• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 20
  • 5
  • 2
  • Tagged with
  • 28
  • 28
  • 28
  • 21
  • 20
  • 13
  • 11
  • 11
  • 11
  • 11
  • 11
  • 10
  • 10
  • 9
  • 9
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Etude de la contamination par le mercure dans les milieux aquatiques : devenir et comportement biogéochimique, mise au point de méthodes d’analyse de trace du mercure / Study of mercury contamination in aquatic environments : fate and biogeochemical behavior, development of analytical methods for trace mercury analysis

Daye, Mirna 02 October 2013 (has links)
Le mercure est un élément très particulier connu par sa densité et sa pression de vapeur élevé. C’est un élément omniprésent dans l'environnement et considéré comme un polluant mondial. Dans les eaux naturelles, le mercure est présent à des concentrations très faibles. Pour cette raison, un grand nombre de techniques analytiques ne permettent pas sa mesure directe, ce qui nécessite souvent une étape de préconcentration. La première partie de cette étude est axée sur le développement des méthodes analytiques pour la mesure du mercure par extraction en phase solide. Deux méthodes analytiques ont été développées, une technique basée sur le mécanisme d'échange d'anions en utilisant l'ICP-MS (Inductively Coupled Plasma Mass Spectrometry) et Une autre basée sur l'extraction en phase solide de mercure en utilisant le 5-phenylazo-8-hydroxyquinoline et la détection par CV-AFS (Cold Vapor Atomic Fluorescence Spectroscopy). La dernière partie de ce travail est consacrée à l’étude de la distribution et le comportement biogéochimique du mercure dans les rivières de la Deûle et de la Lys (Nord de France). Les résultats obtenus montrent des concentrations élevées en mercure total (HgT) dans la Deûle, site contaminé par les activités de l'ancienne fonderie "Metaleurop". Les concentrations mesurées dans la Lys sont beaucoup plus faibles. Bien que les sédiments de la Deûle soient très chargés par HgT par rapport aux sédiments de la Lys, des pourcentages de methylmercure beaucoup plus élevés ont été trouvées dans la Lys. / Mercury is a very particular element conferred by its high density and vapor pressure. It is a ubiquitous element in the environment and considered as global pollutant. Mercury is among the most hazardous environmental pollutants, given by its organic form, methylmercury (MeHg or CH3Hg). In natural waters, mercury is present at very low concentrations. For this reason, most analytical techniques do not achieve accurate direct measurement of Hg which necessitates preconcentration to meet their limit of detection. The first part of this study focuses on the development of analytical methods for the measurement of mercury by solid phase extraction. Two analytical methods have been developed; one based on the anion exchange mechanism using ICP-MS (Inductively Coupled Plasma Mass Spectrometry) and the other one based on the solid phase extraction of mercury using 5-phenylazo-8- hydroxyquinoline and detection by CV-AFS (Cold Vapor Atomic Fluorescence Spectroscopy). Part of this work also includes the distribution and biogeochemical behavior of mercury in rivers of the Deûle and Lys (Northern France). The results have showed high concentrations of total mercury (HgT) in the Deûle contaminated by a former smelter "Metaleurop". The concentrations of HgT measured in the Lys are much lower. Although Deûle sediments are highly burdened with HgT as compared to Lys sediments, much higher percentage of methylmercury is found in Lys River. Suspended particles are the major Hg carrier phase and transporters of Hg pollution from Deûle to Lys River.
2

Développement d'un support d'extraction sélective à base d'aptamères : synthèse, caractérisation et application à des matrices complexes

Madru, Benjamin 10 November 2010 (has links) (PDF)
L'analyse de composés à l'état de traces dans des échantillons complexes tels que les fluides biologiques, les matrices environnementales ou les denrées alimentaires nécessite une étape de purification avant analyse afin de limiter la présence d'effets de matrice. Les supports conventionnels d'extraction sur phase solide, bien qu'étant très efficaces pour préconcentrer l'échantillon, conduisent souvent à la co-extraction de composés interférents. Afin de pallier ce manque de sélectivité, des supports sélectifs fondés sur des mécanismes de reconnaissance moléculaire ont été développés. Les immunoadsorbants, reposants sur l'utilisation d'anticorps dirigés contre l'analyte et immobilisés sur un support solide, et les polymères à empreintes moléculaires qui possèdent des cavités spécifiques complémentaires d'une molécule empreinte, ont déjà démontré un fort potentiel pour l'extraction sélective de composés de matrices complexes. Un troisième type de support d'extraction sélective également fondé sur un mécanisme de reconnaissance moléculaire exploitant les propriétés des aptamères a été développé lors de cette étude. Les aptamères sont des oligonucléotides capables de fixer de manière spécifique une molécule avec une affinité comparable à celle des anticorps. Un aptamère sélectionné pour reconnaître la cocaïne a été choisi comme aptamère modèle pour cette étude de faisabilité. Différents supports d'immobilisation ont été évalués et les oligoadsorbants obtenus ont été caractérisés en termes de rétention spécifique et non spécifique, de taux de greffage, et de capacité. La sélectivité du support le plus performant en milieu pur a ensuite été évaluée en réalisant l'extraction de la cocaïne de plasma et de sang. L'analyse chromatographique des extraits obtenus a conduit à des chromatogrammes dépourvus de co-élutions, contrairement à ceux issus des traitements généralement employés, démontrant ainsi l'apport en purification de l'oligoextraction. Ce développement a ensuite été transposé avec succès à un autre aptamère, l'aptamère anti-ochratoxine A. L'oligoadsorbant obtenu s'est montré très rétentif, du fait de sa forte affinité, et a permis l'extraction sélective de l'ochratoxine A du vin. Les résultats obtenus sont très similaires à ceux obtenus avec un immunoadsorbant. De plus, les procédures d'extraction s'avèrent beaucoup plus simples à développer que pour les polymères à empreintes moléculaires.
3

Mise au point d'une méthodologie d'échantillonnage utilisant la micro-extraction sur phase solide pour la quantification de goudrons sur des procédés de thermolyse de la biomasse

Comte, Julien 31 October 2008 (has links) (PDF)
La gazéification de la biomasse par voie thermochimique apparaît aujourd'hui comme une voie prometteuse pour la production de H2 et CO utilisés dans la synthèse de biocarburants. Le traitement thermique subi par la biomasse entraîne toutefois la production de composés indésirables appelés goudrons (hydrocarbures lourds) dont la teneur dans les gaz de synthèse doit être inférieure à 0,1 mg.Nm-3. Le suivi de la quantité de goudrons produits est, par conséquent, indispensable. Dans ce contexte, une méthodologie d'échantillonnage utilisant la SPME (micro-extraction sur phase solide) a été mise au point pour la quantification de "composés types" représentatifs de la quantité globale de goudrons émis principalement par deux pilotes de gazéification et de pyrolyse. L'introduction de la notion de composés types est destinée d'une part, à simplifier la méthodologie d'échantillonnage et d'autre part, à s'affranchir des éventuelles limitations liées au système de prélèvement des effluents gazeux développé dans le cadre de ce travail pour autoriser l'extraction par SPME. Pour les deux pilotes, 15 composés types ont été retenus. Leur quantification a d'abord nécessité l'étalonnage préalable des fibres SPME (revêtue de polydimethylsiloxane) qui a permis, à plusieurs températures, d'établir les profils d'absorption et de déterminer les coefficients de partage. L'influence des conditions d'extraction sur l'absorption ainsi que les performances du couplage SPME-chromatographie gazeuse ont également été évaluées. De manière à éviter les étalonnages répétitifs, un modèle basé sur la théorie des équilibres thermodynamiques a été développé pour déterminer la valeur des coefficients de partage.
4

Développement d'outils bioanalytiques miniaturisés : greffage de biomolécules sur monolithes en capillaire couplés à la nanochromatographie pour l'analyse d'échantillons complexes / Development of miniaturized bioanalytical tools : grafting of biomolecules on monolithic capillaries coupled on-line to nanochromatography for the analysis of complex samples

Brothier, Fabien 24 October 2014 (has links)
L’analyse de traces dans des matrices complexes (environnementales, alimentaires ou biologiques) requiert très souvent une étape de purification et de préconcentration avant une analyse via des méthodes chromatographiques. Dans cette optique, des supports d’extraction basés sur des mécanismes de reconnaissance moléculaire ont été développés et appliqués à l’extraction de composés cibles rendant ainsi l’analyse plus sensible et plus fiable. Ces supports sélectifs peuvent entre autres résulter de l’immobilisation de biomolécules tels que les anticorps ou les aptamères (i.e. des oligonucléotides présentant une séquence capable de se lier spécifiquement à une molécule). Cette étape de traitement de l’échantillon est particulièrement nécessaire lorsqu’il s’agit de développer des systèmes séparatifs miniaturisés, tels que les microsystèmes séparatifs sur puce, du fait de la diminution de la résolution qui résulte de l’utilisation d’un canal de séparation de faible longueur. Dans ce contexte, ce projet de recherche a consisté à développer des systèmes bioanalytiques miniaturisés pour l’analyse de petites molécules ou protéines dans des échantillons complexes. Pour développer ces systèmes, la synthèse d’un monolithe hybride organique-inorganique in situ dans des capillaires de 100 µm d.i. a, dans un premier temps, été optimisée via une approche sol-gel puis caractérisée en termes de répétabilité. Dans une deuxième partie, deux toxines modèles de faible poids moléculaire ont été choisies : la microcystine-LR (MC-LR) et l’ochratoxine A (OTA). Des anticorps monoclonaux et des aptamères, spécifiques de l’une et l’autre des toxines ont ensuite été greffés sur des monolithes en capillaire. Les immuno- et oligoadsorbants miniaturisés obtenus (respectivement mIS et mOS) ont été couplés en ligne avec la nanoLC. La rétention spécifique des toxines cibles sur les mIS et mOS a été démontrée dans l’eau pure. La répétabilité de la synthèse et du greffage a été évaluée et la capacité de chacun des supports miniaturisés a été déterminée. Enfin, mIS et mOS ont été appliqués avec succès à l’extraction sélective de la MC-LR et de l’OTA à partir d’extraits de cultures de cyanobactéries, d’eaux environnementales ainsi que d’échantillons de bière dopés. Dans un troisième temps, de façon à transposer les outils sélectifs développés à l’analyse de protéines, des microréacteurs enzymatiques (IMER) ont été préparés par greffage de deux enzymes protéolytiques (pepsine et trypsine) sur des monolithes. Ces outils ont ensuite été couplés avec la nanoLC-MS² pour l’analyse d’une protéine modèle, le cytochrome C. Les rendements de digestion sur IMER se sont avérés présenter une bonne répétabilité. Toutefois, l’efficacité de la digestion sur les IMER à base de pepsine reste à ce jour insuffisante et nécessite de réadapter la procédure de greffage et/ou de digestion. / The analysis of ultra-traces from complex matrices (environmental, foodstuff or biological) often requires a step of purification and preconcentration before their analysis by chromatographic separation methods. Therefore, extraction sorbents based on a molecular recognition mechanism can be developed and used for the selective extraction of target molecules thus rendering their quantitative analysis in complex samples more reliable and sensitive. These extraction sorbents may result, among others, from the immobilization of biomolecules such as antibodies and aptamers (i.e. oligonucleotides whose sequence is specific for a target molecule). This selective sample pretreatment step is particularly necessary when developing miniaturized devices such as separative microsystems on chip because of the decrease of the resolution that results from the use of a shorter length separation channel. In this context, the aim of our study was to develop miniaturized bioanalytical devices for the analysis of small molecules or proteins in complex samples. For the development of these devices, in-situ synthesis of a porous hybrid organic-inorganic monolith in capillaries (100 µm i.d.) by sol-gel approach was firstly optimized and characterized in terms of repeatability. Secondly, two model toxins of low molecular weight were chosen: microcystin-LR (MC-LR) and ochratoxin A (OTA). Monoclonal antibodies and aptamers specific to one and the other target molecules were then grafted on the monolithic capillaries. The resulting miniaturized immunosorbent (mIS) and oligosorbent (mOS) were then coupled on-line to nanoLC. Specific retention of MC-LR and OTA on the mIS and the mOS, respectively, was demonstrated in pure water. Synthesis repeatability and capacity of the miniaturized sorbents were evaluated. Finally, these miniaturized tools were applied to the selective extraction of MC-LR or OTA from complex samples, i.e. blue-green algae extracts, environmental waters or beer. In a third part, immobilized enzyme reactors (IMERs) were prepared by grafting two proteolytic enzymes (pepsin and trypsin) on monoliths in order to transpose the developed selective tools to the analysis of proteins. These IMERs were then coupled on-line to nanoLC-MS² for the analysis of a model protein, cytochrome C. Digestion yields on IMERs presented a good repeatability. However, digestion efficiency on the pepsin-based IMERs remains so far insufficient and grafting or digestion procedure needs to be readjusted.
5

Développement de nouvelles méthodes séparatives compatibles avec une détection par spectrométrie de masse et par électrochimie pour l'analyse de traces de catécholamines et molécules apparentées / Development of new chromatographic methods compatibles with mass spectrometric detection and electrochemical detection for catecholamines and related molecules

Chirita, Raluca-Ioana 27 November 2009 (has links)
Les catécholamines et les indolamines font partie de la famille des neurotransmetteurs. Un déséquilibre dans leur concentration peut être associé à différentes maladies telles les maladies de Parkinson et Alzheimer, la dépression ou la schizophrénie. C’est pourquoi le développement de méthodes de dosage spécifiques et très sensibles du fait de leurs très faibles teneurs dans les fluides biologiques est nécessaire. Dans un premier temps nous avons développé une méthode chromatographique en appariement d’ions (IP-LC) utilisant des colonnes C18 de nouvelle génération (monolithique et « fused core ») et l’acide nonafluoropentanoïque, comme agent d’appariement d’ions volatil. Cette méthode est compatible avec une détection SM en mode d’ionisation positive. Dans un deuxième temps, différents systèmes en mode HILIC ont été évalués. Le choix raisonné de la phase stationnaire offrant la meilleure séparation du mélange de catécholamines a pu être réalisé après avoir testé l’influence sur la séparation des différents groupements fonctionnels disponibles : groupement soit neutre (greffage diol, amide, ou cyano), soit positivement chargé (greffage amino ou triazole) soit négativement chargé (silice vierge avec particules totalement poreuses ou partiellement poreuses « fused core ») ou zwitterionique (greffage sulfobetaïne). La méthode HILIC présente l’avantage d’être compatible aussi bien avec une détection SM en mode d’ionisation positive que négative. Les deux méthodes (IP-LC et HILIC) ont été comparées en termes de résolution, efficacité et limites de détection (LOD), linéarité et répétabilité. Les LODs obtenues sont comprises entre 1 et 100 ng.mL-1. Pour pouvoir doser des teneurs plus faibles, une méthode de pré-concentration de l’échantillon a été développée en associant 2 supports différents (Oasis HLB et PGC). La méthode optimisée SPE-CPL-MS/MS a été enfin appliquée à un extrait de cerveau de mouton. / As neurotransmitters, catecholamines play an important role in the control and regulation of numerous brain functions. They are also believed to be implicated in different neurodegenerative disorders. First an ion pairing chromatography method using nonafluoropentanoic acid as volatile ion paring agent was developed on the new generation of C18 columns (monolith and fused core). This method is compatible with MS detection in positive ionization mode. Secondly an HILIC method was optimized using different commercially available HILIC supports, they can be classified as follows: neutral (diol, amide, and cyano bounded), positively charged (amino, triazole bounded), negatively charged (bare silica as wholly porous particles or fused core particles columns) and zwitterionic (sulfobetaine bounded). Our studies lead us to a better understanding of the HILIC retention mechanism and also to the selection of the most appropriated column for catecholamine analysis. Only the HILIC system was compatible with both positive and negative ionization modes. The two chromatographic systems were then compared in terms of resolution, efficiency, detection and quantification limits (LOD/LOQ), calibration linearity and repeatability. The LODs obtained were in the range of 1-100 ng.mL-1. A simple pre-concentration method using Oasis HLB and PGC solid phase extraction cartridges has been optimized in order to enhance the LODs. Finally the optimized SPE-LC-MS/MS method has been applied to the identification of these compounds present in brain extracts.
6

Développement de polymères à empreintes ioniques pour l'extraction sélective des lanthanides dans des échantillons environnementaux / Development of ion imprinted polymers for the selective extraction of lanthanides from environmental samples

Moussa, Manel 20 September 2016 (has links)
L'analyse des lanthanides à l'état de trace dans les matrices environnementales requiert souvent une étape de purification et de préconcentration. L'extraction sur phase solide (SPE) est la technique la plus utilisée dans le domaine du traitement de l'échantillon. Cette thèse a consisté à développer des polymères à empreintes ioniques (IIP) pour l'extraction sélective des lanthanides (Ln3+). Tout d'abord, des IIP ont été préparés selon l'approche de piégeage en utilisant le 5,7-dichloroquinoline-8-ol, un ligand non vinylique. La perte de ce ligand, supposé piégé, durant les étapes d'élimination de l'ion empreinte et de sédimentation succédant à la polymérisation a été démontrée en HPLC-UV. Cette perte non répétable a entraîné un manque de répétabilité des profils SPE sur deux IIP préparés dans les mêmes conditions. Cela a permis de démontrer que cette approche de synthèse pour des IIP n'était pas adéquate. Ensuite, des IIP ont été synthétisés par immobilisation chimique en utilisant l'acide méthacrylique comme monomère vinylique. La répétabilité des étapes de synthèse et d'extraction a été démontrée. Une sélectivité pour l'ensemble des lanthanides a été obtenue et des applications avec des échantillons réels ont été faites avec succès. Enfin, des IIP obtenus par immobilisation chimique d'acide méthacrylique et de 4-vinylpyridine comme monomères ont été synthétisés avec comme ion empreinte soit un Ln3+ léger (Nd3+) soit un Ln3+ lourd (Er3+). Des sélectivités identiques de ces IIP pour l'ensemble des Ln3+ ont été obtenues dans les deux cas. Cependant, cette sélectivité a pu être modulée en changeant la nature et le pH de la solution de lavage utilisée dans le protocole SPE. / The analysis of the lanthanide ions present at trace level in complex environmental matrices requires often a purification and preconcentration step. The solid phase extraction (SPE) is the most used sample preparation technique. To improve the selectivity of this step, Ion Imprinted Polymers (IIPs) can be used as SPE solid supports. The aim of this work was the development of IIPs for the selective extraction of lanthanide ions from environmental samples. In a first part, IIPs were prepared according to the trapping approach using 5,7-dichloroquinoline-8-ol as non-vinylated ligand. For the first time, the loss of the trapped ligand during template ion removal and sedimentation steps was demonstrated by HPLC-UV. Moreover, this loss was not repeatable, which led to a lack of repeatability of the SPE profiles. It was then demonstrated that the trapping approach is not appropriate for the IIPs synthesis.In a second part, IIPs were synthesized by chemical immobilization of methacrylic acid as vinylated monomer. The repeatability of the synthesis and the SPE protocol were confirmed. A good selectivity of the IIPs for all the lanthanide ions was obtained. IIPs were successfully used to selectively extract lanthanide ions from tap and river water. Finally, IIPs were synthesized by chemical immobilization of methacrylic acid and 4-vinylpyridine as functional monomers and either a light (Nd3+) or a heavy (Er3+) lanthanide ion as template. Both kinds of IIPs led to a similar selectivity for all lanthanide ions. Nevertheless, this selectivity can be modified by changing the nature and the pH of the washing solution used in the SPE protocol.
7

Optimisation de techniques analytiques pour caractériser les antibiotiques dans les systèmes aquatiques / Analytical methodologies optimisation for antibiotics determination in aqueous systems

Mokh, Samia 13 December 2013 (has links)
Les antibiotiques sont des polluants présents dans les écosystèmes aquatiques, réceptacles ultimes des substances anthropiques. L’étude de ces composés porte sur leur rémanence dans le milieu ou leurs effets sur des organismes naturels. De nombreux efforts ont été faits à l’échelle mondiale pour l’évaluation de la qualité environnementale des différentes ressources en eau pour la survie des espèces aquatiques mais aussi pour la consommation humaine et le risque sanitaire lié. Dans ce but, l’optimisation des techniques analytiques pour ces composés dans les systèmes aquatiques demeure une nécessité. Notre objectif est de développer des méthodes d’extraction et de détection pour 12 molécules appartenant à la famille des aminoglycosides et de la colistine dans les eaux des stations d’épuration et les eaux hospitalières. L’absence des méthodes d’analyse pour ces composés ainsi que le manque des études permettant leur détection dans l’eau sont les raisons de leur étude. L’Extraction sur Phase Solide (SPE) en mode classique (hors ligne) ou en ligne, suivie d’une analyse par la Chromatographie Liquide couplée à la Spectrométrie de Masse (LC/MS/MS) est la méthode la plus couramment employée pour ce type d’analyse. Les paramètres sont optimisés et validés afin d’assurer les meilleures conditions utilisées dans les analyses environnementales. Cette technique a été appliquée sur des échantillons réels des eaux des stations d’épuration à Bordeaux et au Liban. / Antibiotics are pollutants present in aquatic ecosystems ultimate receptacles of anthropogenic substances. These compounds are studied as their persistence in the environment or their effects on natural organisms. Numerous efforts have been made worldwide to assess the environmental quality of different water resources for the survival of aquatic species, but also for human consumption and health risk related. Towards goal, the optimization of analytical techniques for these compounds in aquatic systems remains a necessity. Our objective is to develop extraction and detection methods for 12 molecules of aminoglycosides and colistin in sewage treatment plants and hospitals waters. The lack of analytical methods for analysis of these compounds and the deficiency of studies for their detection in water is the reason for their study. Solid Phase Extraction (SPE) in classic mode (offline) or online followed by Liquid Chromatography analysis coupled with Mass Spectrometry (LC/MS/ MS) is the most method commonly used for this type of analysis. The parameters are optimized and validated to ensure the best conditions for the environmental analysis. This technique was applied to real samples of wastewater treatment plants in Bordeaux and Lebanon.
8

Développement d’un procédé de réduction des sulfites dans les vins / Development of a method to reduce sulfites in wine

Bakaï, Marie-France 11 December 2015 (has links)
Le SO2 est un additif utilisé en oenologie pour ses propriétés antiseptiques,antioxydantes et antioxydasiques. Il est introduit dans les vins en grandes quantités en raisonde son fort pouvoir de combinaison avec les dérivés carbonylés, ce qui limite son activité. Leproblème est que les teneurs maximales de SO2 autorisées ne permettent pas toujours uneprotection suffisante du vin contre les phénomènes de refermentation. L'objectif principal dece projet était de réduire la concentration en dioxyde de soufre dans les vins en éliminant unepartie des dérivés carbonylés responsables de la combinaison bisulfitique. La méthoderetenue a été l’extraction sur phase solide (SPE). Elle fait intervenir des interactions entre unephase liquide et un support solide poreux modifié avec une fonction extractive. Les travauxantérieurs ont permis de sélectionner l’hydrazine et la sulfonylhydrazine comme agentsd’extraction. Ces fonctions ont été fixées sur des supports polymères organiques selon deuxvoies : la fonctionnalisation de résines sulfoniques commerciales et la copolymérisation ensuspension de méthacrylate de glycidyle suivie d’une fonctionnalisation. Les supports solidesobtenus ont été caractérisés afin de valider la fonctionnalisation. Ils ont ensuite été testés surdes solutions modèles du vin et le procédé a prouvé son efficacité. La présence decontaminants dans les solutions a été recherchée avant d’appliquer la méthode sur du vin. / SO2 is an additive used in enology for its antiseptic, antioxidant and antioxydasic properties. It is introduced in wines in large quantities due to its high binding power with carbonyl compounds, which limits its activity. The maximum SO2 content authorized is notalways enough to avoid fermentative phenomena during wine storage. The main objective of this project was to develop a method to reduce the sulfur dioxide concentration in wines byeliminating some of carbonyl compounds responsible for the SO2 binding. The method used was solid-phase extraction (SPE). It involves interactions between a liquid and a porous solid support modified with an extractive function. Previous work allowed to select hydrazine andsulfonylhydrazine as extractive reagents. These functions were fixed on organic polymersupports according to two routes : functionnalization of commercial sulfonic resins and suspension copolymerization of glycidyl methacrylate (followed by the functionnalization). The solid supports obtained were characterized in order to validate the functionnalization.Then selective extractions were executed on model solutions. The diminution of carbonylcompounds concentration and SO2 content was showed by those experiments. The presence of contaminants in the solutions was investigated before applying the method to wine.
9

Développement des méthodes analytiques pour la détection et la quantification de traces des HAP et de pesticides dans l'eau. Application à l'évaluation de la qualité des eaux libanaises.

Kouzayha, Abir 08 December 2011 (has links) (PDF)
La pollution des eaux est particulièrement problématique pour les pays industrialisés et les pays en développement. Des suivis environnementaux se sont alors avérés nécessaires afin de progresser dans la compréhension des origines et des conséquences de la présence de ces polluants. Parmi les polluants organiques les plus dangereux, les Hydrocarbures Aromatiques Polycycliques (HAP) et les pesticides qui peuvent se retrouver à l'état de traces dans les milieux aquatiques. Leur analyse nécessite des méthodes analytiques à la fois spécifiques et sensibles. L'Extraction sur Phase Solide (SPE) suivi d'une analyse par la Chromatographie Gazeuse couplée à la Spectrométrie de Masse (GC-MS) est la méthode la plus couramment employée. Les travaux de thèse s'inscrivent ainsi dans l'optique générale visant à développer des nouvelles méthodes analytiques pour l'extraction et l'analyse de ces deux familles de polluants organiques présents dans l'eau. Afin de pallier les contraintes classiques de la SPE, une nouvelle approche a été développée qui consiste à introduire la technique de centrifugation dans certaines étapes de la procédure SPE. La nouvelle méthode élaborée a permis de réduire considérablement le temps de préparation et d'économiser l'utilisation et le rejet des solvants organiques, en réduisant presque 10 fois les volumes nécessaires à l'obtention des rendements de récupération satisfaisants. Une méthode d'analyse par injection à température programmable (PTV) a été optimisée afin d'améliorer les seuils de détection des HAP. Cette étude a permis également d'avoir les informations sur la qualité des eaux de pluie, eaux souterraines et eaux de surface au Liban quant au niveau de leur contamination pour les HAP et les pesticides.
10

Synthèse et caractérisation de polymères à empreintes moléculaires pour l'extraction sélective de pesticides organophosphorés dans les huiles végétales / Synthesis and characterization of molecularly imprinted polymers for the selective extraction of organophosphorus pesticides from vegetable oils

Boulanouar Al Massati, Sara 26 September 2017 (has links)
L’utilisation croissante de pesticides dans l'agriculture peut entraîner de graves risques pour la santé humaine. En effet, des résidus de pesticides peuvent être retrouvés à l’état de trace dans de nombreux produits de grande consommation. Leur identification et leur analyse quantitative à l’état de trace dans des échantillons complexes, tel que les huiles végétales, constituent un défi analytique majeur. Malgré le potentiel élevé de méthodes analytiques comme la chromatographie en phase liquide couplée à la spectrométrie de masse (LC-MS/MS), l’introduction d’une étape d’extraction et de purification des extraits avant l’analyse chromatographique s’avère nécessaire. Afin d'augmenter la sélectivité de cette étape de traitement de l'échantillon, la synthèse des supports à empreintes moléculaires générant un mécanisme de reconnaissance moléculaire a été envisagé. Cette étude se concentre sur une famille de pesticides, les organophosphorés (OP), qui présentent des disparités structurales importantes et une gamme de polarité assez large (log P compris entre 0,7 et 4,7). Deux approches ont été envisagées pour la synthèse de ces supports imprimés. La première approche consiste à réaliser une polymérisation par voie radicalaire en utilisant des monomères organiques dans des solvants organiques peu polaires pour obtenir des polymères à empreintes moléculaires (MIP). La seconde approche consiste à produire les supports par voie sol-gel via l’hydrolyse puis la condensation d'organosilanes dans un milieu polaire pour produire des silices imprimées (MIS). Pour les deux approches, différentes conditions de synthèse ont été criblées en utilisant différentes molécules empreintes, monomères et solvants. La sélectivité des polymères imprimés résultants a d'abord été évaluée en étudiant les profils de rétention des OP en milieu pur. Les interactions non-spécifiques ont été évaluées en étudiant parallèlement la rétention des OP sur des supports non-imprimés (NIP/NIS) qui ont été synthétisés dans les mêmes conditions que les MIP/MIS mais sans introduire la molécule empreinte. Il est apparu que les supports MIP/MIS présentaient une complémentarité en termes d'extraction sélective des OP visés : les OP les plus polaires ont été extraits sélectivement par le MIS alors que les OP modérément polaires ont été extraits sélectivement par le MIP. La capacité de ces supports a été évaluée et se révèle adaptée à l'analyse des OP à l’état de traces dans des huiles végétales. Après avoir vérifié la répétabilité de la procédure d'extraction et des synthèses, les performances de ces supports ont été étudiées dans des milieux réels. / The increasing use of pesticides in agriculture causes serious health risks to humans. These pesticides may possibly be found in vegetable oils used as cosmetic ingredients. Their identification and reliable quantitative analysis at trace levels constitute a challenge for the safe use of such oils despite the high potential of analytical methods such as liquid chromatography coupled to mass spectrometry (LC-MS/MS). Their determination at low concentration levels in complex oil samples requires an extraction and a purification step. In order to increase the selectivity of the sample treatment step, the synthesis of imprinted sorbents can be considered. This study focusses on a group of pesticides, the organophosphorus (OPs) that present some structural disparity and belong to a wide range of polarity (log P values between 0.7 and 4.7). To produce imprinted sorbents, a first approach of synthesis consists in the radical polymerization of organic monomers in moderately polar organic solvents to obtain molecularly imprinted polymers (MIPs). The second one, the Sol-Gel approach, consists in the hydrolysis and then condensation of organosilanes in a polar medium to produce molecularly imprinted silicas (MIS). For both approaches, different conditions of synthesis were screened using different template molecules, monomers and solvents. The selectivity of the resulting imprinting polymers was first evaluated by studying the extraction profiles of OPs in pure media on MIP and MIS. The non-specific interactions were estimated by studying in parallel the retention of OPs on non-imprinted polymers synthesized in the same conditions as imprinted sorbents but in the absence of the template molecule. Both sorbents MIP/MIS present a complementarity in terms of selective extraction of the target OPs: polar OPs were extracted selectively using the MIS while moderately polar OPs were selectively extracted by the MIP. The capacity of these supports was evaluated and was consistent with the analysis of OPs at trace levels in real oil samples. After studying the repeatability of the extraction procedure and of the reliability of the syntheses, the performances of these supports were studied in real media. For this, MIP/MIS were applied to the selective extraction of OPs from different vegetable oils (almond, olive and sunflower oil) and similar results were obtained for the three different oils. Their potential in terms of ability to remove matrix interfering compounds were higher than those of the conventional method based on the use of C18 silica. The estimated limits of quantifications were lower than the Maximum Residue Levels (MRLs) established by EU Regulation 396/2005 for these compounds in oils.

Page generated in 0.1255 seconds