Spelling suggestions: "subject:"esgotos – tratamento"" "subject:"esgotos – ratamento""
1 |
Avaliação da influência da operação de descarte de lodo no desempenho dos reatores UASB em estações de tratamento de esgotos no Distrito Federal / Evaluating the influence of sludge dischard over uasb reactors performance in sewage treatment plants in the Federal District, BrazilRamos, Ricardo Augusto 18 December 2008 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Civil e Ambiental, 2008. / Submitted by Diogo Trindade Fóis (diogo_fois@hotmail.com) on 2009-10-01T11:20:46Z
No. of bitstreams: 1
2008_RicardoAugustoRamos.pdf: 3111074 bytes, checksum: 5b6cf5162e1fff5cee3dc0724ece630b (MD5) / Approved for entry into archive by Marília Freitas(marilia@bce.unb.br) on 2010-02-10T00:36:20Z (GMT) No. of bitstreams: 1
2008_RicardoAugustoRamos.pdf: 3111074 bytes, checksum: 5b6cf5162e1fff5cee3dc0724ece630b (MD5) / Made available in DSpace on 2010-02-10T00:36:20Z (GMT). No. of bitstreams: 1
2008_RicardoAugustoRamos.pdf: 3111074 bytes, checksum: 5b6cf5162e1fff5cee3dc0724ece630b (MD5)
Previous issue date: 2008-12-18 / O emprego de reatores UASB em estações de tratamento de esgotos no Distrito Federal vem sendo bastante difundido desde o início dos anos 1990, atendendo mais de um milhão de habitantes (POE/CAESB, 2005). Por outro lado, os problemas relativos ao manejo adequado do lodo produzido nos reatores ainda não foram suficientemente solucionados, gerando demandas crescentes de operação e manutenção. Ao avaliar a influência da operação de descarte de lodo no desempenho dos reatores UASB no DF, pretendeu-se determinar uma rotina eficiente de descarte de lodo que minimiza os problemas operacionais observados. Por meio da avaliação do desempenho dos reatores UASB da estação de tratamento de esgotos do Gama, submetidos a diferentes rotinas de descarte de lodo, buscou-se uma forma de generalização dos resultados para as demais estações de tratamento de esgotos do DF. Após monitoramento de dois reatores UASB da ETE Gama, avaliando os impactos da suspensão do descarte programado de lodo em uma das unidades, verificaram-se remoções médias de 69% de DQO, 86% de DBO e 58% para SST, superiores às observadas durante a operação regularmente adotada (DQO = 61%, DBO = 81%, SST = 44%). A análise estatística, por meio do teste t de Student, revelou que as duas modalidades de operação produziram efluentes de características distintas para DBO e DQO, nos níveis de 5 e 10% de significância e semelhantes para SST e sólidos sedimentáveis, apenas no nível de 5%. Observou-se que o excesso de escuma superficial é preocupante, podendo ter origem no fraco desempenho do tratamento preliminar e na ausência de uma estratégia de descarte de lodos bem definida. Utilizando uma metodologia proposta para amostragem do lodo e da escuma, foi definida uma rotina de periodicidade mensal para os descartes de lodo nos reatores. São ainda sugeridas alterações de projeto nos sistemas de descarte de escuma e para amostragem de lodo nos reatores UASB, buscando reduzir os gastos operacionais e de manutenção das unidades. _______________________________________________________________________________ ABSTRACT / The use of UASB reactors as units of sewage treatment plants (STP) in the Federal District, Brazil, has been much disseminated since the beginning of the years 90, receiving sewage from more than a million inhabitants (POE/CAESB, 2005). On the other hand, the problems related to the appropriate handling of the sludge produced in the UASB reactors were not yet completely solved, generating growing demands on operation and maintenance. When evaluating the local influence of the operation of sludge discard in the UASB reactors’ performance, it was intended to determine an efficient routine of sludge discard for minimizing the observed operational problems. Through the evaluation of the performance of the UASB reactors existing in the Gama sewage treatment plant, which were submitted to different routines of sludge discard, it was searched for a generalization of these results for other sewage treatment plants in the Federal District. Monitoring two UASB reactors in the Gama STP to evaluating the impacts of stopping the intentional discard of sludge in one of the units, it was verified removal efficiencies of 69% for COD, 86% for BOD, and 58% for TSS, which were higher than the observed ones during the regular operation (COD = 61%, BOD = 81%, TSS = 44%). The statistical analysis, using the Student test, showed that the two modalities of UASB reactors operation had produced effluents with distinct characteristics for BOD and COD, in the 5 and 10% significance levels, and that they were similar for SST and Settable Solids, only in the 5% significance level. It was observed that the excess of superficial scum is a problem, which may have its origin in the poor performance of the preliminary treatment and in the absence of a well defined strategy of sludge discard. Employing the proposed methodology for sampling the sludge and the scum inside the UASB reactors, an operational routine of monthly regularity for the sludge discards has been defined for the UASB reactors. Also, project alterations in the systems of discarding of scum and for sampling of sludge in the UASB reactors were suggested, looking for reducing the operational and maintenance expenses.
|
2 |
Avaliação de tratamento integrado de esgotos sanitários e de lodo de tanque séptico em um Reator Anaeróbico Ralf /Tachini, Mário, Belli Filho, Paulo, Universidade Regional de Blumenau. Programa de Pós-Graduação em Engenharia Ambiental. January 2002 (has links) (PDF)
Orientador: Paulo Belli Filho. / Dissertação (mestrado) - Universidade Regional de Blumenau, Centro de Ciências Ambiental.
|
3 |
Aplicação do método respirométrico em wetlands para a determinação de parâmetros cinéticos /Pereira, Ricardo Molto. January 2008 (has links)
Resumo: A presente dissertação refere-se ao trabalho experimental desenvolvido durante programa de pós-graduação strictu sensu da Universidade Estadual Paulista "Júlio de Mesquita Filho", no qual se procurou determinar parâmetros cinéticos para dimensionamento de sistemas de alagados construídos de fluxo descendente, utilizando sistema de aeração artificial e natural. Este tema foi escolhido, pois, apesar do extenso número de trabalhos publicados sobre a aplicação do método respirométrico, muitos se referem a sistemas de lodos ativados, enquanto que para alagados construídos praticamente não existiam estudos apurados sobre o assunto. Esta dissertação contempla revisão bibliográfica de temas de elevada importância para o desenvolvimento e compreendimento dos resultados obtidos no experimento. Dentre estes temas, procurou especificar as definições de alagados construídos com suas respectivas tipificações, processos atuantes de remoção de nutrientes em filtros biológicos, e aplicação do método respirométrico para determinação de parâmetros cinéticos. Trabalhou-se estatisticamente e analiticamente os resultados obtidos no experimento, para comparar em diferentes situações físicas, hidráulicas e de carga aplicada; as respectivas eficiências de remoção de nutrientes e seus parâmetros cinéticos. Deste estudo pôde-se concluir que meio-suportes de maior área superficial, como por exemplo, a areia, apresentou maior quantidade de biomassa ativa aderida ao meio suporte, implicando em menor perda desta, durante a troca de efluente em sistema de bateladas. Já meio-suportes como pedrisco e brita, possuem menor área superficial, porém maior índice de vazios, o que implica na possibilidade de aplicação de uma carga maior quando comparado à areia. Em contrapartida, há maior perda de biomassa ativa na troca do efluente em sistemas... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This dissertation is the experimental work developed during the post-graduate program strictest sense of the Universidade Estadual Paulista "Julio de Mesquita Filho, which sought to establish kinetic parameters for design of systems of constructed wetlands flow downward, using natural and artificial system aeration. This theme was chosen because, despite the extensive number of papers published on the application of the method repirometric, many refer to systems of activated sludge, while that for virtually no flooded constructed studies found on the subject. This work includes review of issues of high importance to the development and understanding of the results of the experiment. Among these issues, sought to specify the definitions of constructed wetlands with their classifying, working processes of removal of nutrients in biological filters, and the method for determining respirométrico kinetic parameters. Was statistically and analytically worked the results obtained in the experiment, to compare situations in different physical, hydraulic and applied load, the respective efficiencies of removal of nutrients and their kinetic parameters. In this study it was concluded that half of greater media surface area, such as the sand, showed greater amount of biomass attached to the active support means, resulting in loss of this, during the exchange of sewage system in batches. Already support such small and media as crushed gravel, have smaller surface area, but higher rate of empty, which implies the possibility of applying a greater load when compared to the sand. In contrast, there is greater loss of biomass in the active exchange of sewage systems in batches, implying the need for mechanisms for trapping of bacteria, such as secondary decanters. / Orientador: José Augusto de Lollo / Coorientador: Eduardo Luiz de Oliveira / Banca: Jorge Hamada / Banca: Luís Fernando Rossi Léo / Mestre
|
4 |
Desenvolvimento e avaliação de um protótipo de estação compacta para tratamento de esgotos em unidades residenciais unifamiliares / Development and evaluation of a prototype of a compact plant for sewage tratment in single-family residencesSilva, Lucas Achaval 15 April 2014 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Civil e Ambiental, 2014. / Submitted by Ana Cristina Barbosa da Silva (annabds@hotmail.com) on 2014-11-07T13:40:34Z
No. of bitstreams: 1
2014_LucasAchavalSilva.pdf: 5493778 bytes, checksum: 4c8ff215bb5edfaa683d1bf16325b930 (MD5) / Approved for entry into archive by Guimaraes Jacqueline(jacqueline.guimaraes@bce.unb.br) on 2014-11-11T12:02:44Z (GMT) No. of bitstreams: 1
2014_LucasAchavalSilva.pdf: 5493778 bytes, checksum: 4c8ff215bb5edfaa683d1bf16325b930 (MD5) / Made available in DSpace on 2014-11-11T12:02:44Z (GMT). No. of bitstreams: 1
2014_LucasAchavalSilva.pdf: 5493778 bytes, checksum: 4c8ff215bb5edfaa683d1bf16325b930 (MD5) / Muitos são os inconvenientes causados por lançamentos indiscriminados de esgoto nos corpos d’água. Considerando a situação sanitária do Brasil e que parte da sua população não é atendida por rede coletora de esgoto, este trabalho teve o objetivo de desenvolver um protótipo de estação compacta para tratamento de esgotos sanitários gerados por unidades residenciais unifamiliares. A metodologia de pesquisa baseou-se no estudo, averiguação da viabilidade e emprego de associação de alguns processos de tratamento de esgoto sanitário que pudessem ser aproveitados em sistemas compactos. A metodologia foi dividida nas seguintes etapas: concepção do sistema; construção do protótipo concebido; instalação do protótipo em residência térrea unifamiliar; operação, manutenção, controle e monitoramento do protótipo durante sete meses e avaliação do protótipo e da tecnologia aplicada. Foi concebido um protótipo modular compacto com formato circular e dividido em três câmaras: a primeira composta por um Tanque Imhoff modificado com decantador laminar, a segunda por um filtro anaeróbio, e a terceira por um filtro anaeróbio com um Decantador Laminar Secundário, fabricado em fibra de vidro e instalado em uma casa térrea no Distrito Federal (DF). O protótipo concebido e operado sob condições reais obteve, na fase estabilizada, eficiência média de remoção de 84,68% de DBO5, 81,15% de DQO, 87,14% de SST, 100% de SSed, 47,01% de ST, 48,54% de STV, 45,13% de STF, 25,17% de fósforo total, 33,09 % de nitrito e 68,50% de nitrato. O efluente do protótipo concebido está em conformidade para lançamento em corpos d’água de nove das treze legislações de Unidades da Federação para características analisadas de Temperatura, pH, DQO, DBO, SST e SSed. Portanto, o protótipo se mostrou uma boa alternativa para tratamento de esgoto doméstico in situ. _____________________________________________________________________________ ABSTRACT / Many are the drawbacks caused by indiscriminate sewage discharges into water bodies. Considering the sanitation condition of Brazil and that part of the population is not served by sanitary sewer, this study aimed to develop a prototype compact station for treatment of sewage generated by single-family residential units. The research methodology was based on the study, investigation of the feasibility and use of association of some processes of wastewater treatment that could be used in compact systems. The methodology consisted of the following steps: system design; construction of the designed prototype; prototype installation in a single-family residence; operation, maintenance, control and monitoring of the prototype for seven months and evaluation of the prototype and of the applied technology. A compact modular prototype has been designed with a circular shape and is divided into three chambers: the first consists of a modified Imhoff Tank having a laminar settler basin, the second is an anaerobic biofilter, and the third is composed by an anaerobic biofilter coupled to a secondary laminar settling tank. The prototype was manufactured in fiber glass and was installed in a single-family house in the Brazilian Federal District (DF). The prototype designed and operated under actual conditions obtained in the stabilized phase average removal efficiencies of 84.68% for BOD5, 81.15% for COD, 87.14% for TSS, 100% for SSed, 47.01% for ST, 48.54% for STV, 45.13 % for STF, 25.17% for total phosphorus, 33.09 % for nitrite and 68.50 % for nitrate. It was showed that the effluent of the prototype is in accordance to the wastewater discharges requirements in water bodies established by nine of the thirteen laws of the Brazilian Federative Units, considering the measured parameters Temperature, pH, COD, BOD, TSS and SSed. Therefore, the prototype proved to be a good alternative for treatment of domestic sewage in situ.
|
5 |
"Wetlands construídos" de fluxo vertical com meio suporte de solo natural modificado no tratamento de esgotos domésticos / Vertical flow constructed wetlands systems with substract of natural soil for domestic wastewater treatmentSilva, Selma Cristina da 28 May 2007 (has links)
Tese (doutorado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Civil e Ambiental, 2007. / Submitted by Kathryn Cardim Araujo (kathryn.cardim@gmail.com) on 2009-10-22T10:54:12Z
No. of bitstreams: 1
Tese_Selma Cristina.pdf: 6588761 bytes, checksum: 853bb99e7edfda6598730d51290db324 (MD5) / Approved for entry into archive by Tania Milca Carvalho Malheiros(tania@bce.unb.br) on 2009-10-22T15:36:57Z (GMT) No. of bitstreams: 1
Tese_Selma Cristina.pdf: 6588761 bytes, checksum: 853bb99e7edfda6598730d51290db324 (MD5) / Made available in DSpace on 2009-10-22T15:36:57Z (GMT). No. of bitstreams: 1
Tese_Selma Cristina.pdf: 6588761 bytes, checksum: 853bb99e7edfda6598730d51290db324 (MD5)
Previous issue date: 2007-05-28 / No Brasil, o índice de atendimento municipal com serviços de esgotamento sanitário é de 52,2% (PNSB, 2000). É, portanto, baixo e há discrepâncias regionais, pois os percentuais de atendimento das regiões Sudeste e Sul são superiores aos do Norte, Nordeste e Centro Oeste. A situação é mais agravante na zona rural, onde grande parte das localidades não é contemplada com esses serviços e quando existem são ineficientes. Visando contribuir para melhoria das condições sanitárias das cidades brasileiras, procurou-se aprimorar os conhecimentos sobre um dos tipos de sistemas naturais, os wetlands construídos que são sistemas tecnologicamente avançados e de baixo custo. Nessa pesquisa foi avaliado o desempenho dos mecanismos de tratamento dos sistemas wetlands construídos de fluxo vertical descendente com meio suporte de solo natural modificado (Latossolo vermelhoamarelo misturado com areia média), plantado com arroz (Oryza sativa L.) irrigado, no tratamento de esgotos domésticos primários. Os mecanismos observados foram de remoção de poluentes e de patógenos presentes nos esgotos e de salinização, sodificação, colmatação, fertilização, degradação da matéria orgânica e transformação do nitrogênio no meio suporte. Foram montados três sistemas experimentais operando com taxas de aplicação de 4cm/d, 8cm/d e 15cm/d, cada um com 3 unidades wetlands construídos (plantado) e 3 controles (sem planta), totalizando 18 unidades. Os sistemas foram operados sob regime de fluxo não saturado, com alimentação intermitente por um período de dez meses e o monitoramento da qualidade do esgoto afluente e dos efluentes teve duração de nove meses. As cargas do esgoto foram aplicadas nas segundas, quartas e sextas, ficando os outros dias em descanso. As eficiências médias de remoção encontradas variaram aproximadamente, de 97 a 99% (DBO); 90 a 98% (SS); 90 a 99% (turbidez); 9 a 37% (CE); 96 a 100% (P); 88 a 94% (N total); 85 a 95% (amônia) e houve aumento de 2 a 116% nas concentrações de nitrato e redução do NMP de coliformes de 1 log a 6 log. As eficiências de remoção entre os wetlands construídos e controles e entre as taxas de esgoto aplicadas não diferiram significativamente. Contudo, a influência positiva da planta foi observada nos processo de nitrificação, e fertilização e colmatação do solo entre outros. _____________________________________________________________________________ ABSTRACT / In Brazil, the municipalities with sewerage system is 52,2% of the total (PNSB, 2000). Therefore, it is low figure and there are regional discrepancies, as the percentage of attendance at the southern and southeastern regions are higher then at the northern northeastern and middle western. The situation is even worse at the rural area, where most localities do not have these services and are insufficient when they do exist. Aiming at contributing for better sanitary condition in this country, we tried to improve our understanding of a natural system, the constructed wetlands, which are technically advanced systems with low costs (Bird, 2004). In this study we evaluated the performances of the treatment processes, that occurs at wetland systems constructed under vertical descendent flux on modified natural soil substrate ( yellow red-latosoil mixed with medium sand), planted with irrigated rice (Oryza sativa L.), as a biological reactor projected for the treatment of domestic sewage after primary treatment. We built three experimental systems and each of them had 3 units of constructed wetlands (planted) and 3 control units (without plants), giving a total of 18 units. Systems were operated on unsaturated flux regimes, with intermittent availability. The sewage loads were done on Mondays, Wednesdays and Fridays. Systems were operated during 10 months and surveys on sewage and effluent quality were done during nine months. The load did not interfere on the efficiency of pollutants removal, as there was no significant difference between treatments. Mean removal efficiency varied from, approximately, 97 to 99% (BOD); 90 a 98% (SS); 90 a 99% (turbity); 9 a 37% (CE); 90 a 99,9999% (faecal coliform); 96 a 100% (P); 88 a 94% (total N); 85 a 95% (ammonia) and increased from 2 to 116% (nitrate). The removal efficiencies between the wetlands and the controls did not differ significantly. However, the positive influence of irrigated rice was perceived on the nitrification and fertilization processes and soil clogging among others.
|
6 |
Análise integrada da tecnologia microaeróbia como estratégia de dessulfurização In-Situ / Integrated analysis of microaerobic technology as an on-site desulfurization strategySousa, Márcia Rodrigues de 25 August 2016 (has links)
SOUSA, M. R. Análise integrada da tecnologia microaeróbia como estratégia de dessulfurização In-Situ. 2016. 153 f. Tese (Doutorado em Engenharia Civil: Saneamento Ambiental) – Centro de Tecnologia, Universidade Federal do Ceará, Fortaleza, 2016. / Submitted by Hohana Sanders (hohanasanders@hotmail.com) on 2017-02-14T10:10:04Z
No. of bitstreams: 1
2016_tese_mrsousa.pdf: 2372349 bytes, checksum: 7db626c45033c8c0887632e504ce8014 (MD5) / Approved for entry into archive by Marlene Sousa (mmarlene@ufc.br) on 2017-02-23T11:51:12Z (GMT) No. of bitstreams: 1
2016_tese_mrsousa.pdf: 2372349 bytes, checksum: 7db626c45033c8c0887632e504ce8014 (MD5) / Made available in DSpace on 2017-02-23T11:51:12Z (GMT). No. of bitstreams: 1
2016_tese_mrsousa.pdf: 2372349 bytes, checksum: 7db626c45033c8c0887632e504ce8014 (MD5)
Previous issue date: 2016-08-25 / Several studies, mainly related to the anaerobic digestion of solid wastes and sewage with high sulfate concentration, describe the advantages of the microareasure both for the treatment of the biogas and for the improvement of the efficiency of the system as a whole. However, a better understanding of the process is required for low sulphate sewage, as in the case of sanitary sewage, as well as a deeper understanding of the engineering aspects, both in the design of the system and in the operational aspects. In this sense, the best location for atmospheric air dosing or use of pure oxygen, flow rate to be applied, diffusion devices for microaeration, process control, evaluation of the system when subjected to shocks and interruption of aeration etc. can be cited. , As well as aspects related to microbial participation and economic and life cycle studies. The objective of the present study was to conduct an integrated analysis of microaerobic technology as an in-situ desulphurisation strategy for effluents with low sulphate concentration. To do so, the engineering aspects were evaluated, such as the best microaeration flow and best application point, as well as the quality of the biogas generated with the in-situ technology, compared to the ex-situ technology of chemical absorption with hydroxide Sodium, being in this the biogas generated during the operation of an anaerobic reactor. In all periods of study, the microbial population dynamics of the Bacteria and Archaea domains were evaluated by means of molecular techniques such as PCR / DGGE. Finally, an economic analysis and a life cycle assessment (LCA) of the microaeration were carried out in relation to the chemical absorption. Experiments were conducted in parallel with two continuous flow reactors: R1 (Alkaline with alkaline absorption of the generated biogas) and R2 (microaerobic), in order to compare the desulfurization efficiency of the biogas by the different technologies studied. The reactors were fed with synthetic effluent and microaeration that consisted of the injection of atmospheric air, initially in the headspace, but which extended to other points in the sludge blanket of the reactor. In general, the microaerobic system has proved to be very attractive in all engineering, economic and life cycle aspects evaluated, as well as operational stability, and can be considered as an effective technique for in situ effluent desulphurisation With low sulphate concentration. / Diversos estudos, principalmente ligados à digestão anaeróbia de resíduos sólidos e esgotos com elevada concentração de sulfato, descrevem as vantagens da microareção tanto para o tratamento do biogás quanto para melhoria da eficiência do sistema como um todo. Contudo, necessita-se ainda de um melhor entendimento do processo para esgotos com baixa concentração de sulfato, como no caso dos esgotos sanitários, assim como um maior aprofundamento nos aspectos de engenharia, tanto na concepção do sistema quanto nos aspectos operacionais. Nesse sentido, podem ser citados qual o melhor local para dosagem do ar atmosférico ou uso de oxigênio puro, vazão a ser aplicada, dispositivos de difusão da microaeração, controle do processo, avaliação do sistema quando submetido a choques e a interrupção da aeração etc., além dos aspectos ligados à participação microbiana e a estudos econômicos e de ciclo de vida. O presente estudo teve como objetivo geral realizar uma análise integrada da tecnologia microaeróbia como estratégia de dessulfurização in-situ para efluentes com baixa concentração de sulfato. Para tanto, foram avaliados os aspectos de engenharia, como a melhor vazão de microaeração e melhor ponto de aplicação, assim como a qualidade do biogás gerado com a tecnologia in-situ, em comparação com a tecnologia ex-situ de absorção química com hidróxido de sódio, sendo, nesta, o biogás gerado durante a operação de um reator anaeróbio. Em todos os períodos de estudo, a dinâmica populacional microbiana dos domínios Bacteria e Archaea foi avaliada por meio de técnicas moleculares como PCR/DGGE. Por fim, foi realizada uma análise econômica e uma avaliação de ciclo de vida (ACV) da microaeração em relação à absorção química. Foram conduzidos experimentos em paralelo com dois reatores de fluxo contínuo: R1 (Anaeróbio com absorção alcalina do biogás gerado) e R2 (microaeróbio), a fim de comparar a eficiência de dessulfurização do biogás pelas diferentes tecnologias estudadas. Os reatores foram alimentados com efluente sintético e microaeração que consistia na injeção de ar atmosférico, inicialmente no headspace, mas que se extendeu para outros pontos na manta de lodo do reator. De uma forma geral, o sistema microaeróbio se revelou bastante atrativo em todos os aspectos de engenharia, econômico e de ciclo de vida avaliados, assim como de estabilidade operacional, podendo ser considerado como uma técnica efetiva para o processo de dessulfurização in-situ de efluentes com baixa concentração de sulfato.
|
7 |
Efeitos das lagoas de tratamento de esgoto sobre seu entorno: casos no Pontal do ParanapanemaSanti, Lais Jerônimo de [UNESP] 09 April 2014 (has links) (PDF)
Made available in DSpace on 2015-12-10T14:22:52Z (GMT). No. of bitstreams: 0
Previous issue date: 2014-04-09. Added 1 bitstream(s) on 2015-12-10T14:29:03Z : No. of bitstreams: 1
000854496.pdf: 16664585 bytes, checksum: 64eb57a07dbd3310214b1b868c5538bd (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Os municípios de Teodoro Sampaio, Marabá Paulista e Regente Feijó, além de serem municípios de pequeno porte, possuem a característica em comum de tratarem seus esgotos através de lagoas de estabilização. O objetivo desta pesquisa é avaliar o reflexo do tratamento no corpo hídrico receptor e os efeitos em seu entorno, apresentando a caracterização física dos locais e a qualidade das águas. Para tal, foram realizados ensaios de permeabilidade e tamanho dos grãos nos solos antropogênicos, análise da carga orgânica afluente e efluente às lagoas e aplicação do IQA (índice de qualidade das águas) a montante, no ponto de lançamento e à jusante. Os resultados obtidos evidenciaram solos, no entorno das lagoas, arenosos e permeáveis e, qualidade das águas, classificadas de ruim a péssimas. Em relação ao potencial de autodepuração dos corpos hídricos ficou evidente que, após determinada distância, há recuperação do meio, visualizada e comprovada pelas análises químicas. O tratamento realizado pelas lagoas de estabilização é satisfatório, no entanto a eficiência do tratamento pode ser melhorada, através de verificação e correção de todas as variáveis operacionais, bem como revisão de projeto / The municipalities of Teodoro Sampaio, Maraba Paulista and Regente Feijo, like the majority of small municipalities, have the common characteristic of treat their sewage through stabilization ponds. The objective of this research is to evaluate the effects of treatment in the receiving water body and the effects on its surroundings, with the physical characterization of the sites and of the water quality. To this purpose, permeability tests and grain size in anthropogenic soils, analysis of influent organic loading and effluent ponds and the implementation of IQA index (water quality) were performed upstream, at the point of release and downstream. The results showed that soil surrounding the lagoons are sandy and permeable, and water quality, classified bad to very bad. Regarding the potential for self-purification of water bodies became evident that, after a certain distance, there is recovery of the water stream wich is visualized and confirmed by chemical analysis. The treatment by stabilization ponds is satisfactory, however the treatment efficiency can be improved through verification and correction of all operating variables and design review
|
8 |
Atributos químicos do solo fertirrigado com efluente de esgoto tratado e fenometria de cultura do pimentãoSilva Júnior, Waltoíres Reis da 31 May 2016 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Agronomia e Medicina Veterinária, Programa de Pós-Graduação em Agronomia, 2016. / Submitted by Fernanda Percia França (fernandafranca@bce.unb.br) on 2016-07-04T12:56:15Z
No. of bitstreams: 1
2016_WaltoíresReisdaSilvaJúnior.pdf: 1515447 bytes, checksum: 9adbe08252db4f2fba5e2ac531072842 (MD5) / Approved for entry into archive by Raquel Viana(raquelviana@bce.unb.br) on 2016-07-18T18:13:57Z (GMT) No. of bitstreams: 1
2016_WaltoíresReisdaSilvaJúnior.pdf: 1515447 bytes, checksum: 9adbe08252db4f2fba5e2ac531072842 (MD5) / Made available in DSpace on 2016-07-18T18:13:57Z (GMT). No. of bitstreams: 1
2016_WaltoíresReisdaSilvaJúnior.pdf: 1515447 bytes, checksum: 9adbe08252db4f2fba5e2ac531072842 (MD5) / Com a crescente conscientização de que a água é um recurso natural limitado e de expressivo valor econômico, técnicas de uso sustentável e racional são cada vez mais difundidas. Dentre elas, o uso de efluentes de esgoto tratado (EET) para fins de irrigação se destaca, tanto pelo reaproveitamento da água, como pelo aporte de nutrientes ao solo e redução dos danos ambientais. Este trabalho objetiva avaliar o efeito da utilização de EET, proveniente de sanitários de um refeitório, na cultura do pimentão (Capsicum annuum L.), híbrido Canário F1. Foi avaliada a uniformidade de distribuição de água do sistema de irrigação por gotejamento, a quantidade de nutrientes adicionados ao solo, as alterações químicas e físicas de um Latossolo Vermelho Amarelo e o desenvolvimento das plantas e dos frutos em um ciclo da cultura. Os tratamentos utilizados foram: água de córrego, EET, água de córrego com adubação de base, EET com adubação de base, EET com adubação de cobertura e EET com adubação de cobertura e de base. O uso de EET não interfere nos índices de uniformidade de distribuição e coeficiente de uniformidade estatístico do sistema de irrigação por gotejamento. Ao final do experimento, a tendência é de que os teores de fósforo, matéria orgânica e pH no solo irrigado com EET apresente maior elevação em relação aos tratamentos com irrigação com água do córrego. A massa úmida, perímetro e produção total dos frutos de pimentão são maiores nos tratamentos irrigados com EET. A aplicação de EET sem adubação química resulta em maior produção e altura de frutos. A irrigação com EET proporciona maior produção de frutos de pimentão amarelo e melhora as condições químicas do solo. O uso de EET proporciona benefícios no desenvolvimento e produção da cultura do pimentão amarelo e melhora as condições químicas do Latossolo vermelho amarelo. ________________________________________________________________________________________________ ABSTRACT / With the growing awareness that water is a limited natural resource and significant economic value, sustainable and rational use of techniques are increasingly widespread. Among them, the use of treated sewage effluent (TSE) for irrigation purposes stands out both for the reuse of water, as the nutrient supply to the soil and reducing environmental damage. This study aims to evaluate the effect of the TSE, from toilets of a refectory in sweet pepper (Capsicum annuum L.), hybrid canary F1. We evaluated the uniformity of distribution of water from a drip irrigation system, the amount of nutrients added to the soil, the chemical and physical changes of a oxisol and development of plants and fruits in a crop cycle. The treatments were: Stream of water, TSE, stream water based fertilizer, TSEs based fertilizer, topdressing with TSE and TSE with topdressing and base. The use of TSE does not interfere with uniform distribution ratios and statistical uniformity coefficient of the drip irrigation system. At the end of the experiment, the trend is that the phosphorus, organic matter and pH in soil irrigated with TSE presenting the highest elevation in relation to treatment with irrigation stream water. The wet mass, circumference and total production of chilli fruits are higher in treatments irrigated with TSE. The application of TSE without chemical fertilization results in increased production and high fruit. The irrigation with TSE provides greater production of fruits of yellow pepper and improves chemical soil conditions. The use of TSE provides benefits in the development and culture of production of yellow pepper and improves chemical conditions Oxisol.
|
9 |
Aplicação do sistema combinado por filtro anaeróbio seguido de biofiltro aerado submerso ao tratamento de esgotos sanitários de unidades residenciais unifamiliares / Application of a combined system composed by anaerobic filter followed by submerged aerated biofilter to the treatment of sanitary sewage from householdsSilva, Thallyta Manuela Rosário da 15 August 2016 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Civil e Ambiental, 2016. / Submitted by Fernanda Percia França (fernandafranca@bce.unb.br) on 2016-09-26T17:01:16Z
No. of bitstreams: 1
2016_ThallytaManuelaRosáriodaSilva.pdf: 2205216 bytes, checksum: 55fdbd4c83acc1db41268a5075fe7434 (MD5) / Approved for entry into archive by Raquel Viana(raquelviana@bce.unb.br) on 2017-01-11T19:04:21Z (GMT) No. of bitstreams: 1
2016_ThallytaManuelaRosáriodaSilva.pdf: 2205216 bytes, checksum: 55fdbd4c83acc1db41268a5075fe7434 (MD5) / Made available in DSpace on 2017-01-11T19:04:21Z (GMT). No. of bitstreams: 1
2016_ThallytaManuelaRosáriodaSilva.pdf: 2205216 bytes, checksum: 55fdbd4c83acc1db41268a5075fe7434 (MD5) / Metade da população brasileira não possui rede de coleta de esgoto, contaminando solos, rios, mananciais e praias, com impacto direto à saúde pública, causando inúmeras doenças, entre elas a diarreia, hepatite A e poliomielite, atingindo todas as idades, porém as crianças são as mais afetadas. Frente a essa realidade foi idealizado um sistema combinado de tratamento de esgotos construído em escala de bancada, por Filtro Anaeróbio (FAn) seguido de Biofiltro Aerado Submerso (BAS), cujos volumes útil foi de aproximadamente 20 litros e 9 litros, respectivamente, utilizando como meio suporte espuma de poliuretano envolta em anel de polipropileno, o sistema foi operado por um período de 115 dias e teve o seu desempenho avaliado ao tratar água residuária sintética (ARS) simulando um esgoto sanitário, proveniente de tanque imhoff, de uma unidade residencial unifamiliar. Durante a fase de partida, inicialmente, o sistema operou com vazão média de 0,02 m³/d, e teve aumentada a vazão para 0,04 m³/d na fase de equilíbrio dinâmico. Na fase estabilizada, que teve duração de 67 dias, o sistema operou com Taxa de Aplicação Superficial (TAS) de 0,6 e 1,3 m³/m².d, no FAn e BAS, respectivamente, e apresentou eficiência global média de remoção de 97% de DBO5 com concentração média do efluente de 12 mg/L, 94% de DQO com concentração média do efluente de 30 mg/L, 89% de SST com concentração média do efluente de 6 mg/L, 100% de SSed, 94% de nitrogênio total com concentração média do efluente de 4 mg/L. A produção de lodo foi estimada em 0,03 kgSST/KgDQOaplicada para o FAn e 0,06 kgSST/KgDQOaplicada para BAS. O efluente desse sistema combinado de tratamento de esgotos, nas condições em que operou, apresentou redução da produção de lodo e atendeu as condições e padrões de Temperatura, pH, DBO, SST e SSed previstos pela legislação brasileira, podendo ser lançado em corpos d’água. Portanto, o sistema combinado de tratamento de esgotos por FAn seguido de BAS, com meio suporte constituído por espuma de poliuretano envolta em anel de polipropileno, se mostrou uma alternativa eficiente para tratamento de esgoto doméstico unifamiliar, previamente tratado por tanque imhoff. __________________________________________________________________________________________________ ABSTRACT / Half of the Brazilian population does not have a available sewerage system, defiling soil, rivers, springs and beaches, with direct impact on public health, causing numerous diseases, like diarrhea, hepatitis A and poliomyelitis, reaching all ages, although children are the most affected. Facing this situation, it was designed a combined system of sewerage treatment built in bench scale, A combined treatment system composed by Anaerobic Filter (AnF) followed by Submerged Aerated Biofilter (BAS) was conceived, dimensioned and built in bench scale, using a support consisted of polyurethane foam wrapped by polypropylene ring. This combined system was operated and had evaluated its performance when treating synthetic wastewater simulating sewage from a household (SWW). This treatment system was monitored for 115 days. During the inoculation phase, this system initially operated with a 0.02 m³/d flow rate, and, after this, with 0.04 m³/d, during the stabilized phase. During the stabilized phase, which lasted 67 days, the system operated with a 0.6 and 1.3 m³/m².d TAS, in AnF and BAS respectively, and obtained an average global efficiency of BOD5 removal of 97% with an effluent average concentration of 12 mg/L, 94% of COD removal with an effluent average concentration of 30 mg/L, 89% of TSS removal with an effluent average concentration of 6 mg/L, 100% of SSed. The production of sludge was estimated in 0.03 kgSST/kgCOD for the AnF and 0.06 kgSST/kgCOD for the BAS. This combined sewage treatment system presented low sludge production and reached the limits of sanitary sewage release in water bodies to analyzed characteristics of Temperature, pH, COD, BOD, TSS and SSed, considering the Brazilian standards for waterbodies protection. Therefore, the combined treatment system composed by Anaerobic Filter (AnF) followed by Submerged Aerated Biofilter (BAS) has shown to be an efficient alternative to the treatment of domestic sewage from households, previously treated by imhoff tank.
|
10 |
Ozonização como pós-tratamento de efluente de esgoto domésticoCamilo Júnior, Osli Barreto 22 February 2018 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Agronomia e Medicina Veterinária, Programa de Pós-Graduação em Agronomia, 2018. / Submitted by Fabiana Santos (fabianacamargo@bce.unb.br) on 2018-08-20T19:43:11Z
No. of bitstreams: 1
2018_OsliBarretoCamiloJúnior.pdf: 1184807 bytes, checksum: b209ead832966f07a75cb8760bfbb64e (MD5) / Approved for entry into archive by Raquel Viana (raquelviana@bce.unb.br) on 2018-08-20T20:17:50Z (GMT) No. of bitstreams: 1
2018_OsliBarretoCamiloJúnior.pdf: 1184807 bytes, checksum: b209ead832966f07a75cb8760bfbb64e (MD5) / Made available in DSpace on 2018-08-20T20:17:50Z (GMT). No. of bitstreams: 1
2018_OsliBarretoCamiloJúnior.pdf: 1184807 bytes, checksum: b209ead832966f07a75cb8760bfbb64e (MD5)
Previous issue date: 2018-08-20 / Dentre as várias opções de tratamento secundário de esgoto, o uso de tanques sépticos seguidos do Sistema de Zona de Raízes (SZR) apresentam características favoráveis, como eficiente remoção de microrganismos, sais e compostos tóxicos. Entretanto, persistem atributos como a cor, turbidez, dentre outros que podem ser reduzidos com tratamento terciário, como a ozonização. Diante do exposto, o objetivo deste trabalho foi avaliar a aplicação da ozonização em efluente de esgotos doméstico tratado em tanques sépticos em série seguidos de SZR. Foram aplicados os tempos de exposição ao ozônio de 0, 30, 60, 90, 120 e 150 min. na dosagem constante de 12 mg L-1 de O3, bem como dosagens de 0, 4, 10, 17, 25 e 35 mg L-1 de O3 durante tempo de exposição de 30 min. Em todos os ensaios, a vazão de ozônio foi ajustada em 1 L min.-1. Foram realizadas sete campanhas de coleta de efluente de diferente composição, sendo que em cada amostra foi analisado o Potencial Hidrogeônico (pH); Condutividade Elétrica (CE), Demanda Química de Oxigênio (DQO), Demanda Bioquímica de Oxigênio (DBO), Oxigênio Dissolvido (OD) Alcalinidade Total (Atotal), Sódio (Na+), Potássio (K+), Amônia (NH3), Turbidez, Cor, Escheria coli, Coliformes Totais, Sólidos Suspensos, Sólidos Dissolvidos e Sólidos Totais. A ozonização promoveu redução significativa de cor e turbidez do efluente até o tempo de 120 min de exposição na dosagem de 12 mg L-1 de O3 e até a concentração de 17 mg L-1 de O3 por 30 min. A condutividade elétrica reduziu 7,0% no tempo de esposição de 120 min. sendo que, de maneira geral, o tempo de exposição é mais efetivo na alteração da CE do que o aumento na dosagem de ozônio. O pH se elevou 12,30% no tempo de 120 e 150 min. e 9,4% na dosagem de 4 mg L-1 de O3; já a alcalinidade se elevou 22,2% na dosagem de 17 mg L-1 de O3 e oxigênio dissolvido de 351% no tempo de 90 min. e 424% na dosagem de 17 mg L-1 de O3. A ozonização não promoveu alterações nos teores de potássio, sódio, amônia, sólidos suspensos, sólidos dissolvidos e sólidos totais. A Escheria coli, coliformes totais, DQO e DBO não apresentaram correlação consistente entre os diferentes tempos de exposição e dosagens de ozônio. / There are several options to treat sewage and the use of septic tanks and the Root Zone System (RZS) presents valuable characteristics, as the remotion of microorganisms, salts and toxic compounds. However, there are persistent attributes such as color, turbidity, among others that can be removed with tertiary treatment, such as ozonization. In view of the above, the objective of this work was to evaluate the application of ozonation in treated domestic sewage effluent in septic tanks in series. Exposure times of 0, 30, 60, 90, 120 and 150 min were applied in the constant dosage of 12 mg L-1 of O3, as well as dosages of 0, 4, 10, 17, 25 and 35 mg L-1 of O3 during the exposure time of 30 min. In all tests, the ozone flow rate was adjusted to 1 L min -1. Seven campaigns of collection of different effluent composition were carried out. In each sample of effluent were analyzed the Potention Hydrogen (pH), Electrical Conductivity (EC), Chemical Oxygen Demand (COD), Biochemical Oxygen Demand (BOD), Dissolved Oxygen (DO), Total Alkalinity (totalA), Sodium (Na+), Potassium (K+), Ammonia (NH3), Turbidity, Color, Escheria coli, Total Coliforms, Suspended Solids, Dissolved Solids and Total Solids. At the exposure time of 120 min and 17 mg L-1 of O3, there was reduction of turbidity of 40.6% and 58.9%; color reduction of 76.2% and 81.5%; and reduction of the electrical conductivity of 7.0% in the time of 120 min. The pH increased by 12.30% in the time of 120 and 150 min and 9.4% in the dosage of 4 mg L-1 of O3; Alkalinity rose 22.2% at the dose of 17 mg L-1 of O3 and dissolved oxygen of 351% at 90 min of exposure and 424% at the dose of 17 mg L-1 of O3. The ozonization does not promote any changes in the contents of potassium, sodium, ammonia, suspended solids, dissolved solids and total solids. E. coli, Total Coliforms, Chemical Oxygen Demand (COD) and Biochemical Oxygen Demand (BOD) did not present a consistent relation between the exposure time and the ozon doses.
|
Page generated in 0.0873 seconds