• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 856
  • Tagged with
  • 856
  • 856
  • 684
  • 564
  • 240
  • 224
  • 217
  • 180
  • 179
  • 166
  • 143
  • 135
  • 120
  • 103
  • 101
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
251

Validação de método para determinação de ácidos graxos voláteis em efluentes de biorreatores anaeróbios através de cromatografia gasosa

Rodrigues, Roberta Milena Moura 19 June 2017 (has links)
Submitted by Jean Medeiros (jeanletras@uepb.edu.br) on 2018-05-18T14:20:50Z No. of bitstreams: 1 PDF - Roberta Milena Moura Rodrigues.pdf: 36710948 bytes, checksum: 554ab863304bbf43e3ca861642fc5611 (MD5) / Made available in DSpace on 2018-05-18T14:20:51Z (GMT). No. of bitstreams: 1 PDF - Roberta Milena Moura Rodrigues.pdf: 36710948 bytes, checksum: 554ab863304bbf43e3ca861642fc5611 (MD5) Previous issue date: 2017-06-19 / onselho Nacional de Desenvolvimento Científico e Tecnológico - CNPq / Secondary biological anaerobic processes used for wastewater treatment have developed rapidly since the mid-20th century and are currently used in most Sewage Treatment Plants (ETEs) around the world. Sludge produced throughout the treatment is the main byproduct and is a semi-solid material containing organic matter, pathogenic microorganisms, toxic substances and even heavy metals withdrawn from the liquid phase. However, by applying appropriate treatment, it can transform itself from a problem residue into a product with economic value: modern and low-cost technologies can be reused in the material (nutrients and heavy metals) and its energy potential (biogas production - 70% methane). Volatile fatty acids (AGVs) are important intermediates of anaerobic digestion and their rate of production largely determines the rate of methane production. The knowledge of the concentration of VFAs in the sludge under treatment allows monitoring the performance of the reactor. The gas chromatography coupled to mass spectrometry (GC / MS), for the determination of VFAs, stands out from others for being efficient and selective, and allows structural information, molar mass, among other advantages. The validation of a method for its detection ensures the reliability of the results. In the present work, the Thermo Scientific gas chromatograph (TRACE 1300) was used and the detector was a Thermo Scientific mass spectrometer (ISQ QD - Single Quadrupole) with an SPB-624 intermediate polarity column. Recognized brand reagents And previous tests were done to define suitable conditions for the method (CG / MS). Validation was done following the recommendations of INMETRO and ANVISA. The results showed that the validation of the method (GC / MS) for determination of VFAs with the chosen column and the best chromatographic conditions obtained were adequate, taking into account the validation parameters: linearity (r ≥ 0,9843), precision Coefficients of variation <20%), sensitivity (angular coefficients ≥ 238218), limit of detection (0.030 mg.L-1 - 0.848 mg.L-1), limit of quantification (0.120 mg.L-1 - 2.827 mg.L -1), accuracy (100% - 110% - higher concentrations). Applied to real matrices, the method proved to be satisfactory because the retention times were very similar to the patterns used. / Processos biológicos secundários anaeróbios empregados para o tratamento de águas residuais têm se desenvolvidos de forma acelerada a partir da metade do século XX e são atualmente utilizados na maioria das Estações de Tratamento de Esgotos (ETEs) ao redor do mundo. Lodos produzidos ao longo do tratamento são o principal subproduto e constituem um material semisólido que contem matéria orgânica, microrganismos patogênicos, substâncias tóxicas e até metais pesados retirados da fase líquida. Entretanto, aplicando-se tratamento adequado, pode se transformar de um resíduo problema em um produto com valor econômico: tecnologias modernas e de baixo custo podem ser reaproveitados materiais nele contido (nutrientes e metais pesados) e pelo seu potencial energético (produção de biogás - 70% de metano). Os ácidos graxos voláteis (AGVs) são importantes intermediários da digestão anaeróbia e sua taxa de produção determina em grande parte a taxa de produção de metano. O conhecimento da concentração de AGVs no lodo em tratamento permite acompanhar o desempenho do reator. O método de cromatografia gasosa acoplada à espectrometria de massas (CG/EM), para determinação de AGVs, se destaca de outros por ser eficiente e seletivo, e permite obter informação estrutural, massa molar, entre outras vantagens. A validação de um método para sua detecção assegura a confiança dos resultados. No presente trabalho foi utilizado o cromatógrafo gasoso Thermo Scientific (TRACE 1300) e o detector foi um espectrômetro de massas Thermo Scientific (ISQ QD – Single Quadrupole) com uma coluna de polaridade intermediária SPB- 624. Foram utilizados reagentes (analitos) de marca reconhecida e testes prévios foram feitos para definir condições adequadas para o método (CG/EM). A validação do mesmo foi realizada seguindo as recomendações de INMETRO e ANVISA. Os resultados mostraram que a validação do método (CG/EM) para determinação de AGVs com a coluna escolhida e as melhores condições cromatográficas obtidas mostraram-se adequadas, atendendo aos parâmetros de validação: linearidade (r ≥ 0,9843), precisão (coeficientes de variação < 20%), sensibilidade (coeficientes angulares ≥ 238218), limite de detecção (0,030 mg.L-1 - 0.848 mg.L-1) , limite de quantificação (0.120 mg.L-1 - 2.827 mg.L -1), exatidão (100% - 110% - concentrações maiores). Aplicado em matrizes reais o método se mostrou satisfatório porque os tempos de retenção foram muito semelhantes aos dos padrões utilizados.
252

Dinâmica da comunidade fitoplanctônica em dois estuários tropicais sujeitos a diferentes usos do solo: Estuários Paraíba e Mamanguape

Santana, Rosa Maria da Costa 15 February 2018 (has links)
Submitted by Jean Medeiros (jeanletras@uepb.edu.br) on 2018-06-15T13:08:14Z No. of bitstreams: 1 PDF - Rosa Maria da Costa Santana.pdf: 51961570 bytes, checksum: 5a2038497b3a26e2cb0310104f961367 (MD5) / Approved for entry into archive by Secta BC (secta.csu.bc@uepb.edu.br) on 2018-06-18T18:13:01Z (GMT) No. of bitstreams: 1 PDF - Rosa Maria da Costa Santana.pdf: 51961570 bytes, checksum: 5a2038497b3a26e2cb0310104f961367 (MD5) / Made available in DSpace on 2018-06-18T18:13:01Z (GMT). No. of bitstreams: 1 PDF - Rosa Maria da Costa Santana.pdf: 51961570 bytes, checksum: 5a2038497b3a26e2cb0310104f961367 (MD5) Previous issue date: 2018-02-15 / The phytoplankton community is composed of microorganisms that are excellent environmental bioindicators, since they respond quickly to environmental disturbances. In this sense, the study aimed to apply diversity indexes (taxonomic and functional), as well as to explore the functional groups along the environmental gradients of two estuaries (Paraíba and Mamanguape) in two seasonal periods (dry = November/2013 and wet = July/2014) and to relate to the physical and chemical variables of water, in order to understand how this community responds to the different environmental and seasonal conditions. Thus, in the 1st chapter, the taxonomy of the Chlorophyta group was verified, since this group was the second most representative in this study. In estuarine environments, these green algae are common in low salinity, especially in periods of less rainfall and in the upstream segments. Twelve taxa were divided into two classes, three orders and 11 genera. In the 2nd chapter we compare the phytoplankton community's responses in terms of structure (abundance, richness and diversity) in relation to the environmental variables in estuaries with different uses and occupation of the soil. Biomass and abundance were higher when nutrient loads were higher, contributing to low diversity and dominance of the species Cyclotella meneghiniana, Thalassionema nitzschioides and Thalassiosira gravida associated to the different degrees of impacts observed in both ecosystems and seasonal periods. In the 3rd chapter, functional complementarity (CWM), redundancy and functional composition indexes (functional richness, functional diversity and quadratic entropy of RAO) were analyzed through functional groups based on combinations of different traits. In both systems, the main dominant functional group was diatoms, characterized by lack of mobility and high sink rates due to siliceous walls, including small and larger individuals, and freshwater to more cosmopolitan species. The presence of this group and the change in the categories of traces along the spatial and seasonal gradient were associated with the environmental condition, for example, river flow, low light conditions and changes in salinity. Overall, this study combining different approaches to taxonomic and functional diversity has improved our understanding of the changes occurring in both estuaries, pointing to efforts that should be directed towards more effective conservation measures that can be used in conservation programs systems. / A comunidade fitoplanctônica é composta por microorganismos que são excelentes bioindicadores ambientais, uma vez que respondem rapidamente às perturbações ambientais. Nesse sentido, o estudo objetivou aplicar índices de diversidade (taxonômico e funcional), como também explorar os grupos funcionais ao longo dos gradientes ambientais de dois estuários (Paraíba e Mamanguape), em dois períodos sazonais (seco = novembro/2013 e chuvoso = julho/2014) e relacionar com as variáveis físicas e químicas da água, visando compreender como essa comunidade responde às diferentes condições ambientais e sazonais. Assim, no 1°capítulo foi verificado a taxonomia relativa ao grupo das Chlorophytas, uma vez que esse grupo foi o segundo mais representativo nesse estudo. Em ambientes estuarinos, essas algas verdes são comuns em baixa salinidade, principalmente, em períodos de menos chuvas e nos segmentos mais a montante. Foram identificados 12 taxa distribuídos em duas classes, três ordens e 11 gêneros. No 2° capítulo comparamos as respostas da comunidade fitoplanctônica em termos de estrutura (abundância, riqueza e diversidade) em relação às variáveis ambientais em estuários com diferentes usos e ocupação do solo. A biomassa e abundância foram superiores quando as cargas de nutrientes estiveram mais elevadas, contribuindo para uma baixa diversidade e dominância da espécie Cyclotella meneghiniana, Thalassionema nitzschioides e Thalassiosira gravida associadas aos diferentes graus de impactos observados nos dois ecossistemas e aos períodos sazonais. No 3° capítulo foram avaliados índices de complementaridade funcional (CWM), redundância e composição funcional (riqueza funcional, diversidade funcional e entropia quadrática de RAO) analisados através de grupos funcionais baseados em combinações de diferentes traços. Em ambos os sistemas, o principal grupo funcional dominante foi o das diatomáceas, caracterizadas pela falta de mobilidade e altas taxas de afundamento devido às paredes silicosas, e incluindo indivíduos pequenos e maiores, e de água doce a espécies mais cosmopolitas. A presença deste grupo e a mudança nas categorias de traços ao longo do gradiente espacial e sazonalmente foram associadas à condição ambiental, por exemplo, escoamento do rio, condições de pouca luz e mudanças de salinidade. No geral, este estudo combinando diferentes abordagens de diversidade taxonômica e funcional, permitiu melhorar nossa compreensão das mudanças que ocorrem em ambos os estuários, apontando para esforços que devem ser dirigidos em relação à medidas de conservação mais eficazes e que podem ser utilizados em programas de monitoramento desses sistemas.
253

Restauração de água eutrofizadas do semiárido brasileiro através da técnica Flock & Lock

Silva, Daniely de Lucena 31 August 2018 (has links)
Submitted by Jean Medeiros (jeanletras@uepb.edu.br) on 2018-10-23T13:26:36Z No. of bitstreams: 1 PDF - Daniely de Lucena Silva.pdf: 19787731 bytes, checksum: 4876e7607977a002cf59f1f8d2f5d9a8 (MD5) / Made available in DSpace on 2018-10-23T13:26:36Z (GMT). No. of bitstreams: 1 PDF - Daniely de Lucena Silva.pdf: 19787731 bytes, checksum: 4876e7607977a002cf59f1f8d2f5d9a8 (MD5) Previous issue date: 2018-08-31 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / The Flock & Lock technique was indicated as one of the best alternatives for the recovery of eutrophicated lakes and reservoirs. This is a series of applications of flocculants (Flock) and clays (Lock) to flocculate / sediment and inactive, respectively, the phosphorus of the water column. The present study evaluated the efficiency of aluminum sulphate (SUL), alkali polychloride (PAC) and chitosan (QUI) flocculants, isolated and combined with natutal (BEN) and lanthanum modified bentonite (BML) eutrophic dust from the Brazilian semiarid, as well as the beneficial effects on cyanobacteria density and the intra and extracellular forms of cyanotoxins. Bench scale tests using water samples from the Argemiro Figueiredo reservoir, located in the municipality of Itatuba, Paraíba, Brazil. These tests were conducted in glass beakers containing 200 mL of water from the reservoir, samples being collected at the top and bottom of the beakers. Cyanobacteria density was determined by inverted microscope and the intra and extracellular concentrations of the cyanotoxins microcystin, saxitoxin and cylindrospermopsin by the Enzyme-Linked Immuno Sorbent Assay (ELISA) method. Analysis of one-way variance (ANOVA one-way) was performed to verify significant differences between treatments. It was observed that the SUL and PAC flocculants efficiently reduced the PT, PSR, turbidity, chlorophyll-a, cyanobacteria density and intracellular microcystin efficiency, whereas the chitosan showed low removal power of the evaluated parameters. The BML showed to be more efficient than the BEN, however, the application of these clays combined with the flocculants was not strictly necessary in the success of the Flock & Lock technique, since the SUL and PAC alone proved to be sufficient in the significant removal of the parameters studied. The efficiency of flocculants in the removal of cyanobacteria cells varied between species. Small-sized species such as A. delicatissima, M. glauca and M. tenuissima were effectively removed regardless of treatment, including those with QUI and BEN, while filamentous cyanobacteria C. raciborskii, G. amphibium, P. agardhii and P. Catenata were removed only with the application of PAC, SUL and BML isolated and combined. The intracellular concentrations of saxitoxin and cylindrospermopsin and the extracellular fraction of these cyanotoxins and microcystin were not influenced by the application of flocculants and clays. These results show that cyanotoxin types differ in the response to these compounds and that the successful application of the Flock & Lock technique in the recovery of eutrophic lakes and reservoirs can be compromised in bodies of water with high concentration of dissolved toxins. / A técnica Flock & Lock tem sido indicada como uma das melhores alternativas na recuperação de lagos e reservatórios eutrofizados. Essa técnica consiste na aplicação de floculantes (Flock) e argilas (Lock) para flocular/sedimentar e inativar, respectivamente, o fósforo da coluna d‟água. O objetivo do presente estudo foi avaliar a eficiência dos floculantes sulfato de alumínio (SUL), policloreto de alimínio (PAC) e quitosana (QUI), isolados e combinados com argilas betonita natutal (BEN) e bentonita modificada com lantânio (BML), na remoção do P em águas eutrofizadas do semiárido brasileiro, bem como verificar os efeitos desses compostos sobre a densidade das cianobactérias e as concentrações intra e extracelular das cianotoxinas. Ensaios em escala de bancada foram realizados utilizando amostras da água do reservatório Argemiro Figueiredo, localizado no município de Itatuba, Paraíba, Brasil. Esses ensaios foram conduzidos em provetas de vidro contendo 200 mL da água do reservatório, sendo coletadas amostras no topo e fundo das provetas. A densidade das cianobactérias foi determinada em microscópio invertido e as concentrações de intra e extracelular das cianotoxinas microcistina, saxitoxina e cilindrospermopsina pelo método Enzyme-Linked Immuno Sorbent Assay (ELISA). A análise de variância um fator (ANOVA um fator) foi realizada para verificar as diferenças significativas entre os tratamentos. Foi observado que os floculantes SUL e PAC reduziram eficientemente da coluna d‟água o PT, PSR, turbidez, clorofila-a, densidade das cianobactérias e microcistina intracelular, enquanto a quitosana mostrou baixo poder de remoção dos parâmetros avaliados. A BML mostrou ter maior eficiência que a BEN, no entanto, a aplicação dessas argilas combinadas com os floculantes mostrou não ser estritamente necessária no sucesso da técnica Flock & Lock, uma vez que o SUL e PAC sozinhos mostraram ser suficientes na remoção significativa dos parâmetros estudados. A eficiência dos floculantes na remoção das células das cianobactérias variou entre as espécies. As espécies de pequeno tamanho como A. delicatissima, M. glauca e M. tenuissima foram eficazmente removidas independente do tratamento, incluindo aqueles com a QUI e a BEN, enquanto as cianobactérias filamentosas C. raciborskii, G. amphibium, P. agardhii e P. catenata foram removidas apenas com a aplicação do PAC, SUL e BML isolados e combinados. As concentrações intracelulares da saxitoxina e cilindrospermopsina e a fração extracelular dessas cianotoxinas e da microcistina não foram influenciadas pela aplicação dos floculantes e argilas. Esses resultados mostram que os tipos de cianotoxinas diferem na resposta a esses compostos e que o sucesso da aplicação da técnica Flock & Lock na recuperação de lagos e reservatórios eutrofizados pode ser comprometida em corpos d‟água com alta concentração de toxinas dissolvidas.
254

Viabilidade econÃmica do aproveitamento do biogÃs de pequenos aterros sanitÃrios na reciclagem de plÃstico / Economic viability of small landfill biogas exploitation in plastic recycling

Fernando Henrique Ribeiro Holanda 06 June 2014 (has links)
CoordenaÃÃo de AperfeÃoamento de Pessoal de NÃvel Superior / A geraÃÃo de resÃduos sÃlidos faz parte do contexto social em que vivemos, entretanto, a cultura da reciclagem ainda à pouco valorizada no Brasil. A PolÃtica Nacional de ResÃduos SÃlidos, de 2010, estimula a valorizaÃÃo do processo de reciclagem, da organizaÃÃo e do fim da informalidade dos catadores, alÃm de incentivar o aproveitamento energÃtico do biogÃs gerado em aterros sanitÃrios. Fundamentado nesses trÃs pontos, o presente trabalho elaborou um plano de negÃcios para a implantaÃÃo de uma usina de reciclagem de plÃstico Polietileno de Alta Densidadeâ PEAD, utilizando, para tanto, a energia produzida pelo biogÃs no Aterro SanitÃrio Metropolitano Sul em MaracanaÃ, CearÃ. Foram desenvolvidos projetos de coleta e aproveitamento do biogÃs e de uma usina de processamento de PEAD, alÃm de levantamento de custos de todo o material necessÃrio para a implantaÃÃo e operaÃÃo da planta. Analisou-se a viabilidade econÃmica de dois ambientes distintos, pela Cooperativa de catadores e pela Empresa de reciclagem. Para cada ambiente, foram desenvolvidos trÃs cenÃrios de aquisiÃÃo do material plÃstico (100% comprado, 50% comprado e 50% doado, 100% doado). Foi possÃvel constatar que apenas o ambiente Cooperativa e o terceiro cenÃrio mostraram-se sustentÃveis para a implantaÃÃo de um sistema deste porte. / A geraÃÃo de resÃduos sÃlidos faz parte do contexto social em que vivemos, entretanto, a cultura da reciclagem ainda à pouco valorizada no Brasil. A PolÃtica Nacional de ResÃduos SÃlidos, de 2010, estimula a valorizaÃÃo do processo de reciclagem, da organizaÃÃo e do fim da informalidade dos catadores, alÃm de incentivar o aproveitamento energÃtico do biogÃs gerado em aterros sanitÃrios. Fundamentado nesses trÃs pontos, o presente trabalho elaborou um plano de negÃcios para a implantaÃÃo de uma usina de reciclagem de plÃstico Polietileno de Alta Densidadeâ PEAD, utilizando, para tanto, a energia produzida pelo biogÃs no Aterro SanitÃrio Metropolitano Sul em MaracanaÃ, CearÃ. Foram desenvolvidos projetos de coleta e aproveitamento do biogÃs e de uma usina de processamento de PEAD, alÃm de levantamento de custos de todo o material necessÃrio para a implantaÃÃo e operaÃÃo da planta. Analisou-se a viabilidade econÃmica de dois ambientes distintos, pela Cooperativa de catadores e pela Empresa de reciclagem. Para cada ambiente, foram desenvolvidos trÃs cenÃrios de aquisiÃÃo do material plÃstico (100% comprado, 50% comprado e 50% doado, 100% doado). Foi possÃvel constatar que apenas o ambiente Cooperativa e o terceiro cenÃrio mostraram-se sustentÃveis para a implantaÃÃo de um sistema deste porte. / The generation of solid waste is part of the social context in which we live , however, the culture of recycling is still undervalued in Brazil . The 2010 National Solid Waste Policy encourages the improvement of recycling process, the organization of waste pickers to end informal activities, and encourages the use of biogas generated in landfills. Based on these three topics, this paper drew up a business plan for a recycling plant for HDPE using the biogas energy produced in the South Metropolitan Landfill in Maracanau, CearÃ. For this, a biogas collection system and a plant for HDPE processing were developed in addition costs estimates of all the material needed for their implementation and operation. It was analyzed the economic feasibility for two distinct environments, using the waste pickers Cooperative and through a regular recycling company. For each environment, three raw material acquisition scenarios were developed (100% purchased, 50 % purchased and 50% donated, and 100 % donated ). It was found that only with the cooperative environment and in the third scenario the business proved to be economically feasible. / The generation of solid waste is part of the social context in which we live, however, the culture of recycling is still undervalued in Brazil. The National Solid Waste Policy, 2010, encourages the enhancement of the recycling process, the organization and the end of the informal waste pickers, and encourage the energy use of biogas generated in landfills. Based on these three points, this study developed a business plan for the deployment of a plastic recycling plant in High Density Polyethylene HDPE, using for this purpose, the energy produced by biogas in South Metropolitan Landfill in Marazion, CearÃ. Were developed collection of projects and use of biogas and a HDPE processing plant, as well as raising costs of all the material necessary for the implementation and operation of the plant. We analyzed the economic feasibility of two different environments, by the Cooperative pickers and recycling by the Company. For each environment, were developed three scenarios for the acquisition of the plastic material (100% purchased, 50% purchased and donated 50%, 100% donated). It was found that only the cooperative environment and the third scenario proven to be sustainable for the implementation of a system of this size.
255

Qualidade da água dos reservatórios situados na bacia hidrográfica dos rios Piauí – Real : uma avaliação com base em técnicas estatísticas multivariadas e razões iônicas

Lima, Robson Silva de 31 March 2015 (has links)
In this work the quality of the water and its variations were evaluated for the Dionísio Machado (DM), Taboca (TB), Amargosa (AG) and Jabiberi (JB) reservoirs, located in the South Central region of the State of Sergipe. Surface water samples were collected in three sampling campaigns, two in the rainy season and one in the dry period, included between June 2013 and August 2014. In each sample the following parameters were determined: pH, electric conductivity, turbidity, dissolved oxygen, total alkalinity, hardness, biochemical oxygen demand, total dissolved solids, colour, total organic carbon, total phosphorus, nitrate, nitrite, ammoniacal nitrogen, phosphate, sodium, potassium, calcium, magnesium, chloride, sulphate, bicarbonate, thermotolerant coliforms and temperature. The principal component analysis, correlation analysis Spearman and cluster analysis were applied to all data, in order to compare the standard quality of the water between reservoirs and to obtain information about the differences between the dry and rainy seasons on the variables involved in discrimination and their origin sources. To the Dionísio and Taboca reservoirs, the samples collected during the rainy season of 2014 showed similarity to those collected in the 2013 dry season and difference from samples collected in the rainy season of 2013. While for Jabiberi reservoir, all samples were similar, no difference was observed in the dry and rainy period. The sample of Amargosa showed no similarity to any sample of the remaining reservoirs and it could not be verified a seasonal variation, since for this reservoir, a single sample was collected in the rainy season of 2013. Through the principal component analysis, we found that the salinization is the main process that explains the variations in the quality of the water in the reservoirs. The electrical conductivity of the samples ranged from 0.160 to 4.175 dS m-1, showing a growing process of salinization, reaching a maximum value in the Amargosa reservoir. Through the ionic fractions it was possible to infer that the main factors that control the process of the reservoir water salinity are of natural origin and are associated with the cation exchange reactions and subsequent dissolution of soluble minerals such as halite, gypsum and possibly epsomita. / Nesse trabalho foram avaliadas a qualidade da água e suas variações, para os reservatórios Dionísio Machado (DM), Tabocas (TB), Amargosa (AG) e Jabiberi (JB), situados na região Centro Sul do Estado de Sergipe. Amostras de água de superfície foram coletadas em três campanhas de amostragem, duas no período chuvoso e uma no período seco, compreendidas no intervalo temporal de junho de 2013 a agosto de 2014. Em cada amostra foram determinados os seguintes parâmetros: pH, condutividade elétrica, turbidez, oxigênio dissolvido, alcalinidade total, dureza, demanda bioquímica de oxigênio, sólidos totais dissolvidos, cor, carbono orgânico total, fosfato, fósforo total, nitrato, nitrito, nitrogênio amoniacal, sódio, potássio, cálcio, magnésio, cloreto, sulfato, bicarbonato, coliformes termotolerantes e temperatura. A análise de componentes principais, a análise de correlação de Spearman e a análise de agrupamento foram aplicadas ao conjunto dos dados, com objetivo de comparar o padrão de qualidade da água entre os reservatórios e obter informações sobre as diferenças entre os períodos seco e chuvoso, sobre as variáveis envolvidas na discriminação e as fontes que a originaram. As amostras coletadas no período chuvoso de 2014 mostraram similaridade com as amostras coletadas no período seco de 2013 e diferentes das amostras coletadas no período chuvoso de 2013, para os reservatórios de Taboca e Dionísio. Enquanto que para o reservatório de Jabiberi, todas as amostras foram similares, não se observando diferença em relação ao período seco e chuvoso. A amostra de Amargosa não mostrou similaridade com nenhuma amostra dos outros reservatórios e não foi possível verificar variação com a sazonalidade, pois, para esse reservatório, foi coletada uma única amostra no período chuvoso de 2013. Pela análise de componentes principais foi possível identificar que a salinização é o principal processo que explica as variações na qualidade da água dos reservatórios. A condutividade elétrica das amostras variou de 0,160 a 4,175 dS m-1, mostrando um processo crescente de salinização, atingindo um valor máximo no reservatório de Amargosa. Através das razões iônicas foi possível inferir que os principais fatores que controlam o processo de salinização da água dos reservatórios são de origem natural e estão associados às reações de troca catiônica e posterior dissolução de minerais solúveis como halita, gipsita e possivelmente epsomita.
256

Tratamento do lodo de resíduos de fossas e tanques sépticos em um sistema de alagado construído / Septic tanks and cesspools residues sludge treatment at a constructed wetlands system

Silva Junior, Édio Damásio da 13 November 2013 (has links)
Submitted by Erika Demachki (erikademachki@gmail.com) on 2014-10-23T16:36:45Z No. of bitstreams: 2 Dissertação - Édio Damásio da Silva Junior - 2013.pdf: 3273647 bytes, checksum: 8b91152a8caeed706b4e8d78ff9facc0 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Approved for entry into archive by Jaqueline Silva (jtas29@gmail.com) on 2014-10-23T18:07:43Z (GMT) No. of bitstreams: 2 Dissertação - Édio Damásio da Silva Junior - 2013.pdf: 3273647 bytes, checksum: 8b91152a8caeed706b4e8d78ff9facc0 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Made available in DSpace on 2014-10-23T18:07:43Z (GMT). No. of bitstreams: 2 Dissertação - Édio Damásio da Silva Junior - 2013.pdf: 3273647 bytes, checksum: 8b91152a8caeed706b4e8d78ff9facc0 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Previous issue date: 2013-11-13 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / The use of individual systems for treatment and disposal of sewage (ISTDS) comes as an option to the lack of sanitation in many Brazilian regions, mainly in small settlements. However, the wastes generated in these systems represent another health problem, since it contains high levels of pathogens and organic load. These wastes, termed septic tanks and cesspools residues (STCR) must be treated before their disposal to the environment. Simple and low cost technologies, like the constructed wetlands systems (CW), should be developed and evaluated aiming its implementation in small population centers. This study aimed to evaluate the treatment, more specifically the cleaning and stabilization, of the sludge accumulated in a CW designed to treat STCR. Two tanks were constructed, dug into the ground and filled with overlapping layers of gravel and sand for application and treatment of the STCR. One of them was grown by the vegetal specie Vetiver Grass (Chrysopogon zizanioides) and the other one was used as a control treatment. The STCR were applied to the system by the exhaustion of clean-pit trucks. The system behaved in vertical downward subsurface flow, controlled by a fluid spilling system. Physical-chemical and microbiological analyses of the crude residue and sludge in treatment in both tanks were made. The STCR nutritional potential was characterized through the determination of total phosphorus, total, organic and ammonia nitrogen, nitrite and nitrate. Their pathogen load was characterized by counting total coliforms, Escherichia coli, Salmonella spp. and helminths viable eggs. In addition, were characterized the attributes pH, moisture, total, volatile and fixed solids. From the sludge accumulated on the surface of treatment beds they were evaluated its pathogen load, solids content and moisture. The results were compared with the established pursuant to resolution nº 375/2006, of the brazilian National Council for the Environment (CONAMA), to verify the possibility of the sludge use in agriculture. The crude residue characterization results, showed to be similar to those cited by the literature, with high concentrations of pathogens and nutrients and also, high dispersion of values. With STCR disposals, the sludge layer increased in both systems, with higher values for the CW (about 1.1 cm per month), because of their greater capacity to retain moisture. During the disposal phase, both tanks sludge remained with high values of pathogenic organisms. At the end of the applications, there has been considerable reduction of these values, suggesting that for a better sludge treatment should be a period of "rest" without applications. It was observed that after two months of "rest", the sludge from both tanks was framed in A Class, with potential use in agriculture, as standardizes the resolution nº 375/2006 of CONAMA. In general, the tank without plants showed greater speed in the process of cleaning the sludge than the CW, mainly due to the direct sunlight exposure. However, with respect to the stabilization process, the CW was better than the control tank. / A utilização de sistemas individuais de tratamento e disposição de esgoto (SITDE) constitui-se em opção à carência de saneamento básico em diversas regiões brasileiras, principalmente em pequenos núcleos populacionais. Todavia, os resíduos esgotados nestes sistemas representam novo problema sanitário, uma vez que contém elevados teores de organismos patogênicos e de carga orgânica. Estes resíduos, denominados de resíduos de fossas e tanques sépticos (RFTS), devem ser tratados antes de sua disposição no meio ambiente. Tecnologias simples e de baixos custos, como os sistemas de alagados construídos (SAC’s), devem ser desenvolvidas e pesquisadas visando sua implantação em pequenos núcleos populacionais. Este trabalho objetivou avaliar o tratamento, mais especificamente a higienização e estabilização, do lodo acumulado em um SAC projetado para tratamento de RFTS. Foram construídos dois tanques, escavados no solo e preenchidos com camadas sobrepostas de brita e areia para aplicação e tratamento dos RFTS. Um tanque foi cultivado com a espécie vegetal Capim Vetiver (Chrysopogon zizanioides) e o outro serviu de testemunha. Os RFTS foram aplicados através do esgotamento de caminhões limpa-fossa. O sistema comportou-se em fluxo subsuperficial vertical descendente, controlado por um sistema de extravazão de líquidos. Foram realizadas análises físico-químicas e microbiológicas do resíduo bruto e do lodo em tratamento de ambos os tanques. Caracterizou-se o potencial nutricional do RFTS por meio da determinação das concentrações de fósforo total, nitrogênio total, orgânico e amoniacal, nitrito e nitrato. A carga de patógenos foi obtida por meio da contagem de coliformes totais, Escherichia coli, Salmonella spp. e ovos viáveis de helmintos. Também foram caracterizados os atributos pH, umidade, sólidos totais, fixos e voláteis. Do lodo acumulado na superfície dos leitos de tratamento avaliaram-se a carga patógena, o teor de sólidos e a umidade. Os resultados foram comparados com o estabelecido pela resolução nº 375/2006, do Conselho Nacional de Meio Ambiente (CONAMA), para verificar sua potencialidade de uso agrícola. A caracterização do resíduo bruto apresentou dados similares à literatura, com elevadas concentrações de patógenos e nutrientes, além da alta dispersão de resultados. Com as disposições do RFTS, a camada de lodo aumentou em ambos os sistemas, com valores superiores para o SAC (cerca de 1,1 cm ao mês), em virtude de sua maior capacidade de retenção de umidade. Durante a fase de aplicação dos resíduos, o lodo de ambos os tanques permaneceu com altos valores de organismos patógenos. Ao cessar as aplicações, houve considerável redução destes valores, sugerindo que para melhor tratamento do lodo deve-se haver um período de “descanso”, sem aplicações. Observou-se que após um período de dois meses de “descanso”, o lodo de ambos os tanques foi enquadrado na classe A, com possibilidade de uso na agricultura, conforme normatiza o CONAMA. De forma geral, o tanque sem plantas apresentou maior rapidez no processo de higienização do lodo do que no SAC, principalmente em função da exposição solar direta. Entretanto, no que tange ao processo de estabilização, o SAC foi superior ao tanque controle.
257

Disposição de efluente de tratamento de esgoto industrial em solo vegetado com bambu / Industrial sewage treatment effluent disposal in soil vegetated with bamboo

MENDONÇA, Eurivan Alves 31 August 2010 (has links)
Made available in DSpace on 2014-07-29T15:01:44Z (GMT). No. of bitstreams: 1 Dissertacao Eurivan A Mendonca 2010.pdf: 356252 bytes, checksum: 182f4d4d579221f0db2469404dd75fd2 (MD5) Previous issue date: 2010-08-31 / This study aimed to evaluate the efficiency of the bamboo species Guadua angustifolia Kunth, Guadua chacoensis and Dendrocalamus giganteus Munro in the treatment of the Senador Canedo Industrial District Sewer Treatment effluent. It was analyzed diary effluent slides of 176.8, 212.2, 247.6 and 353.7 mm applied in individual 200 L drums filled with regional soil (oxisoil) and vegetated with bamboo. Drums without plants served as control. The effluent treated by the containers was analyzed for biochemical oxygen demand (BOD), dissolved oxygen, chemical oxygen demand (COD), apparent color, pH, ammonium nitrogen, phosphates, turbidity, chlorides, hardness, electrical conductivity, total solids, dissolved total solids, volatile total solids, fixed total solids and coliforms, during a five month period. The results were analyzed by Statistical Analysis System Program (SAS) through F test and Tukey-Kramer test (5% of probability). Treatment using bamboo were more efficient than control in removing BOD, COD, pH, dissolved oxygen, apparent color, total solids, fixed solids, coliforms, chlorides, turbidity, electrical conductivity, phosphates and ammonium nitrogen. Among vegetated drums, bamboos of Guadua gender were more efficient in removing BOD, COD, coliforms and volatile solids than units with D. giganteus. Application rates had no significant influence on treatment efficiencies. It was also evaluated the bamboo species under field conditions, submitted to a diary effluent slide of 353.7 mm for a period of one year. Samples of groundwater were collected to verify some resultant contamination from the effluent application. It wasn t observed groundwater contamination by applying effluent at soil vegetated with bamboo. / Este estudo objetivou avaliar a eficiência das espécies de bambu Guadua angustifolia Kunth, Guadua chacoensis e Dendrocalamus giganteus Munro, no tratamento do efluente da estação de tratamento de esgotos do Distrito Industrial de Senador Canedo, GO. Analisou-se a aplicação das lâminas diárias de efluente de 176,8; 212,2; 247,6 e 353,7 mm em tambores individuais de 200 Litros preenchidos com solo da região (latossolo vermelho distrófico) e vegetados com bambu. Tambores sem plantas serviram de testemunhas. O efluente tratado nos tambores foi analisado quanto à demanda bioquímica de oxigênio (DBO), oxigênio dissolvido, demanda química de oxigênio (DQO), cor aparente, pH, nitrogênio amoniacal, fosfatos, turbidez, cloretos, dureza, condutividade elétrica, sólidos totais, sólidos totais dissolvidos, sólidos totais voláteis, sólidos totais fixos e coliformes termotolerantes, por um período de cinco meses. Os resultados foram submetidos aos testes F e de Tukey-Kramer (5% de probabilidade). Os tratamentos com bambu foram mais eficientes na remoção dos parâmetros DBO, DQO, pH, oxigênio dissolvido, cor, sólidos totais, sólidos fixos, coliformes termotolerantes, cloretos, turbidez, condutividade elétrica, fosfatos e nitrogênio amoniacal que a testemunha sem planta. Os bambus do gênero Guadua foram mais eficientes na remoção de DBO, DQO, coliformes termotolerantes e sólidos voláteis que o tratamento com D. giganteus. Observou-se que as taxas de aplicação não tiveram influência significativa nas eficiências do tratamento. Também se avaliaram as espécies de bambu em condições de campo, submetidas à aplicação de uma lâmina diária de 353,7 mm de efluente por um período de um ano. Coletaram-se amostras da água do lençol freático com a finalidade de verificar a ocorrência de contaminação decorrente da aplicação do efluente. Não foi observada contaminação do lençol freático pela aplicação do efluente no solo vegetado com bambu.
258

Desenvolvimento de biossensor contendo polifenoloxidases de sementes de jatobá para análise ambiental / Developmento of biosensor containing polyphenoloxidase jatobá seed for environmental analysis

SANTIAGO, Patrícia de Oliveira 08 September 2011 (has links)
Made available in DSpace on 2014-07-29T15:01:46Z (GMT). No. of bitstreams: 1 Patricia de oliveira.pdf: 1196794 bytes, checksum: 976756f875036b0ad2be9a06533e333d (MD5) Previous issue date: 2011-09-08 / The polyphenoloxidase (PPO) is responsible for catalyzing the conversion of phenolic compounds to quinones in the presence of oxygen. This enzyme is widely used in biosensor production and selective evaluation of phenol content in industrial effluents. In this work a biosensor modified with enzyme extract containing polyphenoloxidase from Hymenaea stigonocarpa (jatoba) seed was developed to detect phenolic compounds. The extraction was performed using Structural Risk Minimization (SRM) factorial design with 22 more central point. The extraction conditions were optimized in 1.0% (w / v) polyvinylpyrrolidone (PVP) in 50 mmol l-1 phosphate buffer pH 7.5, time 40 min. The activity obtained was 0,97 ± 0,03 UEmg-1 proteins. The crude extract was partially purified using precipitation with ammonium sulfate 60% (w / v) and fractionated in phosphate buffer pH 7.0 in 1.0% Triton TX-100.The PPO activity resulting precipitated fraction was 2.7 times higher than in the crude extract. In 10% SDS gel were found six bands, three of which have molecular weights characteristic of PPO. The biosensor was constructed with a mixture of 60 mg of graphite powder, 30 mL of mineral oil and 10 mg of the enzymatic extract. The amperometric response was measured as the concentration of phenol, a voltage range of +0.13 - +0.38 V vs. SCE in phosphate buffer pH 7.0, the sweep speed in 100mVs-1. The electrode has a linear response range from 0.5 to 3.0 mol L-1 (r = 0.9981) using catechol as substrate. This biosensor was used to detect different types of phenolic compounds and when subjected to a sample of effluent from the pharmaceutical industry, no reading was obtained. / A polifenoloxidase (PPO) é responsável por catalisar a conversão de compostos fenólicos para quinonas na presença de oxigênio. Esta enzima é amplamente utilizada na produção de biossensores e avaliação seletiva de fenóis em efluentes industriais. Neste trabalho um biossensor modificado com extrato contendo enzima polifenoloxidase de sementes de Hymenaea stigonocarpa (jatobá) foi desenvolvido para detectar compostos fenólicos. A extração PPO foi realizada utilizando Minimização do Risco Estrutural (SRM) com desenho fatorial 22 mais ponto central. As condições de extração foram otimizadas em 1,0 % (m/v) de polivinilpirrolidona (PVP) em 50 mmolL-1 de tampão fosfato pH 7,5, no tempo de 40 min. A atividade obtida foi 0,97± 0,03 UEmg-1 de proteínas. O extrato bruto foi parcialmente purificado utilizando precipitação com sulfato de amônio 60% (m / v) e fracionado em tampão fosfato pH 7,0 em 1,0% Triton TX-100. A atividade da PPO resultante na fração precipitada foi de 2,7 vezes maior do que no extrato bruto. No gel de SDS 10% foram encontradas 6 bandas, das quais 3 possuem pesos moleculares característicos de PPO. O biossensor foi construído com uma mistura de 60 mg de pó de grafite, 30 &#956;L de óleo mineral e 10 mg do extrato enzimático parcialmente purificado. A resposta amperométrica foi medida em função da concentração de fenol, a uma faixa de voltagem de +0,13- +0,38 V vs SCE, em tampão fosfato pH 7,0, na velocidade de varredura em 100mVs-1. O eletrodo apresentou uma faixa de resposta linear de 0,5-3,0 molL-1 (r = 0,9981), utilizando catecol como substrato. Esse biossensor foi usado para a detecção de diferentes tipos de compostos fenólicos e quando submetido a uma amostra de efluente de industria farmacêutica. Não obteve-se leitura.
259

Tratamento de esgoto sanitário em sistemas alagados construídos utilizando Typha angustifolia e Phragmites australis / Sanitary sewer treatment in constructed wetlands system using Typha angustifolia and Phragmites australis

ABRANTES, Lorena Lemes Martins 28 August 2009 (has links)
Made available in DSpace on 2014-07-29T15:01:49Z (GMT). No. of bitstreams: 1 Dissertacao Lorena L M Abrantes.pdf: 4341681 bytes, checksum: 30126c561a517a7154d7108de137e004 (MD5) Previous issue date: 2009-08-28 / This study aimed to assess the efficiency of two vegetal species in the treatment of the sanitary sewer, in constructed wetlands system. Specifically, it aimed to evaluate the efficiency of the species Typha angustifolia (narrow-leaf cattail) and Phragmites australis (common reed), in their possible combinations, in the treatment of the sanitary sewer, in a constructed wetlands system, of vertical subsuperficial flux, with two flux directions (ascendant and descendant), related to the attributes: organic material, apparent color, ammonium nitrogen, phosphate, turbidity, chlorides, hardness, electrical conductivity, solids and thermotolerant coliforms. The experiment was conducted in the Researching Station in Sewer Treatment with Plants RSSTP (UFG), located in the Sewer Treatment Station (STS) Samambaia, in Goiânia, Goiás State, Brazil. The experimental unit has twenty four modules, grouped sequences of two modules (initial and final modules). Raw sewage which comes from the initial part of the ETE facultative pond was pumped into the deep of the treatment initial modules, filled up with substrate layers (in the deep filled up with rocks category number 3, followed by rocks category number 1, washed sand, and again rocks category number 1) and planted with cattail or reed. After going up by the vegetated substrate (ascendant vertical flux) the sewer was drained and conducted to the final treatment modules equally filled up and vegetated with one of the species, although being applied in the surface and drained by the deep (vertical descendant flux). The tax of sewer application was of 80 L.m-2dia-1, corresponding to a treatment area of 2 m2 per inhabitant. A year after the system implementation, during the period of 6 months, sewer samples were collected after passing through the flux sequences, each one with the combination of the two vegetal species, for the evaluation of the sewer attributes and calculation of the efficiency in the treatment. The results were analyzed by the Statistical Analysis System (SAS program), being used the tests F and the Tukey Kramer, considering 5% of probability. There were no meaningful differences in the efficiency of the treatments in the removal of the attributes: biochemical oxygen demand, chemical oxygen demand, ammonium nitrogen, phosphate, thermotolerant coliforms, chlorides, hardness, dissolved total solids and volatile total solids. The cattail was more efficient in the apparent color removal and turbidity. The reed presented more efficiency in the total solids removal. The position of the plant in the module sequence did not influence the apparent color and turbidity removals. The reed in the final module increased the removal of the attributes total solids and fixed total solids. It´s possible to verify that the technology of sewer treatment by using plants is efficient, since the species cattail and reed in the adopted system, provided results with removals higher 60% for the of the attributes: biochemical oxygen demand, chemical oxygen demand, apparent color, ammonium nitrogen, phosphate, thermotolerant coliforms and turbidity. / O presente estudo teve como objetivo avaliar a eficiência de duas espécies vegetais no tratamento do esgoto sanitário, em um sistema de alagados construídos. Especificamente, objetivou-se avaliar a eficiência das espécies Typha angustifolia (Taboa) e Phragmites australis (Caniço), em suas combinações possíveis, no tratamento de esgoto sanitário, em um sistema de alagados construídos, de fluxo subsuperficial vertical, com dois sentidos de fluxo (ascendente e descendente), concernente aos atributos: matéria orgânica, cor aparente, nitrogênio amoniacal, fosfato, turbidez, cloretos, dureza, condutividade elétrica, sólidos e coliformes termotolerantes. O experimento foi conduzido na Estação de Pesquisas em Tratamento de Esgotos com Plantas Eptep (UFG), localizada na Estação de Tratamento de Esgotos (ETE) Samambaia, em Goiânia, GO. A unidade experimental possui vinte quatro módulos, agrupados em sequências de dois módulos (módulos iniciais e finais). Esgoto sanitário bruto proveniente da parte inicial da lagoa facultativa da ETE foi bombeado no fundo de módulos iniciais de tratamento preenchidos com camadas sobrepostas de substrato (no fundo com brita número 3, na sequência brita número 1, areia lavada e novamente brita número 1) e plantados com taboa ou caniço. Após subir pelo substrato vegetado (fluxo vertical ascendente) o esgoto era drenado e conduzido aos módulos finais de tratamento, igualmente preenchidos e vegetados com uma das espécies, todavia sendo aplicado na superfície e drenado pelo fundo (fluxo vertical descendente). A taxa de aplicação de esgoto foi de 80 L.m-2dia-1, correspondendo a uma área de estação de tratamento de 2 m2 por habitante. Um ano após a implantação do sistema, por um período de seis meses, amostras do esgoto foram coletadas após passar pelas sequências de fluxo, cada uma com uma combinação das duas espécies vegetais, para avaliação dos teores de atributos do esgoto e cálculo da eficiência do tratamento. Os resultados foram analisados pelo programa Statistical Analysis System (SAS), realizando-se os testes F e de Tukey Kramer, a 5% de probabilidade. Não houve diferença significativa entre as eficiências dos tratamentos na remoção dos atributos: demanda bioquímica de oxigênio, demanda química de oxigênio, nitrogênio amoniacal, fosfatos, coliformes termotolerantes, cloretos, dureza, sólidos totais dissolvidos e sólidos totais voláteis. A taboa foi mais eficiente na remoção da cor aparente e da turbidez. Já o caniço apresentou uma eficiência maior na remoção de sólidos totais. A posição da planta na sequência de módulos não influenciou na remoção da cor aparente e da turbidez. O caniço no módulo final influenciou positivamente na remoção dos atributos sólidos totais e sólidos totais fixos. Verifica-se que a tecnologia de tratamento de esgoto por plantas é eficiente, uma vez que as espécies taboa e caniço no sistema de fluxo subsuperficial vertical ora adotado proporcionaram resultados com remoções superiores a 60% para os atributos demanda bioquímica de oxigênio, demanda química de oxigênio, cor aparente, nitrogênio amoniacal, fosfatos, coliformes termotolerantes e turbidez.
260

Comunidade fitoplanctônica e parâmetros físico-químicos em lagoa de estabilização (Trindade,Go) / Phytoplankton and physicochemical parameters in stabilization pond (Trindade, GO)

D\'ALESSANDRO, Emmanuel Bezerra 12 July 2012 (has links)
Made available in DSpace on 2014-07-29T15:01:49Z (GMT). No. of bitstreams: 1 DALESSANDRO_Emmanuel - texto - parte 1.pdf: 1095655 bytes, checksum: 244da2ff7d05e25ed83b393557a7226d (MD5) Previous issue date: 2012-07-12 / The Wastewater Treatment Plant (WWTP) of Trindade (16 ° 39'09'' S and 49 ° 31'50'' W), also known as Barro Preto WWTP, consists of preliminary treatment followed initially by three modules in parallel (A, B and C), each containing one anaerobic pond, one facultative pond and one maturation pond in series (Australian system), being the effluent released in the stream Barro Preto. The WWTP began operating in 1997 and had the final plan in 2011. This study aimed to evaluate treatment efficiency and the module based on algal community structure and physico-chemical variables during a period of six months (September, October, November, December 2010 and April and May 2011), which contains the dry and rainy periods. Were analyzed in reference to the structure and dynamics of algae: biomass, density, richness, diversity, equality, abundance and dominance; for physic-chemical analysis were: flow rate, wastewater temperature, depth, euphotic zone, HDT, pH, DO, CND, TP, PO4 -3, NH4 +, NO3, DOB5 20°C, COD, TSS, FSS, VSS and also climatic variables. The algae were collected through non-selective process (Van Dorn bottle). The samples abiotic, chlorophyll a and pheophytin were processed according to APHA, and the density algal by the Utermöhl method. Principal Component Analysis (PCA) were performed to characterize the physic-chemical processes and the spatial and temporal differentiation. It was also made a Canonical Correspondence Analysis (CCA). The facultative and maturation ponds shown to be influenced by the seasonality of the region, and presented variance in depth. In average, the module A showed an efficiency of COD removal of 45%, and optimal efficiency in removing DBO5 20°C (84%). The facultative pond showed the highest mean of PO4 -3 efficiency removal (48%), NH4 + (36%) NO3 - (44%), BOD5 20°C (74%). OD profile of type clinograde and thermal stratification was recorded in three months of collection. The maturation pond showed higher mean removal efficiency of PT (27%) and COD (19%). In just two months was recorded thermal stratification, and found clinograde profile throughout the study. The ponds presented one of the largest ever recorded phytoplankton densities in stabilization ponds and 170 taxa recorded throughout the study, being 40% of cyanobacteria are potentially toxic. The most abundant species in both ponds and throughout the study were Chlorella vulgaris, Chlorella minutissima, Closteriopsis acicularis, Merismopedia tenuissima, Synechococcus sp and Synechocysitis sp (dominant). The ponds presented according to the indices, low species diversity and low beta diversity. The beta diversity showed that the maturation pond has more flexibility in the rainy season and optional in the dry season. The canonical correspondence analysis (CCA) showed the most abundant species when best developed in seasonality. C. acicularis in the rainy season, C. minutissima in the end of the rainy season and the beginning of the dry season, M. tenuissima in late dry season, C. vulgaris and Synechococcus sp in late dry season and beginning of precipitation. This analysis showed which environmental variables can also influence the in distribution of species. / A Estação de Tratamento de Esgotos (ETE) de Trindade (16°39 09 S e 49°31 50 O), conhecida também como ETE Barro Preto, é composta por tratamento preliminar seguido, inicialmente, por três módulos em paralelo (A, B e C), contendo cada, uma lagoa anaeróbia, uma lagoa facultativa e uma lagoa de maturação em série (sistema australiano), sendo o efluente lançado no córrego Barro Preto. O presente estudo visou avaliar e eficiência de tratamento do módulo A com base na estrutura da comunidade algal e em variáveis físico-químicas, num período de seis meses (setembro, outubro, novembro, dezembro de 2010 e abril e maio de 2011), que contém períodos de estiagem e chuvosos. Foram analisados a estrutura e a dinâmica das algas: biomassa, densidade, riqueza, diversidade, equidade, abundância e a dominância; para as análises físico-químicas foram: vazão, temperatura da água residuária, profundidade, zona eufótica, TDH, pH, OD, CND, PT, PO4 -3, NH4 +, NO3, DBO5 20°C, DQO, SST, SSF, SSV e também variáveis climáticas. As algas foram coletadas através de processo não seletivo (garrafa de van Dorn). As amostras abióticas, clorofila a e feofitina foram processadas de acordo com APHA, e a densidade algal pelo método de Utermöhl. Análises de Componentes Principais (ACP) foram feitas para caracterização dos processos físico-químicos e para a diferenciação espacial e temporal. Também foi feita uma Análise de Correspondência Canônica (ACC), com o intuito de verificar como as espécies mais abundantes se comportaram em relação as variáveis abióticas. A lagoa facultativa e de maturação mostraram influência da sazonalidade da região, além de apresentar variações na profundidade. Em média, o módulo A apresentou eficiência de remoção de DQO de 45%, e eficiência na remoção de DBO5 20°C de 84%. A lagoa facultativa foi a que apresentou maior média de eficiência de remoção de PO4 -3 (48%), NH4 + (36%), NO3 (44%), DBO5 20°C (74%). Registrou-se também perfil de OD do tipo clinogrado e estratificação térmica em três meses de coleta. A lagoa de maturação apresentou maior média de eficiência de remoção de PT (27%) e DQO (19%). Em apenas dois meses foi registrada a estratificação térmica, e verificou-se perfil clinogrado durante todo o estudo. As lagoas apresentaram uma das maiores densidades fitoplanctônicas já registrada em lagoas de estabilização, com 170 táxons durante todo o estudo, e 40% das cianobactérias registradas são potencialmente tóxicas. As espécies mais abundantes em ambas as lagoas e durante todo o estudo foram Chlorella vulgaris, Chlorella minutissima, Closteriopsis acicularis, Merismopedia tenuissima, Synechococcus sp e Synechocystis sp (dominante). As lagoas apresentaram de acordo com os índices, pouca diversidade específica e pouca diversidade beta. A diversidade beta revelou que a lagoa de maturação tem maior flexibilidade no período chuvoso e a facultativa no período de seca. As Análises de correspondência canônica (ACC) mostraram quando as espécies mais abundantes melhor se desenvolveram na sazonalidade. C. acicularis no período chuvoso, C. minutissima na final da chuva e início de seca, M. tenuissima no final da seca, C. vulgaris e Synechococcus sp. em no final da seca e início de chuva. Esta análise mostrou também que variáveis ambientais também podem influenciar na distribuição das espécies.

Page generated in 0.1137 seconds