• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 453
  • 10
  • 9
  • 8
  • 8
  • 4
  • 4
  • 2
  • 1
  • 1
  • Tagged with
  • 476
  • 201
  • 145
  • 123
  • 105
  • 102
  • 98
  • 98
  • 89
  • 85
  • 68
  • 64
  • 63
  • 59
  • 55
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
241

Utilização da técnica da biorremediação em sistemas de esgotamento sanitário. Aplicação na cidade de Juazeiro do Norte, Ceará / Use of bioremediation technique in sewage systems. Application in the town of Juazeiro do Norte, Ceará

Rodrigues, Francisco Preto January 2005 (has links)
RODRIGUES, F. P. Utilização da técnica da biorremediação em sistemas de esgotamento sanitário. Aplicação na cidade de Juazeiro do Norte, Ceará. 2005. 90 f. Dissertação (Mestrado em Engenharia Civil: Saneamento Ambiental) – Centro de Tecnologia, Universidade Federal do Ceará, Fortaleza, 2005. / Submitted by João silva (jpauloqxb@gmail.com) on 2016-06-07T18:58:31Z No. of bitstreams: 1 2005_dis_fprodrigues.pdf: 1957669 bytes, checksum: 821a6c1e101d492f776b79ab4ef89c7c (MD5) / Approved for entry into archive by Marlene Sousa (mmarlene@ufc.br) on 2016-07-20T18:20:25Z (GMT) No. of bitstreams: 1 2005_dis_fprodrigues.pdf: 1957669 bytes, checksum: 821a6c1e101d492f776b79ab4ef89c7c (MD5) / Made available in DSpace on 2016-07-20T18:20:25Z (GMT). No. of bitstreams: 1 2005_dis_fprodrigues.pdf: 1957669 bytes, checksum: 821a6c1e101d492f776b79ab4ef89c7c (MD5) Previous issue date: 2005 / This work evaluated the use of the bioremediation technique by the application of selected microorganisms (biological additives), that accelerate the organic matter degradation, to increase the microbial population in the treatment system, recovering or improving the biological process efficiency in stabilization ponds. The work was developed in the basis of the results from the wastewater samples analysis collected in Malvas wastewater treatment plant, operated by the Company of Water and Wastewater of Ceará (CAGECE) in Juazeiro do Norte, Ceará State. During a 5 (five) month period, it was verified the behavior of the ponds by the analysis of the following parameters: BOD, COD, total and fecal coliforms, settable solids, total suspended solids, electric conductivity, temperature, dissolved oxygen, sulphydric gas and sulfide. The total BOD and COD removals were, respectively, 84 and 80%. The sulphydric gas removal in ponds 1 and 2 were, respectively, 43 and 38%. The dissolved oxygen rate, during the additive application, increased gradually month by month. The maturation pond effluent can be used for unrestricted irrigation, since TFC < 1000/100 mL. The in situ bioremediation process had the objective of applying the technology to help the environment, by reintroducing microorganisms, improving their activity in the biodegradation process. / Este trabalho procurou avaliar o uso da técnica de biorremediação, através da aplicação de microrganismos selecionados (aditivos biológicos), que aceleram o processo de degradação da matéria orgânica, para incrementar a população microbiana no sistema de tratamento, recuperando e/ ou aumentando a eficiência do processo biológico em lagoas de estabilização. O trabalho desenvolveu-se a partir dos resultados de análises laboratoriais de amostras de esgotos coletadas na Estação de Tratamento de Esgoto (ETE - Malvas), operada pela Companhia de Água e Esgotos do Ceará (CAGECE) em Juazeiro do Norte, Ceará. Durante um período de 5(cinco) meses foi verificado o comportamento da série de lagoas, através da análise dos seguintes parâmetros: DBO e DQO, Coliformes Totais e Termotolerantes, Sólidos Sedimentáveis, Sólidos Suspensos Totais, Condutividade Elétrica, Temperatura, Oxigênio Dissolvido, Gás Sulfídrico e Sulfeto. As remoções totais de DBO e DQO foram, respectivamente, de 84 e 80%. As remoções de gás sulfídrico, nas lagoas 1 e 2 foram, respectivamente, de 43 e 38%. A taxa de oxigênio dissolvido, durante a aplicação do aditivo, teve um crescimento gradual mês a mês. O efluente da lagoa de maturação pode ser aproveitado para irrigação irrestrita, uma vez que CTT < 1000/100 mL. O processo utilizado de biorremediação in situ (no local) teve como finalidade utilizar a ciência para ajudar a natureza, através da recolocação de microrganismos fortalecendo a ação dos mesmos no processo de biodegradação.
242

Desempenho de sistema alagado construído para tratamento de esgoto doméstico / Performance of constructed wetland system for the treatment of domestic sewage

Brasil, Mozart da Silva 27 July 2005 (has links)
Submitted by Marco Antônio de Ramos Chagas (mchagas@ufv.br) on 2017-03-09T10:13:35Z No. of bitstreams: 1 texto completo.pdf: 1881185 bytes, checksum: 0e63427a670b7f41983d11a0ddc7d4a4 (MD5) / Made available in DSpace on 2017-03-09T10:13:35Z (GMT). No. of bitstreams: 1 texto completo.pdf: 1881185 bytes, checksum: 0e63427a670b7f41983d11a0ddc7d4a4 (MD5) Previous issue date: 2005-07-27 / Este trabalho teve por objetivo obter os parâmetros da equação de cinética de remoção de carga orgânica e avaliar o desempenho de quatro sistemas alagados construídos (SACs) de 24,0 x 1,0 x 0,3 m, com fluxo subsuperficial no tratamento de efluente doméstico proveniente de tanque séptico. O sistema foi preenchido com brita # 0, como meio-suporte, onde a taboa (Typha sp) foi cultivada, empregando-se dois tempos de residência hidráulica – t (1,9 e 3,8 dias) e diferentes taxas médias de carga orgânica volumétrica (116, 164 e 210 g m 3 d -1 ). Para tanto, foram quantificadas as seguintes variáveis: demanda química de oxigênio (DQO), sólidos suspensos totais (SST), turbidez, nitrogênio total (N-Total), fósforo total (P-Total), potássio, sódio, condutividade elétrica, potencial redox (Eh) e pH. Os parâmetros K V e n do modelo cinético de remoção de carga orgânica foram obtidos por regressão não-linear. Com exceção do sódio, cuja concentração efluente não foi reduzida, o sistema de tratamento apresentou eficiência na remoção das variáveis avaliadas, pois, foram obtidas médias de 87%, 81%, 91%, 88%, 33%, 35% e 35% para DQO, DQO solúvel, SST, turbidez, N- Total, P-Total e potássio, respectivamente, nos SACs 1, 2 e 4 e de 90%, 85%, 91%, 86%, 57%, 48% e 52%, respectivamente, no SAC 3. As taxas de carga orgânica não tiveram influência negativa na remoção de poluentes, com exceção da eficiência de remoção de fósforo que decresceu com o aumento das taxas de aporte deste nutriente em dos dois SACs avaliados. O t de 3,8 dias foi mais efetivo na remoção dos poluentes do que o t de 1,9 dias, com exceção de SST que não variou durante a remoção, embora o t de 1,9 dias tenha sido suficiente para produzir um efluente que atendesse aos padrões de lançamento em corpos hídricos receptores, em conformidade com a legislação ambiental do Estado de Minas Gerais. O modelo de remoção de 1a ordem de carga orgânica não se ajustou bem aos dados, enquanto o modelo de remoção modificado e proposto neste trabalho (Ce/Ca = exp(-K t n ) teve bom ajuste e descreveu, adequadamente, a cinética de remoção de carga orgânica no sistema avaliado. / This study was carried out to obtain the parameters of the kinetics equation of the organic load removal and to evaluate the performance of four constructed wetland systems (SACs) measuring 24.0 x 1.0 x 0.3 m with subsurface flow in treatment of the domestic effluent proceeding from septic tank.. The system was infilled with gravel # 0 as a support medium where the cattail plant (Thypha sp) was cropped, by operating under two times of hydraulic residence - t (1.9 and 3.8 days) and different average rates of volumetric organic loads (116, 164 and 210 g m 3 d -1 . So, the following variables were quantified: chemical oxygen demand (DQO), total suspended solids (SST), turbidity, total nitrogen (total-N), total phosphorus (total-P), potassium, sodium, electric conductivity, redox potential (Eh), and pH. The parameters K V and n of the kinetic model of the organic load removal were obtained by nonlinear regression. Except for sodium, from which the effluent concentration was not reduced, the treatment system showed to be efficient in removing the evaluated variables, since averages of 87%, 81%, 91%, 88%, 33%, 35% and 35% were respectively obtained for DQO, soluble DQO, SST, turbidity, total-N, total-P, and potassium in SACs 1, 2 and 4, as well as 90%, 85%, 91%, 86%, 57%, 48% and 52%, respectively, in SAC 3. The organic load rates had no negative influence negatively on the removal of pollutants, except for the efficiency in the removal of phosphorus that was decreased with the increased supply rates of this nutrient in two of the evaluated SACs. The 3.8-day time (t) was more effective than the 1.9-day time in removing the pollutants, except for SST that did not varied over their removal, although the 1.9-day time was enough to produce such an effluent that would satisfy to the discharge patterns in the water-receiving bodies according to Minas Gerais State’s environmental legislation. The first-ordered removal model of the organic load did not satisfactorily adjusted to the observed data, whereas the modified removal model and proposed in this work (Ce/Ca = exp(-K t n ) showed a good adjustment, besides describing appropriately the kinetics of the organic load removal in the evaluated system. / Tese importada do Alexandria
243

Alterações Física e Químicas do Solo e estado Nutricional do Cafeeiro em Resposta à Fertirrigação com Água Residuária de Origem Doméstica / Soil Physical and Chemical Alterations and coffee Nutritional status in response to Fertirrigation with Domestic wastewater

Medeiros, Salomão de Sousa 14 February 2005 (has links)
Submitted by Marco Antônio de Ramos Chagas (mchagas@ufv.br) on 2017-03-09T13:54:05Z No. of bitstreams: 1 texto completo.pdf: 650609 bytes, checksum: 4924b738f52bf05600cce870964b9e86 (MD5) / Made available in DSpace on 2017-03-09T13:54:05Z (GMT). No. of bitstreams: 1 texto completo.pdf: 650609 bytes, checksum: 4924b738f52bf05600cce870964b9e86 (MD5) Previous issue date: 2005-02-14 / Conselho Nacional de Desenvolvimento Científico e Tecnológico / A oferta de água no mundo tem relação estreita com a segurança alimentar, o estilo de vida das pessoas, o crescimento industrial e agrícola e a sustentabilidade ambiental. Nas regiões áridas e semi-áridas, a água tornou-se fator limitante para o desenvolvimento urbano, industrial e agrícola. O Brasil, apesar de apresentar uma disponibilidade elevada de recursos hídricos, cerca de 257.790 m 3 s -1 , aproximadamente 17,3% dos recursos hídricos do planeta, a possui de forma desigual. Dos nove estados do Nordeste, cinco (Rio Grande do Norte, Paraíba, Pernambuco, Alagoas e Sergipe) já sinalizam a escassez hídrica, por apresentar uma disponibilidade menor que 1.700 m 3 hab -1 ano -1 . Neste contexto de escassez de água, associada aos problemas de qualidade surge, como alternativa, a utilização da água residuária. Neste sentido, objetivou-se, investigar as alterações física e químicas do solo e o estado nutricional do cafeeiro, em resposta à fertirrigação com água residuária filtrada de origem doméstica e comparar os resultados com aqueles obtidos com o manejo convencional. As características física e químicas do solo monitoradas, foram: P, K + , Na + , Ca 2+ , Mg 2+ , Al 3+ , H + Al, matéria orgânica (MO), N – total, P – remanescente, Zn, Fe, Mn, Cu, B, S, pH, condutividade elétrica do extrato da pasta saturada do solo (CE), argila dispersa em água (ADA), razão de adsorção de sódio (RAS) e porcentagem de sódio trocável (PST); nas folhas do cafeeiro foram monitoradas as concentração de N, P, K, Ca, Mg, S, Zn, Fe, Mn, Cu e B. O experimento foi implantado na Unidade Piloto de Tratamento de água residuária e Agricultura Irrigada, localizada na Universidade Federal de Viçosa – UFV, pertencente ao Departamento de Engenharia Agrícola – DEA. O delineamento experimental constituiu-se de 18 unidades experimentais, cada uma composta de oito plantas. O experimento foi montado segundo o esquema de parcelas subdivididas, tendo nas parcelas os tipos de manejo adotados (convencional – MC e com água residuária de origem doméstica – MR com aplicação de cinco diferentes lâminas) e nas subparcelas, as faixas de profundidades do solo (0 – 0,20; 0,20 – 0,40 e 0,40 – 0,60 m) no delineamento em blocos casualizados (linhas de plantio) com três repetições. O período de monitoramento das alterações física e químicas do solo e do estado nutricional do cafeeiro, foi de 270 dias, sendo que a cada 90 dias eram realizadas amostragens do solo e a coleta de amostras foliares, para verificar o efeito dos manejos ao longo do tempo. O MC (tratamento T 1 ), constituiu-se de calagem, adubação convencional e irrigação suplementar com água da represa. No MR foram aplicadas cinco diferentes lâminas de água residuária filtrada de origem doméstica (tratamentos: T 2 , T 3 , T 4 , T 5 e T 6 ) as quais variaram de acordo com o tempo. No tempo 1 – T p1 (após 90 dias, a adoção dos manejos) as lâminas de água residuária aplicadas totalizaram: 117, 146, 234, 264 e 293mm. No tempo 2 – T p2 (após 180 dias, a adoção dos manejos) 155, 197, 309, 360 e 399mm e no tempo 3 – T p3 (após 270 dias, a adoção dos manejos) 202, 262, 399, 468 e 532 mm. Os resultados mostraram que: quanto ao aspecto de salinidade, a água residuária de origem doméstica não apresentou qualquer grau de restrição de uso, porém, avaliando-a quanto ao risco potencial de provocar problemas de infiltração no solo, a água apresentou restrição de uso, de ligeiro a moderado. No que se refere à toxicidade de íons específicos, a água residuária não indicou restrições de uso, por apresentar uma concentração de Na + menor que 69 mg L -1 . O valor médio do pH da água residuária foi considerado médio, estando de acordo com a faixa normal para uso na irrigação. As concentrações médias de Zn e Mn estão de acordo com as diretrizes para uso na irrigação por longos períodos; já as concentrações médias de Cu e Fe estão um pouco acima do recomendado se a lâmina aplicada for maior de 1200 mm ano -1 . Quanto à influência da qualidade da água residuária de origem doméstica no surgimento de problemas de obstrução no sistema de irrigação localizada, a concentração de sólidos suspensos não proporcionou nenhum grau de restrição; no entanto, apresentou grau de restrição de ligeira a moderada para o pH e concentração de Mn e severa para concentração de Fe. A aplicação de água residuária filtrada de origem doméstica foi eficaz no suprimento das necessidades hídricas do cafeeiro e, devido à sua composição química, possibilitou melhoria na fertilidade do solo e do estado nutricional do cafeeiro. Os principais impactos positivos observados no solo em resposta à adoção do MR, foram: aumento do pH, das concentrações de P disponível, K + , Ca 2+ , Mg 2+ e S trocáveis, MO, N –total e diminuição da acidez trocável e potencial e ADA, enquanto os impactos negativos verificados no solo em decorrência do MR, foram: incremento nas concentrações de Fe, Mn e B disponíveis, Na + trocável, aumento da CE, RAS e PST. Apesar do aumento da CE do solo no MR, não se constataram problemas de salinização no solo, por apresentar CE < 2000 μS cm -1 . Avaliando os valores da PST (< 7%), verificou-se que o solo não apresenta comprometimento da sua estrutura; já avaliando a CE e PST do solo conjuntamente, o solo submetido ao MR foi classificado como normal. De maneira geral, o MR foi mais efetivo na melhoria do estado nutricional do cafeeiro, do que o MC, pois as concentrações dos principais nutrientes (N, Ca, Mg, S, Zn e Cu) ficaram dentro dos níveis considerados adequados. Os nutrientes passíveis de causar problemas de toxicidade ao cafeeiro, são o Fe e Mn. Do ponto de vista ambiental, a disposição de água residuária no solo pode vir como alternativa para o tratamento dessas águas, além de potencializar a produção de alimentos. / Water availability in the world has a close relationship with food security, people's lifestyle, industrial and agricultural growth and environmental sustainability. In regions with arid and semi-arid climates, water has become a limit factor for urban, industrial and agricultural development. In spite of a high availability of water resources in Brazil (around 257.790 m 3 s -1 ), approx. 17,3% of the planet’s water resources, it is unequally distributed. Five in nine Northeast states, (Rio Grande do Norte, Paraíba, Pernambuco, Alagoas and Sergipe) already signal shortage of water, as their water availability is lower than 1.700 m 3 inhab -1 year -1 . In the context of water shortage associated to problems of water quality, the use of wastewater appears to be a feasible alternative. Therefore, the objective of this work was to investigate soil physical and chemical alterations and the coffee plant nutritional status, in response to fertirrigation with filtered domestic wastewater and to compare the results with the conventional agricultural management. The assayed soil physical and chemical characteristics were: P, K + , Na + , Ca 2+ , Mg 2+ , Al 3+ , H + Al, organic matter (OM), total N, remaining P, Zn, Mn, Cu, B, S, pH, electric conductivity of soil saturated paste extract (EC), clay dispersion in water (CDW), sodium adsorption ratio (SAR) and exchangeable sodium percentage (ESP); coffee leaves were assayed for the concentration of N, P, K, Ca, Mg, S, Zn, Fe, Mn, Cu and B. The experiment was carried out at the Sewer Treatment Pilot Plant (EPTE), DEA/UFV. The experimental design consisted of 18 plots, with eight plants each. The treatments were distributed in split-plots, the plots having the adopted management types (CM-conventional and with WM-domestic wastewater with five different water laminas) and the subplots with soil depths (0 – 0.20; 0.20 – 0.40 and 0.40 – 0.60 m) in randomized block design (planting lines) with three repetitions. Soil physical and chemical alterations and coffee nutritional status were monitored for 270 days. Soil samplings and leaf sample collection were carried out to verify the effect of management along the time every 90 days. CM (treatment T 1 ) consisted of liming, conventional fertilization and supplemental irrigation with dam water. In WM five different filtered domestic wastewater laminas were applied (treatments: T 2 , T 3 , T 4 , T 5 and T 6 ) varying with time. In time 1 - T p1 (after 90 days, adoption of management), totaling 117, 146, 234, 264 and 293 mm of water. In time 2 - T p2 (after 180 days, adoption of management) 155, 197, 309, 360 and 399 mm and in time 3 - T p3 (after 270 days, adoption of management) 202, 262, 399, 468 and 532 mm. The results showed that in relation to salinity, the domestic wastewater present no restriction of use, however the use restriction was from light to moderate when evaluating for the potential risk of causing soil infiltration. There were no use restrictions for specific ion toxicity, as Na+ concentration was lower than 69 mg L -1 . The wastewater average pH was medium, in the normal range for irrigation use. Mean Zn and Mn concentrations are in accordance with the guidelines for the irrigation use for long periods; however the mean Cu and Fe concentrations are a little above the recommendation if the applied lamina is larger than 1200 mm year -1 . As for the influence of the domestic wastewater quality on the occurrence of clogging problems in the localized irrigation system, the suspended solids concentration provide no restriction; however, there was a light to moderate restriction for pH and Mn concentration and severe for Fe concentration. The application of filtered domestic wastewater was effective in providing the water needed for the plants and, due to its chemical composition, to improve soil fertility and coffee nutritional status. The major positive impacts observed in the soil in response to the WM adoption were increase in pH, the concentrations of available P, exchangeable K + , Ca 2+ , Mg 2+ and S, OM, total-N and decrease in the exchangeable and potential acidity and ADA. The negative impacts verified in the soil due to WM were increase in the concentrations of available Fe, Mn and B, exchangeable Na + , increase in EC, RAS and PST. In spite of the increase in soil EC in WM, there were no problems of soil salinity, since EC < 2000 μS cm -1 . When evaluating PST values (< 7 %) alone, it was verified that there were no risks to soil structure; yet when evaluating EC and PST together, the soil treated with WM was classified as normal. In general, WM was more effective in improving coffee nutritional status than CM, because the concentrations of the essential nutrients (N, Ca, Mg, S, Zn and Cu) were within the range considered adequate. The nutrients with potential for causing toxicity problems to coffee plants, are Fe and Mn. From the environmental point of view, the disposition of wastewater in the soil could be an alternative to wastewater treatment, besides increasing food production. / Tese importada do Alexandria
244

Efeito do binômio tempo-temperatura de incubação da amostra na demanda bioquímica de oxigênio de diferentes águas residuárias / Effect of binomial time-temperature incubation of the sample in the biochemical oxygen demand of different wastewaters

Matos, Mateus Pimentel de 03 July 2012 (has links)
Submitted by Reginaldo Soares de Freitas (reginaldo.freitas@ufv.br) on 2016-05-30T14:36:49Z No. of bitstreams: 1 texto completo.pdf: 594057 bytes, checksum: 882d63ef020066f2591f90c6fac62809 (MD5) / Made available in DSpace on 2016-05-30T14:36:49Z (GMT). No. of bitstreams: 1 texto completo.pdf: 594057 bytes, checksum: 882d63ef020066f2591f90c6fac62809 (MD5) Previous issue date: 2012-07-03 / Conselho Nacional de Desenvolvimento Científico e Tecnológico / Pesquisas sobre o efeito do tempo e da temperatura de incubação de amostras líquidas, na estimativa da matéria orgânica biodegradável contida nestas, atualmente são raras, tendo em vista que têm sido aceitos, como padrão, os resultados apresentados nos trabalhos clássicos de Streeter e Phelps e de Theriault, divulgados em 1925 e 1927, respectivamente. Entretanto, esses estudos são passíveis de vários questionamentos, principalmente no que se refere às estimativas feitas em amostras de águas residuárias que não sejam o esgoto sanitário ou soluções sintéticas. Dentre as questões pendentes mais instigantes estão a de que seria possível a redução do tempo de incubação das amostras para obtenção da demanda bioquímica de oxigênio (DBO) e que haveria influência da temperatura na demanda bioquímica de oxigênio última (DBOu ) da amostra. Para conhecer o efeito da temperatura nas estimativas de DBO e de DBOu , é necessário, também, entender quais os efeitos da mesma variável na obtenção dos coeficientes de desoxigenação (k) e de temperatura (θ); qual o modelo cinético que melhor descreve a progressão da DBO e o efeito de interferentes nessas análises. Para tanto, foram incubadas amostras de esgotos sanitários tratados em fossa séptica (ESF), águas residuárias de laticínios (ARL) e da suinocultura (ARS), para obtenção do coeficiente de desoxigenação à 20 oC (k20). As mesmas amostras também foram armazenadas sob temperaturas de 30 e 35 oC, por tempo equivalente ao período de incubação de 5 dias e à 20 oC, tempos esses calculados usando a equação de Arrhenius modificada por Streeter e Phelps, obtendo-se, assim, os coeficientes θ30 e θ35. Em outro teste, quantificações de DBO foram feitas em vários dias, usando o esgoto sanitário bruto (ESB), a fim de obter θ a partir dos valores de k20 e k35, e verificando-se se a demanda última varia com a temperatura, com a obtenção do coeficiente de temperatura 20 35 da demanda última (φ) a partir da DBOu e da DBOu . Avaliou-se, também, o efeito da inibição da nitrificação nas amostras sobre os valores estimados de k e, usando os valores de k20 típicos de literatura, também foram estimados os valores de θ, verificando se erros de estimativa de k, implicam em erros significativos do coeficiente de temperatura. Os experimentos foram conduzidos no Laboratório de Qualidade da Água (LQA) do Departamento de Engenharia Agrícola (DEA) da Universidade Federal de Viçosa (UFV). Os valores de θ calculados a partir de k20 obtidos experimentalmente foram de 1,048 para ESF, 1,046 para ARL e 1,020 para ARS, sob a temperatura de 35 o C, e de 1,041, 1,070, 1,028, para as mesmas águas residuárias, quando incubadas à 30 oC. Os valores de θ estimados utilizando-se valores de k20 obtidos na literatura não foram estatisticamente diferentes, em nível de 5% de probabilidade, pelo teste "t". Igual conclusão foi obtida ao se estimar o valor do coeficiente de temperatura, usando o valor de k obtido após novo ajuste do modelo de primeira ordem, utilizando o conjunto de dados depois de expurgo dos dados tardios (não houve diferença significativa). Usando o mesmo teste, verificou-se que o uso do valor de θ de 1,047, recomendado na literatura, não implica em erros significativos na estimativa de k. No segundo experimento, foram obtidos k20 e k35, respectivamente, de 0,1593 e 0,2262 d-1, tendo valor de 20 θ igual a 1,024. Os valores estimados de DBOu 35 e DBOu foram, respectivamente, de 579 mg L-1 e 661 mg L-1. O modelo de segunda ordem apresentou desempenho ligeiramente superior sobre o modelo de primeira ordem, na descrição dos dados. Porém, dada à pequena diferença nos resultados e a simplicidade em sua utilização, o modelo de primeira ordem é, ainda, preferível. Os coeficientes φ ajustados foram de 0,00948 e de 0,00967, respectivamente usando os modelos de primeira e segunda ordens, valores suficientemente pequenos para indicar desprezível ou inexistente variação do valor de DBOu com a temperatura. O aumento na temperatura da amostra proporcionou, no entanto, diferentes valores de θ para as águas residuárias. / Research into the effect of time and temperature incubation of liquid samples, in the estimation of biodegradable organic matter contained in these nowadays are rare, considering that they have been accepted as standard the results presented in classical studies of Streeter and Phelps, and Theriault, released in 1925 and 1927, respectively. However, these studies are subject to various questions, mainly in relation in the estimations made on samples of wastewater other than the sewage or synthetic solutions. Among the outstanding questions, the most intriguing that it would be possible to reduce the incubation time of the samples to obtaining the biochemical oxygen demand (BOD) and that there is effect of temperature on biochemical oxygen demand ultimate (UBOD) of the sample. To determine the effect of temperature on estimates of BOD and UBOD, it is also necessary to understand what the effects of the same variable in obtaining the deoxygenation (k) and temperature coefficients (θ); which the kinetic model that best describes the progression of the BOD and the effect of interferents in these analyzes. Thus, samples of sewage treated in septic tank (ESF), dairy wastewater (ARL) and swine wastewater (ARS) were incubated for obtaining the deoxygenation coefficient at 20 oC (k20). The same samples were also stored at temperatures of 30 and 35 o C, for time equivalent to an incubation period of 5 days and at 20 oC, these times were calculated using the Arrhenius equation modified by Streeter and Phelps, obtaining thereby the coefficients and θ30 θ35. In another test, measurements of BOD were made for several days, using the raw sewage (ESB) to obtain θ from values of k20 and k35, and checking whether the ultimate demand varies with temperature, obtaining the temperature coefficient of the ultimate demand (φ) from UBOD20 and UBOD35 . It was also evaluated the effect of inhibiting the nitrification in the samples on the estimated values of k and, using typical values of k20 literature were estimated values of θ too, verifying if errors in the estimation of k, implying in significant errors in the temperature coefficient. The experiments were conducted at the Laboratory of Water Quality (LQA), Department of Agricultural Engineering (DEA), Federal University of Viçosa (UFV). The values of θ calculated from experimental data of k20 were 1.048 to ESF, 1.046 to ARL and 1.020 to ARS, under a temperature of 35 oC, and 1.041, 1.070, 1.028, for the same wastewater when incubated at 30 oC. The values of θ estimated using values of k20 obtained from the literature were not statistically different at 5% probability, using the "t" test. Same conclusion was obtained when estimating the value of temperature coefficient, using the value of k obtained after new adjust from first order model using the data after the purge of late data (no difference significant). Using the same test, it was found that the use of the value θ of 1.047 recommended in the literature, does not imply significant errors in the estimation of k. In the second experiment were obtained k35 and k20, respectively, 0.1593 and 0.2262 d-1, with θ value of 1.024. The estimated values of UBOD20 and UBOD35 were, respectively, 579 mg L-1 and 661 mg L-1. The second order model performance was slightly higher on the first-order model, in describing the data. However, given the small difference in the results and the simplicity to use, the first order model is also preferred. The results of coefficients φ adjusted were 0.009484 and 0.00967, respectively using the first and second models, values sufficiently small to show no or negligible value UBOD variation with temperature. The increase in temperature of the sample provided, however, different values of θ for the wastewater.
245

Desempenho e influência dos capins tifton 85 (Cynodon sp.) e Vetiver (Chrysopogon zizanioides) no tratamento de esgoto sanitário em sistemas alagados construídos / Performance and influence of Tifton 85 (Cynodon sp.) and vetiver (Chrysopogon zizanioides) grasses in the treatment of sanitary sewage in constructed wetlands

Jesus, Fernanda Lamede Ferreira de 24 March 2016 (has links)
Submitted by Marco Antônio de Ramos Chagas (mchagas@ufv.br) on 2016-07-12T10:44:12Z No. of bitstreams: 1 texto completo.pdf: 1615515 bytes, checksum: 9eebc016f15d949a905a93f68f2b6d3d (MD5) / Made available in DSpace on 2016-07-12T10:44:12Z (GMT). No. of bitstreams: 1 texto completo.pdf: 1615515 bytes, checksum: 9eebc016f15d949a905a93f68f2b6d3d (MD5) Previous issue date: 2016-03-24 / Fundação de Amparo à Pesquisa do Estado de Minas Gerais / No presente trabalho, procurou-se avaliar o desempenho de uma espécie de raízes fasciculadas (capim-vetiver) e outra estolonífera (capim-tifton 85), quando cultivadas em sistemas alagados construídos de escoamento horizontal subsuperficial (SAC- EHSS), no tratamento do efluente primário de esgoto sanitário. Para avaliação da influência da presença e do sistema radicular das plantas, foram utilizados três leitos, um plantado com capim-tifton 85 (SAC-EHSST), outro com capim-vetiver (SAC- EHSSV), com 12,5 propágulos por m², sendo o terceiro mantido sem plantas. Os SACs-EHSS foram construídos em paralelo, com fundo concretado e laterais em alvenaria, cobertos com lona de 2 mm de espessura. Como substrato, foi utilizada a brita gnáissica # 0, de diâmetro D60 igual a 7,0 mm, Coeficiente de Uniformidade (D60 /D10) de 1,6 e volume de vazios de 48,4 %, preenchido até a altura de 0,25 m. Cada SACs-EHSS, de área superficial de 4 m² e volume molhado (volume do substrato de preenchimento dos SACs-EHSS em contato com o esgoto sanitário em tratamento) de 1 m³, foi alimentado com vazão na faixa de 0,53 a 0,80 m³ d^-1, correspondente à de uma taxa de carregamento orgânico (TCO) de, aproximadamente, 350 kg ha^-1 d^-1 de DBO. Essa vazão proporcionou um tempo de detenção hidráulica (TDH) teórico entre 0,6 e 0,9 dias. Para avaliar o desempenho dos sistemas, foram efetuadas dez amostragens da água residuária afluente e efluente de cada SAC, no decorrer do período experimental, medindo-se a condutividade elétrica (CE), turbidez e o pH e quantificando-se as concentrações de DBO, DQO, SST, N-total, P-total, K e Na. Os valores foram corrigidos considerando-se as perdas de água por evaporação/evapotranspiração nos SACs-EHSS. Para a quantificação da produtividade de matéria seca e dos teores de N-total, P-total, K e Na no tecido vegetal, foram efetuados seis cortes da biomassa aérea das espécies vegetais cultivadas nos SACs-EHSS. No final do período de monitoramento, foram feitas escavações no meio suporte, para medição da profundidade atingida pelas raízes das plantas no substrato de preenchimento dos SACs-EHSS, além de serem quantificadas a massa e o volume ocupado pelas raízes das plantas, bem como seus teores de N-total, P-total, K e Na. De modo geral, as espécies avaliadas se adaptaram bem ao cultivo em SACs-EHSS utilizados no tratamento de esgoto sanitário, considerando- se a TCO aplicada. No substrato, foi observado maior volume, massa e profundidade das raízes do capim-vetiver, dando indícios de sua melhor adaptação e adequação a esse SAC-EHSS, comparativamente ao cultivado com o capim-tifton 85. O capim-tifton 85 mostrou-se capaz de remover mais Na em sua biomassa aérea que o capim-vetiver (p > 0,05), no entanto, em função de sua maior produtividade, houve tendência de maior remoção de N, P e K pelo capim-vetiver. A estação climática da primavera proporcionou maior remoção de nutrientes/poluentes pelas espécies vegetais avaliadas. Os SACs-EHSS cultivados e o não cultivado se mostraram eficientes na remoção da turbidez, SST, DBO, DQO e N-total o, apresentando, no entanto, relativamente baixas remoções de P, K e Na do esgoto sanitário. A unidade não cultivada apresentou desempenho semelhante (p < 0,05) à obtida nos SACs- EHSS plantados, no que se refere à remoção de DQO, N-total e K, porém foi menos eficiente que o SAC-EHSSV na retenção de SST, DBO e turbidez. Os resultados obtidos no presente trabalho indicaram que o capim-vetiver, representante do grupo de espécies vegetais de sistema fasciculado, apresentou melhor desempenho na remoção de poluentes do esgoto sanitário que o capim-tifton 85, representante de espécies estoloníferas. Possivelmente, o maior volume e alcance, em termos de profundidade, das raízes fasciculadas é que explicam as maiores remoções obtidas no SAC-EHSSV. / This study aimed to evaluate the performance of a species of fasciculate roots (grass vetiver) and other stolon root system (grass tifton 85) when cultivated in constructed wetland of horizontal subsurface flow (CW-HSSF), in the treatment of primary effluent sanitary sewage. To evaluate the influence of the presence and root system of the plants three beds were used, a planted with Tifton 85 (CW-HSSFT), another with vetiver grass (CW-HSSFV), with 12.5 propagules per m² and the third kept without plants. The CWs were constructed in parallel with bottom and of concrete and sides of masonry, covered with 2 mm thick of plastic blanket. As substrate (of filling) of the CW-HSSFs was used gravel gneissic # 0 (diameter -D60 = 7.0 mm, coefficient of uniformity D60/D10 = 1.6 and void volume of 48.4%, which was a layer of 0.25 m thick. Each CW-HSSF, having surface area of 4 m² and wet volume (volume filling substrate CW-HSSF in contact with the sewage in treatment) of 1 m³ was fed with a flow rate in the range of 0.53 to 0.80 m³ d ^-1, corresponding to an organic loading rate (OLR) of, approximately, 350 kg ha^-1 d^-1 of BOD. This flow rate provided a theoretical hydraulic retention time (HRT) between 0.6 and 0.9 days. To evaluate the performance of systems were made ten samples of wastewater influent water and effluent from each CW-HSSF, during the experimental period, to measure the electrical conductivity, turbidity and pH and quantify the concentrations of BOD, COD, TSS, total N, total P, K and Na. The values were corrected considering water losses by evaporation/evapotranspiration in CWs-HSSF. It was also done six cuts in the biomass of plant species, for the quantification of dry matter productivity and contents of total N, P, K and Na in the plant tissue. At the end of the monitoring period, excavations were made in the substrate of the CWs-HSSF, for depth measurement achieved by plant roots, quantify the mass and volume occupied by the roots, and the N-total, total-P, K and Na content. In general, the assessed species have adapted well to cultivation in CW-HSSF used to treat sanitary sewage, considering the OLR applied. In the substrate, there was a higher volume, mass and depth of fasciculate roots of vetiver grass indicates the better adaptation and adequacy of this grass, compared to the grass tifton 85 in CW-HSSF. The Tifton 85 grass proved to be able to remove more Na in its above ground biomass that vetiver grass (p > 0.05), however, due to its higher productivity, a trend towards greater removal of N, P and K by vetiver grass. The spring weather station provided greater removal of nutrients/pollutants by plant species evaluated. Cultivated CW-HSSF and uncultivated were efficient in the removal of turbidity, TSS, BOD, COD, Total-N, presenting, however, relatively low removal of P, K and Na of the sanitary sewage. The unit uncultivated showed similar performance (p < 0,05) to the CWs-HSSF planted as regards the removal of COD, total-N, and K, but was less efficient than CW-HSSFV retention TSS, BOD and turbidity. The results obtained in this study indicated that the vetiver grass, representative group of fasciculated plant species system performed that have better performance in removing sewage polluting the Tifton 85, representative of stoloniferous species. Perhaps the greatest volume and range, in terms of depth, of fasciculate roots is that explain the largest removals observed by CW-HSSFV.
246

Avaliação do potencial de reúso dos efluentes gerados nas ETES operadas pela Cagece em Fortaleza-CE / Evaluation of the reuse potential of the effluents generated in ETES operated by Cagece in Fortaleza-CE

Rollemberg, Silvio Luiz de Sousa January 2017 (has links)
ROLLEMBERG, Silvio Luiz de Sousa. Avaliação do potencial de reúso dos efluentes gerados nas ETES operadas pela Cagece em Fortaleza-CE. 2017. 93 f. Dissertação (Mestrado em Desenvolvimento e Meio Ambiente)-Universidade Federal do Ceará, Fortaleza, 2017. / Submitted by Jairo Viana (jairo@ufc.br) on 2017-10-30T16:03:20Z No. of bitstreams: 1 2017_dis_slsrollemberg.pdf: 1353791 bytes, checksum: 4c34aa79fdcf2a6db14d3302716584cd (MD5) / Approved for entry into archive by Jairo Viana (jairo@ufc.br) on 2017-10-30T16:03:35Z (GMT) No. of bitstreams: 1 2017_dis_slsrollemberg.pdf: 1353791 bytes, checksum: 4c34aa79fdcf2a6db14d3302716584cd (MD5) / Made available in DSpace on 2017-10-30T16:03:35Z (GMT). No. of bitstreams: 1 2017_dis_slsrollemberg.pdf: 1353791 bytes, checksum: 4c34aa79fdcf2a6db14d3302716584cd (MD5) Previous issue date: 2017 / Before hydric crises occurred in Fortaleza-CE, it is observed necessity of alternatives to complement of water supply, providing such a relief in the water captation of hydric bodies. This search had as goal the potential evaluation of reuse of the effluents generated in the ETES of Fortaleza operated by Cagece. To realization, were followed the steps: (a) Data survey of the ETES; (b) Analysis of reuse modalities; (c) Flow estimates of the ETES; (d) Selection of the ETES and urban reuse standards; (e) Reuse Potential; (f) Survey of Potential consumers. In view of criteria adopted in this search, it was chosen urban reuse like way of reuse of the effluents. It was watched that about 40% of the ETES studied use Decant Degester technology, even if this is not suitable to collective sewage treatment, highlighting that the same does not answer not even the standards of releasing of effluents, neither they are suitable to be used to treatment with goal reuse. It was verified that potential of flow of the ETES studied results about 3.039,95 L/s or 262.651,7 m³/day of effluent, highlighting that all effluent is released in hydric bodies, without using of no portion of this volume to reuse. To analysis and selection of the ETEs, were adopted the parameters proposed by USEPA (2004) to use of water in restrict urban irrigation, even there is a legislation about reuse of water in Ceará, 16.033/2016 law, but weren't published parameters reuse. Analyzing effluent of the ETES, it was observed that 3 (three) stations are in the A Class, that is they answer, currently, all parameters taken like reference. The volume produced in the ETES A Class was 1.207 m³/day, all this volume already could be used in restrict urban irrigation, for example: irrigation of parks, highways and etc. In relation to possible consumers, it was observed that effluents could used by EMLURB to green areas irrigation and cleaning public places of Fortaleza put a new scenario in the Ceará about reuse, observed that creation 16.033/2016 apparatus to non-potable pratices of reuse. We can to highlight that and reuse operation like studying about avaluation, implementation way water supply complement. / Diante das frequentes crises hídricas ocorridas em Fortaleza-CE, observa-se a necessidade de alternativas para o complemento do abastecimento de água, promovendo um alívio na captação de água dos corpos hídricos. Essa pesquisa teve como finalidade a avaliação do potencial de reúso dos efluentes gerados nas ETES de Fortaleza operadas pela CAGECE. Para a realização da pesquisa, foram seguidas as etapas: (a) Levantamento de dados das ETEs; (b) Análise das modalidades de Reúso; (c) Estimativa das vazões das ETEs; (d) Seleção das ETEs e dos Padrões de Reúso Urbano; (e) Potencial de Reúso (f) Levantamento de possíveis consumidores. Tendo em vista os critérios adotados nessa pesquisa, foi escolhido a modalidade do Reúso Urbano como forma de uso dos efluentes. Observou-se que cerca de 40% das ETES estudadas utilizam a tecnologia Decanto-Digestor, mesmo esta sendo inapropriada para tratamento de esgoto coletivo, ressaltando que a mesma não atende nem mesmo os padrões de lançamentos de efluentes, tampouco estão aptas a serem utilizadas para tratamento com finalidade de reúso. Verificou-se que o potencial em termos de vazões das ETES estudadas resulta em proximadamente 3.039,95 L/s ou 262.651,7 m³/dia de efluente, destaca-se que todo esse volume é lançado em corpos hídricos, sem a utilização de nenhuma parcela para reúso. Para análise e classificação dos efluentes das ETEs, foram adotados os parâmetros propostos pela USEPA (2004) para uso da água em irrigação urbana restrita, pois, embora já exista uma legislação sobre reúso no Ceará, Lei 16.033/2016, ainda não foram divulgados os parâmetros de reúso. Analisando o efluente das ETEs, observou-se que 3 (três) estações foram agrupadas na Classe A, ou seja, atendem, atualmente, a todos os parâmetros tomados como referência. O volume diário produzidos nas ETEs Classe A foi de 1.207 m³/dia, todo esse volume já poderia ser utilizado em irrigação urbana restrita, por exemplo: Irrigação de parques, canteiro de rodovias e etc. Com relação aos possíveis consumidores, observou-se que os efluentes poderiam ser utilizados pela EMLURB para irrigação de áreas verdes e limpeza de logradouros públicos de Fortaleza. Com relação à legislação sobre reúso, observase que a implantação da Lei 16.033/2016 estabelece um novo cenário no Ceará sobre reúso, criando aparato legislativo para as práticas de reúso não potável. Por fim, ressalta-se a importância da continuidade de estudos sobre a avaliação, implantação e operação do reúso como forma de complemento do abastecimento de água.
247

Comportamento de filtro plantado horizontal (wetlands construídos) no tratamento de esgoto unifamiliar

Guimarães, Tarcio Moreno Veloso de Andrade January 2013 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Ambiental, Florianópolis, 2013. / Made available in DSpace on 2014-08-06T17:52:02Z (GMT). No. of bitstreams: 1 322568.pdf: 2253344 bytes, checksum: 5d6bb5acc1500e6445c6dc50adbf7385 (MD5) Previous issue date: 2013 / Filtros plantados com escoamento horizontal subsuperficial (FHSS) são de grande interesse no tratamento de esgoto doméstico, devido à boa eficiência e aos baixos custos de implantação e manutenção. Para o dimensionamento adequado desses sistemas, é necessária uma compreensão sólida dos processos físicos e bioquímicos que se combinam para remover os poluentes. Contribuem nestes processos: solo, microrganismos, plantas e principalmente comportamento hidrodinâmico do fluido dentro do filtro. Considerando a importância da microbiota e do comportamento hidrodinâmico nos processos de tratamento de esgoto em FHSS, além da avaliação da eficiência de tratamento, foi desenvolvido um estudo microbiológico do meio filtrante e um teste com traçador químico (NaCl). É um sistema residencial (4 pessoas; 0,27 m³ dia-1), com tratamento primário em tanque séptico, seguido de um FHSS. Foram avaliados os principais parâmetros físico-químicos e biológicos do esgoto na entrada e na saída do sistema. No meio filtrante, foram avaliadas as concentrações de bactérias heterotróficas, sólidos voláteis e microrganismos visualizados por microscopia. O FHSS apresentou, ao longo de 17 meses, eficiência satisfatória, removendo, em média, 18,7 e 3,2 g m² dia-1 de DQO e sólidos suspensos, respectivamente, o que corresponde a eficiências de 80%. Com relação à microfauna avaliada no leito filtrante, os microrganismos mais abundantes foram os ciliados, seguidos por nematoides. A concentração de microrganismos foi correlacionada positivamente com a concentração de matéria orgânica e de oxigênio. No teste com traçador foi obtida uma eficiência volumétrica de 1,14 e um tempo de detenção hidráulico médio de aproximadamente 5 dias. Foi obtido um valor de 0,02 para o número de dispersão (d). Os valores obtidos para os coeficientes de cinética de primeira ordem de remoção de DQO, para os modelos clássicos aplicados aos dados do FHSS foram de 0,35 ? 0,44 d-1. Estes dados contribuem para o dimensionamento de filtros plantados, preenchidos com areia, aplicados em escala residencial para o tratamento de esgotos. <br>
248

Estudo do comportamento da DBO em suporte aeróbio de oxigênio puro: coeficientes cinéticos e fatores de correlação / I study of the behavior of DBO in support aerobic of pure oxygen: kinetic coefficients and correlation factors

Barbosa, João Marcelo do Nascimento January 2003 (has links)
Made available in DSpace on 2012-09-06T01:11:30Z (GMT). No. of bitstreams: 2 license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) 598.pdf: 9014270 bytes, checksum: 50ddc5b9b9f3b1a57694ee2b65989074 (MD5) Previous issue date: 2003 / Os sistemas de tratamento de esgotos por lodos ativados, utilizando como suporte aeróbio o oxigênio puro, vem sendo utilizados cada vez com maior freqüência no tratamento de efluentes industriais e, recentemente, no tratamento de esgotos domésticos. No dimensionamento destes sistemas de tratamento tem sido utilizada uma DBO, que utiliza oxigênio puro como suporte aeróbio, que reflete de forma mais realista a eficiência destes sistemas na remoção da matéria orgânica biodegradável. Apesar da grande importância desta DBO modificada não há referências na literatura sobre a sua cinética. Neste trabalho foi estudada a diferença entre os coeficientes cinéticos e os graus de eficiência na remoção da matéria orgânica biodegradável, de um sistema que utilize para análise de DBO um suporte aeróbio tradicional (DBOt), e de outro que utilize oxigênio puro como suporte aeróbio (DBOm). A metodologia operacional desta pesquisa foi baseada na realização de análises para avaliação do comportamento da DBO, quando em meio de ar atmosférico ou em meio de oxigênio puro através da incubação por cinco dias a 20oC e com leitura de oxigênio dissolvido, realizada diariamente, pelo método Winkler. Os resultados das análise demonstraram significativa diferença entre os valores da DBOt e da DBOm, foi obtido um fator de correlação da razão DBOm/DBOt de 1,523 mais ou menos 0,103, demonstrando um aumento da eficiência na remoção da matéria orgânica de cerca de 50 por cento, pelo uso do oxigênio nas condições do ensaio. Através destes resultados obtidos, foram calculados os coeficientes cinéticos (K) associados à redução da DBO; tanto tradicional (DBOt) quanto modificada (DBOm). Além dos aspectos técnicos dos sistemas de tratamento com oxigênio puro, descritos sucintamente neste trabalho, foi realizada uma investigação das aplicações destes sistemas no Brasil, com ênfase em sua evolução histórica entre as décadas de oitenta e noventa. Nesta pesquisa, de cunho mercadológico, da evolução histórica desta técnica de tratamento, foi realizada uma pesquisa de campo com entrevistas aos gerentes de marketing das empresas que fabricam sistemas de aeração com oxigênio puro para tratamento de efluentes. Como resultado desta investigação, é apresentado no capítulo três um consolidado de caráter qualitativo.
249

Viabilidade do uso de efluentes tratados por zona de raízes na irrigação: estudo de caso na Vila Dois Rios - Ilha Grande, RJ / Constructed of the use of efluente treated by try to use it in irrigation: case study in the Vila Dois Rios - Ilha Grande, RJ

Kaczala, Fábio January 2005 (has links)
Made available in DSpace on 2012-09-06T01:12:43Z (GMT). No. of bitstreams: 2 license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) 830.pdf: 2200736 bytes, checksum: 944e99d433e4bb3d4d9dc05ec86761f1 (MD5) Previous issue date: 2005 / A escassez de água doce, atualmente está gerando diversos tipos de problemas, devido aos usos múltiplos e demanda crescente, principalmente para as necessidades fisiológicas humanas, e atividades econômicas como a indústria, e a irrigação para produção de alimentos. Os países mais atingidos por esta escassez buscam alternativas de. Uma destas alternativas são as águas residuárias tratadas. Atualmente a atividade humana que representa o maior consumo de água é a irrigação, o que a torna a atividade com maior necessidade de recursos alternativos. O uso de águas residuárias para a irrigação, requer uma qualidade microbiológica e físico-química que não traga riscos ao meio ambiente e principalmente à saúde pública. O presente trabalho teve como objetivo analisar a qualidade microbiológica e físico-química do efluente de um sistema de tratamento biológico de esgotos domésticos de pequeno gerador utilizando o processo de Zona de Raízes como polimento final, e a viabilidade de utilizá-lo para a irrigação de acordo com algumas diretrizes existentes para proteção à saúde pública. Foram analisados alguns parâmetros, sendo que os de maior importância para a saúde pública foram os parâmetros biológicos Escherichia coli e ovos de Helmintos, além do indicador coliforme totais. O sistema foi analisado em um período de 6 meses e demonstrou viabilidade para a aplicação e utilização do efluente na irrigação, principalmente para fins de culturas industrialmente processadas, silvicultura, plantas forrageiras, culturas frutíferas arbóreas e também de cereais.
250

Avaliação do atual potencial de reúso de água no Estado do Ceará e propostas para um sistema de gestão / The current assessment of potential water reuse in the state of Ceará and proposals for a management system

Caixeta, Cláudia Elizângela Tolentino 25 January 2010 (has links)
CAIXETA, C. E. T. Avaliação do atual potencial de reúso de água no Estado do Ceará e propostas para um sistema de gestão. 2010. 324 f. Tese (Doutorado em Engenharia Civil: Saneamento Ambiental) – Centro de Tecnologia, Universidade Federal do Ceará, Fortaleza, 2010. / Submitted by João silva (jpauloqxb@gmail.com) on 2016-04-25T18:03:51Z No. of bitstreams: 1 2010_tese_cetcaixeta.pdf: 6903861 bytes, checksum: 2a9af853a33fcc0441f79d99565d008b (MD5) / Approved for entry into archive by Marlene Sousa (mmarlene@ufc.br) on 2016-04-29T17:14:37Z (GMT) No. of bitstreams: 1 2010_tese_cetcaixeta.pdf: 6903861 bytes, checksum: 2a9af853a33fcc0441f79d99565d008b (MD5) / Made available in DSpace on 2016-04-29T17:14:37Z (GMT). No. of bitstreams: 1 2010_tese_cetcaixeta.pdf: 6903861 bytes, checksum: 2a9af853a33fcc0441f79d99565d008b (MD5) Previous issue date: 2010-01-25 / The main objective of this work was evaluate the potential for water reuse in the state of Ceara as a contribution to the effective management of water resources and the conservation of the state. It consisted of the following stages: (1) literature, (2) A bibliographical survey; (2) description of the Ceara State (area under study); (3) definition of alternatives and criteria for reuse, (4) survey of treatment plants with respective flow rates and characteristics of treatment system for selection of those whose effluent can be used, (5) proposition (s) type (s) to reuse the selected treatment plants, (6) economic feasibility study for the financial reuse industrial (7) conditions of proposition and guidelines for the strengthening of reuse in the State, (8) present and discuss the results and (9) assessing the work undertaken. As results of the study we can mention: (1) The industrial reuse was feasible to be deployed in DI Maracanaú, and the effluent standard type 2 (effluent from the stabilization pond, mixing tank for pH correction, flocculant, decantor, carbonation tank and final effluent) showed the best economic and financial viability. (2) Research conducted with companies in the DI Maracanaú showed great responsiveness on the part of potential users, since it is guaranteed quality, quantity and price competitive with current power supply. (3) Of the 12 systems evaluated the Tupamirim WTPT presented the best conditions for the practice of non-potable urban reuse - irrigation of green areas in Fortaleza (4) The system of stabilization ponds in operation in the RMF and the State can provide a flow of about 1872.0 L / s, and these volumes will benefit approximately 3279.66 hectares, whereas the demand for irrigation equal to18,000 m3/ha.ano, or supply, on average, a growing area of 1,497,600 m2 fish (149.7 ha). The main conclusions of this work are: (1) The implementation of water reuse in Ceará is an important alternative to be considered in the State Plan for Water Resources, as it may: contribute effectively in the conservation of water resources, increase the supply of water for agricultural, fish and industry in the state, through the provision of reclaimed water for uses that can dispense the drinking, and provide a greater volume of water of good quality to end uses, as recommended by Agenda 21.(2) Among the types of reuse study for the state, all proved viable. As the industrial reuse which will require a larger investment. Since the re-use agricultural and fish are the easiest to implement, requiring only a determination of the State Government so that it signed a partnership betweean Cagece and SDA thus enable the implementation of projects.(3) The reuse of wastewater in the state of Ceara is a viable alternative, but necessary regulations to mitigate the pest risk that may arise from the practice without the adoption of multiple barriers to ensure protection of population health. Is no denying the need to establish guidelines that allow the practice of reuse to become secure, ubiquitous, thus helping to minimize the problem of water scarcity in the state. / Este trabalho teve como objetivo avaliar o potencial de reúso de águas no Estado do Ceará como forma de contribuir para o efetivo gerenciamento dos recursos hídricos e para a conservação ambiental do Estado. O trabalho foi desenvolvido observando as seguintes etapas: (1) levantamento bibliográfico; (2) caracterização do Estado do Ceará (área de estudo); (3) definição das alternativas e critérios de reúso; (4) levantamento das ETEs com respectivas vazões e as características do sistema de tratamento para seleção daquelas cujos efluentes podem ser utilizados; (5) proposição do(s) tipo(s) de reúso para as ETEs selecionadas; (6) estudo de viabilidade econômica financeira para o reúso industrial; (7) proposição de condições e diretrizes para o fortalecimento do reúso no Estado; (8) apresentar e discutir os resultados; (9) avaliar o trabalho desenvolvido. O trabalho tem como resultados: (1) O reúso industrial mostrou-se viável para ser implantado no Distrito Industrial (DI) de Maracanaú, sendo que o efluente do tipo Padrão 2 (efluente da lagoa de estabilização, tanque de mistura para correção do pH, floculador, decantor tanque de recarbonatação e efluente final) foi o que apresentou melhor viabilidade econômico financeira. (2) Pesquisa realizada junto às empresas do DI de Maracanáu evidenciou grande receptividade por parte dos usuários potenciais, desde que sejam garantidos qualidade, quantidade e preço competitivo com a atual fonte de abastecimento.(3) Dos 12 sistemas avaliados, a ETE Tupamrim foi a que apresentou condições mais adequadas para a prática do reúso urbano não potável – rega de áreas verdes de Fortaleza. (4) Os sistemas de lagoas de estabilização em operação na RMF e interior do Estado podem disponibilizar uma vazão de cerca de 1.872,0 L/s, e tais volumes poderão beneficiar cerca de 3.279,66 hectares, considerando uma demanda para irrigação igual a 18.000 m3/ha.ano; ou suprir, em média, uma área de cultivo de peixes de 1.497.600 m2 (149,7 ha). Com base nos resultados pode-se concluir: (1) A implementação de reúso de água no Ceará é uma alternativa importante a ser considerada no Plano Estadual de Recursos Hídricos, pois poderá: contribuir efetivamente na preservação dos recursos hídricos; aumentar a oferta de água para os setores agrícola, piscícola e industrial no Estado, por meio da disponibilização da água recuperada aos usos que possam prescindir de potabilidade; e disponibilizar um volume maior de água de boa qualidade aos usos nobres, conforme preconiza a Agenda 21. (2) Dentre as modalidades de reúso estudadas para o Estado, todas se mostraram viáveis, sendo o reúso industrial o que vai necessitar de um maior investimento. Já os reúso agrícola e em piscicultura são os mais fáceis de serem implementados, necessitando apenas de uma determinação do Governo do Estado para que seja firmada uma parceria entre Cagece e SDA e, dessa forma, viabilizar a implantação dos projetos. (3) O reúso de águas residuárias no Estado do Ceará é uma alternativa viável, desde que haja uma regulamentação para minimizar os riscos epidemiológicos que podem advir da prática sem a adoção de barreiras múltiplas para garantir a proteção da saúde populacional. É incontestável a necessidade do estabelecimento de diretrizes que permitam que a prática do reúso se torne segura e difundida, contribuindo assim para a minimização do problema de escassez de água no Estado.

Page generated in 0.056 seconds