Spelling suggestions: "subject:"estabilidade dde taludes"" "subject:"estabilidade dee taludes""
51 |
[en] DISCUSSION ON PROBABILISTIC ANALYSIS OF SLOPE STABILITY / [es] CONSIDERACIONES SOBRE EL ANÁLISIS PROBABILÍSTICO DE LA ESTABILIDAD DE TALUDES / [pt] CONSIDERAÇÕES SOBRE ANÁLISE PROBABILÍSTICA DA ESTABILIDADE DE TALUDESMARIA CECILIA SAFADY GUEDES 05 September 2001 (has links)
[pt] São abordados alguns aspectos relativos à execução de
análises probabilísticas em projetos de geotecnia.
Apresenta-se um resumo dos conceitos de probabilidade e
estatística, utilizados ao longo do trabalho. Descreve-se
uma metodologia para a obtenção dos dados necessários à
análise probabilística, incluindo a quantidade e a
localização de amostras, o cálculo das médias e variâncias
dos parâmetros do solo e a quantificação das incertezas
relativas a estes valores. Apresenta-se o procedimento de
execução dos três métodos probabilísticos mais utilizados
em geotecnia com ênfase especial para o Método do Segundo
Momento de Primeira Ordem. São executadas análises
probabilísticas considerando, separadamente, variações de
altura e inclinação de um talude de mineração sob condições
drenadas. Avalia-se também a aplicação da metodologia de
análise probabilística em situações não-drenadas, através
da análise da estabilidade de um quebra-mar sobre argila
mole. / [en] Some aspects about probabilistic analysis of stability in
geotechnical engineering are studied in this thesis. A
summary about basic concepts of probability and statistics
used along this work is presented. The methodology for
obtaining the data needed for probabilistic analysis is
described, including quantity and localization of samples,
computation of mean and variance of soil properties and
determination of uncertainties about these values. The
procedures of three probabilistic methods which are useful
in geotechnics are presented, with special emphasis on the
first order second moment method (FOSM). Probabilistic
analysis are made considering independent changes of height
and inclination of a mine slope under drained conditions.
The application of probabilistic analysis of a breakwater
above a soft clay deposit under undrained conditions is
also presented. / [es] Se abordan algunos aspectos relativos a la ejecución de
análisis probabilístico en proyectos de geotecnia. Se
presenta un resumen de los conceptos de probabilidades y
estadísticas, utilizados a lo largo del trabajo. Se
describe una metodología para la obtención de los datos
necesarios para el análisis probabilístico, incluyendo la
cantidad y la localización de las muestras, el cálculo de
las medias y variancias de los parámetros del suelo y la
cuantificación de los errores relativos a estos valores. Se
presenta el procedimientode ejecución de los tres métodos
probabilísticos más utilizados en geotecnia con énfasis
especial para el Método del Segundo Momento de Primer
Orden. Se realizan análisis probabilísticos considerando,
separadamente, variaciones de altura e inclinación de un
talud de mineración en condiciones drenadas. También se
evalúa la aplicación de la metodología de análisis
probabilística en situaciones no-drenadas, a través de el
análisis de la estabilidad de un quebra olas sobre arcilla
blanda.
|
52 |
[en] DETERMINISTIC AND PROBABILISTIC ANALYSIS OF SLOPE STABILITY / [pt] ANÁLISE DETERMINÍSTICA E PROBABILÍSTICA DA ESTABILIDADE DE TALUDESMARTIN ALEXANDER PURIZAGA SANDOVAL 31 July 2013 (has links)
[pt] Na abordagem determinística compara-se o método do equilíbrio limite
com o método dos elementos finitos na análise 2D da estabilidade de taludes em
solo, determinando-se o valor do fator de segurança para vários exemplos de
aplicação. No método dos elementos finitos quantifica-se a região da potencial
superfície de ruptura que se comporta sob extensão, analisando-se a ocorrência de
anisotropia de resistência ao longo da potencial superfície de deslizamento para
situações envolvendo diferentes tipos de solo, ângulos de inclinação do talude e
sequências de escavação. Conclui-se que o efeito da anisotropia é pouco
significativo quando o ângulo de atrito do solo exceder a 10 graus. Por outro lado,
devido à crescente aplicação da abordagem probabilística na prática da
engenharia geotécnica, foram realizadas análises de confiabilidade de taludes
empregando os métodos de Monte Carlo, do hipercubo latino e o método das
estimativas pontuais alternativas, comparando-se os diferentes resultados obtidos
e discutindo as principais vantagens da aplicação destes métodos. / [en] In the deterministic approach the limit equilibrium method and the finite
element method are compared for 2D analysis of soil slope stability, calculating
the value of the safety factor in several numerical examples. In the finite element
method the region of soil under strain extension is determined and the occurrence
of strength anisotropy is investigated along the potential sliding surface for
situations involving different types of soil, angles of slope inclination and
excavation sequences. It is concluded that the effect of the anisotropy is negligible
when the angle of friction is higher than 10 degress. Moreover, due to the increasing
application of the probabilistic approach in the practice of geotechnical
engineering, some reliability analyses were carried out using the Monte Carlo
method, the Latin hypercube method and the method of alternative point estimates,
comparing their different outputs and discussing the main advantages of their
application in the analysis of soil slope stability problems.
|
53 |
[en] 2D AND 3D STABILITY OF HIGH SLOPES IN AN OPEN PIT MINE / [pt] ESTABILIDADE 2D E 3D DE TALUDES DE GRANDE ALTURA EM MINA A CÉU ABERTOJORGE GOMEZ SOTO 14 August 2019 (has links)
[pt] Esta dissertação tem como objetivo principal estudar um caso real do comportamento de taludes de grande altura em um projeto de mineração situado no Peru, em termos de deslocamentos e fatores de segurança, considerando uma escavação com uma profundidade que se aproxima de 900 m. As análises tensão x deformação foram executadas pelo método dos elementos finitos, em modelos bi e tridimensionais, considerando o modelo constitutivo de Mohr-Coulomb para os seis diferentes tipos de rocha encontrados na área do projeto. Também foram investigados os efeitos da geometria 3D em análises pseudo-estáticas, tendo em vista a mineração estar situada em região de atividade sísmica, bem como a distância da pilha de material estéril em relação à borda da escavação. De modo geral observou-se que os deslocamentos horizontais e o fator de segurança estático são maiores em analises 3D, enquanto que os deslocamentos verticais resultaram superiores nas análises 2D. Os efeitos da pilha de estéril nos valores do fator de segurança foram pouco significativos, mas a configuração da superfície potencial de ruptura varia de acordo com a distância da pilha à escavação. O fator de segurança pseudo-estático em análises 3D depende da orientação considerada para a força pseudo-estática horizontal. / [en] The main objective of this thesis is to investigate the mechanical behavior of rock slopes of great height in a mining project located in Peru, in terms of displacements and safety factors, considering that the excavation has almost reached the depth of 900m. The stress – strain analyses were carried out by the finite element method considering bi and three-dimensional models and the Mohr-Coulomb constitutive model for the six different types of rock found in the area of the project. The 3D geometrical effects on pseudo-static analyzes were also investigated, since the mine is situated in a region of seismic activity, as well as the influence of the distance of the waste material from the edge of the excavation. In general, it was observed that the horizontal displacements and the static safety factor are larger in 3D analysis while the vertical displacements were superior in 2D models. The effects of the waste dump on the values of the safety factor were insignificant, but the configuration of the potential failure surface varied according to its distance from the excavation. The pseudo-static safety factor in 3D analysis depends on the orientation considered for the horizontal pseudo-static force.
|
54 |
Análise paramétrica da infiltração e sua influência na estabilidade de taludes em solo não saturado / Parametric analysis of infiltration and its influence on unsaturated soil slope stabilitySantos, Cláudio Rodrigues dos 24 March 2004 (has links)
Apresenta-se um estudo paramétrico acerca da infiltração de água e sua repercussão no Fator de Segurança de talude em solos não saturados. Na análise adota-se um talude de referência com geometria fixada conforme a inclinação típica para taludes em areia argilo siltosa, característica do Centro-Oeste do estado de São Paulo. A análise paramétrica foi desenvolvida a partir de uma simulação de fluxo em regime transiente utilizando o programa SEEP/W, que utiliza o método de elementos finitos, e posteriormente uma análise de estabilidade do talude de referência utilizando o método de Bishop simplificado conforme apresentado no programa SLOPE/W. Foram analisados taludes homogêneos compostos por três diferentes tipos de solo, uma areia, um silte argiloso e uma areia argilo siltosa. Os parâmetros analisados compreendem a curva de retenção de água, a função condutividade hidráulica do solo e a intensidade de precipitação. Verificou-se que a função condutividade hidráulica e a pressão de entrada de ar são os principais determinantes do comportamento da infiltração e conseqüentemente da estabilidade do talude. As simulações de fluxo evidenciaram que os taludes em solos mais arenosos apresentam taxas de infiltração maiores que as apresentadas pelos taludes compostos por solos siltosos. Consequentemente, os escorregamentos ocasionados pela perda da contribuição da sucção para a resistência ao cisalhamento ocorrem primeiramente nos taludes compostos por solos arenosos e posteriormente naqueles compostos por solos siltosos, fato este que pôde ser confirmado pelas análises de estabilidade do talude de referência. / A parametric study is presented about water infiltration and its repercussion in the safety factor of unsaturated soil slopes. In the analysis it is adopted a reference slope with determined geometry according to the typical inclination for slopes in silty clayey sand, characteristic of the mid-western region of São Paulo State, in Brazil. The parametric analysis was developed from a flux simulation in transient regime using the SEEP/W software, which uses the finite elements method, and thereafter, a stability analysis of the reference slope using simplified Bishop method, as presented in the SLOPE/W software. Homogeneous slopes composed by three different types of soil (sand, clayey silt and silty clayey sand) were considered. The analyzed parameters include the water retention curve, the hydraulic conductivity function and the precipitation intensity. It was verified that the hydraulic conductivity function and the air entry value are the main determinants of the infiltration behavior and, subsequently, of the slope stability. The flux simulations have evidenced that coarser soils slopes show higher infiltration rates than the ones presented in finer soil slopes. Consequently, the slides caused by the loss of the suction\'s contribution to shear strength occur primarily in coarser soil slopes than in fine soil slopes, what could be verified in the stability analysis of the reference slope.
|
55 |
Análise de ruptura de talude em solo não saturado / Slope back analysis in unsatured soilsCancino Calle, José Antonio 30 June 2000 (has links)
Apresenta-se neste trabalho uma análise de ruptura de um talude em solo não saturado. O talude, com cerca de 15 m de altura, é composto de areia fina a média argilosa, com grau de saturação da ordem de 55% e SPT variando entre 4 golpes no topo a 13 golpes na base. Determinaram-se as seguintes propriedades do solo: resistência, condutividade hidráulica saturada e não saturada e curva de retenção, além de medir-se a sucção matricial em campo ao longo do ano. Efetuaram-se análises paramétricas para avaliar o efeito da precipitação na mudança do perfil de sucção matricial do terreno e suas implicações na resistência e, por extensão, na estabilidade do talude. Construíram-se, também, ábacos que incluem o efeito da variação da sucção matricial, utilizáveis para taludes com características semelhantes ao talude estudado. Verificou-se que para as condições do talude natural, no auge da estação seca, as sucções matriciais são de tal magnitude que fornecem estabilidade ao talude. À medida que ocorrem precipitações, as sucções matriciais reduzem-se e o fator de segurança do talude diminui, o que justifica a ruptura ocorrida. / In this article is showing an slope back analysis in unsaturated soil. The slope, with about 15 m of height, it is composed of a fine to medium clayey sand, with degree of saturation of the order of 55% and SPT varying among 4 blows in the top to 13 blows in the base. The following properties of the soil were determined: resistance, saturated and unsaturated conductivity and it curves of retention, besides measuring the suction along the year. Parametric analyses were made to evaluate the effect of the precipitation in the changes of the ground matricial suction profile and its implications in the resistance and, by extension, in the slope stability. They were also made, some abaci that include the effect of the matricial suction variation, usable for slopes with similar characteristics to the studied slope. It was verified that for the conditions of the natural slope, next to the peak of the dry station, the matricial suction is of such magnitude that it supply stability to the slope. In the successive events of precipitations the matricials suctions is reduced and the slope security factor decreases, that justifies the happened rupture.
|
56 |
Mapeamento geotécnico dos principais condicionantes de ruptura de taludes de corte da duplicação da BR-116 entre São Lourenço do Sul e Barra do Ribeiro (RS) / Mapping the geotechnical controlling factors for sliding road cuts during the BR-116 duplication beyween São Lourenço do Sul and Barra do Ribeiro (RS)Ziebell, Arthur January 2017 (has links)
A BR 116, no Rio Grande do Sul, perfaz uma extensão total de 653,8 quilômetros, iniciando na divisa entre SC e RS, na ponte sobre o Rio Pelotas, entre Lajes e Vacaria, prolongando-se até Jaguarão. A sua importância econômica no estado decorre do fato de ser um corredor que liga o norte do Rio Grande do Sul ao porto de Rio Grande (através da BR 392) e à fronteira com o Uruguai. A duplicação da BR-116 visa o escoamento da produção até o Porto de Rio Grande e a distribuição de produtos e bens que ingressam pelo Porto ou pela fronteira. Atualmente, as obras de duplicação encontram-se executadas em 50-60 % e parcialmente paralisadas (cada trecho/lote tem uma situação diferente). Este trabalho dedicou-se ao mapeamento geotécnico dos condicionantes de ruptura dos taludes de cortes rodoviários da BR-116, entre os municípios de São Lourenço do Sul e Barra do Ribeiro (RS). A investigação ocorreu por meio da análise dos taludes em campo, estudando as relações geológicas e pedológicas que condicionam as instabilidades situadas ao longo do trecho entre os quilômetros 332 e 477. O mapeamento geotécnico executado incluiu o levantamento da localização geográfica (coordenadas geográficas, e km da rodovia) de todos os cortes de estrada (taludes) existentes no trecho escolhido, bem como o levantamento fotográfico e a coleta de dados como altura, inclinação, extensão, cota altimétrica, medidas estruturais, medidas e descrição dos horizontes pedogenéticos, problemas geotécnicos, comportamento mecânico, fluxo de água superficial, nível do lençol freático, descrição geológica, descrição do nível de intemperismo e coleta de amostra para ensaios geotécnicos e difratometria de raios X Após as descrições de campo, os talude 8, 15 e 30 foram definidos como taludes representativos para análise mineralógica através de difração de raios X e caracterização dos argilo-minerais através de microscópio eletrônico de varredura. O talude 8 ainda contou com ensaios de cisalhamento direto para caracterização geomecânica do horizonte C. Esta análise permitiu definir que o principal condicionante para as rupturas de taludes na BR-116, trecho Sul, está na exposição do horizonte C, que induz diferentes tipos de processos erosivos sobre o mesmo. As investigações mostraram que a exposição do horizonte C faz com que a água da chuva aja na erosão direta do sopé do talude, ou na formação de canaletas e piping pela remoção de finos, os quais evoluem para bossorocas. As estruturas geológicas reliquiares preenchidas por caulinita também incrementam os processos erosivos, pela retirada da base estrutural de todo o corte. Assim, os horizontes A e B e a vegetação logo acima perdem sustentação e a gravidade determina o rompimento do talude em escorregamentos rotacionais. A continuidade dos eventos pluviométricos e, portanto, dos processos erosivos induzem novas rupturas em alguns taludes, ou na erosão direta do material escorregado para a base do talude, removendo material para as drenagens adjacentes. / The BR-116 is one of the most important longitudinal highways in Rio Grande do Sul state (RS, Brazil). The highway has 653.8 kilometers, starting at the bridge over the Pelotas River, and extending to Jaguarão city. It is part of an important economic corridor, that connects the north of RS to the Rio Grande Harbor (through BR 392) and Uruguay border. Therefore, the importance of the highway to the economic outflow from the state. The BR-116 duplication effort is actually halfway to the end, each segment in a different situation, and is slowly going on. This work was focused on mapping the geotechnical controlling factor for road cuts slidings, that occurred between São Lourenço do Sul and Barra do Ribeiro municipalities (RS) along BR-116 highway. The geotechnical investigation was carried out through fieldworks road cut slopes analysis, which included geology and pedology slopes characterization along the 332 and 477 kilometer of the BR-116 highway. The geotechnical field mapping procedures include recording and analyzing the geographic location (geodetic coordinates, and altimeter), photographic survey, and mainly the height, inclination, extension, structural features measurements, measure and description of pedogenetic horizons, geotechnical problems, mechanical behavior, surface water flow, groundwater level, geological description, description of weathering level and sample collection for all road cut slopes that show sliding or erosional features. The slopes numbered 8, 15 and 30 were defined as representative slopes for mineralogical analysis (X-ray diffraction and scanning electronic microscope) This analyses allowed to define that the main controlling factor for the road cut sliding along BR-116 under duplication is the exposure of the pedogenetic C horizon, since this enables different erosional processes upon it. The investigation has shown that the rainwater can acts directly on the footwall erosion, or even in the formation of channels and piping, which evolve to ravines. The relict geological structures weathered to kaolinite additionally contribute to the erosion processes. In such a scenario, the decreasing structural support due to C horizon erosion enable gravity to act upon pedogenetic A and B horizons, as well as on the vegetation cover just above, and cause rotational sliping on the road cut slopes. The subsequent pluviometric events contribute to additional direct erosion on slope footwall, to material removal to adjacent drainage channels, and, consequently, to repeated sliping in some slopes.
|
57 |
Infuência do perfil de sucção no dimensionamento de solo grampeado em solo não saturadoSilva , Emilly Dias da 29 January 2016 (has links)
Submitted by Luciana Ferreira (lucgeral@gmail.com) on 2017-01-26T09:23:06Z
No. of bitstreams: 2
Dissertação - Emilly Dias da Silva - 2016.pdf: 6131512 bytes, checksum: 2ebac9ad8e2116f4ee2c3159379816ca (MD5)
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2017-01-26T09:23:41Z (GMT) No. of bitstreams: 2
Dissertação - Emilly Dias da Silva - 2016.pdf: 6131512 bytes, checksum: 2ebac9ad8e2116f4ee2c3159379816ca (MD5)
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2017-01-26T09:23:41Z (GMT). No. of bitstreams: 2
Dissertação - Emilly Dias da Silva - 2016.pdf: 6131512 bytes, checksum: 2ebac9ad8e2116f4ee2c3159379816ca (MD5)
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Previous issue date: 2016-01-29 / The use of soil nailing technique can be an important alternative for the stabilization of a slope or an excavation. Nails are retaining elements that reinforce soil masses acting passively, requiring strains to mobilize their resistance. The mechanical behavior analysis of a structure with soil nailing technique can be made using limit equilibrium methods, being represented by loads applied to reinforcing layers or sub-horizontal slices of a slope. The slice has its base crossed by a reinforcing action line and the reinforcing nail is treated as a concentrated point load acting on the base point of intersection of a slice with the line of action. Thus, through analytical and numerical calculations, this dissertation studied the design of soil nailing structure considering variations of suction, which influences the soil resistance, simulating suction profiles of a typical soil of the Brazilian Midwest region. This study was conducted determining strength parameters on nail-soil interface by tests in the field, i.e. nail pullout tests, and soil strength and hydromechanical parameters determined in the laboratory. For this, two separate suction sections were studied, and in each case, numerically analyzed in soil nailing structures, obtaining the dimensions of the structure through a pre-sizing phase, and then analyzing the factor of safety of the structure using computer programming considering the Bishop method. In the first case, the distribution of suction was numerically simulated for the soil profile studied in a critical condition of rainfall in Goiania region. Then, the suction field profile was obtained for comparison with the first case. With the results of this research, it was possible to understand the increasement of resistance and safety fator of the structure when considering the suction effects at the design of soil nailed structures in a typical soil of Goiânia region. / A utilização de contenções em solo grampeado pode ser uma importante alternativa para a estabilização de um talude ou de uma escavação. Os grampos ou tirantes passivos são elementos de contenção ou de reforço de massas de solo que agem passivamente, requerendo deformações para mobilizar sua resistência. A análise do comportamento mecânico de uma estrutura onde existe solo grampeado pode ser feita através de métodos de equilíbrio limite, sendo representada por cargas de reforço aplicadas a camadas ou fatias sub-horizontais de um talude. A fatia tem a sua base atravessada por uma linha de ação de reforço e a carga de reforço é tratada como uma carga
pontual concentrada agindo no ponto de intersecção da base de uma fatia com a linha de ação. Assim, através de cálculos por ferramentas analíticas e numéricas, o presente trabalho estudou o dimensionamento da estrutura de solo grampeado considerando a variação de sucção, que influencia a resistência do solo, simulando perfis de sucção de um solo típico da região do centro oeste brasileiro. Esse estudo foi realizado determinando parâmetros de resistência na interface grampo-solo por ensaios realizados em campo, como ensaios de arrancamento de grampo, e parâmetros de resistência e hidromecânicos do solo não saturado determinados em laboratório. Para isso, foram estudados dois perfis de sucção distintos e, para cada caso, analisou-se numericamente a estrutura de contenção em solo grampeado, obtendo-se as dimensões da estrutura através de um pré-dimensionamento, e, a seguir, analisando o fator de segurança da contenção utilizando programação computacional considerando o método de Bishop. No primeiro caso foi simulada numericamente a distribuição do perfil de sucção do solo estudado para uma condição de precipitação crítica na região de Goiânia. No segundo, foi obtido o perfil de sucção de campo para comparação com o primeiro caso. Com os resultados desta pesquisa, foi possível compreender o aumento da resistência e do fator de segurança da contenção ao considerar os efeitos de sucção no dimensionamento de uma estrutura de contenção em solo grampeado típico da região de Goiânia.
|
58 |
Avaliação de mecanismos não convencionais de instabilização de encostas: o papel das poropressões de ar / Evaluation of unconventional mechanisms of slope instabilization: the role of pore-air pressureTerra, Victor Scartezini 29 August 2016 (has links)
Submitted by Cássia Santos (cassia.bcufg@gmail.com) on 2017-01-30T10:00:16Z
No. of bitstreams: 2
Dissertação - Victor Scartezini Terra - 2016.pdf: 3940729 bytes, checksum: 27241c105d696ce18e125b5eb6c44691 (MD5)
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2017-01-30T10:04:56Z (GMT) No. of bitstreams: 2
Dissertação - Victor Scartezini Terra - 2016.pdf: 3940729 bytes, checksum: 27241c105d696ce18e125b5eb6c44691 (MD5)
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2017-01-30T10:04:56Z (GMT). No. of bitstreams: 2
Dissertação - Victor Scartezini Terra - 2016.pdf: 3940729 bytes, checksum: 27241c105d696ce18e125b5eb6c44691 (MD5)
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Previous issue date: 2016-08-29 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / Natural disasters related to landslides have caused thousands of deaths and left tens of thousands
homeless people around the world. Landslides can occur in most cases due to factors related to
water infiltration on soil, causing a raise in the positive pore-water pressure. But what is often
observed is that both water infiltration and the reduction of negative pore-water pressure due to
water infiltration are not, in practice, enough to justify some of the observed landslides. Some less
conventionals mechanisms, such as lightning, are not, usually, taken in consideration in a failure
analysis, but can contribute to the factor of safety reduction. This paper aims to study the effects of
atmospheric discharges in the stability of natural slopes of residual soils. Partial differential
equations governing the coupled flow of pore-water and pore-air are developped. The numerical
modeling is made with the FlexPDE software, version 6. The results show that there is a raise on
pore-air pressure inside the soil due to atmospheric discharge. However, the raise of pore-air
pressure works both in the raise of the apparent cohesion and the reduction on net pressure. It is
concluded that any failure due to atmospheric discharge will present a shallow slip surface. / Desastres naturais relacionados a deslizamentos de massas de terra já causaram milhares de mortes e dezenas de milhares de desabrigados no mundo inteiro. Os deslizamentos podem ocorrer em sua maioria devido aos fatores provenientes da infiltração de água no solo, gerando aumento das poropressões positivas de água. Mas o que se observa frequentemente, é que a infiltração e a redução das poropressões negativas muitas vezes não são, na prática, o suficiente para justificar todos os escorregamentos observados. Mecanismos menos convencionais como descargas atmosféricas e o aumento das poropressões de ar consequentes do efeito Lisse normalmente não
são levados em consideração em análises de ruptura, mas podem contribuir para a diminuição do
fator de segurança de taludes. Esta pesquisa tem como objetivos, portanto, estudar como os efeitos
do avanço da frente de infiltração e das descargas atmosféricas irão afetar a estabilidade de taludes
em encostas naturais de solos residuais. Além disso, cita-se como objetivos secundários o
desenvolvimento de modelos numéricos para análises acopladas de fluxo de água e ar, e a
verificação desses modelos por meio de análises de validação. Um estudo detalhado de como a
onda de choque e os gradientes de temperatura de descargas atmosféricas se comportam ao atingir
a superfície terrestre é desenvolvido para que se possam definir as condições de fronteira do
problema. Equações diferenciais parciais acopladas para fluxo de água e ar são desenvolvidas. As
análises são feitas com o auxílio do programa FlexPDE, versão 6. Os resultados mostraram que há
um aumento das poropressões de ar na massa de solo provenientes de descargas atmosféricas ou do
efeito Lisse. No entanto, tais acréscimos de poropressão de ar trabalham tanto a favor do ganho de
coesão aparente como como na diminuição das tensões líquidas. No estudo da influência do
aumento das poropressões de ar como consequência de descargas atmosféricas conclui-se que
eventuais rupturas de taludes causadas por isso serão rasas. Com relação ao estudo do aumento de
poropressão de ar em taludes como consequência do efeito Lisse, conclui-se que os acréscimos de
poropressão de ar serão maiores na massa de solo quando mais próximo da saturação estiver o
solo.
|
59 |
Estudo geotécnico de dois taludes da formação serra geral, RSPerazzolo, Lilian January 2003 (has links)
Esta dissertação de mestrado apresenta um estudo sobre dois taludes coluvionares localizados na região nordeste do Rio Grande do Sul, inseridos no contexto geológico da Formação Serra Geral. Estes taludes apresentam características e comportamento geotécnico distintos. O objetivo desta dissertação é obter parâmetros de condutividade hidráulica e resistência ao cisalhamento dos solos presentes nos dois taludes, a fim de entender os diferentes processos de ruptura observados. Um dos taludes, denominado talude de Canastra, apresenta um processo de rastejo; este talude tem uma inclinação bastante suave e apresenta uma camada de colúvio sobre um solo residual de basalto vesicular. O talude de Canastra apresenta uma camada de transição entre o colúvio e o solo residual; os ensaios de condutividade hidráulica realizados em campo mostraram que esta camada é menos permeável do que o colúvio e o solo residual, formando uma camada quase impermeável e criando condições para a formação de dois níveis freáticos neste talude. Nos solos deste talude foi detectada a presença significante de argila expansiva (montmorilonita). O outro talude estudado, denominado de talude da rodovia RS470, apresentou uma ruptura abrupta após um período de intensa chuva. Este talude apresenta uma inclinação bastante íngreme e um solo coluvionar assente diretamente sobre basalto alterado. A condutividade hidráulica deste colúvio é bastante elevada. O colúvio apresenta pouca argila expansiva, sendo formado essencialmente por caulinita. Os ensaios ring shear, realizados para a obtenção de parâmetros de resistência ao cisalhamento residual nos solos dos dois taludes, apresentaram valores muito baixos de φr, inferiores a 10° Valores semelhantes foram encontrados por Pinheiro (2000) e Rigo (2000) em solos residuais de basalto da Formação Serra Geral. Foram realizadas simulações numéricas de fluxo d’água e de estabilidade destes taludes, na tentativa de verificar as condições em que aconteceram os escorregamentos.
|
60 |
Comportamento geotécnico de um solo coluvionar de São Vendelino (RS) / Geotechnical behavior of a colluvium soil from São Vendelino (RS, Brazil)Silveira, Rodrigo Moraes da January 2008 (has links)
Nesta tese foram executados diversos ensaios geotécnicos em um solo coluvionar de uma encosta em que ocorreu uma ruptura translacional, seguida de liquefação e corrida de detritos, em São Vendelino (RS). Na mesma área ocorreram dezenas de rupturas de taludes em dezembro de 2000, durante um evento pluviométrico com chuvas de 148 mm medidas em 2 h. Os taludes da região apresentam declividades em torno de 27-36° com uma camada superficial de solo coluvionar (aproximadamente 2 m). Os solos amostrados foram retirados junto da cicatriz de um destes movimentos, o qual uma testemunha ocular descreveu como uma ruptura de grande mobilidade e fluidez. No trabalho é apresentada (a) uma caracterização geral das propriedades geotécnicas dos solos coluvionares da área de estudo, a partir de um conjunto de ensaios realizados em amostras deformadas e indeformadas coletadas em campo; (b) resultados do monitoramento de poro-pressões por piezômetros elétricos e um pluviômetro, instalados na encosta; (c) ensaios de condutividade hidráulica de laboratório e de campo (permeâmetro de Guelph, piezômetros de Casagrande e cilindros concêntricos); (d) um conjunto de resultados de ensaios de cisalhamento direto, ensaios de compressão triaxial CID, CIU, CID-U e CSD (constant shear drained) e (e) um conjunto de ensaios hollow cylinder. Os ensaios de condutividade hidráulica realizados em laboratório com amostras indeformadas forneceram valores entre 2,5x10-4 e 5,4x10-3 cm/s. Os resultados dos ensaios de cisalhamento resultaram em valores c =4-10 kPa e f = 26º (remoldados ou indeformados) e c =0-10 kPa e f =25,8-36,9º (triaxiais em solo remoldado). Os ensaios hollow cylinder realizados mostraram que há uma grande influência da rotação das tensões principais nos parâmetros de resistência ao cisalhamento e no comportamento do solo pré e pós-ruptura. Os resultados também sugerem que análises de estabilidade de taludes baseadas nos parâmetros de resistência ao cisalhamento obtidos a partir de ensaios de compressão triaxial não são conservativas. Análises de fluxo de água e de estabilidade da encosta sugerem que somente chuvas com intensidade de magnitude semelhante à de dezembro de 2000 podem provocar rupturas na encosta estudada. / In this thesis several geotechnical tests were performed in a colluvium soil from a slope in which a translational slide occurred, followed by liquefaction and debris flow, in São Vendelino, RS, Brazil. In the same area several other slope failures occurred in December 2000 during a rain event with precipitation of 148mm in 2 hours. The inclination of the slopes in the region are in the range of 27-36o with a surficial layer of colluvium soil (approximately 2 m). The soil samples soil were collected close to a scar generated by one of those movements, which an eye-witness described as a failure with great mobility. This thesis presents (a) a basic characterization of colluvium soils from the studied area, using disturbed and undisturbed samples; (b) monitored values of in-situ pore-pressure using electric piezometers and results of a pluviometer installed in the studied area; (c) results of hydraulic conductivity from laboratory and field tests (Guelph permeameter, Casagrande piezometers and concentric cylinders); (d) results from direct shear and triaxial tests (CID, CIU, CID-U and CSD) and (e) a set of hollow cylinder tests. The laboratory conductivity hydraulic tests carried out on undisturbed samples showed values variyng from 2.5x10-4 to 5.4x10-3 cm/s. The direct shear results resulted in c =4-10 kPa e f =26º (undisturbed or reconstituted samples) and triaxial tests resulted in c =0-10 kPa and f =25.8-36.9º (reconstituted samples). The hollow cylinder tests showed that there is a strong influence of principal stress rotation in the shear strength and in the soil behavior pre and post failure. The results also suggest that slope stability analyses based on shear strength parameters obtained from triaxial tests are not conservative. Seepage and slope stability analyses suggest that only rains of great intensity, similar to the event of December 2000, may generate failures in the studied slope.
|
Page generated in 0.1098 seconds