• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 6
  • Tagged with
  • 6
  • 6
  • 6
  • 6
  • 6
  • 6
  • 4
  • 4
  • 4
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Modelos numéricos de pilares mistos curtos de seções circulares de aço preenchidos com concreto em situação de incêndio / Nonlinear numerical analysis of circular concrete filled steel short columns under fire condition

Santos, Rodrigo Tadeu dos 05 March 2009 (has links)
Os pilares mistos de aço preenchidos com concreto, quando submetidos a elevadas temperaturas, apresentam comportamento estrutural bastante satisfatório e reduzem no concreto o fenômeno denominado spalling, devido ao confinamento imposto pelo tubo de aço, mais pronunciado em seções tubulares circulares. Destaca-se ainda a reduzida taxa de aquecimento desse mesmo elemento misto em razão da baixa condutividade térmica do concreto, aspecto de grande interesse para fins de dimensionamento. O presente trabalho tem como principal objetivo modelar numericamente, em campo tridimensional, pilares mistos curtos com seções tubulares circulares de aço, preenchidos com concreto e submetidos ao incêndio-padrão prescrito pela ISO 834:1999. A modelagem se faz com vistas a simular o comportamento estrutural desse elemento em situação de incêndio, buscando avaliar a influência da elevação de temperatura na resistência do elemento e indicar para qual tempo e em que níveis de temperatura o acréscimo de resistência devido ao efeito do confinamento deixa de ser pronunciado. Para a modelagem numérica em campos térmico, estrutural e termo-estrutural, se utiliza o pacote comercial ANSYS ® V9.0, elaborado com base no método dos elementos finitos, o qual permite a análise transiente dos efeitos do gradiente térmico nos elementos estruturais. Os resultados das análises térmica, estrutural e acoplada são previamente comparados com valores obtidos com o código computacional TCD 5.5. A análise acoplada foi realizada para três diâmetros de pilares mistos, e as variações do diâmetro e da resistência à compressão do concreto foram consideradas, possibilitando uma análise paramétrica. Por fim, é apresentada uma análise inversa dos modelos, considerando carregamentos crescentes para campos de temperatura fixos. / Concrete-filled steel columns when subjected to high temperatures present satisfactory structural behavior and the reduction of the spalling phenomenon in the concrete due to confinement action of the steel tube, more notable in circular cross sections. Another advantage is the reduced heating rate of this element due to concrete low thermal conductivity, which is an interesting characteristic in designing procedures. The aim of this work is to develop 3D numerical models of circular concrete-filled steel short columns under fire exposure according to the ISO-834:1999 standard. The numerical models are developed to simulate the structural behavior of those composite short columns under fire condition, in order to evaluate the influence of increasing temperature in the strength of the structural element. This makes possible define the time and the temperature level in which the resistant increment due to the confinement effect is no more appreciable. To perform the numerical model of thermal, structural and thermal-structural fields, a commercial finite element analysis package ANSYS ® V9.0 is used, which allows transient analysis of the thermal gradient effects in the structural elements. The results from thermal, structural and coupled analyses are previously compared with the ones obtained with TCD 5.5 package. The coupled analysis is performed for three different columns, changing the diameter and concrete compression strength to be used in a parametric analysis. Finally, it is shown another analysis type, called reverse analysis, which considers increasing structural loads for fixed temperature fields.
2

Modelagem do comportamento estrutural de sistemas treliçados espaciais para escoramentos de estruturas de aço, concreto e mistas (aço-concreto). / Modeling behavior lattice structures systems for shorring of steel, concrete and composite structures (steel - concrete).

Miguel Henrique de Oliveira Costa 03 May 2012 (has links)
A utilização de treliças para o escoramento de elementos estruturais de concreto armado e aço é considerada uma solução eficaz para o atual sistema de construção de engenharia civil. Uma mudança de atitude no processo de construção, associado com a redução dos custos causou um aumento considerável na utilização de treliças tridimensionais em aço com maior capacidade de carga. Infelizmente, o desenho destes sistemas estruturais baseia-se em cálculos muito simplificados relacionadas com vigas de uma dimensão, com propriedades de inércia constantes. Tal modelagem, muito simplificada, não pode representar adequadamente a resposta real dos modelos estruturais e pode levar a inviabilidade econômica ou mesmo inseguro desenho estrutural. Por outro lado, estas estruturas treliçadas estão relacionadas com modelos de geometria complexa e são desenhados para suportar níveis de cargas muito elevadas. Portanto, este trabalho de investigação propôs modelos de elementos finitos que representam o caráter tridimensional real do sistema de escoramento, avaliando o comportamento estático e dinâmico estrutural com mais confiabilidade e segurança. O modelo computacional proposto, desenvolvido para o sistema estrutural não linear de análise estática e dinâmica, aprovou as habituais técnicas de refinamento de malha presentes em simulações do método de elementos finitos, com base no programa ANSYS [1]. O presente estudo analisou os resultados de análises linear-elástica e não linear geométrica para ações de serviço, físicos e geométricos para as ações finais. Os resultados do presente estudo foram obtidas, com base na análise linear-elástica e não linearidade geométrica e física, e comparados com os fornecidos pela metodologia simplificada tradicional de cálculo e com os limites recomendadas por normas de concepção. / The use of lattice structures for shoring of steel, composite and reinforced concrete structures is considered an effective solution in the construction of civil engineering systems. An attitudinal change in the construction process associated with costs reduction has caused a considerable increase in the use of three-dimensional lattice steel truss systems with greater load capacity. Unfortunately, the design of these structural systems is based on very simplified calculations related to one-dimensional beams with constant inertia properties. Such a very simplified modeling cannot adequately represent the actual response of the structural models and can lead to uneconomic or even unsafe structural design. On the other hand, these lattice steel structures are related to three-dimensional models of complex geometry and are designed to support very high loading levels. Therefore, this work research has proposed finite element models that represent the actual three-dimensional character of shoring system, evaluating the static and dynamic structural behavior with more reliability and security. The proposed computational model, developed for the structural system non-linear static and dynamic analysis, adopted the usual mesh refinement techniques present in finite element method simulations, based on the Annoys program. The present study has considered the results of a linear-elastic and non-linear geometric analysis for serviceability actions, physical and geometrical nonlinear analysis for ultimate actions. The results of the present investigation were obtained, based on linear-elastic and non-linear geometric and physical analysis, and compared with those supplied by the traditional simplified methodology of calculation and with the limits recommended by design standards.
3

Modelagem do comportamento estrutural de sistemas treliçados espaciais para escoramentos de estruturas de aço, concreto e mistas (aço-concreto). / Modeling behavior lattice structures systems for shorring of steel, concrete and composite structures (steel - concrete).

Miguel Henrique de Oliveira Costa 03 May 2012 (has links)
A utilização de treliças para o escoramento de elementos estruturais de concreto armado e aço é considerada uma solução eficaz para o atual sistema de construção de engenharia civil. Uma mudança de atitude no processo de construção, associado com a redução dos custos causou um aumento considerável na utilização de treliças tridimensionais em aço com maior capacidade de carga. Infelizmente, o desenho destes sistemas estruturais baseia-se em cálculos muito simplificados relacionadas com vigas de uma dimensão, com propriedades de inércia constantes. Tal modelagem, muito simplificada, não pode representar adequadamente a resposta real dos modelos estruturais e pode levar a inviabilidade econômica ou mesmo inseguro desenho estrutural. Por outro lado, estas estruturas treliçadas estão relacionadas com modelos de geometria complexa e são desenhados para suportar níveis de cargas muito elevadas. Portanto, este trabalho de investigação propôs modelos de elementos finitos que representam o caráter tridimensional real do sistema de escoramento, avaliando o comportamento estático e dinâmico estrutural com mais confiabilidade e segurança. O modelo computacional proposto, desenvolvido para o sistema estrutural não linear de análise estática e dinâmica, aprovou as habituais técnicas de refinamento de malha presentes em simulações do método de elementos finitos, com base no programa ANSYS [1]. O presente estudo analisou os resultados de análises linear-elástica e não linear geométrica para ações de serviço, físicos e geométricos para as ações finais. Os resultados do presente estudo foram obtidas, com base na análise linear-elástica e não linearidade geométrica e física, e comparados com os fornecidos pela metodologia simplificada tradicional de cálculo e com os limites recomendadas por normas de concepção. / The use of lattice structures for shoring of steel, composite and reinforced concrete structures is considered an effective solution in the construction of civil engineering systems. An attitudinal change in the construction process associated with costs reduction has caused a considerable increase in the use of three-dimensional lattice steel truss systems with greater load capacity. Unfortunately, the design of these structural systems is based on very simplified calculations related to one-dimensional beams with constant inertia properties. Such a very simplified modeling cannot adequately represent the actual response of the structural models and can lead to uneconomic or even unsafe structural design. On the other hand, these lattice steel structures are related to three-dimensional models of complex geometry and are designed to support very high loading levels. Therefore, this work research has proposed finite element models that represent the actual three-dimensional character of shoring system, evaluating the static and dynamic structural behavior with more reliability and security. The proposed computational model, developed for the structural system non-linear static and dynamic analysis, adopted the usual mesh refinement techniques present in finite element method simulations, based on the Annoys program. The present study has considered the results of a linear-elastic and non-linear geometric analysis for serviceability actions, physical and geometrical nonlinear analysis for ultimate actions. The results of the present investigation were obtained, based on linear-elastic and non-linear geometric and physical analysis, and compared with those supplied by the traditional simplified methodology of calculation and with the limits recommended by design standards.
4

Modelos numéricos de pilares mistos curtos de seções circulares de aço preenchidos com concreto em situação de incêndio / Nonlinear numerical analysis of circular concrete filled steel short columns under fire condition

Rodrigo Tadeu dos Santos 05 March 2009 (has links)
Os pilares mistos de aço preenchidos com concreto, quando submetidos a elevadas temperaturas, apresentam comportamento estrutural bastante satisfatório e reduzem no concreto o fenômeno denominado spalling, devido ao confinamento imposto pelo tubo de aço, mais pronunciado em seções tubulares circulares. Destaca-se ainda a reduzida taxa de aquecimento desse mesmo elemento misto em razão da baixa condutividade térmica do concreto, aspecto de grande interesse para fins de dimensionamento. O presente trabalho tem como principal objetivo modelar numericamente, em campo tridimensional, pilares mistos curtos com seções tubulares circulares de aço, preenchidos com concreto e submetidos ao incêndio-padrão prescrito pela ISO 834:1999. A modelagem se faz com vistas a simular o comportamento estrutural desse elemento em situação de incêndio, buscando avaliar a influência da elevação de temperatura na resistência do elemento e indicar para qual tempo e em que níveis de temperatura o acréscimo de resistência devido ao efeito do confinamento deixa de ser pronunciado. Para a modelagem numérica em campos térmico, estrutural e termo-estrutural, se utiliza o pacote comercial ANSYS ® V9.0, elaborado com base no método dos elementos finitos, o qual permite a análise transiente dos efeitos do gradiente térmico nos elementos estruturais. Os resultados das análises térmica, estrutural e acoplada são previamente comparados com valores obtidos com o código computacional TCD 5.5. A análise acoplada foi realizada para três diâmetros de pilares mistos, e as variações do diâmetro e da resistência à compressão do concreto foram consideradas, possibilitando uma análise paramétrica. Por fim, é apresentada uma análise inversa dos modelos, considerando carregamentos crescentes para campos de temperatura fixos. / Concrete-filled steel columns when subjected to high temperatures present satisfactory structural behavior and the reduction of the spalling phenomenon in the concrete due to confinement action of the steel tube, more notable in circular cross sections. Another advantage is the reduced heating rate of this element due to concrete low thermal conductivity, which is an interesting characteristic in designing procedures. The aim of this work is to develop 3D numerical models of circular concrete-filled steel short columns under fire exposure according to the ISO-834:1999 standard. The numerical models are developed to simulate the structural behavior of those composite short columns under fire condition, in order to evaluate the influence of increasing temperature in the strength of the structural element. This makes possible define the time and the temperature level in which the resistant increment due to the confinement effect is no more appreciable. To perform the numerical model of thermal, structural and thermal-structural fields, a commercial finite element analysis package ANSYS ® V9.0 is used, which allows transient analysis of the thermal gradient effects in the structural elements. The results from thermal, structural and coupled analyses are previously compared with the ones obtained with TCD 5.5 package. The coupled analysis is performed for three different columns, changing the diameter and concrete compression strength to be used in a parametric analysis. Finally, it is shown another analysis type, called reverse analysis, which considers increasing structural loads for fixed temperature fields.
5

Análise da resposta dinâmica experimental de uma passarela tubular mista, aço-concreto, submetida ao caminhar humano. / Experimental analysis of dynamic response of a tubular composite steel-concrete footbridge, submitted to human walking.

José Eduardo Villarroel Zúñga 19 July 2011 (has links)
Este trabalho de pesquisa apresenta como objetivo principal o desenvolvimento de investigação experimental dinâmica sobre estrutura real de uma passarela tubular mista aço-concreto. O sistema estrutural objeto deste trabalho corresponde a uma passarela composta por três vãos (32,5m, 17,5m e 20,0m, respectivamente) e dois balanços (7,50m e 5,0m, respectivamente), com comprimento total de 82,5m. A passarela com estrutura contínua de aço com as ligações soldadas se apoia em quatro pórticos também de aço. Estruturalmente está constituída por duas treliças planas que se interligam através de contraventamentos horizontais fixados na corda superior e inferior da treliça e lajes de concreto, formando um sistema misto com interação completa. A estrutura está submetida correntemente à travessia de pedestres e ciclistas. Testes experimentais foram realizados sobre o sistema estrutural e confrontados com resultados numéricos. Para a modelagem numérica do sistema são empregadas técnicas usuais de discretização, via método dos elementos finitos (MEF), por meio do programa ANSYS. Os resultados experimentais são analisados de acordo com a metodologia desenvolvida, sendo realizada análise modal experimental para a determinação das propriedades dinâmicas: freqüências, modos e taxa de amortecimento, enquanto que os resultados da estrutura, em termos de aceleração de pico, são comparados com os valores limites propostos por diversos autores, normas e recomendações de projeto, para uma avaliação do desempenho da estrutura em relação a vibração quando solicitada pelo caminhar dos pedestres no que diz respeito a critério para conforto humano. / This research has as main objective the development of a dynamical experimental investigation of a real structure a tubular composite steel-concrete footbridge. The structural system of this study corresponds to a footbridge composed by three spans (32,5m, 17,5m and 20,0m, respectively) and two overhangs (7,50m and 5,0m, respectively), spanning 82,5m. The investigated structural model is composed by a continuous tubular steel structure with welded connections supported by four double file steel columns. It is structurally composed of two plane trusses are intertwined by horizontal bracing set in upper and lower chord of the truss and slabs of concrete, forming effective composite with complete interaction. This structure is currently submitted to pedestrians and cyclists crossing. Experimental tests were carried out on the structural system and with the numerical results. For the numerical modeling, discretization techniques via finite element method were applied, based on the ANSYS program. The experimental results were analyzed according to the developed methodology, and a modal analysis was implemented to determine the dynamical properties: frequencies, mode shapes and modal damping ratio, while the structure results in terms of peak acceleration, was obtained and compared to the limit values proposed by several authors and design recommendations, for the structure performance by pedestrian walking regarding the acceptance criteria for human comfort.
6

Análise da resposta dinâmica experimental de uma passarela tubular mista, aço-concreto, submetida ao caminhar humano. / Experimental analysis of dynamic response of a tubular composite steel-concrete footbridge, submitted to human walking.

José Eduardo Villarroel Zúñga 19 July 2011 (has links)
Este trabalho de pesquisa apresenta como objetivo principal o desenvolvimento de investigação experimental dinâmica sobre estrutura real de uma passarela tubular mista aço-concreto. O sistema estrutural objeto deste trabalho corresponde a uma passarela composta por três vãos (32,5m, 17,5m e 20,0m, respectivamente) e dois balanços (7,50m e 5,0m, respectivamente), com comprimento total de 82,5m. A passarela com estrutura contínua de aço com as ligações soldadas se apoia em quatro pórticos também de aço. Estruturalmente está constituída por duas treliças planas que se interligam através de contraventamentos horizontais fixados na corda superior e inferior da treliça e lajes de concreto, formando um sistema misto com interação completa. A estrutura está submetida correntemente à travessia de pedestres e ciclistas. Testes experimentais foram realizados sobre o sistema estrutural e confrontados com resultados numéricos. Para a modelagem numérica do sistema são empregadas técnicas usuais de discretização, via método dos elementos finitos (MEF), por meio do programa ANSYS. Os resultados experimentais são analisados de acordo com a metodologia desenvolvida, sendo realizada análise modal experimental para a determinação das propriedades dinâmicas: freqüências, modos e taxa de amortecimento, enquanto que os resultados da estrutura, em termos de aceleração de pico, são comparados com os valores limites propostos por diversos autores, normas e recomendações de projeto, para uma avaliação do desempenho da estrutura em relação a vibração quando solicitada pelo caminhar dos pedestres no que diz respeito a critério para conforto humano. / This research has as main objective the development of a dynamical experimental investigation of a real structure a tubular composite steel-concrete footbridge. The structural system of this study corresponds to a footbridge composed by three spans (32,5m, 17,5m and 20,0m, respectively) and two overhangs (7,50m and 5,0m, respectively), spanning 82,5m. The investigated structural model is composed by a continuous tubular steel structure with welded connections supported by four double file steel columns. It is structurally composed of two plane trusses are intertwined by horizontal bracing set in upper and lower chord of the truss and slabs of concrete, forming effective composite with complete interaction. This structure is currently submitted to pedestrians and cyclists crossing. Experimental tests were carried out on the structural system and with the numerical results. For the numerical modeling, discretization techniques via finite element method were applied, based on the ANSYS program. The experimental results were analyzed according to the developed methodology, and a modal analysis was implemented to determine the dynamical properties: frequencies, mode shapes and modal damping ratio, while the structure results in terms of peak acceleration, was obtained and compared to the limit values proposed by several authors and design recommendations, for the structure performance by pedestrian walking regarding the acceptance criteria for human comfort.

Page generated in 0.0886 seconds