• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 7
  • Tagged with
  • 7
  • 7
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Interações intermoleculares em compostos derivados da diaminometileno tiouréia.

Gonçalves, Rafael Silva January 2015 (has links)
Programa de Pós-Graduação em Ciências – Física de Materiais. Departamento de Física, Instituto de Ciências Exatas e Biológicas, Universidade Federal de Ouro Preto. / Submitted by Oliveira Flávia (flavia@sisbin.ufop.br) on 2015-05-27T18:51:26Z No. of bitstreams: 2 license_rdf: 22190 bytes, checksum: 19e8a2b57ef43c09f4d7071d2153c97d (MD5) DISSERTAÇÃO_InteraçõesIntermolecularesCompostos.pdf: 2868357 bytes, checksum: 4c20868b67f89d49cc997e9998578af0 (MD5) / Approved for entry into archive by Gracilene Carvalho (gracilene@sisbin.ufop.br) on 2015-05-28T16:54:50Z (GMT) No. of bitstreams: 2 license_rdf: 22190 bytes, checksum: 19e8a2b57ef43c09f4d7071d2153c97d (MD5) DISSERTAÇÃO_InteraçõesIntermolecularesCompostos.pdf: 2868357 bytes, checksum: 4c20868b67f89d49cc997e9998578af0 (MD5) / Made available in DSpace on 2015-05-28T16:54:50Z (GMT). No. of bitstreams: 2 license_rdf: 22190 bytes, checksum: 19e8a2b57ef43c09f4d7071d2153c97d (MD5) DISSERTAÇÃO_InteraçõesIntermolecularesCompostos.pdf: 2868357 bytes, checksum: 4c20868b67f89d49cc997e9998578af0 (MD5) Previous issue date: 2015 / O monocristal de 1-(diaminomethylene)thiouron-1-ium 4-hydroxybenzenesulfonate foi crescido usando a técnica de crescimento em solução. O composto foi caracterizado por espectroscopia FT-IR e difração de raios X. As características das bandas serão discutidas no presente trabalho. O composto foi cristalizado no grupo de espaço P21/c do sistema monoclínico. A conformação do cátion de 1-(diaminomethylene)thiouron-1-ium não é plana mas ligeiramente torcida. Ambos os braços do cátion estão rotacionados opostamente em um ângulo de 8.5(1)o em torno da ligação CN que envolvem o átomo central de nitrogênio N1. O arranjo dos componentes de cargas opostas, o cátion 1-(diaminomethylene)thiouron- 1-ium e o ânion 4-hydroxybenzenesulfonate no cristal são determinados por interações iônicas e ligações de hidrogênio formando uma estrutura supramolecular. ________________________________________________________________________________________ / ABSTRACT: The single crystals of 1-(diaminomethylene)thiouron-1-ium 4-hydroxybenzenesulfonate were grown using a solution growth technique. The compound was characterised by the FTIR spectroscopy and single-crystal X-ray diffraction. The characteristic bands of the functional and skeletal groups of 1-(diaminomethylene)thiouron-1-ium 4- hydroxybenzenesulfonate are discussed. The compound crystallises in the centrosymmetric P21/c space group of the monoclinic system. The conformation of the 1- (diaminomethylene)thiouron-1-ium cation is not strictly planar, but twisted. Both arms of the cation are oppositely rotated by 8.5(1)o around the CN bonds involving the central N atom. The arrangement of oppositely charged components, i.e. 1- (diaminomethylene)thiouron-1-ium cations and 4-hydroxybenzenesulfonate anions in the crystal is mainly determined by ionic and hydrogen-bonding interactions forming supramolecular network.
2

Determinação de Sc e Li em sedimento de rio por ETAAS com emprego de amostragem de suspensão e suas aplicações como possiveis normalizadores de contaminação ambiental

Ribeiro, Araceli Veronica Flores Nardy 04 August 2018 (has links)
Orientadores: Marco Aurelio Zezzi Arruda, Anne Helene Fostier / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Quimica / Made available in DSpace on 2018-08-04T00:16:32Z (GMT). No. of bitstreams: 1 Ribeiro_AraceliVeronicaFloresNardy_D.pdf: 5093368 bytes, checksum: 9ab4f143d2cf959ddbd59895259d9e3e (MD5) Previous issue date: 2004 / Doutorado
3

Potencialidade do vermelho de Alizarina S impregnado em resinas para separação e pré-concentração de Cu, Zn e Mn em matrizes salinas

Santos Junior, Aníbal de Freitas January 2001 (has links)
Submitted by Edileide Reis (leyde-landy@hotmail.com) on 2013-04-23T10:54:16Z No. of bitstreams: 1 Santos Junior.pdf: 519489 bytes, checksum: a1719f6277c1103b392d18a0b0d03303 (MD5) / Made available in DSpace on 2013-04-23T10:54:16Z (GMT). No. of bitstreams: 1 Santos Junior.pdf: 519489 bytes, checksum: a1719f6277c1103b392d18a0b0d03303 (MD5) Previous issue date: 2001 / A determinação de elementos traços por Espectrometria de Absorção Atômica com atomização por chama (FAAS) em matrizes com alto teor salino, tais como água do mar e salmouras, é limitada devido a vários fatores, principalmente a baixa concentração dos metais e a alta concentração de eletrólitos. Portanto, procedimentos de separação e pré-concentração são necessários. O objetivo deste trabalho foi avaliar as potencialidades de duas fases sólidas obtidas por impregnação de uma resina não-iônica Amberlite XAD?7 e uma resina aniônica Dowex 1X8-50 com o reagente Vermelho de Alizarina S para separação e pré-concentração de manganês, cobre e zinco em matrizes salinas. Vários parâmetros experimentais foram estudados tais como pH, tempo de agitação, capacidade de sorção, natureza e concentração de eluente e efeito de concomitantes. Para o sistema XAD-7/VAS, Mn, Cu e Zn são quantitativamente retidos, na faixa de pH de 8,5 a 10,0, para uma massa de 0,50 g da fase sólida, após 5 minutos de agitação mecânica e uma massa total de até 200 mg de cada metal. Os elementos são eluídos com 5 mL de HNO3 3 mol.L-1, com recuperação ³ 95%, obtendo-se fator de pré-concentração de até 50 vezes para Zn e de 10 vezes para Mn e Cu. Para o sistema Dowex 1X8-50/VAS, Cu e Mn foram quantitativamente retidos, na faixa de pH de 8,1 a 9,0 e Zn em pH 8,1, usando uma massa de 0,75 g da fase sólida, após 90 minutos de agitação mecânica e uma massa total de até 50 mg de cada metal. Os elementos são eluídos com 20 mL de HNO3 2 mol.L-1, obtendo-se fator de pré-concentração de até 5 vezes para Cu e Zn. As metodologias propostas foram aplicadas na determinação de Mn, Cu e Zn em solução fisiológica e água do mar, da cidade de Salvador/BA. Testes de recuperação com adição de 5 mg dos metais às amostras revelaram eficiência no que diz respeito à exatidão e a precisão dos procedimentos propostos, com retenção quantitativa maior ou igual a 95%. / Salvador
4

Desenvolvimento de procedimentos alternativos de Preparo e de determinação de metais pesados em fármacos tricíclicos

Barin, Juliano Smanioto 24 August 2007 (has links)
In this work, sample preparation and determination methods described in pharmacopeias were evaluated and alternative methods using sample decomposition in closed vessels and determination by atomic spectrometrometry were proposed as alternative. Tricyclic drugs (carbamazepine, amitryptyline hydrochloride and imipramine hydrochloride) were used to evaluate the methods. Pharmacopeial methods showed poor results for both sample preparation and determination methods. Many elements were lost during the decomposition in a muffle furnace and an incomplete decomposition was observed by wet digestion. For determination, the precipitation of analytical solutions of Ag, As, Bi, Cd, Cu, Hg, Mo, Pb, Sb and Sn with sulfide ion were suitable only for Ag and Pb. Therefore, some methods of sample preparation and heavy metals determination were evaluated. The microwave-induced combustion (MIC) with 7 mol L-1 HNO3 as absorbing solution was suitable for all elements with recoveries between 80 and 110%. The wet digestion of carbamazepine samples with HNO3 using the high pressure asher system (HPA) was efficient only at 320 °C by 3 h. If lower temperatures in HPA or microwave-assisted disgestion systems were used a incomplete digestion was obtained with a residue formation. These residues were caracterized by UV, HPLC, IV and RMN (1H and 13C) and a nitrated tricyclic structure could be pointed out. For amitryptyline hydrochloride and imipramine hydrochloride samples the dilution in water or diluted HNO3 was suitable for determination of heavy metals by GF AAS, ICP-OES and ICP-MS. However, for carbamazepine samples only two possibilities were found: the decomposition by MIC and determination by ICP-MS or the determination by directly solid sampling GF AAS. / Neste trabalho os métodos farmacopéicos de preparo de amostras e de determinação de metais pesados foram avaliados e novos métodos de preparo de amostras em sistemas fechados e determinação de metais pesados por espectrometria atômica são propostos como alternativa. Para tanto, amostras de fármacos tricíclicos (carbamazepina, cloridrato de amitriptilina e cloridrato de imipramina) foram utilizadas. Os métodos farmacopéicos mostraram-se inadequados tanto para o preparo quanto para a determinação de metais pesados. Na decomposição em mufla vários elementos foram perdidos por volatilização enquanto que na decomposição por via úmida a decomposição foi incompleta. Já nos ensaios de determinação de metais pesados por precipitação com íon sulfeto, resultados satisfatórios para soluções analíticas de Ag, As, Bi, Cd, Cu, Hg, Mo, Pb, Sb e Sn foram encontrados apenas para Ag e Pb. Desta forma, novos procedimentos de preparo de amostras e determinação de metais pesados foram estudados. A decomposição por combustão iniciada por microondas (MIC) mostrou-se adequada para todos os elementos estudados empregando HNO3 7 mol L-1 como solução absorvedora, com recuperações entre 80 e 110%. Já a decomposição das amostras por via úmida com HNO3 em sistema fechado em alta temperatura e pressão (HPA) foi eficiente para carbamazepina apenas na temperatura de 320 °C por 3 horas. A decomposição em temperaturas inferiores ou a utilização de sistemas de decomposição assistidos por microondas foi ineficiente, com a formação de uma grande quantidade de resíduo após aquecimento. Para tentar compreender a formação dos resíduos da decomposição por via úmida, foi efetuada a caracterização dos mesmos por UV, HPLC, IV e RMN de 1H e 13C, evidenciando a formação de um composto tricíclico nitrado. Para as amostras de cloridrato de amitriptilina e cloridrato de imipramina, a solubilização direta em água ou HNO3 diluído foi suficiente para as determinações por GF AAS, ICP-OES e ICP-MS para os elementos estudados. Já para carbamazepina, a única alternativa foi a decomposição por MIC, seguida da determinação por ICP-MS, ou através da análise dirata de amostras sólidas por GF AAS.
5

Determinação de Fe, Cu, Mn, Ni, V e Ti em partículas totais em suspensão coletadas em uma área urbana da cidade de Aracaju, Sergipe

Almeida, Tarcísio Silva de 27 February 2012 (has links)
This study aimed to determine and assess the total concentration of trace elements associated with the total suspended particles (TSP) collected in an urban area of the Aracaju City, Sergipe, Brazil. Forty two samples were collected on glass fiber filters between period August/2009 and September/2010 using a high volume sampler (AGV). The concentration of Fe, Cu, Mn, Ni, V and Ti were determined employing atomic spectrometry techniques in two different work. The first used acid digestion extraction assisted by microwave and analysis by mass spectrometry and optical emission, both inductively coupled plasma (ICP OES and ICP MS). The concentrations of the elements found between <48 and 1620 ± 16 ng.m-3 for Fe; 0.70 ± 0.04 and 322 ± 4 ng.m-3 for Cu;<1,3 and 12.7 ± 6.8 ng.m-3 for Mn; 1.1 ± 0.1 and 16.0 ± 8.4 ng.m-3 for Ni; <15 and 49.3 ± 4.0 ng.m-3 for V and 4,6 ± 0,6 a 129,0 ± 12,5 ng.m-3 for Ti (n=41 samples). The exploratory data analysis results was applied. Principal component analysis (PCA) and hierarchical cluster analysis (HCA) concluded that there are two emitters that contribute to the composition of the PTS that reach the sampling area. Soil resuspension is major contributor in the composition due to correlation between Fe, Mn, Ni and Ti, which are typical elements of the soil. The second emitter, is characteristic of the vehicular traffic. wherein the concentration of Cu, V, SO2 and smoke were likely indicative of action anthropogenic. The enrichment factor calculated for the concentration of the elements identified enrichment for the average concentration of copper found in the urban area, is another indication of anthropogenic inputs. The second study consisted of the Cu and Fe sequential determination in TSP using slurry sampling flame atomic absorption spectrometry and mode fast sequetial (FS-FAAS). The optimization univariate involved the following variables: the concentration of nitric acid used to prepare the slurry, sonication time and the sample mass. The optimized conditions, to about 50 mg of sample were: nitric acid solution 0.5 mol L-1, sonication time of 10 min and a final volume of 25 mL. The calibration curves were obtained using a slurry of a non-filter, the pattern multielement containing Cu and Fe in nitric acid 0.5 mol L-1. This strategy calibration offset the effect observed for the matrix Fe The limit of detection (LOD, 3σ, n = 10) was equal 4 μg.g-1 for Cu and 14 μg.g-1 for Fe , corresponding to 8 ng.m-3 for Cu and 20 ng.m-3 for Fe. The precison was expressed as relative standard deviation (RSD, n = 3) was smaller than 7% for the copper concentration and 8% for iron concentration in the slurries analysis (n=3). The concentrations of both elements determined by the proposed method were compared to concentrations obtained by ICP-MS after acid extraction assisted by microwave and showed no significant differences, applying the t test for a confidence level of 95%. The proposed procedure was simple, fast and reliable suitable for the sequential determination of Cu and Fe in PTS samples by FS-FAAS. / Este trabalho teve como objetivo determinar e avaliar a concentração total de elementos traço associados as partículas totais em suspensão (PTS) coletadas em uma área urbana da cidade de Aracaju, Sergipe, Brasil. Quarenta e duas amostras foram coletadas em filtros de fibra de vidro no período entre agosto/2009 e setembro/2010 utilizando um amostrador de grande volume (AGV). As concentrações de Fe, Cu, Mn, Ni, V e Ti foram determinadas empregando-se técnicas de espectrometria atômica em dois trabalhos distintos. O primeiro usou a digestão ácida assistida por micro-ondas e análise por espectrometria de massa e de emissão óptica, ambas com plasma indutivamente acoplado (ICP-MS e ICP OES). Foram encontradas as concentrações entre <48 a 1620 ± 16 ng g-1 para Fe; 0,70 ± 0,04 a 322 ± 4 ng.m-3 para Cu; 1,3 a 12,7 ± 6,8 ng.m-3 para Mn; 1,1 ± 0,1 a 16,0 ± 8,4 ng.m-3 para Ni, <15 a 49,3 ± 4,0 ng.m-3para V e 4,6 ± 0,6 a 129,0 ± 12,5 ng.m-3. Foi aplicada a análise exploratória de dados aos resultados. A partir da análise de componentes principais (PCA) e a análise de agrupamentos hierárquicos (HCA) concluiu-se que há dois emissores que contribuem na composição do PTS que atingem a área amostral. A ressuspensão do solo é o maior contribuidor na composição química, devido correlação encontrada entre Fe, Mn, Ni e Ti, que são elementos tipicos do solo. O segundo emissor é caracteristico do trafego veicular, onde a concentração de Cu, V, SO2 e Fumaça foram prováveis indicativos de ação antropogênica. O fator de enriquecimento calculado para a concentração dos elementos identificou o enriquecimento para a concentração de cobre encontrada na área urbana, sendo outro indicativo da ação antropogênica. O segundo trabalho consistiu da determinação sequencial de Cu e Fe no PTS usando amostragem em suspensão e espectrometria de absorção atômica com chama no modo seqüencial rápido ( fast sequential ) multi-elementar (FS-FAAS). A otimização univariada envolveu as seguintes variáveis: concentração da solução de ácido nítrico usada no preparo da suspensão, tempo de sonicação e massa da amostra. As condições otimizadas, para cerca de 50 mg de amostra, foram: solução de ácido nítrico 0,5 mol.L-1, tempo de sonicação de 10 min e um volume final de 25 mL. As curvas de calibrações foram obtidas, usando-se uma suspensão de um filtro não utilizado, contendo o padrão multielementar de Cu e Fe em meio de ácido nítrico 0,5 mol.L-1. Esta estratégia de calibração compensou o efeito de matriz verificado para o Fe. O limite de detecção (LD, 3σ, n=10) do método proposto foi igual a 4 μg.g-1 para Cu e igual a 14 μg.g-1 para Fe, que corresponde a 8 ng.m-3 para Cu e a 20 ng.m-3 para Fe. A precisão, expressa como o desvio padrão relativo (RSD, n=3), foi menor do que 7% para a concentração de Cu e a 8% para a concentração de Fe na análise das suspensões. As concentrações de ambos os elementos determinados pelo método proposto foram comparadas com as concentrações obtidas por ICP-MS após extração ácida assistida por micro-ondas e não apresentaram diferenças significativas, aplicando-se o teste t para um nível de confiança de 95%. O procedimento proposto é simples, rápido e confiável, adequado para a determinação sequencial de Cu e Fe em amostras de PTS por FS-FAAS.
6

Planejamento de experimento empregado na otimização de métodos analíticos para a determinação de macronutrientes, micronutrientes e elementos traço em fertilizantes minerais por espectometria atômica

Souza, Sidnei de Oliveira 24 July 2014 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / In this work were applied experimental designs to the optimization of analytical methods using atomic spectrometry. Firstly, simultaneous experimental designs were applied to the optimization of two analytical methods, being the first analytical method for the simultaneous determination of macronutrients (Ca, Mg, Na and P), micronutrients (Cu, Fe, Mn and Zn) and trace elements (Al, As, Cd, Pb and V) and other for the simultaneous determination of Th and U in mineral fertilizers, both employing inductively coupled plasma optical emission spectrometry (ICP OES). The results of the analysis of mineral fertilizers showed that the elements regulated by Ministry of Agriculture, Livestock and Food Supply (Ministério da Agricultura, Pecuária e Abastecimento MAPA) were in agreement with the same, and that the high resolution ICP OES allowed to selectivity possible interfering Ca, Fe and Th in the determination of U, indicating that can be performed simultaneous determination of Th and U by technique. In the second part, univariate designs were applied to the optimization of two analytical methods using direct solid sampling (SS) and detection by high resolution continuum source graphite furnace atomic absorption spectrometry (HR-CS GF AAS), one for the determination of Cu and other for Hg in phosphate fertilizers. The results showed that simple superphosphate and triple superphosphate 2 fertilizers samples obtained concentrations of Hg above the maximum limit established by MAPA, as well showed the highest concentrations of Cu, however this is not regulated. The analytical methods proposed in this work were simple, efficient, fast, accurate and reliable for the determination of macronutrients, micronutrients and trace elements in mineral fertilizers by atomic spectrometry. / Neste trabalho foram aplicados planejamentos de experimentos para a otimização de métodos analíticos utilizando a espectrometria atômica. Primeiramente, foram aplicados planejamentos simultâneos para a otimização de dois métodos analíticos, sendo o primeiro método analítico para a determinação simultânea de macronutrientes (Ca, Mg, Na e P), micronutrientes (Cu, Fe, Mn e Zn) e elementos traço (Al, As, Cd, Pb e V), e outro para a determinação simultânea de Th e U em fertilizantes minerais, ambos empregando espectrometria de emissão óptica com plasma acoplado indutivamente (ICP OES). Os resultados das análises de fertilizantes minerais demonstraram que os elementos regulamentados pelo Ministério da Agricultura, Pecuária e Abastecimento (MAPA) estavam de acordo com a mesma, e que a alta resolução do ICP OES permitiu a seletividade dos possíveis interferentes Ca, Fe e Th na determinação do U, indicando que pode ser realizada a determinação simultânea de Th e U pela técnica óptica. Na segunda parte, foram aplicados planejamentos univariados para a otimização de dois métodos analíticos utilizando análise direta de sólidos (SS) e detecção por espectrometria de absorção atômica de alta resolução com fonte contínua e atomização em forno de grafite (HR-CS GF AAS), um para a determinação de Cu e o outro para Hg em fertilizantes fosfatados. Os resultados mostraram que as amostras de fertilizantes superfosfato simples e superfosfato triplo 2 obtiveram concentrações de Hg acima dos limites máximo estabelecidos pelo MAPA, bem como apresentaram as maiores concentrações de Cu, porém este não é regulamentado. Os métodos analíticos propostos neste trabalho foram simples, eficientes, rápidos, exatos e confiáveis para a determinação de macronutrientes, micronutrientes e elementos traço em fertilizantes minerais por espectrometria atômica.
7

Desenvolvimento de estratégias analíticas para determinação de cádmio e chumbo em amostras de água de refinaria e especiação de arsênio e antimônio em amostras de alimentos

Ferreira, Hadla Sousa January 2009 (has links)
146f. / Submitted by Ana Hilda Fonseca (anahilda@ufba.br) on 2013-04-03T13:18:57Z No. of bitstreams: 1 Tese Hadla S Ferreira.pdf: 1335067 bytes, checksum: d1c32c23138aa8d7c8145b340260a496 (MD5) / Approved for entry into archive by Ana Hilda Fonseca(anahilda@ufba.br) on 2013-04-23T15:10:36Z (GMT) No. of bitstreams: 1 Tese Hadla S Ferreira.pdf: 1335067 bytes, checksum: d1c32c23138aa8d7c8145b340260a496 (MD5) / Made available in DSpace on 2013-04-23T15:10:36Z (GMT). No. of bitstreams: 1 Tese Hadla S Ferreira.pdf: 1335067 bytes, checksum: d1c32c23138aa8d7c8145b340260a496 (MD5) Previous issue date: 2009 / CAPES / Neste trabalho, foram desenvolvidos métodos para determinação de cádmio e chumbo em amostras ambientais e antimônio e arsênio em amostras de alimentos, utilizando técnicas de espectrometria atômica. A determinação do cádmio e do chumbo foi realizada através de um sistema de injeção em fluxo acoplado a técnica TS FF AAS. Os íons de cádmio (II) e chumbo (II) foram retidos em uma mini-coluna de Amberlite de XAD – 7 impregnada com ditizona. O planejamento Box- Behnken foi empregado para determinação das condições ótimas da etapa de concentração do chumbo e do cádmio. Os limites de detecção foram de 0,012 e 0,34 μg L-1 para cádmio e chumbo, respectivamente. O método foi aplicado em amostras de resíduos de refinaria de petróleo. A exatidão foi confirmada por análise da CRM NIST 1643d. Foi também desenvolvido um método para determinação de espécies tóxicas de arsênio e antimônio em amostras de alho e cogumelos, respectivamente por HG AFS. A determinação das espécies (III) e (V) de arsênio e antimônio foram baseadas na eficiência de geração de hidreto empregando NaBH4, com e sem uma prévia redução com KI, usando equações proporcionais correspondentes para as duas condições de medida. Os analitos foram extraídas com ácido sulfúrico nas condições de 1,0 e 0,5 mol L-1 para arsênio e antimônio, respectivamente. Com o método desenvolvido obteve-se limites de detecção de 0,6, 1,1, 0,84 e 1,4 ng g-1 para Sb(III), Sb(V), As(III) e As(V), respectivamente. A exatidão do método foi confirmada através de testes de adição e recuperação das espécies bem como, um material de referência certificado NIST 1573a. Um método para determinação de arsênio total em vinho também foi desenvolvido. O arsênio foi determinado por FI-HG AAS com um sistema de atomização eletrotérmica. O planejamento Box-Behnken foi utilizado na determinação das condições ótimas para geração de hidreto. Com método proposto obteve um limite de detecção de 0,06 μg L-1 e foi aplicado em 20 amostras de vinhos comercializadas do Brasil. / Salvador

Page generated in 0.1085 seconds