• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 36
  • 1
  • 1
  • Tagged with
  • 38
  • 38
  • 14
  • 14
  • 10
  • 10
  • 8
  • 8
  • 8
  • 7
  • 6
  • 6
  • 6
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Avaliação in vitro da morfologia e da capacidade de paralisação de lesões incipientes de cárie artificialmente induzidas em dentes decíduos após irradiação com Laser de Er:YAG / In vitro morphological assessment and inhibition of artificial incipient caries lesions after Er:YAG laser irradiation on primary teeth

Adriana Yuri Tashima 29 May 2006 (has links)
O objetivo deste estudo in vitro foi avaliar a morfologia e a paralisação da progressão de lesões de cárie artificiais em esmalte após irradiação da superfície com laser de Er:YAG (KaVo Key II). A amostra (120 blocos de esmalte de dentes decíduos), submetida à ciclagem de pH durante 7 dias, foi divida aleatoriamente entre as fases experimentais. Na fase morfológica os espécimes receberam os seguintes tratamentos: controle (C), laser focado (LC), laser desfocado 3mm (L3), laser desfocado 6mm (L6), e foram preparados para microscopia eletrônica de varredura. Para avaliação da efetividade do laser os espécimes foram divididos entre 9 grupos experimentais: controle negativo (CN), controle positivo (CP), laser focado (LC), laser desfocado 3mm (L3), laser desfocado 6mm (L6), aplicação tópica de flúor (F), LC mais flúor (LCF), L3 mais flúor (L3F) e L6 mais flúor (L6F). Os grupos foram submetidos a novo desafio cariogênico (exceto grupo CN) seguido de preparo para microscopia de luz polarizada. Os dados obtidos foram analisados usando os testes estatísticos ANOVA e LSD. Imagens com lupa estereoscópica também foram realizadas e o resultado submetido aos testes estatísticos Qui-quadrado, Exato de Fisher e teste de concordância. A análise visual e morfológica mostrou ablação superficial da lesão de mancha branca irradiada no grupo LC, aumento de porosidade foi visualizado no grupo L3 assim como ausência de alteração morfológica no grupo L6. Os resultados da microscopia de luz polarizada mostraram que a irradiação do laser mais flúor impediu a progressão da cárie, nos grupos LCF, L3F e L6F e reduziu o corpo da lesão no grupo L6F. Pode-se concluir que a associação entre o laser de Er:YAG desfocado 6mm mais aplicação de flúor diminuiu a profundidade da lesão incipiente de cárie sem ocasionar alteração morfológica e que os demais grupos em que a associação entre laser e flúor estava presente foram efetivos na paralisação das lesões. / The aim of this in vitro study was to evaluate the morphological effects of Er:YAG laser (KaVo Key II) irradiation on artificial enamel caries lesions and its ability to arrest the progression of these lesions. The sample (120 enamel blocks from primary teeth) was previously submitted to pH-cycling and then randomly divided into the groups. In the morphological analysis, the specimens were subdivided into 4 groups: control (C), focused laser (LC), defocused laser 3mm (L3), defocused laser 6mm (L6) and then prepared for scanning electron microscopy. To evaluate the effectiveness of the laser on incipient caries lesions, the specimens were divided into 9 groups: negative control (NC), positive control (PC), focused laser (LC), defocused laser 3mm (L3), defocused laser 6mm (L6), topical fluoride application (F), LC and fluoride (LCF), L3 and fluoride (L3F) and L6 and fluoride (L6F). All groups were submitted once again to ph cycling (except NC) and prepared for polarized light microscopy. ANOVA and LSD statistical tests were used. Images were also observed under stereoscopic loupe and were submitted to Chi-square test, Fishers´ exact test and reproducibility assessment. Visual and morphological evaluations showed that superficial ablation was present on the artificial white spot caries lesions in group LC, porosity increase in group L3 and no morphological alteration in group L6. Results under polarized light microscopy showed that laser irradiation and fluoride was able to arrest the caries progression in groups LCF, L3F and L6F and reduce the lesion´s depth in L6F. In conclusion, it was detected that the association of Er:YAG defocused laser 6mm irradiation and fluoride was able to reduce the depth of the artificial incipient caries lesions without producing any morphological alteration and that the association of laser and fluoride was effective in arresting incipient caries lesions.
32

Avaliação in vitro da remoção da camada residual (smear layer) de canais radiculares achatados instrumentados com quatro diferentes sistemas rotatórios com e sem associação de ultra-som e laser ER:YAG / Evaluation of smear layer removal of flatted canals after rotary instrumentation with four diferent NiTi instruments and association with Laser Er:YAG and ultrasonic

Alexandre Capelli 13 March 2008 (has links)
Estudou-se, por meio da microscopia eletrônica de varredura, a remoção da \"smear layer\" dos canais radiculares preparados com sistemas rotatórios com e sem \"radial land\". Após a preparação, as paredes dos canais radiculares foram submetidas aos tratamentos com ultra-som, aplicação do agente quelante EDTA a 15% e do laser Er:YAG. Noventa e seis incisivos inferiores humanos foram selecionados e divididos aleatoriamente em quatro grupos distintos, preparados com técnica rotatória Free Tip (Pecora et al, 2002) com instrumentos de níquel-titânio, 0,5 mm aquém do ápice anatômico, variando-se apenas o tratamento final das paredes do canal radicular. No grupo 1 utilizou-se o hipoclorito de sódio a 2,5% durante a instrumentação; no grupo 2 realizou-se irrigação com hipoclorito de sódio a 2,5% durante a instrumentação, recebendo posteriormente irradiação com laser Er:YAG (KaVo Key Laser II), com o auxílio de uma fibra óptica 30/28 de 285 &micro;m de diâmetro, gerando uma energia total de 42 J, freqüência de 15 Hz e potencia de 250mJ input (140mJ output). A cinemática utilizada na irradiação foi de movimento helicoidal de tração da fibra óptica, de apical para cervical, durante 10 segundos, sendo repetida quatro vezes; no grupo 3 utilizou-se a solução de hipoclorito de sódio a 2,5% ativada pelo ultra-som (MiniPiezon, EMS, Suíça); no grupo 4 utilizou-se a solução de hipoclorito de sódio a 2,5% e irrigação final com EDTA a 17%. Os espécimes foram preparados para microscopia eletrônica de varredura, e as fotomicrografias obtidas dos terços médio e apical submetidas a avaliação qualitativa por três observadores previamente calibrados, que atribuíam escores as imagens. A análise estatística revelou que a presença ou ausência da superfície radial de apoio (radial land) não interferiu na limpeza das paredes dos canais radiculares. Com relação ao tratamento final, o EDTA a 15% foi capaz de eliminar a \"smear layer\" com maior eficácia, sendo seguido pelo ultra-som e finalmente o laser Er:YAG. Houve diferença estatística significante entre os terços médio e apical dos canais radiculares. / This study evaluated, in vitro, smear layer removal in apical and middle root thirds after instrumentation with four different rotary Ni-Ti instruments and the use of Er:YAG laser, ultrasonic or EDTA. Nineth six mandibular incisors root canals were instrumented with Free Tip Technique, and irrigated with 10 ml of sodium hypochlorite. In Group 1, 24 teeth were instrumented and irrigated only with 10 ml of 2.5 % sodium hypochlorite. Group 24, instrumented as group 1 and irradiated laser Er:YAG in the following parameters: 30/28 fiber optic tip, 42 J, 15Hz and 250mJ input (140mJ output), with the tip activated at the apex and removed to the canal entrance in a helicoidal moviment. Group 3, instrumented as in group 1 and associated with ultrasonic. Group 4, instrumented as in group 1 and associated with with 15% EDTA. Electronic Microscope images were evaluated showed that group 4 had significantly less smear layer (p<0,05) than the group 1 and 2, with group 3 in intermediated position. We conclude that sodium hypochlorite associated with 15% EDTA lead to root canals with less smear layer. The middle third present less smear layer than apical third.
33

Avaliação dos efeitos do laser de Er,Cr:YSGG sobre superfícies radiculares expostas no tratamento da hipersensibilidade dentinária cervical. Estudo in vitro e in vivo / Desensitizing effects of Er:YAG and Er,Cr:YSGG lasers on dentin hypersensitivity. An in vitro and in vivo study

Ana Cecilia Corrêa Aranha 03 August 2005 (has links)
O objetivo deste estudo foi o de avaliar os efeitos da irradiação laser de Er,Cr:YSGG em superfícies dentinárias no tratamento da hipersensibilidade dentinária cervical, em busca de um protocolo para ser aplicado clinicamente. Para o teste de permeabilidade, foram preparados 144 pré-molares, as coroas seccionadas e as raízes impermeabilizadas. Duas áreas de irradiação antagônicas foram delimitadas e livres da impermeabilização (controle e experimental). A seguir, os dentes foram subdivididos em dois sub-grupos, diferindo o condicionamento da superfície irradiada (EDTA 24% e ácido fosfórico 35%) e em grupos diferindo o protocolo:G1)Er:YAG, 60mJ/2Hz; G2)0,25W; G3)0,5W; G4)0,75W; G5)1W, G6)1,25W; G7)1,50W; G8)1,75W G9)2W. Após as irradiações, os espécimes foram imersos em azul de metileno 2% por 4 horas, e incluídos em resina epóxica para a realização dos cortes longitudinais. Estes tiveram suas imagens trabalhadas em computador para mensuração do nível de infiltração. Os dados foram submetidos à análise estatística. O Sub-grupo 1, condicionado com EDTA, apresentou diferenças entre os grupos sendo que as amostras irradiadas com Er:YAG demonstraram menor infiltração, diferindo estatisticamente dos grupos 3, 6 e 9. Os resultados do sub-grupo 2 mostraram que as médias das amostras irradiadas com Er:YAG tenderam a zero entretanto, não houve diferença entre os grupos. Na Fase B, fragmentos de dentina foram obtidos da região cervical de dentes humanos, preparados para análise em microscopia eletrônica de varredura. Morfologicamente, observou-se oclusão parcial dos túbulos dentinários após irradiação com Er:YAG e Er,Cr:YSGG nas condições de 0,25W e 0,50W. A partir de 0.75W, foi observado abertura dos túbulos e à medida que as energias aumentaram, foram observadas carbonização e fendas. De posse dos resultados dos trabalhos in vitro, foram selecionados os parâmetros para a aplicação e o acompanhamento clínico de 1 mês: G1)controle (placebo); G2)Er:YAG; G3)Er,Cr:YSGG 0,25W e G4)Er,Cr:YSGG 0,75W. Após a triagem, foram selecionados voluntários de acordo com critérios de exclusão e inclusão. O nível de sensibilidade de cada voluntário foi avaliado através da escala visual analógica de dor (VAS) com auxílio do ar da seringa tríplice 1 semana antes (Pré-1), 5 minutos anterior ao tratamento (Pré-2), após 5 minutos (Pós-1), 1 semana (Pós-2) e 1 mês após o tratamento (Pós-3). Os dados foram coletados e submetidos à análise estatística separadamente para os dois estímulos realizados: spray de ar e sonda exploradora. Tanto para o estímulo ar quanto para o estímulo sonda, não foram observadas diferenças estatisticamente significantes nas escalas Pré-1 e Pré-2, concluindo que os pacientes estavam padronizados e não houve efeito da profilaxia nos níveis de dor. Ao estímulo do spray de ar, nota-se uma redução nos níveis de dor na escala Pós-1, porém há uma estabilidade dos valores das escalas seguintes. O grupo 2 (Er:YAG) apresentou o menor nível de dor quando comparado aos outros grupos. Ao estímulo mecânico foi observado que o grupo 4 (Er,Cr:YSGG 0,50W) demonstrou o decréscimo de dor mais acentuado imediatamente após o tratamento, porém ao final do estudo, apresentou os maiores níveis de dor. Os grupos 1, 2 e 3 apresentam redução de dor, porém estatisticamente diferentes do grupo 4. Com base nos resultados apresentados e dentro dos limites e parâmetros estudados, pode-se concluir que nenhuma condição foi capaz de eliminar completamente a microinfiltração e diminuir a permeabilidade dentinária; porém o laser de Er:YAG e o laser de Er,Cr:YSGG 0,25W apresentaram resultados satisfatórios nos três estudos realizados. / The aim of the present study was to determine the correct parameters of the Er,Cr:YSGG laser in the treatment of cervical dentin hypersensitivity. This work was presented in 3 different stages. In the first one, it was evaluated the decrease in dentin permeability of dentinal tubules after Er,Cr:YSGG laser irradiation in radicular surfaces. Ninety premolars were prepared with its crows sectioned, and the roots completely impermeabilized. Two antagonist areas of irradiation were determined as control and experimental. Each surface was conditioned with EDTA 24% (sub-group1) and phosphoric acid 35% (sub-group2) and the selected parameters were: 1)Er:YAG, 60mJ, 2Hz, 4 irradiations of 20sec each, defocused mode; and groups 2 to 9 received irradiation with Er,Cr:YSGG laser, 20Hz, Z6 tip, 600µm diameter, defocus mode, 0% of air and water: 2)Er,Cr:YSGG 0,25W; 3) 0,5W; 4) 0,75W; 5) 1,0W; 6) 1,25W, 7) 1,50W, 8) 2W; 9) 2 W. After irradiation, samples were immersed in a solution of methylene blue for 4 hours, washed for 5 min and included in epoxy resin to allow longitudinal cuts. The images were digitalized and computed worked. Data was statistically analyzed. Although the samples irradiated with Er:YAG showed less microleakage, the sub-group 1 showed differences between the groups, statistically different from groups 3, 6 e 9. The results of the sub-group 2 showed that the mean values of the Er:YAG samples had a tendency to be negative, however, no differences were detected between the groups. In the second stage, cuts from the cervical area were obtained and prepared for scanning electron microscopy to evaluate the superficial morphology. It was observed the partial closure of dentinal tubules after the irradiation with Er:YAG and Er,Cr:YSGG laser in the 0.25 and 0.50W protocols. From the 0.75W until 2W, it was observed the dentinal tubules opened as the energy densities raised. With the results of the in vitro studies, the parameters were selected: G1)control; G2)Er:YAG; G3)Er,Cr:YSGG 0,25W e G4)Er,Cr:YSGG 0,75W. Thirty subjects, who met the entry criteria, were admitted into the study. The assessment method used to quantify sensitivity was the cold air syringe, recorded by the visual analogue scale (VAS), prior to treatment as baseline (Pre-1), immediately before (Pre-2) and immediately after (Post-1) the topical treatment, after 1 week (Post-2) and after 1 month (Post-3). Teeth were assigned to the 4 groups. After the follow-up, data was collected and submitted to statistical analysis for both kinds of stimulus: evaporative (air) and mechanical (probe). For both air and probe it was not observed differences among the Pre-1 and Pre-2 moments, for what it can be concluded that patients were standardized. Analyzing the evaporative stimulus, it can be observed the reduction in the pain level immediately after the treatment; however there was stability in the next values. Group 2 (Er:YAG) showed the least level of pain. Throughout the mechanical stimulus, it was observed that group 4 (Er,Cr:YSGG 0,50W) showed the most pronounced decrease of pain immediately after treatment, however, at the end of the study, the levels of pain increased. Groups 1, 2 e 3 showed reduction of pain, statistically different from the group 4. Based on the results and within the limits of this study, it can be concluded that none of the parameters and lasers studied were capable of eliminate the microleakage and decrease the dentin permeability, however, the Er:YAG and Er,Cr:YSGG 0,25W lasers showed satisfactory results in the three studies performed.
34

Avaliação in vitro da morfologia e da resistência de união de adesivos à dentina humana hígida ou submetida à ciclagem erosiva e irradiada com os lasers de Er:YAG e Er,Cr:YSGG / In vitro evaluation of the morphology and the bond strength of adhesives to sound and artificially eroded human dentin irradiated with Er:YAG and Er,Cr:YSGG laser

Thaysa Monteiro Ramos 04 July 2012 (has links)
A erosão dental provoca alterações histológicas complexas na dentina e, apesar do aumento da ocorrência desta patologia na última década, a literatura apresenta poucos estudos sobre a adesão na dentina erodida. Com o aprimoramento da tecnologia e o conhecimento de que os lasers de érbio apresentam grande afinidade pela água e hidroxiapatita, sua utilização tem sido considerada um método alternativo para tratamento da superfície dentinária antes dos procedimentos adesivos. Assim, o objetivo deste trabalho in vitro foi avaliar o efeito de diferentes tratamentos de superfície (ponta diamantada, laser de Er:YAG 2,94 m, 60 mJ, 2 Hz, 0,2 W, 19,3 J/cm2 - e laser de Er,Cr:YSGG 2,78 m, 50 mJ, 30 Hz, 1,5 W, 4,5 J/cm2), prévios ao tratamento restaurador, tanto na dentina humana hígida quanto na dentina artificialmente erodida. Metade das amostras foi submetida à ciclagem erosiva, a qual foi realizada durante 5 dias por meio da imersão em solução de ácido cítrico 0,05 M (pH 2,3, 10 minutos, 6x/dia) e solução supersaturada (pH 7,0, 60 minutos entre os ataques ácidos). Na fase experimental 1, 32 fragmentos de dentina foram divididos aleatoriamente em 8 grupos (n = 4) e com o auxílio da Microscopia Eletrônica de Varredura (MEV), realizou-se a análise da morfologia da superfície da dentina hígida e da submetida à ciclagem erosiva, após os diferentes tratamentos de superfície. Na fase experimental 2, 192 terceiros molares humanos foram divididos aleatoriamente em 2 grupos (dentina hígida e dentina submetida à ciclagem erosiva) e 8 subgrupos (n = 12) para avaliação da resistência de união entre as superfícies tratadas e 2 sistemas adesivos (01 autocondicionante e 01 com condicionamento ácido prévio), por meio do ensaio de microtração e da análise do padrão de fratura. Para o ensaio de microtração, blocos de resina composta microhíbrida foram confeccionados na superfície de dentina e, após armazenados em água destilada-deionizada por 24h (37oC), palitos foram obtidos para serem tracionados na máquina de ensaio universal (0,5mm/min). A análise do padrão de fratura realizada em microscópio ótico (40x) e as avaliações das eletromicrografias foram feitas de forma descritiva. Os valores obtidos de resistência de união(MPa) foram submetidos aos testes de ANOVA (dois fatores) e de comparações múltiplas de Tukey (p<0,05). A análise morfológica de superfície mostrou alterações significativas da dentina hígida e da dentina artificialmente erodida, submetidas aos diferentes tratamentos de superfície. Quanto à resistência de união, na dentina hígida, o grupo controle, tanto do sistema autocondicionante (54,69 ± 7,80 MPa) quanto do condicionamento ácido total (47,36 ± 9,35 MPa), apresentou valores significativamente maiores que os outros grupos, sendo, porém, diferentes entre si. Na dentina erodida, a maior resistência de união foi alcançada com o grupo tratado com o laser de Er,Cr:YSGG associado ao adesivo autocondicionante (28,26 ± 9,22 MPa), o qual foi significativamente diferente de todos demais grupos. Com base nos parâmetros de irradiação utilizados neste estudo, pode-se concluir que em dentina hígida, os tratamentos de superfície com os lasers de Er:YAG e Er,Cr:YSGG apresentaram resultados de adesão inferiores, mas satisfatórios, em relação ao grupo controle. Já em substrato dentinário erodido, a irradiação com laser de Er,Cr:YSGG, associada ao uso de sistema adesivo autocondicionante, promoveu efeito positivo para a adesão à resina composta. / Dental erosion can cause complex histological changes in dentin and, despite the increase in its incidence during the last decade, limited information is available regarding adhesion to eroded dentin. With improvements in technology and due to the fact that the erbium lasers have high affinity to water and hydroxyapatite, the use of laser can consist on an alternative for the treatment of dentin surface before adhesive procedures. The aim of this in vitro study was to evaluate the effect of different surface treatments (diamond bur, Er:YAG laser 2.94 m, 60 mJ, 2 Hz, 0.2 W, 19.3 J/cm2 - and Er,Cr:YSGG laser 2.78 m, 50 mJ, 30 Hz, 1.5 W, 4.5 J/cm2) prior to restorative treatment, in sound and artificially eroded human dentin. Half of the samples was submitted to the erosive cycling, which was performed by immersion in 0.05 M citric acid (pH 2.3, 10 min, 6x/day) and in supersaturated solution (pH 7.0, 1h, between acid attacks), during 5 days. In phase 1, 32 dentin fragments were randomly divided into 8 groups (n = 4). The analysis of surface morphology of both sound and eroded dentin was performed by Scanning Electron Microscopy (SEM), after the different surface treatments. In phase 2, 192 human third molars were randomly divided into 2 groups (sound and eroded dentin) and 8 subgroups (n=12) to evaluate the bond strength between the treated surfaces and composite resin, with two adhesive systems (self-etching and total-etching) by means of the microtensile bond strength (TBS) test and fracture pattern analysis. For the microtensile bond strength test, blocks of composite resin were bonded to the samples and, after 24 h-storage in distilled/deionized water (37°C), stick-shapped samples were obtained and submitted to TBS test in a universal testing machine (0.5 mm/min). The fracture pattern was performed with an optical microscopy (40x) and the evaluations of the electromicrographs were made under a descriptive mode. The bond strength values (MPa) were analyzed by two-way ANOVA and Tukey tests ( = 0.05). In sound dentin, for the control group, both self-etching (54.69 ± 7.8 MPa) and total-etching adhesive system (47.36 ± 9.3 MPa) showed significantly higher values than all other groups (p<0.05), even though they differ from each other. However, in eroded dentin groups, the self-etching on the samples treated with the Er,Cr:YSGG laser presented the highest mean (28.3 ± 9.2 MPa), which was statistically significant higher than all the other treatments (p<0.05). Based on the irradiation parameters considered for this study, it can be concluded that in healthy dentin, the surface treatment with Er:YAG and Er,Cr:YSGG irradiation showed bonding values lower than the control group, but they presented satisfactory results. However, in eroded dentin, the use of Er,Cr:YSGG laser, associated with the self-etching adhesive system, promoted positive effect on adhesion to composite resin.
35

Avaliação do tratamento de superfície com laser de Er:YAG de pulso super curto sobre a adesão em dentina hígida e afetada por cárie: estudo longitudinal / Evaluation of Super Short Pulse Er:YAG laser treatment on adhesion of sound and caries affected dentin: longitudinal study

Azevedo, Cynthia Soares de 11 December 2015 (has links)
Este estudo longitudinal investigou a influência de tratamentos de superfície com o laser de Er:YAG com 50?s de largura de pulso sobre a adesão de dois sistemas adesivos autocondicionantes (SA) em dentina hígida (DH) e dentina afetada por cárie (DAC) através dos teste de resistência de união (RU) de microcisalhamento (?SBS), teste de ultramicrodureza da camada de adesivo (NdA) e da camada híbrida (NdCH), além de análise da interface adesiva com microscopia eletrônica de varredura (MEV). A análise qualitativa dos tratamentos de superfície realizados foi executada através de MEV e microscopia eletrônica de transmissão (MET). A dentina oclusal planificada de 215 molares humanos foi protegida com verniz ácido resistente, exceto em janela de 4x5mm para produção de DAC artificial após 7 dias de desafio cariogênico com biofilme de S. mutans, permitindo dados pareados por substrato. Os espécimes foram divididos nos grupos experimentais de acordo com: tratamento de superfície [controle-sem tratamento-(G1); Laser 80-80mJ, 2 Hz, 12.58J/cm2-(G2); Laser 50-50mJ, 10 Hz, 9.4J/cm2-(G3)]; sistema adesivo [Clearfil SE Bond(CF) e Single Bond Universal(SB)]; substrato [DH(h) ou DAC(a)] e tempo de armazenamento em saliva artificial [24 horas (24) ou 1 ano (1)], compondo 24 grupos experimentais: CFG1h24; CFG1h1; CFG1a24; CFG1a1; CFG2h24; CFG2h1; CFG2a24; CFG2a1; CFG3h24; CFG3h1; CFG3a24; CFG3a1; SBG1h24; SBG1h1; SBG1a24; SBG1a1; SBG2h24; SBG2h1; SBG2a24; SBG2a1; SBG3h24; SBG3h1; SBG3a24; SBG3a1. Nos grupos tratados com laser a largura temporal de pulso foi ajustada em 50?s. A resina composta Z350XT foi utilizada para a confecção dos corpos de prova. Os sistemas adesivos foram aplicados de acordo com as instruções do fabricante. As análises de MEV e MET de superfície avaliaram somente o efeito dos tratamentos em ambos os substratos testados. Os valores de RU e de nanodureza foram analisados através do teste de ANOVA (três fatores) e do teste de comparações múltiplas de Tukey (?=0,05). Para o teste de ?SBS, para ambos os SA, e todos tratamentos de superfície, a DAC apresentou valores de RU menores comparados à DH; a influência do armazenamento em saliva artificial foi substrato dependente: corpos de prova obtidos com DAC apresentaram queda nos valores de RU após 1 ano de armazenamento, enquanto nenhuma diferença entre os grupos experimentais foi observada em dentina hígida. NdA revelou que apenas os corpos de prova construídos com CF apresentaram redução dos valores após 1 ano. A NdCH obtida com CF e SB, resultou em menores valores em DAC comparada à DH, após 1 ano de armazenamento ambos os substratos apresentaram redução da NdCH, para todos tratamentos de superfície. A MEV revelou que todas as interfaces adesivas, especialmente aquelas obtidas em DAC, sofreram degradação intensa após 1 ano. Os tratamentos com Laser 80 e Laser 50 promovem alteração superficial característica de ablação em DAC e DH, conforme observado em MEV de superfície, e alterações de fibrilas colágenas observadas em MET. Independentemente dos SA, a adesão e nanodureza em DAC é menor que em DH. Todas as interfaces adesivas obtidas foram sensíveis ao armazenamento em saliva artificial por 1 ano. A adesão não foi influenciada pelo tratamento com o laser Er:YAG com 50?s de largura de pulso. / This longitudinal study investigated the influence of super short pulse Er:YAG laser treatment on microshear bond strength (?SBS), adhesive and hybrid layer nanohardness test and qualitative interface scanning electron microscopy (SEM) of two self-etch adhesive systems to sound (SD) and caries-affected like dentin (CAD). Additionally, qualitative investigation of surface treatments by SEM and transmission electron microscopy (TEM) were performed. CAD lesions (4x5mm) were produced by 7 days S. mutans biofilm cariogenic challenge in 215 human ground flat human dentin specimens, enabling paired data by substrate. Specimen were divided in groups according to surface treatment [control-no treatment-(G1); Laser 80-80mJ, 2Hz, 12.58J/cm2-(G2); Laser 50-50mJ, 10Hz, 9.4J/cm2-(G3)]; self-etching adhesive system [Clearfil SE Bond(CF) and Single Bond Universal(SB)]; substrate [SD(h) or CAD(a)] and artificial saliva storage [24 hours(24) or 1 year(1)]: CFG1h24; CFG1h1; CFG1a24; CFG1a1; CFG2h24; CFG2h1; CFG2a24; CFG2a1; CFG3h24; CFG3h1; CFG3a24; CFG3a1; SBG1h24; SBG1h1; SBG1a24; SBG1a1; SBG2h24; SBG2h1; SBG2a24; SBG2a1; SBG3h24; SBG3h1; SBG3a24; SBG3a1. Pulse duration was set in 50?s for laser groups. ?SBS, nanohardness and interface SEM specimen preparation was constructed with Z350XT composite resin. Adhesive systems were applied according to manufacturer\'s instructions. Surface SEM and TEM specimen only evaluated treatment effects on distinct substrates. The ?SBS and nanohardness means were analysed using three-way ANOVA and Tukey´s multiples comparisons test (?=0.05). For ?SBS test, for both adhesive systems, and all surface treatments, CAD revealed lower ?SBS values compared to SD; the influence of artificial saliva storage was substrate dependent. CAD specimens resulted in lower ?SBS values after 1 year, while no difference among experimental groups was observed in SD. The adhesive layer (AL) nanohardness statistical evaluation revealed that only CF specimens decreased the AL nanohardness after 1 year of storage. The hybrid layer (HL) produced with CF and SB, resulted in lower nanohardness values for CAD than SD, which reduces after 1 year storage, for all surface treatments. Interface SEM analysis revealed that all adhesive interfaces, especially those in CAD, have experienced degradation after 1 year of storage. Laser 80 and Laser 50 promotes surface ablation characteristics in CAD and SD, as noted in surface SEM and collagen fibrils alterations observed in TEM. Despite of adhesive systems, bonding and nanohardness to CAD is lower than to SD. All tested adhesive interfaces were sensitive to saliva storage. Surface treatment with 50?s Er:YAG laser did not influence on bonding.
36

Análise morfológica e da resistência de união da superfície dentinária irradiada com os lasers de Er:YAG e Er,Cr:YSGG / Morphological analysis and micro-tensile bond strength of dentin surface irradiated with Er:YAG and Er,Cr:YSGG lasers

Moretto, Simone Gonçalves 03 March 2009 (has links)
Avanços na tecnologia introduziram o laser como um grande aliado na remoção seletiva do tecido cariado. Entretanto, o efeito dos lasers e seus diferentes parâmetros nos tecidos duros dentais e fibrilas colágenas não foi completamente estudado. O objetivo deste estudo foi avaliar os efeitos da irradiação com os lasers de Er:YAG e Er,Cr:YSGG na morfologia e na resistência de união da dentina irradiada à resina composta. Sessenta e quatro hemi-discos de dentina obtidos de terceiros molares humanos foram aleatoriamente divididos em 9 grupos (n=7): G1 Controle (não irradiado); G2 Laser de Er:YAG 250 mJ, 4 Hz; G3 Laser de Er:YAG 200 mJ, 4 Hz; G4 Laser de Er:YAG 180 mJ, 10 Hz; G5 Laser de Er:YAG 160 mJ, 10 Hz; G6 - Laser de Er,Cr:YSGG 2W, 20 Hz; G7 - Laser de Er,Cr:YSGG 2,5W, 20 Hz; G8 - Laser de Er,Cr:YSGG 3W, 20 Hz; G9 - Laser de Er,Cr:YSGG 4W, 20 Hz. Destes, vinte e sete amostras (n=3) foram processadas e destinadas à avaliação em Microscopia Eletrônica de Varredura (MEV) para análise morfológica de superfície e em corte transversal da dentina irradiada. Nove fragmentos (n=1) foram submetidos à Microscopia Eletrônica de Transmissão (MET) e vinte e sete (n=3) foram restaurados para análise da interface adesiva. Para o teste de resistência de união, 45 superfícies dentinárias planificadas foram restauradas e, após 24 horas de armazenamento em água, foram submetidas ao teste de microtração. O teste de ANOVA (=5%) foi realizado e verificou-se que o G1 apresentou os maiores valores de resistência de união quando comparado aos demais grupos experimentais. Não houve diferença estatisticamente significativa entre os grupos irradiados, e a análise morfológica revelou para estes grupos uma superfície irregular, com aparência escamosa, sem smear layer e com os túbulos dentinários abertos. Nos cortes transversais foi possível observar que esses efeitos se estendem à subsuperfície dentinária e resultam na formação de um padrão modificado dos tags durante o processo de hibridização. Os resultados deste estudo in vitro sugerem que a irradiação com os lasers de Er:YAG e Er,Cr:YSGG promovem um padrão morfológico específico da superfície dentinária, os quais podem interferir negativamente nos valores de resistência de união à resina composta. / Improvements on technology have introduced the laser as a great ally in the selected removal of dental caries. However, the different laser parameters and their effects on dental hard tissues and collagen fibrils have not yet been completely studied. The aim of the present study was to evaluate the effect of Er:YAG and Er,Cr:YSGG laser irradiation on dentin morphology and on microtensile bond strength of resin composite to the irradiated dentin. Sixty-four dentin hemi-disks obtained from sound human third molars were randomly divided into 9 groups (n=7): G1 Control, G2 Er:YAG Laser 250 mJ, 4 Hz; G3 Er:YAG Laser 200 mJ, 4 Hz; G4 Er:YAG Laser 180 mJ, 10 Hz; G5 Er:YAG Laser 160 mJ, 10 Hz; G6 - Er,Cr:YSGG Laser 2W, 20 Hz; G7 - Er,Cr:YSGG Laser 2,5W, 20 Hz; G8 - Er,Cr:YSGG Laser 3W, 20 Hz; G9 - Er,Cr:YSGG Laser 4W, 20 Hz. Twenty seven specimens (n=3) were processed for Scanning Electron Microscopy (SEM) for surface and cross-sectional morphological analysis. Nine specimens (n=1) were processed for Transmission Electron Microscopy (TEM) and twenty seven (n=3) were restored to evaluate the adhesive interface. For the microtensile bond strength (^TBS) test, 45 flat occlusal dentin surfaces were restored and after storage in water for 24h, were submitted to ^TBS test. ANOVA (=5%) showed that G1 (control group) presented the highest ^TBS values when compared with the irradiated groups, which did not differ from each other. SEM analysis showed an irregular scaly surface, free of smear layer and with open dentinal tubules. The cross-sectional dentin micrographs showed that the effects of laser extended to the dentin subsurface resulting in a pattern of tags modified in the hibridization process. The findings of this in vitro study showed that both Er:YAG and Er,Cr:YSGG laser irradiation resulted in a specific morphological pattern of dentin that negatively affects the bond strength to resin composite to such dentin.
37

Análise morfológica e da resistência de união da superfície dentinária irradiada com os lasers de Er:YAG e Er,Cr:YSGG / Morphological analysis and micro-tensile bond strength of dentin surface irradiated with Er:YAG and Er,Cr:YSGG lasers

Simone Gonçalves Moretto 03 March 2009 (has links)
Avanços na tecnologia introduziram o laser como um grande aliado na remoção seletiva do tecido cariado. Entretanto, o efeito dos lasers e seus diferentes parâmetros nos tecidos duros dentais e fibrilas colágenas não foi completamente estudado. O objetivo deste estudo foi avaliar os efeitos da irradiação com os lasers de Er:YAG e Er,Cr:YSGG na morfologia e na resistência de união da dentina irradiada à resina composta. Sessenta e quatro hemi-discos de dentina obtidos de terceiros molares humanos foram aleatoriamente divididos em 9 grupos (n=7): G1 Controle (não irradiado); G2 Laser de Er:YAG 250 mJ, 4 Hz; G3 Laser de Er:YAG 200 mJ, 4 Hz; G4 Laser de Er:YAG 180 mJ, 10 Hz; G5 Laser de Er:YAG 160 mJ, 10 Hz; G6 - Laser de Er,Cr:YSGG 2W, 20 Hz; G7 - Laser de Er,Cr:YSGG 2,5W, 20 Hz; G8 - Laser de Er,Cr:YSGG 3W, 20 Hz; G9 - Laser de Er,Cr:YSGG 4W, 20 Hz. Destes, vinte e sete amostras (n=3) foram processadas e destinadas à avaliação em Microscopia Eletrônica de Varredura (MEV) para análise morfológica de superfície e em corte transversal da dentina irradiada. Nove fragmentos (n=1) foram submetidos à Microscopia Eletrônica de Transmissão (MET) e vinte e sete (n=3) foram restaurados para análise da interface adesiva. Para o teste de resistência de união, 45 superfícies dentinárias planificadas foram restauradas e, após 24 horas de armazenamento em água, foram submetidas ao teste de microtração. O teste de ANOVA (=5%) foi realizado e verificou-se que o G1 apresentou os maiores valores de resistência de união quando comparado aos demais grupos experimentais. Não houve diferença estatisticamente significativa entre os grupos irradiados, e a análise morfológica revelou para estes grupos uma superfície irregular, com aparência escamosa, sem smear layer e com os túbulos dentinários abertos. Nos cortes transversais foi possível observar que esses efeitos se estendem à subsuperfície dentinária e resultam na formação de um padrão modificado dos tags durante o processo de hibridização. Os resultados deste estudo in vitro sugerem que a irradiação com os lasers de Er:YAG e Er,Cr:YSGG promovem um padrão morfológico específico da superfície dentinária, os quais podem interferir negativamente nos valores de resistência de união à resina composta. / Improvements on technology have introduced the laser as a great ally in the selected removal of dental caries. However, the different laser parameters and their effects on dental hard tissues and collagen fibrils have not yet been completely studied. The aim of the present study was to evaluate the effect of Er:YAG and Er,Cr:YSGG laser irradiation on dentin morphology and on microtensile bond strength of resin composite to the irradiated dentin. Sixty-four dentin hemi-disks obtained from sound human third molars were randomly divided into 9 groups (n=7): G1 Control, G2 Er:YAG Laser 250 mJ, 4 Hz; G3 Er:YAG Laser 200 mJ, 4 Hz; G4 Er:YAG Laser 180 mJ, 10 Hz; G5 Er:YAG Laser 160 mJ, 10 Hz; G6 - Er,Cr:YSGG Laser 2W, 20 Hz; G7 - Er,Cr:YSGG Laser 2,5W, 20 Hz; G8 - Er,Cr:YSGG Laser 3W, 20 Hz; G9 - Er,Cr:YSGG Laser 4W, 20 Hz. Twenty seven specimens (n=3) were processed for Scanning Electron Microscopy (SEM) for surface and cross-sectional morphological analysis. Nine specimens (n=1) were processed for Transmission Electron Microscopy (TEM) and twenty seven (n=3) were restored to evaluate the adhesive interface. For the microtensile bond strength (^TBS) test, 45 flat occlusal dentin surfaces were restored and after storage in water for 24h, were submitted to ^TBS test. ANOVA (=5%) showed that G1 (control group) presented the highest ^TBS values when compared with the irradiated groups, which did not differ from each other. SEM analysis showed an irregular scaly surface, free of smear layer and with open dentinal tubules. The cross-sectional dentin micrographs showed that the effects of laser extended to the dentin subsurface resulting in a pattern of tags modified in the hibridization process. The findings of this in vitro study showed that both Er:YAG and Er,Cr:YSGG laser irradiation resulted in a specific morphological pattern of dentin that negatively affects the bond strength to resin composite to such dentin.
38

Avaliação do tratamento de superfície com laser de Er:YAG de pulso super curto sobre a adesão em dentina hígida e afetada por cárie: estudo longitudinal / Evaluation of Super Short Pulse Er:YAG laser treatment on adhesion of sound and caries affected dentin: longitudinal study

Cynthia Soares de Azevedo 11 December 2015 (has links)
Este estudo longitudinal investigou a influência de tratamentos de superfície com o laser de Er:YAG com 50?s de largura de pulso sobre a adesão de dois sistemas adesivos autocondicionantes (SA) em dentina hígida (DH) e dentina afetada por cárie (DAC) através dos teste de resistência de união (RU) de microcisalhamento (?SBS), teste de ultramicrodureza da camada de adesivo (NdA) e da camada híbrida (NdCH), além de análise da interface adesiva com microscopia eletrônica de varredura (MEV). A análise qualitativa dos tratamentos de superfície realizados foi executada através de MEV e microscopia eletrônica de transmissão (MET). A dentina oclusal planificada de 215 molares humanos foi protegida com verniz ácido resistente, exceto em janela de 4x5mm para produção de DAC artificial após 7 dias de desafio cariogênico com biofilme de S. mutans, permitindo dados pareados por substrato. Os espécimes foram divididos nos grupos experimentais de acordo com: tratamento de superfície [controle-sem tratamento-(G1); Laser 80-80mJ, 2 Hz, 12.58J/cm2-(G2); Laser 50-50mJ, 10 Hz, 9.4J/cm2-(G3)]; sistema adesivo [Clearfil SE Bond(CF) e Single Bond Universal(SB)]; substrato [DH(h) ou DAC(a)] e tempo de armazenamento em saliva artificial [24 horas (24) ou 1 ano (1)], compondo 24 grupos experimentais: CFG1h24; CFG1h1; CFG1a24; CFG1a1; CFG2h24; CFG2h1; CFG2a24; CFG2a1; CFG3h24; CFG3h1; CFG3a24; CFG3a1; SBG1h24; SBG1h1; SBG1a24; SBG1a1; SBG2h24; SBG2h1; SBG2a24; SBG2a1; SBG3h24; SBG3h1; SBG3a24; SBG3a1. Nos grupos tratados com laser a largura temporal de pulso foi ajustada em 50?s. A resina composta Z350XT foi utilizada para a confecção dos corpos de prova. Os sistemas adesivos foram aplicados de acordo com as instruções do fabricante. As análises de MEV e MET de superfície avaliaram somente o efeito dos tratamentos em ambos os substratos testados. Os valores de RU e de nanodureza foram analisados através do teste de ANOVA (três fatores) e do teste de comparações múltiplas de Tukey (?=0,05). Para o teste de ?SBS, para ambos os SA, e todos tratamentos de superfície, a DAC apresentou valores de RU menores comparados à DH; a influência do armazenamento em saliva artificial foi substrato dependente: corpos de prova obtidos com DAC apresentaram queda nos valores de RU após 1 ano de armazenamento, enquanto nenhuma diferença entre os grupos experimentais foi observada em dentina hígida. NdA revelou que apenas os corpos de prova construídos com CF apresentaram redução dos valores após 1 ano. A NdCH obtida com CF e SB, resultou em menores valores em DAC comparada à DH, após 1 ano de armazenamento ambos os substratos apresentaram redução da NdCH, para todos tratamentos de superfície. A MEV revelou que todas as interfaces adesivas, especialmente aquelas obtidas em DAC, sofreram degradação intensa após 1 ano. Os tratamentos com Laser 80 e Laser 50 promovem alteração superficial característica de ablação em DAC e DH, conforme observado em MEV de superfície, e alterações de fibrilas colágenas observadas em MET. Independentemente dos SA, a adesão e nanodureza em DAC é menor que em DH. Todas as interfaces adesivas obtidas foram sensíveis ao armazenamento em saliva artificial por 1 ano. A adesão não foi influenciada pelo tratamento com o laser Er:YAG com 50?s de largura de pulso. / This longitudinal study investigated the influence of super short pulse Er:YAG laser treatment on microshear bond strength (?SBS), adhesive and hybrid layer nanohardness test and qualitative interface scanning electron microscopy (SEM) of two self-etch adhesive systems to sound (SD) and caries-affected like dentin (CAD). Additionally, qualitative investigation of surface treatments by SEM and transmission electron microscopy (TEM) were performed. CAD lesions (4x5mm) were produced by 7 days S. mutans biofilm cariogenic challenge in 215 human ground flat human dentin specimens, enabling paired data by substrate. Specimen were divided in groups according to surface treatment [control-no treatment-(G1); Laser 80-80mJ, 2Hz, 12.58J/cm2-(G2); Laser 50-50mJ, 10Hz, 9.4J/cm2-(G3)]; self-etching adhesive system [Clearfil SE Bond(CF) and Single Bond Universal(SB)]; substrate [SD(h) or CAD(a)] and artificial saliva storage [24 hours(24) or 1 year(1)]: CFG1h24; CFG1h1; CFG1a24; CFG1a1; CFG2h24; CFG2h1; CFG2a24; CFG2a1; CFG3h24; CFG3h1; CFG3a24; CFG3a1; SBG1h24; SBG1h1; SBG1a24; SBG1a1; SBG2h24; SBG2h1; SBG2a24; SBG2a1; SBG3h24; SBG3h1; SBG3a24; SBG3a1. Pulse duration was set in 50?s for laser groups. ?SBS, nanohardness and interface SEM specimen preparation was constructed with Z350XT composite resin. Adhesive systems were applied according to manufacturer\'s instructions. Surface SEM and TEM specimen only evaluated treatment effects on distinct substrates. The ?SBS and nanohardness means were analysed using three-way ANOVA and Tukey´s multiples comparisons test (?=0.05). For ?SBS test, for both adhesive systems, and all surface treatments, CAD revealed lower ?SBS values compared to SD; the influence of artificial saliva storage was substrate dependent. CAD specimens resulted in lower ?SBS values after 1 year, while no difference among experimental groups was observed in SD. The adhesive layer (AL) nanohardness statistical evaluation revealed that only CF specimens decreased the AL nanohardness after 1 year of storage. The hybrid layer (HL) produced with CF and SB, resulted in lower nanohardness values for CAD than SD, which reduces after 1 year storage, for all surface treatments. Interface SEM analysis revealed that all adhesive interfaces, especially those in CAD, have experienced degradation after 1 year of storage. Laser 80 and Laser 50 promotes surface ablation characteristics in CAD and SD, as noted in surface SEM and collagen fibrils alterations observed in TEM. Despite of adhesive systems, bonding and nanohardness to CAD is lower than to SD. All tested adhesive interfaces were sensitive to saliva storage. Surface treatment with 50?s Er:YAG laser did not influence on bonding.

Page generated in 0.0678 seconds