• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 44
  • 3
  • 3
  • 3
  • 3
  • 2
  • Tagged with
  • 44
  • 44
  • 44
  • 14
  • 14
  • 8
  • 7
  • 7
  • 7
  • 6
  • 6
  • 6
  • 6
  • 5
  • 5
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Caracterização elementar de filtros de alumínio de equipamentos de raios X odontológicos intrabucais

França, Alana Caroline 19 February 2014 (has links)
A busca pela qualidade radiográfica com a menor dose de radiação absorvida é uma constante na comunidade radiológica. Juntamente com o princípio ALARA (As Low As Reasonably Achievable), os filtros de alumínio são peças fundamentais para barrar os fótons de baixa energia que não contribuem para a imagem e depositam dose de radiação para o paciente. De acordo com a Portaria n°453, a Agência Nacional de Vigilância Sanitária decretou que todos os equipamentos de raios X odontológicos intrabucais devem possuir a filtração adicional. Nesse sentido, os filtros são peças fundamentais para a proteção radiológica do paciente. Este estudo tem por objetivo caracterizar a composição elementar dos filtros de raios X de equipamentos de raios X odontológicos intrabucais. O estudo também relaciona a composição elementar com a qualidade das imagens radiográficas. A análise dos filtros foi realizada por meio do método de Espectroscopia de Fluorescência de raios X por Energia Dispersiva (EDXRF). Foram analisados, qualitativa e quantitativamente, dez filtros de alumínio. Para avaliar a qualidade das imagens, foram realizadas 30 radiografias periapicais dos dentes molares com 0,3 s de tempo de exposição (dez radiografias) e incisivos com 0,2 s e 0,3 s (vinte radiografias) com os diferentes filtros em um equipamento com os parâmetros de 66 kV e 6,5 mA. Os filtros e as radiografias foram identificadas, para que fosse possível distinguir a que filtro cada radiografia pertencia no momento das avaliações. Todas as radiografias foram feitas sob as mesmas condições. As radiografias foram submetidas à análise das densidades óticas por um densitômetro e posteriormente, enviadas a cirurgiões dentistas radiologistas que fizeram a análise subjetiva. Foram selecionadas três regiões para análise do densitômetro (diferenciadas entre dentes molares e incisivos) e uma região para análise subjetiva (diferentes regiões para dentes molares e incisivos). Os dados obtidos foram correlacionados com a avaliação dos efeitos da composição elementar dos filtros na qualidade das imagens radiográficas. Os elementos encontrados na análise dos filtros foram: Al, S, Cl, Ti, Mn, Fe, Cu, Zn e Zr. Os filtros apresentaram maiores concentrações de alumínio, com mais de 96% sendo os outros elementos contaminantes ou elementos que foram adicionados para melhorar a estabilidade mecânica do filtro. As densidades óticas das radiografias seguiram um padrão nas regiões analisadas, exceto as regiões enegrecidas do filme. A análise subjetiva revelou que muitas das radiografias realizadas poderiam ser aceitas para diagnóstico. Porém, imagens consideradas com baixo contraste obtiveram o mesmo valor de densidade ótica. Os resultados mostraram que a composição elementar dos filtros não modificou a qualidade da imagem. Por conseguinte, os filtros convencionais pesquisados oferecem uma opção aceitável para a produção de imagens de qualidade em radiologia odontológica, apesar das diferenças na composição das ligas. / The quest for radiographic quality with the lowest dose of radiation absorbed is a constant in the radiology community. Along with the ALARA principle (As Low As Reasonably Achievable), the aluminum filters are essential parts to bar the low energy photons do not contribute to the image and cause radiation dose to the patient. According to standard Portaria No. 453, the Agência Nacional de Vigilância Sanitária decreed that all equipment intraoral dental X-rays must have an additional filtration. Acording this, the filters are essential parts to radiological protection of patients. This study aims to characterize the elemental composition of filters used in intraoral X-ray equipment. We also intend to relate them to the quality of the radiographic images. The analysis of the filters was made using the method Energy Dispersive X-ray Fluorescence (EDXRF). Ten aluminum filters were analyzed (qualitatively and quantitatively). To evaluate the quality of images, 30 periapical radiographs of molars to 0.3 s (ten radiographs) and the incisor teeth 0.2 and 0.3 s (twenty radiographs) were performed with different filters. All filters and all radiographs were identified, it was possible to distinguish which folder each radiograph belonged at the time of the evaluations. All radiographs were performed under the same conditions. Radiographs were subjected to analysis of optical density by a densitometer and later, two dentists radiologists realized a subjective analysis. Three regions for analysis of the densitometer (differentiated between molars and incisors) and a region for subjective analysis (for different regions molars and incisors) were selected. The data were correlated with the assessment of the effects of the elemental composition of all filters in the quality of radiographic images. From the results, the elements of the filters in the analysis were: Al, S, Cl, Ti, Mn, Fe, Cu, Zn and Zr. The filters had higher aluminum concentrations (over 96%), other elements were contaminants or components that are added to improve the mechanical stability of the filter. The optical densities of radiographs followed a pattern for the regions analyzed except blackened regions of the film. Subjective analysis revealed that many of the radiographs were accepted for diagnosis. But considered low-contrast images obtained the same value of optical density. Therefore, it is concluded that the elemental composition of filters do not change the image quality. Consequently, conventional filters were evaluated option to produce an acceptable image quality in dental radiology, despite differences in the composition of the alloys.
42

Estudo da aplicação da técnica de ED-XRF para caracterização elementar de tecidos mamários

Castilho, Priscila Resmer 27 August 2014 (has links)
CAPES / O câncer de mama deve atingir cerca de 57.120 novos pacientes no Brasil em 2014, como divulgado pelo serviço de epidemiologia do Instituto Nacional de Câncer. Pesquisadores têm associado neoplasias mamárias às alterações nas concentrações de alguns elementos no tecido da mama, tais como: cálcio, ferro, cobre e zinco. Neste sentido a técnica de espectroscopia por fluorescência de raios X surge como uma ferramenta para caracterização elementar deste tipo de tecido. A eficácia da referida técnica é fortemente dependente do espectro de raios X incidente na amostra, bem como do procedimento de calibração do sistema de medição. Neste trabalho foi avaliada a influência dos filtros de alumínio na eficiência de medição das concentrações dos elementos atrelados à neoplasias mamárias e avaliação das concentrações mínimas que o equipamento do Laboratório de Física Nuclear Aplicada da Universidade Tecnológica Federal do Paraná é capaz de registrar. O equipamento sobe investigação foi o da Amptek composto por um kit de um tubo de raios X modelo Mini-X e um detector do modelo X-123SD. Dos resultados, observou-se que para a quantificação dos referidos elementos simultaneamente, o uso de filtros de Al com espessura de 0,25 mm proporciona melhor eficácia na excitação dos mesmos. Além disso, foi verificado que são necessárias curvas de calibração específicas para cada elemento, as quais foram obtidas com cinco padrões biológicos da Agência Internacional de Energia Atômica. Os resultados permitiram comparar as concentrações dos padrões certificados aos obtidos pelos cálculos, assim como quantificar duas amostras de tecido mamário de características neoplásicas. / Breast cancer can reach around 57.120 new cases in Brazil in 2014, according the service of epidemiology in the National Cancer Institute. Researchers have been associated mammary neoplasm with changes of elements concentrations such as: calcium, iron, copper and zinc. In this way the technique of X-Ray Fluorescence appears like a tool to characterize this kind of neoplasm. The effectiveness of this technique is strongly dependent of X-ray spectrum incident on the sample as well as the calibration procedure of the measuring system. In present work, were evaluated the influence of aluminum filters on the measurement efficiency of the concentrations of the elements changed in mammary neoplasm and to evaluate the minimum concentrations that the equipment of the Laboratory of Applied Nuclear Physics at Federal University of Technology – Paraná is capable to register. The equipment under study was the Amptek kit of X-ray tube Mini-X and detector X-123SDD. The results obtained shown a simultaneous analysis, in that Al filters with thicknesses of 0.25 mm provides the best efficiency. Besides, it was verified that specifics calibration curves for each element was required, and it were obtained with five biological standards of International Atomic Energy Agency. The results made possible to compare the concentration of biological standards certificates with the equation obtained, in addition to analyze quantitatively two sample of breast tissue.
43

Utilização da espectroscopia PIXE na avaliação do mecanismo de biossorção dos íons Cu²+, Zn²+ e Cd²+ pela macrófita Egeria densa / Study of biosorption mechanism of Cu²+, Zn²+ and Cd²+ by Egeria densa macrophyte using pixe spectroscopy

Santos, Gustavo Henrique Fidelis dos 16 February 2012 (has links)
Made available in DSpace on 2017-07-10T18:08:21Z (GMT). No. of bitstreams: 1 Gustavo H F dos Santos.pdf: 2924329 bytes, checksum: 74a03389110637af2cd08afee90b23ec (MD5) Previous issue date: 2012-02-16 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The main objective of this study was to evaluate the types of biosorption mechanisms involved in the removal of copper, zinc and cadmium divalent ions by dead Egeria densa macrophyte biomass. Batch adsorption experiments, consisting of mixtures of 0.3 g biomass and 50 mL metal solution were performed at initial pH 5, and under constant temperature (50 oC) and shaking conditions. The PIXE analytical technique was applied to determine the metal concentration in aqueous and solid phases. All PIXE measurements were performed at the Ion Beam-based Material Analysis Laboratory of the Physics Institute of the São Paulo University. Preliminary to adsorption experiments, the point of zero charge assigned to E. densa biosorbent was determined to be at a 5.0-6.5 pH value range. From metal speciation diagrams, the Cu, Zn, Cd and Ca divalent ions are expected to be majorities below the pH values of 5, 6, 8, and 10, respectively, whereas above these pH regions other metal compounds are mainly expected. As confirmed by measured pH values of 5.0 ± 0.2 at all experiments of adsorption and desorption, E. densa biosorbent submerged in each metal solution has exhibited zero net electrical charge on its surface, indicating that the removals of Cu²+, Zn²+, and Cd²+ and the desorption of these metal ions should be mainly performed by the ion exchange mechanism. According to the mass balance analysis performed for each metal adsorption experiment, the ion exchange process was confirmed to be the main mechanism for the metal removal and desorption by the E. densa biosorbent. At pH value of 5 the E. densa biosorbent surface shows a behavior of ion exchanger. / O objetivo principal deste trabalho foi avaliar os mecanismos de biossorção envolvidos na remoção dos íons cobre, zinco e cádmio pela macrófita aquática Egeria densa inativa. Experimentos de sorção monocomponente foram realizados em sistema batelada, misturando 0,3 g do biossorvente com 50 mL de solução metálica, com pH inicial 5,0, sob agitação constante e temperatura controlada em 30°C, em uma incubadora refrigerada com agitação. A determinação da concentração das espécies iônicas nas fases líquida e sólida foi realizada pela técnica espectroscópica PIXE (Particle Induced X-ray Emission). As medidas foram realizadas no Laboratório de Análise de Materiais por Feixes Iônicos do Instituto de Física da USP. Foram realizados experimentos para determinação do ponto de carga zero (pHPCZ) da biomassa e elaborados diagramas de especiação dos metais. O pHPCZ da macrófita Egeria densa foi encontrado na faixa entre 5,0 a 6,5. Por meio de diagramas de especiação, observou-se que as formas iônicas Cu²+, Zn²+, Cd²+ e Ca²+ são predominantes nas faixas de pH entre 0 - 5,0; 0 - 5,0; 0 - 8,0 e 0 - 10,0, respectivamente. O pH final medido em todos experimentos de biossorção e de regeneração da biomassa, foi em média de 5,0 ± 0,2. Desta forma, nos experimentos de sorção, os íons cobre, zinco, cádmio e cálcio encontravam-se na forma divalente. Nas condições operacionais utilizadas, a biossorção dos íons metálicos cobre, cádmio e zinco, pela macrófita Egeria densa, em pH inicial 5,0, ocorreu principalmente pelo mecanismo de troca iônica, com os cátions cálcio, sódio e potássio. Na regeneração da macrófita utilizando solução de CaCl2, também foi verificado que o mecanismo envolvido neste processo foi de troca iônica. O processo de dessorção dos íons metálicos ocorreu, devido ao comportamento da biomassa ser equivalente a de um trocador iônico.
44

Filmes nanométricos obtidos a plasma da mistura ácido cítrico-etilenoglicol-metal complexador /

Cavalini, Eliseu Antonio. January 2016 (has links)
Orientador: Rogério Pinto Mota / Coorientador: Elson de Campos / Banca: Maurício Antonio Algatti / Banca: Roberto Yzumi Honda / Banca: Emerson Ferreira de Lucena / Banca: Nazir Monteiro dos Santos / Resumo: Plasmas de gases e / ou vapores orgânicos produzem filmes finos ou pós apresentando características poliméricas, especialmente quando os plasmas são derivados de monômeros das famílias dos hidrocarbonetos alcoóis, siloxanos, silazanos, e outro. Neste trabalho, os filmes finos foram obtidos a partir da mistura de ácido cítrico-etilenoglicol-metal complexador depositado a plasma, com 13,56 MHz de radiofrequência na potência de 10 a 50 W e pressão fixada a 10 Pa. Os resultados da análise de espectroscopia de infravermelho FTIR mostrou que os grupos vibracionais dos filmes estavam preservados, mas com modificações em suas estruturas moleculares. Foram observados nos resultados obtidos por espectroscopia fotoelétrica de raios-X modificações na composição química da ligação oxigênio-carbono e oxigênio-hidrogênio com variação da potência de 10 a 50 W. A taxa de deposição dos filmes finos diminuiu de 0,10 a 0,08 nm/minuto com o aumento da potência de 10 a 50 W. As propriedades óticas das amostras como o índice de refração, coeficiente de absorção, gap ótico foram investigados por espectroscopia UV- visível. Destas análises foram possíveis obter valores n de 1,54 a 1,50 e energia do gap entre 4,75 e 4,85 eV. A técnica de ângulos de contato e foi utilizada para investigar a molhabilidade das amostras, que apresentaram caráter hidrofílico em todas as condições de deposição dos filmes. A técnica de EDS foi usada para investigar as composições químicas das amostras. Além disso, os filmes ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Plasmas from gases and / or organic vapors produce thin films or powders presenting polymeric characteristics, especially when the plasmas are derived from monomers of the families of hydrocarbons, alcohols, siloxanes, silazanes, and others. In this work, thin films were obtained by citric acid / ethylene glycol / complex metal deposited by 13.56 MHz RF plasma at 10 and 50 W fixed pressure 10 Pa. FTIR spectroscopy showed that the main vibrational groups of the films were preserved, but with modifications in their molecular structures. It was observed by X -ray photoelectron spectroscopy chemical composition modifications in oxygen - carbon and oxygen - hydrogen bond while the deposition power changed from 10 to 50 W. The deposition rate of the samples decreased from 0.10 to 0.08 nm / minute while the RF power increases from 10 to 50 W. The samples optical properties as refractive index n, absorption coefficient, optical gap Eg were investigated by UV - Visible spectroscopy. From these analysis were possible to obtain values of n from 1.54 to 1.50 and Eg between 4.75 and 4.85 eV. Contact angle and surface energy measurements were used to investigate the wettability of composite Polymer films, for all depositions conditions the films presented hydrophilic character. EDS was used investigate components of the samples. Moreover, the film showed electrical conductivity values greater than 10-8 (Ωcm)-1 and dielectric constant between 2.2 and 2.7 / Doutor

Page generated in 0.1022 seconds