Spelling suggestions: "subject:"fibra dde vidro"" "subject:"fibra dde hidro""
11 |
Avaliação da microdureza de cimentos resinosos dual utilizados na cimentação de pinos de fibra de vidro submetidos a diferentes condições de polimerização e armazenamento em água / Evaluation of the microhardness of dual cure resin cements in the luting of fiberglass posts under different conditions of cure and water storageRamos, Marcelo Barbosa 29 April 2009 (has links)
Este trabalho teve como objetivo avaliar a microdureza de dois cimentos resinosos de polimerização dual (RelyX U100®, 3M-ESPE e Panavia F 2.0®, Kuraray), empregados na cimentação de pinos de fibra de vidro (Fibrekor-Jeneric® Pentron) variando o modo de polimerização em químico, fotoativação imediata ou tardia após 5min através de luz halógena, avaliando também o efeito do armazenamento em água deionizada por três meses. Este trabalho testou as seguintes hipóteses nulas: não há diferença nos valores de microdureza entre os cimentos, modo de polimerização, efeito do armazenamento e entre os terços radiculares. Sessenta raízes de incisivos bovinos, com 16mm de comprimento cérvico-apical, tiveram seus condutos obturados e, posteriormente, preparados para cimentação do pino intracanal. Os espécimes foram divididos em 6 grupos (n = 10), cada um subdividido em 2 subgrupos com 5 espécimes para cada cimento. Os pinos foram cimentados de acordo com o protocolo descrito por cada fabricante. No grupo A1, os espécimes foram mantidos em ambiente à prova de luz para que ocorresse apenas a polimerização química. No grupo B1, os espécimes foram cimentados e submetidos à fotoativação imediata, e, no grupo C1, realizou-se a fotoativação após 5 minutos. As raízes foram seccionadas longitudinalmente, para que a linha de cimento pudesse ser exposta e os testes de microdureza realizados. Após 7 dias, as médias de microdureza (± desvio padrão) foram obtidas, para os terços cervical, médio e apical, respectivamente: A1 (Panavia) - 41,25 ±3,38 / 38,17±1,74 / 35,63±1,73; A1 (U100) - 59,43±4,32 / 52,14±3,00 / 50,27±4,13; B1 (Panavia) - 75,29±4,84 / 60,36±6,76 / 48,97±3,33; B1 (U100) 62,41±6,83 / 53,99±4,74 / 49,04±2,20; C1 (Panavia) - 70,22±93 / 61,00±4,48 / 56,46±7,51; C1 (U100) - 62,40±6,66 / 53,69±2,00 / 51,54±2,18. Para os grupos armazenados em água, os valores médios de microdureza (± desvio padrão) obtidos nos 3 grupos, químico (grupo A2), fotoativado imediatamente (grupo B2) e fotoativado tardiamente (grupo C2), nos terços cervical, médio e apical, respectivamente, foram: A2 (Panavia) - 37,17±1,38 / 35,01±0,74 / 34,10±2,37; A2 (U100) - 52,39±2,00 / 52,13±3,01 / 51,06±1,48; B2 (Panavia) - 63,01±2,17 / 55,94±2,10 / 48,55±1,62; B2 (U100) - 58,81±2,34 / 55,19±1,42 / 55,71±3,17; C2 (Panavia) - 56,99±1,21 / 51,29±1,81 / 48,29±3,00; C2 (U100) - 59,02±2,04 / 57,05±2,04 / 54,95±1,05. Os resultados foram submetidos ao teste ANOVA a 4 critérios (cimento, modo de polimerização, armazenamento e terços), que detectou diferenças estatísticas entre os grupos, e o teste de Tukey foi aplicado para comparações individuais. Os resultados mostraram que: a fotoativação com luz halógena promoveu um aumento significativo nos valores de microdureza para o cimento Panavia; o armaz namento em água por três meses reduziu os valores de microdureza para a maioria dos grupos, sendo que o cimento o U100 apresentou menor variação de dureza quando comparado ao Panavia; os terços que receberam maior intensidade de luz halógena tiveram maior aumento de microdureza para ambos os cimentos, especialmente para o cimento Panavia. Conclui-se, portanto, que as hipóteses de nulidade propostas foram rejeitadas. / The objective of this study was to evaluate the microhardness of two dual cure resin cements (RelyX - U100®, 3M-ESPE and Panavia F 2.0®, Kuraray), used for fiberglass posts (Fibrekor ® - Jeneric Pentron) cementation. Chemical cure and a halogen immediate and late light cure source were compared, and the effect of storage in deionized water for three months was also evaluated. This study tested the following null hypotheses: there is no difference between the microhardness values for each dual cure resin cement, cure source type, storage time, or root thirds. Sixty bovine incisor roots 16mm long had their roots restored and then prepared for post cementation. The specimens were divided into 6 groups (n = 10), and each group was subdivided into 2 subgroups with 5 specimens for each cement. The posts were cemented according to manufacturers instructions. In group A1, the specimens were kept in a light-proof environment to ensure only a chemical cure. In group B1, the specimens were restored and subjected to immediate light curing, and in group C1, light curing was performed after 5 minutes. The roots were longitudinally sectioned to expose the cement line and perform microhardness tests. After 7 days, the average microhardness (± standard deviation) values were obtained for the cervical, medium and apical thirds, respectively: A1 (Panavia ) - 41,25±3,38 / 38,17±1,74 / 35,63±1,73; A1 (U100) - 59,43±4,32 / 52,14±3,00 / 50,27±4,13; B1 (Panavia) - 75,29±4,84 / 60,36±6,76 / 48,97±3,33; B1 (U100) - 62,41±6,83 / 53,99±4,74 / 49,04±2,20; C1 (Panavia) - 70,22±1,93 / 61,00±4,48 / 56,46±7,51; C1 (U100) - 62,40±6,66 / 53,69±2,00 / 51,54±2,18. For the 3 groups stored in deionized water (chemical [group A2], immediate light curing [group B2] and late light curing [group C2]), the average microhardness values (± standard deviation) obtained for the cervical, medium and apical thirds, respectively were: A2 (Panavia) - 37,17±1,38 / 35,01±0,74 / 34,10±2,37; A2 (U100) - 52,39±2,00 / 52,13±3,01 / 51,06±1,48; B2 (Panavia) - 63,01±2,17 / 55,94±2,10 / 48,55±1,62; B2 (U100) - 58,81±2,34 / 55,19±1,42 / 55,71±3,17; C2 (Panavia) - 56,99±1,21 / 51,29±1,81 / 48,29±3,00; C2 (U100) - 59,02±2,04 / 57,05±2,04 / 54,95±1,05. ANOVA testing was used to detect statistical differences among the 4 criteria (cements, cure mode, storage and thirds) and the Tukey test was used for individual comparisons. The results showed that the halogen light cure promoted a significant increase in microhardness values for Panavia cement; storage in water for three months reduced microhardness values for most of the groups, although U100 resulted in less microhardness variation compared to Panavia; the thirds that received a higher intensity of halogen light had a higher increase in the average values of microhardness for both cements, especially for Panavia. Therefore, the null hypotheses proposed in this work were rejected.
|
12 |
Caracterização mecânica de compósitos poliméricos bobinados em diversas orientações do reforço / Mechanical characterization of polymerics composites winding in diverse reinforced orientation of the reinforcementLeitão, Eduardo da Silva 23 March 2007 (has links)
Este trabalho tem por objetivo obter propriedades mecânicas de compósitos angle-ply fabricados pelo processo de enrolamento filamentar, na forma de placas com diversas orientações do reforço. As placas foram fabricadas com fibra de carbono e matriz epoxídica e fibra de vidro e matriz epoxídica. Os exemplares para ensaio foram obtidos nas direções de 0°, ±10°, ±20°, ±30°, ±60°, ±70°, ±80° e 90° em relação á direção do equipamento de ensaio, atribuída como sendo 0°. Resultados mostraram que para corpos-de-prova de fibra de cartaono bobinados na direção ±10° a tensão máxima média obtida foi de 855 MPa e o módulo de elasticidade médio de 136 GPa, enquanto que para corpos-de-prova de fibra de carbono bobinados na direção de ±80°, a tensão máxima média foi de 68 MPa e módulo de elasticidade médio de 10 GPa. Os resultados obtidos indicaram que as propriedades mecânicas diminuem acentuadamente a partir da direção de ±10°. Também foram obtidas as frações volumétricas, dureza Barcol e análise térmica das placas fabricadas. / This work aims to obtain some mechanical properties of angle-ply composites manufactured by the filament winding process. The plates were manufactured with different reinforcement orientation. The composites were manufactured with carbon fibers and an epoxy resin system as polymeric matrix and glass fibers and an epoxy resin system as polymeric matrix. The coupons were manufactured in the directions of 0°, ±10°, ±20°, ±30°, ±60°, ±70°, ±80° e 90°, related to the 0° fiber direction. Results show that coupons with cartDon fiber in the direction ±10°, the mean strength was 855 MPa and the mean module of elasticity was 136 GPa, whereas coupons with cartDon fiber in the direction of ±80° the mean strength was 68 MPa and the mean module of elasticity was 10 GPa. The results obtained have indicated that the mechanical strength diminishing acutely from the orientation of ±10° The volumetric fractions, Barcol hardness and thermal analysis are also obtained of all the manufactured plates.
|
13 |
Avalia??o in vitro da resist?ncia ? fratura de molares tratados endodonticamente com preparos cavit?rios MOD transfixados com um pino de fibra de vidro experimentalHenkes, Almir Jos? 31 August 2017 (has links)
Submitted by PPG Odontologia (odontologia-pg@pucrs.br) on 2018-03-09T13:27:58Z
No. of bitstreams: 1
ALMIR_JOSE_HENKES_TES.pdf: 9938064 bytes, checksum: 8470f9a982c6e56ac07eef34336431ec (MD5) / Approved for entry into archive by Tatiana Lopes (tatiana.lopes@pucrs.br) on 2018-03-13T11:52:50Z (GMT) No. of bitstreams: 1
ALMIR_JOSE_HENKES_TES.pdf: 9938064 bytes, checksum: 8470f9a982c6e56ac07eef34336431ec (MD5) / Made available in DSpace on 2018-03-13T12:00:25Z (GMT). No. of bitstreams: 1
ALMIR_JOSE_HENKES_TES.pdf: 9938064 bytes, checksum: 8470f9a982c6e56ac07eef34336431ec (MD5)
Previous issue date: 2017-08-31 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior - CAPES / This study aimed to evaluate, in vitro, through the fracture strength testing,
the influence of a fiberglass post position position, intracanal or horizontally transfixed,
inserted in endodontically treated molars with MOD preparations and restored with
composite resin and evaluate the fracture pattern after the mechanical test; and
evaluate, through the fracture strength testing, the influence of a horizontally transfixed
fiberglass post, inserted in endodontically treated molars with MOD cavity preparation
and restored with Bulk Fill resins and to evaluate the fracture pattern after the
mechanical test. In the first test, fifty extracted healthy molars were embedded in
acrylic resin and divided into 5 groups (n = 10): G1(H) - sound; G2(CP) - cavity
preparation (MOD) + endodontic treatment (E); G3 (R) - (MOD) + E + Z250 composite
resin restoration (RS); G4- (RFP) (MOD) + E + fiberglass post into root canal + RS; G5
(FT) - (MOD) + E + fiberglass post horizontally transfixed + R; In the second test, ninety
extracted molars were embedded in acrylic resin and divided into 9 groups (n = 10):
G1) Sound (H); G2)cavity preparation (MOD); G3) MOD + root canal treatment (E);
G4) E + Bulk fil composite resin (BF); G5) E + Bulk fill flow composite resin (BFF) +
Z250 composite resin (250); G6) E + Z250; G7) E + transfixed fiberglass post (TP) +
Z250 (Z250P); G8)E +TP+BF (BFP); G9) E + TP + BFF + Z250 (BFFP). The MOD
cavity preparations were standardized with 2/3 width of the vestibular-lingual distance,
with reference to the tip of the respective cusps, and occlusal-gingival depth of 4 mm,
remaining 2 mm above the cement-cementum limit. The root canal treatments were
performed in all groups, except for H group. Afterwards, the teeth were submitted to
the fracture strength testing in a universal testing machine. After the mechanical test,
the teeth were visually inspected to classify the fracture type as: pulp chamber floor
(non-recoverable) or cusps (recoverable). Means (Newtons) followed by the same
letter do not present statistical difference for ANOVA and Tukey?s test (p> 0.05): and
for the first test, group (H) 5558N A; (E) 950N C; (R) 1715N C; (FC) 1723N C; (FT)
2621N B. The predominant pattern of fracture was in cusps, and for the second test, it
was (H) 3930N a; (MOD) 957.3N d; (E) 611.2N d; (BF) 1103.3N d; (BFF) 978.3N d;
(Z250) 1359.8 d; (Z250P) 2525N b; (BFP) 1891.4N bc; (BFFP) 2031.8N bc. The
predominant failure mode was in pulp chamber floor (52.5%). The use of a horizontally
transfixed fiberglass post (FT) in the first test showed the best fracture resistance recovery compared to the (E) group. The use of a fiberglass post into root canal,
statistically, did not promote higher resistance to fracture (1723N) compared to the
group restored with composite resin only (1715N). In the second test, Inserting a
fiberglass post horizontally in molars endodontically treated and restoring with
composite resins, Bulk Fill or conventional Z250, allowed higher fracture resistance
than groups restored without post. The use of a fiberglass post decreased the
occurrence of pulpal chamber floor fractures in endodontically treated molars. / Este estudo teve por objetivo avaliar, in vitro, atrav?s do ensaio de resist?ncia
? fratura, a influ?ncia do posicionamento do pino de fibra de vidro, intracanal ou
transfixado horizontalmente, inserido em molares endodonticamente tratados com
preparos MOD e restaurados com resina composta, e avaliar o padr?o de fratura ap?s
o ensaio mec?nico; e avaliar, in vitro, atrav?s do ensaio de resist?ncia ? fratura, a
influ?ncia do pino de fibra de vidro transfixado horizontalmente, inserido em molares
endodonticamente tratados com preparos MOD e restaurados com resinas Bulk Fill,
e avaliar o padr?o de fratura ap?s o ensaio mec?nico. No primeiro ensaio, cinquenta
molares h?gidos extra?dos foram embutidos em resina acr?lica e divididos em 5 grupos
(n=10): h?gidos (H); preparo cavit?rio (MOD) + tratamento endod?ntico (E); preparo
cavit?rio (MOD) + tratamento endod?ntico + restaura??o com resina composta Z250
(R); preparo cavit?rio (MOD) + tratamento endod?ntico + pino de fibra vidro no conduto
+ restaura??o com resina composta Z250 (FC); preparo cavit?rio (MOD) + tratamento
endod?ntico pino de fibra vidro transfixado + restaura??o com resina composta Z250
(FT). No segundo ensaio, noventa molares h?gidos extra?dos foram inclu?dos em
resina acr?lica e divididos em 9 grupos (n=10): G1) H?gidos (H); G2) preparo cavit?rio
MOD (MOD); G3) (MOD) + tratamento endod?ntico (E); G4) E + restaura??o com
resina Bulk fil (BF); G5) E + Bulk fill Flow + Z250 (BFF); G6) preparo cavit?rio (MOD)
+ tratamento endod?ntico + restaura??o com resina composta Z250 (Z250); G7) E +
pino de vidro transfixado (TP) + Z250 (Z250P); G8) E+ TP + Bulk fill (BFP); G9) E+ TP
+ Bulk fill Flow + Z250 (BFFP).
Os preparos cavit?rios MOD foram padronizados com largura de 2/3 da dist?ncia
vest?bulo-lingual, tendo como refer?ncia a ponta das respectivas c?spides, e
profundidade ocluso-gengival de 4mm, permanecendo 2mm acima do limite amelocement?rio.
Foram realizados tratamentos endod?nticos em todos os grupos, exceto
para o grupo dos dentes h?gidos. Ap?s, os dentes foram submetidos ao ensaio de
resist?ncia ? fratura em uma m?quina de ensaio universal. Ap?s realiza??o dos
ensaios, os dentes foram inspecionados quanto ao tipo de fratura e classificados em:
fratura em assoalho pulpar (n?o recuper?vel) ou c?spide (recuper?vel). M?dias
seguidas de mesma letra n?o apresentam diferen?a estat?stica para ANOVA e Tukey
(p>0,05): sendo para o primeiro ensaio, grupo (H) 5558NA; (E) 950NC; (R) 1715NC; (FC) 1723NC; (FT) 2621NB. O padr?o predominante de fratura foi em c?spide, e para
o segundo ensaio, foi (H) 3930Na; (MOD) 957,3Nd; (E) 611,2Nd; (BF)1103,3Nd;
(BFF)978,3Nd;(Z250)1359,8d;(Z250P)2525Nb;(BFP)1891,4Nbc;(BFFP) 2031,8Nbc.
O padr?o de falha de fratura foi de 52,5% em assoalho da c?mara pulpar. A utiliza??o
de um pino de fibra de vidro transfixado horizontalmente (FT) no primeiro ensaio,
apresentou o melhor resultado de recupera??o da resist?ncia ? fratura comparado ao
grupo (E). A utiliza??o de um pino de fibra de vidro no conduto, estatisticamente, n?o
obteve maior resist?ncia ? fratura (1723N) comparado com o grupo restaurado
somente com resina composta, (1715N). No segundo ensaio, um pino de fibra de vidro
transfixado horizontalmente em cavidades MOD com endodontia e restaurar com
resinas compostas Bulk Fill ou convencional Z250, permitiu maiores valores de
resist?ncia ? fratura quando comparados ? n?o utiliza??o do pino. O uso do pino de
fibra de vidro diminuiu a ocorr?ncia de fraturas de assoalho da c?mara pulpar em
molares tratados endodonticamente e restaurados com resinas compostas do tipo
Bulk Fill e convencional.
|
14 |
Estudo in vitro da influência de soluções irrigantes tradicionais e soluções irrigantes e soluções alcoólicas de Azadirachta indica (Neem) na resistência de união de um cimento resinoso auto-adesivo utilizado na fixação de pinos de fibra de vidro / In vitro study of the influence of traditional irrigation solutions and alcoholic irrigating solution of Azadirachta indica (Neem) on the bond strength of a self-adhesive resin cement used for fixation of glass fiber postsSturaro, Rafael Hayaxibara 21 January 2016 (has links)
O uso de pinos de fibra de vidro são cada vez mais comuns em reabilitação oral, dessa forma vários sistemas de adesão são encontrados no mercado. Porém ainda há o desafio de manter assepsia do conduto para cimentação do pino sem contaminação. O objetivo deste trabalho foi avaliar a interação de soluções irrigantes na adesão de cimento auto-adesivo em casos de cimentação de pinos de fibra de vidro. Foram utilizados 75 caninos superiores humanos hígidos seccionados transversalmente, de modo que restaram16mm de comprimento radicular partindo do ápice. Estes dentes foram tratados endodonticamente e receberam preparo com profundidade de 12 mm. Após a inclusão das raízes em resina acrílica receberam irrigação com as soluções: G1 - Soro fisiológico; G2 - Extrato Alcoólico de Neem; G3 - EDTA 17%; G4 Hipoclorito de Sódio 2,5%; G5 - Gluconato de Clorexidina 2%. Após a cimentação dos pinos de fibra de vidro com cimento auto-adesivo estes foram submetidos a teste de tração pull out. Foram obtidos slices das raízes em corte transversal para análise em microscópio confocal a laser e microscopia eletrônica de varredura. Realizou-se teste ANOVA e Tukey para análise estatística. As seguintes médias em Newtons foram observadas: G1 - 334,0; G2 - 265,9; G3 - 281,7; G4 - 205,7; G5 - 303,1.Pela microscopia eletrônica de varredura notou-se que G4 apresentou maior degradação da dentina, G2 mostrou maior deposição de debris. Pela análise confocal observou-se prevalência de falhas adesivas. Após análise dos dados concluiu-se que o gluconato de clorexidina foi a solução que apresentou melhor força de adesão comparada às demais, além de não degradar a dentina e não deixar resíduos. Conclui-se que a Clorexidina ainda é um interessante irrigante prévio a cimentação de pinos de fibra de vidro devido às propriedades apresentadas. / The use of glass fiber posts are increasingly common in oral rehabilitation thus various adhesion systems are found on the market. But there is still the challenge of maintaining the root canal aseptic for luting post without contamination. The objective of this study was to evaluate the interaction between irrigating solutions in the selfadhesive cement in cases of luting glass fiber post. A total of 75 human maxillary canines healthy were sectioned, so that remaining 16 mm of root length from the apex. The roots were endodontic treated and post space preparation were12mm. Then, after inclusion in acrylic resin they were separated in groups according to irrigation protocol: G1 - Saline Solution; G2 - Neem Alcoholic Extract; G3 - EDTA 17%; G4 Sodium Hipocloryte 2,5%; G5 - Chlorhexidine Gel 2%. After luting of glass fiber posts with self adhesive cement these were subjected to tensile test pull out. Slices were obtained in the root cross section for analysis in confocal microscopy and scanning electron microscopy. The statistical analysis was performed by ANOVA and Tukey tests. The following averages in Newtons were observed: G1 - 334,0; G2 - 265,9; G3 - 281,7; G4 - 205,7; G5 - 303,1. By scanning electron microscopy it was noted that G4 showed higher degradation of dentin, G2 showed greater deposition of debris. By confocal analysis showed a prevalence of adhesive failures. After analyzing the data it is concluded that the G5 group showed the best bond strength compared to the others, and does not degrade the dentine and not leaving residue. It follows that the chlorhexidine is still an interesting prior irrigating cementing glass fiber post due to the properties presented.
|
15 |
Estudo das alternativas de uso da fibra de vidro sem características álcali resistente em elementos construtivos de cimento Portland / Study of alternatives to use de glass fibers without alkali-resistant characteristics in the cement composite products for civil constructionPeruzzi, Antônio de Paulo 13 December 2007 (has links)
As fibras de vidro são usadas há alguns anos com a finalidade de melhorar a resistência à tração e ao impacto de compósitos cimentícios. Mas, os álcalis do cimento Portland atacam essas fibras causando a degradação de suas propriedades mecânicas. Para contornar essa degradação, há alguns anos, foram desenvolvidas as fibras álcalis-resistente (AR) que, embora tenham apresentado melhor desempenho que as fibras de vidro convencionais, ainda apresentam perda de desempenho com o tempo. Esse trabalho trata do desenvolvimento de um novo tipo de fibra na forma de telas, a partir das fibras de vidro convencionais, usando uma impregnação de PVC como barreira para impedir o ataque químico dos álcalis do cimento. A análise da eficiência dessas telas em relação à durabilidade foi feita por meio de processo de envelhecimento acelerado e, a seguir, foram estudados os vários tipos de aplicação delas em elementos construtivos à base de matrizes cimentícias concomitantemente como o uso de barras de GFRP. Como resultado final comprovou-se a eficiência da resina desenvolvida na pesquisa para impregnação das fibras em relação à sua durabilidade frente ao meio alcalino do cimento Portland e a adequação do uso das telas impregnadas com essa resina em diversos tipos de produtos de matrizes cimentícias para construção civil. / Glass fibers are used since several years to improve the tensile and impact strengths of cement composites. But, the alkalis from Portland cement attack the glass fibers causing the deterioration of its mechanical properties. For overcome this degradation, some years ago, were developed the fibers alkali-resistant (AR) which, although presented as the best performance fiber glass conventional, still show a loss of performance over time. This work deals with the development of a new type of fiber in the form of mesh, from conventional glass staple fibers, using a PVC impregnation as barrier to hinder the chemical attack alkalis them it cement to these. The analysis of the efficiency of these fibers in relation to the durability was made by means of process accelerated ageing and, next, concomitantly studied some types of application of these fibers in constructive elements to the cements matrix with the use of bars of GFRP. The final result showed tha the resin developed in this work is efficient how coating of conventional fibers to get durability on the alkaline environment and the mesh impregnated with this resin are appropriates of the use in many kinds of products to construction made from cements matrixes.
|
16 |
Utilização de fibras de carbono e de fibras de vidro para reforço de vigas de madeira. / Exploitation of carbon fiber and glass fiber to reinforcements of timber beams.Fiorelli, Juliano 19 April 2002 (has links)
A necessidade de recuperação e reforço em estruturas de madeira, concreto e aço exigiu da construção civil uma procura por métodos mais eficientes que pudessem cumprir esse papel. Com este objetivo vários estudos estão sendo realizados utilizando fibras reforçadas com polímeros (FRP). Dentre estas fibras, as que vêm apresentando melhores resultados como reforço para peças estruturais de madeiras são as fibras de carbono e as fibras de vidro. Dentro deste escopo, este trabalho tem como objetivo estudar o comportamento estrutural de vigas de madeira de espécies nacionais reforçadas com fibras de carbono e com fibras de vidro, verificando a eficiência deste reforço e adequando modelos de cálculo para avaliação da resistência e da rigidez das vigas reforçadas, e também verificar a eficiência de uma formulação de adesivos à base de mamona e do adesivo Cascophen, para fixação das respectivas fibras na madeira, em substituição ao adesivo epóxi, normalmente utilizado. Foram efetuados ensaios de vigas de madeira reforçadas com polímeros, em modelo reduzido, e em protótipos, para diversas configurações de geometria e quantidade de fibras utilizadas. Os resultados obtidos indicam uma boa concordância entre os modelos teóricos para avaliar a resistência e a rigidez das vigas reforçadas, e os resultados experimentais, e a eficiência do reforço. Também foram conduzidos ensaios de tração em corpos-de-prova de fibras laminado com os adesivos, caracterizando a sua resistência e elasticidade e comparando o comportamento dos adesivos estudados. Os resultados indicaram o melhor comportamento do adesivo epóxi. / The necessity of rehabilitation and reinforcement in wood structures, concrete and steel demanded a search for more efficient methods that could to carry this paper. With this objectives several studies are using fibers reinforced polymers (FRP). These fibers which presenting better results in structural reinforcement for structural pieces of wood are the fibers of carbon and the glass fibers. This work has as objective studies the structural behavior of wood beams of national species reinforced with carbon fibers and with glass fibers, verifying the efficiency of this reinforcement and adapting calculation models for evaluation of the strength and stiffness of the reinforced beams, and also to verify the efficiency of a formulation of adhesives to the castor oil and of the adhesive Cascophen, for fixation of the respective fibers in the wood, in substitution the adhesive epoxy, usually used. Experimental work was made with wood beams reinforced with polymeric, in reduced model, and in prototypes, for several geometry configurations and amount of used fibers. The obtained results indicate a good agreement among the theoretical models to evaluate the strength and stiffness of the reinforced beams, and the experimental results, and the efficiency of the reinforcement. Traction rehearsals were also led in body-of-proof of fibers laminated with the adhesives, characterizing your strength and elasticity and comparing the behavior of the studied adhesives. The results indicated the best behavior of the adhesive epoxy.
|
17 |
Evidências científicas na utilização de pinos de fibra de vidro e núcleos metálicos fundidos / Scientific evidences on the use of glass fiber posts and cast metal postsMoraes, Aline Pinheiro de 07 November 2014 (has links)
Submitted by Fabiano Malheiro (fabianomalheiro22@hotmail.com) on 2017-05-18T17:43:22Z
No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Evidências científicas na utilização de pinos de fibra de vidro e nucleos metálicos fundidos.pdf: 3303685 bytes, checksum: 0b79b726661436d448f803f2526b28df (MD5) / Made available in DSpace on 2017-05-18T17:43:22Z (GMT). No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Evidências científicas na utilização de pinos de fibra de vidro e nucleos metálicos fundidos.pdf: 3303685 bytes, checksum: 0b79b726661436d448f803f2526b28df (MD5)
Previous issue date: 2014-11-07 / Sem bolsa / Tradicionalmente, os metais têm sido utilizados como retentores intrarradiculares como meio para fornecer ancoragem às restaurações devido às suas propriedades físicas adequadas e possibilidade de serem fundidos ou usinados em formas precisas. No entanto, a crescente demanda por estética tem levado ao desenvolvimento de retentores mais estéticos sendo especialmente os de fibra de vidro considerados uma alternativa aos núcleos metálicos fundidos (NMFs) na restauração de dentes tratados endodonticamente. Considerando ambos os tipos de retentores intrarradiculares, este estudo foi dividido em quatro partes. Na primeira, foi realizada uma revisão narrativa de literatura sobre os conceitos atuais na utilização de pinos de fibra de vidro. De maneira geral, concluiu-se com que o uso de pinos de fibra de vidro é uma importante opção clínica, mas deve-se tomar especial atenção às dificuldades de se obter uma boa adesão ao longo do canal radicular. Na segunda parte, foi realizada uma revisão sistemática na qual se avaliou se a utilização de silano seria benéfica para a resistência de união de pinos de fibra de vidro. Esta revisão mostrou que embora haja pouca evidência na literatura, a silanização pode melhorar a retenção de pinos de fibra de vidro quando tratamentos físicos/químicos seletivos são aplicados ao pino antes da silanização. Na terceira parte, foi realizado um estudo in vitro com o objetivo de comparar como os operadores com diferentes níveis de expertise e as técnicas de moldagem intracanal (direta ou indireta) influenciariam nas características de superfície das moldagens e qualidade dos núcleos metálicos fundidos. Os resultados mostraram que ambos os operadores e técnicas de moldagem resultaram em núcleos metálicos fundidos clinicamente aceitáveis de acordo com os padrões internacionais. No ensaio clínico randomizado foi avaliada a qualidade dos núcleos metálicos fundidos em relação a sua adaptação dependendo da posição do dente no arco e a técnica de moldagem realizada. Os resultados mostraram NMFs mais curtos quando a técnica indireta foi utilizada. No entanto, independentemente da técnica todos os pinos fundidos ficaram mais curtos do que o que foi moldado, embora clinicamente aceitáveis. A técnica indireta mostrou-se mais rápida do que a técnica direta, sendo este achado especialmente importante quando planejados casos de moldagens múltiplas e/ou espaço interoclusal reduzido. Desta forma, podemos concluir que os dados do estudo in vitro corroboram com os dados do ECR, uma vez que independentemente da técnica de moldagem, dos operadores e da posição do dente no arco, todos os núcleos metálicos fundidos foram mais curtos do que o que foi moldado, embora clinicamente aceitáveis. / Traditionally, metals have been used to fabricate dental posts because of their suitable physical properties and possibility of being cast or machined into precise shapes. However, in recent decades, the increasing demand for aesthetics has led to the development of glass fiber posts. Glass fiber posts are considered an alternative to cast metal posts to restore endodontically treated teeth. Considering both types of intracanal posts, this study was divided into four parts. In the first, a narrative literature review of current concepts in the use of glass fiber posts was performed. In general, it may be said that the use of fiber posts is an important clinical option in Dentistry, but clinicians should be aware of the difficulties in achieving good adhesion within the root canal. In the second part, a systematic review evaluated if the use of silane would be beneficial to the bond strength of glass fiber posts. This review showed that although there is little evidence in the literature, silanization might improve the retention of glass fiber posts luted into root canals provided that selective physical/chemical surface treatments are applied to the post before silanization. In the third part, an in vitro study compared how operators (experienced or not) and intracanal impression techniques (direct or indirect) influenced the surface characteristics of the impressions and the quality of cast metal posts. Results showed that both operators and techniques resulted in clinically acceptable posts according to international standards. The fourth part of this study evaluated the accuracy of cast metal posts depending on the tooth position and impression technique performed on a randomised controlled trial. Results showed that cast metal post were shorter than their respectvive impressions for all variables tested, but resulted in clinically acceptable metal posts. However, the direct technique was more time-consuming than the indirect technique, which is especially important in cases of multiple teeth involved and/or reduced interarch space. Thus, it may be concluded that data from the in vitro study corroborated with the RCT, as irrespective of the impression technique, operator level of expertise or the position of the tooth in the arch all cast metal posts were shorter, but clinically acceptable.
|
18 |
Failure analysis of GRP pipes under compressive ring loadsFaria, Hugo Queirós de January 2005 (has links)
Tese de mestrado. Faculdade de Engenharia. Universidade do Porto. 1998
|
19 |
Estudo da tolerância ao dano de tubagens em PRFVCorreia, Sónia Marisa Maciel Leitão January 2008 (has links)
Tese de mestrado. Engenharia Mecânica. Faculdade de Engenharia. Universidade do Porto. 2008
|
20 |
Avalia??o de concretos refor?ados por confinamento com manta de fibra de vidro estrutural e pr?-impreganadaPereira, F?bio S?rgio da Costa 30 November 2009 (has links)
Made available in DSpace on 2014-12-17T14:07:02Z (GMT). No. of bitstreams: 1
FabioSCPpdf.pdf: 1533458 bytes, checksum: 0df903e6bea6c66d762b8b1bbe3c6937 (MD5)
Previous issue date: 2009-11-30 / Due to the occurrence of diseases in the use of structural reinforcements in composites, with presentation of concrete blanket detachment, has been identified the need to evaluate the performance of concrete reinforced with glass fiber. This study aims to evaluate these concretes by means of testing methodologies, using concrete with low resistance with structural reinforcement for confinement by preimpregnated glass fiber and traditional fiberglass blanket. The first stage of work was the development of methodologies for analysis, opting for four types, such as the acoustic survey, strength to compressive, the pull-off and ultrasound. Next, tests were carried out using the four selected methodologies in 30 of proof-of-specimens by 5x10 cm, 15 were reinforced with the traditional fiberglass blanket with 5specimens exposed to test a marine environment of marine coastline of Natal-RN and 15 were reinforced with a pre-impregnated glass fiber blanket, as well as 5specimens exposed to a test environment of the marine coastline of Natal-RN. After conducting the acoustic survey, it has been verified a lack of delaminating and air bubbles in the samples, confirming the absence of gross shortcomings in the implementation of the ribs both the traditional fiberglass blanket and in the preimpregnated fiber glass blanket. After carrying out methods of pull-off and compressive strengthening test it was observed that the reinforced proof-bodies with pre-impregnated glass blanket showed maximum stresses higher than the traditional fiberglass blanket; consequently a greater grip with the formation of a smaller area of . fracture, unlike traditional glass mat, which showed lower maximum stresses, with a greater area of fracture. It was also found that the traditional fiberglass blanket presented detachment of blanket-concrete interface, unlike the pre-impregnated fiberglass blanket, which showed a better grip on the blanket-concrete interface. In the trial of ultrasound there was no presence of cracks in the blanket-concrete interface, yielding to both blankets good compactness of the concrete. At the end of this work, they were developed and proposed two methods of testing for evaluation of reinforced concrete structures with composites, for standardization, the acoustic survey and pull-off / Em virtude da ocorr?ncia de patologias na utiliza??o de refor?os estruturais com comp?sitos, com apresenta??o de descolamento da manta do concreto, foi identificada a necessidade de se avaliar o desempenho dos concretos refor?ados com a fibra de vidro. Sendo o objetivo principal deste trabalho, avaliar estes concretos, atrav?s de metodologias de ensaios, utilizando concretos com resist?ncias baixas com refor?o estrutural por confinamento por fibra de vidro pr?impregnada e por manta de fibra de vidro tradicional. A primeira etapa do trabalho consistiu na elabora??o das metodologias de an?lise, optando-se por quatro tipos, a sondagem ac?stica, resist?ncia ? compress?o,o pull-off e o ultra-som. Em seguida, foram realizados os ensaios utilizando as quatro metodologias escolhidas em 30 corpos-de-prova de 5x10 cm, sendo 15 refor?ados com a manta de fibra de vidro tradicional, com 5 corpos-de-prova expostos a um ambiente marinho da orla mar?tima de Natal-RN e sendo 15 refor?ados com a manta de fibra de vidro pr?impregnada, tamb?m com 5 corpos-de-prova expostos a um ambiente marinho da orla mar?tima de Natal-RN. Ap?s a realiza??o dos ensaios de sondagem ac?stica, verificou-se a inexist?ncia de delamina??es e bolhas de ar nas amostras analisadas, comprovando a inexist?ncia de falhas grosseiras na aplica??o dos refor?os tanto na manta de fibra de vidro tradicional, como na da manta de fibra de vidro pr?impregnada. Depois de executadas as metodologias de ensaios de resist?ncia ? compress?o e pull-off, observou-se que os corpos-de-prova refor?ados com a manta de vidro pr?-impregnada apresentaram tens?es m?ximas superiores ?s obtidas com a manta de fibra de vidro tradicional, consequentemente uma ader?ncia maior, com a forma??o de uma menor ?rea de fratura, ao contr?rio da manta de vi dro tradicional, que apresentou tens?es m?ximas inferiores, com uma maior ?rea de fratura. Verificou-se ainda que a manta de fibra de vidro tradicional apresentou descolamento da interface manta/concreto, ao contr?rio da manta de fibra de vidro pr?-impregnada, que apresentou uma maior ader?ncia na interface manta/concreto. No ensaio de ultra-som n?o se observou presen?a de fissuras na interface manta/concreto, obtendo-se para ambas as mantas, boas compacidades do concreto. Ao final do trabalho foram elaboradas e propostas duas metodologias de ensaios para avalia??o das estruturas de concreto armado refor?adas com comp?sitos, para normaliza??o, a sondagem ac?stica e o pull-off
|
Page generated in 0.0665 seconds