conduto radicular e cimentação de pinos de fibra de vidro convencionais (WhitePost DC #0,5, FGM, Joinvile, SC, Brasil), e raízes sem preparo do conduto radicular e cimentação de pinos de fibra de vidro multifilamentados Comet Tail® #4 (Synca, Repentigny, Quebec, Canadá). Os pinos foram submetidos a tratamento de superfície com ácido fluorídrico 10% e cimentados com cimento RelyX U200 de acordo com as recomendações do fabricante. Após a cimentação dos pinos, os dentes foram seccionados transversalmente em slices de 1 mm de espessura, obtendo-se 2 slices de cada terço (cervical, médio e apical). Os slices mais cervicais de cada terço foram utilizados para avaliar a RU, por meio do teste de push-out com velocidade de 0,5 mm/min, e posterior análise do padrão de falha em estereomicroscópio. Os slices mais apicais de cada terço foram selecionados para análise da interface pino/cimento/dentina em microscopia eletrônica de varredura com aumentos de 100, 1000, 2000 e 4000X. Os dados de RU e adaptação da interface cimento/dentina foram submetidos aos testes de distribuição normal (Kolmogorov-Smirnov e Shapiro-Wilk) e homogeneidade (Levene). Os resultados de RU foram expressos em valores médios (e desvios-padrão) e comparados entre grupos utilizando os testes ANOVA dois fatores com pós-teste de Tukey e os resultados da adaptação da interface foram expressos em porcentagem e comparados entre grupos por meio dos testes Mann-Whitney e Kruskal-Wallis, seguido do teste de Dunns, com nível de significância de 5%. A análise de variância dois fatores evidenciou diferença estatisticamente significante para o fator tipos de pino de fibra de vidro (convencional e multifilamentado), sendo que o pino convencional (2,61 ± 1,30) apresentou os maiores valores de resistência de união quando comparado ao pino multifilamentado (1,59 ± 1,54) (P=0,008), no entanto, não houve diferença estatística para o fator terços radiculares (P=0,621) e nem para a interação dos fatores tipos de pino x terços radiculares (P=0,266). O padrão de falhas mostrou predominância de falhas adesivas mistas para os pinos convencionais e adesivas à dentina para os pinos multifilamentados. Já a análise da interface cimento/dentina por MEV, mostrou melhor adaptação do material restaurador no terço cervical para os pinos convencionais e nos terços médio e apical para os pinos multifilamentados. Conclui-se que os pinos de fibra de vidro multifilamentados apresentaram menores valores de resistência de união em relação aos pinos convencionais, com maior prevalência de falhas adesivas à dentina e melhor adaptação da interface adesiva nos terços médio e apical / The aim of this study was to evaluate the bond strength (BS) and the adhesive interface of multifilament and conventional glass fiber posts in flat-oval root canals. Mandibular molars were scanned by cone beam computed tomography for the selection of 22 distal roots with flat-oval root canals, with major / minor diameter ratio between 2.5 and 4.0 and <0.35 roundness. Biomechanical preparation with Reciproc R50 instrument and filling by lateral condensation technique with AH Plus sealer were performed. The roots were distributed in two groups (n = 11) according to the restorative protocol used: post space preparation with burs and conventional fiberglass post cementation (WhitePost DC # 0.5, FGM, Joinvile, SC, Brazil), or no post space preparation and #4 Comet Tail® multifilament fiberglass posts cementation (Synca, Repentigny, Quebec, Canada). The posts surface were treated with 10% hydrofluoric acid and cemented with RelyX U200 resin cement according to the manufacturer\'s recommendations. After the posts cementation, the teeth were sectioned transversely into 1 mm thick slices, obtaining 2 slices from each third (cervical, middle and apical). The cervical slices of each third were used to evaluate the BS by push-out test with 0.5 mm / min crosshead speed, followed by the analysis of the failure pattern by stereomicroscope. The apical slices of each third were selected for analysis of the post / resin cement / dentin interface by scanning electron microscopy with the following magnifications 100, 1000, 2000 and 4000X. The BS and adaptation of the resin cement / dentin interface data were submitted to normal distribution (Kolmogorov-Smirnov and Shapiro-Wilk) and homogeneity (Levene) tests. The BS results were expressed as mean values (and standard deviations) and compared between groups using two-way ANOVA with Tukey\'s post-test and interface adaptation results were expressed as percentages and compared between groups using the Mann-Whitney and Kruskal-Wallis, followed by Dunn\'s test, with a significance level of 5%. The two-way analysis of variance showed a statistically significant difference between the fiberglass posts types (conventional and multifilament), and the conventional posts (2.61 ± 1.30) had the highest bond strength values when compared to the multifilament (1.59 ± 1.54) (P = 0.008), however, there was no statistically significant difference for the root thirds (P = 0.621) and for the interaction between the factors (P = 0.266). The failure pattern showed a predominance of mixed adhesive failures for the conventional posts and adhesive to dentin failures for the multifilament posts. The cement / dentin interface analysis by SEM showed a better adaptation of the restorative material in the cervical third for the conventional and in the middle and apical thirds for the multifilament posts. It can be concluded that the multifilament fiberglass posts had lower bond strength values compared to conventional posts, with a higher prevalence of adhesive to dentin failures and better adhesive interface adaptation for the middle and apical thirds

Page generated in 0.0678 seconds