• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 22
  • Tagged with
  • 22
  • 22
  • 16
  • 15
  • 15
  • 12
  • 9
  • 9
  • 9
  • 8
  • 8
  • 6
  • 6
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

"Doença do refluxo gastroesofágico: influência da cepa cagA do Helicobacter pylori na resposta terapêutica à inibição da bomba protônica em pacientes com esofagite erosiva leve" / Gastroesphageal reflux disease : influence of cagA strains of Helicobacter pylori in the proton pump inhibition therapeutic response in patients with low grade erosive esophagitis

Ricardo Correa Barbuti 20 April 2006 (has links)
Foram estudados 83 pacientes com esofagite erosiva graus I e II, pela classificação de Savary-Miller modificada, divididos em 3 grupos. Um sem Helicobacter pylori, dois outros com Helicobacter pylori, com e sem o gene cagA. Avaliou-se a participação da bactéria e de seu gene cagA, associados à estudo histopatológico de antro e corpo e à gastrinemia basal, na cicatrização da mucosa do esôfago após tratamento com pantoprazol 40 mg ao dia por 6 semanas. Verificou-se que a presença do Helicobacter pylori, independentemente da presença do gene cagA, facilita a cicatrização esofágica. Indivíduos com gastrinemias maiores também tendem a cicatrizar melhor. Não houve relação do resultado do estudo histopatológico com a resposta terapêutica / Eighty three patients with grade I-II of the modified Savary-Miller classification have been studied. They were divided in three groups. One without Helicobacter pylori infection, two with the bacterium, one with and other without the cagA gene. We verified the influence of cagA status, histopathology of antrum and body of the stomach and gastrinemia in the esophageal healing rates after treatment with pantoprazole 40 mg once a day for six weeks. Helicobacter pylori presence but not cagA status and gastrinemia led to better healing rates. Histopathology of the gastric mucosa did not influence the response
12

Existe associação entre dismotilidade esofágica e hérnia hiatal em pacientes com doença do refluxo gastroesofágico? / Importance of hiatal hernia for occurence of ineffective esophageal motility in patients with gastroesophageal reflux disease

Conrado, Leonardo Menegaz January 2010 (has links)
Introdução: A fisiopatologia da Doença do Refluxo Gastroesofágico (DRGE) é multifatorial, sendo a motilidade esofágica um dos fatores implicados na sua gênese. Todavia, ainda não há consenso sobre a existência de associação entre dismotilidade e Hérnia Hiatal (HH) em pacientes com DRGE. Esse estudo tem como objetivo estabelecer a prevalência de Dismotilidade Esofágica (DE) em pacientes com HH e avaliar se a herniação é fator relacionado à DE. Métodos: Foram estudados 356 pacientes com diagnóstico clínico de DRGE submetidos à Endoscopia Digestiva Alta e Manometria Esofágica. Hérnia Hiatal foi definida endoscopicamente por uma distância igual ou maior que 2 cm entre o pinçamento diafragmático e a junção escamo-colunar e Dismotilidade Esofágica quando a ME identificou amplitude das ondas peristálticas no esôfago distal < 30 mmHg e/ou menos de 80% de contrações efetivas. Foi feita a divisão dos pacientes para a análise estatística em 2 grupos, com e sem HH. Resultados: Pacientes com DRGE portadores de HH tiveram prevalência de DE igual a 14,8% e os sem HH, prevalência de 7,7% (p = 0,041). O grupo de pacientes com HH apresentou também maior frequência de esofagite erosiva (47,5% contra 24,2%, p <0,001), menor valor de pressão no EEI (10,4 versus 13,10; p < 0,001) e maior frequência de indivíduos com valores de pH-metria anormais (p < 0,001). A razão bruta de prevalências de DE, segundo a presença de HH, foi 1,92 (IC: 1,04 - 3,53; p = 0,037), porém essa associação não persistiu quando controlada por idade, esofagite, pH-metria alterada e EEI alterado (RP ajustada: 1,69; IC: 0,68 – 4,15; p = 0,257). Conclusão: Apesar da prevalência de DE no grupo HH ter sido maior do que no grupo sem HH, a associação entre HH e DE em indivíduos com DRGE desaparece ao se controlar por co-variáveis relevantes, levando a crer que neste tipo de paciente, HH não é fator de risco independente destas variáveis. / Introduction: The pathophysiology of gastroesophageal reflux disease is multifactorial, where esophageal motility is one of the factors implicated in its genesis. However, there is still no consensus on the existence of an association between esophageal dysmotility and hiatal hernia in patients with gastroesophageal reflux disease. The objective of this study was to establish the prevalence of esophageal dysmotility in patients with hiatal herina and to determine if herniation is a factor related to esophageal dysmotility. Methods: The study included 356 patients with a clinical diagnosis of gastroesophageal reflux disease submitted to upper digestive endoscopy and esophageal functional dagnostics. Hiatal Hernia was defined endoscopically by a distance equal to or greater than 2 cm between the diaphragmatic constriction and the squamo-columnar junction and esophageal dysmoyility when the esophageal manometry identified the amplitude of the peristaltic waves in the distal esophagus are < 30 mmHg and/or less than 80% of effective contractions. For statistical analysis, the patients were divided into 2 grups: with and without HH. Results: Gastroesophageal reflux disease patients with hiatal hernia had a prevalence of esophageal dysmotility equal to 14.8% and those without hiatal hernia, a prevalence of 7.7% (p = 0.041). The group of patients with hiatal hernia also showed a greater frequency of erosive esophagitis (47.5% versus 24.2%, p <0.001), lower low esophageal sphincter pressure (10.4 versus 13.10; p < 0.001) and greater frequency of individuals with abnormal pH-metry values (p < 0.001). The crude prevalence ratios for esophageal dysmotility, according to the presence of hiatal hernia, was 1.92 (CI: 1.04 - 3.53; p = 0.037), but this association did not persist when controlled for age, esophagitis, altered pH-metry and altered low esophageal sphincter (adjusted PR: 1.69; CI: 0.68 – 4.15; p = 0.257). Conclusion: Despite the prevalence of esophageal dysmotility in the hiatal hernia group being higher than that in the group without hiatal hernia, the association between hiatal hernia and esophageal dysmotility in individuals with gastroesophageal reflux disease disappeared on controlling for relevant co-variables, leading us to believe that in this type of patient, hiatal hernia is not a risk factor independent of these variables.
13

Existe associação entre dismotilidade esofágica e hérnia hiatal em pacientes com doença do refluxo gastroesofágico? / Importance of hiatal hernia for occurence of ineffective esophageal motility in patients with gastroesophageal reflux disease

Conrado, Leonardo Menegaz January 2010 (has links)
Introdução: A fisiopatologia da Doença do Refluxo Gastroesofágico (DRGE) é multifatorial, sendo a motilidade esofágica um dos fatores implicados na sua gênese. Todavia, ainda não há consenso sobre a existência de associação entre dismotilidade e Hérnia Hiatal (HH) em pacientes com DRGE. Esse estudo tem como objetivo estabelecer a prevalência de Dismotilidade Esofágica (DE) em pacientes com HH e avaliar se a herniação é fator relacionado à DE. Métodos: Foram estudados 356 pacientes com diagnóstico clínico de DRGE submetidos à Endoscopia Digestiva Alta e Manometria Esofágica. Hérnia Hiatal foi definida endoscopicamente por uma distância igual ou maior que 2 cm entre o pinçamento diafragmático e a junção escamo-colunar e Dismotilidade Esofágica quando a ME identificou amplitude das ondas peristálticas no esôfago distal < 30 mmHg e/ou menos de 80% de contrações efetivas. Foi feita a divisão dos pacientes para a análise estatística em 2 grupos, com e sem HH. Resultados: Pacientes com DRGE portadores de HH tiveram prevalência de DE igual a 14,8% e os sem HH, prevalência de 7,7% (p = 0,041). O grupo de pacientes com HH apresentou também maior frequência de esofagite erosiva (47,5% contra 24,2%, p <0,001), menor valor de pressão no EEI (10,4 versus 13,10; p < 0,001) e maior frequência de indivíduos com valores de pH-metria anormais (p < 0,001). A razão bruta de prevalências de DE, segundo a presença de HH, foi 1,92 (IC: 1,04 - 3,53; p = 0,037), porém essa associação não persistiu quando controlada por idade, esofagite, pH-metria alterada e EEI alterado (RP ajustada: 1,69; IC: 0,68 – 4,15; p = 0,257). Conclusão: Apesar da prevalência de DE no grupo HH ter sido maior do que no grupo sem HH, a associação entre HH e DE em indivíduos com DRGE desaparece ao se controlar por co-variáveis relevantes, levando a crer que neste tipo de paciente, HH não é fator de risco independente destas variáveis. / Introduction: The pathophysiology of gastroesophageal reflux disease is multifactorial, where esophageal motility is one of the factors implicated in its genesis. However, there is still no consensus on the existence of an association between esophageal dysmotility and hiatal hernia in patients with gastroesophageal reflux disease. The objective of this study was to establish the prevalence of esophageal dysmotility in patients with hiatal herina and to determine if herniation is a factor related to esophageal dysmotility. Methods: The study included 356 patients with a clinical diagnosis of gastroesophageal reflux disease submitted to upper digestive endoscopy and esophageal functional dagnostics. Hiatal Hernia was defined endoscopically by a distance equal to or greater than 2 cm between the diaphragmatic constriction and the squamo-columnar junction and esophageal dysmoyility when the esophageal manometry identified the amplitude of the peristaltic waves in the distal esophagus are < 30 mmHg and/or less than 80% of effective contractions. For statistical analysis, the patients were divided into 2 grups: with and without HH. Results: Gastroesophageal reflux disease patients with hiatal hernia had a prevalence of esophageal dysmotility equal to 14.8% and those without hiatal hernia, a prevalence of 7.7% (p = 0.041). The group of patients with hiatal hernia also showed a greater frequency of erosive esophagitis (47.5% versus 24.2%, p <0.001), lower low esophageal sphincter pressure (10.4 versus 13.10; p < 0.001) and greater frequency of individuals with abnormal pH-metry values (p < 0.001). The crude prevalence ratios for esophageal dysmotility, according to the presence of hiatal hernia, was 1.92 (CI: 1.04 - 3.53; p = 0.037), but this association did not persist when controlled for age, esophagitis, altered pH-metry and altered low esophageal sphincter (adjusted PR: 1.69; CI: 0.68 – 4.15; p = 0.257). Conclusion: Despite the prevalence of esophageal dysmotility in the hiatal hernia group being higher than that in the group without hiatal hernia, the association between hiatal hernia and esophageal dysmotility in individuals with gastroesophageal reflux disease disappeared on controlling for relevant co-variables, leading us to believe that in this type of patient, hiatal hernia is not a risk factor independent of these variables.
14

Existe associação entre dismotilidade esofágica e hérnia hiatal em pacientes com doença do refluxo gastroesofágico? / Importance of hiatal hernia for occurence of ineffective esophageal motility in patients with gastroesophageal reflux disease

Conrado, Leonardo Menegaz January 2010 (has links)
Introdução: A fisiopatologia da Doença do Refluxo Gastroesofágico (DRGE) é multifatorial, sendo a motilidade esofágica um dos fatores implicados na sua gênese. Todavia, ainda não há consenso sobre a existência de associação entre dismotilidade e Hérnia Hiatal (HH) em pacientes com DRGE. Esse estudo tem como objetivo estabelecer a prevalência de Dismotilidade Esofágica (DE) em pacientes com HH e avaliar se a herniação é fator relacionado à DE. Métodos: Foram estudados 356 pacientes com diagnóstico clínico de DRGE submetidos à Endoscopia Digestiva Alta e Manometria Esofágica. Hérnia Hiatal foi definida endoscopicamente por uma distância igual ou maior que 2 cm entre o pinçamento diafragmático e a junção escamo-colunar e Dismotilidade Esofágica quando a ME identificou amplitude das ondas peristálticas no esôfago distal < 30 mmHg e/ou menos de 80% de contrações efetivas. Foi feita a divisão dos pacientes para a análise estatística em 2 grupos, com e sem HH. Resultados: Pacientes com DRGE portadores de HH tiveram prevalência de DE igual a 14,8% e os sem HH, prevalência de 7,7% (p = 0,041). O grupo de pacientes com HH apresentou também maior frequência de esofagite erosiva (47,5% contra 24,2%, p <0,001), menor valor de pressão no EEI (10,4 versus 13,10; p < 0,001) e maior frequência de indivíduos com valores de pH-metria anormais (p < 0,001). A razão bruta de prevalências de DE, segundo a presença de HH, foi 1,92 (IC: 1,04 - 3,53; p = 0,037), porém essa associação não persistiu quando controlada por idade, esofagite, pH-metria alterada e EEI alterado (RP ajustada: 1,69; IC: 0,68 – 4,15; p = 0,257). Conclusão: Apesar da prevalência de DE no grupo HH ter sido maior do que no grupo sem HH, a associação entre HH e DE em indivíduos com DRGE desaparece ao se controlar por co-variáveis relevantes, levando a crer que neste tipo de paciente, HH não é fator de risco independente destas variáveis. / Introduction: The pathophysiology of gastroesophageal reflux disease is multifactorial, where esophageal motility is one of the factors implicated in its genesis. However, there is still no consensus on the existence of an association between esophageal dysmotility and hiatal hernia in patients with gastroesophageal reflux disease. The objective of this study was to establish the prevalence of esophageal dysmotility in patients with hiatal herina and to determine if herniation is a factor related to esophageal dysmotility. Methods: The study included 356 patients with a clinical diagnosis of gastroesophageal reflux disease submitted to upper digestive endoscopy and esophageal functional dagnostics. Hiatal Hernia was defined endoscopically by a distance equal to or greater than 2 cm between the diaphragmatic constriction and the squamo-columnar junction and esophageal dysmoyility when the esophageal manometry identified the amplitude of the peristaltic waves in the distal esophagus are < 30 mmHg and/or less than 80% of effective contractions. For statistical analysis, the patients were divided into 2 grups: with and without HH. Results: Gastroesophageal reflux disease patients with hiatal hernia had a prevalence of esophageal dysmotility equal to 14.8% and those without hiatal hernia, a prevalence of 7.7% (p = 0.041). The group of patients with hiatal hernia also showed a greater frequency of erosive esophagitis (47.5% versus 24.2%, p <0.001), lower low esophageal sphincter pressure (10.4 versus 13.10; p < 0.001) and greater frequency of individuals with abnormal pH-metry values (p < 0.001). The crude prevalence ratios for esophageal dysmotility, according to the presence of hiatal hernia, was 1.92 (CI: 1.04 - 3.53; p = 0.037), but this association did not persist when controlled for age, esophagitis, altered pH-metry and altered low esophageal sphincter (adjusted PR: 1.69; CI: 0.68 – 4.15; p = 0.257). Conclusion: Despite the prevalence of esophageal dysmotility in the hiatal hernia group being higher than that in the group without hiatal hernia, the association between hiatal hernia and esophageal dysmotility in individuals with gastroesophageal reflux disease disappeared on controlling for relevant co-variables, leading us to believe that in this type of patient, hiatal hernia is not a risk factor independent of these variables.
15

Estudo prospectivo comparativo de duas modalidades de posicionamento do sensor de pH-metria esofágica prolongada: por manometria esofágica e pela viragem do pH / Comparative prospective study of two positioning modes of 24-hour esophageal pH monitoring: by esophageal manometry and by the pH step-up technique

Frare, Rita de Cassia 18 January 2008 (has links)
Por padronização aceita internacionalmente, posiciona-se o sensor distal de pH-metria esofágica a 5 cm acima da borda superior do esfíncter inferior do esôfago, identificado por manometria esofágica. Porém, vários autores sugerem técnicas alternativas de posicionamento que prescindem da manometria; dentre essas, destaca-se a da viragem do pH. Esse tema é controverso: alguns autores consideram a técnica da viragem confiável, outros afirmam que não é. Considerando-se a polêmica existente e o pequeno número de trabalhos prospectivos com amostra e metodologia adequadas, idealizamos o presente estudo, que tem por objetivos avaliar a adequação do posicionamento do sensor distal de pH-metria baseado na técnica da viragem, analisando-se a presença, o grau e o tipo de erro de posicionamento que tal técnica proporciona e a influência da posição adotada pelo paciente durante a manobra. Foram estudados, de modo prospectivo, 1031 pacientes encaminhados para realização de pH-metria esofágica. Durante entrevista clínica, foram registrados os dados demográficos e as queixas clínicas apresentadas. Todos pacientes foram submetidos à manometria esofágica para localização do esfíncter inferior do esôfago e à técnica da viragem do pH, que consiste na introdução do sensor de pH-metria na câmara gástrica e na tração gradual do mesmo até que o pH vire para níveis superiores a 4. A identificação do ponto de viragem foi realizada de dois modos distintos, caracterizando dois grupos de estudo: com o paciente sentado (Grupo I - 450 pacientes) e em decúbito dorsal horizontal (Grupo II - 581 pacientes). Após a identificação do ponto de viragem, o sensor distal de pH-metria era posicionado na posição padronizada, baseada na localização manométrica do esfíncter. Registrava-se onde seria posicionado o sensor de pH se fosse adotada a técnica da viragem. Para avaliação da adequação do posicionamento, considerou-se que o erro é representado pela diferença (em centímetros) entre a localização padronizada e a localização que seria adotada caso fosse empregada a técnica da viragem. Considerou-se que o erro seria grosseiro se fosse maior que 2 cm. Analisou-se também o tipo de erro mais freqüente: se acima ou abaixo da posição padronizada. Observou-se que se fosse adotada a técnica da viragem, haveria erro no posicionamento do sensor em 945 pacientes (91,6%). Quanto ao grau de erro, haveria erro grosseiro em 597 (63,2%) casos. Em relação ao tipo de erro, o sensor seria posicionado abaixo do local padronizado em 857 (90,7%) pacientes. Em relação à interferência da posição adotada pelo paciente durante a técnica da viragem, observou-se que não houve diferença significante entre os grupos de estudo, em nenhum dos parâmetros analisados. Conclui-se que: 1. o posicionamento do sensor distal de pH-metria pela técnica da viragem não é confiável; 2. a técnica da viragem proporciona margem de erro expressiva; 3. o tipo de erro mais comum que tal modalidade técnica proporciona é o posicionamento mais distal do sensor, que pode superestimar a ocorrência de refluxo; 4. não há influência da posição adotada pelo paciente durante a realização da técnica da viragem do pH, na eficiência do método / By internationally accepted standardization, the esophageal pH-meter distal sensor is positioned 5 cm above the superior border of the esophagus lower sphincter, identified by esophageal manometry. However, several authors suggest alternative positioning techniques that leave out the manometry; among such techniques, the pH step-up is the one to be pointed out. This subject is controversial; some publications state that the step-up technique is not reliable while some others consider it reliable. Considering the existent controversy and the small number of prospective works with suitable sample and methodology, we have idealized the present study, that aims the evaluation of the suitability of the pH-meter distal sensor positioning based on the step-up technique, by analyzing the presence, the degree and the type of the error of positioning that such technique provides and the influence of the position adopted by the patient during the procedure. 1031 patients conducted to the esophageal pH-meter procedure were studied in a prospective way. During the clinical interview, the demographic data and the presented clinical complaints were registered. All the patients were submitted to both esophageal manometry in order to localize the esophagus lower sphincter and the pH step-up technique, that consists of the introduction of the pH-meter sensor in the gastric chamber and in the sensors gradual traction until the pH steps up to levels over 4. The step-up point was identified by two distinct ways, characterizing two study groups: with the setting patient (Group I - 450 patients) and in supine position (Group I I- 581 patients). After the step-up point identification, the pH-meter distal sensor was placed in the standard position, based on the sphincter manometric placement. It was registered where the pH sensor would be positioned if the step-up technique were adopted. To evaluate the positioning suitability, the error was considered to be represented by the difference (in centimeters) between the suitable placement (manometry) and the one that would be adopted in case the step-up technique were adopted. The positioning error was considered rough if it were larger than 2 cm. The most frequent type of error was also analyzed: if above or below the standard position. It was observed that if the step-up technique were adopted, there would be error in the sensor positioning in 945 patients (91.6%). In terms of error degree, there would be a rough error in 597 (63.2%) cases. Concerning the type of error, the sensor would be positioned below the standard place in 857 (90.7%) patients. As to the interference of the position adopted by the patient during the step-up technique, it was observed that there was no significant difference among the groups of study, in any of the analyzed parameters. It was concluded that: 1. the positioning of the pH-meter distal sensor by the step-up technique is not reliable; 2. the step-up technique provides expressive error margin; 3. the most common type of error that such technique mode provides is the placement of the sensor below the standard positioning, which may overestimate the reflux occurrence; 4. there is no influence in the position adopted by the patient during the pH step-up technique procedure, in terms of method efficiency
16

Estudo comparativo de duas modalidades de mensuração do refluxo gastroesofágico: pHmetria esofágica convencional e pHmetria sem cateter / Comparative study of two modes of gastroesophageal reflux measuring: conventional esophageal pH monitoring and wireless pH monitoring

Azzam, Rimon Sobhi 02 September 2009 (has links)
A pHmetria esofágica é considerada o melhor método diagnóstico do refluxo ácido gastroesofágico. Contudo, é bastante incômoda e restringe consideravelmente as atividades cotidianas do paciente. A pHmetria sem cateter foi desenvolvida para contornar tais limitações. OBJETIVOS: Comparar as pHmetrias convencional e sem cateter em relação: ao grau de incômodo e limitações das atividades cotidianas, à ocorrência de falhas técnicas relevantes, à capacidade de detecção do refluxo e de relacionar as queixas clínicas com o mesmo. Objetiva-se também, verificar se a monitorização mais prolongada (48 horas) oferece vantagens em relação à monitorização usual (24 horas). MÉTODOS: Foram estudados, de modo prospectivo, 25 pacientes encaminhados para realização de pHmetria esofágica, com sintomas típicos da doença do refluxo gastroesofágico, como queixa predominante. Todos pacientes foram submetidos à entrevista clínica, manometria esofágica e realização, com período inicial simultâneo, de pHmetrias com cateter (24 horas) e sem cateter (48 horas). Foi aplicado questionário para avaliação do grau de incômodo, após o término das pHmetrias. RESULTADOS: Quanto ao incômodo na introdução dos sensores de medida de pH, quinze (60%) pacientes apontaram a cápsula como mais incômoda e dez (40%) o cateter (p=0,327). Durante a monitorização, o incômodo foi menor no segundo dia em relação ao primeiro, em todos os itens do questionário (p<0,05). Houve queda precoce da cápsula em um (4%) paciente e nenhuma falha técnica relevante na pHmetria com cateter (p=0,463). As porcentagens de tempo de refluxo (total, ortostático e supino) foram mais elevadas na pHmetria sem cateter (p<0,05). O Índice de Sintomas foi positivo em 12 (48%) pacientes na pHmetria com cateter e em 13 (52%) na pHmetria sem cateter (p=0,777). O Índice de Sintomas foi positivo em 13 (52%) pacientes na pHmetria por tempo usual (24h) e em 14 (56%) na mais prolongada (48h) (p=1,000). CONCLUSÕES: Nas condições da presente pesquisa: 1) Não há diferença significante entre as duas modalidades de pHmetria, em relação ao grau de incômodo na introdução dos sensores de pH (cápsula X cateter) e nem quanto à ocorrência de falhas técnicas relevantes durante o exame; 2) A monitorização do refluxo pela pHmetria sem cateter é menos incômoda que a com cateter. A pHmetria sem cateter detecta refluxo em porcentagens superiores aos detectados pela pHmetria convencional; 3) Os dois métodos de pHmetria têm capacidades semelhantes de relacionar as queixas clínicas com o refluxo; 4) A monitorização mais prolongada (48h) não proporciona incremento significante na capacidade de relacionar as queixas clínicas com o refluxo, em relação à monitorização por tempo usual (24h). / Esophageal pH monitoring is considered to be the gold standard for the diagnosis of gastroesophageal acid reflux. However, this method is very troublesome and considerably limits the patients routine activities. Wireless pH monitoring was developed to avoid these restrictions. OBJECTIVES: To compare conventional and wireless pH monitoring in relation to: routine activity limitations and degree of discomfort, the occurrence of relevant technical failures, the ability to detect reflux and to correlate the clinical symptoms to it. An additional objective is to determine if longer monitoring (48-hour) offers any advantages over usual monitoring (24-hour). METHOD: Twenty-five patients referred for esophageal pH monitoring and with typical symptoms of gastroesophageal reflux disease as the main complaint were studied prospectively. All patients underwent clinical interview, esophageal manometry and were submitted, with a simultaneous initial period, to 24-hour catheter pH monitoring and 48-hour wireless pH monitoring. After each pH-metry the patients completed a questionnaire on the degree of discomfort. RESULTS: Fifteen (60%) patients reported a higher level of discomfort to introduce the capsule and ten (40%) to introduce the catheter (p=0.327). For all questionnaire items, less discomfort was reported during the second day of monitoring in comparison to the first day (p<0.05). Early capsule detachment occurred in one (4%) case and there were no relevant technical failures with the catheter pH monitoring (p=0.463). Percentages of reflux time (total, upright and supine) were higher with the wireless pH monitoring (p<0.05). The Symptom Index was positive in 12 (48%) patients with catheter pH monitoring and in 13 (52%) with wireless pH monitoring (p=0.777). The Symptom Index was positive in 13 (52%) patients with usual 24-hour pH-metry and in 14 (56%) with longer pH-metry (48-hour) (p=1.000). CONCLUSIONS: Under the conditions of the current research: 1) No significant differences were reported between the two methods of pH monitoring, in relation to the degree of discomfort to introduce the pH sensors (capsule X catheter) or in regard to relevant technical failures; 2) During pH monitoring, the wireless system is better tolerated than the catheter. Wireless pH monitoring detected higher percentages of reflux time than the conventional pH-metry; 3) The two methods of pH monitoring were comparable in correlating the clinical symptoms with the reflux; 4) The longer 48-hour pH monitoring does not significantly improve the ability to correlate the clinical symptoms with the reflux in relation to the 24-hour pH monitoring.
17

Estudo comparativo da mensuração do refluxo gastroesofágico, por pHmetria esofágica prolongada, em dois níveis: a 5 e a 3 cm acima do esfíncter inferior do esôfago / Comparative study of the measurement of gastroesophageal reflux, by prolonged esophageal pH-metry, at two levels: 5 and 3 cm above the lower esophageal sphincter

Brandão, Jeovana Ferreira 30 July 2010 (has links)
Racional: Para a monitorização do refluxo ácido gastroesofágico, por pHmetria, convencionalmente, posiciona-se o sensor de pH 5 cm acima da borda superior do esfíncter inferior do esôfago. Porém, esta parece não ser a localização ideal para estabelecer-se o diagnóstico da doença do refluxo, visto que as alterações da mucosa esofágica decorrentes do refluxo ocorrem, principalmente, no segmento mais distal do órgão e que a exposição ácida diminui progressivamente do segmento mais distal do esôfago em direção ao proximal. Objetivos: Comparar dois níveis de mensuração do refluxo: o convencional com um mais distal (3 cm acima da borda superior do esfíncter inferior do esôfago) quanto à: ocorrência de alterações no traçado sugestivas de detecção de pH intragástrico, quantificação do refluxo e relação do mesmo com as queixas clínicas. Objetiva-se ainda, comparar duas modalidades de estudo da relação entre queixa clínica e refluxo: o Índice de Sintomas e a Probabilidade de Associação de Sintomas. Material e métodos: Foram estudados, prospectivamente, pacientes com sintomas típicos da doença do refluxo, submetidos à: entrevista clínica, endoscopia digestiva alta, manometria esofágica e pHmetria com dois sensores de registro: um proximal posicionado na localização convencional e um mais distal (3 cm acima da borda superior do esfíncter inferior do esôfago). Resultados: Foram incluídos 105 pacientes; 47 (44,8%) com esofagite erosiva, 34 (32,4%) com esofagite não-erosiva e 24 (22,9%) sem esofagite ao estudo endoscópico. Não houve alterações no traçado sugestivas de detecção de pH intragástrico em nenhum paciente. A quantificação do refluxo foi significantemente maior no segmento distal do esôfago, em relação ao proximal, em todos os parâmetros analisados: percentagem de tempo total de refluxo, percentagem do tempo de refluxo em posição ortostática, percentagem de refluxo em posição supina, número de episódios de refluxos, número de refluxos com duração maior que 5 minutos, duração do episódio mais longo de refluxo e pontuação de DeMeester. O Índice de Sintoma foi positivo em 46 (67,7%) pacientes no local convencional e em 49 (72,1%) no local mais distal; a Probabilidade de Associação de Sintomas foi positiva em 10 (14,4%) pacientes no local convencional e em nove (13,8%) no mais distal. Não se observou diferença significante entre os dois locais de monitorização, quanto à positividade dos índices utilizados. O Índice de Sintomas foi mais eficiente que a Probabilidade de Associação de Sintomas, em relação à capacidade de relacionar as queixas clínicas com o refluxo. Conclusões: 1. Em pacientes selecionados, não há evidências sugestivas de migração do sensor distal de pH para a câmara gástrica; 2. A quantificação do refluxo ácido foi significantemente maior na monitorização mais distal em relação à convencional; 3. A monitorização mais distal não promoveu incremento significante na capacidade de relacionar a queixa clínica com o refluxo, em relação à monitorização convencional e 4. O Índice de Sintomas foi mais eficiente que a Probabilidade de Associação de Sintomas, quanto à capacidade de relacionar a queixa clínica com o refluxo / Background: For conventional gastroesophageal acid reflux monitoring, by pH-metry, a pH sensor is positioned 5cm above the upper edge of the lower esophageal sphincter. However, this appears to not be the ideal position to diagnose reflux disease, seeing as the alterations of the esophageal mucosa, arising due to reflux, mainly occur in the more distal section of the organ and that acid exposure reduces progressively from the distal section toward the proximal esophagus. Aims: to compare two levels of measurement of reflux: the conventional one with a more distal one (3cm above the upper edge of the lower esophageal sphincter) regarding: occurrence of alterations in the tract suggestive of intragastric pH detection, quantification of reflux and relation with the clinical complaints. It further aims to compare two methods of study of the relation between clinical complaints and reflux: Symptom Index and the Symptom-Association Probability. Material and Methods: Patients were studied prospectively, with typical symptoms of reflux disease, submitted to: clinical interview, upper gastrointestinal endoscopy, esophageal manometry and pH-metry with two sensors: a proximal, conventionally positioned, one and a more distal one (3cm above the upper edge of the lower esophageal sphincter). Results: 105 patients were included; 47 (44.8%) with erosive esophagitis, 34 (32.4%) with non-erosive esophagitis and 24 (22.9%) without esophagitis at endoscopic study. There were no alterations in the measurements which would suggest the detection of intragastric pH in any patient. The quantification of reflux was significantly higher in the distal section of the esophagus compared to the proximal, in all of the analyzed parameters: percentage of total time of reflux, percentage of time of reflux in orthostatic position, percentage of reflux in supine position, number of reflux episodes, number of refluxes with duration longer than 5 minutes, duration of the longest reflux episode and DeMeester Score. The Symptom Index was positive in 46 (67.7%) patients in the conventional position and in 49 (72.1%) in the more distal position; the Symptom- Association Probability was positive in 10 (14.4%) patients in the conventional position and in nine (13.8%) in the more distal one. No significant difference was observed between the two monitoring positions, or the positivity of the indices used. The Symptom Index was more efficient than the Symptom-Association Probability, in relation to its capacity to link the clinical complaints with reflux. Conclusions: 1. in selected patients, there was not suggestive evidence of migration of the distal pH sensor to the gastric chamber; 2. The quantification of acid reflux was significantly higher in the more distal compared to the conventional monitoring; 3. The most distal measurement did not promote significant increase in the ability to relate the clinical complaint with reflux, compared to conventional measurement and 4. The Symptom Index was more efficient than the Symptom-Association Probability in the capacity of relating the clinical complaints with reflux
18

Estudo comparativo da mensuração do refluxo gastroesofágico, por pHmetria esofágica prolongada, em dois níveis: a 5 e a 3 cm acima do esfíncter inferior do esôfago / Comparative study of the measurement of gastroesophageal reflux, by prolonged esophageal pH-metry, at two levels: 5 and 3 cm above the lower esophageal sphincter

Jeovana Ferreira Brandão 30 July 2010 (has links)
Racional: Para a monitorização do refluxo ácido gastroesofágico, por pHmetria, convencionalmente, posiciona-se o sensor de pH 5 cm acima da borda superior do esfíncter inferior do esôfago. Porém, esta parece não ser a localização ideal para estabelecer-se o diagnóstico da doença do refluxo, visto que as alterações da mucosa esofágica decorrentes do refluxo ocorrem, principalmente, no segmento mais distal do órgão e que a exposição ácida diminui progressivamente do segmento mais distal do esôfago em direção ao proximal. Objetivos: Comparar dois níveis de mensuração do refluxo: o convencional com um mais distal (3 cm acima da borda superior do esfíncter inferior do esôfago) quanto à: ocorrência de alterações no traçado sugestivas de detecção de pH intragástrico, quantificação do refluxo e relação do mesmo com as queixas clínicas. Objetiva-se ainda, comparar duas modalidades de estudo da relação entre queixa clínica e refluxo: o Índice de Sintomas e a Probabilidade de Associação de Sintomas. Material e métodos: Foram estudados, prospectivamente, pacientes com sintomas típicos da doença do refluxo, submetidos à: entrevista clínica, endoscopia digestiva alta, manometria esofágica e pHmetria com dois sensores de registro: um proximal posicionado na localização convencional e um mais distal (3 cm acima da borda superior do esfíncter inferior do esôfago). Resultados: Foram incluídos 105 pacientes; 47 (44,8%) com esofagite erosiva, 34 (32,4%) com esofagite não-erosiva e 24 (22,9%) sem esofagite ao estudo endoscópico. Não houve alterações no traçado sugestivas de detecção de pH intragástrico em nenhum paciente. A quantificação do refluxo foi significantemente maior no segmento distal do esôfago, em relação ao proximal, em todos os parâmetros analisados: percentagem de tempo total de refluxo, percentagem do tempo de refluxo em posição ortostática, percentagem de refluxo em posição supina, número de episódios de refluxos, número de refluxos com duração maior que 5 minutos, duração do episódio mais longo de refluxo e pontuação de DeMeester. O Índice de Sintoma foi positivo em 46 (67,7%) pacientes no local convencional e em 49 (72,1%) no local mais distal; a Probabilidade de Associação de Sintomas foi positiva em 10 (14,4%) pacientes no local convencional e em nove (13,8%) no mais distal. Não se observou diferença significante entre os dois locais de monitorização, quanto à positividade dos índices utilizados. O Índice de Sintomas foi mais eficiente que a Probabilidade de Associação de Sintomas, em relação à capacidade de relacionar as queixas clínicas com o refluxo. Conclusões: 1. Em pacientes selecionados, não há evidências sugestivas de migração do sensor distal de pH para a câmara gástrica; 2. A quantificação do refluxo ácido foi significantemente maior na monitorização mais distal em relação à convencional; 3. A monitorização mais distal não promoveu incremento significante na capacidade de relacionar a queixa clínica com o refluxo, em relação à monitorização convencional e 4. O Índice de Sintomas foi mais eficiente que a Probabilidade de Associação de Sintomas, quanto à capacidade de relacionar a queixa clínica com o refluxo / Background: For conventional gastroesophageal acid reflux monitoring, by pH-metry, a pH sensor is positioned 5cm above the upper edge of the lower esophageal sphincter. However, this appears to not be the ideal position to diagnose reflux disease, seeing as the alterations of the esophageal mucosa, arising due to reflux, mainly occur in the more distal section of the organ and that acid exposure reduces progressively from the distal section toward the proximal esophagus. Aims: to compare two levels of measurement of reflux: the conventional one with a more distal one (3cm above the upper edge of the lower esophageal sphincter) regarding: occurrence of alterations in the tract suggestive of intragastric pH detection, quantification of reflux and relation with the clinical complaints. It further aims to compare two methods of study of the relation between clinical complaints and reflux: Symptom Index and the Symptom-Association Probability. Material and Methods: Patients were studied prospectively, with typical symptoms of reflux disease, submitted to: clinical interview, upper gastrointestinal endoscopy, esophageal manometry and pH-metry with two sensors: a proximal, conventionally positioned, one and a more distal one (3cm above the upper edge of the lower esophageal sphincter). Results: 105 patients were included; 47 (44.8%) with erosive esophagitis, 34 (32.4%) with non-erosive esophagitis and 24 (22.9%) without esophagitis at endoscopic study. There were no alterations in the measurements which would suggest the detection of intragastric pH in any patient. The quantification of reflux was significantly higher in the distal section of the esophagus compared to the proximal, in all of the analyzed parameters: percentage of total time of reflux, percentage of time of reflux in orthostatic position, percentage of reflux in supine position, number of reflux episodes, number of refluxes with duration longer than 5 minutes, duration of the longest reflux episode and DeMeester Score. The Symptom Index was positive in 46 (67.7%) patients in the conventional position and in 49 (72.1%) in the more distal position; the Symptom- Association Probability was positive in 10 (14.4%) patients in the conventional position and in nine (13.8%) in the more distal one. No significant difference was observed between the two monitoring positions, or the positivity of the indices used. The Symptom Index was more efficient than the Symptom-Association Probability, in relation to its capacity to link the clinical complaints with reflux. Conclusions: 1. in selected patients, there was not suggestive evidence of migration of the distal pH sensor to the gastric chamber; 2. The quantification of acid reflux was significantly higher in the more distal compared to the conventional monitoring; 3. The most distal measurement did not promote significant increase in the ability to relate the clinical complaint with reflux, compared to conventional measurement and 4. The Symptom Index was more efficient than the Symptom-Association Probability in the capacity of relating the clinical complaints with reflux
19

Estudo comparativo de duas modalidades de mensuração do refluxo gastroesofágico: pHmetria esofágica convencional e pHmetria sem cateter / Comparative study of two modes of gastroesophageal reflux measuring: conventional esophageal pH monitoring and wireless pH monitoring

Rimon Sobhi Azzam 02 September 2009 (has links)
A pHmetria esofágica é considerada o melhor método diagnóstico do refluxo ácido gastroesofágico. Contudo, é bastante incômoda e restringe consideravelmente as atividades cotidianas do paciente. A pHmetria sem cateter foi desenvolvida para contornar tais limitações. OBJETIVOS: Comparar as pHmetrias convencional e sem cateter em relação: ao grau de incômodo e limitações das atividades cotidianas, à ocorrência de falhas técnicas relevantes, à capacidade de detecção do refluxo e de relacionar as queixas clínicas com o mesmo. Objetiva-se também, verificar se a monitorização mais prolongada (48 horas) oferece vantagens em relação à monitorização usual (24 horas). MÉTODOS: Foram estudados, de modo prospectivo, 25 pacientes encaminhados para realização de pHmetria esofágica, com sintomas típicos da doença do refluxo gastroesofágico, como queixa predominante. Todos pacientes foram submetidos à entrevista clínica, manometria esofágica e realização, com período inicial simultâneo, de pHmetrias com cateter (24 horas) e sem cateter (48 horas). Foi aplicado questionário para avaliação do grau de incômodo, após o término das pHmetrias. RESULTADOS: Quanto ao incômodo na introdução dos sensores de medida de pH, quinze (60%) pacientes apontaram a cápsula como mais incômoda e dez (40%) o cateter (p=0,327). Durante a monitorização, o incômodo foi menor no segundo dia em relação ao primeiro, em todos os itens do questionário (p<0,05). Houve queda precoce da cápsula em um (4%) paciente e nenhuma falha técnica relevante na pHmetria com cateter (p=0,463). As porcentagens de tempo de refluxo (total, ortostático e supino) foram mais elevadas na pHmetria sem cateter (p<0,05). O Índice de Sintomas foi positivo em 12 (48%) pacientes na pHmetria com cateter e em 13 (52%) na pHmetria sem cateter (p=0,777). O Índice de Sintomas foi positivo em 13 (52%) pacientes na pHmetria por tempo usual (24h) e em 14 (56%) na mais prolongada (48h) (p=1,000). CONCLUSÕES: Nas condições da presente pesquisa: 1) Não há diferença significante entre as duas modalidades de pHmetria, em relação ao grau de incômodo na introdução dos sensores de pH (cápsula X cateter) e nem quanto à ocorrência de falhas técnicas relevantes durante o exame; 2) A monitorização do refluxo pela pHmetria sem cateter é menos incômoda que a com cateter. A pHmetria sem cateter detecta refluxo em porcentagens superiores aos detectados pela pHmetria convencional; 3) Os dois métodos de pHmetria têm capacidades semelhantes de relacionar as queixas clínicas com o refluxo; 4) A monitorização mais prolongada (48h) não proporciona incremento significante na capacidade de relacionar as queixas clínicas com o refluxo, em relação à monitorização por tempo usual (24h). / Esophageal pH monitoring is considered to be the gold standard for the diagnosis of gastroesophageal acid reflux. However, this method is very troublesome and considerably limits the patients routine activities. Wireless pH monitoring was developed to avoid these restrictions. OBJECTIVES: To compare conventional and wireless pH monitoring in relation to: routine activity limitations and degree of discomfort, the occurrence of relevant technical failures, the ability to detect reflux and to correlate the clinical symptoms to it. An additional objective is to determine if longer monitoring (48-hour) offers any advantages over usual monitoring (24-hour). METHOD: Twenty-five patients referred for esophageal pH monitoring and with typical symptoms of gastroesophageal reflux disease as the main complaint were studied prospectively. All patients underwent clinical interview, esophageal manometry and were submitted, with a simultaneous initial period, to 24-hour catheter pH monitoring and 48-hour wireless pH monitoring. After each pH-metry the patients completed a questionnaire on the degree of discomfort. RESULTS: Fifteen (60%) patients reported a higher level of discomfort to introduce the capsule and ten (40%) to introduce the catheter (p=0.327). For all questionnaire items, less discomfort was reported during the second day of monitoring in comparison to the first day (p<0.05). Early capsule detachment occurred in one (4%) case and there were no relevant technical failures with the catheter pH monitoring (p=0.463). Percentages of reflux time (total, upright and supine) were higher with the wireless pH monitoring (p<0.05). The Symptom Index was positive in 12 (48%) patients with catheter pH monitoring and in 13 (52%) with wireless pH monitoring (p=0.777). The Symptom Index was positive in 13 (52%) patients with usual 24-hour pH-metry and in 14 (56%) with longer pH-metry (48-hour) (p=1.000). CONCLUSIONS: Under the conditions of the current research: 1) No significant differences were reported between the two methods of pH monitoring, in relation to the degree of discomfort to introduce the pH sensors (capsule X catheter) or in regard to relevant technical failures; 2) During pH monitoring, the wireless system is better tolerated than the catheter. Wireless pH monitoring detected higher percentages of reflux time than the conventional pH-metry; 3) The two methods of pH monitoring were comparable in correlating the clinical symptoms with the reflux; 4) The longer 48-hour pH monitoring does not significantly improve the ability to correlate the clinical symptoms with the reflux in relation to the 24-hour pH monitoring.
20

Estudo prospectivo comparativo de duas modalidades de posicionamento do sensor de pH-metria esofágica prolongada: por manometria esofágica e pela viragem do pH / Comparative prospective study of two positioning modes of 24-hour esophageal pH monitoring: by esophageal manometry and by the pH step-up technique

Rita de Cassia Frare 18 January 2008 (has links)
Por padronização aceita internacionalmente, posiciona-se o sensor distal de pH-metria esofágica a 5 cm acima da borda superior do esfíncter inferior do esôfago, identificado por manometria esofágica. Porém, vários autores sugerem técnicas alternativas de posicionamento que prescindem da manometria; dentre essas, destaca-se a da viragem do pH. Esse tema é controverso: alguns autores consideram a técnica da viragem confiável, outros afirmam que não é. Considerando-se a polêmica existente e o pequeno número de trabalhos prospectivos com amostra e metodologia adequadas, idealizamos o presente estudo, que tem por objetivos avaliar a adequação do posicionamento do sensor distal de pH-metria baseado na técnica da viragem, analisando-se a presença, o grau e o tipo de erro de posicionamento que tal técnica proporciona e a influência da posição adotada pelo paciente durante a manobra. Foram estudados, de modo prospectivo, 1031 pacientes encaminhados para realização de pH-metria esofágica. Durante entrevista clínica, foram registrados os dados demográficos e as queixas clínicas apresentadas. Todos pacientes foram submetidos à manometria esofágica para localização do esfíncter inferior do esôfago e à técnica da viragem do pH, que consiste na introdução do sensor de pH-metria na câmara gástrica e na tração gradual do mesmo até que o pH vire para níveis superiores a 4. A identificação do ponto de viragem foi realizada de dois modos distintos, caracterizando dois grupos de estudo: com o paciente sentado (Grupo I - 450 pacientes) e em decúbito dorsal horizontal (Grupo II - 581 pacientes). Após a identificação do ponto de viragem, o sensor distal de pH-metria era posicionado na posição padronizada, baseada na localização manométrica do esfíncter. Registrava-se onde seria posicionado o sensor de pH se fosse adotada a técnica da viragem. Para avaliação da adequação do posicionamento, considerou-se que o erro é representado pela diferença (em centímetros) entre a localização padronizada e a localização que seria adotada caso fosse empregada a técnica da viragem. Considerou-se que o erro seria grosseiro se fosse maior que 2 cm. Analisou-se também o tipo de erro mais freqüente: se acima ou abaixo da posição padronizada. Observou-se que se fosse adotada a técnica da viragem, haveria erro no posicionamento do sensor em 945 pacientes (91,6%). Quanto ao grau de erro, haveria erro grosseiro em 597 (63,2%) casos. Em relação ao tipo de erro, o sensor seria posicionado abaixo do local padronizado em 857 (90,7%) pacientes. Em relação à interferência da posição adotada pelo paciente durante a técnica da viragem, observou-se que não houve diferença significante entre os grupos de estudo, em nenhum dos parâmetros analisados. Conclui-se que: 1. o posicionamento do sensor distal de pH-metria pela técnica da viragem não é confiável; 2. a técnica da viragem proporciona margem de erro expressiva; 3. o tipo de erro mais comum que tal modalidade técnica proporciona é o posicionamento mais distal do sensor, que pode superestimar a ocorrência de refluxo; 4. não há influência da posição adotada pelo paciente durante a realização da técnica da viragem do pH, na eficiência do método / By internationally accepted standardization, the esophageal pH-meter distal sensor is positioned 5 cm above the superior border of the esophagus lower sphincter, identified by esophageal manometry. However, several authors suggest alternative positioning techniques that leave out the manometry; among such techniques, the pH step-up is the one to be pointed out. This subject is controversial; some publications state that the step-up technique is not reliable while some others consider it reliable. Considering the existent controversy and the small number of prospective works with suitable sample and methodology, we have idealized the present study, that aims the evaluation of the suitability of the pH-meter distal sensor positioning based on the step-up technique, by analyzing the presence, the degree and the type of the error of positioning that such technique provides and the influence of the position adopted by the patient during the procedure. 1031 patients conducted to the esophageal pH-meter procedure were studied in a prospective way. During the clinical interview, the demographic data and the presented clinical complaints were registered. All the patients were submitted to both esophageal manometry in order to localize the esophagus lower sphincter and the pH step-up technique, that consists of the introduction of the pH-meter sensor in the gastric chamber and in the sensors gradual traction until the pH steps up to levels over 4. The step-up point was identified by two distinct ways, characterizing two study groups: with the setting patient (Group I - 450 patients) and in supine position (Group I I- 581 patients). After the step-up point identification, the pH-meter distal sensor was placed in the standard position, based on the sphincter manometric placement. It was registered where the pH sensor would be positioned if the step-up technique were adopted. To evaluate the positioning suitability, the error was considered to be represented by the difference (in centimeters) between the suitable placement (manometry) and the one that would be adopted in case the step-up technique were adopted. The positioning error was considered rough if it were larger than 2 cm. The most frequent type of error was also analyzed: if above or below the standard position. It was observed that if the step-up technique were adopted, there would be error in the sensor positioning in 945 patients (91.6%). In terms of error degree, there would be a rough error in 597 (63.2%) cases. Concerning the type of error, the sensor would be positioned below the standard place in 857 (90.7%) patients. As to the interference of the position adopted by the patient during the step-up technique, it was observed that there was no significant difference among the groups of study, in any of the analyzed parameters. It was concluded that: 1. the positioning of the pH-meter distal sensor by the step-up technique is not reliable; 2. the step-up technique provides expressive error margin; 3. the most common type of error that such technique mode provides is the placement of the sensor below the standard positioning, which may overestimate the reflux occurrence; 4. there is no influence in the position adopted by the patient during the pH step-up technique procedure, in terms of method efficiency

Page generated in 0.0685 seconds