• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 13
  • Tagged with
  • 15
  • 15
  • 9
  • 6
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Cultivo de milho irrigado com esgoto doméstico tratado no semiárido baiano: alternativa técnica e econômica para o pequeno agricultor

Silva, Luana Tavares 03 August 2015 (has links)
Submitted by LIVIA FREITAS (livia.freitas@ufba.br) on 2016-06-13T18:40:24Z No. of bitstreams: 1 TEMPLATE DISSERTAÇÃO FINAL LUANA. PDF.pdf: 2543206 bytes, checksum: 963a12e40f43d5e896e53f12b5a21987 (MD5) / Approved for entry into archive by LIVIA FREITAS (livia.freitas@ufba.br) on 2016-06-20T16:23:34Z (GMT) No. of bitstreams: 1 TEMPLATE DISSERTAÇÃO FINAL LUANA. PDF.pdf: 2543206 bytes, checksum: 963a12e40f43d5e896e53f12b5a21987 (MD5) / Made available in DSpace on 2016-06-20T16:23:34Z (GMT). No. of bitstreams: 1 TEMPLATE DISSERTAÇÃO FINAL LUANA. PDF.pdf: 2543206 bytes, checksum: 963a12e40f43d5e896e53f12b5a21987 (MD5) / O objetivo da pesquisa foi determinar a viabilidade técnica e econômica do cultivo de milho irrigado com esgoto doméstico tratado para o pequeno agricultor em São Domingos localizada no semiárido baiano. Para isso investigou-se os parâmetros de produção do milho cultivado mediante aplicação de esgoto doméstico tratado com diferentes lâminas de água a partir da evaporação do tanque classe A e posterior avaliação da produção e possível viabilidade econômica de cultivo em escala real. A primeira fase da pesquisa foi desenvolvida em casa de vegetação construída em campo, no município de São Domingos-BA. O trabalho foi realizado em escala experimental utilizando delineamento inteiramente casualizado em esquema fatorial 5X4 com 4 repetições, totalizando 80 unidades experimentais compostas por vasos de 60L, com cinco sementes de milho cultivar catingueiro em cada vaso inicialmente. Os tratamentos foram compostos por cinco níveis de diluição do efluente com água de abastecimento nas porcentagens de: 0, 25, 50, 75 e 100%, além das lâminas aplicadas nas percentagens de 60, 90, 120 e 150% da evaporação do tanque classe A. Foram mensurados os parâmetros para avaliação do desenvolvimento da planta, concluindo que as diluições do esgoto com 75 e 100% e lâminas de 120% produziram melhores resposta nas avaliações dos parâmetros de produção. A segunda fase da pesquisa foi desenvolvida em área adjacente a casa de vegetação. Foi montado um sistema de irrigação por gotejamento em área de 200m² utilizando 100% de esgoto doméstico para irrigação da cultura, realizando análises apenas da fase reprodutiva do ciclo, comprimento, diâmetro, peso de espigas, além de massa fresca da parte aérea além disso foi feito o levantamento dos custos de produção da safra para posterior análise de custo benefício da proposta de cultivo. De modo geral o uso do efluente viabilizou a produção em escala experimental e real com tendência a promover um desenvolvimento superior quando comparado com uso de água de abastecimento
2

Ozonização como pós-tratamento de efluente de esgoto doméstico

Camilo Júnior, Osli Barreto 22 February 2018 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Agronomia e Medicina Veterinária, Programa de Pós-Graduação em Agronomia, 2018. / Submitted by Fabiana Santos (fabianacamargo@bce.unb.br) on 2018-08-20T19:43:11Z No. of bitstreams: 1 2018_OsliBarretoCamiloJúnior.pdf: 1184807 bytes, checksum: b209ead832966f07a75cb8760bfbb64e (MD5) / Approved for entry into archive by Raquel Viana (raquelviana@bce.unb.br) on 2018-08-20T20:17:50Z (GMT) No. of bitstreams: 1 2018_OsliBarretoCamiloJúnior.pdf: 1184807 bytes, checksum: b209ead832966f07a75cb8760bfbb64e (MD5) / Made available in DSpace on 2018-08-20T20:17:50Z (GMT). No. of bitstreams: 1 2018_OsliBarretoCamiloJúnior.pdf: 1184807 bytes, checksum: b209ead832966f07a75cb8760bfbb64e (MD5) Previous issue date: 2018-08-20 / Dentre as várias opções de tratamento secundário de esgoto, o uso de tanques sépticos seguidos do Sistema de Zona de Raízes (SZR) apresentam características favoráveis, como eficiente remoção de microrganismos, sais e compostos tóxicos. Entretanto, persistem atributos como a cor, turbidez, dentre outros que podem ser reduzidos com tratamento terciário, como a ozonização. Diante do exposto, o objetivo deste trabalho foi avaliar a aplicação da ozonização em efluente de esgotos doméstico tratado em tanques sépticos em série seguidos de SZR. Foram aplicados os tempos de exposição ao ozônio de 0, 30, 60, 90, 120 e 150 min. na dosagem constante de 12 mg L-1 de O3, bem como dosagens de 0, 4, 10, 17, 25 e 35 mg L-1 de O3 durante tempo de exposição de 30 min. Em todos os ensaios, a vazão de ozônio foi ajustada em 1 L min.-1. Foram realizadas sete campanhas de coleta de efluente de diferente composição, sendo que em cada amostra foi analisado o Potencial Hidrogeônico (pH); Condutividade Elétrica (CE), Demanda Química de Oxigênio (DQO), Demanda Bioquímica de Oxigênio (DBO), Oxigênio Dissolvido (OD) Alcalinidade Total (Atotal), Sódio (Na+), Potássio (K+), Amônia (NH3), Turbidez, Cor, Escheria coli, Coliformes Totais, Sólidos Suspensos, Sólidos Dissolvidos e Sólidos Totais. A ozonização promoveu redução significativa de cor e turbidez do efluente até o tempo de 120 min de exposição na dosagem de 12 mg L-1 de O3 e até a concentração de 17 mg L-1 de O3 por 30 min. A condutividade elétrica reduziu 7,0% no tempo de esposição de 120 min. sendo que, de maneira geral, o tempo de exposição é mais efetivo na alteração da CE do que o aumento na dosagem de ozônio. O pH se elevou 12,30% no tempo de 120 e 150 min. e 9,4% na dosagem de 4 mg L-1 de O3; já a alcalinidade se elevou 22,2% na dosagem de 17 mg L-1 de O3 e oxigênio dissolvido de 351% no tempo de 90 min. e 424% na dosagem de 17 mg L-1 de O3. A ozonização não promoveu alterações nos teores de potássio, sódio, amônia, sólidos suspensos, sólidos dissolvidos e sólidos totais. A Escheria coli, coliformes totais, DQO e DBO não apresentaram correlação consistente entre os diferentes tempos de exposição e dosagens de ozônio. / There are several options to treat sewage and the use of septic tanks and the Root Zone System (RZS) presents valuable characteristics, as the remotion of microorganisms, salts and toxic compounds. However, there are persistent attributes such as color, turbidity, among others that can be removed with tertiary treatment, such as ozonization. In view of the above, the objective of this work was to evaluate the application of ozonation in treated domestic sewage effluent in septic tanks in series. Exposure times of 0, 30, 60, 90, 120 and 150 min were applied in the constant dosage of 12 mg L-1 of O3, as well as dosages of 0, 4, 10, 17, 25 and 35 mg L-1 of O3 during the exposure time of 30 min. In all tests, the ozone flow rate was adjusted to 1 L min -1. Seven campaigns of collection of different effluent composition were carried out. In each sample of effluent were analyzed the Potention Hydrogen (pH), Electrical Conductivity (EC), Chemical Oxygen Demand (COD), Biochemical Oxygen Demand (BOD), Dissolved Oxygen (DO), Total Alkalinity (totalA), Sodium (Na+), Potassium (K+), Ammonia (NH3), Turbidity, Color, Escheria coli, Total Coliforms, Suspended Solids, Dissolved Solids and Total Solids. At the exposure time of 120 min and 17 mg L-1 of O3, there was reduction of turbidity of 40.6% and 58.9%; color reduction of 76.2% and 81.5%; and reduction of the electrical conductivity of 7.0% in the time of 120 min. The pH increased by 12.30% in the time of 120 and 150 min and 9.4% in the dosage of 4 mg L-1 of O3; Alkalinity rose 22.2% at the dose of 17 mg L-1 of O3 and dissolved oxygen of 351% at 90 min of exposure and 424% at the dose of 17 mg L-1 of O3. The ozonization does not promote any changes in the contents of potassium, sodium, ammonia, suspended solids, dissolved solids and total solids. E. coli, Total Coliforms, Chemical Oxygen Demand (COD) and Biochemical Oxygen Demand (BOD) did not present a consistent relation between the exposure time and the ozon doses.
3

Avaliação de um Wetland construído no tratamento de efluentes sépticos: estudo de caso Ilha Grande, Rio de Janeiro, Brasil / Performance of a constructed Wetland in treating septics effluents: case study Ilha Grande, Rio de Janeiro, Brazil

Toniato, João Vitor January 2005 (has links)
Made available in DSpace on 2012-09-06T01:10:56Z (GMT). No. of bitstreams: 2 license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) 826.pdf: 859257 bytes, checksum: 37e07b951bdc6d6335a2ecbb6e5677e0 (MD5) Previous issue date: 2005 / Os atuais níveis de atendimento dos serviços de saneamento no Brasil, principalmente a disposição segura dos esgotos, têm levado grande parte da população à condições de saúde abaixo de um nível adequado. A solução para estes problemas passa necessariamente pela implementação de sistemas de tratamento adequados à realidade do país, ou seja, baratos e de simples operação e manutenção. A técnica aqui avaliada, de wetlands construídos, se enquadra nestes requisitos e mostrou bons resultados durante o período de monitoramento. A metodologia foi baseada na análise da eficiência, através de parâmetros físico-químicos e microbiológicos de qualidade de água, de um sistema de wetland construído de fluxo subsuperficial tratando esgoto séptico de um centro de pesquisa localizado na Ilha Grande, sudoeste do Estado do Rio de Janeiro. Os resultados mostraram remoções satisfatórias para DQO (29 - 87 por cento); DBO (44 - 88 por cento); turdidez (73 95 por cento); e ovos de helmintos (ausência em todos amostras para o efluente), mas insatisfatórios para fósforo(-7 31 por cento) e indicadores microbiológicos, coliformes totais (72 99,86 por cento) e Escherichia coli (69 99,98 por cento). O suprimento de oxigênio para o meio mostrou-se insuficiente ou mal distribuído, ocasionando baixa taxa de nitrificação e conseqüentemente pouca remoção para NTK (17 33 por cento) e NH3 (0 73 por cento). Todavia, a grande perda líquida do esgoto pela evapotranspiração reduziu em muito a vazão na saída do tratamento, e ofereceu um descarte seguro para o corpo receptor. De acordo com estes resultados, sistemas wetlands construídos se constituem como boas opções para o tratamento de esgotos domésticos, mas necessitando de uma processo de desinfecção posterior para assegurar condições de descarte que não ofereçam riscos de contaminação fecal.
4

Tecnologias sociais e ecológicas aplicadas ao tratamento de esgotos no Brasil / Social and environmental technologies applied to sewage treatment in Brazil

Fonseca, Alexandre Ribeiro January 2008 (has links)
Made available in DSpace on 2012-09-06T01:12:33Z (GMT). No. of bitstreams: 2 license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) 1062.pdf: 3022315 bytes, checksum: c488d58ba548ba30c3f406c47c93989f (MD5) Previous issue date: 2008 / Nesta dissertação, buscou-se evidenciar o papel do Estado na formulação de políticas públicas para a área saneamento, sendo determinante na escolha do padrão tecnológico para a concepção dos projetos de sistemas de tratamento dos esgotos domésticos. Fez-se uma reflexão e chegou-se a hipótese que as opções tecnológicas para tratamento de esgotos domésticos estão relacionadas a interesses de forças políticas, que ditam o controle e o nível de implementação de projetos, que através de mecanismos legais e de mercado, dificulta-se o controle social. O interesse por esse assunto parte do entendimento de que as tecnologias para o tratamento de esgotos domésticos, por serem uma decisão destinada a satisfação de vários grupos com interesses heterogêneos poderão ser melhor formuladas e implementadas mediante negociações com as partes protagonistas, tendo como componentes básicos a sustenilidade ambiental e o controle social. Procedeu-se uma análise global e das alternativas possíveis sobre as visões, as teorias e os modelos discutidos, que implicassem em mudanças no padrão tecnológico tradicional. Conseqüentemente, um número muito reduzido de alternativas foi considerado, sendo avaliado para cada alternativa um número restrito de conseqüências importantes. Para tornar o problema mais manejável, procurou-se distinguir as características das tecnologias, com ênfase nos conceitos de Tecnologias Sociais e Ecológicas, pois se acredita que encetam componentes básicos das mudanças para que os processos de tomada de decisão se tornem mais transparentes e abertos ao protagonismo social. Devido a essas limitações não se pode precisar, categoricamente, se as decisões são boas ou más, tendo em vista a problemática levantada, esses esforços podem servir como um paliativo para as imperfeições sociais existentes por serem mais coletivos e por buscarem a promoção ou tentativas de sustenilidade econômica e ambiental.
5

Avaliação do tratamento combinado de lixiviado de aterros de resíduos sólidos urbanos e esgoto doméstico utilizando indicadores físico-químicos e biológicos / Evaluation of the combined treatment of landfill leachate from municipal solid waste and sewage indicators using physicochemical and biological

Mannarino, Camille Ferreira January 2010 (has links)
Made available in DSpace on 2016-02-26T13:26:06Z (GMT). No. of bitstreams: 2 759.pdf: 2298604 bytes, checksum: 1d83ddf201b23c425405d997938a58ad (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2010 / O tratamento e disposição de lixiviados de aterros de resíduos sólidos urbanos é um grande problema ambiental, com impactos sobre a saúde das populações que vivem em áreas circunvizinhas aos aterros, devido às características poluentes dos lixiviados. Uma solução adotada em muitos países é o tratamento combinado de lixiviado e esgoto doméstico em estações de tratamento de esgotos (ETE). A viabilidade dessa opção depende da capacidade da estação de tratamento em assimilar as cargas, sobretudo orgânica e nitrogenada, advindas do lixiviado. No presente trabalho, buscou-se avaliar a eficiência do tratamento combinado de lixiviado e esgoto doméstico por meio de indicadores biológicos de toxicidade aguda e sub-crônica e não somente por parâmetros físico-químicos de controle de poluição. Foi monitorado o tratamento do lixiviado do aterro do Morro do Céu combinado com esgoto doméstico na ETE Icaraí (Niterói RJ) e em uma estação de tratamento em escala piloto. Os ensaios ecotoxicológicos agudos, realizados com peixes Danio rerio e microcrustáceos Daphnia similis, mostraram que, embora o lixiviado seja muito mais tóxico a esses organismos do que o esgoto, a mistura do lixiviado ao esgoto não resultou em um afluente ao tratamento mais tóxico do que o esgoto puro. Após o tratamento, o efluente da estação apresentou toxicidade a peixes reduzida em relação ao afluente da mesma e abaixo do limite estabelecido pela legislação ambiental. Não houve redução significativa de toxicidade a microcrustáceos no tratamento empregado na ETE. / Biomarcadores indicadores de toxicidade sub-letal foram avaliados em peixes do tipo Tilápia. A concentração de Metalotioneínas não indicou maior presença de metais nos peixes expostos do que nos controles. A atividade da enzima Acetilcolinesterase foi inibida em apenas um dos grupos expostos, indicando possível presença de agrotóxicos organofosforados e/ou carbamatos no efluente tratado. Os HPA s utilizados como biomarcadores (Naftaleno, Pireno, Benzo(a)pireno e 1-Hidroxipireno) indicaram que os peixes expostos tiveram maior absorção de HPA s do que os peixes controles, sinalizando a provável presença desses compostos em ao menos um dos afluentes ao tratamento combinado. As frequências de Micronúcleos e outras anormalidade nucleares eritrocitárias também apontaram para maiores danos genotóxicos em células de organismos expostos do que nos controles.
6

Influência nos atributos da água e do solo e no nível do lençol freático após lançamento de efluente em valas de infiltração

Cruz Magaña, Jazmin Del Carmen de 27 July 2016 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Agronomia e Medicina Veterinária, 2016. / Submitted by Fernanda Percia França (fernandafranca@bce.unb.br) on 2016-09-20T18:04:00Z No. of bitstreams: 1 2016_JazmindelCarmendeLaCruzMagaña.pdf: 2027630 bytes, checksum: 7c93697c319b3e52708a05d3c012a220 (MD5) / Approved for entry into archive by Raquel Viana(raquelviana@bce.unb.br) on 2016-11-01T16:24:45Z (GMT) No. of bitstreams: 1 2016_JazmindelCarmendeLaCruzMagaña.pdf: 2027630 bytes, checksum: 7c93697c319b3e52708a05d3c012a220 (MD5) / Made available in DSpace on 2016-11-01T16:24:45Z (GMT). No. of bitstreams: 1 2016_JazmindelCarmendeLaCruzMagaña.pdf: 2027630 bytes, checksum: 7c93697c319b3e52708a05d3c012a220 (MD5) / A disposição de efluente tratados em valas de infiltração é uma alternativa viável em substituição ao lançamento de efluente diretamente em cursos de água superficiais, onde o solo funciona como meio filtrante e favorece a recarga do lençol freático, por outro lado, pode interferir na composição química da água e do solo. O objetivo foi avaliar o funcionamento de valas de infiltração que recebem efluente de esgoto doméstico tratado por três tanques sépticos em série, seguidos de leitos cultivados dispostos em paralelo, cultivados com diferentes espécies de macrófitas emergentes. Mediu-se a variação no nível do lençol freático, interferência em atributos físicos, químicos e microbiológicos na água coletada em poços de observação e nos atributos químicos do solo sob as valas de infiltração nas camadas de 0 a 0,20 m e 0,20 a 0,40 m. Foram construídas 6 valas de infiltração com nove metros comprimento cada uma e 1 m de largura superficial e 0,88 m de largura de fundo. Perfurou-se 11 poços de observação em diferentes posições em relação ao local de implantação das valas de infiltração. O período compreendeu de setembro 2015 a junho 2016, com coletas de amostras de água mensais. O lançamento de efluente nas valas de infiltração não interfere no nível de água do lençol freático. O nitrato, amônia, fosfato total, sólidos totais e DBO apresentam tendência de elevação no poço de observação localizado até 2,5 m de afastamento das valas. O teor de ferro, manganês, cálcio e magnésio apresentam elevação no solo no final do experimento em relação ao seu início. _________________________________________________________________________________________________ ABSTRACT / The disposal treated effluents in swales is a viable alternative to launch directly into surface water, where the soil works as filter media and promotes groundwater recharge, on the other hand, this can influence in the composition of the water. This study aims to evaluate the swales operation that receives sewage treated for three septic tanks in series, followed by construct wetlands arranged in parallel, planted with different species of emergent macrophytes. The variation of the groundwater level was evaluated, the interference in physical, chemical and microbiological attributes in water collected from observation wells and chemical soil under the swales in layers up 0 to 0.20 m 0.20 to 0.40 m. Six infiltration rafts were constructed with nine meters in length and 1.0 m wide and 0.88 m surface of bottom width. Eleven observation wells were drill with 4 m deep on average in different positions in relation to the siting of swales. The period of evaluation was from September 2015 to June 2016 with monthly water samples. The parameters of behavior were: nitrates, ammonia, total of phosphate, total of solids, DBO and the E. colli had a tendency to present higher values in wells that were near the sewage infiltration area. As for the quality of the soil in the layer 0 to 0.20 m can observe significant changes in the quality of soil trenches, increases with iron, manganese, calcium and magnesium in the last example of the experiment from the beginning.
7

Avaliaçao de um sistema hibrido integrado de lodo ativado e biofilme em leito móvel para tratamento de esgotos domésticos, utilizando PVA-Gel como meio suporte / Evaluation of an hybrid system integrated of activated sludge and biofilm in moving bed for domestic sewage treatment, using PVA-Gel as a carrier

Mota, Ana Maria do Carmo 07 July 2015 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Civil e Ambiental, 2015. / Submitted by Raquel Viana (raquelviana@bce.unb.br) on 2015-11-06T19:16:12Z No. of bitstreams: 1 2015_AnaMariadoCarmoMota.pdf: 4808251 bytes, checksum: f4d668ffe64f49dd5f289b4c38732d77 (MD5) / Approved for entry into archive by Marília Freitas(marilia@bce.unb.br) on 2015-12-20T16:07:36Z (GMT) No. of bitstreams: 1 2015_AnaMariadoCarmoMota.pdf: 4808251 bytes, checksum: f4d668ffe64f49dd5f289b4c38732d77 (MD5) / Made available in DSpace on 2015-12-20T16:07:36Z (GMT). No. of bitstreams: 1 2015_AnaMariadoCarmoMota.pdf: 4808251 bytes, checksum: f4d668ffe64f49dd5f289b4c38732d77 (MD5) / O sistema de lodos ativados é um dos processos de tratamento de águas residuárias mais utilizados no mundo. Apesar de apresentar boas eficiências na remoção de matéria orgânica e nutrientes, é muito sensível a aumento de cargas hidráulicas e orgânicas, além de gerar grandes quantidades de lodo. Vários estudos indicam que a implantação de sistemas híbridos pode resultar na otimização das vantagens e minimização das desvantagens do sistema de lodos ativados. O IFAS (Integrated Fixed-Film activated Sludge) é a um sistema de tratamento biológico formado pela associação do sistema de lodos ativados ao sistema MBBR (Moving Bed Biofilm Reactor), no qual a biomassa cresce aderida a meios suporte mantidos em suspensão nos reatores biológicos. O presente estudo teve como objetivo avaliar o comportamento de uma unidade piloto, utilizando o sistema IFAS, em diferentes tempos de detenção hidráulica (TDH). Foi utilizado o PVA-Gel como meio suporte para crescimento da biomassa. Trata-se de um hidrogel poroso, que possui uma estrutura de malha com poros minúsculos, produzido a partir de álcool polivinílico, com densidade específica de 1.025, taxa de absorção de água de 0,08 m3/m3 e área superficial total de 2500m2/m3. A unidade piloto foi instalada na ETE Riacho Fundo, uma das unidades de tratamento de esgotos da Companhia de Saneamento Ambiental do Distrito Federal (CAESB). O sistema foi operado com sete regimes operacionais diferentes, nos quais foram aplicados TDHs que variaram de 18 a 5,1 horas e carga de amônia de 41 a 230 g N-NH4+. m-3.d-1. A eficiência de remoção global de nitrogênio amoniacal foi de 79%, sendo que nos regimes com TDH de 18,12 e 9 horas, essa eficiência se manteve acima de 90%. Verificou-se pouca variação na eficiência de remoção de matéria orgânica ao longo do experimento, mantendo uma eficiência média de 95% de remoção de DQO solúvel. A estrutura da comunidade de protozoários e metazoários foi semelhante àquela observada nos sistemas de lodos ativados. Ensaios de atividade específica indicaram que a biomassa imobilizada no PVA-Gel é eficiente na remoção de amônia e matéria orgânica, com uma taxa de oxidação de amônia de até 12 mg N-NH4+h-1 em 0,525L de PVA-Gel. ______________________________________________________________________________________________ ABSTRACT / The activated sludge system is one of sewage treatment process most commonly used in the world. Despite showing good efficiency in removing organic matter and nutrients, it is very sensitive to increased hydraulic and organic loads, besides generate large amounts of sludge. Several studies indicate that the deployment of hybrid systems can result in optimizing the advantages and minimizing the disadvantages of activated sludge system. The IFAS (Integrated Fixed-Film Activated Sludge) is a biological treatment system formed by the combination of activated sludge system to the MBBR (Moving Bed Biofilm Reactor) in which the biomass grows attached to support means maintained in suspension in the biological reactor. This study aimed to evaluate the behavior of a pilot plant using the IFAS system at different hydraulic retention times (HRT). PVA-Gel was used as a carrier to the biomass growing. This is a porous hydrogel which has a knitted structure with small pores, produced from polyvinyl alcohol with a specific gravity of 1.025, water absorption rate of 0.08 m3 / m3, and the specific surface area of 2500m2. m-3. The pilot unit was installed in the Sewage Treatment Plant Riacho Fundo, one of the sewage treatment units of Environmental Sanitation Company of the Federal District. The system was operated at seven different operational systems, which were applied HRT ranging from 18 to 5.1 hours, ammonia load of 41 - 230 g N-NH4 +. m- 3.d -1. The overall removal efficiency of ammonia was 79%, and in HRT regimens of 18,12 and 9 hours, this efficiency has remained above 90%. There was little variation in the organic matter removal efficiency throughout the experiment, maintaining an average efficiency of 95% removal of soluble COD. The structure of the protozoa and metazoan community was similar to that observed in activated sludge systems. Specific activity assays indicated that the biomass immobilized in PVA-gel is effective in removing organic matter and ammonia to an ammonia oxidation rate of up to 12 mg N-NH4 + h-1 in 0,525L PVA- Gel.
8

Propriedade das normas de lançamento de esgoto / Properties of the norms of sewer release

Amigo, Nisete Augusto de January 1998 (has links)
Made available in DSpace on 2012-09-06T01:11:12Z (GMT). No. of bitstreams: 2 license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) 106.pdf: 3009480 bytes, checksum: 3073b80b6df5fc1810662a9fd636a233 (MD5) Previous issue date: 1998 / Fundação Oswaldo Cruz. Escola Nacional de Saúde Pública Sergio Arouca. Rio de Janeiro, RJ, Brasil. / As normas utilizadas na avaliaçäo de lançamento de esgotos, NT-202, DZ-205 e DZ-215, foram utilizadas, para verificar se os esgotos domésticos, portanto de origem näo industrial, realmente mantêm esta condiçäo nos dias atuais, década de 90 e com cinqüenta anos de evoluçäo da industria química. O esgoto bruto, estudado, representativo de uma populaçäo de 4000 habitantes, apresentou uma carga orgânica unitária de 98 g/hab.d, maior do que a prevista pela DZ-215, que é de 54 g/hab.d. A concentraçäo de MBAS encontrada, de 6,09 mg/l, é maior que a concentraçäo permitida pela NT-202 para o lançamento industrial, na rede de esgotos, que é de 2,0 mg/l; implica num consumo percapita de surfactante de 2,9 g/hab.d, contra 4,0g/hab.d previstos na Europa Ocidental (Painter & Zabel, 1988) e 4,5 g/hab.d em Owlwood, U.K (Holt, et al., 1995). Os metais pesquisados estäo todos abaixo dos valores preconizados pela NT-202. O cádmio foi o que registrou maior percentual comparado com limite exigido, 29 por cento , seguido igualmente do chumbo e do zinco com 18 por cento, e, ainda, a maior variaçäo percentual de crescimento do consumo percapita. Esse crescimento poderia ser uma tendência ligada ao consumo exagerado, quer por desperdício ou excesso de oferta de produtos, somado, provavelmente, ao controle inadequado desses elementos nos produtos. A relaçäo DBO/DQ, de referência para a NT-205 (FEEMA, 1991) como indicativo da necessidade de implantaçäo de sistema de pré-tratamento de controle de carga orgânica näo-biodegradável, a ser lançada na rede de esgotos, por uma atividade poluidora industrial. Essas tendências devem ser consideradas, para que se busque formas de controle aplicáveis aos esgotos domésticos, ante a expectativa de mais alteraçöes futuras. A carga industrial, pontual, pode ser devidamente controlada para näo agredir o meio ambiente, ou, aos cofres públicos, com demandas näo previstas para as ETE'S. O controle de uma carga difusa - esgoto doméstico - formada pelos mais variados produtos domissanitários, cosméticos e de higiene, exigirá, num futuro próximo, outras formas de controle, para que näo atinja valores que venha a comprometer o tratamento municipal de esgotos e o meio ambiente. / The FEEMA regulations to valuation sewers throwing, NT-202, DZ-205 and DZ-215, were used in order to verify if the domestic sewers, thus of non-industrial origin, really maintain this condition nowadays, in the ninety’s, and with fifty years of evolution of chemical industry. The raw sewer, up in this work, representative of a population of 4.000 inhabitants, presented an unitary organic load of 98 g/cap.d, larger than that expected by DZ-215, that is of 54g/cap.d. The founded MBAS concentration, of 6.09 mg/l, is larger than the NT-202 standard concentration for industrial throwing in the sewerage system, that is of 2.0 mg/l. This imply in a “per capita” surfactant consumption of 2.9 g/cap.d, against 4.0 g/cap.d foreseen in the Western Europe (Painter & Zabel, 1988) and 4.5 g/cap.d in Owlwood, U.K. (Holt, et al, 1995). The researched metals are all lower than the NT-202 standardized values. The cadmium was the one that recorded the larger percentage, compared with the required standard values, 29%, followed equally by lead and zinc with 18%, and yet, the larger percentage variation of “per capita” consumption increase. This increase could be a tendency associated to an excessive consumption, that by wastefulness or a surplus in the products supply, probably added to the inadequate control of these elements in the products. The found average relation BOD/QOD was 0.6 ± 0.17mg/l. The relation BOD/QOD was 2.3±0.7mg/l, having reached in some samples a value higher than 4:1, which value is the background to indicate the necessity of introduction of pre-treatment system (FEEMA, NT-205) as an indicative to control a non-biodegradable organic load, to be thrown in the sewerage system, by an industrial polluter activity. This tendency must be considerate in order to search control lines to be applied in domestic sewers, foreseeing further future changes. The industrial load, can be properly controlled for d’ont pollute the environment or give rise to public costs, with contests unforeseen loads for the ETE’s. The control of a diffuse load - domestic sewer - composed of the most varied household, cosmetics and hygienic products, will demand, in the near future, other lines of control, to the effect of do not reach values that could compromise the municipal sewers treatment and the environment.
9

Viabilidade do uso de efluentes tratados por zona de raízes na irrigação: estudo de caso na Vila Dois Rios - Ilha Grande, RJ / Constructed of the use of efluente treated by try to use it in irrigation: case study in the Vila Dois Rios - Ilha Grande, RJ

Kaczala, Fábio January 2005 (has links)
Made available in DSpace on 2012-09-06T01:12:43Z (GMT). No. of bitstreams: 2 license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) 830.pdf: 2200736 bytes, checksum: 944e99d433e4bb3d4d9dc05ec86761f1 (MD5) Previous issue date: 2005 / A escassez de água doce, atualmente está gerando diversos tipos de problemas, devido aos usos múltiplos e demanda crescente, principalmente para as necessidades fisiológicas humanas, e atividades econômicas como a indústria, e a irrigação para produção de alimentos. Os países mais atingidos por esta escassez buscam alternativas de. Uma destas alternativas são as águas residuárias tratadas. Atualmente a atividade humana que representa o maior consumo de água é a irrigação, o que a torna a atividade com maior necessidade de recursos alternativos. O uso de águas residuárias para a irrigação, requer uma qualidade microbiológica e físico-química que não traga riscos ao meio ambiente e principalmente à saúde pública. O presente trabalho teve como objetivo analisar a qualidade microbiológica e físico-química do efluente de um sistema de tratamento biológico de esgotos domésticos de pequeno gerador utilizando o processo de Zona de Raízes como polimento final, e a viabilidade de utilizá-lo para a irrigação de acordo com algumas diretrizes existentes para proteção à saúde pública. Foram analisados alguns parâmetros, sendo que os de maior importância para a saúde pública foram os parâmetros biológicos Escherichia coli e ovos de Helmintos, além do indicador coliforme totais. O sistema foi analisado em um período de 6 meses e demonstrou viabilidade para a aplicação e utilização do efluente na irrigação, principalmente para fins de culturas industrialmente processadas, silvicultura, plantas forrageiras, culturas frutíferas arbóreas e também de cereais.
10

Remoção de fósforo de unidade de flotação da estação de tratamento de esgoto

Machado, Fernando Ruas 12 September 2007 (has links)
The flotation made by dissolved air (DFA) is an effective technology on the removal of the phosphorus during the treatment of the sewage system. The city of Uberlândia, nowadays, treats the whole domestic sewage, through three stations equipped with anaerobic reactors followed by the units of flotation. The sewage systems normally present between 4 and 15 mg / L of phosphate (METCALF; EDDY,1991). The phosphorus that is found in the sewage system under the format of phosphate is the most important limiting factor of the productivity in the most of the continental waters, being responsible for the artificial eutrophication . It s necessary to promote the chemical coagulation and the flocculation of the scattered particles in the water so that the flotation of the sewage system becomes successful. The hydrophobicity, the presence of micro air bubbles, and the chemical products added to the tributary, are also essential factors in the flotation process. The operation of flotation unit involves many variables, and the most important are the outflow of the air, the velocity of the dredging machine, the concentration of coagulant and polymer. This way, the planning and analysis of the experiments are more trustworthy, when statistic techniques are used. The determination of a relationship between the variables of the process and the removal of phosphorus provides a better evaluation of the efficiency of the flotation unit. From this perspective, a central compound planning was made to determine the equation of the removal of the phosphorus because of the outflow of the air, the velocity of the dredging machine, the concentration of coagulant and polymer. According to the main experimental results the average of the efficiency was 85% on the flotation unit, which provided an improvement of the environmental quality of the hydric body that receives the treated effluents. The variables of the concentration of coagulant and the outflow of the air influence significantly on the removal of the phosphorus. The cationic polymer used through this work did not prove efficient on the treatment of the pos reactor effluent. The best operational conditions for ETEIpanema were determined on the intermediary level of the experimental range used ( the concentration of coagulant of 80 ppm, the polymer concentration of 2,5 ppm, the velocity of the dredging machine of 1,15 RPM and the outflow of the air of 20 L/s), since high values of phosphorus removal was reached together with a decrease of the use of inputs and a lesser wearing of the unit of flotation. / A flotação por ar dissolvido (FAD) é uma tecnologia eficaz na remoção do fósforo durante o tratamento de esgoto sanitário. A cidade de Uberlândia, atualmente, trata todo o esgoto doméstico, através de três estações equipadas com reatores anaeróbios seguidos de unidade de flotação. Os esgotos sanitários geralmente apresentam entre 4 e 15 mg/L de fósforo (METCALF; EDDY, 1991). O fósforo, que se encontra no esgoto sob a forma de fosfato, é o principal fator limitante da produtividade na maioria das águas continentais, sendo responsável pela eutrofização artificial. É necessário que se promova a coagulação química e a floculação das partículas dispersas na água para que a flotação de esgotos sanitários tenha sucesso. A hidrofobicidade, a presença de micro bolhas de ar, e os produtos químicos adicionados ao afluente, também são fatores indispensáveis no processo de flotação. A operação da unidade de flotação envolve diversas variáveis, sendo as principais vazão de ar, velocidade da roda de dragagem, concentração de coagulante e polímero. Assim, a análise e planejamento dos experimentos são mais confiáveis, quando se utiliza técnicas estatísticas. A determinação de uma relação entre as variáveis do processo e a remoção de fósforo proporciona uma melhor avaliação da eficiência da unidade de flotação. Dentro desta visão, realizou-se um planejamento composto central para determinar a equação de remoção de fósforo em função da vazão de ar, da velocidade da roda de dragagem, concentração de coagulante e polímero. De acordo com os principais resultados experimentais a eficiência média obtida foi de 85% na unidade de flotação, o que possibilitou uma melhoria na qualidade ambiental do corpo hídrico receptor destes efluentes tratados. As variáveis de concentração de coagulante e da vazão de ar influenciam significativamente na remoção de fósforo. O polímero catiônico utilizado durante o decorrer deste trabalho não se mostrou eficiente no tratamento do efluente pós-reator. As melhores condições operacionais para a ETE-Ipanema foram determinadas no nível intermediário da faixa experimental utilizada (concentração de coagulante de 80 ppm, concentração de polímero de 2,5 ppm, velocidade da roda de dragagem de 1,15 RPM e vazão de ar de 20 L/s), pois foram alcançados altos valores de remoção de fósforo aliados a uma diminuição do uso de insumos e menor desgaste da unidade de flotação. / Mestre em Engenharia Química

Page generated in 0.0754 seconds