• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 16
  • Tagged with
  • 16
  • 16
  • 16
  • 16
  • 16
  • 14
  • 10
  • 10
  • 8
  • 8
  • 4
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

A influência da ventilação no molde da prótese auditiva retro-auricular para o controle do zumbido: ensaio clínico randomizado cego crossover / The influence of the BTE hearing aid earmold ventilation on tinnitus control: randomized crossover blind clinical trial

Santos, Gisele Munhoes dos 10 August 2005 (has links)
Introdução: Muitos pacientes com zumbido também apresentam algum grau de perda auditiva associada e o uso de próteses auditivas pode ser uma boa opção para melhorar ambos os sintomas. Porém, na prática clínica, a oclusão do meato acústico externo pelo molde da prótese auditiva pode até piorar o zumbido em alguns casos. A literatura apresenta poucos estudos sobre a real influência da ventilação do molde da prótese auditiva na percepção do zumbido. Objetivo: avaliar a resposta do zumbido à prótese auditiva retro-auricular com dois tipos de ventilação no molde (molde aberto e ventilação de alívio) em pacientes com perda auditiva neurossensorial simétrica após um mês de uso. Métodos: 50 pacientes atendidos no Grupo de Pesquisa em Zumbido com zumbido bilateral e perda auditiva neurossensorial simétrica de grau leve a severo foram submetidos a um ensaio clínico randomizado cego crossover. Destes, 26 pacientes iniciaram o ensaio utilizando próteses auditivas com molde aberto (ventilação de 4mm) e 24 iniciaram usando molde com ventilação de alívio (ventilação de 1mm). Após 30 dias de teste com o primeiro tipo de molde e um período de wash-out (15 dias), o tipo de molde foi trocado e o segundo molde foi usado por mais 30 dias. O zumbido foi avaliado de modo qualitativo (classificado em melhora, inalterado e piora) e quantitativo (variação de 0 a 10 de uma escala numérica). Resultados: A melhora do zumbido foi observada em 82% dos casos com pelo menos um tipo de molde e não houve diferença significante na diminuição do incômodo com o zumbido nas avaliações qualitativa e quantitativa com ambos os moldes. Apesar disto, 66% dos pacientes preferiram o molde aberto. Conclusão: A curto prazo, a melhora do zumbido por meio da prótese auditiva em pacientes com perda auditiva neurossensorial simétrica de grau leve a severo não depende do tamanho da ventilação do molde auricular / Introduction: Most tinnitus patients also have some degree of associated hearing loss, and the use of hearing aids is an option to improve both symptoms. In daily practice, the occlusion of the external meatus by the earmold during hearing aids fitting may enhance the tinnitus perception. However, the literature lacks studies about the real influence of the earmold ventilation on tinnitus perception. Objective: to evaluate the tinnitus response to the BTE hearing aids using two types of ventilation (open mold and relief ventilation) in patients with symmetric sensorineural hearing loss after one month usage. Methods: 50 patients attended in our Tinnitus Clinic who presented bilateral tinnitus and mild to severe symmetric sensorineural hearing loss underwent a randomized blind crossover clinical trial. Among them, 26 first used BTE hearing aids with open molds (4mm ventilation) and 24 first used hearing aids with relief ventilation mold (1mm ventilation). After 30 days using the first mold and a 15-day wash-out period, the type of earmold was changed in a crossover way and the second mold was used for another 30-day-period. Tinnitus evaluation was performed by a qualitative way (classified in improvement, unchanged and worsening) and by a quantitative way (variation of a numeric scale from 0 to 10). Results: Tinnitus improvement was observed by 82% of the patients with at least one type of earmold and there was no significant difference in the decrease of tinnitus discomfort by both, quantitative and qualitative evaluation. Despite the similar tinnitus control, 66% of the patients preferred to acquire the hearing aids with open mold. Conclusion: In a short-term evaluation, the tinnitus improvement by the use of hearing aids in patients with mild to severe symmetric sensorineural hearing loss does not depend on the size of earmold ventilation
2

A influência da ventilação no molde da prótese auditiva retro-auricular para o controle do zumbido: ensaio clínico randomizado cego crossover / The influence of the BTE hearing aid earmold ventilation on tinnitus control: randomized crossover blind clinical trial

Gisele Munhoes dos Santos 10 August 2005 (has links)
Introdução: Muitos pacientes com zumbido também apresentam algum grau de perda auditiva associada e o uso de próteses auditivas pode ser uma boa opção para melhorar ambos os sintomas. Porém, na prática clínica, a oclusão do meato acústico externo pelo molde da prótese auditiva pode até piorar o zumbido em alguns casos. A literatura apresenta poucos estudos sobre a real influência da ventilação do molde da prótese auditiva na percepção do zumbido. Objetivo: avaliar a resposta do zumbido à prótese auditiva retro-auricular com dois tipos de ventilação no molde (molde aberto e ventilação de alívio) em pacientes com perda auditiva neurossensorial simétrica após um mês de uso. Métodos: 50 pacientes atendidos no Grupo de Pesquisa em Zumbido com zumbido bilateral e perda auditiva neurossensorial simétrica de grau leve a severo foram submetidos a um ensaio clínico randomizado cego crossover. Destes, 26 pacientes iniciaram o ensaio utilizando próteses auditivas com molde aberto (ventilação de 4mm) e 24 iniciaram usando molde com ventilação de alívio (ventilação de 1mm). Após 30 dias de teste com o primeiro tipo de molde e um período de wash-out (15 dias), o tipo de molde foi trocado e o segundo molde foi usado por mais 30 dias. O zumbido foi avaliado de modo qualitativo (classificado em melhora, inalterado e piora) e quantitativo (variação de 0 a 10 de uma escala numérica). Resultados: A melhora do zumbido foi observada em 82% dos casos com pelo menos um tipo de molde e não houve diferença significante na diminuição do incômodo com o zumbido nas avaliações qualitativa e quantitativa com ambos os moldes. Apesar disto, 66% dos pacientes preferiram o molde aberto. Conclusão: A curto prazo, a melhora do zumbido por meio da prótese auditiva em pacientes com perda auditiva neurossensorial simétrica de grau leve a severo não depende do tamanho da ventilação do molde auricular / Introduction: Most tinnitus patients also have some degree of associated hearing loss, and the use of hearing aids is an option to improve both symptoms. In daily practice, the occlusion of the external meatus by the earmold during hearing aids fitting may enhance the tinnitus perception. However, the literature lacks studies about the real influence of the earmold ventilation on tinnitus perception. Objective: to evaluate the tinnitus response to the BTE hearing aids using two types of ventilation (open mold and relief ventilation) in patients with symmetric sensorineural hearing loss after one month usage. Methods: 50 patients attended in our Tinnitus Clinic who presented bilateral tinnitus and mild to severe symmetric sensorineural hearing loss underwent a randomized blind crossover clinical trial. Among them, 26 first used BTE hearing aids with open molds (4mm ventilation) and 24 first used hearing aids with relief ventilation mold (1mm ventilation). After 30 days using the first mold and a 15-day wash-out period, the type of earmold was changed in a crossover way and the second mold was used for another 30-day-period. Tinnitus evaluation was performed by a qualitative way (classified in improvement, unchanged and worsening) and by a quantitative way (variation of a numeric scale from 0 to 10). Results: Tinnitus improvement was observed by 82% of the patients with at least one type of earmold and there was no significant difference in the decrease of tinnitus discomfort by both, quantitative and qualitative evaluation. Despite the similar tinnitus control, 66% of the patients preferred to acquire the hearing aids with open mold. Conclusion: In a short-term evaluation, the tinnitus improvement by the use of hearing aids in patients with mild to severe symmetric sensorineural hearing loss does not depend on the size of earmold ventilation
3

A influência do gerador de som associado à amplicação convencional para o controle do zumbido: ensaio clínico cego randomizado / The influence of sound generator associated with conventional amplification for tinnitus control: randomized blind clinical trial

Santos, Gisele Munhoes dos 19 September 2013 (has links)
Introdução: O zumbido é um sintoma que acomete cerca de 10% da população e pode prejudicar bastante a qualidade de vida, sendo considerado um importante problema de saúde pública mundial. Os modelos fisiopatológicos atuais do zumbido consideram que a compensação da perda auditiva poderia prevenir ou reverter mudanças no córtex auditivo central acerca do zumbido. Próteses auditivas com gerador de som integrado têm sido utilizadas como alternativa para potencializar o tratamento do zumbido nos pacientes com perda auditiva associada. Contudo, não existe evidência científica suficiente para suportar a superioridade do uso combinado de ferramentas em relação à amplificação convencional. Objetivo: verificar se o uso combinado de amplificação e gerador de som é mais eficaz do que somente amplificação na redução do incômodo com o zumbido em pacientes com zumbido e perda auditiva neurossensorial bilateral simétrica de grau leve a moderado. Métodos: 49 pacientes com zumbido e perda auditiva participaram de um ensaio clínico cego randomizado. Um grupo foi adaptado bilateralmente com uso combinado de amplificação e gerador de som e o outro grupo foi adaptado somente com amplificação. O incômodo com o zumbido foi medido pelo THI e escala numérica. As medidas psicoacústicas do zumbido também foram realizadas. As avaliações inicial e final foram realizadas por um avaliador cego. Resultados: Após três meses, no grupo da adaptação combinada, 62,5% dos pacientes apresentaram redução do incômodo com o zumbido e no grupo da adaptação simples, 78%, sem diferença estatisticamente significante entre os grupos. Para o THI, escala numérica e intensidade sonora de zumbido, detectou-se efeito do nível mínimo de mascaramento, em que maiores valores de nível mínimo de mascaramento estão associados a maior incômodo e maior intensidade do zumbido. Conclusão: O uso combinado de amplificação e gerador de som e o uso de amplificação convencional foram igualmente eficazes na redução do incômodo com o zumbido / Introduction: Tinnitus is a symptom that affects about 10% of the population and can greatly impair the quality of life. In fact, it is considered as an important public health problem worldwide. The current pathophysiological models of tinnitus consider that the compensation of hearing loss could prevent or reverse changes in the auditory cortex. Hearing aids with an integrated sound generator have been used as an alternative to enhance the treatment of tinnitus in patients with hearing loss. However, there is no sufficient scientific evidence to support the superiority of the combined use of sound generator and amplification compared to conventional amplification alone. Objective: to verify whether the combined use of amplification and sound generator is more effective than amplification alone in reducing bothersome tinnitus in patients with mild to moderate bilaterally symmetrical sensorineural hearing loss. Methods: 49 patients with tinnitus and hearing loss underwent a blind randomized clinical trial. One group was bilaterally fitted with the combined use of amplification and sound generator, and the other group was fitted with amplification alone. The tinnitus annoyance was measured by THI and numerical scale. Psychoacoustic measurements of tinnitus were also performed. The initial and final assessments were performed by a blinded evaluator. Results: After 3 months, 62.5% of patients showed a reduction in tinnitus annoyance in the group of the combined use of amplification and sound generator, and 78% in the group with amplification alone, with no significant difference between the groups. For THI, numeric scale and tinnitus loudness, it was detected an effect of the MML, where higher values of MML are associated with greater discomfort due to tinnitus. Conclusion: The combined use of amplification and sound generator and the use of conventional amplification alone were equally effective in reducing tinnitus annoyance
4

A influência do gerador de som associado à amplicação convencional para o controle do zumbido: ensaio clínico cego randomizado / The influence of sound generator associated with conventional amplification for tinnitus control: randomized blind clinical trial

Gisele Munhoes dos Santos 19 September 2013 (has links)
Introdução: O zumbido é um sintoma que acomete cerca de 10% da população e pode prejudicar bastante a qualidade de vida, sendo considerado um importante problema de saúde pública mundial. Os modelos fisiopatológicos atuais do zumbido consideram que a compensação da perda auditiva poderia prevenir ou reverter mudanças no córtex auditivo central acerca do zumbido. Próteses auditivas com gerador de som integrado têm sido utilizadas como alternativa para potencializar o tratamento do zumbido nos pacientes com perda auditiva associada. Contudo, não existe evidência científica suficiente para suportar a superioridade do uso combinado de ferramentas em relação à amplificação convencional. Objetivo: verificar se o uso combinado de amplificação e gerador de som é mais eficaz do que somente amplificação na redução do incômodo com o zumbido em pacientes com zumbido e perda auditiva neurossensorial bilateral simétrica de grau leve a moderado. Métodos: 49 pacientes com zumbido e perda auditiva participaram de um ensaio clínico cego randomizado. Um grupo foi adaptado bilateralmente com uso combinado de amplificação e gerador de som e o outro grupo foi adaptado somente com amplificação. O incômodo com o zumbido foi medido pelo THI e escala numérica. As medidas psicoacústicas do zumbido também foram realizadas. As avaliações inicial e final foram realizadas por um avaliador cego. Resultados: Após três meses, no grupo da adaptação combinada, 62,5% dos pacientes apresentaram redução do incômodo com o zumbido e no grupo da adaptação simples, 78%, sem diferença estatisticamente significante entre os grupos. Para o THI, escala numérica e intensidade sonora de zumbido, detectou-se efeito do nível mínimo de mascaramento, em que maiores valores de nível mínimo de mascaramento estão associados a maior incômodo e maior intensidade do zumbido. Conclusão: O uso combinado de amplificação e gerador de som e o uso de amplificação convencional foram igualmente eficazes na redução do incômodo com o zumbido / Introduction: Tinnitus is a symptom that affects about 10% of the population and can greatly impair the quality of life. In fact, it is considered as an important public health problem worldwide. The current pathophysiological models of tinnitus consider that the compensation of hearing loss could prevent or reverse changes in the auditory cortex. Hearing aids with an integrated sound generator have been used as an alternative to enhance the treatment of tinnitus in patients with hearing loss. However, there is no sufficient scientific evidence to support the superiority of the combined use of sound generator and amplification compared to conventional amplification alone. Objective: to verify whether the combined use of amplification and sound generator is more effective than amplification alone in reducing bothersome tinnitus in patients with mild to moderate bilaterally symmetrical sensorineural hearing loss. Methods: 49 patients with tinnitus and hearing loss underwent a blind randomized clinical trial. One group was bilaterally fitted with the combined use of amplification and sound generator, and the other group was fitted with amplification alone. The tinnitus annoyance was measured by THI and numerical scale. Psychoacoustic measurements of tinnitus were also performed. The initial and final assessments were performed by a blinded evaluator. Results: After 3 months, 62.5% of patients showed a reduction in tinnitus annoyance in the group of the combined use of amplification and sound generator, and 78% in the group with amplification alone, with no significant difference between the groups. For THI, numeric scale and tinnitus loudness, it was detected an effect of the MML, where higher values of MML are associated with greater discomfort due to tinnitus. Conclusion: The combined use of amplification and sound generator and the use of conventional amplification alone were equally effective in reducing tinnitus annoyance
5

Ablação do istmo cavo-tricuspídeo para controle do flutter atrial: estudo prospectivo e randomizado comparando eficácia e segurança de cateter irrigado com cateter de 8 mm. / Cavotricuspid isthmus ablation for the treatment of atrial flutter: prospective randomized study comparing efficacy and safety of cooled-tip versus 8-mm-tip catheters.

Melo, Sissy Lara 21 February 2005 (has links)
O cateter irrigado foi comparado com o de 8 mm para ablação com radiofrequência do istmo cavo-tricuspídeo(Ist-CT). Foram randomizados 52 pacientes portadores de flutter atrial típico para ablação com cateter irrigado(grupoI) ou com cateter de 8 mm(grupo II). O bloqueio do Ist-CT foi obtido em 51 pacientes. Não houve diferença estatística em relação aos parâmetros de aplicação de RF entre os dois grupos. A ablação do Ist-CT com cateter irrigado versus cateter de 8mm foi igualmente eficaz e segura no controle do flutter atrial típico. / A 4-mm cooled tip catheter was compared to an 8-mm tip catheter to cavotricuspid isthmus(CTI) ablation. This prospective study enrolled 52 patients with typical atrial flutter to ablation with a closed cooled-tip catheter(group1) or an 8-mm tip catheter. Radiofrequency(RF) applications were performed to achieve complete CTI block wich was achieved in 51 patients. No significant differences were found in the procedure parameters. CTI ablation with an irrigated tip catheter versus an 8-mm tip catheter was equally effective and satisfactorily safe for ablation of typical atrial flutter.
6

"Ensaio clínico controlado randomizado aberto com metil-prednisolona em portadores de mielopatia associada ao HTLV-1 paraparesia espástica tropical" / Clinical controlled randomized open trial with methylprednisolone in myelopathy associated to HTLV-1 / tropical spastic paraparesis

Tauil, Carlos Bernardo 23 March 2004 (has links)
Estudamos a avaliação clínica de longo termo da resposta de pacientes com diagnóstico precoce de HAM/TSP ao tratamento com metil-prednisolona. Objetivamos pesquisar em relação ao tempo de evolução e apresentação da doença a eficácia deste tratamento. Realizamos o acompanhamento dos pacientes utilizando como parâmetros as escalas de critérios clínicos de Osame e Kurtzke e comparamos com um grupo controle que não recebeu este tipo de tratamento.Os pacientes do grupo experimental e do grupo controle que realizaram fisioterapia mantiveram-se estáveis ou obtiveram melhora de alguns sintomas da doença / We studied the long-term clinical response of patients with early diagnoses of HAM/TSP to treatment with methylprednisolone. The aim was to study this treatment in relation to the time of evolution and presentation of the disease and its effectiveness. The patients were followed using the scales of clinical criteria by Osame and Kurtzke, and compared with a control group of patients who did not receive this treatment type. We observed that patients in the experimental group and the control group, having been followed up with physiotherapy, either remained stable or presented improvement for some symptoms of the disease
7

Ablação do istmo cavo-tricuspídeo para controle do flutter atrial: estudo prospectivo e randomizado comparando eficácia e segurança de cateter irrigado com cateter de 8 mm. / Cavotricuspid isthmus ablation for the treatment of atrial flutter: prospective randomized study comparing efficacy and safety of cooled-tip versus 8-mm-tip catheters.

Sissy Lara Melo 21 February 2005 (has links)
O cateter irrigado foi comparado com o de 8 mm para ablação com radiofrequência do istmo cavo-tricuspídeo(Ist-CT). Foram randomizados 52 pacientes portadores de flutter atrial típico para ablação com cateter irrigado(grupoI) ou com cateter de 8 mm(grupo II). O bloqueio do Ist-CT foi obtido em 51 pacientes. Não houve diferença estatística em relação aos parâmetros de aplicação de RF entre os dois grupos. A ablação do Ist-CT com cateter irrigado versus cateter de 8mm foi igualmente eficaz e segura no controle do flutter atrial típico. / A 4-mm cooled tip catheter was compared to an 8-mm tip catheter to cavotricuspid isthmus(CTI) ablation. This prospective study enrolled 52 patients with typical atrial flutter to ablation with a closed cooled-tip catheter(group1) or an 8-mm tip catheter. Radiofrequency(RF) applications were performed to achieve complete CTI block wich was achieved in 51 patients. No significant differences were found in the procedure parameters. CTI ablation with an irrigated tip catheter versus an 8-mm tip catheter was equally effective and satisfactorily safe for ablation of typical atrial flutter.
8

"Ensaio clínico controlado randomizado aberto com metil-prednisolona em portadores de mielopatia associada ao HTLV-1 paraparesia espástica tropical" / Clinical controlled randomized open trial with methylprednisolone in myelopathy associated to HTLV-1 / tropical spastic paraparesis

Carlos Bernardo Tauil 23 March 2004 (has links)
Estudamos a avaliação clínica de longo termo da resposta de pacientes com diagnóstico precoce de HAM/TSP ao tratamento com metil-prednisolona. Objetivamos pesquisar em relação ao tempo de evolução e apresentação da doença a eficácia deste tratamento. Realizamos o acompanhamento dos pacientes utilizando como parâmetros as escalas de critérios clínicos de Osame e Kurtzke e comparamos com um grupo controle que não recebeu este tipo de tratamento.Os pacientes do grupo experimental e do grupo controle que realizaram fisioterapia mantiveram-se estáveis ou obtiveram melhora de alguns sintomas da doença / We studied the long-term clinical response of patients with early diagnoses of HAM/TSP to treatment with methylprednisolone. The aim was to study this treatment in relation to the time of evolution and presentation of the disease and its effectiveness. The patients were followed using the scales of clinical criteria by Osame and Kurtzke, and compared with a control group of patients who did not receive this treatment type. We observed that patients in the experimental group and the control group, having been followed up with physiotherapy, either remained stable or presented improvement for some symptoms of the disease
9

"Estudo comparativo dos efeitos de um protocolo de cinesioterapia respiratória desenvolvido em dois diferentes meios, aquático e terrestre, na função respiratória de idosos" / Comparative effects of a respiratory exercise protocol developed in two different ways, aquatic and terrestrial, in the respiratory function of elderly

Ide, Maiza Ritomy 09 December 2004 (has links)
O envelhecimento populacional é uma preocupação mundial, acarretando prejuízos pulmonares. A cinesioterapia respiratória é muito utilizada, mas pouco relacionada com o meio aquático e idosos. Este estudo analisou os efeitos da cinesioterapia respiratória realizada bem dois meios - aquático e terrestre - na força muscular respiratória, flexibilidade e expansibilidade torácica de idosos. Completaram o estudo 59 sujeitos entre 60 e 65 anos, randomizados em três grupos. Dois deles realizaram exercícios respiratórios em meios aquático e terrestre. O terceiro atuou como controle. Comparando os grupos, observou-se uma melhora estatisticamente significativa da força muscular inspiratória do grupo que realizou atividades na água. As demais variáveis não sofreram alteração significativa / Aging of the population is a mundial concern. It causes damages in the pulmonary system. Respiratory exercises are too much used, but not so much related with the aquatic environment and aged. This study analised the effects of the respiratory exercise realized in two environments - aquatic and earth - in the respiratory muscle strength, thoracic mobility and flexibility in healthy aged. Completed the study 59 subjects between 60 and 65 years, randomized in three groups. Two of then realized respiratory exercises in earth and water and the third one acted as a control. Comparing the groups, there was a stastically significance improve in the inspiratory muscle strength in the water group. All of the other variables analised didn't change with the intervention
10

Influência da terapia hormonal sobre a pressão ocular de mulheres na pós-menopausa / The influence of hormonal therapy on intraocular pressure in post-menopausal women

Giampani, Adriana Silva Borges 08 April 2005 (has links)
Este estudo teve por objetivo avaliar a influência da terapia hormonal sobre a pressão ocular de mulheres na pós-menopausa. A amostra foi constituída por 58 olhos de 58 pacientes no período da pós-menopausa, com indicação de terapia hormonal, com idade entre 41 e 65 anos, que não tenham utilizado hormônio nos últimos três meses. As pacientes foram randomizadas (por sorteio) em dois grupos: terapia hormonal contínua (n=32) com comprimidos de estradiol 2 mg e acetato de noretisterona 1 mg, diário durante três meses e grupo controle placebo (n=26). O estudo foi realizado de forma cega pela investigadora principal. As pacientes foram avaliadas quanto à pressão ocular, paquimetria, ceratometria e dosagens dos hormônios sexuais pré e pós-tratamento. A média de idade foi de 54,21 anos ± 4,95, sendo 53,66 anos ± 5,60 no grupo com terapia hormonal e de 54,88 anos ± 4,01 no grupo placebo. Não houve diferença significativa entre os grupos com relação a idade (p= 0,352), índice de massa corporal (p= 0,818), pressão ocular (p=0,697), ceratometria (p > 0,05), paquimetria central (p=0,580), e dosagens dos hormônios sexuais (p>0,05) no pré-tratamento. A pressão ocular média pré-tratamento foi de 14,08 mmHg ± 1,96 no grupo terapia hormonal e de 13,81 mmHg ± 3,28 no grupo placebo. Houve redução significativa da pressão ocular média entre o pré e o pós-tratamento (p=0,0009) no grupo terapia hormonal e redução não significativa no grupo placebo (p=0,108). Na avaliação entre os grupos, não houve diferença estatística nos valores de pressão ocular média no pós-tratamento. Na avaliação entre os grupos, não houve diferença estatisticamente significativa para os valores de paquimetria e ceratometria. O grupo com terapia hormonal apresentou aumento significativo dos níveis hormonais de estradiol e redução significativa nas dosagens hormonais médias de LH e FSH no pós-tratamento com 30, 60 e 90 dias (p=0,000). As dosagens hormonais no grupo placebo não apresentaram variação estatisticamente significante. No grupo terapia hormonal, houve correlação diretamente proporcional entre as pressões oculares médias e níveis hormonais de LH e FSH, e correlação inversamente proporcional com níveis hormonais de estradiol. Em resumo, houve redução da pressão ocular média no grupo terapia hormonal entre o pré e o pós-tratamento e os níveis pressóricos neste grupo se correlacionaram com os níveis hormonais de LH, FSH e estradiol / This trial aimed to assess the influence of hormonal therapy on intraocular pressure in post-menopausal women. The sample had 58 eyes of 58 patients during menopause period, indicated for hormonal therapy, they were between the age of 41 and 65 years, who have not taken hormone in the past three months. Patients were randomized (raffle) in two groups: continuous hormonal therapy (n=32) with 2 mg of estradiol and 1 mg daily of norethisterone acetate for three months and controlled placebo group (n=26). It was a blind study carried out by the main investigator. Patients were assessed regarding ocular pressure, pachymetry, keratometry and sex hormone\'s dosages, pre and post treatment. The average was 54.21 years old ± 4.95, where 53.66 years old ± 5.60 in the group with hormonal therapy and 54.88 years old ± 4.01 in the placebo group. There was no significant difference between the groups regarding age (p= 0.352), body mass index (p= 0.818), ocular pressure (p=0.697), keratometry (p > 0.05), central pachymetry (p=0.580), and sex hormone dosages (p>0.05) during pre treatment. The average pre treatment pressure was 14.08 mmHg ± 1.96 in the hormonal therapy group and 13.81 mmHg ± 3.28 in the placebo group. There was a significant reduction in the average ocular pressure between the pre and post treatment (p=0.0009) in the hormonal therapy group and not a significant reduction in the placebo group, (p=0.108). There was no statistically difference between the groups in the average ocular pressure values after treatment. There were no statistically significant differences between the two groups in the values of pachymetry and keratometry. The hormonal therapy group showed a significant increase in estradiol hormonal levels and a significant reduction in the average hormonal dosages of LH e FSH in the post treatment after 30, 60 and 90 days (p=0.000). The hormonal dosages in the placebo group no showed significant changed. In the hormonal group, there was a direct and proportional relation between the average ocular pressure and LH and FSH hormonal levels and a proportional contrariwise correlation with estradiol hormonal levels. In summary, there was a reduction in the ocular pressure average in the hormonal therapy group between the pre and post treatment and the pressure levels in this group were correlated with the hormonal levels of LH, FSH and estradiol

Page generated in 0.5011 seconds