Spelling suggestions: "subject:"engenharia termicamente"" "subject:"engenharia termodinâmica""
71 |
UMA METODOLOGIA PARA ALOCAÇÃO DE PERDAS ATIVAS DE TRANSMISSÃO EM AMBIENTE COMPETITIVO / A METHODOLOGY FOR LOSS ACTIVE ALLOCATION OF TRANSMISSION IN COMPETITIVE ENVIRONMENTSantos Junior, Bartolomeu Ferreira dos 13 April 2007 (has links)
Made available in DSpace on 2016-08-17T14:53:08Z (GMT). No. of bitstreams: 1
Bartolomeu ferreira.pdf: 2681101 bytes, checksum: 05d2fad3f69568c193c20ccd8addecd7 (MD5)
Previous issue date: 2007-04-13 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The goal of loss allocation methodologies is to share the responsibility for transmission losses among generators and loads. Several loss allocation methods have been developed to solve this problem. However, there is not consensus regarding to the most appropriated approach methodology.
There are some methods presenting suitable accuracy, however, still remains the equity question. It can say that there isn t an ideal method, although it is desirable that any method achieve efficient allocation criteria.
In this work, it is proposed a methodology for active power transmission loss allocation, based on circuit laws, proportional sharing and superposition principles.
The methodology uses a load flow solution to share the global loss of the system among market participants. The problem is divided into operation scenarios and taking into account transmission paths used by generators to supply the loads.
Tests, analyses and comparison with some methods proposed in literature are performed, using a five bus test system, and IEEE 30 and IEEE 118 systems. / Os métodos de alocação de perdas têm como objetivo distribuir entre os geradores e cargas a responsabilidade por perdas no sistema de transmissão, de uma forma equilibrada. Embora existam vários métodos de alocação propostos na literatura para resolver este problema, ainda não existe um consenso sobre o melhor critério a ser seguido, sendo que atualmente cada país utiliza uma metodologia diferente com maior ou menor grau de aproximação.
Há alguns métodos que poderiam ser considerados como exatos , entretanto a questão da equidade ainda continua em aberto. Pode-se afirmar que ainda não existe nenhum método ideal, embora seja desejável que qualquer metodologia objetive atingir a critérios eficientes de alocação.
Neste trabalho é proposta uma metodologia para alocação de perdas ativas de transmissão, baseada nas leis de circuito, no princípio da divisão proporcional e no teorema da superposição.
A metodologia utiliza os resultados de um fluxo de carga para alocar eficientemente a perda total do sistema entre os participantes do mercado, dividindo o problema em cenários de operação e considerando os caminhos de transmissão utilizados pelos geradores para suprir as demandas das cargas.
São realizadas simulações e análises e comparações com alguns métodos já propostos na literatura, utilizando-se: um sistema teste de cinco barras, e os sistemas IEEE 30 e IEEE 118.
|
72 |
VIABILIDADE ECONÔMICA DA GERAÇÃO DE ENERGIA ELÉTRICA A PARTIR DO BIOGÁS GERADO EM ESTAÇÃO DE TRATAMENTO DE EFLUENTE INDUSTRIAL DE CERVEJARIAS / ECONOMIC FEASIBILITY OF ELECTRICAL POWER GENERATION FROM BIOGAS GENERATED IN SEASON TREATMENT WASTEWATER INDUSTRIAL BREWERIESSilva, Adriana Ribeiro da 03 November 2014 (has links)
Made available in DSpace on 2016-08-18T17:23:40Z (GMT). No. of bitstreams: 1
DISSERTACAO_ADRIANA RIBEIRO DA SILVA.pdf: 1163830 bytes, checksum: c403597f947d78945683fa34afa48d7d (MD5)
Previous issue date: 2014-11-03 / Several industrial wastewater treatment plants using biogas from anaerobic processes in plants as a source of fuel for generators of electricity. This biogas comprises mainly methane which results from the digestion of organic matter in bioreactors. Biogas as alternative energy source, can be a viable solution for two major global problems that comes with population growth: increasing energy consumption and increased production of solid, liquid and gaseous. The viability of such use depends directly on the capacity of each project. This work is an approach to the study of economic viability of biogas use generated in a brewery for conversion into electricity. All data collected were collected during the period from June 2013 to July 2014, in the company's information system. The biogas generated in ETEI a brewery for conversion to electricity was studied. As the deployment of value biogas reuse project, the cost reduction opportunity for brewing and demonstrated the economic viability of biogas reuse as electric power through more traditional financial indicators as payback (bp), net present value (NPV), internal rate of return (IRR), efficiency ratio and hurdle rate. Because the growth of drinking and consequently organic load in effluent generation, as we have great potential in this business the generation of biogas that can be converted into electrical energy using already dominated the market technology. / Várias estações de tratamento de efluentes industriais utilizam biogás, proveniente de processos anaeróbios, em usinas como fonte de combustível para grupos geradores de energia elétrica. Este biogás é composto principalmente de metano que resulta da digestão da matéria orgânica em biorreatores. O biogás como fonte de energia alternativa, pode ser uma saída viável para dois dos maiores problemas mundial que vem acompanhando o crescimento populacional: o consumo cada vez maior de energia e, o aumento da produção de resíduos sólidos, líquidos e gasosos. A viabilidade desse tipo de utilização depende diretamente da capacidade produtiva de cada empreendimento. Este trabalho faz uma abordagem do estudo de viabilidade econômica do uso de biogás gerado em uma cervejaria para conversão em energia elétrica. Todos os dados levantados foram coletados durante o período de junho de 2013 a julho de 2014, no sistema de informações da empresa. Foi estudada a produção de biogás gerado na ETEI de uma cervejaria para conversão em energia elétrica. Assim como o valor de implantação do projeto de reaproveitamento de biogás, a oportunidade de redução de custo na produção de cerveja e demonstrado a viabilidade econômica do reaproveitamento do biogás como energia elétrica através dos indicadores financeiros mais tradicionais como payback (pb), valor presente líquido (VPL), taxa interna de retorno (TIR), índice de eficiência e taxa de atratividade. Devido o crescimento do consumo de bebidas e consequentemente geração de carga orgânica nos efluentes, temos como grande potencial nesse ramo a geração de biogás que pode ser convertida em energia elétrica utilizando tecnologia já dominada no mercado.
|
73 |
Estudo analítico experimental de um conjunto gaseificadorMORAES, Sinfrônio Brito January 1983 (has links)
Submitted by Edisangela Bastos (edisangela@ufpa.br) on 2018-03-28T13:08:25Z
No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Dissertacao_EstudoAnaliticoExperimental.pdf: 2764706 bytes, checksum: 23a8474d6c0a8add2635345dfc0f84d0 (MD5) / Approved for entry into archive by Edisangela Bastos (edisangela@ufpa.br) on 2018-04-02T14:17:35Z (GMT) No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Dissertacao_EstudoAnaliticoExperimental.pdf: 2764706 bytes, checksum: 23a8474d6c0a8add2635345dfc0f84d0 (MD5) / Made available in DSpace on 2018-04-02T14:17:35Z (GMT). No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Dissertacao_EstudoAnaliticoExperimental.pdf: 2764706 bytes, checksum: 23a8474d6c0a8add2635345dfc0f84d0 (MD5)
Previous issue date: 1983 / O estudo proposto neste trabalho está baseado num estudo de parâmetros influentes no processo de gaseificação ascendente ou Contra-Corrente. O gaseificador utilizado foi um prototipo modular. O módulo inferior com diâmetro externo de 50cm e diâmetro interno 42cm devido ao refratário e às paredes duplas para o pré-aquecimento do ar de entrada. O módulo superior de diâmetro externo de 55 cm e interno 50,6 cm é constituido também de paredes duplas por causa das extrações de gás estarem lozalizadas a duas alturas diferentes. Os dois módulos são acplados entre si de tal maneira que podemos variar a altura de carga do gaseificador, assim como, a altura da saída de gás. O processo utilizado na gaseificação foi o "gás de ar" ou "gás pobre". O estudo foi dividido em duas geometrias, variando entre elas a relação da altura da saída de gás pelo diâmetro do gaseificado. Quando a extração de gás se processou pelos furos superiores com uma relação δ = 3,09 denomina-mos de geometria superior e para δ = 2,14 de geometria inferior. Para cada uma das geometrias foram realizadas cinco experiências com vazões de ar diferentes. Foram medidas as temperaturas em três pontos distintos do gaseificados a fim de verificarmos o comportamento das zonas de reação de acordo com as temperaturas, assim como, os fluxos de ar, gás, carvão gaseificado e vapor d'água contido no ar foram medidos a fim de que as análises fossem feitas es termos de parâmetros adimensionais. A composição do gás foi analisada cromatograficamente para todos os experimentos a fim de determinarmos o poder calorífico do gás, as parcelas de energia de cada componente na mistura do gás resultante, a potência calorífica do gaseificador. Com relação a composição do gás de ar, devido as nossas condições ambientais a gaseificação comportou-se como se fosse uma composição de gás d'água apresentando em sua análise parcelas de hidrogênio e metano proporcionando assim um aumento no poder calorífico do gás e consequentemente aumento da potência calorífica do gaseificador. / The research subject proposed in this study is based on an examination of the parameters significant for the process of ascendent and counter-current gasification. The gasifier which was utilized was a module proto type. The lower module has an extenal diameter of 50 cm and an internail diameter of 42 cm, owing to the refractory and to the double walls designed for the heating of the incoming air. The upper module with an external diameter of 55 cm and an internal diameter of 50,6 cm, is similarly made of double walls in view of the extraction of gas being localized at different The two modules are joined to each other in such a way as to enable a variation in the height of the charging of the gasifier, as well as in the height of the outgoing gas. The process of gasification used in the study was that of air gas or low-BTU gas. The study was divided into two geometries by varying be tween them, the relation of the height of the outgoing gas and the diameter of the gasifier. When gas was extracted by the upper perforation with a relation δ = 3,09 it is denominated upper geometry andwhen δ=214, lower geometry. Five experimento involving different escapes of air were made for each of the geometries. Temperatus were measured at three different points of the gasifier in order to ascertain the behavior of the reaction zones according to the temperatures. The flows of air, gas, gasified coal and steam contained in the air were measured so that the analyses were made in terms of dimensional parameters. The composition of the gas was analyses chromografically in all the experiments undertaken, so as to determine the calorific potential of the gas, the percent of energy in each component of the resultant mixed gas, and the calorific power of the gasifier. In relation to the composition of air gas, the gasification behaved as if it were a mixture of water gas, owing to local ambiental condition. The composition presented, on analysis, parts of hydrogen and methane, thus contributing to an increase in the heating power of the gas and consequently, an increase in the heating potential of the gasifier.
|
74 |
Análise da resistência a corrosão do aço carbono revestido com Al55-Zn após deformação mecânica e tratamento térmicoBESERRA, Antonio Adelmo Freire 12 January 2001 (has links)
Submitted by Edisangela Bastos (edisangela@ufpa.br) on 2018-03-28T17:05:06Z
No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Tese_AnaliseResistenciaCorrosao.pdf: 6473132 bytes, checksum: 4a83f2ee43a0dcb1257ada308b39c480 (MD5) / Approved for entry into archive by Edisangela Bastos (edisangela@ufpa.br) on 2018-04-02T15:15:36Z (GMT) No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Tese_AnaliseResistenciaCorrosao.pdf: 6473132 bytes, checksum: 4a83f2ee43a0dcb1257ada308b39c480 (MD5) / Made available in DSpace on 2018-04-02T15:15:36Z (GMT). No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Tese_AnaliseResistenciaCorrosao.pdf: 6473132 bytes, checksum: 4a83f2ee43a0dcb1257ada308b39c480 (MD5)
Previous issue date: 2001-01-12 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O revestimento de Al55-Zn apresenta uma resistência à corrosão atmosférica em média doze vezes superior à do revestimento galvanizado. Entretanto, após deformação mecânica, o revestimento de Al55-Zn apresenta microtrincas que comprometem a sua resistência à corrosão. Neste trabalho estudou-se a variação na resistência à corrosão do revestimento de Al55-Zn após deformação sob tração ou dobramento e a influência de tratamentos térmicos a '200 GRAUS' e a '360 GRAUS' durante 16h na resistência à corrosão do revestimento antes e depois das deformações. Para isso, um grupo de amostras do material foi deformado sob tensão de tração até 10% ou 15% de seu comprimento inicial e outro grupo foi dobrado até '90 GRAUS' ou '180 GRAUS'. A variação na resistência à corrosão do revestimento foi analisada através das técnicas de extrapolação de Tafel e de espectroscopia de impedância eletroquímica. Como resultado, observou-se que tanto a deformação axial quanto o dobramento do material reduzem a sua resistência à corrosão. Após o tratamento térmico a '360 GRAUS' as amostras deformadas até 10% ou 15% recuperaram a sua resistência à corrosão, entretanto, as amostras dobradas até '90 GRAUS' ou '180 GRAUS' apresentaram apenas uma recuperação parcial na sua resistência à corrosão após os tratamentos térmicos. / Analysis of the corrosion resistance of the 55AI-Zn coating on carbon steel after mechanical deformation and heat treatment The atmospheric corrosion resistance of 55%Al-Zn alloy coating on average is twelve times that of an equal thickness of galvanized coating. However, it has been shown that microcracks were observed at all levels of strain under simple uniaxial tension. Our research has been focused on determining the degree of corrosion experienced by these coatings after deformation under simple tension or bending and how much the heat treatment at '200 DEGREES' or '360 DEGREES' for 16h can influence the corrosion resistance of the coating. The coated sheet samples were strained to 10% or 15% engineering strain while another group of samples was bent to bend angles of '90 DEGREES' or '180 DEGREES'. The corrosion resistance of the samples was evaluated trhough Tafel extrapolation and electrochemical impedance spectroscopy methods. As a result, it was observed that both the straining and the bending of the coating reduces its corrosion resistance. After the heat treatment at '360 DEGREES' the samples strained to 10% or 15% recover their corrosion resistance, but the specimens bended to '90 DEGREES' or '180 DEGREES' recuperate only partially the corrosion resistance after the heat treatments.
|
75 |
Simulação de sistemas de simples estágios de refrigeração por compressão de vapor / Simulation refrigeration systems of single stage vapor compressionZIGMANTAS, Paulo Vitor de Matos 18 September 2006 (has links)
Submitted by Irvana Coutinho (irvana@ufpa.br) on 2012-05-29T12:40:21Z
No. of bitstreams: 2
Dissertacao_ZigmantasSimulacaoSistemasSimples.pdf: 2976848 bytes, checksum: c79813a200468f113de57854cc48e701 (MD5)
license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) / Approved for entry into archive by Irvana Coutinho(irvana@ufpa.br) on 2012-05-29T12:52:02Z (GMT) No. of bitstreams: 2
Dissertacao_ZigmantasSimulacaoSistemasSimples.pdf: 2976848 bytes, checksum: c79813a200468f113de57854cc48e701 (MD5)
license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) / Made available in DSpace on 2012-05-29T12:52:02Z (GMT). No. of bitstreams: 2
Dissertacao_ZigmantasSimulacaoSistemasSimples.pdf: 2976848 bytes, checksum: c79813a200468f113de57854cc48e701 (MD5)
license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5)
Previous issue date: 2006 / Na atualidade, o estudo do desempenho térmico de um sistema de refrigeração por compressão de vapor representa uma ferramenta importante no auxílio do desenvolvimento de novos produtos ou melhoria dos já existentes. Um modelo de simulação em regime permanente foi elaborado para avaliar o desempenho do sistema frigorífico. O sistema estudado inclui uma Central de Ar Condicionado, modelo PA HILTON, constituída de um compressor alternativo do tipo semi-hermético, evaporador e condensador compacto de tubos e aletas e uma válvula de expansão termostática. O modelo do condensador considera três regiões distintas de troca de calor as quais são respectivamente a região de dessuperaquecimento, condensação e subresfriamento. Para a modelagem do evaporador, foram consideradas as regiões de evaporação e superaquecimento. No modelo de simulação foram utilizadas correlações adequadas para a estimativa dos coeficientes de transferência de calor e perda de pressão para cada região do evaporador e condensador. Não foram consideradas a transferência de calor e queda de pressão nas linhas de conexão entre os componentes. A solução do sistema de equações não lineares resultantes da modelagem matemática dos componentes do sistema simulado foi obtida utilizando-se o método das substituições sucessivas com o emprego do software Engineenng Equation Solver . Os resultados obtidos pelo modelo de simulação apresentaram erros inferiores a 9% em relação aos valores experimentais. / Nowadays, the thermal performance of refrigeration systems of vapor compression is a very important toll to aid on the development of News Products or Upgrading them. A steady state simulation model is presented to estimate the refrigeration systems performance.The studied system considers a air conditioning equipment Model PA HILTON, that includes a semi-hermetic alternative compressor, a compact tube and fins evaporator and condenser and finally a thermostatic expansion valve. The condenser mathematical model takes account of three different regions of heat transfer : cooling, condensing and sub-cooling.The evaporator mathematical modeling considers the evaporating and superheated regions. Depending of the region studied, in the model simulated includes appropriate correlations of heat transfer and pressure droops. The heat transfer and pressure drop inside the lines between the components are not considered. The solution of non linear equation systems is obtained trough a interactive method using the Engineering Equation Solver Software. The comparations between experimental and simulated values shows a very good agreement.
|
76 |
ANÁLISE DOS IMPACTOS SÓCIO-ECONÔMICOS E AMBIENTAIS DAS INDÚSTRIAS DE CALÇADOS DA CIDADE DE CAMPINA GRANDE - PBFrança, Pollyanna Xavier Nunes 20 February 2006 (has links)
Made available in DSpace on 2015-09-25T12:23:30Z (GMT). No. of bitstreams: 1
POLLYANNA_XAVIER_NUNES_FRANCA_PDF.pdf: 493506 bytes, checksum: 623aec9335caa215b61a703092dbc7ac (MD5)
Previous issue date: 2006-02-20 / Since the appearance of the capitalist system until today, the industry has evolved
acceleratingly as much in relation to industrial process as in types and quantity of
product. Consequently, this has brought negative effects to the environment,
because of high consumption of raw material, causing shortage some times, as well
as causing the improper destination of the waste created during the production. This
research had as objective to analyse the socio-economical and environmental impact
of shoe industry of Campina Grande - PB. The study of the socio-economical aspects
aimed to investigate the number of companies, functional insertion condition, that is,
formal and informal conditions of the industries, number of jobs, income, among
others. The study of environmental aspects investigated the methods of treatment,
the final disposal of the solid waste of different kinds and quantities. The analysis of
these parameters was done with data collection through questionnaire, in each
company belonging to sampled universe, for future tabulation. After careful analysis
of the data it can be concluded that in this branch of the industrial activity, there
exists little concern with protection of the environment, seeing that a major part of the
solid waste produced by the industrial activity is destined to the open dumping sites.
This situation demonstrates the necessity for working with environmental
management tools which may reduce the environmental impacts by this industrial
sector. In relation to socio-economical question, it can be noticed that this kind of
industrial activity, specifically the case studied, still absorbs a large number of labor,
in spite of the significant presence of informal activity and low payment offered. / Desde o surgimento do sistema capitalista até os dias atuais, a indústria vem
evoluindo aceleradamente, tanto no que diz respeito ao processo industrial quanto
aos tipos e quantidades de produtos. Isso, consequentemente, tem trazido efeitos
negativos ao meio ambiente devido ao alto consumo da matéria-prima, levando à
escassez em alguns casos, como também ao destino indevido dos resíduos gerados
durante a produção. Essa pesquisa teve como objetivo analisar os impactos sócioeconômicos
e ambientais das indústrias de calçados instaladas no parque industrial
da cidade de Campina Grande, estado da Paraíba . O estudo dos aspectos sócioeconômicos
da pesquisa objetivou investigar a quantidade de empresas, condição
de inserção funcional, isto é, formalidade e informalidade das indústrias, quantidade
de emprego, renda, entre outros. O estudo dos aspectos ambientais objetivou
analisar os métodos de tratamento, a disposição final dos resíduos sólidos de
diferentes espécies e a quantidade dos resíduos gerados. Portanto, foi realizada a
aplicação de questionários nas empresas inseridas no universo amostral,
observação in loco do funcionamento rotineiro das empresas, além da análise de
dados cadastrais. Após uma criteriosa análise dos dados levantados, pode-se
concluir que, neste ramo de atividade industrial, não existem medidas efetivas de
ações norteadoras para a preservação ambiental, haja vista ter sido constatado que
grande parte dos resíduos sólidos gerados pelas atividades industriais ainda é
destinada para lixões a céu aberto. Esta situação demonstra a necessidade de se
trabalhar ferramentas de gestão ambiental que possibilitem a redução dos impactos
ambientais que este setor industrial vem causando ao meio ambiente. No tocante às
questões sócio-econômicas, pode-se perceber que este ramo de atividade industrial,
no caso específico estudado, ainda absorve um contingente razoável de mão de
obra, apesar da presença significativa da informalidade e da baixa remuneração
ofertada.
|
77 |
ANÁLISE DA VIABILIDADE DE FILTRO ANAERÓBIO DE CHICANAS NO PÓS-TRATAMENTO DE ESGOTOS SANITÁRIOSSilva, Vanessa Farias da 22 December 2005 (has links)
Made available in DSpace on 2015-09-25T12:23:30Z (GMT). No. of bitstreams: 1
VANESSA F SILVA.pdf: 1400231 bytes, checksum: fb9f24d41beb924c130d174f918f19f8 (MD5)
Previous issue date: 2005-12-22 / The objective of this thesis is to evaluate the performance of anaerobic filter with
baffles (FAC) for the post treatment of anaerobic effluent and using rings cut from
PET bottles as filling medium. The experiment was carried out in three phases
characterized by the hydraulic retention times of 7, 9 and 10 days, respectively. The
analysis of the UASB and FAC effluents was carried out weekly to evaluate the
removal efficiency of organic material expressed as BOD5 e COD, solids and its
different fractions, nutrients (nitrogen and phosphorus) and indicators of faecal
contamination (thermotolerant Coliforms). The results showed that there were no
significant differences between the FAC effluent during the three phases with
respect to organic material and suspended solids (at 5% significance level), but
there were differences in the electric conductivity, nitrogen and thermotolerant
Coliforms. The FAC presented good performance of organic material removal (65%
for COD and 64% for BOD5 during the first phase) and suspended solids (81% for
TSS and 83% for VSS during the first phase). Thus it can be noted that the FAC
presented good post treatment efficiency of anaerobic effluents, resulting in clarified
effluent with low concentrations of organic material (12mg BOD5.L-1), suspended
solids (<10 mg TSS. L-1) and turbidity (<10 UNT). With respect to sanitary quality
the produced effluent had concentrations of thermotolerant in the range of 103 to
104 UFC.100 mL-1, hence above the standards established by the WHO (1989) for
utilization in irrigation without restrictions. / O presente trabalho teve como objetivo avaliar o desempenho de filtro anaeróbio de
chicanas (FAC) no pós-tratamento de efluente anaeróbio, usando garrafas PET como
material de enchimento. O experimento foi realizado em três fases, delimitado pelos
três tempos de detenção hidráulicas, 7, 9 e 10 dias, respectivamente. As análises
dos efluentes do reator UASB e do FAC foram realizadas semanalmente,
averiguando a remoção de matéria orgânica na forma de DBO5 e DQO, sólidos e
suas frações, nutrientes (nitrogênio e fósforo) e indicadores de contaminação fecal
(coliformes termotolerantes). Os resultados mostraram que não ocorreram
diferenças significativas no efluente do FAC entre as três fases, em relação a
matéria orgânica e sólidos (ao nível de 5%), mas houve diferença quanto a
condutividade elétrica, nitrogênio e coliformes termotolerantes. O FAC apresentou
bom desempenho quanto à remoção de matéria orgânica (65% para DQO e 64%
para DBO5 durante a 1ª fase) e sólidos suspensos (81% para SST e 83% para SSV
durante a 1ª fase). Diante desses resultados, observa-se que o FAC apresentou boa
eficiência no pós-tratamento de efluente anaeróbio resultando em um efluente
clarificado com baixas concentrações de matéria orgânica (12mg DBO5.L-1), sólidos
suspensos (<10 mg SST. L-1) e turbidez (<10 UNT). Com relação à qualidade
sanitária, o efluente produzido apresentava concentrações de coliformes
termotolerantes variando de 103 a 104 UFC.100 mL-1, portanto valores acima dos
padrões estabelecidos pelo OMS (1989) para ser utilizado em irrigação irrestrita.
|
78 |
TRATAMENTO BIOLÓGICO DE EFLUENTES DE LAVA-JATOCosta, Maria José Comandante 21 February 2006 (has links)
Made available in DSpace on 2015-09-25T12:23:32Z (GMT). No. of bitstreams: 1
MARIA_JOSE_COMANDANTE_COSTA.pdf: 1369694 bytes, checksum: 2b63fa3023c60448918ab6ae6b29a54f (MD5)
Previous issue date: 2006-02-21 / The research was realized in four phases. In the 1st phase, interviews were accomplished with
proprietors of car-washes with the objective of knowing your environmental and social
impacts. In the 2nd phase synthetic effluents of car-washes were treated during 147 days in
batch anaerobic reactors with five different oil and detergent concentrations. In the 3rd phase
six reactors were monitored in batch form, during 20 days, with substrate containing high oil
concentrations (0,5 to 2,5 g.l-1) and surfactants concentrations (5,0g.L-1). These treatments
were realized with purpose to verified the relation between oil concentration and inhibition of
the biologic activity. In the 4th phase six batch anaerobic reactors, with different proportions
of the surfactant, were monitored during 35 days. The concentrations of organic matter
influent and effluent were analyzed in all the treatments and in the sludge were determined
solid concentration. Daily the biogas produced was measures and characterized. In the 2nd
phase the average removal of soluble COD was about 82%, for a monitoring period of 18
days. For raw COD during 100 days of operation the average removal was approximately
76% and the production of methane was directly proportional the substrate concentrations. It
was verified that the anaerobic biological activity occurs in surfactant concentration below
0,5 g.L-1, and starting from that concentration it begins to happen inhibition of the process. / O presente trabalho foi desenvolvido em quatro fases. A primeira fase teve o objetivo de
levantar dados sobre os impactos ambientais e sociais causados pelos lava-jatos. Para tanto,
foram realizadas entrevistas com seus proprietários. Na segunda fase, foram tratados
anaerobiamente, durante 147 dias, em reatores de batelada, efluentes sintéticos de lava-jatos
com cinco diferentes concentrações de óleo e detergente. Na terceira fase, foram monitorados
seis reatores anaeróbios, em regime de batelada, durante 20 dias, com substratos contendo
altas concentrações de óleo (0,5 a 2,5 g.L-1) e surfactantes (5,0 g.L-1). Estes tratamentos
tiveram por finalidade verificar se, com o aumento da concentração de óleo, haveria inibição
da atividade biológica. Na quarta fase, foram realizados, anaerobiamente, em reatores de
batelada, durante 35 dias, seis experimentos com diferentes concentrações de surfactante para
verificar que concentração inibiria o processo biológico anaeróbio. Para todos os tratamentos
foram analisadas as concentrações de matéria orgânica (DQO) afluente e efluente, bem como
as concentrações de sólidos do lodo. Diariamente, foram realizadas leituras do volume e da
composição do biogás. Como resultados da segunda fase, verificaram-se remoções de DQO
solúvel média de 82% aos 18 dias e para DQO bruta em torno de 76% para os cinco
tratamentos, durante 100 dias de operação. A produção de metano foi diretamente
proporcional às concentrações dos substratos. Constatou-se que a atividade biológica
anaeróbia ocorre numa concentração de surfactante de até aproximadamente 0,5 g.L-1, sendo
que a partir daí, começa a ocorrer inibição do processo.
|
79 |
FOTOCATÁLISE HETEROGÊNEA NO POLIMENTO DE EFLUENTES SINTÉTICOS DE CURTUME: alternativa para minimizar impactos ambientaisPascoal, Salomão de Andrade 23 February 2006 (has links)
Made available in DSpace on 2015-09-25T12:23:36Z (GMT). No. of bitstreams: 1
SALOMAO_DE_ANDRADE_PASCOAL.pdf: 1571379 bytes, checksum: 8dcb3d302822615da27bf933016a3cef (MD5)
Previous issue date: 2006-02-23 / The industry is a section of the contemporary society with great pollutant potential of the
environment, especially of the aquatic ecosystems. The tanning industries are big producing of
dejections with significant amounts of organic matter and of chrome. The conventional processes
of treatment applied those dejections, not always they possess good effectiveness. Actuality, the
Advanced Oxidation Processes represent an excellent alternative of tertiary treatment. In the
present study, the application of the heterogeneous photocatalysis was evaluated, being used a
photocatalyst (TiO2) immobilized, in the tertiary treatment of synthetic liquid effluents
representative of tanning industries. It was aimed at to remove Cr(VI) and organic matter. The
photocatalytic reactor was of the type Fixed Bed of Fine Film, built with a plate of glass arrayed
for the fixation of TiO2. It was adopted as radiation sources, the sun and lamps issuing of UV
radiation (l= 250 nm). The smallest values of removal effectiveness for Cr(VI) they were of 62%
and 51% and of DOC they were from 60% and 53% to the experiments done with radiation UV
originating from of the sun and of lamps, respectively. The results of the parameters related to the
reduction phases and oxidation of the heterogeneous photocatalysis, they showed that the
exhibition in the sun, he/she has effectiveness of larger relative removal than the exhibition to
UV lamps. The data of relative removal of Cr(VI) and of DOC and the constants kinetics of these
parameters, they indicated that the adopted experimental configurations optimized the phase of
reduction of the heterogeneous photocatalysis. / A indústria é um setor da sociedade contemporânea com grande potencial poluidor do meio
ambiente, especialmente dos ecossistemas aquáticos. As indústrias de curtume são grandes
produtoras de dejetos com significativas quantidades de material orgânico e de cromo. Os
processos convencionais de tratamento aplicados a esses dejetos, nem sempre possuem boa
eficácia. Atualmente, os Processos Oxidativos Avançados representam uma excelente alternativa
de tratamento terciário. No presente estudo, avaliou-se a aplicação da fotocatálise heterogênea,
usando-se um fotocatalisador (TiO2) imobilizado, no tratamento final de efluentes líquidos
sintéticos representativos de indústrias de curtume. Objetivou-se remover Cr(VI) e matéria
orgânica. O fotorreator foi do tipo Leito Fixo de Filme Fino, construído com uma placa de vidro
jateado para a fixação do TiO2. Adotou-se como fontes de radiação, o sol e lâmpadas germicidas
emissoras de radiação UV (l= 250 nm). Os menores valores de eficácia de remoção para Cr(VI)
foram de 62% e 51% e de DQO foram de 60% e 53% para os experimentos feitos com radiação
UV oriundas do sol e de lâmpadas, respectivamente. Os resultados dos parâmetros relacionados
às fases de redução e oxidação da fotocatálise heterogênea, mostraram que a exposição ao sol,
tem eficácia de remoção relativa maior do que a exposição à lâmpadas UV. Os dados de remoção
relativa de Cr(VI) e de DQO e as constantes cinéticas destes parâmetros, indicaram que as
configurações experimentais adotadas otimizaram a fase de redução da fotocatálise heterogênea.
|
80 |
Análise computacional dos campos de velocidade e temperatura do ambiente interno da usina termelétrica Santana - AmapáOLIVEIRA FILHO, Álvaro Henriques de 07 August 2008 (has links)
Submitted by Cleide Dantas (cleidedantas@ufpa.br) on 2014-04-07T13:52:52Z
No. of bitstreams: 2
license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5)
Dissertacao_AnaliseComputacionalCampos.pdf: 8199135 bytes, checksum: 4e41ee450e20c1b754db24b43b82d5fa (MD5) / Approved for entry into archive by Ana Rosa Silva (arosa@ufpa.br) on 2014-06-16T13:18:05Z (GMT) No. of bitstreams: 2
license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5)
Dissertacao_AnaliseComputacionalCampos.pdf: 8199135 bytes, checksum: 4e41ee450e20c1b754db24b43b82d5fa (MD5) / Made available in DSpace on 2014-06-16T13:18:05Z (GMT). No. of bitstreams: 2
license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5)
Dissertacao_AnaliseComputacionalCampos.pdf: 8199135 bytes, checksum: 4e41ee450e20c1b754db24b43b82d5fa (MD5)
Previous issue date: 2008 / A simulação numérica do escoamento de ar em ambientes internos é na atualidade o método mais apropriado para análise de conforto térmico em ambientes internos. O escoamento de ar nesses ambientes configura-se como um escoamento complexo, pois, em
regra geral, é uma combinação de escoamentos cisalhantes livres (jatos) e cisalhantes de
parede, além disso, esses escoamentos são governados por forças de inércia e forças de
empuxo, caracterizando-o como de convecção mista. A combinação desses mecanismos
cria um escoamento com características complexas, como zonas de recirculação, vórtices,
descolamento e recolamento de camada-limite dentre outras. Portanto, a precisão da solução estará diretamente ligada, principalmente, na habilidade do modelo de turbulência
adotado de reproduzir as características turbulentas do escoamento de ar e da transferência térmica. O objetivo principal do presente trabalho foi a simulação computacional do ambiente térmico interno do galpão que abriga os geradores e motores Wärtzilä da Usina
Termelétrica Santana no estado do Amapá. A formulação matemática baseada na solução
das equações gerais de conservação inclui uma análise dos principais modelos de
turbulência aplicados ao escoamento de ar em ambientes internos, assim como os processos de transferência de calor associados. Na modelagem numérica o método de volumes finitos é usado na discretização das equações de conservação, através do código
comercial Fluent-Airpak, que foi usado nas simulações computacionais para a análise dos
campos de velocidade e temperatura do ar. A utilização correta do programa computacional
foi testada e validada para o problema através da simulação precisa de casos retirados da
literatura. Os resultados numéricos foram comparados a dados obtidos de medições
experimentais realizados no galpão e apresentou boa concordância, considerando a
complexidade do problema simulado, o objetivo da simulação em face da diminuição da
temperatura no interior do galpão e, também, em função das limitações encontradas quando
da tomada das medições experimentais. Além disso, foram feitas simulações de estratégias
de melhoria do ambiente térmico da Usina, baseadas na realidade levantada e nos
resultados da simulação numérica. Finalmente, foram realizadas simulações do protótipo de
solução proposto para a diminuição da temperatura interna do galpão o que possibilitará um
aumento, na faixa de 20 a 30%, do tempo de permanência no interior do galpão. / The numerical simulation of the airflow in internal environments is in the present time the
most appropriate method for analysis of thermal comfort indoors. The airflow in these
environments is configured as a complex one, therefore, in general, it is a combination of
free-shear flow (jet) and of wall-shear flow, moreover, these are governed by inertia and
buoyancy forces, characterizing a situation of mixing convection. The combination of these
mechanisms creates an airflow with complex characteristics, as recirculation zones, vortices,
detachment and re-attachment of boundary layer amongst others. Therefore, the precision of
the solution will be directly connected, mainly, with the ability of the adopted turbulence
model to reproduce the turbulent characteristics of the airflow and thermal transfers. The
main objective of the present work was the computational simulation of the internal thermal
environment of the enclosure which shelters the generators and the Wärtzilä engines of the
thermo-electric power plant of Santana in the state of Amapá (Brazil). The mathematical
formulation based on the solution of the general equations of conservation includes an
analysis of the principal models of turbulence applied to the airflow inside the enclosure, as
well as the heat transfer processes associated. The finite-volume numerical method is used
in the discretization of the conservation equations, through the Fluent-Airpak software, for the
analysis of the distribution of air velocity and temperature fields. The correct use of the
software was tested and validated by successfully simulating problems solved by other
authors. The numerical results of the airflow in the enclosure were compared with the
experimental data and presented a good agreement, by considering the complexity of the
simulated problem and the limitations and difficulties found during measurements. Moreover,
simulations are presented of strategies for improvement of the thermal environment, based
on the actual reality and on the results of the numerical simulations. Finally, simulations of a
prototype solution are presented with the reduction of the internal temperature in the
enclosure. This solution allows an increase of the exposure time inside the enclosure, from
20 up to 30%, and improves the thermal comfort of the thermo-electric power plant.
|
Page generated in 0.1102 seconds