Spelling suggestions: "subject:"endosseous Dental implant"" "subject:"endosseous Dental emplant""
1 |
A comparative study to evaluate patient satisfaction with conventional dentures and implant retained overdentures.Al-Makki, Amjad January 2006 (has links)
<p><span style="font-size: 8pt / " text-align:="" font-family:="" color:="">The edentulous jaw is a common feature in elderly patients that had lost their teeth during life due to local reasons such as poor oral hygiene and dental caries as well as periodontal disease. Hence these patients are the victims of biological phenomenona that lead to difficulties in different aspects of patient comfort with dentures. Clinicians are always concerned to minimize these difficulties and increase patient comfort through manufacturing a proper prosthesis to substitute for the loss of the natural teeth as well as the surrounding structures for optimum satisfaction and improved quality of life of the patient. The aim of this study was to evaluate patient satisfaction regarding function and aesthetics with conventional mandibular dentures and implant retained mandibular overdentures in denture wearers.</span></p>
|
2 |
A comparative study to evaluate patient satisfaction with conventional dentures and implant retained overdentures.Al-Makki, Amjad January 2006 (has links)
<p><span style="font-size: 8pt / " text-align:="" font-family:="" color:="">The edentulous jaw is a common feature in elderly patients that had lost their teeth during life due to local reasons such as poor oral hygiene and dental caries as well as periodontal disease. Hence these patients are the victims of biological phenomenona that lead to difficulties in different aspects of patient comfort with dentures. Clinicians are always concerned to minimize these difficulties and increase patient comfort through manufacturing a proper prosthesis to substitute for the loss of the natural teeth as well as the surrounding structures for optimum satisfaction and improved quality of life of the patient. The aim of this study was to evaluate patient satisfaction regarding function and aesthetics with conventional mandibular dentures and implant retained mandibular overdentures in denture wearers.</span></p>
|
3 |
A comparative study to evaluate patient satisfaction with conventional dentures and implant retained overdenturesAl-Makki, Amjad January 2006 (has links)
Magister Scientiae Dentium - MSc(Dent) / The edentulous jaw is a common feature in elderly patients that had lost their teeth during life due to local reasons such as poor oral hygiene and dental caries as well as periodontal disease. Hence these patients are the victims of biological phenomenona that lead to difficulties in different aspects of patient comfort with dentures. Clinicians are always concerned to minimize these difficulties and increase patient comfort through manufacturing a proper prosthesis to substitute for the loss of the natural teeth as well as the surrounding structures for optimum satisfaction and improved quality of life of the patient. The aim of this study was to evaluate patient satisfaction regarding function and aesthetics with conventional mandibular dentures and implant retained mandibular overdentures in denture wearers. / South Africa
|
4 |
Avaliação do reparo ósseo de cavidades preenchidas por vidro bioativo ou osso liofilizado desmineralizado: análises biomecânica, microscópica e histométrica em cãesMendes, Vanessa Cristina [UNESP] January 2004 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:07Z (GMT). No. of bitstreams: 0
Previous issue date: 2004Bitstream added on 2014-06-13T18:41:42Z : No. of bitstreams: 1
mendes_vc_dr_araca.pdf: 2490243 bytes, checksum: 6ce7b53f4434b723ec9c25c37375666f (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Os objetivos do presente estudo foram analisar e comparar, em cães, a reparação óssea em defeitos preenchidos com vidro bioativo e osso desmineralizado liofilizado e comparar com áreas que não receberam biomateriais, antes e após a inserção de implantes dentários de titânio. Cavidades com 6mm de diâmetro foram realizadas em ambos os úmeros de 6 cães machos saudáveis e preenchidas com vidro bioativo, osso liofilizado desmineralizado e coágulo. Após 5 meses de reparação, foi removido tecido ósseo do centro das cavidades para análise de microscopia óptica. A seguir, implantes dentários de titânio foram colocados no centro dessas cavidades e em áreas de osso pré-existente. Três meses depois, realizou-se o teste biomecânico de contra-torque dos implantes. Os cães foram sacrificados e o tecido ósseo encaminhado para processamento e análise de microscopia eletrônica por retroespalhamento de elétrons. No teste biomecânico não foram observadas diferenças estatisticamente significantes entre os 4 grupos. A análise de microscopia óptica demonstrou a presença de ambos os biomateriais e tecido ósseo neoformado na maioria das amostras do grupo experimental. Na microscopia eletrônica por retro-espalhamento de elétrons observou-se neoformação óssea em todos os grupos. Pela análise histométrica, a quantidade de neoformação óssea no grupo do vidro bioativo foi estatisticamente maior em relação aos outros grupos. Concluiu-se que o vidro bioativo apresentou os melhores resultados em porcentagem de neoformação óssea. No entanto, uma reparação satisfatória foi demonstrada em todos os grupos, com adequada qualidade óssea ao redor dos implantes dentários. / The objectives of the present study were to analyze and compare, in dogs, the bone healing in large areas grafted with bioactive glass and DFDBA to areas without any grafting, before and after the insertion of titanium dental implants. Cavities (6mm diameter) were drilled in both humeri of 6 healthy male dogs. The cavities were filled in with bioactive glass, DFDBA and clot. After 5 months, bone was removed from the centre of the cavities and processed for light microscopy analysis. Titanium dental implants were placed in these sites and in areas not previously drilled. Three months later, a biomechanical test was performed and the force necessary to unscrew the titanium implants was measured. Dogs were sacrificed and the bone removed. After embedding in PMMA, calcified samples were cut in half and polished for back-scattering SEM analysis. No statistically significant differences were observed among the 4 groups concerning the biomechanical test, according to the test U of Mann- Whitney. Light microscopy analysis showed the presence of both biomaterials among the regenerated bone. In the back-scattering analysis, regenerated bone was seen in all groups, and DFDBA presented the least volume. Remnants of granules of bioactive glass were still present, but in a smaller size. Because granules of DFDBA have the same image density of bone, if present, they couldn’t be identified. According to the test U of Mann-Whitney, the amount of bone formation in the bioactive glass group was statistically higher compared to the other groups. Based on the findings of this study, it was concluded that the bioactive glass showed best results in terms of bone volume. However, a satisfactory regeneration of bone in large defects with adequate bone quality was observed around dental implants in all groups.
|
5 |
Avaliação do reparo ósseo de cavidades preenchidas por vidro bioativo ou osso liofilizado desmineralizado : análises biomecânica, microscópica e histométrica em cães /Mendes, Vanessa Cristina. January 2004 (has links)
Orientador: Paulo Sérgio Perri de Carvalho / Resumo: Os objetivos do presente estudo foram analisar e comparar, em cães, a reparação óssea em defeitos preenchidos com vidro bioativo e osso desmineralizado liofilizado e comparar com áreas que não receberam biomateriais, antes e após a inserção de implantes dentários de titânio. Cavidades com 6mm de diâmetro foram realizadas em ambos os úmeros de 6 cães machos saudáveis e preenchidas com vidro bioativo, osso liofilizado desmineralizado e coágulo. Após 5 meses de reparação, foi removido tecido ósseo do centro das cavidades para análise de microscopia óptica. A seguir, implantes dentários de titânio foram colocados no centro dessas cavidades e em áreas de osso pré-existente. Três meses depois, realizou-se o teste biomecânico de contra-torque dos implantes. Os cães foram sacrificados e o tecido ósseo encaminhado para processamento e análise de microscopia eletrônica por retroespalhamento de elétrons. No teste biomecânico não foram observadas diferenças estatisticamente significantes entre os 4 grupos. A análise de microscopia óptica demonstrou a presença de ambos os biomateriais e tecido ósseo neoformado na maioria das amostras do grupo experimental. Na microscopia eletrônica por retro-espalhamento de elétrons observou-se neoformação óssea em todos os grupos. Pela análise histométrica, a quantidade de neoformação óssea no grupo do vidro bioativo foi estatisticamente maior em relação aos outros grupos. Concluiu-se que o vidro bioativo apresentou os melhores resultados em porcentagem de neoformação óssea. No entanto, uma reparação satisfatória foi demonstrada em todos os grupos, com adequada qualidade óssea ao redor dos implantes dentários. / Abstract: The objectives of the present study were to analyze and compare, in dogs, the bone healing in large areas grafted with bioactive glass and DFDBA to areas without any grafting, before and after the insertion of titanium dental implants. Cavities (6mm diameter) were drilled in both humeri of 6 healthy male dogs. The cavities were filled in with bioactive glass, DFDBA and clot. After 5 months, bone was removed from the centre of the cavities and processed for light microscopy analysis. Titanium dental implants were placed in these sites and in areas not previously drilled. Three months later, a biomechanical test was performed and the force necessary to unscrew the titanium implants was measured. Dogs were sacrificed and the bone removed. After embedding in PMMA, calcified samples were cut in half and polished for back-scattering SEM analysis. No statistically significant differences were observed among the 4 groups concerning the biomechanical test, according to the test U of Mann- Whitney. Light microscopy analysis showed the presence of both biomaterials among the regenerated bone. In the back-scattering analysis, regenerated bone was seen in all groups, and DFDBA presented the least volume. Remnants of granules of bioactive glass were still present, but in a smaller size. Because granules of DFDBA have the same image density of bone, if present, they couldn't be identified. According to the test U of Mann-Whitney, the amount of bone formation in the bioactive glass group was statistically higher compared to the other groups. Based on the findings of this study, it was concluded that the bioactive glass showed best results in terms of bone volume. However, a satisfactory regeneration of bone in large defects with adequate bone quality was observed around dental implants in all groups. / Doutor
|
6 |
Estudo sobre o comportamento biomecânico de implantes curtos com variação da espessura da cortical óssea por meio do método dos elementos finitos / Biomechanical behavior of short implants varying thickness of cortical bone by finite element methodConde Neto, José Augusto 01 October 2012 (has links)
Este estudo teve como objetivo analisar e comparar o comportamento biomecânico de um implante de comprimento curto com um implante de comprimento padrão, no que diz respeito às tensões ósseas ao redor do implante. Foi considerado como variável o aumento da espessura óssea cortical, em dois tipos: fino e espesso. Os modelos de elementos finitos em três dimensões (3D) foram criados a partir de uma secção de mandíbula de 20 mm, referente ao segundo pré-molar, com um implante endósseo único inserido dentro do osso esponjoso com cortical fina de 0,5 mm e cortical espessa de 2,0 mm. Uma carga oclusal vertical de 100 N e uma carga oblíqua de 40 N foram aplicadas. Os ossos cortical e esponjoso foram considerados isotrópicos e linearmente elásticos e o critério de avaliação foi o de tensões de von Mises. O implante curto utilizado foi de 4,1 mm de diâmetro por 6,0 mm de comprimento, e o implante padrão de 4,1 mm de diâmetro por 10,0 mm de comprimento (ambos da marca Straumann®). A prótese sobre o implante foi composta por um pilar sólido de 5,5 mm de altura e por uma coroa de segundo pré-molar. Conforme as simulações pelo MEF, pôde-se concluir que: 1) O aumento da espessura óssea favoreceu uma melhor distribuição das tensões, registrando valores mais baixos na região cervical cortical. 2) O modelo de implante curto na situação de cortical espessa apresentou melhores resultados biomecânicos comparado com o modelo de implante padrão na situação de cortical fina. / The aim of this monograph was to analyze and compare the biomechanical behavior of a short length implant against a standard length implant, regarding stress distribution on the bone around the implant. Bone cortical thickness of the ridge was considered as thin and thick. The 3D finite element models were created of a 20-mm second premolar section of the mandible with a single endosseous implant embedded in cancellous bone with thin cortical of 0.5 mm and with thick cortical of 2.0 mm. A vertical occlusal load of 100 N and an oblique load of 40 N were applied. The cortical and cancellous bone were considered to be isotropic and linearly elastic Von Mises stress criterion was used for analysis. The short implant used was of 4.1 mm of diameter and 6 mm in length, and the standard implant was of 4.1 mm of diameter and 10 mm in length (both Straumann ®). The prosthesis on the implant consisted of a solid abutment of 5.5 mm in height and a crown of second premolar. Conclusions: 1) Increasing bone thickness favored a better stress distribution, showing lower values in the cervical cortical bone. 2) Short implants with thin cortical situations showed better biomechanical results compared to standard implants with thick cortical situations.
|
7 |
Estudo sobre o comportamento biomecânico de implantes curtos com variação da espessura da cortical óssea por meio do método dos elementos finitos / Biomechanical behavior of short implants varying thickness of cortical bone by finite element methodJosé Augusto Conde Neto 01 October 2012 (has links)
Este estudo teve como objetivo analisar e comparar o comportamento biomecânico de um implante de comprimento curto com um implante de comprimento padrão, no que diz respeito às tensões ósseas ao redor do implante. Foi considerado como variável o aumento da espessura óssea cortical, em dois tipos: fino e espesso. Os modelos de elementos finitos em três dimensões (3D) foram criados a partir de uma secção de mandíbula de 20 mm, referente ao segundo pré-molar, com um implante endósseo único inserido dentro do osso esponjoso com cortical fina de 0,5 mm e cortical espessa de 2,0 mm. Uma carga oclusal vertical de 100 N e uma carga oblíqua de 40 N foram aplicadas. Os ossos cortical e esponjoso foram considerados isotrópicos e linearmente elásticos e o critério de avaliação foi o de tensões de von Mises. O implante curto utilizado foi de 4,1 mm de diâmetro por 6,0 mm de comprimento, e o implante padrão de 4,1 mm de diâmetro por 10,0 mm de comprimento (ambos da marca Straumann®). A prótese sobre o implante foi composta por um pilar sólido de 5,5 mm de altura e por uma coroa de segundo pré-molar. Conforme as simulações pelo MEF, pôde-se concluir que: 1) O aumento da espessura óssea favoreceu uma melhor distribuição das tensões, registrando valores mais baixos na região cervical cortical. 2) O modelo de implante curto na situação de cortical espessa apresentou melhores resultados biomecânicos comparado com o modelo de implante padrão na situação de cortical fina. / The aim of this monograph was to analyze and compare the biomechanical behavior of a short length implant against a standard length implant, regarding stress distribution on the bone around the implant. Bone cortical thickness of the ridge was considered as thin and thick. The 3D finite element models were created of a 20-mm second premolar section of the mandible with a single endosseous implant embedded in cancellous bone with thin cortical of 0.5 mm and with thick cortical of 2.0 mm. A vertical occlusal load of 100 N and an oblique load of 40 N were applied. The cortical and cancellous bone were considered to be isotropic and linearly elastic Von Mises stress criterion was used for analysis. The short implant used was of 4.1 mm of diameter and 6 mm in length, and the standard implant was of 4.1 mm of diameter and 10 mm in length (both Straumann ®). The prosthesis on the implant consisted of a solid abutment of 5.5 mm in height and a crown of second premolar. Conclusions: 1) Increasing bone thickness favored a better stress distribution, showing lower values in the cervical cortical bone. 2) Short implants with thin cortical situations showed better biomechanical results compared to standard implants with thick cortical situations.
|
Page generated in 0.0669 seconds