• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 192
  • 9
  • 9
  • 9
  • 9
  • 5
  • 4
  • 4
  • 2
  • 2
  • 2
  • Tagged with
  • 205
  • 205
  • 205
  • 92
  • 80
  • 79
  • 61
  • 40
  • 32
  • 30
  • 29
  • 28
  • 27
  • 26
  • 21
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
171

Software interativo com acesso a bancos de dados, modelos de componentes e metodos numericos visando estudos para a geração de cenarios de operação de redes de transmissão de energia / Interactive software with access to database, components models and numerical methods for generating of operation scenarios for energy transmission system

Spolador, Fernando Luis 27 June 2008 (has links)
Orientador: Anesio dos Santos Junior / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-08-11T13:45:20Z (GMT). No. of bitstreams: 1 Spolador_FernandoLuis_M.pdf: 2931500 bytes, checksum: 2b62ae2221ab4439c98ba66acde8bb13 (MD5) Previous issue date: 2008 / Resumo: Nesta dissertação é apresentada a proposta de um software para simulação e análise de sistemas de potência. A crescente necessidade de expansão dos sistemas elétricos e de validação destes sistemas nos mais diversos estados, fazem com que sejam necessários cada vez mais estudos. As simulações computacionais se apresentam como uma forma eficaz e de custo reduzido para a realização destes estudos, porém estas simulações acabam por gerar uma enorme quantidade de informações. O software proposto possui um conjunto de recursos, dentre eles, interfaces gráficas amigáveis com o usuário e manipulação de base de dados, que buscam fornecer as ferramentas necessárias para o processo de análise e efetiva busca de soluções para o modelo do sistema elétrico estudado. O software foi estruturado de forma a facilitar uma evolução continua e a inserção de novos recursos e funcionalidades. Palavras-chave: Sistema de Potência, Orientação a Objetos, Interface Gráfica com o Usuário / Abstract: This dissertation presents the proposal for a software for simulation and analysis of power systems. The growing need for expansion of electrical systems, the need for validation of these systems in the most diverse state, make it increasingly necessary studies of these systems. The computer simulations are presented as an effective and low cost for carrying out this study, but these simulations ultimately generate a huge amount of information. The software proposed has a set of resources, including friendly graphical user interfaces and manipulation of the databases, which seek to provide the tools necessary to the process of analysis and effective search for solutions to the model of the electrical system studied. The software has been structured to facilitate an ongoing evolution and inclusion of new features and functionality. Keywords: Power System, Object Oriented, Graphical User Interface / Mestrado / Energia Eletrica / Mestre em Engenharia Elétrica
172

Resposta transitória no domínio do tempo de uma linha de transmissão trifásica considerando uma nova implementação do efeito pelicular = Time domain transient response analysis of three-phase transmission line considering a new skin effect model / Time domain transient response analysis of three-phase transmission line considering a new skin effect model

Monteiro, José Humberto Araújo, 1981- 05 September 2014 (has links)
Orientadores: José Pissolato Filho, Eduardo Coelho Marques da Costa / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação / Made available in DSpace on 2018-08-25T04:23:41Z (GMT). No. of bitstreams: 1 Monteiro_JoseHumbertoAraujo_D.pdf: 2599049 bytes, checksum: 247f68cef0523b44c3d1e9c69dc48119 (MD5) Previous issue date: 2014 / Resumo: Este trabalho apresenta o desenvolvimento de um modelo de linha de transmissão trifásica utilizando uma nova implementação do efeito pelicular, além do estudo da resposta transitória obtida a partir do referido modelo quando surtos de manobra são simulados. A metodologia tradicionalmente utilizada para o cálculo da impedância interna de cabos sólidos cilíndricos faz uso das funções de Bessel, o que a torna complexa. A metodologia descrita por Gatous é tão precisa quanto a metodologia que utiliza as funções de Bessel e possui a vantagem de ser mais simples, visto que a solução final é um somatório cuja precisão depende da frequência estudada. O modelo desenvolvido neste trabalho emprega a metodologia de Gatous em uma linha de transmissão trifásica, cujos modos de propagação independentes são obtidos a partir da aplicação da matriz de Clarke. Para validar a metodologia de Gatous, foram calculadas a resistência e a indutância interna de cabos com raios variados em uma ampla faixa de frequências. Os resultados foram comparados aos obtidos a partir da metodologia tradicional. A metodologia de Gatous reproduziu com precisão a variação da impedância interna com a frequência. Para avaliar o funcionamento do modelo de linha de transmissão trifásico no domínio do tempo, um caso base foi estabelecido. Uma linha de transmissão trifásica de 69kV, circuito simples, foi submetida a chaveamentos de carga em duas situações distintas: chaveamento sendo executado no ponto de cruzamento com o zero da tensão e; chaveamento no ponto de 90° da tensão. Os transitórios de tensão e corrente foram obtidos a partir do modelo elaborado e comparados com os resultantes do software de análise de transitórios ATP. Os resultados alcançados reproduzem com fidelidade o comportamento transiente descrito pelo software supracitado / Abstract: This paper presents the development of a three-phase transmission line model using a new skin effect calculation and its transient response when some switching surges are applied to it. The methodology commonly used to calculate the internal impedance of solid conductors with cylindrical cross sectional area employs Bessel functions, which makes it a hard task to accomplish. Gatous, in his doctoral work, presented a new method to calculate skin effect impedance as accurate as Bessel¿s methodology with advantage of simplicity, whereas that final solution is an algebraic sum whose precision depends of frequency studied. The transmission line model developed in this work utilizes Gatous¿s method for skin effect impedance calculation in a three-phase transmission line, whose independent modes of propagation are obtained from the application of Clarke's matrix. In order to validate the mentioned methodology, internal resistances and inductances of cables with different size radii were calculated for a wide range of frequencies. The results were compared with those obtained through the traditional method, reproducing correctly the variation of the internal impedance with frequency. A base case was established to evaluate the operation of the three-phase transmission line in the time-domain model. A 69kV three-phase transmission line, single circuit, was subjected to switching load in two distinct situations: switching at zero crossing voltage and switching at voltage peak. Voltage and current transients were obtained from the developed model and compared with those derived from transient analysis software ATP. The results faithfully reproduced the transient behavior described by the above software / Doutorado / Energia Eletrica / Doutor em Engenharia Elétrica
173

Otimização de linhas de transmissão para manobra de abertura monopolar - análise da influência dos parâmetros transversais do sistema de compensação reativa / Optimization of transmission lines to single-phase opening maneuver - analysis of the influence of transversal parameters of shunt reactive compensation system

Zevallos Alcahuaman, Milton Elvis, 1974- 03 January 2013 (has links)
Orientador: Maria Cristina Dias Tavares / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação / Made available in DSpace on 2018-08-25T04:28:30Z (GMT). No. of bitstreams: 1 ZevallosAlcahuaman_MiltonElvis_D.pdf: 2479285 bytes, checksum: 4c1c5f42e8da1a073caee7cb88308479 (MD5) Previous issue date: 2013 / Resumo: Uma solução bastante utilizada para reduzir a corrente de arco secundário nas linhas aéreas de transmissão em extra-alta-tensão após a ocorrência de faltas monofásicas não permanentes é a inserção de um reator de neutro no arranjo dos reatores dos bancos de compensação reativa em derivação da linha. Muitas vezes estes reatores de neutro não são otimizados, de modo que reatores com valores típicos são especificados nos projetos de linhas de transmissão aéreas, baseados simplesmente no seu nível de tensão, mas sem considerar as especificidades das linhas, como as suas características físicas ou o seu comprimento. A especificação inadequada do reator de neutro pode resultar em correntes de arco secundário elevadas, o que, em última análise, pode reduzir a taxa de sucesso da manobra de religamento monopolar. Além disto, o custo do sistema de compensação pode ser maior do que o necessário. A tese apresenta uma extensa análise de sensibilidade dos principais parâmetros que influenciam no dimensionamento de um tronco de transmissão longo, especificamente do nível de compensação mais adequado e do valor ótimo do reator de neutro. Destaca-se na pesquisa o desenvolvimento de uma representação dos componentes de um sistema de transmissão através de quadripolos trifásicos com o intuito de obter a resposta sustentada durante o desequilíbrio. Através desta representação foi possível identificar a relação entre o reator de neutro ótimo e os parâmetros transversais da linha de transmissão, assim como a influência direta entre o nível de compensação do sistema com o valor do reator de neutro otimizado. Adicionalmente foram identificados comprimentos limites para linhas não compensadas de diferentes níveis de tensão de modo a ainda apresentar alta probabilidade de sucesso para a manobra monopolar. Simulações de faltas monofásicas foram realizadas utilizando dados provenientes de linhas típicas do sistema elétrico brasileiro / Abstract: A widely used solution to reduce secondary arc current in the overhead transmission lines in EHV after single-phase non permanents faults is the insertion of a neutral reactor in the arrangement forming part of the shunt reactive compensation of the line. Frequently in Brazilian electrical system, neutral reactors are not optimized, so that reactors with typical values are specified in the project of overhead transmission lines based on their voltage level, but without considering the specifics line parameters, as their physical characteristics or their length. The specification of unsuitable neutral reactor can result in high secondary arc currents, which eventually diminishes the success rate of single-phase automatic reclosure (SPAR) maneuver. Moreover, the cost of the compensation system may be larger than necessary. This paper presents an extensive sensitivity analysis of the main parameters that influence the project of a long transmission trunk, specifically the most appropriate level of compensation and the optimal value of the neutral reactor. It is noteworthy the development of a transmission system components representation using three-phase two-ports networks in order to obtain sustained response during unbalance. Through this analysis it was possible to identify the relationship between the shunt reactor and the optimized neutral parameter and the influence of the compensation level with the neutral reactor optimized value. Additionally the maximum lengths of non-compensated lines that would have high probability of success of SPAR maneuver were identified. Simulations of single-phase faults were performed using data from typical lines of the Brazilian electric system / Doutorado / Energia Eletrica / Doutor em Engenharia Elétrica
174

Falhas em linhas de transmissão elétrica na região sudeste do Brasil e efeitos do ambiente geofísico / Power transmission failures in southeastern Brazil and the effects geophysical environment

Duro, Magda Aparecida Salgueiro, 1968- 06 November 2013 (has links)
Orientadores: José Pissolato Filho, Pierre Kaufmann / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-08-23T01:41:59Z (GMT). No. of bitstreams: 1 Duro_MagdaAparecidaSalgueiro_D.pdf: 3861523 bytes, checksum: f5896319d2a3653a7903f977210f3ac1 (MD5) Previous issue date: 2013 / Resumo: A atual dependência da sociedade aos diversos sistemas tecnológicos em funcionamento na Terra traz uma constante preocupação pela sua vulnerabilidade a fatores menos conhecidos. As possíveis falhas no fornecimento de energia elétrica podem ocasionar transtornos de grande impacto às comunidades podendo acarretar perdas financeiras expressivas. Diversos fatores podem ocasionar falhas nas linhas de transmissão, entre eles, os fatores climáticos. Nesse contexto, são pouco conhecidas as influências qualitativas de distintos fatores, destacando-se os efeitos do denominado clima espacial. Há indicações que o clima espacial influencia a alta atmosfera terrestre, com repercussão no clima bem como em sistemas de engenharia em operação na Terra. As redes de transmissão de alta tensão representam um grande circuito elétrico pouco acima do solo sujeito a uma série de sobrecargas temporárias de vários tipos, algumas das quais podem levar a falhas. Algumas destas falhas podem estar relacionadas ao ambiente geofísico. Neste trabalho foi analisada uma base de dados sem precedentes de falhas em linhas de transmissão por um longo período (nove anos) numa grande malha localizada no Estado de São Paulo (sudeste do Brasil). O período estudado (1998-2006) compreende uma significativa fração do ciclo de atividade solar 23. A concessionária responsável (ISA.CTEEP) pela operação das linhas estudadas classifica as falhas em noventa e cinco tipos distintos de causas possíveis, sendo que a maior parte está relacionada às descargas atmosféricas. Este estudo está relacionado aos desligamentos devido às descargas atmosféricas, em duas redes de alta voltagem da companhia, de 138 kV e de 440 kV. No período estudado, estes desligamentos correspondem a 1.957 (42,80%) num total de 4.572 para a linha de 138 kV e de 170 (22,28%) sobre 763 para a linha de 440 kV. Equivale a menos de um a cada dez mil do número total de descargas atmosféricas ocorridas na mesma área, o que demonstra alta resiliência das redes de potência em relação aos raios. Durante a época das chuvas, há uma maior concentração de desligamentos. Para todo o período estudado houve redução de 67% e 77% no número de desligamentos devido às descargas atmosféricas, para as linhas de 138 kV e 440 kV, respectivamente, havendo uma boa correspondência com a redução do número de manchas solares. Nenhuma correlação foi encontrada em relação às atividades geomagnéticas caracterizadas pelo índice planetário (Kp) e pelas grandes tempestades (Dst) tanto em longos quanto em curtos prazos. Uma explicação sugerida associa a diminuição da atividade solar ao aumento da condutividade na atmosfera causada pelo maior fluxo de raios cósmicos. Consequentemente poderá ocorrer uma redução do limiar de voltagem necessário para produzir descargas atmosféricas para provocar desligamentos nas redes de alta voltagem. O circuito elétrico global descrito pelo acoplamento ionosfera-terra (a eletrosfera) exerce um papel importante para explicar a redução dos desligamentos. Com o aumento da condutividade atmosférica as descargas são menos potentes, resultando em menor número de desligamentos com o decréscimo do ciclo solar / Abstract: The current society dependence on the operating technological systems on the Earth brings a permanent concern for their vulnerability to not well known factors. Possible failures in electricity supply can cause inconveniences with large impact to the communities, which may cause significant financial losses. Different factors can cause failures in the transmission networks, including, climate factors. In this context, the influences of various qualitative factors, especially the effects of space weather are not well known. There are indications that space weather affects the upper atmosphere, with repercussions on the climate as well as in engineering systems in operation on Earth. High-voltage transmission networks represent large electrical circuits just above the ground which are subjected to a number of transient overcharges of various kinds, some of which may lead to failures. Some failures might be related to anomalies of the geophysical environment. In the present study we analyze a database consisting in a one unprecedented long series of transmission grid failures (nine years) on high-voltage networks located in São Paulo state (southeastern Brazil). The studied period (1998-2006) includes an important fraction of the solar activity cycle 23. The company responsible by the power grid operator (ISA.CTEEP) classifies causes in ninety-five distinct failure classes to explain the transmission grid shut downs. Most of the failures were attributed to atmospheric discharges. We have studied the failures attributed to atmospheric discharge, in the two power grids of the company, 138 kV and 440 kV. The failures attributed to atmospheric discharge correspond to 1.957 (42.80%) for a total 4.572 at 138 kV and to 170 (22.8%) out of 763 at 440 kV. They correspond to less than one ten thousandth of the actual number of atmospheric discharges recorded in the same area, demonstrating the grid's high resilience to breakdowns due to lightning. A clear concentration of failures in the region's thunderstorm season has been found. A significant 67% and 77% reduction in the number of failure rates has been found for the 138 and 440 kV grids, respectively, for the period studied, in good correspondence with the decay in the sunspot numbers. No obvious correlation was found between power failures and geomagnetic activity, represented by (Kp) the planetary index or major geomagnetic storms (Dst) in the period, either on short or on long time scales. One suggested explanation associates the decrease in solar activity to the increased conductivity in the atmosphere caused by increase cosmic ray flux. Consequently there may be a reduction in the threshold voltage necessary to produce discharge atmospheric to cause failures in high-voltage grids. The global electric circuit described by the ionosphere-ground coupling (the electrosphere), plays an important role in explaining the reduction the failures. With increase in conductivity atmospheric discharges are less potent, resulting in fewer failures with the decreasing solar cycle / Doutorado / Energia Eletrica / Doutor em Engenharia Elétrica
175

Método da barreira modificada via reescalonamento não linear aplicado ao fluxo de potência reativa ótimo / Modified barrier method by nonlinear rescaling applied to optimal reactive power flow

Silva, Iara da Cunha Ribeiro da, 1983- 08 May 2013 (has links)
Orientador: Anésio dos Santos Júnior / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação / Made available in DSpace on 2018-08-23T02:47:49Z (GMT). No. of bitstreams: 1 Silva_IaradaCunhaRibeiroda_D.pdf: 1773553 bytes, checksum: 06519e6714ec628c0365a39c3384366d (MD5) Previous issue date: 2013 / Resumo: Nesta tese é apresentado o método da barreira modificada via princípio de reescalonamento não linear aplicado ao fluxo de potência reativa ótimo. Esse método é baseado na transformação das restrições de desigualdade do fluxo de potência reativa ótimo, gerando um problema de barreira modificado. Resolvendo uma sequência desses problemas barreira modificado, o método pode alcançar a solução do fluxo de potência reativa ótimo. A estratégia de busca é composta por dois ciclos: o primeiro minimiza a função Lagrangeana associada ao problema de barreira modificada através do método de Newton e o segundo ciclo atualiza as variáveis duais do problema não linear. O método barreira modificado é aplicado em sistemas elétricos do IEEE e os resultados são apresentados na tese / Abstract: In this thesis is presented the modified barrier method, based on the nonlinear rescaling principle and applied to the problem for optimal reactive power flow. This method is based on the transformation of nonlinear inequality constraints of the optimal power flow that generates a modified barrier problem. On searching the solution of a sequence of these problems the method can achieve the solution of the optimal power flow. The search strategy is composed by two stages: the first one update the dual variable approximation of inequality constraints of the problem. The second one minimizes the Lagrangian function of the modified barrier problem by Newton's method. This strategy has been applied to optimal power flow IEEE systems and the results are also shown in this thesis / Doutorado / Energia Eletrica / Doutora em Engenharia Elétrica
176

Estudo de variantes da particle swarm optimization aplicadas ao planejamento da expansão de sistemas de transmissão / Study of particle swarm optimization variations applied to transmission system expansion planning

Barreto Alferez, Wilmer Edilberto, 1976- 10 November 2013 (has links)
Orientadores: Carlos Alberto de Castro Júnior, Santiago Patricio Torres Contreras / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação / Made available in DSpace on 2018-08-23T20:25:48Z (GMT). No. of bitstreams: 1 BarretoAlferez_WilmerEdilberto_M.pdf: 1213079 bytes, checksum: be23433dda22950612c8e4039b4ebba4 (MD5) Previous issue date: 2013 / Resumo: O planejamento da expansão da transmissão (PET) consiste em determinar todas as alterações necessárias na infraestrutura do sistema de transmissão, ou seja, ampliações e reforços, a fim de permitir o equilíbrio entre a demanda prevista e o suprimento de energia elétrica, procurando o investimento mínimo ao longo do horizonte de planejamento. O PET é um problema de grande extensão, inteiro misto, não linear, e não convexo. Portanto, mais técnicas de otimização devem ser investigadas para resolvê-lo de forma eficiente. Neste trabalho de pesquisa, o foco do estudo foi a metaheurística de otimização por enxame de partículas (PSO) aplicada ao problema PET estático. Os desempenhos das variantes Global (GPSO) e Local (LPSO) são comparados com quatro novas variantes do PSO baseado no comportamento quântico de otimização por enxame de partículas (QPSO). QPSO considera um comportamento quântico dos movimentos de partículas, de acordo com a mecânica quântica, que, em teoria, levaria a uma melhor convergência global do que o tradicional PSO. Esta pesquisa utiliza o modelo DC das redes de potência, considerando restrições de segurança usando o critério . Os conhecidos sistemas Garver, IEEE de 24 barras, e equivalente sul brasileiro de 46 barras são usados para apresentar os resultados deste trabalho de pesquisa / Abstract: The Transmission Expansion Planning (TEP) consists of determining all the changes needed in the transmission system infrastructure, i.e. additions and reinforcements, in order to allow the balance between the projected demand and the power supply, at minimum investment along the planning horizon. The TEP is a large scale, mixed-integer, non-linear and non-convex problem. Therefore more optimization techniques must be investigated to solve it in an efficient way. In this research work, the focus was on the study of the optimization metaheuristics by particle swarm (PSO) applied to the static version of the TEP problem. The performances of the Global (GPSO) and Local (LPSO) variants are compared against four new PSO variants based on the Quantum-behaved Particle Swarm Optimization (QPSO). QPSO considers a quantum behavior of particles' movements, according to quantum mechanics, which in theory would lead to a better global convergence than traditional PSO. This research uses the DC model for the network and takes into account security constraints using the well-known criterion. The well-known Garver, IEEE 24-bus, and the 46-bus Southern Brazilian equivalent networks will be used to present the results of this research work / Mestrado / Energia Eletrica / Mestre em Engenharia Elétrica
177

Otimização da programação da manutenção dos ativos de transmissão do sistema elétrico brasileiro considerando penalidades por indisponibilidade, restrições sistêmicas e logística das equipes técnicas / Optimization of maintenance programming of transmission assets of the brazilian electric power system considering penalties for unavailability, systemic constraints and logistics technical teams

Araujo Neto, José Evangelista, 1977- 19 August 2018 (has links)
Orientador: Antonio Carlos Moretti / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Matemática, Estatística e Computação Científica / Made available in DSpace on 2018-08-19T06:41:26Z (GMT). No. of bitstreams: 1 AraujoNeto_JoseEvangelista_M.pdf: 2884766 bytes, checksum: c57ca36e07463336bdf238ea6b35e234 (MD5) Previous issue date: 2011 / Resumo: Uma empresa de energia elétrica tem por obrigação garantir a continuidade e a qualidade do serviço prestado. A fim de incentivar a qualidade do serviço, a ANEEL introduziu penalidades nos contratos com as concessionárias de serviços públicos de transmissão de energia elétrica caso as instalações de transmissão sejam desligadas, por acidente, falha de equipamento ou manutenção programada. Abordagens tradicionais de manutenção em sistemas de transmissão de energia elétrica se baseiam em ações realizadas periodicamente, ou programadas, de acordo com uma análise de necessidades. Embora essas abordagens tenham o objetivo de melhorar o desempenho destes sistemas, geralmente não há uma avaliação precisa do impacto das ações de manutenção na confiabilidade dos mesmos relacionada aos recursos empregados, bem como penalidades legais decorrentes. O objeto assim formulado caracteriza-se como um problema de otimização combinatória com o objetivo de encontrar o encadeamento das ações de manutenções que minimizem os recursos utilizados em manutenções e garanta um nível de confiabilidade desejado para o Sistema Elétrico. Este trabalho propõe uma abordagem para enfrentar este problema baseada na relação confiabilidade/custo com a perspectiva de encontrar as melhores estratégias para a realização de manutenções em equipamentos (ativos) de transmissão de energia elétrica, apresentando um modelo matemático para a confecção de um calendário viável (que respeite às restrições do Sistema Elétrico) para programação de manutenção nestes ativos e metodologia de otimização para encontrar as melhores soluções em um determinado horizonte de planejamento / Abstract: A eletric power company is required to ensure continuity and quality of the provided service. To promote the quality of service, ANEEL introduced penalties in contracts with the electric power companies if transmission facilities are turned off by accident, equipment failure or programmed maintenance. Traditional approaches to maintenance of electric energy transmission systems are based on actions performed periodically, or programmed, in agreement with an analysis of needs. Although these approaches have the goal of improving the performance of these systems, generally there is not an accurate assessment of the impact of maintenance actions on the reliability of those actions related to the employed resources, as well as current legal penalties. The object thus formulated is characterized as a combinatorial optimization problem with the objective to find the sequence of maintenance actions that minimize the resources used in maintenance, ensuring a level of reliability desired for the Electric System. This work proposes an approach to address this problem based on the relationship reliability/ cost with the prospect of finding the best strategies for performing maintenance on equipment (assets) of electricity transmission, presenting a mathematical model for finding a feasible schedule (which respects the constraints of the Electric System) maintenance programming for these assets and optimization methodology to find the best solutions in a given planning horizon / Mestrado / Matematica Aplicada / Mestre em Matemática Aplicada
178

Utilização de linhas de transmissão semelhantes no ensaio de energização de um tronco com pouco mais de meio comprimento de onda / Utilization of similar transmission lines on energization test of a trunk with a little more than a half-wavelength

Gomes, Elson Costa, 1986- 19 August 2018 (has links)
Orientador: Maria Cristina Dias Tavares / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação / Made available in DSpace on 2018-08-19T21:10:18Z (GMT). No. of bitstreams: 1 Gomes_ElsonCosta_M.pdf: 4986234 bytes, checksum: 3e2729d9cbec861f21c958f84db0b17e (MD5) Previous issue date: 2012 / Resumo: O transporte de grandes blocos de energia elétrica através de longas distâncias que variam de 2500 a 3000 km impõe a utilização de soluções mais adequadas baseadas em linhas de transmissão não convencionais. Uma alternativa em corrente alternada (CA) é a linha com pouco mais de meio comprimento de onda, que para o caso brasileiro, cuja frequência industrial é 60 Hz, apresenta comprimento físico de aproximadamente 2600 km. Por não existir no mundo um sistema similar em operação, foi proposta a realização da manobra de energização de um Elo CA Teste composto pela conexão em série de três interligações do sistema brasileiro que têm características elétricas semelhantes e que juntas formam um tronco de 2600 km. O presente trabalho visa avaliar a adequação de se utilizar um tronco formado por linhas semelhantes para representar um tronco de um pouco mais de meio comprimento de onda durante a manobra de energização da linha em vazio. Através de análise da resposta dos parâmetros das linhas no domínio da frequência e de simulações no domínio do tempo realizadas com os programas computacionais ATP e PSCAD/EMTDC para a avaliação de transitórios, observou-se que o uso do tronco proposto para o ensaio de energização é adequado e foram determinados valores limites para as diferenças entre características elétricas das linhas que podem compor sistemas com pouco mais de meio comprimento de onda, fornecendo importantes subsídios para a possível realização do referido ensaio em outros locais do mundo / Abstract: The transportation of large blocks of energy through very long distances between 2500 and 3000 km requires an extensive research for the best solutions based on non-conventional transmission systems. A very interesting alternative is the AC transmission with a little more than half-wavelength, which corresponds to a transmission line of 2600 km in systems like the Brazilian, with 60 Hz fundamental frequency. However, as there is no similar system in operation around the world, it was proposed a realization of the energization of an AC-Link Test composed of three interconnection trunks that have similar electrical characteristics that together can form a trunk of 2600 km. In this work it is evaluated the adequacy of using a trunk formed by similar lines to represent a line of a little more than a half wave-length during an energization maneuver. The response of AC-Link Test parameters in frequency domain and time domains simulations performed with the computer programs ATP and PSCAD/EMTDC, to evaluate transient response, showed that the proposed use of the trunk for the energization is appropriate. It was also identified limits for the differences between electrical characteristics of the lines that can form a trunk with a little more than a half-wavelength, contributing to the possible realization of the same test in other parts of the world / Mestrado / Energia Eletrica / Mestre em Engenharia Elétrica
179

EDF and the Brazilian power sector

Masvigner, Raphael Charlie Jean 09 May 2012 (has links)
Submitted by Eliene Soares da Silva (eliene.silva@fgv.br) on 2012-06-12T15:47:45Z No. of bitstreams: 1 Raphael Masvigner - Master Thesis Final Version.pdf: 2997019 bytes, checksum: 97b22fc58e812cb12d6b408b5d47f149 (MD5) / Approved for entry into archive by Eliene Soares da Silva (eliene.silva@fgv.br) on 2012-06-12T15:52:34Z (GMT) No. of bitstreams: 1 Raphael Masvigner - Master Thesis Final Version.pdf: 2997019 bytes, checksum: 97b22fc58e812cb12d6b408b5d47f149 (MD5) / Made available in DSpace on 2012-06-12T16:59:51Z (GMT). No. of bitstreams: 1 Raphael Masvigner - Master Thesis Final Version.pdf: 2997019 bytes, checksum: 97b22fc58e812cb12d6b408b5d47f149 (MD5) Previous issue date: 2012-05-09 / Electricité de France (EDF) is a leading player in the European energy market by being both the first electricity producer in Europe and the world’s leading nuclear plant operator. EDF is also the first electricity producer and supplier in France. However, Europe, EDF’s core market, is currently underperforming: the European sovereign debt crisis is lowering significantly the growth perspective of an energy market that has already reached its maturity. As a consequence, European energy companies are now looking at international markets and especially BRIC economies where economic growth potential remains high. Among them, Brazil is expected to keep its strong economic and electricity demand growth perspectives for the coming decades. Though Brazil has not been considered as a strategic priority for EDF after the Light reversal in 2006, the current economic situation has led the Group to reconsider its position toward the country. EDF’s current presence in Brazil is limited to its stake in UTE Norte Fluminense, a thermal plant, located in the state of Rio de Janeiro. This report investigates the possibility and the feasibility of EDF’s activities expansion in Brazil and what added value it could bring for the Brazilian power market. Considering that the status quo would not allow EDF to take full advantage of Brazil’s future growth, this work is identifying the various options that are currently opened to EDF: market exit, status quo, EDF alone, local partner. For that purpose, this study collects and analyses the latest energy market data as well as generation companies’ information which are necessary to give a relevant overview of the current brazilian power sector and to present EDF strategic options for the country.
180

Uma retrospectiva da expansão do sistema eletrico na bacia do rio Tocantins, com estudo de caso na região de Lajeado - Palmas - Porto Nacional, (TO), 1996-2003

Araujo, Rubens Milagre 03 August 2018 (has links)
Orientador: Arsenio Oswaldo Seva Filho / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-08-03T20:42:57Z (GMT). No. of bitstreams: 1 Araujo_RubensMilagre_M.pdf: 2911200 bytes, checksum: 1c03f2313582267056d61e545efb9699 (MD5) Previous issue date: 2003 / Mestrado

Page generated in 0.1108 seconds