1

Avaliação da eficácia da limpeza e desinfecção de alto nível na remoção do biofilme em canais de endoscópios / Evaluation of cleaning efficacy and high level disinfection whem removing biofilm from endoscopes channels

Ana Cristina Balsamo 18 February 2009 (has links)
Os endoscópios são equipamentos aprovados para serem reutilizados, apesar de apresentarem estrutura interna complexa, composta por canais longos com lúmens estreitos, o que permite a aderência de matéria orgânica e microrganismos, favorecendo assim a formação de biofilmes. Estes dificultam o processamento eficaz, representando um desafio no reuso desses equipamentos. A formação do biofilme é inevitável ao longo do processamento dos endoscópios e há grande dificuldade em removê-lo completamente. Em razão disso, pesquisas atuais apontam-no como possível responsável pela transmissão de infecções exógenas e efeitos adversos que se manifestam em pacientes submetidos a endoscopias gastrointestinais. Essa realidade tem trazido à tona a preocupação em erradicá-lo. Assim, este estudo teve como objetivos avaliar a ação da desinfecção de alto nível na remoção de biofilme após limpeza prévia com escovação em corpos amostrais, simulando os canais de endoscópios flexíveis e comparar os produtos comercialmente disponíveis no mercado nacional para a remoção do biofilme dos endoscópios. Trata-se de uma pesquisa experimental, laboratorial e comparativa. Foram utilizados tubos de revestimento interno de politetrafluoretileno (Teflon®) e a Pseudomonas aeruginosa como microrganismo teste, formadora de biofilme. Foi montado um modelo validado para o desenvolvimento do biofilme. Os corpos amostrais contaminados foram submetidos inicialmente ao processo manual de limpeza com detergente enzimático e escovação. Em seguida, os corpos amostrais foram submetidos a cinco métodos de desinfecção de alto nível, quais sejam: o ácido peracético com concentração de 0,09% a 0,15%, o sistema Steris®, o glutaraldeído a 2%, e a água eletrolítica ácida. Foram extraídos três segmentos, de aproximadamente três milímetros representando o início, meio e fim de cada corpo amostral e analisados com o auxílio da microscopia eletrônica de varredura quanto a presença de biofilme. Conclui-se que nenhum método testado removeu 100% dos biofilmes e que essa remoção depende da interação entre o método de limpeza e a desinfecção posterior. Verificou-se que o método que mais removeu fisicamente o biofilme foi o glutaraldeído a 2% em reprocessadora automática, provavelmente justificado pelo double brushing, uma vez que o equipamento tem uma fase de limpeza no início de seu ciclo. O método que se mostrou mais eficaz na remoção de biofilme e outros resíduos constituídos de bactérias isoladas e da matriz de exopolissacarídeos, foi sistema Steris®. O método que se mostrou menos eficaz na remoção do biofilme e outros resíduos foi a água eletrolítica ácida. Considerando que a água é uma fonte de biofilme, sugeri-se utilizar filtros para a água do enxágüe e a rinsagem final dos canais com álcool. A despeito de tecnologias atualmente disponíveis para o processamento de canais dos endoscópios, nenhum dos métodos testados na presente investigação foi completamente eficaz para remover os biofilmes frente ao desafio imposto. Resta, portanto, recomendar que práticas baseadas em protocolos das sociedades sejam rigorosamente seguidas, apesar do tempo requerido para as boas práticas e optar, preferencialmente pelo processo automatizado, a fim de diminuir o erro humano / Endoscope is equipment approved to be reused in spite of its complex internal structure, consisting of long channels with narrowed lumens, allowing adherence of organic material and microorganisms, favoring formation of biofilm, making difficult an effective procedure, which is a challenge in the reuse of this equipment. The biofilm formation during endoscopic procedures is inevitable and it is very difficult to entirely remove it. Consequently, recent researches report it as the probable factor responsible by transmissions of exogenous infections and for the side effects found in patients submitted to gastrointestinal endoscopy procedures. This picture brought the concern to eradicate it. Thus, the objectives of this study were to evaluate the action of high level disinfection to remove biofilm after prior cleaning and brushing in body samples, simulating flexible endoscopic channels and to compare products commercially available in the national market to remove the biofilm from endoscopes. This is an experimental, laboratory and comparative research. Tubes of internal politetrafluorethylen (Teflon) and the Pseudomonas aeruginosa as a test microorganism to form the biofilm. A validated model was designed to develop the biofilm. The contaminated body samples were initially submitted to manual cleaning process with enzymatic cleansing and brushing. Next, these bodies were submitted to five high-level disinfection methods, as follows: peracetic acid at 0.09% and 0.15% of concentration, Steris System, 2% glutaraldehyde and acid electrolytic water. Three segments were removed, measuring approximately three millimeters, representing the beginning, the middle and the end of each body sample. These segments were analyzed by means of screening electronic microscopy in relation to biofilm presence. It was concluded that no tested method removed 100% of biofilm and that this removal depends on the interaction between the cleaning method and later disinfection. It was observed that the most effective procedure to physically remove the biofilm was the 2% glutaraldehyde, in automatic reprocessing method, probably due to double brushing since the equipment had a cleaning phase at the beginning of the cycle. The most effective method to remove the biofilm and other residues of isolated bacteria and of exopolysaccaride matrix was the SterisSystem method. The less effective method to remove biofilm and other residues was the acid electrolic water. Considering that water is the biofilm source, it was suggested to use filters for the water when cleansing and to rinse the channels with alcohol at the end. Regarding new technologies available for processing endoscope channels, none of the tested methods in the present investigation was totally effective to remove biofilm in face of the challenge presented. So, we may suggest that the good practices recommended by the several existing societies be strictly followed, in spite of the time needed for this process. Automated process is suggested as the best option to decrease human error
2

Avaliação da eficácia da limpeza e desinfecção de alto nível na remoção do biofilme em canais de endoscópios / Evaluation of cleaning efficacy and high level disinfection whem removing biofilm from endoscopes channels

Balsamo, Ana Cristina 18 February 2009 (has links)
Os endoscópios são equipamentos aprovados para serem reutilizados, apesar de apresentarem estrutura interna complexa, composta por canais longos com lúmens estreitos, o que permite a aderência de matéria orgânica e microrganismos, favorecendo assim a formação de biofilmes. Estes dificultam o processamento eficaz, representando um desafio no reuso desses equipamentos. A formação do biofilme é inevitável ao longo do processamento dos endoscópios e há grande dificuldade em removê-lo completamente. Em razão disso, pesquisas atuais apontam-no como possível responsável pela transmissão de infecções exógenas e efeitos adversos que se manifestam em pacientes submetidos a endoscopias gastrointestinais. Essa realidade tem trazido à tona a preocupação em erradicá-lo. Assim, este estudo teve como objetivos avaliar a ação da desinfecção de alto nível na remoção de biofilme após limpeza prévia com escovação em corpos amostrais, simulando os canais de endoscópios flexíveis e comparar os produtos comercialmente disponíveis no mercado nacional para a remoção do biofilme dos endoscópios. Trata-se de uma pesquisa experimental, laboratorial e comparativa. Foram utilizados tubos de revestimento interno de politetrafluoretileno (Teflon®) e a Pseudomonas aeruginosa como microrganismo teste, formadora de biofilme. Foi montado um modelo validado para o desenvolvimento do biofilme. Os corpos amostrais contaminados foram submetidos inicialmente ao processo manual de limpeza com detergente enzimático e escovação. Em seguida, os corpos amostrais foram submetidos a cinco métodos de desinfecção de alto nível, quais sejam: o ácido peracético com concentração de 0,09% a 0,15%, o sistema Steris®, o glutaraldeído a 2%, e a água eletrolítica ácida. Foram extraídos três segmentos, de aproximadamente três milímetros representando o início, meio e fim de cada corpo amostral e analisados com o auxílio da microscopia eletrônica de varredura quanto a presença de biofilme. Conclui-se que nenhum método testado removeu 100% dos biofilmes e que essa remoção depende da interação entre o método de limpeza e a desinfecção posterior. Verificou-se que o método que mais removeu fisicamente o biofilme foi o glutaraldeído a 2% em reprocessadora automática, provavelmente justificado pelo double brushing, uma vez que o equipamento tem uma fase de limpeza no início de seu ciclo. O método que se mostrou mais eficaz na remoção de biofilme e outros resíduos constituídos de bactérias isoladas e da matriz de exopolissacarídeos, foi sistema Steris®. O método que se mostrou menos eficaz na remoção do biofilme e outros resíduos foi a água eletrolítica ácida. Considerando que a água é uma fonte de biofilme, sugeri-se utilizar filtros para a água do enxágüe e a rinsagem final dos canais com álcool. A despeito de tecnologias atualmente disponíveis para o processamento de canais dos endoscópios, nenhum dos métodos testados na presente investigação foi completamente eficaz para remover os biofilmes frente ao desafio imposto. Resta, portanto, recomendar que práticas baseadas em protocolos das sociedades sejam rigorosamente seguidas, apesar do tempo requerido para as boas práticas e optar, preferencialmente pelo processo automatizado, a fim de diminuir o erro humano / Endoscope is equipment approved to be reused in spite of its complex internal structure, consisting of long channels with narrowed lumens, allowing adherence of organic material and microorganisms, favoring formation of biofilm, making difficult an effective procedure, which is a challenge in the reuse of this equipment. The biofilm formation during endoscopic procedures is inevitable and it is very difficult to entirely remove it. Consequently, recent researches report it as the probable factor responsible by transmissions of exogenous infections and for the side effects found in patients submitted to gastrointestinal endoscopy procedures. This picture brought the concern to eradicate it. Thus, the objectives of this study were to evaluate the action of high level disinfection to remove biofilm after prior cleaning and brushing in body samples, simulating flexible endoscopic channels and to compare products commercially available in the national market to remove the biofilm from endoscopes. This is an experimental, laboratory and comparative research. Tubes of internal politetrafluorethylen (Teflon) and the Pseudomonas aeruginosa as a test microorganism to form the biofilm. A validated model was designed to develop the biofilm. The contaminated body samples were initially submitted to manual cleaning process with enzymatic cleansing and brushing. Next, these bodies were submitted to five high-level disinfection methods, as follows: peracetic acid at 0.09% and 0.15% of concentration, Steris System, 2% glutaraldehyde and acid electrolytic water. Three segments were removed, measuring approximately three millimeters, representing the beginning, the middle and the end of each body sample. These segments were analyzed by means of screening electronic microscopy in relation to biofilm presence. It was concluded that no tested method removed 100% of biofilm and that this removal depends on the interaction between the cleaning method and later disinfection. It was observed that the most effective procedure to physically remove the biofilm was the 2% glutaraldehyde, in automatic reprocessing method, probably due to double brushing since the equipment had a cleaning phase at the beginning of the cycle. The most effective method to remove the biofilm and other residues of isolated bacteria and of exopolysaccaride matrix was the SterisSystem method. The less effective method to remove biofilm and other residues was the acid electrolic water. Considering that water is the biofilm source, it was suggested to use filters for the water when cleansing and to rinse the channels with alcohol at the end. Regarding new technologies available for processing endoscope channels, none of the tested methods in the present investigation was totally effective to remove biofilm in face of the challenge presented. So, we may suggest that the good practices recommended by the several existing societies be strictly followed, in spite of the time needed for this process. Automated process is suggested as the best option to decrease human error
3

Análise da carga microbiana nos instrumentos utilizados em cirurgias ortopédicas / Analysis of the microbial load in the instruments used in orthopedic surgeries

Pinto, Flávia Morais Gomes 29 April 2009 (has links)
O insucesso nos procedimentos cirúrgicos ortopédicos em razão de infecção pode levar a consequências desastrosas como a osteomielite e a perda de próteses implantadas. A infecção hospitalar é um desfecho de causa multifatorial, na qual a esterilização segura do instrumental cirúrgico ocupa uma posição de extrema importância. Não se sabe até o momento quais os reais desafios microbiológicos que a Central de Material e Esterilização (CME) vem enfrentando ao reprocessar a diversidade dos materiais utilizados nos procedimentos cirúrgicos. Micro-organismos com capacidade para esporular estão presentes em quantidade e frequência significativa? Sabe-se que estes se constituem como desafio mensurável na prática da esterilização, fazendo parte de indicadores biológicos. O objetivo desta pesquisa foi determinar e analisar a carga microbiana recuperada do instrumental cirúrgico, após uso em cirurgias ortopédicas, quantificando e identificando o gênero e a espécie do crescimento de bactérias e fungos. A investigação caracterizou-se como uma pesquisa exploratória, de campo e transversal com abordagem quantitativa. As amostras foram coletadas no Instituto de Ortopedia e Traumatologia (IOT) do Hospital das Clínicas (HC) da Faculdade de Medicina da Universidade de São Paulo (FMUSP), com técnica asséptica, depositando-as individualmente em um saco plástico previamente esterilizado, adicionando 500 mL de água de injeção. Para obtenção da carga microbiana, o instrumental foi sonicado em lavadora ultrassônica (US) por três sessões de 5 segundos cada e, consecutivamente, agitado por 5 minutos para complementar a extração da carga microbiana potencialmente presente na superfície dos materiais (externa e internamente). Em seguida, os lavados foram divididos em três partes iguais e submetidos à filtração em filtro Millipore® de 0,45 µm. Cada membrana foi cultivada em meio apropriado para o crescimento aeróbio, anaeróbio e fungos/leveduras. Para a identificação dos micro-organismos, foram utilizados kits e testes de identificação utilizados na rotina laboratorial de microbiologia clínica. Os resultados demonstraram que os três diferentes potenciais de contaminação apresentaram crescimento microbiano. Nas cirurgias limpas, 47% do instrumental estavam contaminados e o micro-organismo mais prevalente foi o Staphylococcus coagulase negativa (28%), seguido do Bacillus subtilis (11%). Nas cirurgias contaminadas e infectadas, houve um crescimento, de aproximadamente, 70% e 80%, respectivamente nos instrumentos, sendo maior o crescimento do Staphylococcus coagulase negativa (respectivamente, 32% e 29%) e Staphylococcus aureus (respectivamente, 28% e 43%). Considerando que os gêneros Bacillus e o Clostridium são capazes de esporularem, concluiu-se que a CME enfrenta um desafio ao precisar eliminar micro-organismos capazes de esporular, em uma densidade 102 UFC, menor que a dos indicadores biológicos e, aproximadamente, 78% dos micro-organismos recuperados foram bactérias vegetativas com sua curva de morte em torno de 80 ºC / The failure in orthopedic surgical procedures due to infection can lead to devastating consequences such as the loss of implanted prostheses. Hospital infection is an outcome with a multifactorial cause, in which the safe sterilization of the surgical instruments has an extremely important role. To date, it is not known what microbiological challenges the Material and Sterilization Center (MSC) has been facing when reprocessing the variety of materials used during these surgical procedures. Are microorganisms with the capacity to sporulate present in significant quantity and frequency? It is known that these microorganisms constitute a measurable challenge in sterilization practice and that they are part of the biological indicators. This study aimed at measuring the microbial load recovered from surgical instruments after their use in orthopedic surgeries, quantifying and identifying the genus and species of the bacterial and fungal growth. The study was characterized as an exploratory research, field research and cross-sectional with quantitative approach. The samples were collected at the Institute of Orthopedics and Traumatology (IOT) of Hospital das Clínicas (HC) of the School of Medicine of the University of São Paulo (FMUSP), using an aseptic technique, the samples were then placed in a plastic bag that had been previously sterilized with 500 mL of injection solution. To obtain the microbial load, the instruments were sonicated in an ultrasonic (US) washer for three 5-second sessions each and consecutively agitated for 5 minutes to complement the extraction of the microbial load potentially present on the surface of the materials (external and internally). Subsequently, the washed samples were fragmented in three equal parts and these were submitted to filtration in a 0.45 µm Millipore® filter. Each membrane was cultured in medium adequate for the growth of aerobic and anaerobic organisms, as well as fungi and yeasts. The identification of the microorganisms was carried out with identification kits and tests used in clinical microbiology laboratory routine. The results demonstrated that the three different contamination potentials presented microbial growth. In clean surgeries, 47% of the instruments were contaminated and the most prevalent microorganism was coagulase-negative Staphylococcus (28%) followed by Bacillus subtilis (11%). In contaminated and infected surgeries, a growth of approximately 70% and 80%, respectively, was identified in the instruments, with the higher growth being that of coagulase-negative Staphylococcus (respectively, 32% and 29%) and Staphylococcus aureus (respectively, 28% and 43%). Considering that the Bacillus and the Clostridium genera are capable of sporulating, we concluded that the MSC faces a challenge in having to eliminate microorganisms capable of sporulating, although in a lower density than that of biological indicators (102 UFC) and, approximately, 78% of the recovered microorganisms were vegetative bacteria that presented their curve of death at around 80ºC
4

Análise da carga microbiana nos instrumentos utilizados em cirurgias ortopédicas / Analysis of the microbial load in the instruments used in orthopedic surgeries

Flávia Morais Gomes Pinto 29 April 2009 (has links)
O insucesso nos procedimentos cirúrgicos ortopédicos em razão de infecção pode levar a consequências desastrosas como a osteomielite e a perda de próteses implantadas. A infecção hospitalar é um desfecho de causa multifatorial, na qual a esterilização segura do instrumental cirúrgico ocupa uma posição de extrema importância. Não se sabe até o momento quais os reais desafios microbiológicos que a Central de Material e Esterilização (CME) vem enfrentando ao reprocessar a diversidade dos materiais utilizados nos procedimentos cirúrgicos. Micro-organismos com capacidade para esporular estão presentes em quantidade e frequência significativa? Sabe-se que estes se constituem como desafio mensurável na prática da esterilização, fazendo parte de indicadores biológicos. O objetivo desta pesquisa foi determinar e analisar a carga microbiana recuperada do instrumental cirúrgico, após uso em cirurgias ortopédicas, quantificando e identificando o gênero e a espécie do crescimento de bactérias e fungos. A investigação caracterizou-se como uma pesquisa exploratória, de campo e transversal com abordagem quantitativa. As amostras foram coletadas no Instituto de Ortopedia e Traumatologia (IOT) do Hospital das Clínicas (HC) da Faculdade de Medicina da Universidade de São Paulo (FMUSP), com técnica asséptica, depositando-as individualmente em um saco plástico previamente esterilizado, adicionando 500 mL de água de injeção. Para obtenção da carga microbiana, o instrumental foi sonicado em lavadora ultrassônica (US) por três sessões de 5 segundos cada e, consecutivamente, agitado por 5 minutos para complementar a extração da carga microbiana potencialmente presente na superfície dos materiais (externa e internamente). Em seguida, os lavados foram divididos em três partes iguais e submetidos à filtração em filtro Millipore® de 0,45 µm. Cada membrana foi cultivada em meio apropriado para o crescimento aeróbio, anaeróbio e fungos/leveduras. Para a identificação dos micro-organismos, foram utilizados kits e testes de identificação utilizados na rotina laboratorial de microbiologia clínica. Os resultados demonstraram que os três diferentes potenciais de contaminação apresentaram crescimento microbiano. Nas cirurgias limpas, 47% do instrumental estavam contaminados e o micro-organismo mais prevalente foi o Staphylococcus coagulase negativa (28%), seguido do Bacillus subtilis (11%). Nas cirurgias contaminadas e infectadas, houve um crescimento, de aproximadamente, 70% e 80%, respectivamente nos instrumentos, sendo maior o crescimento do Staphylococcus coagulase negativa (respectivamente, 32% e 29%) e Staphylococcus aureus (respectivamente, 28% e 43%). Considerando que os gêneros Bacillus e o Clostridium são capazes de esporularem, concluiu-se que a CME enfrenta um desafio ao precisar eliminar micro-organismos capazes de esporular, em uma densidade 102 UFC, menor que a dos indicadores biológicos e, aproximadamente, 78% dos micro-organismos recuperados foram bactérias vegetativas com sua curva de morte em torno de 80 ºC / The failure in orthopedic surgical procedures due to infection can lead to devastating consequences such as the loss of implanted prostheses. Hospital infection is an outcome with a multifactorial cause, in which the safe sterilization of the surgical instruments has an extremely important role. To date, it is not known what microbiological challenges the Material and Sterilization Center (MSC) has been facing when reprocessing the variety of materials used during these surgical procedures. Are microorganisms with the capacity to sporulate present in significant quantity and frequency? It is known that these microorganisms constitute a measurable challenge in sterilization practice and that they are part of the biological indicators. This study aimed at measuring the microbial load recovered from surgical instruments after their use in orthopedic surgeries, quantifying and identifying the genus and species of the bacterial and fungal growth. The study was characterized as an exploratory research, field research and cross-sectional with quantitative approach. The samples were collected at the Institute of Orthopedics and Traumatology (IOT) of Hospital das Clínicas (HC) of the School of Medicine of the University of São Paulo (FMUSP), using an aseptic technique, the samples were then placed in a plastic bag that had been previously sterilized with 500 mL of injection solution. To obtain the microbial load, the instruments were sonicated in an ultrasonic (US) washer for three 5-second sessions each and consecutively agitated for 5 minutes to complement the extraction of the microbial load potentially present on the surface of the materials (external and internally). Subsequently, the washed samples were fragmented in three equal parts and these were submitted to filtration in a 0.45 µm Millipore® filter. Each membrane was cultured in medium adequate for the growth of aerobic and anaerobic organisms, as well as fungi and yeasts. The identification of the microorganisms was carried out with identification kits and tests used in clinical microbiology laboratory routine. The results demonstrated that the three different contamination potentials presented microbial growth. In clean surgeries, 47% of the instruments were contaminated and the most prevalent microorganism was coagulase-negative Staphylococcus (28%) followed by Bacillus subtilis (11%). In contaminated and infected surgeries, a growth of approximately 70% and 80%, respectively, was identified in the instruments, with the higher growth being that of coagulase-negative Staphylococcus (respectively, 32% and 29%) and Staphylococcus aureus (respectively, 28% and 43%). Considering that the Bacillus and the Clostridium genera are capable of sporulating, we concluded that the MSC faces a challenge in having to eliminate microorganisms capable of sporulating, although in a lower density than that of biological indicators (102 UFC) and, approximately, 78% of the recovered microorganisms were vegetative bacteria that presented their curve of death at around 80ºC