• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 192
  • 9
  • 9
  • 9
  • 9
  • 5
  • 4
  • 4
  • 2
  • 2
  • 2
  • Tagged with
  • 205
  • 205
  • 205
  • 92
  • 80
  • 79
  • 61
  • 40
  • 32
  • 30
  • 29
  • 28
  • 27
  • 26
  • 21
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
191

Determinação da frequência de autorressonância por onda estacionária em enrolamentos solenoidais e proposta de um sistema autorresonante de transferência de energia sem fio utilizando bobinas bifilares abertas / Determination os the selfresonant frequency by stationary-waves in solenoid coils and proposal of a self-resonant wireless power transfer system using open bifilar coils

Miranda, Caio Marcelo de 25 October 2016 (has links)
CAPES / Comuns em projetos de engenharia elétrica, bobinas solenoidais com núcleo de ar e camada simples de enrolamento podem apresentar frequência de autorressonância por efeitos de onda estacionária. A compreensão e determinação destas frequências é portanto de primordial interesse para os profissionais envolvidos com estes componentes. Neste trabalho é apresentada uma teoria que visa explicar o comportamento deste componentes quando em autorressonância por onda estacionária, sendo também desenvolvida uma equação prática que pode determinar tais valores de frequência. O comportamento da impedância nestes componentes também é discutido e demonstrado, onde, baseado nesta teoria, duas novas configurações são apresentadas: uma bobina com ambos terminais abertos e uma bobina com ambos terminais aterrados. Através de uma abordagem didática, correlaciona-se o enrolamento com um tubo de ar ressonante, e explica-se o que é registrado em termos de impedância e fase em um analisador vetorial de impedâncias ao conectar em seus terminais um enrolamento que apresenta autorressonância por onda estacionária. Uma análise da transferência de energia sem fio em circuitos ressonantes magneticamente acoplados é também apresentada, onde é destacada a relação entre eficiência, transferência relativa de potência e impedância refletida em circuitos com 2 e 4 bobinas. Um sistema de transferência de energia sem fio, utilizando bobinas bifilares abertas, é proposto. O sistema possui algumas vantagens uma vez que, a bobina bifilar aberta, ao contrário de uma bobina convencional, possui uma autorressonância série. Portanto, o sistema se comporta como um circuito contendo indutor e capacitor em série. Ainda, uma vez que o circuito dispensa o uso de capacitores, possibilita-se uma menor dimensão das unidades transmissora e receptora, além de se evitar eventuais danos aos capacitores em aplicações envolvendo maiores potências. / Common in electrical engineering projects, air-core single-layer solenoid coils can present self-resonant frequencies due to stationary waves effects. The comprehension and determination of these frequencies is of primordial interest for the professionals evolved with these components. In this work, a theory that aims to explain these components behavior at standing wave self-resonance is presented, a practical equation that can determine such frequency values is also developed. The impedance behavior in these components is also discussed and demonstrated, where, based in this theory, two new configurations are presented: a coil with both terminals open and a coil with both terminals grounded. Through a didactic approach the coil and a resonant air-pipe are correlated, and it is explained what is registered in terms of impedance and phase on a vector impedance analyzer when a standing wave self-resonant coil is connected on its terminals. An analysis of the wireless energy transfer in magnetically coupled resonant circuits is also presented, being emphasized the relation between efficiency, relative power transfer and reflected impedance in 2 and 4-coils circuits. A wireless power transfer system using open bifilar coils is proposed. The proposed system has the advantages that the open bifilar coil, different from a conventional coil, has a series self-resonance. Thus, the system behaves as a series-inductor capacitor circuit. Also, since the circuit avoids capacitors, it allows a smaller transmitter and receptor units dimensions, besides avoiding eventual damages to capacitors in higher power applications.
192

Segmentação, classificação e detecção de novas classes de eventos em oscilografias de redes de distribuição de energia elétrica

Lazzaretti, André Eugenio 27 February 2015 (has links)
CAPES / Este trabalho apresenta novas abordagens para duas das etapas fundamentais relacionadas com análise automática de oscilografias de redes de distribuição: a detecção dos instantes transitórios e a sua classificação. Para comparação e validação dos métodos são utilizadas duas bases de dados, sendo uma delas formada por dados simulados no aplicativo Alternative Transient Program e outra contendo dados reais de oscilógrafos instalados em uma rede de distribuição de energia elétrica. Os dados reais apresentam um conjunto de eventos relevante para as análises aqui propostas, principalmente por conter uma gama variada de eventos, incluindo transitórios decorrentes de descargas atmosféricas. Com relação à detecção de transitórios (segmentação de oscilografias), foram testados os métodos atualmente propostos na literatura, os quais contemplam Filtro de Kalman, Transformada Wavelet Discreta e Modelos Autorregressivos, além de serem propostas duas novas técnicas baseadas no Operador de Energia de Teager e Representação de Dados Utilizando Vetores Suporte. Demonstra-se que, tanto para dados simulados quanto para dados reais, o método de detecção baseado na Representação de Dados utilizando Vetores Suporte aponta para um melhor desempenho global no processo de detecção. Com relação à classificação automática de oscilografias, propõe-se uma nova abordagem incluindo um estágio dedicado à detecção de padrões não inseridos no aprendizado prévio do classificador, denominados de novidades, além da própria classificação multiclasse normalmente empregada para diferenciar múltiplas classes conhecidas a priori. São testadas abordagens utilizando a detecção de novidades e classificação multiclasse em estágios simultâneos e subsequentes, com base nos classificadores X-Médias, K-Vizinhos-Mais-Próximos e Representação de Dados Utilizando Vetores Suporte com diferentes formulações, além do próprio classificador multiclasse baseado em Máquinas de Vetor Suporte. Adicionalmente, é proposto um tratamento aos padrões considerados como novidades, com o intuito de fornecer informações ao especialista sobre as similaridades existentes entre os padrões desse conjunto. Para realizar esse processo, optou-se por utilizar modelos de agrupamento automático. Os resultados finais, principalmente para a base de dados incluindo eventos reais, mostram que é possível obter um desempenho de classificação relevante (acima de 80%) para cada um dos estágios do processo de classificação proposto, o qual inclui a detecção de novidades, a classificação multiclasse e o processamento de padrões classificados como novidades (agrupamento automático). / This work presents new approaches for two of the fundamental steps in automatic waveform analysis in electrical distribution systems: transient time detection and its classification. Two datasets were used to compare and validate the proposed methods. The first is composed by simulated waveforms, by using the Alternative Transient Program, while the second is formed by real data from a monitoring system developed for overhead distribution power lines. The real data present a set of relevant events for the analysis proposed here, mainly due to the variety of events, including lightning-related transients. Regarding transient detection (waveform segmentation), the experiments involve usual segmentation methods, such as Kalman filtering, standard Discrete Wavelet Transform, and autoregressive models, besides two new techniques based on the Teager Energy Operator and Support Vector Data Description. The results obtained on both simulated and real world data demonstrate that the method based on Support Vector Data Description outperforms other methods in the transient identification task. Regarding the automatic waveform classification, a new approach including the detection of classes not defined in the training stage (called novelties) is presented. Also, the classifier is able to discriminate among multiple known classes, normally defined as multi-class classification. Two different approaches are compared, by using multi-class classification and novelty detection in two subsequent stages and in a simultaneous way. The following classifiers were assessed: X-Means, K-Nearest-Neighbors, and Support Vector Data Description with different formulations, besides the Support Vector Machine for multi-class classification. Furthermore, a technique for the post-processing of the novelties is presented, in order to provide some useful information for the experts, regarding possible similarities in the novelty set. To accomplish this task, automatic clustering methods were used. The final results, especially for the dataset with real examples, show that it is possible to obtain a relevant classification performance (above 80%) in each one of the three stages of the classification process: multi-class classification, novelty detection, and the post-processing applied to the novelties (automatic clustering).
193

Análise computacional numérica do comportamento de ruptura dos solos em fundações superficiais com excentricidade gerada por cargas horizontais

Pereira, Paulo Henrique 30 May 2012 (has links)
Em subestações de transmissão e distribuição de energia elétrica são utilizadas estruturas metálicas ou de concreto para o suporte de equipamentos e ancoragem de linhas de transmissão. Nestas estruturas os esforços principais atuam horizontalmente pela ação do vento e da tração nos cabos de transmissão de energia elétrica. Devido aos baixos esforços verticais, normalmente, utilizam-se como solução fundações rasas, uma vez que apresentam menor custo e maior facilidade de execução quando comparadas com fundações profundas. Devido a distância de aplicação das cargas horizontais em relação à base, os momentos gerados por estas se tornam elevados em relação à carga vertical atuante. Esta configuração faz com que a resultante dos esforços, frequentemente, esteja fora do núcleo central da fundação. Segundo a NBR 6122 (1996), para a avaliação da capacidade de suporte das fundações nos casos de cargas excêntricas, deve ser adotada uma área efetiva onde os esforços de compressão são considerados uniformemente distribuídos. Este procedimento simplificado muitas vezes torna os dimensionamentos extremamente conservadores, tendo em vista os baixos carregamentos verticais e as grandes excentricidades. Esta pesquisa visa, através de utilização de modelos computacionais numéricos, caracterizar o comportamento de ruptura dos solos solicitados por fundações superficiais sujeitas a esforços combinados verticais, horizontais e momentos. Além disso, os resultados obtidos nos modelos numéricos são comparados com as formulações clássicas de dimensionamento de fundações. / For power substations, both steel and reinforced concrete structures are normally used to support the equipments and the high voltage wiring. In such cases, the wind forces predominate and cause tension in the electrical cables and structures. As the vertical loads are relatively small, generally shallow foundations apply, being also easily executed under lower costs. Due to the distance between the horizontal forces and the structural foundation, high moments are generated comparatively to the vertical loads present, defining big eccentricity in the foundation. According to ABNT-NBR 6122 (1996), to determine the foundation bearing capacity, an effective area way be considered for the compression stresses to act. This situation often yields to unrealistic foundation design. The present dissertation intend to model the failure behavior of the soil supporting shallow foundation by means of computational methods, considering vertical and horizontal forces acting along with moments. A comparison is also mode with commonly used bearing capacity equations for the same type of foundations.
194

Otimização de enlace indutivo ressonante com três bobinas para transmissão de energia sem fio / Three coil inductive resonant link optimization for wireless power transfer

Silva, Marcio Antonio Pimenta da 30 March 2017 (has links)
Transmissão de energia sem fio através de indução magnética ressonante foi primeiramente apresentada por Nikola Tesla há mais de um século, mas as limitações tecnológicas da época não possibilitaram sua imediata aplicação. Somente ao final do século XX que sistemas comerciais baseados nesta técnica puderam ser implementados. Atualmente é a tecnologia que se mostra mais adequada para transferência de energia para equipamentos móveis portáteis, como smartphones e tablets. Também hoje é a única tecnologia disponível que permite o desenvolvimento de veículos elétricos energizados dinamicamente, isto é, enquanto em movimento. Nesta técnica de transmissão de energia sem fio, independentemente do nível de complexidade da aplicação, a passagem da energia entre lado da transmissão e recepção se dá por meio de um enlace eletromagnético formado por bobinas ressonantes. Várias configurações de bobinas podem ser usadas na construção deste enlace. Neste trabalho será estudado um sistema baseado em um enlace composto por três bobinas montadas em alinhamento axial. O desempenho do sistema será avaliado em termos da potência entregue à carga, eficiência da transmissão de energia e alcance do enlace. Os resultados do sistema de três bobinas serão comparados aos resultados de um sistema composto por duas bobinas operando sob condições semelhantes. A comparação deixa clara a maior flexibilidade do sistema de três bobinas, que se mostra capaz de operar em uma faixa mais ampla de valores de eficiência e potência que o sistema de duas bobinas. Serão definidas as condições limites que permitam ao sistema de três bobinas operar com maior eficiência, maior potência entregue à carga ou maior alcance de enlace que aqueles obtidos com um sistema de duas bobinas. Serão também apresentados resultados reais que mostram, para condições específicas de operação, uma potência entregue à carga quase duas vezes maior que aquela possível com o sistema de duas bobinas e, ao mesmo tempo, uma eficiência praticamente três vezes maior. / Wireless power transfer through magnetic induction was first presented by Nikola Testla a century ago but, technical limitations did not let its immediate application at that time. It was only late of XX Century that commercial systems based on this technology could be offered. Nowadays this technology is considered the most appropriated to be used with portable devices like smartphones, tablets and so on. Additionally, it is the only technology available for dynamic charging of electric vehicles. In other words, charging while they are moving. In this kind of wireless power transfer technology, the energy transfer from the transmitter to the receiver is made through an electromagnetic link created by resonant coils. Several coils configurations can be used to implement the link. This work will focus on a system with three-coils assembled on axial alignment. The system performance will be evaluated in terms of power delivered to the load, efficiency and link distance. The three-coil system results will be compared with two-coil system results working under same operational conditions. That comparison points out the greater flexibility of three-coil system. This kind of system shows to be capable to function over a wider range of efficiency and power delivered to the load, which is not possible to the first one. Moreover, conditions under which the three-coil system shows to be more efficient, or able to deliver greater power to the load than two-coil system, will be discussed. Real data will be presented, as a case of a specific point of operation, in which the power delivered to the load is almost two times higher and efficiency is almost three times greater than the ones verified when using a two-coil system.
195

Determinação da frequência de autorressonância por onda estacionária em enrolamentos solenoidais e proposta de um sistema autorresonante de transferência de energia sem fio utilizando bobinas bifilares abertas / Determination os the selfresonant frequency by stationary-waves in solenoid coils and proposal of a self-resonant wireless power transfer system using open bifilar coils

Miranda, Caio Marcelo de 25 October 2016 (has links)
CAPES / Comuns em projetos de engenharia elétrica, bobinas solenoidais com núcleo de ar e camada simples de enrolamento podem apresentar frequência de autorressonância por efeitos de onda estacionária. A compreensão e determinação destas frequências é portanto de primordial interesse para os profissionais envolvidos com estes componentes. Neste trabalho é apresentada uma teoria que visa explicar o comportamento deste componentes quando em autorressonância por onda estacionária, sendo também desenvolvida uma equação prática que pode determinar tais valores de frequência. O comportamento da impedância nestes componentes também é discutido e demonstrado, onde, baseado nesta teoria, duas novas configurações são apresentadas: uma bobina com ambos terminais abertos e uma bobina com ambos terminais aterrados. Através de uma abordagem didática, correlaciona-se o enrolamento com um tubo de ar ressonante, e explica-se o que é registrado em termos de impedância e fase em um analisador vetorial de impedâncias ao conectar em seus terminais um enrolamento que apresenta autorressonância por onda estacionária. Uma análise da transferência de energia sem fio em circuitos ressonantes magneticamente acoplados é também apresentada, onde é destacada a relação entre eficiência, transferência relativa de potência e impedância refletida em circuitos com 2 e 4 bobinas. Um sistema de transferência de energia sem fio, utilizando bobinas bifilares abertas, é proposto. O sistema possui algumas vantagens uma vez que, a bobina bifilar aberta, ao contrário de uma bobina convencional, possui uma autorressonância série. Portanto, o sistema se comporta como um circuito contendo indutor e capacitor em série. Ainda, uma vez que o circuito dispensa o uso de capacitores, possibilita-se uma menor dimensão das unidades transmissora e receptora, além de se evitar eventuais danos aos capacitores em aplicações envolvendo maiores potências. / Common in electrical engineering projects, air-core single-layer solenoid coils can present self-resonant frequencies due to stationary waves effects. The comprehension and determination of these frequencies is of primordial interest for the professionals evolved with these components. In this work, a theory that aims to explain these components behavior at standing wave self-resonance is presented, a practical equation that can determine such frequency values is also developed. The impedance behavior in these components is also discussed and demonstrated, where, based in this theory, two new configurations are presented: a coil with both terminals open and a coil with both terminals grounded. Through a didactic approach the coil and a resonant air-pipe are correlated, and it is explained what is registered in terms of impedance and phase on a vector impedance analyzer when a standing wave self-resonant coil is connected on its terminals. An analysis of the wireless energy transfer in magnetically coupled resonant circuits is also presented, being emphasized the relation between efficiency, relative power transfer and reflected impedance in 2 and 4-coils circuits. A wireless power transfer system using open bifilar coils is proposed. The proposed system has the advantages that the open bifilar coil, different from a conventional coil, has a series self-resonance. Thus, the system behaves as a series-inductor capacitor circuit. Also, since the circuit avoids capacitors, it allows a smaller transmitter and receptor units dimensions, besides avoiding eventual damages to capacitors in higher power applications.
196

Segmentação, classificação e detecção de novas classes de eventos em oscilografias de redes de distribuição de energia elétrica

Lazzaretti, André Eugenio 27 February 2015 (has links)
CAPES / Este trabalho apresenta novas abordagens para duas das etapas fundamentais relacionadas com análise automática de oscilografias de redes de distribuição: a detecção dos instantes transitórios e a sua classificação. Para comparação e validação dos métodos são utilizadas duas bases de dados, sendo uma delas formada por dados simulados no aplicativo Alternative Transient Program e outra contendo dados reais de oscilógrafos instalados em uma rede de distribuição de energia elétrica. Os dados reais apresentam um conjunto de eventos relevante para as análises aqui propostas, principalmente por conter uma gama variada de eventos, incluindo transitórios decorrentes de descargas atmosféricas. Com relação à detecção de transitórios (segmentação de oscilografias), foram testados os métodos atualmente propostos na literatura, os quais contemplam Filtro de Kalman, Transformada Wavelet Discreta e Modelos Autorregressivos, além de serem propostas duas novas técnicas baseadas no Operador de Energia de Teager e Representação de Dados Utilizando Vetores Suporte. Demonstra-se que, tanto para dados simulados quanto para dados reais, o método de detecção baseado na Representação de Dados utilizando Vetores Suporte aponta para um melhor desempenho global no processo de detecção. Com relação à classificação automática de oscilografias, propõe-se uma nova abordagem incluindo um estágio dedicado à detecção de padrões não inseridos no aprendizado prévio do classificador, denominados de novidades, além da própria classificação multiclasse normalmente empregada para diferenciar múltiplas classes conhecidas a priori. São testadas abordagens utilizando a detecção de novidades e classificação multiclasse em estágios simultâneos e subsequentes, com base nos classificadores X-Médias, K-Vizinhos-Mais-Próximos e Representação de Dados Utilizando Vetores Suporte com diferentes formulações, além do próprio classificador multiclasse baseado em Máquinas de Vetor Suporte. Adicionalmente, é proposto um tratamento aos padrões considerados como novidades, com o intuito de fornecer informações ao especialista sobre as similaridades existentes entre os padrões desse conjunto. Para realizar esse processo, optou-se por utilizar modelos de agrupamento automático. Os resultados finais, principalmente para a base de dados incluindo eventos reais, mostram que é possível obter um desempenho de classificação relevante (acima de 80%) para cada um dos estágios do processo de classificação proposto, o qual inclui a detecção de novidades, a classificação multiclasse e o processamento de padrões classificados como novidades (agrupamento automático). / This work presents new approaches for two of the fundamental steps in automatic waveform analysis in electrical distribution systems: transient time detection and its classification. Two datasets were used to compare and validate the proposed methods. The first is composed by simulated waveforms, by using the Alternative Transient Program, while the second is formed by real data from a monitoring system developed for overhead distribution power lines. The real data present a set of relevant events for the analysis proposed here, mainly due to the variety of events, including lightning-related transients. Regarding transient detection (waveform segmentation), the experiments involve usual segmentation methods, such as Kalman filtering, standard Discrete Wavelet Transform, and autoregressive models, besides two new techniques based on the Teager Energy Operator and Support Vector Data Description. The results obtained on both simulated and real world data demonstrate that the method based on Support Vector Data Description outperforms other methods in the transient identification task. Regarding the automatic waveform classification, a new approach including the detection of classes not defined in the training stage (called novelties) is presented. Also, the classifier is able to discriminate among multiple known classes, normally defined as multi-class classification. Two different approaches are compared, by using multi-class classification and novelty detection in two subsequent stages and in a simultaneous way. The following classifiers were assessed: X-Means, K-Nearest-Neighbors, and Support Vector Data Description with different formulations, besides the Support Vector Machine for multi-class classification. Furthermore, a technique for the post-processing of the novelties is presented, in order to provide some useful information for the experts, regarding possible similarities in the novelty set. To accomplish this task, automatic clustering methods were used. The final results, especially for the dataset with real examples, show that it is possible to obtain a relevant classification performance (above 80%) in each one of the three stages of the classification process: multi-class classification, novelty detection, and the post-processing applied to the novelties (automatic clustering).
197

Análise computacional do desempenho de estratégia para o religamento controlado de linhas de transmissão

Gregory, Raquel Cristina Filiagi 25 July 2016 (has links)
Conselho Nacional de Desenvolvimento Científico e Tecnológico / A busca por soluções mitigatórias, no que tange aos efeitos das sobretensões transitórias atreladas às manobras de energizações e religamentos das linhas de transmissão, contemplam um tema desafiador e com fortes impactos sobre a coordenação de isolamento dos sistemas elétricos. Muito embora o reconhecimento de propostas clássicas e comerciais para a atenuação destes fenômenos, outras possibilidades, certamente, ainda são meritórias de destaque e investigações. Neste contexto, a presente dissertação encontra-se alicerçada na exposição dos fundamentos físicos e matemáticos de uma estratégia baseada em chaveamentos controlados, cujos instantes para o religamento da linha são pré-programados. A avaliação computacional da eficácia da metodologia é realizada utilizando o simulador ATP, no qual são efetuados estudos em um sistema elétrico típico submetido à curtos-circuitos sucedidos por desligamentos e subsequentes religamentos, sob a ação da tecnologia aqui focada e na ausência da mesma. / The search for mitigation solutions, with respect to the effects of overvoltages linked to the energization and reclosing maneuvers of transmission lines include a challenging subject with strong impact on the insulation coordination of electrical systems. Although the recognition of classical and commercial proposals to mitigate these phenomena, other possibilities are certainly still worthwhile highlighting and investigations. In this context, the present work is grounded in the exposure of the physical and mathematical foundations of a strategy based on controlled switchings, whose moments to the line reclosing are pre-programmed. The computational evaluation of the effectiveness of the methodology is made using the ATP simulator, which are studies in a typical electrical system subjected to the action of short-circuits fallowed by shutdowns and subsequent reclosing, under the action of technology here focused and lack thereof. / Dissertação (Mestrado)
198

Planejamento da expansão de sistemas de transmissão usando os modelos CC - CA e tecnicas de programação não-linear / Transmission systems expansion planning using DC-AC models and non-linear programming techniques

Rider Flores, Marcos Julio, 1975- 22 February 2006 (has links)
Orientador: Ariovaldo Verandio Garcia, Ruben Augusto Romero Lazaro / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-08-06T06:56:43Z (GMT). No. of bitstreams: 1 RiderFlores_MarcosJulio_D.pdf: 1021887 bytes, checksum: 6000961c2f5457b410ac691912476270 (MD5) Previous issue date: 2006 / Resumo: Neste trabalho são propostos modelos matemáticos e técnicas de solução para resolver o problema de planejamento da expansão de sistemas de transmissão através de três enfoques. a) Usando o modelo de corrente alternada do sistema de transmissão e um algoritmo heurístico construtivo especializado para resolver o problema de planejamento, e, ainda, realiza-se uma primeira tentativa de alocação de fontes de potência reativas; b) Usando o modelo de corrente contínua e técnicas de programação não-linear especializadas. Nesse caso emprega-se uma versão relaxada do problema de planejamento da expansão de sistemas de transmissão usando o modelo de corrente contínua, onde a integralidade das variáveis de investimento é desprezada. Resolve-se o problema de programação não-linear, modelado de forma matricial com um algoritmo de otimização especializado e, além disso, um algoritmo heurístico construtivo especializado é utilizado para resolver o problema de planejamento. c) Usando o modelo de corrente contínua e um algoritmo Branch and Bound (B&B) sem empregar técnicas de decomposição. Para isso foram redefinidos os chamados testes de sondagem no algoritmo B&B e em cada nó da árvore de B&B tem-se um problema de programação não-linear que são resolvidos usando a metodologia desenvolvida no item (b). Os ítens (a), (b) e (c) requerem a solução de problemas de programação não-linear diferenciados. Uma revisão das características principais da resolução iterativa dos métodos de pontos interiores é apresentada. Foi desenvolvida uma técnica baseada em uma combinação de métodos de pontos interiores de alta ordem (MPI-AO) para resolver os problemas de programação não-linear de forma rápida, eficiente e robusta. Essa combinação dos MPI-AO tem como objetivo colocar num único método as características particulares de cada um dos MPI-AO e melhorar o desempenho computacional comparado com os MPI-AO de forma individual / Abstract: In this work mathematical models and solution techniques are proposed to solve the power system transmission expansion planning problem through three approaches: a) Using the nonlinear model ofthe transmission system (AC model) and a specialized constructive heuristic algorithm to solve the problem and, yet, a first attempt to allocate reactive power sources is also considered; b) Using the direct-current (DC) model and specialized techniques of nonlinear programming. In this case a version of the power system transmission expansion planning problem using the DC model where the integrality of the investment variables is relaxed is used. The nonlinear programming problem is solved with a specialized optimization algorithm and, moreover, a constructive heuristic algorithm is employed to solve the planning problem. c) Using the DC model and Branch and Bound (B&B) algorithm without the use of decomposition techniques. The so called fathoming tests of the B&B were redefined and at each node of the tree a nonlinear programming problem is solved using the method developed in b). Items a), b) and c) require the solution of distinct problems of nonlinear programming. A revision of the main characteristics of the iterative solution of the interior points methods is presented. An optimization technique based on a combination of the higher order interior point methods (HO-IPM) had been developed to solve the nonlinear programming problems in a fast, efficient and robust way. This combination of the HO-IPM has as objective to explore the particular characteristics of each method in a single one and to improve the comparative computational performance with the HO-IPM of individual form / Doutorado / Energia Eletrica / Doutor em Engenharia Elétrica
199

Estudo do aspecto locacional da alocação de custos da transmissão = Study of the locational aspect in the transmission cost allocation problem / Study of the locational aspect in the transmission cost allocation problem

Tomiyama, Elias Kento, 1981- 21 August 2018 (has links)
Orientador: Carlos Alberto de Castro Júnior / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação / Made available in DSpace on 2018-08-21T03:54:49Z (GMT). No. of bitstreams: 1 Tomiyama_EliasKento_M.pdf: 3080864 bytes, checksum: 7293fe7b3271c5c27e9b967c48a4e245 (MD5) Previous issue date: 2012 / Resumo: Esta dissertação de mestrado apresenta quatro metodologias de alocação de custos da transmissão: Pro rata (PR), Divisão Proporcional (PS), Zbus-médio (Zbus_AVG) e Nodal. Enquanto a primeira desconsidera o aspecto locacional e aloca os custos baseado apenas na quantidade de potência produzida pelos geradores e consumida pelas cargas, as últimas três levam em conta este aspecto, ou seja, as tarifas pagas por geradores e cargas dependem do seu ponto de conexão na rede elétrica. Através de simulações computacionais são levantadas várias situações de operação no sentido de avaliar a influência e as possíveis implicações de ordem regulatória, política, econômica e social de um país provocadas pela inclusão do aspecto locacional na definição das tarifas de uso do sistema de transmissão. Por fim, mostra-se a possibilidade de se considerar as tarifas pagas pelos agentes do sistema como um critério de decisão a mais no problema do planejamento da expansão da transmissão / Abstract: This dissertation describes four transmission cost allocation methodologies: Pro rata (PR), Proportional sharing (PS), Zbus-average (Zbus_AVG) and Nodal. While the first one disregards the locational aspect and allocates costs based only on the amount of power delivered by generators and consumed by loads, the last three ones take this aspect into account, i.e. charges are dependent on where generators and demands are connected in the network. Several computer simulations were made in order to assess the influence of the locational aspect into transmission pricing scheme and the results were used for a critical analysis, including political, regulatory, economic and social aspects. Finally, we discuss the possibility of using the fees paid by transmission system agents as an additional criterion for the Transmission Expansion Planning problem / Mestrado / Energia Eletrica / Mestre em Engenharia Elétrica
200

Planejamento da expansão de sistemas de transmissão considerando análise de confiabilidade e incertezas na demanda futura /

Garcés Negrete, Lina Paola. January 2010 (has links)
Orientador: Rubén Augusto Romero Lázaro / Banca: Jose Roberto Sanches Mantovani / Banca: Anna Diva Plasencia Lotufo / Banca: Marcos Julio Rider Flores / Banca: Eduardo Nobuhiro Asada / Resumo: Nessa pesquisa tem-se por objetivo a análise teórica e a implementação computacional de duas propostas de solução ao problema de planejamento da expansão de sistemas de transmissão de energia elétrica considerando diferentes fatores relacionados com a confiabilidade do sistema e a adoção dos novos modelos de mercados elétricos. É importante notar, que no planejamento básico não são levados em conta esses importantes aspectos. Dessa forma, uma primeira aproximação considera um critério de confiabilidade para expandir o sistema, de forma que ele opere adequadamente no horizonte de planejamento satisfazendo um nível de confiabilidade pré-definido. O índice de confiabilidade utilizado para exigir esse nível de confiabilidade é o LOLE, que corresponde ao número médio de horas/dias em um período dado (normalmente um ano) no qual o pico da carga horária/diária do sistema possivelmente exceder'a a capacidade de geração disponível. O problema de planejamento considerando a confiabilidade é, portanto, formulado como um problema de otimização que minimiza o investimento sujeito ao critério de confiabilidade. O índice de confiabilidade para o sistema de transmissão é calculado para cada configuração, subtraindo o índice de confiabilidade do sistema de geração do sistema composto geração-transmissão (bulk power system ). Para calcular o índice no sistema composto geração transmissão, utiliza-se uma curva de duração de carga efetiva para este sistema. Esta curva acumulada de carga é obtida de um processo de convolução de outras duas curvas que representam a função de distribuição de probabilidade (FDP) das saídas aleatórias dos componentes do sistema e a curva de duração de carga, respectivamente. A avaliação de confiabilidade no sistema de geração é feita usando um método que calcula o índice de confiabilidade por meio dos momentos... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This work aims to the theoretical analysis and computational implementation of two proposals for the transmission expansion planning problem considering several factors such as system reliability and new electricity market structures. It is important to observe, that the basic planning does not consider these issues. Therefore, one first approach considers a reliability criterion to expand the system, so that it operates in adequate conditions in the horizon planning while satisfying pre-defined limits in the reliability index. Transmission system reliability criterion regards to LOLE, which refers to the number of hours/days in a specified period of time (normally one year), in which the hourly/daily peak load possibly will exceed the available generation capacity. So, the planning problem considering reliability is formulated as an optimization problem that minimizes the investment subject to probabilistic reliability criterion. Reliability index for the transmission system is calculated for each configuration by subtraction of generation and bulk power reliability indexes. A composite power system effective load curve is used for reliability analysis of the bulk power system. This accumulate curve is obtained convolving two curves, one of them corresponding to a probability distribution function of the random outages of the system components, and the other one corresponding to the load duration curve. Reliability assessment in the generation system is done using a method that calculates the reliability index through the statistics moments of the frequency distribution of equivalents loads. This curve is obtained by convolving the generation units which are dispached in merit order. The proposed model is solved using the specialized genetic algorithm of Chu-Beasley (AGCB). Detailed results on two test systems are analyzed and discussed. A second approach to the transmission expansion... (Complete abstract click electronic access below) / Doutor

Page generated in 0.0691 seconds