• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 103
  • 3
  • 1
  • 1
  • Tagged with
  • 109
  • 109
  • 54
  • 53
  • 53
  • 25
  • 20
  • 20
  • 20
  • 19
  • 19
  • 15
  • 13
  • 13
  • 12
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
71

UMA METODOLOGIA PARA ALOCAÇÃO DE PERDAS ATIVAS DE TRANSMISSÃO EM AMBIENTE COMPETITIVO / A METHODOLOGY FOR LOSS ACTIVE ALLOCATION OF TRANSMISSION IN COMPETITIVE ENVIRONMENT

Santos Junior, Bartolomeu Ferreira dos 13 April 2007 (has links)
Made available in DSpace on 2016-08-17T14:53:08Z (GMT). No. of bitstreams: 1 Bartolomeu ferreira.pdf: 2681101 bytes, checksum: 05d2fad3f69568c193c20ccd8addecd7 (MD5) Previous issue date: 2007-04-13 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The goal of loss allocation methodologies is to share the responsibility for transmission losses among generators and loads. Several loss allocation methods have been developed to solve this problem. However, there is not consensus regarding to the most appropriated approach methodology. There are some methods presenting suitable accuracy, however, still remains the equity question. It can say that there isn t an ideal method, although it is desirable that any method achieve efficient allocation criteria. In this work, it is proposed a methodology for active power transmission loss allocation, based on circuit laws, proportional sharing and superposition principles. The methodology uses a load flow solution to share the global loss of the system among market participants. The problem is divided into operation scenarios and taking into account transmission paths used by generators to supply the loads. Tests, analyses and comparison with some methods proposed in literature are performed, using a five bus test system, and IEEE 30 and IEEE 118 systems. / Os métodos de alocação de perdas têm como objetivo distribuir entre os geradores e cargas a responsabilidade por perdas no sistema de transmissão, de uma forma equilibrada. Embora existam vários métodos de alocação propostos na literatura para resolver este problema, ainda não existe um consenso sobre o melhor critério a ser seguido, sendo que atualmente cada país utiliza uma metodologia diferente com maior ou menor grau de aproximação. Há alguns métodos que poderiam ser considerados como exatos , entretanto a questão da equidade ainda continua em aberto. Pode-se afirmar que ainda não existe nenhum método ideal, embora seja desejável que qualquer metodologia objetive atingir a critérios eficientes de alocação. Neste trabalho é proposta uma metodologia para alocação de perdas ativas de transmissão, baseada nas leis de circuito, no princípio da divisão proporcional e no teorema da superposição. A metodologia utiliza os resultados de um fluxo de carga para alocar eficientemente a perda total do sistema entre os participantes do mercado, dividindo o problema em cenários de operação e considerando os caminhos de transmissão utilizados pelos geradores para suprir as demandas das cargas. São realizadas simulações e análises e comparações com alguns métodos já propostos na literatura, utilizando-se: um sistema teste de cinco barras, e os sistemas IEEE 30 e IEEE 118.
72

VIABILIDADE ECONÔMICA DA GERAÇÃO DE ENERGIA ELÉTRICA A PARTIR DO BIOGÁS GERADO EM ESTAÇÃO DE TRATAMENTO DE EFLUENTE INDUSTRIAL DE CERVEJARIAS / ECONOMIC FEASIBILITY OF ELECTRICAL POWER GENERATION FROM BIOGAS GENERATED IN SEASON TREATMENT WASTEWATER INDUSTRIAL BREWERIES

Silva, Adriana Ribeiro da 03 November 2014 (has links)
Made available in DSpace on 2016-08-18T17:23:40Z (GMT). No. of bitstreams: 1 DISSERTACAO_ADRIANA RIBEIRO DA SILVA.pdf: 1163830 bytes, checksum: c403597f947d78945683fa34afa48d7d (MD5) Previous issue date: 2014-11-03 / Several industrial wastewater treatment plants using biogas from anaerobic processes in plants as a source of fuel for generators of electricity. This biogas comprises mainly methane which results from the digestion of organic matter in bioreactors. Biogas as alternative energy source, can be a viable solution for two major global problems that comes with population growth: increasing energy consumption and increased production of solid, liquid and gaseous. The viability of such use depends directly on the capacity of each project. This work is an approach to the study of economic viability of biogas use generated in a brewery for conversion into electricity. All data collected were collected during the period from June 2013 to July 2014, in the company's information system. The biogas generated in ETEI a brewery for conversion to electricity was studied. As the deployment of value biogas reuse project, the cost reduction opportunity for brewing and demonstrated the economic viability of biogas reuse as electric power through more traditional financial indicators as payback (bp), net present value (NPV), internal rate of return (IRR), efficiency ratio and hurdle rate. Because the growth of drinking and consequently organic load in effluent generation, as we have great potential in this business the generation of biogas that can be converted into electrical energy using already dominated the market technology. / Várias estações de tratamento de efluentes industriais utilizam biogás, proveniente de processos anaeróbios, em usinas como fonte de combustível para grupos geradores de energia elétrica. Este biogás é composto principalmente de metano que resulta da digestão da matéria orgânica em biorreatores. O biogás como fonte de energia alternativa, pode ser uma saída viável para dois dos maiores problemas mundial que vem acompanhando o crescimento populacional: o consumo cada vez maior de energia e, o aumento da produção de resíduos sólidos, líquidos e gasosos. A viabilidade desse tipo de utilização depende diretamente da capacidade produtiva de cada empreendimento. Este trabalho faz uma abordagem do estudo de viabilidade econômica do uso de biogás gerado em uma cervejaria para conversão em energia elétrica. Todos os dados levantados foram coletados durante o período de junho de 2013 a julho de 2014, no sistema de informações da empresa. Foi estudada a produção de biogás gerado na ETEI de uma cervejaria para conversão em energia elétrica. Assim como o valor de implantação do projeto de reaproveitamento de biogás, a oportunidade de redução de custo na produção de cerveja e demonstrado a viabilidade econômica do reaproveitamento do biogás como energia elétrica através dos indicadores financeiros mais tradicionais como payback (pb), valor presente líquido (VPL), taxa interna de retorno (TIR), índice de eficiência e taxa de atratividade. Devido o crescimento do consumo de bebidas e consequentemente geração de carga orgânica nos efluentes, temos como grande potencial nesse ramo a geração de biogás que pode ser convertida em energia elétrica utilizando tecnologia já dominada no mercado.
73

Estudo analítico experimental de um conjunto gaseificador

MORAES, Sinfrônio Brito January 1983 (has links)
Submitted by Edisangela Bastos (edisangela@ufpa.br) on 2018-03-28T13:08:25Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_EstudoAnaliticoExperimental.pdf: 2764706 bytes, checksum: 23a8474d6c0a8add2635345dfc0f84d0 (MD5) / Approved for entry into archive by Edisangela Bastos (edisangela@ufpa.br) on 2018-04-02T14:17:35Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_EstudoAnaliticoExperimental.pdf: 2764706 bytes, checksum: 23a8474d6c0a8add2635345dfc0f84d0 (MD5) / Made available in DSpace on 2018-04-02T14:17:35Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_EstudoAnaliticoExperimental.pdf: 2764706 bytes, checksum: 23a8474d6c0a8add2635345dfc0f84d0 (MD5) Previous issue date: 1983 / O estudo proposto neste trabalho está baseado num estudo de parâmetros influentes no processo de gaseificação ascendente ou Contra-Corrente. O gaseificador utilizado foi um prototipo modular. O módulo inferior com diâmetro externo de 50cm e diâmetro interno 42cm devido ao refratário e às paredes duplas para o pré-aquecimento do ar de entrada. O módulo superior de diâmetro externo de 55 cm e interno 50,6 cm é constituido também de paredes duplas por causa das extrações de gás estarem lozalizadas a duas alturas diferentes. Os dois módulos são acplados entre si de tal maneira que podemos variar a altura de carga do gaseificador, assim como, a altura da saída de gás. O processo utilizado na gaseificação foi o "gás de ar" ou "gás pobre". O estudo foi dividido em duas geometrias, variando entre elas a relação da altura da saída de gás pelo diâmetro do gaseificado. Quando a extração de gás se processou pelos furos superiores com uma relação δ = 3,09 denomina-mos de geometria superior e para δ = 2,14 de geometria inferior. Para cada uma das geometrias foram realizadas cinco experiências com vazões de ar diferentes. Foram medidas as temperaturas em três pontos distintos do gaseificados a fim de verificarmos o comportamento das zonas de reação de acordo com as temperaturas, assim como, os fluxos de ar, gás, carvão gaseificado e vapor d'água contido no ar foram medidos a fim de que as análises fossem feitas es termos de parâmetros adimensionais. A composição do gás foi analisada cromatograficamente para todos os experimentos a fim de determinarmos o poder calorífico do gás, as parcelas de energia de cada componente na mistura do gás resultante, a potência calorífica do gaseificador. Com relação a composição do gás de ar, devido as nossas condições ambientais a gaseificação comportou-se como se fosse uma composição de gás d'água apresentando em sua análise parcelas de hidrogênio e metano proporcionando assim um aumento no poder calorífico do gás e consequentemente aumento da potência calorífica do gaseificador. / The research subject proposed in this study is based on an examination of the parameters significant for the process of ascendent and counter-current gasification. The gasifier which was utilized was a module proto type. The lower module has an extenal diameter of 50 cm and an internail diameter of 42 cm, owing to the refractory and to the double walls designed for the heating of the incoming air. The upper module with an external diameter of 55 cm and an internal diameter of 50,6 cm, is similarly made of double walls in view of the extraction of gas being localized at different The two modules are joined to each other in such a way as to enable a variation in the height of the charging of the gasifier, as well as in the height of the outgoing gas. The process of gasification used in the study was that of air gas or low-BTU gas. The study was divided into two geometries by varying be tween them, the relation of the height of the outgoing gas and the diameter of the gasifier. When gas was extracted by the upper perforation with a relation δ = 3,09 it is denominated upper geometry andwhen δ=214, lower geometry. Five experimento involving different escapes of air were made for each of the geometries. Temperatus were measured at three different points of the gasifier in order to ascertain the behavior of the reaction zones according to the temperatures. The flows of air, gas, gasified coal and steam contained in the air were measured so that the analyses were made in terms of dimensional parameters. The composition of the gas was analyses chromografically in all the experiments undertaken, so as to determine the calorific potential of the gas, the percent of energy in each component of the resultant mixed gas, and the calorific power of the gasifier. In relation to the composition of air gas, the gasification behaved as if it were a mixture of water gas, owing to local ambiental condition. The composition presented, on analysis, parts of hydrogen and methane, thus contributing to an increase in the heating power of the gas and consequently, an increase in the heating potential of the gasifier.
74

Análise da resistência a corrosão do aço carbono revestido com Al55-Zn após deformação mecânica e tratamento térmico

BESERRA, Antonio Adelmo Freire 12 January 2001 (has links)
Submitted by Edisangela Bastos (edisangela@ufpa.br) on 2018-03-28T17:05:06Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Tese_AnaliseResistenciaCorrosao.pdf: 6473132 bytes, checksum: 4a83f2ee43a0dcb1257ada308b39c480 (MD5) / Approved for entry into archive by Edisangela Bastos (edisangela@ufpa.br) on 2018-04-02T15:15:36Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Tese_AnaliseResistenciaCorrosao.pdf: 6473132 bytes, checksum: 4a83f2ee43a0dcb1257ada308b39c480 (MD5) / Made available in DSpace on 2018-04-02T15:15:36Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Tese_AnaliseResistenciaCorrosao.pdf: 6473132 bytes, checksum: 4a83f2ee43a0dcb1257ada308b39c480 (MD5) Previous issue date: 2001-01-12 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O revestimento de Al55-Zn apresenta uma resistência à corrosão atmosférica em média doze vezes superior à do revestimento galvanizado. Entretanto, após deformação mecânica, o revestimento de Al55-Zn apresenta microtrincas que comprometem a sua resistência à corrosão. Neste trabalho estudou-se a variação na resistência à corrosão do revestimento de Al55-Zn após deformação sob tração ou dobramento e a influência de tratamentos térmicos a '200 GRAUS' e a '360 GRAUS' durante 16h na resistência à corrosão do revestimento antes e depois das deformações. Para isso, um grupo de amostras do material foi deformado sob tensão de tração até 10% ou 15% de seu comprimento inicial e outro grupo foi dobrado até '90 GRAUS' ou '180 GRAUS'. A variação na resistência à corrosão do revestimento foi analisada através das técnicas de extrapolação de Tafel e de espectroscopia de impedância eletroquímica. Como resultado, observou-se que tanto a deformação axial quanto o dobramento do material reduzem a sua resistência à corrosão. Após o tratamento térmico a '360 GRAUS' as amostras deformadas até 10% ou 15% recuperaram a sua resistência à corrosão, entretanto, as amostras dobradas até '90 GRAUS' ou '180 GRAUS' apresentaram apenas uma recuperação parcial na sua resistência à corrosão após os tratamentos térmicos. / Analysis of the corrosion resistance of the 55AI-Zn coating on carbon steel after mechanical deformation and heat treatment The atmospheric corrosion resistance of 55%Al-Zn alloy coating on average is twelve times that of an equal thickness of galvanized coating. However, it has been shown that microcracks were observed at all levels of strain under simple uniaxial tension. Our research has been focused on determining the degree of corrosion experienced by these coatings after deformation under simple tension or bending and how much the heat treatment at '200 DEGREES' or '360 DEGREES' for 16h can influence the corrosion resistance of the coating. The coated sheet samples were strained to 10% or 15% engineering strain while another group of samples was bent to bend angles of '90 DEGREES' or '180 DEGREES'. The corrosion resistance of the samples was evaluated trhough Tafel extrapolation and electrochemical impedance spectroscopy methods. As a result, it was observed that both the straining and the bending of the coating reduces its corrosion resistance. After the heat treatment at '360 DEGREES' the samples strained to 10% or 15% recover their corrosion resistance, but the specimens bended to '90 DEGREES' or '180 DEGREES' recuperate only partially the corrosion resistance after the heat treatments.
75

Simulação de sistemas de simples estágios de refrigeração por compressão de vapor / Simulation refrigeration systems of single stage vapor compression

ZIGMANTAS, Paulo Vitor de Matos 18 September 2006 (has links)
Submitted by Irvana Coutinho (irvana@ufpa.br) on 2012-05-29T12:40:21Z No. of bitstreams: 2 Dissertacao_ZigmantasSimulacaoSistemasSimples.pdf: 2976848 bytes, checksum: c79813a200468f113de57854cc48e701 (MD5) license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) / Approved for entry into archive by Irvana Coutinho(irvana@ufpa.br) on 2012-05-29T12:52:02Z (GMT) No. of bitstreams: 2 Dissertacao_ZigmantasSimulacaoSistemasSimples.pdf: 2976848 bytes, checksum: c79813a200468f113de57854cc48e701 (MD5) license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) / Made available in DSpace on 2012-05-29T12:52:02Z (GMT). No. of bitstreams: 2 Dissertacao_ZigmantasSimulacaoSistemasSimples.pdf: 2976848 bytes, checksum: c79813a200468f113de57854cc48e701 (MD5) license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Previous issue date: 2006 / Na atualidade, o estudo do desempenho térmico de um sistema de refrigeração por compressão de vapor representa uma ferramenta importante no auxílio do desenvolvimento de novos produtos ou melhoria dos já existentes. Um modelo de simulação em regime permanente foi elaborado para avaliar o desempenho do sistema frigorífico. O sistema estudado inclui uma Central de Ar Condicionado, modelo PA HILTON, constituída de um compressor alternativo do tipo semi-hermético, evaporador e condensador compacto de tubos e aletas e uma válvula de expansão termostática. O modelo do condensador considera três regiões distintas de troca de calor as quais são respectivamente a região de dessuperaquecimento, condensação e subresfriamento. Para a modelagem do evaporador, foram consideradas as regiões de evaporação e superaquecimento. No modelo de simulação foram utilizadas correlações adequadas para a estimativa dos coeficientes de transferência de calor e perda de pressão para cada região do evaporador e condensador. Não foram consideradas a transferência de calor e queda de pressão nas linhas de conexão entre os componentes. A solução do sistema de equações não lineares resultantes da modelagem matemática dos componentes do sistema simulado foi obtida utilizando-se o método das substituições sucessivas com o emprego do software Engineenng Equation Solver . Os resultados obtidos pelo modelo de simulação apresentaram erros inferiores a 9% em relação aos valores experimentais. / Nowadays, the thermal performance of refrigeration systems of vapor compression is a very important toll to aid on the development of News Products or Upgrading them. A steady state simulation model is presented to estimate the refrigeration systems performance.The studied system considers a air conditioning equipment Model PA HILTON, that includes a semi-hermetic alternative compressor, a compact tube and fins evaporator and condenser and finally a thermostatic expansion valve. The condenser mathematical model takes account of three different regions of heat transfer : cooling, condensing and sub-cooling.The evaporator mathematical modeling considers the evaporating and superheated regions. Depending of the region studied, in the model simulated includes appropriate correlations of heat transfer and pressure droops. The heat transfer and pressure drop inside the lines between the components are not considered. The solution of non linear equation systems is obtained trough a interactive method using the Engineering Equation Solver Software. The comparations between experimental and simulated values shows a very good agreement.
76

ANÁLISE DOS IMPACTOS SÓCIO-ECONÔMICOS E AMBIENTAIS DAS INDÚSTRIAS DE CALÇADOS DA CIDADE DE CAMPINA GRANDE - PB

França, Pollyanna Xavier Nunes 20 February 2006 (has links)
Made available in DSpace on 2015-09-25T12:23:30Z (GMT). No. of bitstreams: 1 POLLYANNA_XAVIER_NUNES_FRANCA_PDF.pdf: 493506 bytes, checksum: 623aec9335caa215b61a703092dbc7ac (MD5) Previous issue date: 2006-02-20 / Since the appearance of the capitalist system until today, the industry has evolved acceleratingly as much in relation to industrial process as in types and quantity of product. Consequently, this has brought negative effects to the environment, because of high consumption of raw material, causing shortage some times, as well as causing the improper destination of the waste created during the production. This research had as objective to analyse the socio-economical and environmental impact of shoe industry of Campina Grande - PB. The study of the socio-economical aspects aimed to investigate the number of companies, functional insertion condition, that is, formal and informal conditions of the industries, number of jobs, income, among others. The study of environmental aspects investigated the methods of treatment, the final disposal of the solid waste of different kinds and quantities. The analysis of these parameters was done with data collection through questionnaire, in each company belonging to sampled universe, for future tabulation. After careful analysis of the data it can be concluded that in this branch of the industrial activity, there exists little concern with protection of the environment, seeing that a major part of the solid waste produced by the industrial activity is destined to the open dumping sites. This situation demonstrates the necessity for working with environmental management tools which may reduce the environmental impacts by this industrial sector. In relation to socio-economical question, it can be noticed that this kind of industrial activity, specifically the case studied, still absorbs a large number of labor, in spite of the significant presence of informal activity and low payment offered. / Desde o surgimento do sistema capitalista até os dias atuais, a indústria vem evoluindo aceleradamente, tanto no que diz respeito ao processo industrial quanto aos tipos e quantidades de produtos. Isso, consequentemente, tem trazido efeitos negativos ao meio ambiente devido ao alto consumo da matéria-prima, levando à escassez em alguns casos, como também ao destino indevido dos resíduos gerados durante a produção. Essa pesquisa teve como objetivo analisar os impactos sócioeconômicos e ambientais das indústrias de calçados instaladas no parque industrial da cidade de Campina Grande, estado da Paraíba . O estudo dos aspectos sócioeconômicos da pesquisa objetivou investigar a quantidade de empresas, condição de inserção funcional, isto é, formalidade e informalidade das indústrias, quantidade de emprego, renda, entre outros. O estudo dos aspectos ambientais objetivou analisar os métodos de tratamento, a disposição final dos resíduos sólidos de diferentes espécies e a quantidade dos resíduos gerados. Portanto, foi realizada a aplicação de questionários nas empresas inseridas no universo amostral, observação in loco do funcionamento rotineiro das empresas, além da análise de dados cadastrais. Após uma criteriosa análise dos dados levantados, pode-se concluir que, neste ramo de atividade industrial, não existem medidas efetivas de ações norteadoras para a preservação ambiental, haja vista ter sido constatado que grande parte dos resíduos sólidos gerados pelas atividades industriais ainda é destinada para lixões a céu aberto. Esta situação demonstra a necessidade de se trabalhar ferramentas de gestão ambiental que possibilitem a redução dos impactos ambientais que este setor industrial vem causando ao meio ambiente. No tocante às questões sócio-econômicas, pode-se perceber que este ramo de atividade industrial, no caso específico estudado, ainda absorve um contingente razoável de mão de obra, apesar da presença significativa da informalidade e da baixa remuneração ofertada.
77

ANÁLISE DA VIABILIDADE DE FILTRO ANAERÓBIO DE CHICANAS NO PÓS-TRATAMENTO DE ESGOTOS SANITÁRIOS

Silva, Vanessa Farias da 22 December 2005 (has links)
Made available in DSpace on 2015-09-25T12:23:30Z (GMT). No. of bitstreams: 1 VANESSA F SILVA.pdf: 1400231 bytes, checksum: fb9f24d41beb924c130d174f918f19f8 (MD5) Previous issue date: 2005-12-22 / The objective of this thesis is to evaluate the performance of anaerobic filter with baffles (FAC) for the post treatment of anaerobic effluent and using rings cut from PET bottles as filling medium. The experiment was carried out in three phases characterized by the hydraulic retention times of 7, 9 and 10 days, respectively. The analysis of the UASB and FAC effluents was carried out weekly to evaluate the removal efficiency of organic material expressed as BOD5 e COD, solids and its different fractions, nutrients (nitrogen and phosphorus) and indicators of faecal contamination (thermotolerant Coliforms). The results showed that there were no significant differences between the FAC effluent during the three phases with respect to organic material and suspended solids (at 5% significance level), but there were differences in the electric conductivity, nitrogen and thermotolerant Coliforms. The FAC presented good performance of organic material removal (65% for COD and 64% for BOD5 during the first phase) and suspended solids (81% for TSS and 83% for VSS during the first phase). Thus it can be noted that the FAC presented good post treatment efficiency of anaerobic effluents, resulting in clarified effluent with low concentrations of organic material (12mg BOD5.L-1), suspended solids (<10 mg TSS. L-1) and turbidity (<10 UNT). With respect to sanitary quality the produced effluent had concentrations of thermotolerant in the range of 103 to 104 UFC.100 mL-1, hence above the standards established by the WHO (1989) for utilization in irrigation without restrictions. / O presente trabalho teve como objetivo avaliar o desempenho de filtro anaeróbio de chicanas (FAC) no pós-tratamento de efluente anaeróbio, usando garrafas PET como material de enchimento. O experimento foi realizado em três fases, delimitado pelos três tempos de detenção hidráulicas, 7, 9 e 10 dias, respectivamente. As análises dos efluentes do reator UASB e do FAC foram realizadas semanalmente, averiguando a remoção de matéria orgânica na forma de DBO5 e DQO, sólidos e suas frações, nutrientes (nitrogênio e fósforo) e indicadores de contaminação fecal (coliformes termotolerantes). Os resultados mostraram que não ocorreram diferenças significativas no efluente do FAC entre as três fases, em relação a matéria orgânica e sólidos (ao nível de 5%), mas houve diferença quanto a condutividade elétrica, nitrogênio e coliformes termotolerantes. O FAC apresentou bom desempenho quanto à remoção de matéria orgânica (65% para DQO e 64% para DBO5 durante a 1ª fase) e sólidos suspensos (81% para SST e 83% para SSV durante a 1ª fase). Diante desses resultados, observa-se que o FAC apresentou boa eficiência no pós-tratamento de efluente anaeróbio resultando em um efluente clarificado com baixas concentrações de matéria orgânica (12mg DBO5.L-1), sólidos suspensos (<10 mg SST. L-1) e turbidez (<10 UNT). Com relação à qualidade sanitária, o efluente produzido apresentava concentrações de coliformes termotolerantes variando de 103 a 104 UFC.100 mL-1, portanto valores acima dos padrões estabelecidos pelo OMS (1989) para ser utilizado em irrigação irrestrita.
78

TRATAMENTO BIOLÓGICO DE EFLUENTES DE LAVA-JATO

Costa, Maria José Comandante 21 February 2006 (has links)
Made available in DSpace on 2015-09-25T12:23:32Z (GMT). No. of bitstreams: 1 MARIA_JOSE_COMANDANTE_COSTA.pdf: 1369694 bytes, checksum: 2b63fa3023c60448918ab6ae6b29a54f (MD5) Previous issue date: 2006-02-21 / The research was realized in four phases. In the 1st phase, interviews were accomplished with proprietors of car-washes with the objective of knowing your environmental and social impacts. In the 2nd phase synthetic effluents of car-washes were treated during 147 days in batch anaerobic reactors with five different oil and detergent concentrations. In the 3rd phase six reactors were monitored in batch form, during 20 days, with substrate containing high oil concentrations (0,5 to 2,5 g.l-1) and surfactants concentrations (5,0g.L-1). These treatments were realized with purpose to verified the relation between oil concentration and inhibition of the biologic activity. In the 4th phase six batch anaerobic reactors, with different proportions of the surfactant, were monitored during 35 days. The concentrations of organic matter influent and effluent were analyzed in all the treatments and in the sludge were determined solid concentration. Daily the biogas produced was measures and characterized. In the 2nd phase the average removal of soluble COD was about 82%, for a monitoring period of 18 days. For raw COD during 100 days of operation the average removal was approximately 76% and the production of methane was directly proportional the substrate concentrations. It was verified that the anaerobic biological activity occurs in surfactant concentration below 0,5 g.L-1, and starting from that concentration it begins to happen inhibition of the process. / O presente trabalho foi desenvolvido em quatro fases. A primeira fase teve o objetivo de levantar dados sobre os impactos ambientais e sociais causados pelos lava-jatos. Para tanto, foram realizadas entrevistas com seus proprietários. Na segunda fase, foram tratados anaerobiamente, durante 147 dias, em reatores de batelada, efluentes sintéticos de lava-jatos com cinco diferentes concentrações de óleo e detergente. Na terceira fase, foram monitorados seis reatores anaeróbios, em regime de batelada, durante 20 dias, com substratos contendo altas concentrações de óleo (0,5 a 2,5 g.L-1) e surfactantes (5,0 g.L-1). Estes tratamentos tiveram por finalidade verificar se, com o aumento da concentração de óleo, haveria inibição da atividade biológica. Na quarta fase, foram realizados, anaerobiamente, em reatores de batelada, durante 35 dias, seis experimentos com diferentes concentrações de surfactante para verificar que concentração inibiria o processo biológico anaeróbio. Para todos os tratamentos foram analisadas as concentrações de matéria orgânica (DQO) afluente e efluente, bem como as concentrações de sólidos do lodo. Diariamente, foram realizadas leituras do volume e da composição do biogás. Como resultados da segunda fase, verificaram-se remoções de DQO solúvel média de 82% aos 18 dias e para DQO bruta em torno de 76% para os cinco tratamentos, durante 100 dias de operação. A produção de metano foi diretamente proporcional às concentrações dos substratos. Constatou-se que a atividade biológica anaeróbia ocorre numa concentração de surfactante de até aproximadamente 0,5 g.L-1, sendo que a partir daí, começa a ocorrer inibição do processo.
79

FOTOCATÁLISE HETEROGÊNEA NO POLIMENTO DE EFLUENTES SINTÉTICOS DE CURTUME: alternativa para minimizar impactos ambientais

Pascoal, Salomão de Andrade 23 February 2006 (has links)
Made available in DSpace on 2015-09-25T12:23:36Z (GMT). No. of bitstreams: 1 SALOMAO_DE_ANDRADE_PASCOAL.pdf: 1571379 bytes, checksum: 8dcb3d302822615da27bf933016a3cef (MD5) Previous issue date: 2006-02-23 / The industry is a section of the contemporary society with great pollutant potential of the environment, especially of the aquatic ecosystems. The tanning industries are big producing of dejections with significant amounts of organic matter and of chrome. The conventional processes of treatment applied those dejections, not always they possess good effectiveness. Actuality, the Advanced Oxidation Processes represent an excellent alternative of tertiary treatment. In the present study, the application of the heterogeneous photocatalysis was evaluated, being used a photocatalyst (TiO2) immobilized, in the tertiary treatment of synthetic liquid effluents representative of tanning industries. It was aimed at to remove Cr(VI) and organic matter. The photocatalytic reactor was of the type Fixed Bed of Fine Film, built with a plate of glass arrayed for the fixation of TiO2. It was adopted as radiation sources, the sun and lamps issuing of UV radiation (l= 250 nm). The smallest values of removal effectiveness for Cr(VI) they were of 62% and 51% and of DOC they were from 60% and 53% to the experiments done with radiation UV originating from of the sun and of lamps, respectively. The results of the parameters related to the reduction phases and oxidation of the heterogeneous photocatalysis, they showed that the exhibition in the sun, he/she has effectiveness of larger relative removal than the exhibition to UV lamps. The data of relative removal of Cr(VI) and of DOC and the constants kinetics of these parameters, they indicated that the adopted experimental configurations optimized the phase of reduction of the heterogeneous photocatalysis. / A indústria é um setor da sociedade contemporânea com grande potencial poluidor do meio ambiente, especialmente dos ecossistemas aquáticos. As indústrias de curtume são grandes produtoras de dejetos com significativas quantidades de material orgânico e de cromo. Os processos convencionais de tratamento aplicados a esses dejetos, nem sempre possuem boa eficácia. Atualmente, os Processos Oxidativos Avançados representam uma excelente alternativa de tratamento terciário. No presente estudo, avaliou-se a aplicação da fotocatálise heterogênea, usando-se um fotocatalisador (TiO2) imobilizado, no tratamento final de efluentes líquidos sintéticos representativos de indústrias de curtume. Objetivou-se remover Cr(VI) e matéria orgânica. O fotorreator foi do tipo Leito Fixo de Filme Fino, construído com uma placa de vidro jateado para a fixação do TiO2. Adotou-se como fontes de radiação, o sol e lâmpadas germicidas emissoras de radiação UV (l= 250 nm). Os menores valores de eficácia de remoção para Cr(VI) foram de 62% e 51% e de DQO foram de 60% e 53% para os experimentos feitos com radiação UV oriundas do sol e de lâmpadas, respectivamente. Os resultados dos parâmetros relacionados às fases de redução e oxidação da fotocatálise heterogênea, mostraram que a exposição ao sol, tem eficácia de remoção relativa maior do que a exposição à lâmpadas UV. Os dados de remoção relativa de Cr(VI) e de DQO e as constantes cinéticas destes parâmetros, indicaram que as configurações experimentais adotadas otimizaram a fase de redução da fotocatálise heterogênea.
80

Análise computacional dos campos de velocidade e temperatura do ambiente interno da usina termelétrica Santana - Amapá

OLIVEIRA FILHO, Álvaro Henriques de 07 August 2008 (has links)
Submitted by Cleide Dantas (cleidedantas@ufpa.br) on 2014-04-07T13:52:52Z No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Dissertacao_AnaliseComputacionalCampos.pdf: 8199135 bytes, checksum: 4e41ee450e20c1b754db24b43b82d5fa (MD5) / Approved for entry into archive by Ana Rosa Silva (arosa@ufpa.br) on 2014-06-16T13:18:05Z (GMT) No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Dissertacao_AnaliseComputacionalCampos.pdf: 8199135 bytes, checksum: 4e41ee450e20c1b754db24b43b82d5fa (MD5) / Made available in DSpace on 2014-06-16T13:18:05Z (GMT). No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Dissertacao_AnaliseComputacionalCampos.pdf: 8199135 bytes, checksum: 4e41ee450e20c1b754db24b43b82d5fa (MD5) Previous issue date: 2008 / A simulação numérica do escoamento de ar em ambientes internos é na atualidade o método mais apropriado para análise de conforto térmico em ambientes internos. O escoamento de ar nesses ambientes configura-se como um escoamento complexo, pois, em regra geral, é uma combinação de escoamentos cisalhantes livres (jatos) e cisalhantes de parede, além disso, esses escoamentos são governados por forças de inércia e forças de empuxo, caracterizando-o como de convecção mista. A combinação desses mecanismos cria um escoamento com características complexas, como zonas de recirculação, vórtices, descolamento e recolamento de camada-limite dentre outras. Portanto, a precisão da solução estará diretamente ligada, principalmente, na habilidade do modelo de turbulência adotado de reproduzir as características turbulentas do escoamento de ar e da transferência térmica. O objetivo principal do presente trabalho foi a simulação computacional do ambiente térmico interno do galpão que abriga os geradores e motores Wärtzilä da Usina Termelétrica Santana no estado do Amapá. A formulação matemática baseada na solução das equações gerais de conservação inclui uma análise dos principais modelos de turbulência aplicados ao escoamento de ar em ambientes internos, assim como os processos de transferência de calor associados. Na modelagem numérica o método de volumes finitos é usado na discretização das equações de conservação, através do código comercial Fluent-Airpak, que foi usado nas simulações computacionais para a análise dos campos de velocidade e temperatura do ar. A utilização correta do programa computacional foi testada e validada para o problema através da simulação precisa de casos retirados da literatura. Os resultados numéricos foram comparados a dados obtidos de medições experimentais realizados no galpão e apresentou boa concordância, considerando a complexidade do problema simulado, o objetivo da simulação em face da diminuição da temperatura no interior do galpão e, também, em função das limitações encontradas quando da tomada das medições experimentais. Além disso, foram feitas simulações de estratégias de melhoria do ambiente térmico da Usina, baseadas na realidade levantada e nos resultados da simulação numérica. Finalmente, foram realizadas simulações do protótipo de solução proposto para a diminuição da temperatura interna do galpão o que possibilitará um aumento, na faixa de 20 a 30%, do tempo de permanência no interior do galpão. / The numerical simulation of the airflow in internal environments is in the present time the most appropriate method for analysis of thermal comfort indoors. The airflow in these environments is configured as a complex one, therefore, in general, it is a combination of free-shear flow (jet) and of wall-shear flow, moreover, these are governed by inertia and buoyancy forces, characterizing a situation of mixing convection. The combination of these mechanisms creates an airflow with complex characteristics, as recirculation zones, vortices, detachment and re-attachment of boundary layer amongst others. Therefore, the precision of the solution will be directly connected, mainly, with the ability of the adopted turbulence model to reproduce the turbulent characteristics of the airflow and thermal transfers. The main objective of the present work was the computational simulation of the internal thermal environment of the enclosure which shelters the generators and the Wärtzilä engines of the thermo-electric power plant of Santana in the state of Amapá (Brazil). The mathematical formulation based on the solution of the general equations of conservation includes an analysis of the principal models of turbulence applied to the airflow inside the enclosure, as well as the heat transfer processes associated. The finite-volume numerical method is used in the discretization of the conservation equations, through the Fluent-Airpak software, for the analysis of the distribution of air velocity and temperature fields. The correct use of the software was tested and validated by successfully simulating problems solved by other authors. The numerical results of the airflow in the enclosure were compared with the experimental data and presented a good agreement, by considering the complexity of the simulated problem and the limitations and difficulties found during measurements. Moreover, simulations are presented of strategies for improvement of the thermal environment, based on the actual reality and on the results of the numerical simulations. Finally, simulations of a prototype solution are presented with the reduction of the internal temperature in the enclosure. This solution allows an increase of the exposure time inside the enclosure, from 20 up to 30%, and improves the thermal comfort of the thermo-electric power plant.

Page generated in 0.1102 seconds