• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 89
  • 4
  • Tagged with
  • 93
  • 93
  • 49
  • 40
  • 23
  • 23
  • 23
  • 20
  • 20
  • 20
  • 19
  • 18
  • 18
  • 17
  • 17
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
71

Avalia??o da estrutura de tecidos t?cnicos como elemento refor?ante em comp?sitos polim?ricos sistema poli?ster isoft?lico

Melo, Alan Jones Lira de 23 July 2013 (has links)
Made available in DSpace on 2014-12-17T14:58:20Z (GMT). No. of bitstreams: 1 AlanJLM_DISSERT.pdf: 1835050 bytes, checksum: 47bf4fbd76665d11995bd7eb5bd3522a (MD5) Previous issue date: 2013-07-23 / Materials known as technical textiles can be defined as structures designed and developed to meet specific functional requirements of various industry sectors, which is the case in automotive and aerospace industries, and other specific applications. Therefore, the purpose of this work presents the development and manufacture of polymer composite with isophthalic polyester resin. The reinforcement of the composite structure is a technical textile fabric made from high performance fibers, aramid (Kevlar 49) and glass fiber E. The fabrics are manufactured by the same method, with the aim of improving the tensile strength of the resulting polymer composite material. The fabrics, we developed some low grammage technical textile structures in laboratory scale and differentiated-composition type aramid (100%), hybrid 1 aramid fiber / glass (65/35%) and hybrid 2 aramid fiber / glass (85/15% ) for use as a reinforcing element in composite materials with unsaturated isophthalic polyester matrix. The polymer composites produced were tested in uniaxial tensile fracture surface and it?s evaluated by SEM. The purpose of this work characterize the performance of polymer composites prepared, identifying changes and based on resistance to strain corresponding to the mechanical behavior. The objectives are to verify the capability of using this reinforcement structure, along with the use of high performance fibers and resin in terms of workability and mechanical strength; verify the adherence of the fiber to the matrix and the fracture surface by electron microscopy scanning and determination of tensile strength by tensile test. The results indicate that, in a comparative study to the response of uniaxial tensile test for tensile strength of the composites and the efficiency of the low percentage of reinforcement element, being a technical textile fabric structure that features characteristic of lightness and low weight added in polymer composites / Os materiais denominados de tecidos t?cnicos podem ser definidos como estruturas projetadas e desenvolvidas com a fun??o de atender a requisitos funcionais espec?ficos de diversos setores da ind?stria com aplica??es espec?ficas. Nesse sentido, este trabalho apresenta o desenvolvimento e a fabrica??o de comp?sito polim?rico com resina poli?ster isoft?lico. O refor?o do comp?sito ? uma estrutura de tecido t?xtil t?cnico confeccionado com fibras de alto desempenho de aramida (Kevlar 49) e fibra de vidro E. Os tecidos s?o fabricados pelo mesmo m?todo, com o objetivo do aprimorar a resist?ncia a tra??o do material comp?sito polim?rico resultante. Os tecidos, foram desenvolvidos em escala laboratorial com baixa gramatura e composi??o diferenciada de aramida (100%), h?brido 1 fibra de aramida/vidro (65/35%) e h?brido 2 fibra de aramida/vidro (85/15%) para utiliza??o como elemento refor?ante em comp?sitos com matriz de poli?ster insaturada isoft?lico. Os comp?sitos polim?ricos produzidos foram ensaiados em tra??o uniaxial e sua superf?cie de fratura avaliada por MEV. A proposta do trabalho ? caracterizar o desempenho dos comp?sitos polim?ricos elaborados, identificando as altera??es e baseando-se na resist?ncia ao ensaio de tra??o correspondente a comportamento mec?nico. Os objetivos s?o verificar a potencialidade da utiliza??o desta estrutura de refor?o, juntamente com a utiliza??o das fibras de alto desempenho e a resina, em termos de trabalhabilidade e resist?ncia mec?nica; verificar a ader?ncia da fibra ? matriz e a superf?cie de fratura atrav?s de microscopia eletr?nica de varredura e determina??o de resist?ncia ? ruptura por ensaio de tra??o. Os resultados indicam que, em um estudo comparativo para a resposta dos ensaios mec?nicos de tra??o uniaxial h? resist?ncia ? ruptura dos comp?sitos e a efici?ncia da baixa porcentagem do elemento de refor?o, sendo uma estrutura de tecido t?xtil t?cnico que apresenta caracter?stica de leveza e baixa gramatura adicionada nos comp?sitos polim?ricos
72

Caracterização de materiais compostos por ultra-som. / Ultrasonic characterization of composite materials.

Daniel Verga Boeri 19 April 2006 (has links)
Este trabalho apresenta duas técnicas de ensaios não-destrutivos por ultra-som realizados em um tanque com água para determinar as constantes elásticas de materiais compostos de fibra de vidro/epóxi. A primeira técnica é a transmissão direta utilizando um par de transdutores. A segunda é a técnica de pulso-eco, utilizando um único transdutor. A água do tanque atua como um acoplante para transferir a energia mecânica do transdutor para a amostra. Como o transdutor não fica em contato direto com a amostra, pode-se garantir um acoplamento constante. O sistema de medição dota de um dispositivo que permite medir a velocidade da onda elástica sob diferentes ângulos de incidência, através da rotação manual da amostra. Devido ao fenômeno de conversão de modos com incidência oblíqua na interface amostra-água, ensaios por ultra-som em tanques com água fornecem as informações necessárias para o cálculo das constantes elásticas em amostras de materiais anisotrópicos, numa dada direção, a partir das medições das velocidades longitudinal e de cisalhamento. Numa dada direção de propagação em um meio anisotrópico, existem três ondas elásticas distintas: uma longitudinal e duas de cisalhamento. Se as constantes elásticas do material são conhecidas, é possível obter as três velocidades em uma dada direção bastando resolver a equação de Christoffel. Invertendo a equação de Christoffel, obtém-se as constantes elásticas a partir das velocidades medidas em uma dada direção. Os experimentos são realizados com amostras de fibra de vidro/epóxi unidirecionais e bidirecionais, utilizando transdutores com freqüências de 0,5 MHz, 1 MHz e 2,25 MHz. Os resultados experimentais obtidos utilizando ambas as técnicas são comparados com um modelo denominado “Regra das Misturas” e com resultados da literatura. / In this work, two ultrasonic non destructive techniques were implemented in a water tank and used to determine the elastic constants of glass-epoxy composites samples. The first is the through-transmission technique implemented with a pair of ultrasonic transducers. The second is the back-reflection technique that uses a single transducer in pulse-eco mode. The water acts as a couplant and transfers the mechanical energy from the transducer to the sample. As the transducer is not in direct contact with the sample, we can guarantee a good coupling with the immersion technique. With the system device, it is possible to measure the velocities of the elastic waves in different angles by manually rotating the sample. Due to wave mode conversion phenomenon at the sample-water interface with oblique incidence, ultrasonic immersion testing provides information to calculate the elastic constants of the specimen by measuring longitudinal and shear wave speeds. There are three different modes of waves, one longitudinal and two shear waves, for any given direction of propagation in an anisotropic medium. If the elastic constants of a medium are known, it is possible to obtain the three wave speeds in particular propagations directions by solving the Christoffel equation. Inverting the Christoffel equation, it is possible to obtain the elastic constants from the measured wave speed in several specific directions of the anisotropic material. Measurements were carried out on unidirectional and bidirectional glass-epoxy composite samples, using transducers with central frequency of 0.5 MHz, 1 MHz, and 2.25 MHz. The experimental results obtained with both techniques are compared with a model denominated “Rule of Mixture” estimation and with the literature.
73

Resistência de união de cimentos resinosos à dentina previamente submetida a radioterapia / Bonding strength of resin cements to the dentin previously submitted to radiotherapy

Paulo André Yamin 02 February 2017 (has links)
Este estudo avaliou, in vitro, a influência da radioterapia na resistência de união (RU) e na interface adesiva entre diferentes cimentos resinosos e dentina radicular. Sessenta caninos superiores foram distribuídos em 2 grupos (n=30) de acordo com a irradiação: não irradiados e irradiados. Os dentes do grupo irradiado foram submetidos à radioterapia com raios-X de 6 MV em frações de 2 Gy, com 30 ciclos, perfazendo 60 Gy. Os dentes foram seccionados para obtenção de raízes com 16 mm de comprimento, sendo realizado em seguida o preparo biomecânico com instrumento Reciproc R50 e obturação pela técnica de condensação lateral com cimento a base resina epóxica. Cada grupo foi subdividido de acordo com o cimento resinoso utilizado para a cimentação dos pinos de fibra de vidro (n=10): RelyX U200; Panavia F 2.0; RelyX ARC. Os pinos foram submetidos a tratamento de superfície com ácido fluorídrico 10% e cimentados de acordo com as recomendações de cada fabricante. Após a cimentação dos pinos, os dentes foram seccionados transversalmente em slices de 1 mm de espessura, obtendo-se 3 slices de cada terço da raiz. Os slices mais cervicais de cada terço foram utilizados para avaliar a RU, por meio do teste de push-out com velocidade de 0,5 mm/min, e posterior análise do padrão de falha em estereomicroscópio. Os slices mais apicais de cada terço foram selecionados para análise da interface cimento/dentina em MEV com aumentos de 100, 1000, 2000 e 4000X. Os dados de RU e adaptação da interface cimento/dentina foram submetidos à análise estatística pelos testes de ANOVA e Tukey, e Kruskal-Wallis e Duns, respectivamente. Os espécimes irradiados apresentaram menores valores de RU (8,23&plusmn;4,26) comparados aos dentes não irradiados (11,88&plusmn;6,42) (p<0,00001). Quanto aos cimentos resinosos, o RelyX U200 apresentou maiores valores na RU (15,17&plusmn;5,89) comparado aos cimentos RelyX ARC (7,68&plusmn;4,22) (p<0,0001) e Panavia F 2.0 (7,32&plusmn;2,71) (p<0,0001). O terço cervical apresentou maiores valores de RU (13,08&plusmn;6,10) comparado aos terços médio (9,72&plusmn;5,03) e apical (7,38&plusmn;4,53) (p<0,0001). O padrão de falhas mostrou ocorrência de falhas coesivas na dentina para os espécimes irradiados. Na análise da interface cimendo/dentina por MEV, observou-se maior desadaptação nos dentes submetidos à radioterapia. Em relação aos cimentos resinosos, foi observada maior adaptação com RelyX U200 e RelyX ARC comparados à Panavia F 2.0. Na análise qualitativa em MEV observou-se presença de fraturas e microfraturas na dentina radicular e menor presença de fibras colágenas em dentes irradiados. Para o cimento resinoso RelyX U200 e Panavia F 2.0 observou-se interface justaposta do cimento com a dentina radicular em dentes irradiados e não irradiados, sendo que para o cimento resinoso RelyX ARC foi observada formação de camada híbrida e tags de maneira similar para dentes irradiados e não irradiados. Concluiu-se que a radioterapia resultou na redução da resistência de união e na maior desadaptação da interface cimento resinoso/dentina radicular e que o cimento resinoso autoadesivo se apresentou como melhor alternativa para cimentação de pinos de fibra de vidro em dentes irradiados. / This in vitro study, evaluated the influency of radiotherapy on bond strength (BS) and adhesive interface between different resin cements and root dentin. Sixty maxillary canines were selected and distributed into two groups (n = 30) according to the irradiation protocol: non-irradiated and irradiated. The irradiated group were submitted to X-ray radiotherapy of 6 MV in fractions of 2 Gy, with 30 cycles, until complete 60 Gy. The teeth were sectioned to obtain 16 mm of root length, followed by biomechanical preparation with R50 reciproc instrument and obturation using the lateral condensation technique with epoxy resin-based sealer. Then, each group was subdivided according to the resin cement used for the glass fiber post cementation (n = 10): RelyX U200, Panavia F 2.0 and RelyX ARC. The posts were submitted to surface treatment with 10% hydrofluoric acid, and then cemented according to the manufacturer instructions. After the posts cementation, the teeth were sectioned transversely into 1 mm thick slices, and 3 slices were obtained from each root third. The most cervical slice of each third was used to evaluate the BS by the push-out test at 0.5 mm/min of velocity and the failure pattern was analyzed using stereomicroscopy. The most apical slice of each third was selected for SEM analysis, which were prepared and metalized. The dentin/cement interface analysis was performed at the following magnification: 100, 1000, 2000 and 4000X. The BS data and dentin/cement interface adaptation were submitted to statistical analysis by ANOVA, Tukey and Kruskal-Wallis, and Duns tests respectively. The irradiated specimens had lower BS values (8.23 &plusmn; 4.26) compared to non-irradiated group (11.88 &plusmn; 6.42) (p <0.00001). Regarding the resin cements, the RelyX U200 showed the higher values in BS (15.17 &plusmn; 5.89) compared to RelyX ARC (7.68 &plusmn; 4.22) and Panavia F 2.0 (7 , 32 &plusmn; 2.71) (p <0.0001). In addition, the cervical third presented higher BS values (13.08 &plusmn; 6.10) when compared to the middle (9.72 &plusmn; 5.03) and apical (7.38 &plusmn; 4.53) thirds (p <0.0001). The failure pattern showed cohesive failures in root dentin of the irradiated specimens. In the SEM dentin/cement interface analysis, a greater misadaptation was observed for the teeth submitted to radiotherapy. Regarding the resin cements, a better adaptation was observed for the RelyX U200 and RelyX ARC compared to the Panavia F 2.0. In the SEM qualitative analysis of the irradiated teeth, was possible to observe the presence of fractures and microfractures in the root dentin and a small number of collagen fibers. The resin cements RelyX U200 and Panavia F 2.0 showed a juxtaposed interface of the cement with the root dentin in irradiated and non-irradiated teeth, being that for the RelyX ARC cement the presence of hybrid layer and tags was similar for irradiated and non-irradiated groups. It was concluded that the radiotherapy promoted reduction of the bond strength and increase the gaps in the dentin/resin cement interface and the self-adhesive resin cement is the best alternative for glass fiber posts cementation in irradiated teeth.
74

Comparação entre cimentos resinosos e uma resina \"bulk fill\" na cimentação de pinos de fibra de vidro - Análise de resistência adesiva e dureza / Comparison between resin cements and a \"bulk fill\" resin composite on the luting of fiberglass- reinforced posts cementation - Bond strength and hardness analysis

Tamile Rocha da Silva Lobo 29 January 2018 (has links)
Este estudo comparou a performance de quarto agentes cimentantes com diferentes estratégias adesivas para cimentação de pinos de fibra de vidro em canais radiculares, através do teste de resistência adesiva e avaliando a dureza em diferentes profundidades. Para isto, foram utilizadas 60 raízes bovinas tratadas endodonticamente. Foram cimentados pinos de fibra de vidro Rebilda Post 20 de acordo com os seguintes protocolos divididos nos seguintes grupos: Grupos QM: Adesivo autocondicionante dual Futurabond DC + cimento resinoso dual Bifix QM; Group SE: Cimento resinoso autocondicionante de polimerização dual Bifix SE; Group RB: Adesivo autocondicionante de polimerização dual Futurabond DC + Resina Rebilda; Group XB: aplicação do adesivo autocondicionante de polimerização dual Futurabond DC + resina composta do tipo \"bulk fill\" X-tra Base. As raízes foram cortadas em fatias de 1mm e separadas em terços, sendo obtidos 2 corpos de prova por terço. Foram avaliadas a resistência adesiva (n=10) e a microdureza (n=5), após uma semana e após 4 meses de armazenamento em água. Para o teste de resistência adesiva (push- out) uma fatia de cada terço foi testada depois de uma semana e as outras 3 fatias provenientes do mesmo dente avaliadas após 4 meses. O ensaio de push out foi realizado a uma velocidade de 0,5mm/min até o deslocamento do pino e/ou fratura da interface adesiva. Para o teste de microdureza 20 dentes foram selecionados aleatoriamente e de cada dente foram obtidas seis 6 fatias que foram armazenadas em água destilada por uma semana até a mensuração em microdurômetro, após uma semana e após 4 meses. Os corpos de prova foram submetidos ao teste de microdureza Knoop em microdurômetro HMV-2000 (Shimadzu, Tokyo, Japan), cinco endentações foram realizadas na camada de cimento de cada fatia. Os dados referentes aos testes de resistência adesiva (push- out) e microdureza foram submetidas análise de variância 3 fatores (ANOVA), teste de tukey (p<0,05) e teste de correlação de Person. Os valores de resistência adesiva não apresentaram diferenças estatísticas significantes quando observado os valores de resistência adesiva entre os grupos QM, RB e XB (p>=0.05), porém menores valores de resistência adesiva foram observados no Grupo SE. Quando considerada a variável envelhecimento não foram encontradas diferenças na resistência adesiva medida em uma semana e 4 meses (p>=0.05). Para a microdureza diferenças estatisticamente significantes foram encontradas nos diferentes terços da raiz (p<0.05). Os agentes cimentantes apresentaram diferenças estatísticas significantes na dureza (p<0.05). O grupo XB apresentou os maiores valores seguido por QM, RB e SE. Os grupos SE, RB e XB não apresentaram 80% da dureza máxima nas fatias correspondentes a região apical do canal radicular. O teste de Person mostrou haver correlação positiva linear entre a resistência adesiva e a dureza medidas antes e após o envelhecimento. O uso cimento resinoso dual, associado a uma aplicação anterior do sistema adesivo, ainda é a escolha mais segura, pois apresentou valores de força de adesão elevados, associados a valores de dureza adequados, mesmo em regiões apicais do canal radicular. / This study compared the performance of four cementitious agents with different adhesive strategies for cementing fiberglass pins in root canals, through the adhesive strength test and evaluating the hardness at different depths. For this, 60 endodontically treated bovine roots were used. Rebilda Post 20 fiberglass pins were cemented according to the following protocols divided into the following groups: QM groups: dual self-etching adhesive Futurabond DC + resin cement Bifix QM; Group SE: Dual polymerization resin cement Bifix SE; Group RB: application of self-etching dual-polymerization adhesive Futurabond DC + resin Rebilda; Group XB: application of the self-etching adhesive for dual polymerization Futurabond DC + composite resin of the bulk fill type X-tra Base. The roots were cut into 1mm slices and separated into thirds, obtaining 2 specimens per third. Bond strength (n =10) and microhardness (n = 5) were evaluated after one week and after 4 months of storage in water. For the push-out test one slice of each third was tested after one week and the other 3 slices from the same tooth evaluated after 4 months. The push out test was performed at a speed of 0.5mm / min until the pin displacement and / or fracture of the adhesive interface. For the microtensile test, 20 teeth were randomly selected and six slices were obtained from each tooth, which were stored in distilled water for one week until microdurometer measurement, after one week and after four months. The specimens were submitted to the Knoop microhardness test in HMV-2000 microdurometer (Shimadzu, Tokyo, Japan), five indentations were performed in the cement layer of each slice. The data for the tests of bond strenght (push-out) and microhardness were submitted to analysis of variance 3 factors (ANOVA) and Tukey test (p <0.05) and Person correlation test. The bond strength values did not present significant statistical differences when the adhesive strength values were observed between the groups QM, RB and XB (p>=0.05), but lower values of adhesive strength were observed in the SE Group. When the aging variable was considered, differences in adhesive strength measured at one week and 4 months (p>=0.05) were not found. For microhardness, statistically significant differences were found in the different thirds of the root (p <0.05). The cementing agents presented significant statistical differences in the hardness (p <0.05). The XB group presented the highest values followed by QM, RB and SE. The groups SE, RB and XB did not present 80% of the maximum hardness in the slices corresponding to the apical region of the root canal. The Person test showed a linear positive correlation between the adhesive strength and the hardness measured before and after aging. The use of dual resin cement, combined with a previous application of the adhesive system, is still the safest choice, since it presented high values of bond strength, associated with adequate hardness values, even in apical regions of the root canal.
75

AvaliaÃÃo da resistÃncia de uniÃo da interface adesiva de pinos de fibra de vidro e a dentina radicular / Bond strength at the adhesive interface of fiber glass posts and root dentin

Aminthas Alves Brasil Neto 30 March 2007 (has links)
nÃo hà / O objetivo deste trabalho foi avaliar a resistÃncia de uniÃo da interface adesiva de pinos de fibra de vidro e dentina radicular, em trÃs regiÃes do conduto, fixados com trÃs sistemas de cimentaÃÃo. Vinte e quatro dentes humanos hÃgidos, recÃm-extraÃdos por razÃes ortodÃnticas ou periodontais, tiveram suas coroas removidas na junÃÃo cemento-esmalte com um disco diamantado, sob irrigaÃÃo. As raÃzes receberam tratamento endodÃntico e foram obturadas com guta-percha e um cimento endodÃntico contendo eugenol (Endofil). A desobstruÃÃo foi realizada uma semana apÃs o tÃrmino do tratamento endodÃntico em uma profundidade de 9 mm medida da regiÃo cervical da raiz. O pino (Reforpost Fibra de Vidro n 3) foi cimentado no conduto radicular com um dos trÃs sistemas de fixaÃÃo descritos a seguir (n = 8): no grupo 1 foi utilizado o sistema Single Bond 2/ RelyX ARC, no grupo 2 foi utilizado o sistema ED Primer/Panavia 21 e no grupo 3 foi utilizado o cimento RelyX Unicem. Todos os cimentos e sistemas adesivos foram utilizados de acordo com as instruÃÃes dos fabricantes. Posteriormente, as raÃzes foram seccionadas em uma mÃquina de corte, sob irrigaÃÃo, em trÃs porÃÃes, correspondentes aos terÃos cervical, mÃdio e apical da regiÃo do conduto preparada para o pino. Os espÃcimes foram submetidos ao teste de extrusÃo por cisalhamento (âpush-outâ) em uma mÃquina de ensaio universal a uma velocidade de 0,5 mm/min e os valores de resistÃncia de uniÃo mÃxima foram registrados e submetidos à anÃlise estatÃstica (p < 0,05). A anÃlise de variÃncia (ANOVA) mostrou diferenÃa estatÃstica significante entre os terÃos (cervical, mÃdio e apical) somente para o grupo do cimento Panavia 21, no qual o terÃo apical apresentou menor mÃdia de resistÃncia de uniÃo do que os terÃos cervical e mÃdio (teste de Tukey). Quando se comparou a resistÃncia de uniÃo em cada regiÃo da raiz, avaliando-se os materiais de cimentaÃÃo, a anÃlise de variÃncia (ANOVA) mostrou diferenÃa estatÃstica significante para as trÃs regiÃes do conduto. Para os terÃos mÃdio e apical, o cimento Panavia 21 apresentou mÃdia de resistÃncia de uniÃo significativamente menor do que os cimentos Single Bond 2/RelyX ARC e RelyX Unicem, sendo estes estatisticamente iguais entre si. Para o terÃo cervical, o cimento RelyX Unicem apresentou maiores valores de resistÃncia de uniÃo do que o cimento Panavia 21, tendo sido o cimento Single Bond 2/RelyX ARC estatisticamente semelhante aos outros dois materiais / The aim of this study was to assess the bond strength at the adhesive interface of fiber glass posts and root dentin, in three regions of the canal, fixed with three cementation systems. Twenty-four healthy human teeth, recently extracted for orthodontic or periodontal reasons, had their crowns removed at the cement-enamel junction with a diamond disk, under irrigation. The roots were endodontically treated and were filled with gutta percha and an endodontic cement containing eugenol (Endofil). One week after endodontic treatment ended, the obstruction was removed at a mean depth of 9mm in the cervical region of the root. The posts (Reforpost Fibra de Vidro No. 3) were cemented in the canals prepared with one of the three fixation systems described as follows (n = 8): in group 1 the Single Bond 2/ RelyX ARC system was used; in group 2 the ED Primer/Panavia 21 system, and in group 3 RelyX Unicem cement was used. All the cements and adhesive systems were used in accordance with the manufacturersâ instructions. Afterwards, the roots were sectioned in a cutting machine under irrigation, into three portions corresponding to the cervical, middle and apical thirds of the root canal region prepared for the post. The specimens were submitted to the pushout test in a universal test machine at a speed of 0.5 mm/min and the maximum bond strength values were recorded and submitted to statistical analysis (p < 0.05). Analysis of variance (ANOVA) showed statistically significant difference between the cervical, middle and apical thirds only for the Panavia 21 cement group, in which the apical third presented a lower mean bond strength value than the cervical and middle thirds (the TukeyÂs test). When the bond strength in each region of the root was compared to assess the cementing materials, the analysis of variance (ANOVA) showed statistically significant different for the three regions of the canal. For the middle and apical thirds, the Panavia 21 cement presented significantly lower mean bond strength than the Single Bond 2/RelyX ARC and RelyX Unicem cements, these being statistically equal between them. For the cervical third, RelyX Unicem cement presented higher bond strength values than the Panavia 21 cement and the Single Bond 2/RelyX ARC cement was statistically equal to the other two materials
76

Comportamento biomecânico de pinos personalizados em remanescente dentário fragilizado / Biomechanical behavior of personalized posts in weakened dental roots

Kasuya, Amanda Vessoni Barbosa 02 March 2017 (has links)
Submitted by JÚLIO HEBER SILVA (julioheber@yahoo.com.br) on 2017-05-03T17:14:13Z No. of bitstreams: 3 Tese - Amanda Vessoni Barbosa Kasuya - 2017-1-50.pdf: 15013683 bytes, checksum: f8924a9fa740c813552a7c3316dba183 (MD5) Tese - Amanda Vessoni Barbosa Kasuya - 2017-51-111.pdf: 15359599 bytes, checksum: ea14f282d1609854707110f304682486 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Rejected by Luciana Ferreira (lucgeral@gmail.com), reason: olhe no guia a forma de nomear arquivos divididos on 2017-05-04T11:04:01Z (GMT) / Submitted by JÚLIO HEBER SILVA (julioheber@yahoo.com.br) on 2017-05-04T17:04:01Z No. of bitstreams: 3 Tese - Amanda Vessoni Barbosa Kasuya - 2017- Parte 1.pdf: 15013683 bytes, checksum: f8924a9fa740c813552a7c3316dba183 (MD5) Tese - Amanda Vessoni Barbosa Kasuya - 2017- Parte 2.pdf: 15359599 bytes, checksum: ea14f282d1609854707110f304682486 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Rejected by Luciana Ferreira (lucgeral@gmail.com), reason: No guia está registrado: - Quando o arquivo tiver que ser dividido, por ser grande, cada um deve ser renomeado da mesma forma, adicionando a indicação da parte, entre parênteses, no final. Exemplos: “Tese - João Alves da Silva - 2015 (1)”, “Tese - João Alves da Silva - 2015 (2)”. on 2017-05-05T12:44:32Z (GMT) / Submitted by JÚLIO HEBER SILVA (julioheber@yahoo.com.br) on 2017-05-05T16:53:52Z No. of bitstreams: 3 Tese - Amanda Vessoni Barbosa Kasuya - 2017- Parte 1.pdf: 15013683 bytes, checksum: f8924a9fa740c813552a7c3316dba183 (MD5) Tese - Amanda Vessoni Barbosa Kasuya - 2017- Parte 2.pdf: 15359599 bytes, checksum: ea14f282d1609854707110f304682486 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Rejected by Erika Demachki (erikademachki@gmail.com), reason: on 2017-05-05T17:13:14Z (GMT) / Submitted by JÚLIO HEBER SILVA (julioheber@yahoo.com.br) on 2017-05-05T17:15:42Z No. of bitstreams: 3 Tese - Amanda Vessoni Barbosa Kasuya - 2017 (1).pdf: 15013683 bytes, checksum: f8924a9fa740c813552a7c3316dba183 (MD5) Tese - Amanda Vessoni Barbosa Kasuya - 2017 (2).pdf: 15359599 bytes, checksum: ea14f282d1609854707110f304682486 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2017-05-08T15:51:39Z (GMT) No. of bitstreams: 3 Tese - Amanda Vessoni Barbosa Kasuya - 2017 (1).pdf: 15013683 bytes, checksum: f8924a9fa740c813552a7c3316dba183 (MD5) Tese - Amanda Vessoni Barbosa Kasuya - 2017 (2).pdf: 15359599 bytes, checksum: ea14f282d1609854707110f304682486 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2017-05-08T15:51:39Z (GMT). No. of bitstreams: 3 Tese - Amanda Vessoni Barbosa Kasuya - 2017 (1).pdf: 15013683 bytes, checksum: f8924a9fa740c813552a7c3316dba183 (MD5) Tese - Amanda Vessoni Barbosa Kasuya - 2017 (2).pdf: 15359599 bytes, checksum: ea14f282d1609854707110f304682486 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2017-03-02 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / The objectives of this work were to evaluate the stress distribution (SD), fracture resistance (RF), adhesive strength (AS) and their respective fracture patterns of weekeaned bovine roots, rehabilitated with customized pins with different resinous materials. In addition, the objective of this study was to evaluate the polymerization depth of the resinous materials by Knoop microhardness method (MH). Eight experimental groups were established (n = 10 for FR and AS; n = 5 for MH), with the factor under study: 1. The post type (industrialized glass fiber post relined (I) and personalized post (P), 2. the relining material only for industrialized glass fiber post (experimental composite (e) and composite resin (R)); 3. the material used only for personalized post (experimental composite (e) and bulk fill resin (b), and 4. the amount of remaining dentin (root embrittlement inner wear, in lengths of 5 mm or 10 mm). One hundred and forty bovine roots of similar size were selected and restored according to the group to which they belonged. For FR, Pperiodontal and alveolar bone were simulated and the specimens were placed in an Instron 5965 machine at a 135 ° angle to the long axis and loaded at a constant velocity of 0.5 mm/min in compression until the fracture. The fracture pattern was classified as: F1- crown; F2- root; F3- crown/root; F4- fracture with displacement of the crown/post. For AS, the specimens were sectioned in slices of 1 mm perpendicular to their long axis. Each specimen was placed in a test machine to received the load in the apical-coronal direction, at a constant velocity of 0.5mm / min, pushing the pin through the largest side of the sample until fracture. The fracture pattern was classified as: F1- cohesive of the pin and/or reline material; F2- cohesive of dentin; F3- adhesive of pin/reline material; F4 - Adhesive bonding cement/ eline material and F5 - mixed. For MH, the specimens were sectioned parallel to their long axis. The tests were performed with a Knoop penetrator under a static charge of 50 grams per 10 seconds. MH was calculated as the average value for each third. Finally, the finite element method was used to analyze the DT. 3D virtual models representative of each experimental group were created and analyzed under von Mises equivalent stresses criterion, simulating loading of 100N at a 45o angle with the long axis. The experimental composite proved to be an alternative for the rehabilitation of weakened roots when used to create personalized posts or when used as a relining material, with FR values similar to the traditional technique, but with more favorable stress distributions. Moreover, it presented excellent adhesive strength to the dentin structure, being comparable to conventional composite resin and bulk fill resin. The bulk fill resin resulted in low values of fracture resistance associated with the fracture and displacement of post/crown. Lower microhardness values were observed in the apical third for bulk fill resin. / Os objetivos deste trabalho foram avaliar a distribuição de tensões (DT), resistência à fratura (RF), resistência adesiva (RA) e seus respectivos padrões de fratura de raízes bovinas fragilizadas, reabilitadas com pinos personalizados com diferentes materiais resinosos. Além disso, objetivou-se avaliar a profundidade de polimerização dos materiais resinosos por meio do método de microdureza Knoop (MD). Oito grupos experimentais foram criados (n=10 para RF e RA; n=5 para MD), tendo como fator em estudo: 1. o tipo de pino utilizado (pino de fibra de vidro industrializado reembasado (I) e pino personalizado (P)); 2. o material de reembasamento apenas para os pinos industrializados (compósito experimental (e) e resina composta (r)); 3. o material utilizado para confecção apenas dos pinos personalizados (compósito experimental (e) e resina bulk fill (b)); e 4. a quantidade de dentina remanescente (fragilização radicular por desgaste interno nos comprimentos de 5 mm ou 10 mm). Cento e quarenta raízes bovinas com dimensões semelhantes foram selecionadas e restauradas de acordo com o grupo ao qual pertenciam. Para RF, ligamento periodontal e osso alveolar foram simulados e os espécimes posicionados em máquina Instron 5965, em um ângulo de 135° em relação ao longo eixo do dente de modo que recebessem carregamento à velocidade constante de 0,5mm/min em compressão até a fratura. Em seguida, o padrão de fratura foi classificado em: F1- coroa; F2- raiz; F3- coroa/raiz; F4- fratura com deslocamento do conjunto coroa/pino. Para RA, os espécimes foram seccionados em fatias 1 mm perpendicularmente ao seu longo eixo. Cada espécime foi posicionado em máquina de ensaio de modo que recebessem a carga no sentido apical-coronal, à velocidade constante de 0,5mm/min, empurrando o pino através do maior lado da amostra até a fratura. O padrão de fratura foi classificado em: F1 - coesiva do pino e/ou material de reembasamento; F2 - coesiva da dentina; F3 - adesiva pino/material de reembasmento; F4 - adesiva material de reembasamento/cimento e F5 – mista. Para MD, os espécimes foram seccionados paralelamente ao seu longo eixo. Os testes foram realizados com um penetrador Knoop sob uma carga estática de 50 gramas por 10 segundos. MD foi calculada como o valor médio para cada terço. E por fim, o método de elementos finitos foi empregado para analisar a DT. Modelos virtuais 3D representativos de cada grupo experimental foram criados e analisados sob critério de tensões equivalentes de von Mises, simulando carregamento de 100N em um ângulo de 45o com o longo eixo. O compósito experimental demostrou ser uma alternativa para a reabilitação de raízes fragilizadas quando utilizado para criar pinos personalizados ou quando utilizado como material de reembasamento de pinos, com valores de resistência à fratura semelhantes à técnica tradicional porém, com distribuição de tensões mais favoráveis. Além disso, apresentou excelente resistência adesiva à estrutura dentinária, sendo comparável à resina composta convencional e à resina bulk fill. Já a resina bulk fill resultou em baixos valores de resistência à fratura associado ao deslocamento do conjunto pino/coroa protética. Valores de microdureza inferiores foram observados no terço apical para a bulk fill.
77

Influência da terapia endodôntica e do envelhecimento artificial acelerado na resistência de união de pinos de fibra de vidro à dentina intrarradicular / Influence of endodontic therapy and artificial accelerated aging on fibreglass post bond strength to intraradicular dentine

Santana, Fernanda Ribeiro 28 May 2012 (has links)
Submitted by Luanna Matias (lua_matias@yahoo.com.br) on 2015-03-09T11:19:12Z No. of bitstreams: 2 Tese - Fernanda Ribeiro Santana - 2012.pdf: 12111889 bytes, checksum: 84cf2d3d0d514483cc202fde5fa79301 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Approved for entry into archive by Luanna Matias (lua_matias@yahoo.com.br) on 2015-03-09T14:09:39Z (GMT) No. of bitstreams: 2 Tese - Fernanda Ribeiro Santana - 2012.pdf: 12111889 bytes, checksum: 84cf2d3d0d514483cc202fde5fa79301 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Made available in DSpace on 2015-03-09T14:09:39Z (GMT). No. of bitstreams: 2 Tese - Fernanda Ribeiro Santana - 2012.pdf: 12111889 bytes, checksum: 84cf2d3d0d514483cc202fde5fa79301 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Previous issue date: 2012-05-28 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / Aim: To evaluate in vitro the influence of root canal instrumentation techniques, endodontic irrigants, endodontic sealers and artificial accelerated aging on fibreglass post bond strength to bovine intraradicular dentine. Methodology: Part 1. 120 bovine incisors were divided into 12 experimental groups (n=10) resulting from the interaction among 3 study factors: root canal instrumentation technique (RCPSS- root canal preparation with stainless steel instruments - KFile; RCPNiTi- root canal preparation with K3 Nickel-Titanium instruments), endodontic irrigant (NaOCl- 1% sodium hypochlorite; CHX- 2% chlorhexidine; O3- 1.2% ozonated water) (in all samples 17% EDTA was used to remove the smear layer) and specimens artificial accelerated aging (Immediate, test with no aging; Mediate, test performed after 2 months of water storage at 37°C). After root canal preparation, endodontic filling was not performed. Fibreglass posts were cemented with self-adhesive resin cement (RelyX U100, 3M-ESPE) and roots were cross-sectioned to obtain two slices of each third. Samples were submitted to micropush-out test and bond strength values (MPa) were analyzed by ANOVA in a split-plot arrangement and Tukey’s test (α = 0.05). Failure modes were evaluated under a confocal microscope. Part 2. 60 bovine incisors were divided into 6 experimental groups (n=10) resulting from the interaction between 2 study factors: endodontic sealer (Sx- Sealapex; S26- Sealer 26; AHAH Plus) and specimens artificial accelerated aging (Immediate, test with no aging; Mediate, test performed after 2 months of water storage at 37°C). Two control groups were employed (without root canal filling), represented by groups RCPNiTiNaOCl immediate and RCPNiTiNaOCl mediate of part 1 of the present study. In the six experimental groups, root canals were prepared 1mm from the apex with K3 Nickel-Titanium instruments associated with 1% sodium hypochlorite irrigation and 17% EDTA. They were then filled with gutta-percha and the specific sealer of each group, using the lateral compaction technique. Fibreglass posts were cemented with self-adhesive resin cement (RelyX U100, 3M-ESPE) and roots were cross-sectioned to obtain two slices of each third. Abstract xx Samples were submitted to micropush-out test and bond strength values (MPa) were submitted to ANOVA in a split-plot arrangement and Tukey’s test (α = 0,05). Comparisons with control groups were made using Dunnet test (α = 0.05). Failure modes were evaluated under a confocal microscope. Results: Part 1. In specimens submitted to water artificial aging, RCPNiTi presented higher bond strength values than RCPSS in apical third irrigated with NaOCl or CHX. Irrigation with NaOCl resulted in higher bond strength than O3. Artificial aging resulted in significant bond strength increase, except for middle and apical thirds of RCPSSO3 and apical of RCPNiTiO3. Bond strength significantly reduced in apical third. The prevalence of adhesive cement-dentine failure was verified in all groups. Part 2. Endodontic sealers showed no significant differences among them, however they presented significantly lower bond strength values than control groups (without filling), except in cervical third of groups tested immediately. Artificial aging did not interfere on bond strength to intraradicular dentine. There was a significant decrease on bond strength from cervical to apical third. The prevalence of adhesive cement-dentine failure was verified in all groups. Conclusions: Part 1. Root canal preparation with NiTi instruments associated with NaOCl irrigation and EDTA increased the bond strength of fiberglass posts cemented with self-adhesive resin cement to intraradicular dentine. Part 2. Endodontic sealers interfered negatively on bonding of fibreglass posts cemented with self-adhesive resin cement to intraradicular dentine. / Objetivo: Analisar in vitro a influência das técnicas de instrumentação do canal radicular, dos irrigantes e cimentos endodônticos e do envelhecimento artificial acelerado na resistência de união do pino de fibra de vidro à dentina intrarradicular em dentes bovinos. Metodologia: Parte 1. Cento e vinte incisivos bovinos foram divididos em doze grupos experimentais (n=10) resultantes da interação entre três fatores em estudo: técnica de instrumentação do canal radicular (PAI – preparo do canal radicular com instrumentos de aço inoxidável - K-File; PNiTi – preparo do canal radicular com instrumentos de Níquel-Titânio - K3); irrigante endodôntico (NaOCl- hipoclorito de sódio 1%; CHX- clorexidina 2%; O3- água ozonificada 1,2%) (em todas as amostras o EDTA 17% foi utilizado para a remoção de smear layer) e envelhecimento artificial acelerado dos espécimes (Imediato, teste sem envelhecimento; Mediato, teste após 2 meses de envelhecimento em água a 37°C). Após o preparo dos canais radiculares não foi realizada a obturação endodôntica. Pinos de fibra de vidro foram cimentados com cimento resinoso auto-adesivo (RelyX U100, 3M-ESPE) e as raízes foram seccionadas para obtenção de duas fatias de cada terço. As amostras foram submetidas ao teste de micropush-out e os dados de resistência de união (MPa) foram analisados por ANOVA com parcela subdividida e teste de Tukey (α = 0,05). Os padrões de falha foram avaliados por meio de microscopia confocal. Parte 2. Sessenta incisivos bovinos foram divididos em seis grupos experimentais (n=10) resultantes da interação entre dois fatores em estudo: cimento endodôntico (SX- Sealapex; S26- Sealer 26; AH- AH Plus) e envelhecimento artificial acelerado dos espécimes (Imediato, teste sem envelhecimento; Mediato, teste após 2 meses de envelhecimento em água a 37°C). Foram empregados dois grupos controles (sem obturação do canal radicular) representados pelos grupos PNiTiNaOCl imediato e PNiTiNaOCl mediato da parte 1 do presente estudo. Nos seis grupos experimentais os canais radiculares foram preparados 1mm aquém do ápice com instrumentos de Níquel-Titânio - K3 associado a Resumo xviii irrigação com NaOCl 1% e EDTA 17%. Em seguida, foram obturados com gutapercha e o cimento endodôntico específico de cada grupo, usando a técnica de condensação lateral. Pinos de fibra de vidro foram cimentados com cimento resinoso auto-adesivo (RelyX U100, 3M-ESPE) e as raízes foram seccionadas para obtenção de duas fatias de cada terço. As amostras foram submetidas ao teste de micropush-out e os dados de resistência de união (MPa) foram analisados por ANOVA com parcela subdividida e teste de Tukey (α = 0,05). Comparações com os grupos controles foram feitas pelo teste de Dunnet (α =0,05). Os padrões de falha foram avaliados por meio de microscopia confocal. Resultados: Parte 1. Nos espécimes submetidos ao envelhecimento artificial em água, PNiTi apresentou maiores valores de resistência de união que PAI no terço apical irrigado com NaOCL ou CHX. A irrigação com NaOCL resultou em maior resistência de união comparada a O3. O envelhecimento artificial resultou em aumento significante da resistência de união, exceto para os terços médio e apical de PAIO3 e apical de PNiTiO3. A resistência de união reduziu significativamente no terço apical. A prevalência de falha adesiva cimentodentina foi verificada em todos os grupos. Parte 2. Os cimentos endodônticos não mostraram diferenças significantes entre si, entretanto apresentaram valores de resistência de união significativamente menores que os grupos controles (sem obturação), exceto no terço cervical dos grupos testados imediatamente. O envelhecimento artificial não interferiu na resistência de união à dentina intrarradicular. Houve uma diminuição significante na resistência de união do terço cervical para o apical. A prevalência de falha adesiva cimentodentina foi verificada em todos os grupos. Conclusões: Parte 1. O preparo do canal radicular com instrumentos de NiTi associado a irrigação com NaOCl e uso do EDTA aumentou a resistência de união de pinos de fibra de vidro cimentados com cimento auto-adesivo à dentina intrarradicular. Parte 2. Os cimentos endodônticos interferiram negativamente na união de pinos de fibra de vidro cimentados com cimento auto-adesivo à dentina intrarradicular.
78

Estudo da viabilidade de fabricação de um tubo para construção de uma prótese de membro inferior em composito híbrido epóxi carbono-vidro / Viability of hybrid epoxi carbon-glass composite pipe manufacture for use in lower limb prosthesis

Guilherme Wolf Lebrão 01 March 2007 (has links)
Neste trabalho propôs-se a construção de um tubo de material compósito híbrido, com fibra de vidro e fibra de carbono, para utilização como prolongador de prótese de membro inferior a serem fabricadas pela AACD - Associação de Assistência à Criança Deficiente. O objetivo é avaliar as solicitações da prótese para otimizar custo e reduzir a massa. Fez-se inicialmente um levantamento das propriedades dos materiais comerciais utilizados para a fabricação do prolongador para referenciar o desenvolvimento do componente da prótese. Utilizou-se modelagem por elementos finitos para otimizar o componente em função dos esforços biomecânicos a que a prótese é submetida. Nesta modelagem, estudaram-se várias disposições, quantidade e material das camadas de forma a atender às solicitações e minimizar os custos. O levantamento bibliográfico permitiu encontrar uma rota de menor custo para a fabricação de compósito que utiliza um processo de transferência de resina auxiliado a vácuo e pré-formados de vidro e carbono. Como referência, foi fabricado um componente pelo processo de bobinagem filamentar que produz materiais compósitos de qualidade reconhecida. O processo de moldagem por transferência de resina assistido à vácuo, apesar de ter alguns insumos importados, pela sua simplicidade pode ser realizado na própria AACD e se mostrou capaz de obter componentes com custo que viabiliza sua produção sem grandes investimentos em equipamentos. Apesar da redução de algumas das propriedades em relação à peça de referência, o tubo apresentou vantagens na redução de massa e na absorção de impacto. / In this work it was considered a construction of a pipe of hybrid composite material, with carbon and glass fibre, for use as prosthesis extension of inferior member to be manufactured for the Associação de Assistência à Criança Deficiente AACD. The objective is to evaluate the requests of prosthesis to optimize cost and to reduce weight. A survey of the properties of the commercial materials commonly used for the manufacture extension became initially a reference to the development of the final component. A finite element modeling was used to optimize the component in the biomechanics function related to the efforts which the prosthesis is submitted. In this modeling some disposals and numbers of layers, amount and material have been studied to take care of the requests and to minimize the cost. A bibliographical survey allowed finding a shipper route for the manufacture of composite that uses a process of vacuum assisted resin transfer molding and preforms of glass with carbon. As reference, a component was produced using filament winding process to compare the quality of the obtained composite pipe. The process, although to have some imported feed-stock, can be proper carried out by AACD and if it showed capable to produce components with cost that makes possible its production internally. Despite the reduction of some of the properties in relation to the reference part, the component presented advantages such as weight reduction and the impact absorption.
79

Estudo do efeito da radiação ionizante sobre as propriedades da poliamida 6 com reforço de fibra de vidro / Study of the effect of ionizing radiation on properties of polyamide 6 with fibreglass reinforcement

Clovis Pinto 25 May 2007 (has links)
É cada vez maior a utilização de polímeros reforçados com fibra de vidro no mercado nacional. Entre eles utiliza-se a poliamida 6 que apresenta ótima resistência à tração, ao impacto e à absorção de umidade comparada à poliamida 6 sem reforço de fibra de vidro, sendo atualmente utilizada na indústria automobilística em peças sob o capô, em especial em carcaças de radiadores. Este trabalho foi realizado com o objetivo de estudar o efeito da radiação ionizante nas propriedades mecânicas (resistência à tração, à flexão e ao impacto Izod) e térmicas (resistência ao fio incandescente e temperatura de fusão) da poliamida 6 com reforço de fibra de vidro, submetida à diferentes doses de radiação (100 a 600 kGy). As amostras foram preparadas e irradiadas em um acelerador JOB 188 com feixe de elétrons de energia de 1,5 MeV em diferentes doses e uma taxa de dose de 22,61 kGy/h. Após a irradiação, as propriedades das amostras da poliamida 6 com reforço de fibra de vidro irradiada foram determinadas e comparadas com as amostras não irradiadas e constatou-se que as propriedades mecânicas de resistência à flexão e à tração aumentaram e a de resistência ao impacto diminuiu. Em relação à propriedade térmica de temperatura de fusão diminuiu de 224,4ºC para 212,5ºC mas a perda de massa diante do aumento constante da temperatura também diminuiu. Em relação à propriedade de resistência ao fio incandescente a poliamida 6 com reforço de fibra de vidro irradiada teve um bom desempenho. As imagens captadas por Microscopia Eletrônica de Varredura mostram que a irradiação provocou uma boa integração entre a fibra de vidro e o polímero o que foi responsável pelo bom desempenho na propriedade de resistência ao fio incandescente. / It is each time more common the use of polymers reinforced with fibreglass in the domestic market. Between them it is used polyamide 6 that it presents good tension resistance, to the impact and the humidity absorption compared with non-reinforced, being also at the present time used in the automobile industry in parts underneath the hood, especially in the radiator frames. The aim of this work is to study the effect of ionizing radiation on properties of polyamide 6 with fibreglass reinforcement, undergone to different radiation doses. Samples were prepared and irradiated on JOB 188 accelerator with an electron beam energy of 1.5 MeV in air with different doses (100 to 600 kGy) and a dose rate of 22.61 kGy/h. Afterward the irradiation, the properties of the samples of irradiated polyamide 6 with fibreglass reinforcement were evaluated and compared with the samples non-irradiated. It evidenced that the mechanical properties flexural resistance and tension resistance increased and the resistance to the impact decreased. Regarding the thermal properties of the temperature of fusing decreased of 224,4ºC for 212,5ºC but the loss of mass ahead of the constant increase of the temperature also decreased. In the property of resistance to the glow wire the polyamide 6 with fibreglass reinforcement had a good performance. The images caught for Scanning Electronic Microscopy show that the irradiation provoked a good integration enters the fibreglass and polymer what was responsible for the good performance in the property of resistance to the glow wire.
80

Resistência da união ao teste de push-out de cimentos resinosos auto-adesivos em dentina radicular / Push-out bond strength of self-adhesive resin cements on root dentin

Gonçalves, Mariella Agostinho 30 March 2012 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2016-05-18T14:35:18Z No. of bitstreams: 1 mariellaagostinhogoncalves.pdf: 2206097 bytes, checksum: 736acf1d28715f5b3a331257446b5b23 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2016-07-01T18:48:04Z (GMT) No. of bitstreams: 1 mariellaagostinhogoncalves.pdf: 2206097 bytes, checksum: 736acf1d28715f5b3a331257446b5b23 (MD5) / Made available in DSpace on 2016-07-01T18:48:04Z (GMT). No. of bitstreams: 1 mariellaagostinhogoncalves.pdf: 2206097 bytes, checksum: 736acf1d28715f5b3a331257446b5b23 (MD5) Previous issue date: 2012-03-30 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Neste estudo, avaliou-se a resistência da união ao push-out de dois cimentos resinosos auto-adesivos e de um cimento resinoso convencional em dentina radicular. Em 60 dentes terceiros molares humanos, tratados endodonticamente, um pino de fibra de vidro foi cimentado com um dos três cimentos resinosos. Cada raiz foi seccionada em sentido transversal para a obtenção de três fatias (dentina-pino) de 1 mm de espessura. As fatias, correspondentes aos terços cervical, médio e apical do canal radicular, foram armazenadas em água deionizada a 37 ºC, durante 24 horas ou 30 dias. Após o teste de push-out, os valores de resistência da união foram submetidos aos testes estatísticos ANOVA three way e Tuckey (p = 0,05) e os tipos de fratura foram avaliados através de microscopia eletrônica de varredura. A resistência da união do cimento resinoso auto-adesivo RelyX U100 foi superior à do cimento convencional RelyX ARC, após os dois períodos de armazenamento (p < 0,05). No terço cervical, os valores de resistência da união do cimento resinoso convencional RelyX ARC foram maiores que nos terços médio e apical (p < 0,05) na análise de 24 horas. Após 30 dias de armazenamento, os valores nos três terços radiculares não diferiram entre si. Os valores de resistência da união do cimento resinoso RelyX U100, nas três regiões do canal radicular, não diferiram entre si (p > 0,05), em ambos os momentos de avaliação. Após 24 horas, BisCem apresentou maior resistência da união no terço apical, seguido pelo terço cervical. Após 30 dias, os valores de resistência da união nos três terços radiculares não diferiram entre si (p > 0,05). RelyX U100 não sofreu alteração nos valores de resistência da união após 30 dias de envelhecimento (p > 0,05). BisCem não apresentou diferenças nos valores obtidos após 24 horas e 30 dias de envelhecimento nos terços cervical e médio (p > 0,05). Para RelyX ARC, o tempo de 30 dias reduziu os valores de resistência da união nos três terços radiculares. RelyX U100 e BisCem apresentaram maior número de falhas coesivas da zona de interação. Para RelyX ARC, observou-se maior número de falhas coesivas da camada híbrida. Concluiu-se que o cimento resinoso auto-adesivo RelyX U100 apresentou maior resistência da união que o cimento resinoso convencional RelyX ARC, nos três terços radiculares, nos dois momentos de avaliação. BisCem demonstrou resistência da união comparável a do cimento RelyX U100. O tempo de armazenamento por 30 dias provocou alteração na resistência da união dos cimentos resinosos RelyX ARC e BisCem. / This study evaluated the push-out bond strength of two self-adhesive resin cements and a conventional etch-and-rinse resin cement on root dentin. Sixty human third molars were endodontically treated and a glass fiber post was cemented with one of three resin cements. Each root was cut transversely to obtain three slices (dentin-post) of 1 mm thick. The slices of the cervical, middle and apical root canal were stored in deionized water at 37 °C for 24 hours or 30 days. After storage, the push-out test was performed. The values of bond strength were evaluated by ANOVA three way and Tuckey’ test (p = 0,05) and the types of fracture were evaluated by scanning electron microscopy. The bond strength of the self-adhesive resin cement RelyX U100 was superior to the RelyX ARC etch-and-rinse cement, after the two storage periods (p > 0.05). The analysis of 24 hours showed that at the cervical third, the values of bond strength of RelyX ARC were higher than that of the middle and apical thirds (p < 0.05). After 30 days of storage, the values at the three root thirds did not differ. The values of RelyX U100, on the three regions of the root canal did not differ, in both evaluations (p > 0.05). After 24 hours, BisCem showed higher bond strength at the apical third, followed by cervical. After 30 days, the values of bond strength at the three root thirds did not differ (p > 0.05). RelyX U100 did not exhibit changes in bond strength values after 30 days of storage (p > 0.05). BisCem showed no differences in the values obtained after 24 hours and 30 days of aging at the cervical and middle thirds (p > 0.05). The storage time of 30 days reduced the values of bond strength at the three root thirds of RelyX ARC. RelyX U100 e BisCem had the highest number of cohesive failures of the zone of interaction. RelyX ARC presented a higher number of cohesive failures of the hybrid layer were observed. It was concluded that the RelyX U100 self-adhesive resin cement showed higher bond strength than the conventional resin cement RelyX ARC, on the three root thirds, in both periods. BisCem showed bond strength comparable to RelyX U100. The storage time for 30 days caused changes on the bond strength of the RelyX ARC and BisCem resin cements.

Page generated in 0.0497 seconds