• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 77
  • 3
  • Tagged with
  • 83
  • 83
  • 67
  • 59
  • 57
  • 45
  • 41
  • 39
  • 35
  • 25
  • 18
  • 18
  • 17
  • 16
  • 16
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Metodologia para depuração off-line de parâmetros série e shunt de linhas de transmissão através de diversas amostras de medidas / Methodology for off-line validation of transmission line parameters via several measurement snapshots

Albertini, Madeleine Rocio Medrano Castillo 08 September 2010 (has links)
Neste trabalho propõe-se uma metodologia off-line, prática e eficiente, para detectar, identificar e corrigir erros em parâmetros série e shunt de linhas de transmissão. As linhas de transmissão, ou ramos do modelo barra-ramo, suspeitas de estarem com EPs são identificadas através do Índice de Suspeita (IS). O IS de um ramo é a relação entre o número de medidas incidentes a esse ramo, cujos resíduos normalizados são maiores que um valor pré-estabelecido, e o número total de medidas incidentes a esse ramo. Usando várias amostras de medidas, os parâmetros dos ramos suspeitos são estimados, de forma seqüencial, via um estimador de estado e parâmetros baseado nas equações normais, que aumenta o vetor de variáveis de estado para inclusão dos parâmetros suspeitos. Resultados numéricos de diversas simulações, com os sistemas de 14, 30 e 57 barras do IEEE, têm demonstrado a alta precisão e confiabilidade da metodologia proposta, mesmo na ocorrência de erros múltiplos (em mais de um parâmetro) em ramos adjacentes, como também em linhas de transmissão paralelas com compensação série. Comprovou-se a viabilidade prática da metodologia proposta através da aplicação da mesma, para depuração (detecção, identificação e correção) dos valores dos parâmetros de dois subsistemas da Hydro-Québec Trans-Énergie. / A practical and efficient off-line approach to detect, identify and correct series and shunt branch parameter errors is proposed in this thesis. The branches suspected of having parameter errors are identified by means of the Suspicious Index (SI). The SI of a branch is the ratio between the number of measurements incident to that branch, whose normalized residuals are larger than one specified threshold value, and the total number of measurements incident to that branch. Using several measurement snapshots, the suspicious parameters are sequentially estimated, via an augmented state and parameter estimator which increases the V-\'teta\' state vector for the inclusion of suspicious parameters. Several simulation results (with IEEE 14, 30 and 57 bus systems) have demonstrated the high accuracy and reliability of the proposed approach to de al with single and multiple parameter errors in adjacent and non-adjacent branches, as well as in parallel transmission lines with series compensation. The proposed approach is confirmed by tests performed in two subsystems of the Hydro-Québec Trans-Énergie.
42

Fontes distribuídas de harmônicos em sistemas elétricos de potência. / Distributed harmonic sources in electric power systems.

Almeida, Carlos Frederico Meschini 13 December 2011 (has links)
A tendência crescente na geração de harmônicos nos sistemas elétricos de potência tem ganhado atenção especial no planejamento das redes de transporte de energia elétrica, uma vez que os crescimentos observados acontecem em regiões que antes não representavam qualquer tipo de preocupação. Um dos principais fatores que contribuíram para esse novo contexto é a característica distribuída da geração de harmônicos. Devido a essa nova realidade, métodos mais aprimorados para avaliação de desempenho e modelos mais precisos para a representação de equipamentos tornaram-se necessários. Sendo assim, a pesquisa realizada para a elaboração da presente tese fundamentou a sua investigação em três tópicos com o intuído de fornecer contribuições que permitissem uma avaliação mais precisa das redes elétricas, proporcionando, assim, resultados mais aderentes com a realidade existente: Modelagem Agregada de Carga; Equivalentes de Redes; Estimação de Estados das Distorções Harmônicas. Através das contribuições feitas nesses tópicos, torna-se possível a consideração de aspectos que antes eram ignorados na avaliação harmônica das redes de transporte de energia elétrica e, assim, permite-se uma verificação precisa dos impactos da característica distribuída da geração de harmônicos nos sistemas elétricos de potência. / The growing rate of harmonic generation present in the electric power systems has gained special attention in the planning process of power networks. The major factor that contributed for this new context is the increasing harmonic generation observed in regions that did not use to represent any concern in the past. One of the main causes for this new trend is the distributed characteristic of the harmonic generation. In this new environment, sophisticated methods and models have become necessary, in order to precisely represent the electric elements behaviour and to accurately evaluate the systems performance. As a result, the research work presented in this thesis focused in three different topics, in order to provide contributions that would lead to a more accurate performance evaluation of the power networks and that would provide results closer to the values found in the field: Aggregate Load Modeling; Network Equivalents; Harmonic State Estimation. These contributions would allow the consideration of aspects that normally are ignored in the harmonic assessment of power systems. Consequently, the evaluation of the impacts caused by the distributed generation of harmonics becomes more accurate.
43

Estimação de estado em sistemas elétricos de potência: composição de erros de medidas / State estimation in power systems: measurement error composition

Piereti, Saulo Augusto Ribeiro 10 August 2011 (has links)
Bretas et al. (2009) prova matematicamente, e através da interpretação geométrica, que o erro de medida se divide em componentes detectáveis e não-detectáveis. Demonstra ainda que as metodologias até então utilizadas, para o processamento de Erros Grosseiros (EGs), consideram apenas a componente detectável do erro. Assim, dependendo da amplitude das componentes do erro, essas metodologias podem falhar. Face ao exposto, neste trabalho é proposto uma nova metodologia para processar as medidas portadoras de EGs. Essa proposição será obtida decompondo o erro da medida em duas componentes: a primeira, é ortogonal ao espaço da imagem da matriz jacobiana cuja amplitude é igual ao resíduo da medida, a outra, pertence ao espaço da imagem da matriz jacobiana e que, por conseguinte, não contribui para o resíduo da medida. A relação entre a norma dessas componentes, aqui denominado Índice de Inovação (II), prevê uma nova informação, isto é, informação não contida nas outras medidas. Usando o II, calcula-se um valor limiar (TV) para cada medida, esse limiar será utilizado para inferir se a medida é ou não suspeita de possuir EG. Em seguida, com as medidas suspeitas em mãos, desenvolve-se um índice de filtragem (FI) que será utilizado para identificar qual daquelas medidas tem maior probabilidade de possuir EG. Os sistemas de 14 e 30 barras do IEEE, e o sistema sul reduzido do Brasil de 45 barras, serão utilizados para mostrar a eficiência da metodologia proposta. Os testes realizados com os sistemas acima são: i) O teste de nível de detecção de EG, que consisti em encontrar o valor mínimo de EG que seja detectado usando o TV da medida; ii) O teste onde é adicionado EG de 10 desvios padrões em cada medida, uma por vez, nesse teste o FI da medida é usado para identificar qual medida possui o erro, em seguida à medida com erro é corrigida através do erro normalizado composto (ENC); iii) O teste de EG simples. / Bretas et al. (2009) has proved, using geometric background, that the measurement error can be decomposed into two components the detectable and the undetectable component respectively. Bretas has also demonstrated that the current methodologies used for processing of gross errors (GE), consider only the detectable component of the error. Thus, depending on the magnitude of the undetectable error components, such methods may fail. Given the above explanation, in this work a new methodology for processing the measurements with GE is proposed. This proposition is obtained by decomposing each measurement error into two components: the first, orthogonal to the Jacobian range space, whose magnitude is equal to the measurement residual and the other contained in that space, which does not contribute to the measurement residual. The ratio between the norms of those components was proposed as the measurement Innovation Index (II) which provides the new information a measurement contains regarding the other measurements. Using the II, a threshold value (TV) for each measurement is computed so that one can declare a measurement suspicious of having a GE. Then a filtering index (FI) is proposed to filter up, from the suspicious measurements, the one that has more chances of containing a GE. The IEEE-14 bus system, IEEE-30 bus system, and reduced 45-bus power system of south of Brazil, will be used to demonstrate the accuracy and efficiency of the proposed methodology. Tests conducted with the above systems were: i) The level test for GE detection, which consists in finding the minimum GE value in order it can be detected using the measurement TV; ii) The test where GE of 10 standard deviations is added to each measurement, once at a time, and using the measurement FI to identify which measurement has the error ant the using the composed measurement error (CNE) to correct measurement value; iii) The GE simple test.
44

Análise de observabilidade e de redundância de medidas no contexto de estimação de estado trifásica / Observability and measurement redundancy analysis on three-phase state estimation

Fantin, Camila dos Anjos 27 February 2012 (has links)
Este trabalho de dissertação trata do problema de observabilidade e redundância de medidas para efeito de estimação de estado trifásica. É proposta a extensão de uma metodologia numérica eficiente para análise de observabilidade e identificação de medidas críticas e conjuntos críticos de medidas, desenvolvida para modelagem por fase, a fim de considerar redes trifásicas de energia, nas quais os desbalanços nas cargas e os desequilíbrios na rede são considerados. Ao longo do trabalho apresenta-se uma revisão dos principais conceitos de estimação de estado, observabilidade de redes e redundância de medidas, destacando a importância da estimação de estado trifásica para obtenção de uma operação segura de sistemas elétricos de potência desbalanceados e/ou desequilibrados. Os resultados obtidos em diversos testes realizados, com sistemas trifásicos já empregados em outros trabalhos da área contendo 4, 7 e 38 barras, atestam o adequado desempenho da extensão proposta e são apresentados detalhadamente nesta dissertação. Por fim, o conceito de observabilidade topológica, desenvolvido para modelagem monofásica da rede, é estendido para modelagem trifásica, permitindo um entendimento melhor do problema de observabilidade no contexto de estimação trifásica. / This thesis focuses on the problem of observability and measurement redundancy in the context of three-phase state estimation. It is proposed an extension of an efficient numerical methodology for observability and redundancy analysis, developed for the single-phase network model, in order to consider the three-phase network model, where the unbalanced loads and the asymmetric nature of the system are considered. During this work, a review of the main concepts related to state estimation, network observability and measurement redundancy are presented, highlighting the importance of the three-phase state estimation in order to obtain a reliable operation of unbalanced and/or asymmetric power systems. Simulations results obtained for several cases studies based on three three-phase systems already used in the literature, with 4, 7 and 38 buses, validate the proposed methodology extension and are presented in detail in this thesis. Finally, the concept of topological observability, developed for the single-phase network model, is extended for the three-phase model.
45

Estimação de demanda em tempo real para sistemas de distribuição radiais / Real time load estimation for radial distribution systems

Massignan, Julio Augusto Druzina 01 August 2016 (has links)
Para implantação de diversas funções de controle e operação em tempo real em Sistemas de Distribuição (SDs), como, por exemplo, restabelecimento de energia, é necessário um procedimento para representar a carga em tempo real. Ou seja, uma metodologia que possibilite a estimação em tempo real das demandas dos transformadores de distribuição que em geral não são monitoradas de forma direta. Para esse fim propõe-se, neste trabalho, um Estimador de Demanda em Tempo Real (EDTR) baseado em: informações off-line (consumo mensal dos consumidores e curvas de carga típicas); um algoritmo computacionalmente eficiente para cálculo de fluxo de potência baseado na estrutura de dados denominada Representação Nó-Profundidade (RNP); e nas poucas medidas disponíveis em tempo real nos SDs. O EDTR proposto opera em dois estágios: (1) Estimação Off-line das Demandas; e (2) Refinamento em Tempo Real das Demandas, executados em instantes diferentes (um de maneira off-line e outro em tempo real), de forma a prover uma estimativa das demandas dos transformadores de distribuição. Considerando somente as informações off-line, o EDTR proposto permite a estimação das demandas dos transformadores de distribuição com uma medida da incerteza da estimativa. Através do processamento das medidas disponíveis em tempo real, via um algoritmo eficiente para cálculo de fluxo de potência, o EDTR proposto permite o refinamento das estimativas off-line. Neste trabalho serão apresentados resultados de diversas simulações computacionais demonstrando a eficiência do EDTR proposto. Alguns parâmetros são avaliados quanto à influência nas estimativas do EDTR proposto, como a presença de erros grosseiros nas medidas disponíveis em tempo real e alimentadores somente com medidas de magnitude de corrente. Além disto, destaca-se a influência da qualidade das estimativas iniciais obtidas pelo Estágio (1), e a importância das hipóteses estatísticas utilizadas nesse estágio para o processo de estimação. Apresenta-se, ainda, a aplicação do EDTR proposto em um SD real brasileiro. Um teste de validação foi realizado através de uma campanha de medição em um alimentador real, que consistiu na instalação de medidores de demanda em três transformadores de distribuição para aferir a qualidade das estimativas obtidas pelo EDTR proposto. Finalmente, o EDTR proposto é aplicado em um SD real de larga escala, para aferir o desempenho computacional da metodologia implantada e as dificuldades de implantação. Vale ressaltar que sua implantação é condizente com ferramentas consolidadas nos Centros de Operação da Distribuição, como o uso do processo de agregação de cargas e o cálculo de fluxo de potência, e poucas rotinas precisam ser adicionadas para integração do EDTR. / Several real time control and operation applications for Distribution Systems (DS), such as, service restoration, require a procedure for real time load modeling. That is, a methodology for real time estimation of the distribution transformers loading which are generally not monitored. For this purpose, in this dissertation, a Real Time Load Estimator (RTLE) is proposed based on: off-line information (monthly consumption and typical load curves); a computationally efficient algorithm for power flow calculation based on the data structure called Node-Depth Encoding; and on the few available real time measurements on the distribution system. The proposed RTLE operates in two stages: (1) Off-line Load Estimation and (2) Real Time Load Refinement, performed in different moments (one off-line and the other in real time), providing the distribution transformers load estimates. Using only the offline information, the proposed RTLE allows the estimation of the loads of the distribution transformers with a measure of uncertainty. By processing the available real time measurements, using an efficient power flow calculation algorithm, the proposed RTLE refines these off-line estimates. This dissertation presents several simulations showing the efficiency of the proposed RTLE. Some parameters are evaluated and their influence on the RTLE load estimates, such as gross errors in the available real time measurements and feeders with only current magnitude measurements. Besides, it is emphasized the influence of the initial load estimates obtained from Stage (1), and the importance of the statistical hypothesis used in this stage in the load estimation process. Also, this work presents the application of the proposed RTLE in a real Brazilian DS. A validation test was performed through in-field verification in a real distribution feeder, which was executed via load meters installation in three distribution transformers to evaluate the quality of the load estimates provided by the RTLE. Finally, the proposed RTLE was tested in a real large scale DS to evaluate its computational performance and the difficult level of its implementation. It is noteworthy that its implementation is straightforward with other Distribution Operation Center tools, such as load aggregation and load flow calculation, and few routines must be added for integrating the RTLE.
46

VG2E: ferramenta computacional para visualização gráfica / VG2E: computational tool for visualization graphics

Salgado, José Carlos Menezes 26 February 2010 (has links)
Propõem-se desenvolver uma ferramenta computacional voltado a objeto que permita a visualização gráfica, de forma amigável, dos resultados da dissertação de mestrado: Sistema de avaliação da qualidade e redundância das medidas para estimação de estados em sistemas elétricos de potência. A ferramenta foi desenvolvida na plataforma Windows utilizando o Microsoft C Sharp no ambiente DotNet. Os testes foram executados em resultados em redes de 14 barras. Este trabalho foi o passo inicial para elaborar uma melhor integração das diferentes dissertações num ambiente computacional moderno, cuja visualização dos resultados seja de forma mais didática e objetiva. / This paper objects develop a user friendly, object oriented, graphic computational, tool, using the output results of the paper: Sistema de avaliação da qualidade e redundância das medidas para estimação de estados em sistemas elétricos de potência. The tool was developed on Windows platform, using Microsoft C Sharp in DotNet environment. The tests were performed using numbers of networks of 14 bars. This work was the first step to develop a better integration of dissertations in a modern computing environment, which is the viewing DSO results in a more intuitive and objective.
47

Análise de observabilidade e identificação de medidas críticas para sistemas de medição formados por medidas convencionais e fasoriais sincronizadas / Observability analysis and identification of critical measurements for metering systems formed by conventional and synchronized phasor measurements

Borges, Guilherme Pereira 04 May 2011 (has links)
Neste trabalho de dissertação propõe-se uma metodologia para análise de observabilidade (restauração e identificação de ilhas) e identificação de medidas críticas para sistemas de medição formados por medidas convencionais (medidas de amplitude de tensão e de potência obtidas via sistema SCADA) e medidas fasoriais sincronizadas. A metodologia possibilita análise e restauração da observabilidade a partir da fatoração triangular da matriz jacobiana, associada a um sistema de medição possuindo medidas convencionais e fasoriais sincronizadas. Para identificar as ilhas observáveis, no caso de o sistema não ser observável como um todo, a metodologia faz uso do conceito de caminhos de fatoração, associado à matriz jacobiana fatorada. As medidas críticas são identificadas a partir da análise da estrutura da matriz H \'delta\' t, que é obtida a partir da fatoração triangular da matriz jacobiana. A metodologia proposta é simples, de execução rápida, de fácil implantação e não exige a solução de equações algébricas. Dessa forma a mesma atende aos requisitos para operação em tempo-real. Com o intuito de mostrar como a metodologia proposta funciona, são apresentados exemplos da sua aplicação em um sistema teste de 4 barras. Vale destacar que resultados de diversas simulações computacionais, utilizando os sistemas teste do IEEE (14, 30 e 57 barras), têm demonstrado a eficiência da metodologia. / This dissertation proposes a methodology for observability analysis (restoration and identification of observable islands) and identification of critical measurements for metering systems composed of both synchronized phasor and conventional measurements (power and voltage magnitude measurements). The methodology enables observability analysis and restoration via the triangular factorization of the jacobian matrix associated with metering systems formed by those two types of measurements. The identification of observable islands is carried out through the analysis of the path graphs associated with the factorization of the jacobian matrix. Critical measurements are identified via analysis of the structure of the H \'delta\' t matrix, which is obtained by the triangular factorization of the jacobian matrix. The methodology is simple, fast and easy to implement and does not require solutions of any algebraic equation. Consequently, it is useful for real-time operation. Small numerical examples, using a 4-bus test system, showing the application of the proposed methodology are presented. The IEEE 14, 30 and 57 bus systems with different measurement scenarios were used to evaluate the performance of the proposed methodology.
48

Configurador de redes baseado na representação nó-profundidade para efeito de estimação de estado / Tracking network topology processor using node-depth representation for state estimation

Piereti, Saulo Augusto Ribeiro 17 August 2007 (has links)
A modelagem em tempo real dos sistemas elétricos de potência (SEP) é extremamente importante para se obter uma operação em tempo real segura e confiável dos mesmos. O configurador de redes (CR) é uma ferramenta fundamental, para modelagem em tempo real dos SEP. A função do CR é determinar, em tempo real, a topologia atual da rede e a correspondente configuração de medidores, no modelo barra-ramo. Para isso, o configurador processa medidas lógicas, que consistem em estados de chaves e disjuntores, bem como dados armazenados em um banco de dados estático, que descreve a conexão dos equipamentos do sistema com as seções de barramento. Em razão de os CRs exigirem algoritmos de busca em um grafo, o desempenho desses algoritmos torna-se fortemente afetado pela forma com que as árvores são computacionalmente representadas. Propõe-se, neste trabalho, um CR tracking, para efeito de estimação de estado, que se baseia em uma nova forma de representar árvores, denominada representação nó-profundidade (RNP). A RNP permite um acesso direto para cada nó de um grafo e pode representar eficientemente árvores (grafos conexos e acíclicos) e florestas (um grafo com uma ou mais árvores). O CR proposto possui as seguintes características: (i) A RNP possibilita uma rápida atualização da topologia da rede, no modelo barra-ramo; (ii) Esta estrutura também permite a realização das etapas configuração de subestação e de rede ao mesmo tempo, diminuindo assim o tempo de processamento necessário para a obtenção do modelo barra-ramo. Para isso, o CR proposto representa cada seção de barramento do SEP como nó de um grafo e usa a RNP e outras duas estruturas de dados, que serão apresentadas no capítulo 5; (iii) Possibilita a associação dos medidores aos componentes do SEP, no modelo barra-ramo, de forma direta. Para isso, o CR proposto usa a RNP e cria barras fictícias para representar os componentes shunt do SEP. Testes realizados comprovam a eficiência e a robustez do configurador proposto tendo em vista os resultados coerentes obtidos para todos os testes, mesmo para os casos em que a mudança nos estados dos dispositivos seccionadores acarretava uma alteração drástica na rede elétrica. / On-line models of power system networks have a wide variety of critical uses, covering from security monitoring and control to market operation. Network topology processor (NTP) is a key tool in providing robust and reliable on-line model of power networks. The function of NTP is the determination of the bus/branch topology model (BBTM) of the network and the assignment of metering devices to the components of the BBTM. In order to do this, the NTP processes: logical measurements that consist of switching-device (breakers and switchers) status; as well as a static data-base describing the network connectivity in terms of bus-sections and switching-devices. Since NTPs require search algorithms for graphs, their performance can be drastically affected by the adopted computational graph representation. This work proposes a new tracking NTP for state estimation purposes, that uses a new graph representation named node-depth representation (NDR). This encoding enables a straightforward access to each one of the graph nodes and can efficiently represent trees (acyclic and connected graphs) and forests (a graph with one or more trees). The proposed tracking NTP has the following characteristics: (i) Using NDR for representation of a BBTM of the network, this NTP can track, over time, the changes of the network connectivity in a very direct and fast way; (ii) Processes both steps substation and network configurations in the same time, reducing the CPU time necessary to obtain the BBTM. In order to do this, the proposed NTP represents each bus-section as a graph node and uses NDR and other two data structures, which will be presented in the chapter 5; and (iii) To assign metering devices to the components of the BBTM, in a straightforward way, the proposed NTP creates additional buses, called fictitious buses, to represent shunt devices. The results of several tests have shown the proposed NTP is reliable, fast and suitable for real-time operation.
49

Estimação de estado em sistemas elétricos de potência: programa para análise e atualização das características qualitativas de conjunto de medidas / Power system state estimation: computer program for analysis and updating of measurement set qualitative characteristics

Moreira, Eduardo Marmo 23 October 2006 (has links)
Para obter-se uma operação segura dos sistemas elétricos de potência (SEP), é imprescindível uma estimação de estado (EE) confiável, pois, as ações de controle e operação, em tempo real, dos SEP se baseiam no banco de dados obtido pelo processo de EE. O primeiro passo, para o sucesso do processo de EE, é a obtenção de um plano de medição confiável, ou seja, um plano de medição que garanta a observabilidade do sistema e a não presença de medidas críticas e dos conjuntos críticos de medidas. Entretanto, tendo em vista a possibilidade de ocorrer, durante a operação de um SEP, de problemas causando a perda de medidas, a obtenção de um plano de medição confiável é uma condição necessária, mas não suficiente, para o sucesso do processo de EE. Face ao exposto, desenvolveu-se neste trabalho um programa computacional que possibilita uma EE confiável mesmo em situação de perda de medidas. O programa proposto permite, de uma forma rápida em termos de velocidade de execução, análise e restauração da observabilidade, identificação de medidas críticas e de conjuntos críticos de medidas, bem como a atualização dessas características qualitativas de conjunto de medidas após a perda de medidas. Como embasamento teórico para o desenvolvimento do programa proposto, foram utilizados dois algoritmos destinados à análise das características qualitativas de conjuntos de medidas, que se baseiam na fatoração triangular da matriz Jacobiana, bem como técnicas de esparsidade e de desenvolvimento de programas computacionais. Para comprovar a eficiência do programa proposto, vários testes foram realizados, utilizando o sistema de 6, 14 e 30 barras do IEEE e 121 barras da ELETROSUL. / To obtain a safe power system (PS) operation, becomes necessary a reliable state estimation (SE), since the real time control actions of a PS are based on the data obtained through the SE process. The first requirement for a successful SE process is the existence of a reliable measurement placement plan, that is, a measurement placement plan that guarantees system observability and the absence of both critical measurements and critical sets. However, considering that during the operation of a PS measurements can be lost decreasing the measurement-redundancy, one can say that although a reliable measurement placement plan is a necessary condition to guarantee a reliable state estimation, it is not sufficient. This dissertation presents a computer program that allows for a reliable SE, even in situations of problems causing loss of measurements. The proposed software allows, in a very fast way in terms of execution time, observability analysis and restoration, identification of critical measurements and critical sets, as well as the updating of these measurement set qualitative characteristics after loss of measurements. As a theoretical background for the development of the software, two algorithms were utilized allowing for the analysis of measurement set qualitative characteristics based on the triangular factorization of the Jacobian matrix, as well as sparsity techniques and techniques for the development of programs. To prove the efficiency of the proposed software, several tests were performed using the system of 6, 14 and 30 buses from IEEE and 121 buses from ELETROSUL.
50

VG2E: ferramenta computacional para visualização gráfica / VG2E: computational tool for visualization graphics

José Carlos Menezes Salgado 26 February 2010 (has links)
Propõem-se desenvolver uma ferramenta computacional voltado a objeto que permita a visualização gráfica, de forma amigável, dos resultados da dissertação de mestrado: Sistema de avaliação da qualidade e redundância das medidas para estimação de estados em sistemas elétricos de potência. A ferramenta foi desenvolvida na plataforma Windows utilizando o Microsoft C Sharp no ambiente DotNet. Os testes foram executados em resultados em redes de 14 barras. Este trabalho foi o passo inicial para elaborar uma melhor integração das diferentes dissertações num ambiente computacional moderno, cuja visualização dos resultados seja de forma mais didática e objetiva. / This paper objects develop a user friendly, object oriented, graphic computational, tool, using the output results of the paper: Sistema de avaliação da qualidade e redundância das medidas para estimação de estados em sistemas elétricos de potência. The tool was developed on Windows platform, using Microsoft C Sharp in DotNet environment. The tests were performed using numbers of networks of 14 bars. This work was the first step to develop a better integration of dissertations in a modern computing environment, which is the viewing DSO results in a more intuitive and objective.

Page generated in 0.0965 seconds