Spelling suggestions: "subject:"fibra dde vidro"" "subject:"fibra dde hidro""
51 |
Influência do cimento resinoso e do cimento endodôntico sobre a resistência e durabilidade da união entre um pino de fibra de vidro e a dentina intra radicular: avaliação in vitroLanda, Fabiano Vieira de 01 March 2013 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2016-05-13T13:13:15Z
No. of bitstreams: 1
fabianovieiradelanda.pdf: 991924 bytes, checksum: 76f33860854c1fc8809b33683cbef6a6 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2016-06-27T20:33:37Z (GMT) No. of bitstreams: 1
fabianovieiradelanda.pdf: 991924 bytes, checksum: 76f33860854c1fc8809b33683cbef6a6 (MD5) / Made available in DSpace on 2016-06-27T20:33:37Z (GMT). No. of bitstreams: 1
fabianovieiradelanda.pdf: 991924 bytes, checksum: 76f33860854c1fc8809b33683cbef6a6 (MD5)
Previous issue date: 2013-03-01 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O objetivo do presente estudo foi avaliar as seguintes hipóteses: Ho- não haveria influência do cimento resinoso e do cimento obturador do canal radicular sobre a durabilidade da união entre um pino de fibra de vidro e a dentina intra-radicular; H1- haveria a influência do tipo do cimento obturador sobre a durabilidade de união entre um pino de fibra de vidro e a dentina intra-radicular: H2-haveria a influência do tipo de cimento resinoso sobre a durabilidade de união entre um pino de fibra de vidro e a dentina intra-radicular e H3-haveria a influência da profundidade da cimentação sobre a durabilidade de união entre um pino de fibra de vidro e a dentina intra-radicular.
Foram utilizados 40 caninos humanos, os quais foram divididos aleatoriamente em quatro grupos.R+E Relyx U100/ Endofill, P+E Panavia F2.0/EndoFill, R+S Relyx U100/Sealer 26, P+S Panavia F2.0/Sealer 26. Ao término dos procedimentos de cimentação, os corpos de prova foram seccionados em uma máquina de corte de precisão (Lab Cut Isomet 1000 Precision Saw) em 4 fatias de 2mm referente as diferentes profundidades: Apical, Médio Apical, Médio Coronal, Coronal. Em seguida, as fatias foram submetidas a ensaios mecânicos de extrusão Push-out em uma máquina de ensaios mecânicos EMICcom célula de carga de 50N, a velocidade de 0,5mm/min.Os resultados obtidos de acordo com as diferentes profundidades de cimentação analisados foram os seguintes(p≥0,05) (Mpa),1 porção apical R+E (1,35±1,28), P+E (2,70±0,89), R+S (3,89±0,70), P+S (4,30±1,02), 2 porção médio apical R+E (1,38±1,28), P+E (2,98±1,43), R+S (4,02±1,14), P+S (4,49±1,82), 3 porção médio coronal R+E (2,46±0,73), P+E (3,72±0,78), R+S (4,85±0,71), P+S (6,14±0,73), 4 porção coronal R+E (5,59±1,08), P+E (5,74±1,06),
R+S(6,71±1,07), P+S (7,40±1,51).Os resultados obtidos confirmam as três hipóteses testadas: h1,h2 e h3. / This work has sought to evaluatethe following hypothesis: Ho-there would be no influence ofresin cementandroot canalsealeron the durabilityof the union betweenthe fiberglass postand the dentin, H1- would influencethetypesealeron the durabilityof the union between thefiber glass post andthedentin: H2-wouldinfluencethe type ofresin cementon the durabilityof the union betweenthe fiber glass post andthedentinandH3-would influencethe depth ofcementationon the durabilityof the union between the fiber glass post andthe dentin.
Fortyhuman canines, were randomly dividedinto four groups. G1(R +E)RelyxU100/Endofill, G2(P +E)PanaviaF2.0/EndoFill, G3(R +S) RelyxU100/Sealer26,G4(P +S) PanaviaF2.0/Sealer26.At the endof thecementingprocedure, the specimenswere sectionedin aprecisioncutting machine(Isomet 1000PrecisionLabCutSaw) on 4slices of2mm. Thenthe sliceswere subjected tomechanical testsextrusionPush-out in amechanical testing machinewith a load cellEMIC50N, speed 0.5 mm/ min.The resultsaccording to different depthcementinganalyzedwere as follows: (p ≥ 0.05) (Mpa) 1apical R+E (1.35 ±1.28), P+E (2.70 ±0.89),R+S(3.89±0.70), P+S(4.30±1.02), 2 middleapicalR+E(1.38±1.28), P+E(2.98±1.43), R+S(4.02± 1.14), P+S(4.49±1.82), 3 mediumcoronalR+E(2.46±0.73), P+E(3.72±0.78), R+S(4,85 ±0.71), P+S(6.14±0.73), 4 coronalR+E(5.59±1.08), P+E(5.74±1.06), R+S(6.71±1.07), P+S (7.40 ±1.51). The results also confirmedthe threehypothesis tested: h1, h2andh3.
|
52 |
[pt] COMPORTAMENTO MECÂNICO DE COMPÓSITOS CIMENTÍCIOS REFORÇADOS COM TECIDO DE FIBRAS DE VIDRO E SISAL: ASPECTOS ESTRUTURAIS E DURABILIDADE / [en] MECHANICAL BEHAVIOR OF CEMENT BASED COMPOSITES REINFORCED WITH GLASS AND SISAL FABRIC: STRUCTURAL ASPECTS AND DURABILITYRENNAN LIBERATO RODRIGUES 09 June 2022 (has links)
[pt] A necessidade de estruturas mais leves e esbeltas tem motivado a pesquisa
por materiais alternativos, o que levou, nas últimas décadas, ao concreto têxtil
(TRC) ou argamassa de cimento reforçada com tecido (FRCM). Além da leveza e
finura, vale ressaltar a alta ductilidade deste tipo de compósito. No entanto, ainda
são poucos os estudos sobre o comportamento mecânico desse material,
principalmente quando submetido a situações de alta agressividade ambiental.
Portanto, o objetivo deste estudo é analisar o comportamento mecânico de
compósitos cimentícios reforçados com fibras naturais e tecido de fibra sintética.
Para isso, foram desenvolvidos compósitos em formato de placas e vigas de seção
I fabricados com dois tipos de matrizes, que variavam quanto ao teor de hidróxido
de cálcio, reforçados com diferentes porcentagens de tecido de fibra de vidro álcali
resistente e de fibra de sisal. As amostras foram submetidas a ensaios de tração
direta e flexão a quatro pontos tanto em condições normais quanto após
envelhecimento acelerado em câmara de névoa salina. Concluiu-se que, embora os
elementos reforçados com tecido de fibra de vidro apresentem um desempenho
satisfatório em condições normais de ensaio, quando colocados em ambientes
salinos há uma degradação considerável tanto da fibra quanto da interface entre o
tecido e a matriz, prejudicando a performance do compósito. Observou-se também
que a matriz com baixo teor de hidróxido de cálcio auxiliou na preservação da
capacidade resistente dos tecidos utilizados no estudo, com destaque para o
desempenho compósito reforçado com fibra de vidro ensaiado em condições
normais e o reforçado com fibra de sisal nas duas condições de ensaio propostas. / [en] The need for lighter and slender structures has led civil engineers to look for
alternative materials, which has led, in recent decades, to cementitious composites
reinforced with fabrics. This new type of material is known as textile reinforced
concrete (TRC) or Fabric Reinforced Cement Mortar (FRCM). In addition to the
lightness and slimness, it is worth mentioning the high ductility of the material.
Nevertheless, there are still only a few studies on durability and mechanical
mechanisms when it occurs in situations with high environmental aggressiveness,
such as coastal areas. Therefore, the objective of this study is to analyze the
influence of saline environments on cementitious composites reinforced with
natural sisal and alkali resistant glass fabrics. Two types of matrices were
developed: one with a high calcium hydroxide content, only with Portland cement
and the other with a lower content, due to the partial replacement of Portland cement
by Metacaulim and fly ash. The TRC specimens were placed for accelerated aging
in a salt steam walk-in chamber with a concentration of 3.5 percent NaCl and 70 degree Celsius . After
1000 hours of aging, the specimens were removed from the chamber and subjected
to direct tensile tests. The degradation mechanisms were discussed and a
comparison between the mechanical behavior of the two composite systems were
addressed.
|
53 |
Estudo do efeito da radiação ionizante sobre as propriedades da poliamida 6 com reforço de fibra de vidro / Study of the effect of ionizing radiation on properties of polyamide 6 with fibreglass reinforcementPinto, Clovis 25 May 2007 (has links)
É cada vez maior a utilização de polímeros reforçados com fibra de vidro no mercado nacional. Entre eles utiliza-se a poliamida 6 que apresenta ótima resistência à tração, ao impacto e à absorção de umidade comparada à poliamida 6 sem reforço de fibra de vidro, sendo atualmente utilizada na indústria automobilística em peças sob o capô, em especial em carcaças de radiadores. Este trabalho foi realizado com o objetivo de estudar o efeito da radiação ionizante nas propriedades mecânicas (resistência à tração, à flexão e ao impacto Izod) e térmicas (resistência ao fio incandescente e temperatura de fusão) da poliamida 6 com reforço de fibra de vidro, submetida à diferentes doses de radiação (100 a 600 kGy). As amostras foram preparadas e irradiadas em um acelerador JOB 188 com feixe de elétrons de energia de 1,5 MeV em diferentes doses e uma taxa de dose de 22,61 kGy/h. Após a irradiação, as propriedades das amostras da poliamida 6 com reforço de fibra de vidro irradiada foram determinadas e comparadas com as amostras não irradiadas e constatou-se que as propriedades mecânicas de resistência à flexão e à tração aumentaram e a de resistência ao impacto diminuiu. Em relação à propriedade térmica de temperatura de fusão diminuiu de 224,4ºC para 212,5ºC mas a perda de massa diante do aumento constante da temperatura também diminuiu. Em relação à propriedade de resistência ao fio incandescente a poliamida 6 com reforço de fibra de vidro irradiada teve um bom desempenho. As imagens captadas por Microscopia Eletrônica de Varredura mostram que a irradiação provocou uma boa integração entre a fibra de vidro e o polímero o que foi responsável pelo bom desempenho na propriedade de resistência ao fio incandescente. / It is each time more common the use of polymers reinforced with fibreglass in the domestic market. Between them it is used polyamide 6 that it presents good tension resistance, to the impact and the humidity absorption compared with non-reinforced, being also at the present time used in the automobile industry in parts underneath the hood, especially in the radiator frames. The aim of this work is to study the effect of ionizing radiation on properties of polyamide 6 with fibreglass reinforcement, undergone to different radiation doses. Samples were prepared and irradiated on JOB 188 accelerator with an electron beam energy of 1.5 MeV in air with different doses (100 to 600 kGy) and a dose rate of 22.61 kGy/h. Afterward the irradiation, the properties of the samples of irradiated polyamide 6 with fibreglass reinforcement were evaluated and compared with the samples non-irradiated. It evidenced that the mechanical properties flexural resistance and tension resistance increased and the resistance to the impact decreased. Regarding the thermal properties of the temperature of fusing decreased of 224,4ºC for 212,5ºC but the loss of mass ahead of the constant increase of the temperature also decreased. In the property of resistance to the glow wire the polyamide 6 with fibreglass reinforcement had a good performance. The images caught for Scanning Electronic Microscopy show that the irradiation provoked a good integration enters the fibreglass and polymer what was responsible for the good performance in the property of resistance to the glow wire.
|
54 |
Avaliação da espessura de cimento e resistência adesiva de pinos de fibra de vidro cônicos em preparo para retentor intra-radicular realizados com uma ponta ultrassônica desenvolvida / Assessment of cement thickness and bond strength of circular fiber posts in post space preparations with an ultrasonic tip developedCardenas, José Edgar Valdivia 30 October 2017 (has links)
Preparos para retentores intra-radiculares mais conservadores evitam desgaste desnecessário da estrutura dentinária, requer menos cimento e podem melhorar a retenção adesiva do pino. Assim o objetivo deste estudo foi avaliar a espessura de cimento ea resistência adesiva de pinos de fibra de vidro cônicos em preparo para retentor intra-radicular realizados com uma ponta ultrassônica desenvolvida. Trinta incisivos laterais superiores foram preparados com limas reciprocantes Wave One Gold (Dentsply Sirona, Ballaigues, Suiça) e aleatoriamente divididos em 2 grupos (n=15) de acordo com a técnica de preparo para pino: grupo US foram preparados com uma ponta ultrassônica desenvolvida, e grupo WP (controle) com a broca recomendada pelo fabricante do pino. Os pinos de fibra de vidro cônicos WhitePost DC 0.5 (FGM, Joinville, SC, Brasil) foram cimentados utilizando cimento resinoso dual nos terços cervical e médio do canal radicular. Isto posto, todos os espécimes foram seccionados transversalmente em três seções (cervical, média e apical do pino) para análise da área de cimento resinoso ao redor do pino que foi calculada através do programa AutoCAD, em seguida, para avaliar a resistência adesiva, o teste de cisalhamento por extrusão foi aplicado através de uma maquina de ensaio universal numa velocidade média de 0.5 mm/min até o deslocamento do conjunto restaurador intra-radicular e o tipo de falha avaliado por estereomicroscopia. A comparação entre grupos e entre terços da área de cimento e resistência adesiva foram analisadas pelo teste t independente e Anova com Tukey; e os tipos de falha entre os grupos por Mann-Whitney, todos com nível de significância de 5%. No grupo ultrassônico foi observado a menor quantidade de cimento (p<0.05) e a resistência adesiva nos diferentes grupos e terços se manifestou maior somente no terço apical do grupo ultrassônico (p<0.05). Falha adesiva entre cimento e dentina foi a mais prevalente do terço cervical e apical do grupo US e cervical de grupo WP. Falha adesiva entre cimento e pino foi a mais prevalente nos demais terços. Conclui-se que o preparo para retentor com a ponta ultrassônica desenvolvida requer menor quantidade de cimento e influencia na melhor resistência de união no terço apical do pino de fibra de vidro. / Conservative post space preparations for intra-radicular retainers prevent unnecessary desgaste of the dentin structure, require less cement and improve bond strength of the post. The aim of this study was to evaluate the influence of resin cement thickness and bond strength of prefabricated glass fiber circular postin post space preparations with an ultrasonic tip developed. Thirtymaxillarylateral incisors were prepared with Wave One Gold reciprocating files (Dentsply Sirona, Ballaigues, Switzerland) and randomly divided into 2 groups (n=15) according to the post preparation technique: gruoup US was prepared with an ultrasonic tip developed and group WP (control) with the drill recommended by the post fabricant. Every glass fiber posts WhitePost DC 0.5 (FGM, Joinville, SC, Brazil) was cemented using dual polymerizing resin cement in the cervical and middle thirdof the root canal. After that, every specimen was sectioned transversally into three sections(cervical, middle and apical of the post) and the resin cement thickness area was calculated with AutoCAD program, the bond strength test was done with an universal testing machineat medium velocity 0.5 mm/min and the failure pattern after the test was analyzed with stereomicroscopy. Datas obtained were analyzed statistically using Student\'s t-Test, ANOVA,andTukey\'s test. The comparison of failure modes between the groups in the different thirds was done using Mann-Whitney test, All of those at a 5% significance. Ultrasonic group presented thinnest layer of cement in all thirds (p<0,05), which also obtained a higher bond strength only in apical third (p<0,05). Adhesive failurebetween cement and dentinwas the most prevalent of the cervical and apical third of G1 and cervical of G2.Adhesive failure between cement and post was the most prevalent in the others thirds. It can be concluded that the postpreparation with the ultrasonic tip developed provides a smaller thickness of resin cement that influenced thebond strength in the apical third of the glass fiber post.
|
55 |
Efeito da adição de fibras de vidro particuladas nas propriedades mecânicas de resinas acrílicas utilizadas para a confecção de placas oclusais / Effect of addition of the particulate glass fibers in mechanical properties of acrylic resins used for the making occlusal splintsSoares, Rodrigo Gonçalves 06 July 2010 (has links)
Placas oclusais são dispositivos intraorais utilizados no manejo de pacientes que apresentam desordens do sono, migrânia do tipo tensional e outros. No entanto são os cirurgiões dentistas que predominantemente utilizam as placas oclusais como tratamento do equilíbrio das arcadas dentárias nas disfunções temporomandibulares, prevenção de desgaste dental em pacientes com hábitos parafuncionais e na prevenção de traumas em atletas. Vários métodos têm sido empregados para reforçar resinas acrílicas, como reforço metálico e atualmente a incorporação de diferentes tipos de fibras tais como: carbono, polietileno e vidro. Contudo a adição de fibras de vidro com partículas menores em algumas propriedades mecânicas ainda permanecem desconhecidas. Objetivo: O objetivo desse estudo foi avaliar algumas propriedades mecânicas como a rugosidade de superfície, microdureza, módulo de elasticidade e resistência flexural em resinas acrílicas após a incorporação de fibras de vidro particuladas pré silanizadas. Material e método: Para avaliação das propriedades foram confeccionados vinte e quatro corpos de prova (65 x 10 x 3 mm) de cada marca comercial de resina acrílica, utilizadas para confecção de placas oclusais, Vipi Flash (autopolimerizável), Vipi Wave (termopolimerizável por calor de microondas), Vipi Crill, Lucitone e QC-20 (termopolimerizáveis por calor de banho de água), sendo doze corpos-de-prova controles, e doze experimentais, com adição de 10% em peso de fibras de vidro particuladas (Reforplás S/A, São Paulo, SP, Brasil). Após a realização do acabamento superficial dos corpos de prova com lixas de carborundum e feltros era realizada a avaliação da rugosidade superficial em rugosímetro (Mitutoyo®) com três leituras ao longo dos corpos-de-prova, a microdureza Vickers era analisada em um microdurômetro (Micro Hardness Tester, Shimadzu, Japan) com cinco mensurações em cada corpo-de-prova, e para avaliar os ensaios de resistência flexural e módulo de elasticidade os corpos-de-prova foram avaliados por meio uma máquina de ensaios universal (Emic DL 2000®, Emic, São José dos Pinhais, PR, Brasil), com velocidade de 5mm/min. Os dados foram analisados estatisticamente, usando testes paramétricos e não paramétricos, de acordo com a distribuição da amostra. Resultados: As médias e desvios padrões do teste de rugosidade superficial em Ra foram Vipi Flash sem fibra (0,10 ± 0,03); Vipi Flash com fibra (0,12 ± 0,01); Vipi Wave sem fibra (0,16 ± 0,02); Vipi Wave com fibra (0,13 ± 0,02); Vipi Cril sem fibra (0,12 ± 0,03); Vipi Crill com fibra (0,15 ± 0,03); Lucitone sem fibra (0,10 ± 0,02); Lucitone com fibra (0,09 ± 0,04); QC-20 sem fibra (0,11 ± 0,02) e QC-20 com fibra (0,18 ± 0,03). As médias e desvios-padrão ao teste de microdureza Knoop com relação às marcas comerciais foram: Vipi Flash sem fibra (15,35 ± 0,3); Vipi Flash com fibra (15,51 ± 0,4); Vipi Wave sem fibra (16,60 ± 0,8); Vipi Wave com fibra (17,25 ± 0,9); Vipi Cril sem fibra (17,78 ± 2,27); Vipi Crill com fibra (18,02 ± 1,0); Lucitone sem fibra (15,72 ± 0,3); Lucitone com fibra (16,69 ± 0,6); QC-20 sem fibra (15,91 ± 0,4) e QC-20 com fibra (15,63 ± 0,2). As médias e desvios-padrão ao teste de módulo de elasticidade foram: Vipi Flash sem fibra (2952,76 ± 292,12); Vipi Flash com fibra (3373,49 ± 403,76); Vipi Wave sem fibra (2511,69 ± 304,09); Vipi Wave com fibra (3225,01 ± 248,66); Vipi Cril sem fibra (2745,61± 288,86); Vipi Crill com fibra (3671,67 ± 329,91); Lucitone sem fibra (1904,53 ± 149,05); Lucitone com fibra (3056,87 ± 126,11); QC-20 sem fibra (1913,86 ± 147,80) e QC-20 com fibra (2858,32 ± 185,26). As médias e desvios-padrão ao teste de resistência flexural foram Vipi Flash sem fibra (81,62 ± 4,82); Vipi Flash com fibra (83,98 ± 4,98); Vipi Wave sem fibra (83,52 ± 8,79); Vipi Wave com fibra (88,98± 8,47); Vipi Cril sem fibra (64,17± 5,46); Vipi Crill com fibra (93,37 ± 9,97); Lucitone sem fibra (74,71± 9,43); Lucitone com fibra (87,29 ± 4,73); QC-20 sem fibra (75,80 ± 8,82) e QC-20 com fibra (81,67± 12,97). Conclusão: Conclui-se que a incorporação de fibras provocou alterações em praticamente todas as propriedades analisadas, sendo, portanto facilmente utilizável como um reforço adicional às resinas acrílicas. Com relação à dureza superficial as resinas acrílicas termopolimerizável por banho de água e termopolimerizável por calor de microondas apresentaram maiores valores quando comparados com a resina acrílica autopolimerizável. Além disso, a adição de fibras de vidro particuladas aumentou os valores de rugosidade de algumas resinas acrílicas Vipi Crill, Vipi Flash e Vipi Wave e se manteve constante nas resinas Lucitone e QC-20. A adição de fibra de vidro não aumentou significantemente a microdureza Knoop nos grupos em estudo. Com relação à resistência flexural as fibras de vidro particuladas aumentaram significantemente todos os valores, assim como o módulo de elasticidade das resinas acrílicas reforçadas pela adição de fibras de vidro. / Intraoral Occlusal splints are devices used in the management of patients with sleep disorders, migraine type tension and others. But dentists who are predominantly using the plates as a treatment of occlusal balance of the dental arches in temporomandibular disorders, prevention of tooth wear in patients with habits and prevention of injuries in athletes. Several methods have been used to strengthen acrylic resins, such as metal reinforcement and are currently incorporating different types of fibers such as carbon, polyethylene and glass. However the addition of glass fibers with smaller particles on mechanical properties are still unknown. Objective: The objective of this study was to evaluate some mechanical properties such as surface roughness, hardness, elastic modulus and flexural strength in acrylic resins after the incorporation of glass fiber particulate pre silanized. Methods: To evaluate the properties were made twenty-four specimens (65 x 10 x 3 mm) of each brand of acrylic resin, used for fabrication of occlusal splints, Vipi Flash (self-curing), Vipi Wave (by thermo microwave heat), Vipi CRILL, Lucitone and QC-20 (thermo heat water bath), with twelve specimes controls, and twelve experimental, with the addition of 10 wt% glass fiber particulate (Reforplás S / A, São Paulo, Brazil). After completion of the roughness of the specimens with grit carborundum and felt it was evaluated the surface roughness on roughness tester (Mitutoyo ®) with three readings over the specimes, the microhardness was examined with a hardness ( Micro Hardness Tester, Shimadzu, Japan) with five measurements in each specime, and evaluate the tests for flexural strength and modulus of elasticity of the specimes was evaluated using a universal testing machine (Emic DL 2000 ®, Emic, São José dos Pinhais, PR, Brazil), with speed 5mm/min. The data were statistically analyzed using parametric and nonparametric tests, according to the sample distribution. Results: The mean and standard deviation of the test surface roughness were Vipi Flash without fiber (0.10 ± 0.03); Flash Vipi with fiber (0.12 ± 0.01); Vipi Wave without fiber (0, 16 ± 0.02); Vipi Wave with fiber (0.13 ± 0.02); Vipi Cril without fiber (0.12 ± 0.03); Vipi CRILL with fiber (0.15 ± 0.03); Lucitone without fiber (0.10 ± 0.02); Lucitone with fiber (0.09 ± 0.04), QC-20 fiber without (0.11 ± 0.02) and QC-20 with fiber (0.18 ± 0.03). Means and standard deviations for Knoop microhardness test with respect to trademarks were Vipi Flash without fiber (15.35 ± 0.3); Flash Vipi with fiber (15.51 ± 0.4); Vipi Wave without fiber (16.60 ± 0.8); Vipi Wave with fiber (17.25 ± 0.9); Vipi Cril without fiber (17.78 ± 2.27); Vipi CRILL with fiber (18.02 ± 1.0 ); Lucitone without fiber (15.72 ± 0.3); Lucitone with fiber (16.69 ± 0.6), QC-20 without fiber (15.91 ± 0.4) and QC-20 with fiber (15 , 63 ± 0.2). Means and standard deviations to test elastic modulus were Vipi Flash without fiber (2952.76 ± 292.12); Flash Vipi with fiber (3373.49 ± 403.76); Vipi Wave without fiber (2511.69 ± 304.09); Vipi Wave with fiber (3225.01 ± 248.66); Vipi Cril without fiber (2745.61 ± 288.86); Vipi CRILL with fiber (3671.67 ± 329.91); Lucitone without fiber (1904.53 ± 149.05); Lucitone with fiber (3056.87 ± 126.11), QC-20 without fiber (1913.86 ± 147.80) and QC-20 with fiber (2858.32 ± 185 26). Means and standard deviations for flexural strength were Vipi Flash without fiber (81.62 ± 4.82); Flash Vipi with fiber (83.98 ± 4.98); Vipi Wave without fiber (83.52 ± 8 , 79); Vipi Wave with fiber (88.98 ± 8.47); Vipi Cril without fiber (64.17 ± 5.46); Vipi CRILL with fiber (93.37 ± 9.97); Lucitone without fiber ( 74.71 ± 9.43); Lucitone with fiber (87.29 ± 4.73), QC-20 without fiber (75.80 ± 8.82) and QC-20 with fiber (81.67 ± 12.97). Conclusion: the conclusion is that the incorporation of fibers resulted in changes in almost all properties examined, and thus easily used as an additional reinforcement for acrylic resins. With respect to the surface roughness of acrylic resins by thermo water bath and microwave thermo heat showed higher values when compared with acrylic resin. Moreover, the addition of glass fiber particulate increased the roughness values of some acrylic resins Vipi CRILL, Vipi Flash and Vipi Wave and remained constant in the resins Lucitone and QC-20. The addition of glass fiber does not increase significantly the microhardness in the groups. With respect to flexural strength glass fiber particulate significantly increased all values, as well as the modulus of acrylic resin reinforced by the addition of glass fibers.
|
56 |
Resist?ncia ? fratura de molares tratados endodonticamente restaurados com diferentes t?cnicas diretasZambiasi, Bianca Soares 26 January 2018 (has links)
Submitted by PPG Odontologia (odontologia-pg@pucrs.br) on 2018-06-04T18:19:16Z
No. of bitstreams: 1
BIANCA_SOARES_ZAMBIASI_DIS.pdf: 758503 bytes, checksum: 8be0192f396b8b0f4c6df98b83a9d972 (MD5) / Rejected by Sheila Dias (sheila.dias@pucrs.br), reason: Devolvido devido ? falta de capa institucional no arquivo em PDF. on 2018-06-14T17:04:02Z (GMT) / Submitted by PPG Odontologia (odontologia-pg@pucrs.br) on 2018-06-26T12:16:19Z
No. of bitstreams: 1
BIANCA_SOARES_ZAMBIASI_DIS.pdf: 578649 bytes, checksum: c63b0e7591fc3dce9a38312f414e4e43 (MD5) / Approved for entry into archive by Sheila Dias (sheila.dias@pucrs.br) on 2018-07-02T16:48:43Z (GMT) No. of bitstreams: 1
BIANCA_SOARES_ZAMBIASI_DIS.pdf: 578649 bytes, checksum: c63b0e7591fc3dce9a38312f414e4e43 (MD5) / Made available in DSpace on 2018-07-02T16:57:34Z (GMT). No. of bitstreams: 1
BIANCA_SOARES_ZAMBIASI_DIS.pdf: 578649 bytes, checksum: c63b0e7591fc3dce9a38312f414e4e43 (MD5)
Previous issue date: 2018-01-26 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior - CAPES / Aims: To evaluate, in vitro, the fracture resistance and the pattern of failure of endodontically treated molars restored with different direct restorative techniques. Materials and methods: 70 third healthy molars extracted were divided into 7 groups (n = 10): (all groups except H received root canal treatment) H-sound; Z250PT ? horizontally transfixed fiberglass post + Z250 composite resin; Z250FO ? Z250 + occlusal fiberglass tape; Z250FP ? Z250 + fiberglass tape along the floor of the pulp chamber; PREP-only cavity preparation; COL ?
Restored with Coltosol. After the restorative procedures, the samples were subjected to 250,000 cycles of mechanical testing fatigue under 200N. Right after, the samples were submitted to the fracture resistance testing and the analysis of the type of fracture which were classified as follows: Pulp chamber floor (non-repairable) or cusps (repairable). Results: (means (N) followed by the same letter do not present statistical difference to ANOVA and Tukey (p > 0.05): H 3832A; Z250PT 2726B; Z250FO 1647C; Z250FP 1548C; Z250 1622C; PREP 514D; COL 450D. Conclusion: The restorative technique that presents higher resistance to the fracture as well as higher percentage of repairable failures is
horizontal transfixing with fiberglass post, Z250PT group. The insertion of fiberglass tape into the composite resin did not present improvement in the resistance, nor in the fracture pattern, when compared to the use of traditional composite resin. / Objetivo: Avaliar, in vitro, a resist?ncia ? fratura e o padr?o de falha de dentes tratados endodonticamente restaurados com diferentes t?cnicas restauradoras diretas. Materiais e M?todos: Setenta terceiros molares h?gidos extra?dos foram divididos em 7 grupos (n=10) assim distribu?dos: (todos os grupos exceto H receberam endodontia) H- h?gidos; Z250PT ? pino de fibra de vidro transfixado horizontalmente + resina composta Z250; Z250FO ? Z250+fita de fibra de vidro oclusal; Z250FP ? Z250 + fita de fibra de vidro junto ao assoalho da c?mara pulpar; PREP ? apenas preparo cavit?rio; COL ? restaurado com material provis?rio Coltosol. Ap?s o t?rmino das restaura??es as amostras foram submetidas a 250 mil ciclos de fadiga mec?nica sob 200N. Em seguida, foi realizado o ensaio de resist?ncia ? fratura e a an?lise do tipo de fratura p?sensaio as quais foram classificadas em: assoalho da c?mara pulpar (irrepar?vel) ou c?spides (repar?vel). Resultados: (m?dias (N) seguidas de mesma letra n?o apresentam diferen?a estat?stica para ANOVA e Tukey (p>0,05): H 3832A;
Z250PT 2726B; Z250FO 1647C; Z250FP 1548C; Z250 1622C; PREP 514D; COL 450D. Conclus?o: A t?cnica restauradora que apresenta maior resist?ncia ? fratura. bem como maior percentual de falhas repar?veis ? a transfixa??o horizontal com pino de fibra de vidro, grupo Z250PT. A inser??o de fita de fibra de vidro na resina composta n?o apresentou melhora na resist?ncia, nem no padr?o de fratura, quando comparado a utiliza??o de resina composta tradicional.
|
57 |
Comparação entre cimentos resinosos e uma resina \"bulk fill\" na cimentação de pinos de fibra de vidro - Análise de resistência adesiva e dureza / Comparison between resin cements and a \"bulk fill\" resin composite on the luting of fiberglass- reinforced posts cementation - Bond strength and hardness analysisLobo, Tamile Rocha da Silva 29 January 2018 (has links)
Este estudo comparou a performance de quarto agentes cimentantes com diferentes estratégias adesivas para cimentação de pinos de fibra de vidro em canais radiculares, através do teste de resistência adesiva e avaliando a dureza em diferentes profundidades. Para isto, foram utilizadas 60 raízes bovinas tratadas endodonticamente. Foram cimentados pinos de fibra de vidro Rebilda Post 20 de acordo com os seguintes protocolos divididos nos seguintes grupos: Grupos QM: Adesivo autocondicionante dual Futurabond DC + cimento resinoso dual Bifix QM; Group SE: Cimento resinoso autocondicionante de polimerização dual Bifix SE; Group RB: Adesivo autocondicionante de polimerização dual Futurabond DC + Resina Rebilda; Group XB: aplicação do adesivo autocondicionante de polimerização dual Futurabond DC + resina composta do tipo \"bulk fill\" X-tra Base. As raízes foram cortadas em fatias de 1mm e separadas em terços, sendo obtidos 2 corpos de prova por terço. Foram avaliadas a resistência adesiva (n=10) e a microdureza (n=5), após uma semana e após 4 meses de armazenamento em água. Para o teste de resistência adesiva (push- out) uma fatia de cada terço foi testada depois de uma semana e as outras 3 fatias provenientes do mesmo dente avaliadas após 4 meses. O ensaio de push out foi realizado a uma velocidade de 0,5mm/min até o deslocamento do pino e/ou fratura da interface adesiva. Para o teste de microdureza 20 dentes foram selecionados aleatoriamente e de cada dente foram obtidas seis 6 fatias que foram armazenadas em água destilada por uma semana até a mensuração em microdurômetro, após uma semana e após 4 meses. Os corpos de prova foram submetidos ao teste de microdureza Knoop em microdurômetro HMV-2000 (Shimadzu, Tokyo, Japan), cinco endentações foram realizadas na camada de cimento de cada fatia. Os dados referentes aos testes de resistência adesiva (push- out) e microdureza foram submetidas análise de variância 3 fatores (ANOVA), teste de tukey (p<0,05) e teste de correlação de Person. Os valores de resistência adesiva não apresentaram diferenças estatísticas significantes quando observado os valores de resistência adesiva entre os grupos QM, RB e XB (p>=0.05), porém menores valores de resistência adesiva foram observados no Grupo SE. Quando considerada a variável envelhecimento não foram encontradas diferenças na resistência adesiva medida em uma semana e 4 meses (p>=0.05). Para a microdureza diferenças estatisticamente significantes foram encontradas nos diferentes terços da raiz (p<0.05). Os agentes cimentantes apresentaram diferenças estatísticas significantes na dureza (p<0.05). O grupo XB apresentou os maiores valores seguido por QM, RB e SE. Os grupos SE, RB e XB não apresentaram 80% da dureza máxima nas fatias correspondentes a região apical do canal radicular. O teste de Person mostrou haver correlação positiva linear entre a resistência adesiva e a dureza medidas antes e após o envelhecimento. O uso cimento resinoso dual, associado a uma aplicação anterior do sistema adesivo, ainda é a escolha mais segura, pois apresentou valores de força de adesão elevados, associados a valores de dureza adequados, mesmo em regiões apicais do canal radicular. / This study compared the performance of four cementitious agents with different adhesive strategies for cementing fiberglass pins in root canals, through the adhesive strength test and evaluating the hardness at different depths. For this, 60 endodontically treated bovine roots were used. Rebilda Post 20 fiberglass pins were cemented according to the following protocols divided into the following groups: QM groups: dual self-etching adhesive Futurabond DC + resin cement Bifix QM; Group SE: Dual polymerization resin cement Bifix SE; Group RB: application of self-etching dual-polymerization adhesive Futurabond DC + resin Rebilda; Group XB: application of the self-etching adhesive for dual polymerization Futurabond DC + composite resin of the bulk fill type X-tra Base. The roots were cut into 1mm slices and separated into thirds, obtaining 2 specimens per third. Bond strength (n =10) and microhardness (n = 5) were evaluated after one week and after 4 months of storage in water. For the push-out test one slice of each third was tested after one week and the other 3 slices from the same tooth evaluated after 4 months. The push out test was performed at a speed of 0.5mm / min until the pin displacement and / or fracture of the adhesive interface. For the microtensile test, 20 teeth were randomly selected and six slices were obtained from each tooth, which were stored in distilled water for one week until microdurometer measurement, after one week and after four months. The specimens were submitted to the Knoop microhardness test in HMV-2000 microdurometer (Shimadzu, Tokyo, Japan), five indentations were performed in the cement layer of each slice. The data for the tests of bond strenght (push-out) and microhardness were submitted to analysis of variance 3 factors (ANOVA) and Tukey test (p <0.05) and Person correlation test. The bond strength values did not present significant statistical differences when the adhesive strength values were observed between the groups QM, RB and XB (p>=0.05), but lower values of adhesive strength were observed in the SE Group. When the aging variable was considered, differences in adhesive strength measured at one week and 4 months (p>=0.05) were not found. For microhardness, statistically significant differences were found in the different thirds of the root (p <0.05). The cementing agents presented significant statistical differences in the hardness (p <0.05). The XB group presented the highest values followed by QM, RB and SE. The groups SE, RB and XB did not present 80% of the maximum hardness in the slices corresponding to the apical region of the root canal. The Person test showed a linear positive correlation between the adhesive strength and the hardness measured before and after aging. The use of dual resin cement, combined with a previous application of the adhesive system, is still the safest choice, since it presented high values of bond strength, associated with adequate hardness values, even in apical regions of the root canal.
|
58 |
EFEITO DA DENSIDADE DE ENERGIA DA LUZ NA ADESÃO ENTRE PINOS DE FIBRA E DENTINA RADICULAR / Effects of energy density of light-activation of adhesive systems on bonding fiber posts to root canalsSzesz, Anna Luiza 25 February 2014 (has links)
Made available in DSpace on 2017-07-24T19:22:35Z (GMT). No. of bitstreams: 1
ANNA LUIZA SZESZ.pdf: 3989892 bytes, checksum: 237bfbd8af89362f6139a3c445f884d8 (MD5)
Previous issue date: 2014-02-25 / This study evaluated, the intensity of light transmitted through a translucent fiber post ( Whitepost DC n° 2) using an experimental system and the effect of different
densities of light energy in adhesive properties: degree of conversion within the hybrid layer (DC), nanoleakage (NL) and bond strength (μTBS) of two adhesive systems to dentin (Ambar [AM] and Excite DSC [EX]). The roots of 72 human premolars were prepared endodontically and divided into groups (n=6) according to the combination of factors: adhesive system (AM and EX) and energy density (16, 48 and 288 J/cm²). After cementing fiber post the roots with fiber post were subjected to μTBS (push-out) (n = 7) in a universal testing machine (0.5 mm/min). DC analysis (%) in situ (n = 2) was made by micro -Raman spectroscopy and NL was evaluated by SEM after immersing the samples in 50% silver nitrate (n=3). Data from the μTBS, NL, and DC of each adhesive were analyzed by 3-way repeated measures ANOVA (adhesive vs. Energy density vs. root third) and Tukey test (α = 0.05) . To measure the intensity of light transmitted through the post, the measuring device consisted of a light beam pulsed laser focusing perpendicular to the bottom surface of the post, and in the direction parallel to the axis of the post detector capable of measuring the scattered light at the post. To simulate the variation of light intensity, filters were used in this system with optical density varying the light intensity of 100, 25 and 10%. The results of μTBS (MPa) showed a significant difference for the middle and apical (p <0.05) thirds when an increase in energy density from 16 to 48 and 288 J/cm²respectively. The DC (%) significantly increased the density of 288 J/cm² in the
middle and apical thirds compared the same with the lower energy density of 16 J/cm² (p < 0.05). The NL (%) decreases significantly from the energy density of 48
J/cm² in the middle and apical (p thirds < 0.05) and remained constant for the density of 288 J/cm² (p > 0.05), in general, none of the tests results showed a significant
difference when the cervical third was evaluated . Regarding the results of the intensity of light scattered by the post, light intensity reduced to 45,5% in the cervical
region, to 14,2% and 5,3% in the middle and apical thirds, respectively. As for simulating the variation of light intensity, it was observed that the increase of the intensity of light incident on the base of the cervical post provides a gain of intensity of light reaching the apical level. / Este estudo avaliou, através de um sistema experimental, a intensidade de luz transmitida por um pino de fibra translúcido (Whitepost DC n°2) e o efeito de diferentes densidades de energia da luz nas propriedades adesivas: grau de conversão no interior da camada híbrida (GC), nanoinfiltração (NI) e resistência de união (RU) à dentina de dois sistemas adesivos (Ambar [AM] e Excite DSC [EX]). As raízes de 72 pré-molares humanos foram preparadas endodonticamente e divididas em grupos (n=6) de acordo com a combinação dos principais fatores: sistema
adesivo (AM e EX), e densidade de energia (16, 48 e 288 J/cm²). Após cimentação dos pinos de fibra, foi testado a RU (push-out) (n=7) em uma máquina de ensaios
universal (0,5 mm/min). A análise do GC (%) in situ (n=2) foi feita através da espectroscopia micro-Raman e a NI foi avaliada por MEV após a imersão das amostras em 50% em nitrato de prata (n=3). Os dados de RU, GC e NI de cada adesivo foram analisados por ANOVA de 3 fatores de medidas repetidas (adesivo vs. densidade de energia vs. terço radicular) e teste de Tukey (α = 0,05). Para
mensuração da intensidade de luz transmitida pelo pino, o sistema era constituído por um feixe de luz laser pulsado incidindo perpendicularmente a superfície da base do pino, e na direção paralela ao eixo do pino um detector capaz de mensurar a luz espalhada no pino. Para simular a variação da intensidade de luz foram utilizados
junto a esse sistema filtros de densidade óptica, variando a intensidade de luz em 100, 25 e 10%. Os resultados de RU (MPa) demonstraram diferença significativa para os terços médio e apical (p < 0,05) quando houve aumento da densidade de energia de 16 para 48 e 288 J/cm² respectivamente. O GC (%) aumentou significativamente na densidade de 288 J/cm² nos terços médio e apical quando comparado os mesmos terços com a menor densidade de energia 16 J/cm² (p <0,05). A NI (%) diminui significativamente a partir da densidade de energia de 48
J/cm² nos terços médio e apical (p < 0,05) e se manteve constante para a densidade de 288 J/cm² (p > 0,05). Em geral, nenhum dos testes apresentaram resultados com
diferença significativa quando o terço cervical foi avaliado. Em relação aos resultados da intensidade da luz espalhada pelo pino observamos que na região cervical a intensidade de luz reduz para 45,5 % no terço médio para 14,2 % e para apical 5,3%. Quanto a simulação da variação da intensidade da luz, foi possível observar que o aumento da intensidade de luz incidente na base cervical do pino proporciona um ganho de intensidade de luz que chega ao nível apical.
|
59 |
Caracterização de materiais compostos por ultra-som. / Ultrasonic characterization of composite materials.Boeri, Daniel Verga 19 April 2006 (has links)
Este trabalho apresenta duas técnicas de ensaios não-destrutivos por ultra-som realizados em um tanque com água para determinar as constantes elásticas de materiais compostos de fibra de vidro/epóxi. A primeira técnica é a transmissão direta utilizando um par de transdutores. A segunda é a técnica de pulso-eco, utilizando um único transdutor. A água do tanque atua como um acoplante para transferir a energia mecânica do transdutor para a amostra. Como o transdutor não fica em contato direto com a amostra, pode-se garantir um acoplamento constante. O sistema de medição dota de um dispositivo que permite medir a velocidade da onda elástica sob diferentes ângulos de incidência, através da rotação manual da amostra. Devido ao fenômeno de conversão de modos com incidência oblíqua na interface amostra-água, ensaios por ultra-som em tanques com água fornecem as informações necessárias para o cálculo das constantes elásticas em amostras de materiais anisotrópicos, numa dada direção, a partir das medições das velocidades longitudinal e de cisalhamento. Numa dada direção de propagação em um meio anisotrópico, existem três ondas elásticas distintas: uma longitudinal e duas de cisalhamento. Se as constantes elásticas do material são conhecidas, é possível obter as três velocidades em uma dada direção bastando resolver a equação de Christoffel. Invertendo a equação de Christoffel, obtém-se as constantes elásticas a partir das velocidades medidas em uma dada direção. Os experimentos são realizados com amostras de fibra de vidro/epóxi unidirecionais e bidirecionais, utilizando transdutores com freqüências de 0,5 MHz, 1 MHz e 2,25 MHz. Os resultados experimentais obtidos utilizando ambas as técnicas são comparados com um modelo denominado Regra das Misturas" e com resultados da literatura. / In this work, two ultrasonic non destructive techniques were implemented in a water tank and used to determine the elastic constants of glass-epoxy composites samples. The first is the through-transmission technique implemented with a pair of ultrasonic transducers. The second is the back-reflection technique that uses a single transducer in pulse-eco mode. The water acts as a couplant and transfers the mechanical energy from the transducer to the sample. As the transducer is not in direct contact with the sample, we can guarantee a good coupling with the immersion technique. With the system device, it is possible to measure the velocities of the elastic waves in different angles by manually rotating the sample. Due to wave mode conversion phenomenon at the sample-water interface with oblique incidence, ultrasonic immersion testing provides information to calculate the elastic constants of the specimen by measuring longitudinal and shear wave speeds. There are three different modes of waves, one longitudinal and two shear waves, for any given direction of propagation in an anisotropic medium. If the elastic constants of a medium are known, it is possible to obtain the three wave speeds in particular propagations directions by solving the Christoffel equation. Inverting the Christoffel equation, it is possible to obtain the elastic constants from the measured wave speed in several specific directions of the anisotropic material. Measurements were carried out on unidirectional and bidirectional glass-epoxy composite samples, using transducers with central frequency of 0.5 MHz, 1 MHz, and 2.25 MHz. The experimental results obtained with both techniques are compared with a model denominated Rule of Mixture" estimation and with the literature.
|
60 |
Resistência de união de cimentos resinosos à dentina previamente submetida a radioterapia / Bonding strength of resin cements to the dentin previously submitted to radiotherapyYamin, Paulo André 02 February 2017 (has links)
Este estudo avaliou, in vitro, a influência da radioterapia na resistência de união (RU) e na interface adesiva entre diferentes cimentos resinosos e dentina radicular. Sessenta caninos superiores foram distribuídos em 2 grupos (n=30) de acordo com a irradiação: não irradiados e irradiados. Os dentes do grupo irradiado foram submetidos à radioterapia com raios-X de 6 MV em frações de 2 Gy, com 30 ciclos, perfazendo 60 Gy. Os dentes foram seccionados para obtenção de raízes com 16 mm de comprimento, sendo realizado em seguida o preparo biomecânico com instrumento Reciproc R50 e obturação pela técnica de condensação lateral com cimento a base resina epóxica. Cada grupo foi subdividido de acordo com o cimento resinoso utilizado para a cimentação dos pinos de fibra de vidro (n=10): RelyX U200; Panavia F 2.0; RelyX ARC. Os pinos foram submetidos a tratamento de superfície com ácido fluorídrico 10% e cimentados de acordo com as recomendações de cada fabricante. Após a cimentação dos pinos, os dentes foram seccionados transversalmente em slices de 1 mm de espessura, obtendo-se 3 slices de cada terço da raiz. Os slices mais cervicais de cada terço foram utilizados para avaliar a RU, por meio do teste de push-out com velocidade de 0,5 mm/min, e posterior análise do padrão de falha em estereomicroscópio. Os slices mais apicais de cada terço foram selecionados para análise da interface cimento/dentina em MEV com aumentos de 100, 1000, 2000 e 4000X. Os dados de RU e adaptação da interface cimento/dentina foram submetidos à análise estatística pelos testes de ANOVA e Tukey, e Kruskal-Wallis e Duns, respectivamente. Os espécimes irradiados apresentaram menores valores de RU (8,23±4,26) comparados aos dentes não irradiados (11,88±6,42) (p<0,00001). Quanto aos cimentos resinosos, o RelyX U200 apresentou maiores valores na RU (15,17±5,89) comparado aos cimentos RelyX ARC (7,68±4,22) (p<0,0001) e Panavia F 2.0 (7,32±2,71) (p<0,0001). O terço cervical apresentou maiores valores de RU (13,08±6,10) comparado aos terços médio (9,72±5,03) e apical (7,38±4,53) (p<0,0001). O padrão de falhas mostrou ocorrência de falhas coesivas na dentina para os espécimes irradiados. Na análise da interface cimendo/dentina por MEV, observou-se maior desadaptação nos dentes submetidos à radioterapia. Em relação aos cimentos resinosos, foi observada maior adaptação com RelyX U200 e RelyX ARC comparados à Panavia F 2.0. Na análise qualitativa em MEV observou-se presença de fraturas e microfraturas na dentina radicular e menor presença de fibras colágenas em dentes irradiados. Para o cimento resinoso RelyX U200 e Panavia F 2.0 observou-se interface justaposta do cimento com a dentina radicular em dentes irradiados e não irradiados, sendo que para o cimento resinoso RelyX ARC foi observada formação de camada híbrida e tags de maneira similar para dentes irradiados e não irradiados. Concluiu-se que a radioterapia resultou na redução da resistência de união e na maior desadaptação da interface cimento resinoso/dentina radicular e que o cimento resinoso autoadesivo se apresentou como melhor alternativa para cimentação de pinos de fibra de vidro em dentes irradiados. / This in vitro study, evaluated the influency of radiotherapy on bond strength (BS) and adhesive interface between different resin cements and root dentin. Sixty maxillary canines were selected and distributed into two groups (n = 30) according to the irradiation protocol: non-irradiated and irradiated. The irradiated group were submitted to X-ray radiotherapy of 6 MV in fractions of 2 Gy, with 30 cycles, until complete 60 Gy. The teeth were sectioned to obtain 16 mm of root length, followed by biomechanical preparation with R50 reciproc instrument and obturation using the lateral condensation technique with epoxy resin-based sealer. Then, each group was subdivided according to the resin cement used for the glass fiber post cementation (n = 10): RelyX U200, Panavia F 2.0 and RelyX ARC. The posts were submitted to surface treatment with 10% hydrofluoric acid, and then cemented according to the manufacturer instructions. After the posts cementation, the teeth were sectioned transversely into 1 mm thick slices, and 3 slices were obtained from each root third. The most cervical slice of each third was used to evaluate the BS by the push-out test at 0.5 mm/min of velocity and the failure pattern was analyzed using stereomicroscopy. The most apical slice of each third was selected for SEM analysis, which were prepared and metalized. The dentin/cement interface analysis was performed at the following magnification: 100, 1000, 2000 and 4000X. The BS data and dentin/cement interface adaptation were submitted to statistical analysis by ANOVA, Tukey and Kruskal-Wallis, and Duns tests respectively. The irradiated specimens had lower BS values (8.23 ± 4.26) compared to non-irradiated group (11.88 ± 6.42) (p <0.00001). Regarding the resin cements, the RelyX U200 showed the higher values in BS (15.17 ± 5.89) compared to RelyX ARC (7.68 ± 4.22) and Panavia F 2.0 (7 , 32 ± 2.71) (p <0.0001). In addition, the cervical third presented higher BS values (13.08 ± 6.10) when compared to the middle (9.72 ± 5.03) and apical (7.38 ± 4.53) thirds (p <0.0001). The failure pattern showed cohesive failures in root dentin of the irradiated specimens. In the SEM dentin/cement interface analysis, a greater misadaptation was observed for the teeth submitted to radiotherapy. Regarding the resin cements, a better adaptation was observed for the RelyX U200 and RelyX ARC compared to the Panavia F 2.0. In the SEM qualitative analysis of the irradiated teeth, was possible to observe the presence of fractures and microfractures in the root dentin and a small number of collagen fibers. The resin cements RelyX U200 and Panavia F 2.0 showed a juxtaposed interface of the cement with the root dentin in irradiated and non-irradiated teeth, being that for the RelyX ARC cement the presence of hybrid layer and tags was similar for irradiated and non-irradiated groups. It was concluded that the radiotherapy promoted reduction of the bond strength and increase the gaps in the dentin/resin cement interface and the self-adhesive resin cement is the best alternative for glass fiber posts cementation in irradiated teeth.
|
Page generated in 0.0844 seconds