• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 40
  • 1
  • Tagged with
  • 42
  • 42
  • 42
  • 17
  • 17
  • 17
  • 12
  • 10
  • 9
  • 7
  • 7
  • 6
  • 6
  • 6
  • 5
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Avaliação do potencial de conservação de energia no setor hospitalar da região sul do Brasil

Silveira, Alexandre Hugo da January 2008 (has links)
Made available in DSpace on 2013-08-07T18:53:39Z (GMT). No. of bitstreams: 1 000401161-Texto+Completo-0.pdf: 3203510 bytes, checksum: 5f982969daeb4904827ef17bc67ef11c (MD5) Previous issue date: 2008 / This study aimed to assess the potential for energy saving in the Hospital Sector in the South Region of Brazil and its impact on the mitigation of carbon dioxide emission to the atmosphere, achieved through the reduction in the consumption of electricity. The study analyzed sixteen hospitals where energy saving projects has been implemented. Each hospital has been monitored before and after the implementation of energy saving projects through energy audits conducted by the Research Group on Energy Efficiency from PUCRS. Moreover, the study used data from the IBGE and DATASUS. The estimation of energy saving and other values of interest was carried out according to methodologies based on population statistics. As the first step, it was calculated the mean values of consumption and demand before energy efficiency projects, reductions in consumption and demand after energy efficiency projects, and the necessary financial investments. All relevant data have been normalized using the number of available beds on each hospital. As a second step, through the calculation of the linear regression, it was found the estimated consumption of each of the hospitals in the South Region of Brazil. Summing up the individual data, it was possible to obtain the values for the whole population, which was in the sequence compared to the mean values in order to verify its coherence. As a result, for the whole population, it was found an annual consumption of 548 GWh of energy and a power demand of 112 MW, which could be achieved with projects aiming to improve the efficiency of the use of electrical energy. It was also found that such projects could lead to a reduction of 171. 54 GWh on the energy consumption and 43. 5 MW of power demand. However, this would also require an investment of R$ 157. 08 million. Taking into account the avoided costs for the expansion of the electrical system to meet the same power demand, this investment would be paid in 3. 6 years. Concerning environmental impacts, such energy conservation actions would allows avoiding the emission of 164 thousand tones of CO2 per year. Finally, this study shows the great importance of energy saving in the hospital sector and the benefits that actions of energy conservation would have to the society. / Este trabalho teve como objetivo avaliar o potencial de economia de energia no Setor Hospitalar da Região Sul do Brasil, bem como os impactos quanto à mitigação de dióxido de carbono na atmosfera, alcançados através das reduções no consumo de eletricidade. Para tanto a pesquisa contou com dezesseis hospitais, cada qual com seu diagnóstico energético elaborado pelo Grupo de Eficiência Energética da PUCRS. Além disso, o trabalho utilizou dados do DATASUS e do IBGE. Os cálculos para a estimação dos valores populacionais seguiram metodologias baseadas na estatística, onde, primeiramente, calcularam-se as médias aritméticas de: consumo e demanda antes de projetos de eficiência energética, reduções de consumo e demanda após as ações de eficiência energética e investimento, todos relacionados com o número de leitos disponível à internação. Posteriormente, através do cálculo da regressão linear, foi encontrado o consumo estimado de cada um dos hospitais da Região Sul do país e, somados os dados individuais, obtiveram-se os valores para a população. Estes valores foram comparados com os encontrados por meio da média a fim de se verificar a pertinência dos mesmos. Como resultados, encontrou-se para a população um consumo anual de 548 GWh e uma demanda de energia de 112 MW, onde, realizando ações de eficiência energética alcança-se uma redução de 171,5 GWh de consumo e 43,5 MW de demanda, necessitando-se de um investimento de R$ 157,08 milhões. Levando em conta os custos evitados para a ampliação do sistema elétrico no intuito de atender a mesma demanda, este investimento seria pago em 3,6 anos. No que tange aos impactos ambientais, com tais ações de conservação de energia, evita-se a emissão de 164 mil toneladas de CO2 por ano. Assim, este trabalho mostra a grande importância de se combater o desperdício de energia elétrica no setor e os benefícios que as ações de conservação de energia trariam para a sociedade.
22

Gerenciamento da demanda residencial de eletricidade : o caso de centros urbanos da Região Amazonica

Pompermayer, Maximo Luiz 29 March 2000 (has links)
Orientador: Glberto De Martino Jannuzzi / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-07-26T12:23:42Z (GMT). No. of bitstreams: 1 Pompermayer_MaximoLuiz_D.pdf: 24581115 bytes, checksum: c817996986fc4bb2ea4ed357c83f8ef4 (MD5) Previous issue date: 2000 / Resumo: O primeiro choque do petróleo - março de 1973 - marcou o início de uma nova era da economia mundial. O modelo tradicional de planejamento energético foi colocado em xeque e o desacoplamento entre consumo de energia e crescimento econômico passou a ser tema de numerosos estudos. Neste contexto, o Gerenciamento pelo Lado da Demanda (GLD) passou a ser um instrumento importante de planejamento, para muitas companhias de eletricidade. Aliado a políticas de proteção ao meio ambiente, o GLD tem sido um instrumento eficaz contra o uso ineficiente e irracional de energia. Neste trabalho, analisa-se o caso de centros urbanos da Região Amazônica, os quais têm apresentado sérios problemas de suprimento de eletricidade. Através da aplicação de questionários a uma amostra de consumidores residenciais, levantou-se o grau de difusão, a tipologia e os hábitos de uso dos aparelhos. Após análise estatística das relações entre o perfil sócio-econômico do consumidor e os referidos indicadores, elaborou-se a estrutura de uso final, tanto em termos de energia consumida quanto de carga requerida. Comparou-se, então, o desempenho energético dos aparelhos em uso com o de aparelhos equivalentes, energeticamente eficientes e comercialmente disponíveis. Os resultados revelam que seria possível e altamente rentável, tanto para o consumidor quanto para os demais atores envolvidos, reduzir gradualmente o consumo, através da aquisição de tecnologias eficientes. Considerando apenas os aparelhos cuja substituição proporcione ao consumidor um retomo maior ou igual a 200,10 ao ano, seria possível, em cinco anos, reduzir 13,6% o consumo e 15,4% a demanda máxima residencial. Os impactos aumentam ao longo do tempo, à medida que o parque de aparelhos se renova. Após reposição de todo o parque atual, estima-se que as economias alcançariam 22% / Abstract: The first oil crisis in 1973 marks the beginning of a new era in the intemational economy. One of the outcomes was the decoupling effect noted between economic growth and energy demand, forcing a revision of traditional models of energy planning. In the context, the Demand Side Management (DSM) became a very important planning instrument for many electricity companies. With the support of the environment policies, DSM became an effective instrument for the improvement of the efficient use of energy. This study analyses the case of urban centers (Manaus, Macapá and Porto Velho) of the Amazon Region, which present serlous problems for the continuing supply of their electricity service. Household appliance ownership and uses were characterized by means of a survey. Further analysis was developed associating socio-economic protiles and several energy indicators, and a detailed end use energy demand structure was elaborated. In this work we also compare the energy performance of the several household appliances and discuss the available commercial economic potential for energy conservation. We show that there is a significant potential for introducing more efficient technologies yielding economic benefits to consumers and utilities. Considering only investment opportunities in more efficient appliances that yield a 20% internal rate of retum per year, it would be possible, in tive years, to lower 13.6% the consumption and 15.4% the residential peak load. These impacts increase over time, as the stock of appliances is renewed. After complete reposition of the stock, one estimates that the savings would attain 22% / Doutorado / Doutor em Planejamento de Sistemas Energéticos
23

Mecanismos regulatorios, tarifarios e economicos na geração distribuida : o caso dos sistemas fotovoltaticos conectados a rede

Cervantes Rodriguez, Carlos Roberto 19 July 2002 (has links)
Orientador: Gilberto De Martino Jannuzzi / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-08-02T03:29:04Z (GMT). No. of bitstreams: 1 CervantesRodriguez_CarlosRoberto_M.pdf: 8714025 bytes, checksum: 943ae13973c87901d436ff1d58b81755 (MD5) Previous issue date: 2002 / Resumo: Ao longo das últimas três décadas, a tecnologia solar fotovoltaica tem experimentado uma redução substancial dos seus custos de produção, verificando-se um fator de aprendizado de 20% a cada vez que as vendas se duplicavam. No entanto, o custo da energia fotogerada apresenta-se competitivo unicamente em aplicações isoladas, pois, por um lado, para aplicações conectadas à rede, a geração centralizada através de plantas que consomem combustíveis fósseis apresenta menores custos de eletricidade. Por outro lado, o mercado e a indústria fotovoltaica ainda estão em uma fase prematura tornando-se dificil capturar as economias de escala. Nesse sentido, em um esforço por estimular o mercado fotovoltaico, numerosos governos têm agido na formulação de políticas públicas específicas que incluem a adoção de tarifas favoráveis, tais como net metering e feed-in, e a concessão de subsídios ao investimento inicial. O objetivo deste trabalho é avaliar e discutir a influência dos distintos tipos de incentivos na viabilidade econômica dos sistemas fotovoltaicos conectados à rede. Os resultados mostram que as tarifas tipo feed-in são mais apropriadas para fomentar a disseminação deste tipo de instalações, pois as tarifas baseadas em net metering precisam necessariamente do auxílio de subsídios de capital para tornar viável o investimento para o consumidor. Do lado da concessionária, o impacto dos programas tarifários não é tão grande caso seja estabelecido um teto para a capacidade total instalada dos sistemas / Abstract: Over the past three decades, the solar photovoltaic technology have experienced substantial price reductions, with a learning rate of 20% for each doubling of sales. Nevertheless, photovoltaic electricity cost is competitive only in off-grid applications, because in the case of on-grid applications those available from centralized fossil fuel plants has lower electricity costs. On the other hand, the high prices of photovoltaic electricity are caused by the relative immaturity of its industry and products, and hence the economy of scale. In this way, a number of governments are acting in favor of the formulation of specific public policies in order to stimulate the growth of the photovoltaic market. These instruments include favorable tariffs such as net metering and feed-in tariffs and capital cost subsidies. The aim of this work is to evaluate and discuss the different types of incentives and its influence on the economic feasibility on grid connected photovoltaic power systems. The results show that feed-in tariffs type are more proper to encourage the dissemination of these type of installations, because tariffs in net metering basis require the support of capital cost subsidies, in order to make feasible the investment for the consumer. From the utility side, the impact of such programs is not so big, since in the case of a set up limit for the total capacity instal1ed of the systems / Mestrado / Mestre em Engenharia Mecânica
24

Analise do consumo de energia e perspectivas da demanda residencial de eletricidade em Rondonia

Cursino, Edmilson Antonio 23 July 2018 (has links)
Orientador: Gilberto De Martino Jannuzzi / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-07-23T20:29:51Z (GMT). No. of bitstreams: 1 Cursino_EdmilsonAntonio_M.pdf: 7735068 bytes, checksum: 0dc6c42b8235bbab88175ccca233aa34 (MD5) Previous issue date: 1998 / Resumo: No presente trabalho procurou-se analisar o consumo de energia e projetar a demanda residencial de eletricidade para um horizonte de dez anos, utilizando dois diferentes cenários: um tendencial e outro eficiente. Para isto é necessário conhecer o histórico e a estrutura de consumo de energia no Estado, principalmente as informações do cenário de referência. Utilizou-se uma metodologia específica para a elaboração do balanço dos principais energéticos: eletricidade e derivados de petróleo, bem como a série histórica do consumo de energia no período 1986 a 1995. Utilizaram-se também os resultados de uma pesquisa de campo na metodologia de Planejamento Integrado de Recursos, para desagregar o consumo residencial de eletricidade por usos finais para o ano base, e projetar sua demanda para o ano 2005. Obtidos os dados históricos, analisou-se o consumo de energia. No setor residencial, desagregou-se o consumo de eletricidade por usos finais. Os resultados das projeções da demanda residencial de eletricidade por usos finais apontaram os equipamentos que mais demandam energia. Os resultados deste trabalho são muito relevantes na definição de políticas de racionalização do uso de eletricidade e ações de gerenciamento do lado da demanda / Abstract: The objective of this study was given to energy consumption as well as residential demand of electricity for a tem year planning horizon, by using two different scenarios. For this purpose, the history and the energy consumption structure are needed, as well as principally, the reference scenario information. Specific methodology was used in making the balance of the principal energetic sources: electricity and petroleum-derived products, as well as the energy consumption historical series during 1986 to 1995. The results of a field research according to the Integrated Planning of Resources methodology, were also applied to disaggregated the residential electricity consumption by final uses, for the base-year, and so to project its demand at 2005. Historical data obtained, energy consumption was analyzed. In residential sector domain, electricity consumption was disaggregate by final uses. The projections results of the residential electricity demand by final uses the most energy demanding equipments. The results of this study-research are surely very important in the definition of electricity rational use politics, and demand side management actions / Mestrado / Mestre em Planejamento de Sistemas Energéticos
25

A postura empresarial de empresas energeticas diante de novos negocios : CESP um estudo de caso

Prado Júnior, Fernando Amaral de Almeida 20 December 1994 (has links)
Orientador: Carlos Alberto Mariotoni / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-07-20T01:34:07Z (GMT). No. of bitstreams: 1 PradoJunior_FernandoAmaraldeAlmeida_M.pdf: 27680769 bytes, checksum: b35489a9398c8761c60b48d53f6d2e48 (MD5) Previous issue date: 1994 / Resumo: Não informado / Abstract: Not informed. / Mestrado / Mestre em Engenharia Mecânica
26

Padrões de investimentos das empresas de eletricidade em programas de pesquisa e desenvolvimento tecnologico e em eficiencia energetica / One assessment of investments from electricity utilities on research and technological development and energy efficiency programs on the period between 2002-2004

Santos, Herivelto Tiago Marcondes dos 18 October 2006 (has links)
Orientador: Gilberto De Martino Jannuzzi / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-08-09T12:30:01Z (GMT). No. of bitstreams: 1 Santos_HeriveltoTiagoMarcondesdos_M.pdf: 831089 bytes, checksum: 0c9db7d62f8e506686cc6b9059f1eb4f (MD5) Previous issue date: 2006 / Resumo: Este trabalho apresenta uma avaliação dos investimentos feitos pelas empresas brasileiras de eletricidade em programas de P&D e em eficiência energética, segundo a imposição da lei federal 9.991/00. Conforme esta lei, as empresas de eletricidade são obrigadas a investirem nesses programas, no mínimo, 1% de suas receitas operacionais líquidas anuais. Com isso, essas empresas foram avaliadas segundo as suas participações no mercado de eletricidade sobre os investimentos em tipos de projetos (eficiência energética) ou tópicos tecnológicos (P&D). A avaliação foi feita usando um índice de concentração de mercado e, nesse caso, utilizou-se o índice Herfindahl ¿ Hirschman, como também por meio de estatísticas descritivas dos programas desenvolvidos. Como parte das conclusões observou-se que as empresas de eletricidade apresentaram alguns padrões de investimentos os quais podem ser utilizados como referência aos futuros programas de P&D e de eficiência energética / Abstract: This work presents one assessment of investments to carry out on research and technological development (R&D) and energy efficiency programs according to impose of federal act 9.991/00. It is to determine that the electricity utilities to invest 1% of annual utilities revenues on those programs. Thus electricity utilities were evaluated according to its market quota on the investments in project type (energy efficiency) or technological topic (R&D). The assessment was realized through of concentration market index and it was utilized the Herfindahl ¿ Hirschman index and the Descriptives Statistics of programs. As part of conclusions was to verify that electricity utilities is to present some investment standard that to be reference to the futures programs in R&D and energy efficiency / Mestrado / Mestre em Planejamento de Sistemas Energéticos
27

Conservação de energia em edificios comerciais atraves da implementação de dispositivos de automação / Conservation of energy in commercial buildngs through the implementation of automation devices

Gomazako, Marcone Susumo 23 October 2007 (has links)
Orientador: Carlos Alberto Mariotoni / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-09T15:15:44Z (GMT). No. of bitstreams: 1 Gomazako_MarconeSusumo_D.pdf: 5293277 bytes, checksum: 54ecece1926586b33b8eb4664a564549 (MD5) Previous issue date: 2007 / Resumo: Este trabalho vem apresentar um panorama do sistema elétrico geralmente encontrado em construções comerciais de grande porte, com cerca de trinta anos de funcionamento, que operam de forma pouco eficiente para os parâmetros atuais, principalmente no seu sistema de ar condicionado central. Nessa construção (estudo), seu sistema de condicionamento ambiental representa um acréscimo na demanda energética de cerca de 60%, passando de 450.000 kWh/mês para 750.000 kWh/mês, e a troca desses equipamentos por mais modernos e eficientes, significaria grandes investimentos, tornando-se inviável no curto prazo. Com isso, elaborou-se um protótipo contendo dispositivos de automação, que podem ser incorporados ao sistema existente, sem grandes dificuldades, e minimizando os custos operacionais com o sistema. Esses dispositivos permitem um monitoramento mais eficiente, sem a necessidade desses investimentos, como a substituição de grandes equipamentos (compressores, chillers, etc.) que fazem parte do sistema de ar condicionado central. Esse protótipo permitiu demonstrar que com a aplicação desses dispositivos incorporados nesses sistemas, podem gerar uma economia de cerca de 20% no consumo de energia elétrica, que representa uma economia bastante significativa de 60.000 kWh/mês (neste caso) quando operado o sistema de ar condicionado, além de aliviar os recursos humanos disponibilizados para esse tipo de monitoramento / Abstract: This work comes to present a panorama of the electric system found usually in commercial constructions of great load, with about thirty years of operation, that operate in way a little efficient for the current parameters, mainly in her air conditioning system. In that construction (in study), her system of environmental conditioning represents an increment in the energy demand of about 60%, passing to the 450.000 kWh/month for 750.000 kWh/month, and the change of those equipments for more modern and efficient, it would mean great investments, becoming unviable in the short period. With that, a prototype was elaborated containing automation devices, that can be incorporate to the existent system, without great difficulties, and minimizing the operational costs with the system. Those devices allow a more efficient monitoring, without the need of those investments, as the substitution of great equipments (compressors, chillers, etc.) that they part of the system of air conditioned central. That prototype allowed to demonstrate that with the application of those incorporate devices in those systems, they can generate an economy of about 20% in the electric power consumption, that represents a quite significant economy of 60.000 kWh/month, (this case) when operated the system of conditioned air, besides relieving the human resources made available for that monitoring type / Doutorado / Recursos Hidricos, Energeticos e Ambientais / Mestre em Engenharia Civil
28

Analise de viabilidade de troca de motores eletricos superdimensionados e a influencia da energia reativa / Analysis of feasibility of the change of super dimensioned electrical engines and the influence of reactive energy

Castro, Renato Archanjo de 12 August 2018 (has links)
Orientador: Moacyr Trindade de Oliveira Andrade / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-08-12T05:28:32Z (GMT). No. of bitstreams: 1 Castro_RenatoArchanjode_M.pdf: 2548594 bytes, checksum: 5b0406363500b5419ff9f888bb2dac98 (MD5) Previous issue date: 2008 / Resumo: Este trabalho mostra a importância do motor elétrico de indução trifásico rotor gaiola de esquilo, que é o principal responsável pelo consumo de energia elétrica no seguimento industrial, apresenta suas características elétricas, mecânicas e sua evolução ao longo dos anos. Relata ainda a problemática do superdimensionamento destes motores instalados na indústria brasileira, ao qual tem como principal inconveniente a alta requisição de energia reativa nas instalações elétricas, apresenta a forma de faturamento da energia reativa aplicada pelas concessionárias de energia, bem como as principais formas de sua compensação aplicadas atualmente pela indústria nacional e seus efeitos na instalação existente. O trabalho apresenta uma análise comparativa entre o motor Alto Rendimento e o motor Standard, com ênfase na adequação da potência nominal em relação à demanda industrial, bem como em relação ao consumo de energia reativa das opções avaliadas. O suporte proveniente de pesquisas e adequações de instalações industriais aplicada pelo autor, em empresas da região de Americana, em relação à energia elétrica reativa, se constituem como base para o desenvolvimento deste trabalho. A conclusão final busca demonstrar que estas ações de conservação e adequação em motores elétricos industriais, são fundamentais para o processo de eficientização das próprias indústrias, do setor elétrico e da economia do país, de forma geral, uma vez que as mesmas implicam na redução da energia requerida pela indústria sem prover restrições a produção, resultando em significativa economia de recursos no provimento de novas fontes de energia e de melhor utilização do sistema elétrico nacional. / Abstract: This study shows the importance of the electrical engine of triphasic induction rotor (squirrel cage), which is the main responsible for the waste of electrical energy in industry; it presents its electrical and mechanical characteristics and its evolution along the years, as well. The study describes the problem of the super dimensioning of these engines that exist at the Brazilian industry, which has the major inconvenience of the high required of reactive energy in the electrical systems, presenting the way of invoicing the reactive energy applied by the power suppliers, as well as the main ways of its compensation applied presently by the national industry and its consequences for the existent installation. The study presents a comparative analysis between the engine of high efficiency and the Standard engine, focusing the adaptation of nominal power in relation to the industrial demand, as well as in what concerns the waste of reactive energy by the evaluated options. The background for the development of this study came from researches and adaptation of industrial plants applied by the Author in companies of the American region, as far as reactive electrical energy is concerned. The final conclusion tries to demonstrate that these actions of conservation and adaptation in industrial electrical engines are fundamental for the process of improving the efficiency of the very same industries, the electrical sector and the economy of the country as a whole, since that the same actions imply the reduction of the energy required by the industry without restrictions to the production, resulting into a significant saving of resources in what concerns the supply of new sources of energy and a better utilization of the national electrical system. / Mestrado / Mestre em Planejamento de Sistemas Energéticos
29

A contribuição da conservação de energia elétrica em instalações residenciais e seu impacto no planejamento da expansão da geração futura, com base na análise do Programa de Eficiência Energética - PEE desenvolvidas pelas concessionárias de energia elétrica no Brasil. / The contribution of the conservation of electric energy in residential installations and its impact in the planning of the expansion of the future generation, based on the analysis of the Energy Efficiency Program - PEE developed by the electric power concessionaires in Brazil.

Santos, Rodolfo Esmarady Rocha dos 20 August 2018 (has links)
Submitted by RODOLFO ESMARADY ROCHA DOS SANTOS (esmarady@yahoo.com.br) on 2018-09-13T14:59:07Z No. of bitstreams: 1 Tese_Rodolfo Esmarady Rocha dos Santos.pdf: 4337307 bytes, checksum: 1ff22a01eebe75138eb15230f51aa481 (MD5) / Rejected by Pamella Benevides Gonçalves null (pamella@feg.unesp.br), reason: Solicitamos que realize correções na submissão seguindo as orientações abaixo • De acordo com a contagem das páginas seu trabalho deve com o número (21), após você precisa atualizar a numeração na ficha catalográfica, nas listas e no sumário. • As palavras-chave e keyword devem ser separadas entre si por ponto final e também finalizadas por ponto. (favor ver exemplo no template ou diretrizes) • Referências. A palavra Referências deve ser centralizada, e não conter numeração de seção; As referencias devem ser justificadas, espaço simples com um espaço simples(enter) entre elas. • Sobre a elaboração das referencias e citações favor solicitar ajuda com a bibliotecária Juciene (juciene@feg.unesp.br) Mais informações acesse o link: http://www2.feg.unesp.br/Home/Biblioteca21/diretrizes-2016.pdf Agradecemos a compreensão. on 2018-09-13T17:47:09Z (GMT) / Submitted by RODOLFO ESMARADY ROCHA DOS SANTOS (esmarady@yahoo.com.br) on 2018-09-14T18:39:56Z No. of bitstreams: 1 Tese final_Rodolfo Esmarady Rocha dos Santos.pdf: 4339037 bytes, checksum: 1fe49e11c895d0d0fbeb9a2fd39824cf (MD5) / Rejected by Pamella Benevides Gonçalves null (pamella@feg.unesp.br), reason: Solicitamos que realize correções na submissão seguindo as orientações abaixo: É necessário rever suas referências, para tanto entre em contato com a bibliotecária Juciene (juciene.pedroso@unesp.br) para devidas correções Mais informações acesse o link: http://www2.feg.unesp.br/Home/Biblioteca21/diretrizes-2016.pdf Agradecemos a compreensão. . on 2018-09-14T20:02:42Z (GMT) / Submitted by RODOLFO ESMARADY ROCHA DOS SANTOS (esmarady@yahoo.com.br) on 2018-09-15T01:26:06Z No. of bitstreams: 1 Tese_versão_f_Rodolfo Esmarady Rocha dos Santos.pdf: 4937602 bytes, checksum: d89a0e5cbb78c7f5a03c1c73a13d9155 (MD5) / Rejected by Pamella Benevides Gonçalves null (pamella@feg.unesp.br), reason: Solicitamos que realize correções na submissão seguindo as orientações abaixo: É necessário rever suas referências, para tanto entre em contato com a bibliotecária Juciene (juciene.pedroso@unesp.br) para devidas correções. Neste sentido, você deve enviar o arquivo de sua dissertação em que constam as referências para que ela possa te indicar o que deve corrigir de acordo com as normas da ABNT 6023 e ou agendar para tirar dúvidas pessoalmente com ela. Agradecemos a compreensão. on 2018-09-17T14:54:26Z (GMT) / Submitted by RODOLFO ESMARADY ROCHA DOS SANTOS (esmarady@yahoo.com.br) on 2018-09-19T17:47:39Z No. of bitstreams: 1 Tese final_Rodolfo E R Santos.pdf: 4331564 bytes, checksum: dfd13fc66380afb68b3599c4528a5e4d (MD5) / Approved for entry into archive by Pamella Benevides Gonçalves null (pamella@feg.unesp.br) on 2018-09-20T14:43:30Z (GMT) No. of bitstreams: 1 santos_rer_dr_guara.pdf: 4331564 bytes, checksum: dfd13fc66380afb68b3599c4528a5e4d (MD5) / Made available in DSpace on 2018-09-20T14:43:30Z (GMT). No. of bitstreams: 1 santos_rer_dr_guara.pdf: 4331564 bytes, checksum: dfd13fc66380afb68b3599c4528a5e4d (MD5) Previous issue date: 2018-08-20 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O Programa de Eficiência Energética (PEE) das distribuidoras de energia elétrica é, atualmente, o principal mecanismo de destinação de recursos para a promoção do uso racional de energia no Brasil. Ao longo do período de 2000 a 2017, este instrumento proporcionou importantes alterações, como a implementação da Lei nº 12.212/2010, que determinou a aplicação da maior parcela dos recursos aos projetos de iluminação, troca de refrigeradores, reforma das instalações elétricas e aquecedores destinados a população de baixa renda. Neste contexto, para este estudo, foi desenvolvido um Software de Análise PEE responsável pela seleção das informações dos relatórios propostos e realizados do PEE, disponibilizado pela Agência Nacional de Energia Elétrica (ANEEL), possibilitando o acesso às informações relevantes contidas nos projetos. Em posse desses dados, foi possível determinar a economia de energia total de 3.190,12 GWh e redução de demanda na ponta de 1.168,05 MW para o período de análise abordado de 2009 a 2015, para os usos finais em iluminação e refrigeração. Na sequência do estudo, foi realizada uma avaliação sobre o impacto ambiental relacionado à redução de emissão de CO2, com a aplicação da metodologia proposta para o PEE da ANEEL, e pode-se verificar que foi evitada a emissão total de 1.244.457,02 tCO2 para o uso final em iluminação e 169.570,05 tCO2 para refrigeração (refrigerador), totalizando 1.414.027,07 tCO2 ao longo do período de 2009 a 2015. O foco principal desse estudo foi o desenvolvimento das novas Relações Custo-benefício (RCB) onde obteve-se para o uso final em iluminação uma RCB entre (0,10 a 0,18) para os cálculos tradicionais e RCB entre 0,08 a 0,17 adotando as Reduções Certificadas de Emissões (RCE) calculadas com a redução do CO2, demostrando que ambos resultados ficaram inferior ao máximo estabelecido pela ANEEL, proporcionando assim uma contribuição significativa para os demais projetos do PEE. Para o uso final em refrigeração os resultados apresentaram uma RCB tradicional entre 0,97 a 1,62 e, incrementando as RCEs, o resultado apresentou as RCBs entre 0,97 a 1,60. No caso do uso final em refrigeração ambos resultados superam o máximo estabelecido pela ANEEL, demostrando que a utilização deste uso final, isoladamente, não é viável para os projetos do PEE. E, por fim, foi possível desenvolver uma Usina Virtual Equivalente (UVE), adotando os custos reais médios das construções das Usinas Hidrelétricas (UHE) e de Pequenas Centrais Hidrelétricas (PCHs), e obtendo-se uma UVE de 77,27 MW de potência total, para os projetos analisados. No entanto, apesar das discussões ao redor desta temática, os projetos do PEE promovem melhorias relacionadas à demanda de energia e economia de energia elétrica para os consumidores dos usos finais abordados. Desse modo, foi de extrema importância acompanhar o desempenho energético destes projetos, nos quais foram identificados fatores que podem potencializar os resultados, de acordo com a região onde serão aplicados. Além disso, a economia de energia poderá contribuir com a Empresa de Planejamento Energético (EPE), que vem desenvolvendo trabalhos para incluir nos Planos Decenais de Expansão de Energia (PDE 2026) tais resultados, provenientes das ações de eficiência energética. / The Energy Efficiency Program (PEE) of energy distributors is currently the main mechanism for allocating resources for the advancement of rational energy use in Brazil. Over the period from 2000 to 2017, this tool has undergone important changes, such as the implementation of Law 12,212 / 2010, which has determined the application of most of the resources to lighting projects, fridge replacement, electrical and heaters installation aimed at a low-income population. In this context, a PEE Analysis Software was developed for this study, which was used to select information from PEE proposed and performed reports, provided by the National Electric Energy Agency (ANEEL), allowing access to the relevant information contained in the projects. Based on these data, it was possible to determine a total energy saving of 3,190.12 GWh and demand reduction at peak of 1,168.05 MW for the analysis period from 2009 to 2015. Following the study, it was conducted an assessment on the environmental impact related to CO2 emission reduction, with the application of the methodology proposed for the ANEEL PEE, and it can be verified a total emission of 1,244,457.02 tCO2 for the end use in illumination and 169,570.05 tCO2 for cooling (fridge), totalizing 1,414,027.07 tCO2 over the period from 2009 to 2015. The study main focus was the development of the new Cost-benefit Ratio (RCB), where an RCB between 0.10 and 0.18 was obtained for the end use in lighting for traditional calculations and RCB between 0.08 to 0.17 adopting the Certified Emissions Reductions (CERs) calculated with the reduction of CO2, proving that both results were lower than the maximum established by ANEEL, thus providing a significant contribution to the other SES projects. For the end use in cooling, the results presented a traditional RCB between 0.97 and 1.62 and, increasing the CERs, the result showed the RCBs between 0.97 and 1.60. In the case of end use in cooling, both results exceed the maximum set by ANEEL, demonstrating that the application of this end use, alone, is not feasible for the PEE projects. Finally, it was possible to develop an Equivalent Virtual Power Plant (UVE), adopting the average real costs of the Hydroelectric Power Plant (HPP) and Small Hydroelectric Power Plant (PCH) buildings, obtaining a UVE of 77.27 MW of total power, for the analyzed projects. However, in spite of the discussions around this issue, the PEE projects promote improvements related to the demand of energy and electricity saving for the consumers of the end uses addressed. Thus, it was extremely important to follow these projects energy performance, in which factors that could potentiate the results were identified, according to the region where they will be applied. In addition, energy savings can contribute to the Energy Planning Company (EPE), which has been developing works to include such results in the Energy Efficiency Actions in the Ten-Year Energy Expansion Plan (PDE 2026)
30

Sistemas baseados em conhecimento para aplicação de eficiência energética e conservação de energia para plantas industriais. / Knowledge based systems for application of energy efficiency and energy conservation for industrial plants.

Buccieri, Gilberto Paschoal 22 March 2018 (has links)
Submitted by Gilberto Paschoal Buccieri (gilberto.buccieri@yahoo.com) on 2018-05-09T11:37:31Z No. of bitstreams: 1 Tese Gilberto Buccieri - Rev Final.pdf: 11720264 bytes, checksum: 2c06474cf0370f8ef9ba814aaea19486 (MD5) / Approved for entry into archive by Pamella Benevides Gonçalves null (pamella@feg.unesp.br) on 2018-05-10T14:13:23Z (GMT) No. of bitstreams: 1 buccieri_gp_dr_guara.pdf: 11720264 bytes, checksum: 2c06474cf0370f8ef9ba814aaea19486 (MD5) / Made available in DSpace on 2018-05-10T14:13:23Z (GMT). No. of bitstreams: 1 buccieri_gp_dr_guara.pdf: 11720264 bytes, checksum: 2c06474cf0370f8ef9ba814aaea19486 (MD5) Previous issue date: 2018-03-22 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Este trabalho apresenta o desenvolvimento de um protótipo de sistema especialista (SE) dotado de um módulo de geração de explicação (MGE) para diagnóstico preliminar de eficiência energética em plantas industriais, considerando as características fundamentais de operação e manutenção dessas plantas. Embora a capacidade de explicar processos de raciocínio distinga o SE de outros sistemas de apoio à decisão, disponibilizar um MGE ajuda a promover uma análise crítica das decisões tomadas pelo SE. Em adição, o MGE é muito útil também na validação da base de conhecimento, permitindo detectar erros semânticos do sistema e monitorar detalhes do processo de inferência, o que pode levar a uma redução de tempo de desenvolvimento e maior aceitação do sistema, aumentando dessa forma sua confiabilidade e principalmente, sua credibilidade. A base de conhecimento do sistema foi construída a partir da experiência de especialistas multidisciplinares da área de eficiência energética industrial, o que é certamente um recurso valioso em um contexto de gestão do conhecimento (GC) organizacional. A GC torna o conhecimento humano especializado em valor duradouro, criando uma memória corporativa por meio de ações de compartilhamento e retenção, o que pode contribuir para a melhoria contínua dos processos, criação de valor e manutenção de vantagens competitivas. Para demonstrar as possibilidades de melhoria de eficiência energética, os principais sistemas de utilidades de uma planta industrial são analisados de forma individual. Para tanto, tais sistemas são classificados como primário (energia elétrica, gás natural e água) e secundário (ar comprimido, ar condicionado, iluminação e sistemas de aquecimento). Estudos de caso são executados no protótipo SE para demonstrar como seu uso pode disseminar boas práticas de eficiência energética industrial, bem como de gestão de conhecimento, possibilitando criar uma memória corporativa permanentemente disponível nos computadores da organização e independente da disponibilidade de especialistas humanos. / This work presents the development of an expert system prototype (ES) with an explanation facility module (EFM) for preliminary diagnosis of energy efficiency guidelines in industrial plants, considering the fundamental characteristics of operation and maintenance of these plants. Although the ability to explain its own reasoning distinguishes ES from other decision support systems, providing an EFM contributes to promote a critical analysis of the decisions taken by the ES. In addition, the EFM is also very useful in validating the knowledge base, because it facilitates the detection of semantic errors and allows a better monitoring of the inference process. Because of that, the EFM can reduce the development time and contribute to a broader acceptance of the system, which positively impacts its reliability and credibility. The knowledge base of the system was built on the experience of multidisciplinary experts in the field of industrial energy efficiency that is certainly a valuable resource in an organizational knowledge management (KM) context. The KM becomes the human knowledge in permanent value by creating a corporate memory through sharing and retention actions that may contribute to continuous improvement of processes, value creation and maintaining competitive advantage. In order to properly demonstrate the possibilities of energy efficiency improvement, the main utility systems of an industrial plant are analyzed individually. To do so, such systems are classified as primary (power, natural gas and water) and the secondary (compressed air, air conditioning, lighting and heating systems). Case studies are performed in the ES prototype in order to show how its use can disseminate good energy efficiency practices and good knowledge management practices as well, making it possible to create a corporate memory permanently available on the organization's computers and independent of the availability of human experts. / CAPES - DS

Page generated in 0.4851 seconds