1 |
Investigação de diferentes estratégias de preparo de amostras de sedimentos de rio para determinação de elementos-traço por espectrometria de absorção atômicaMimura, Aparecida Maria Simões 27 February 2013 (has links)
Submitted by isabela.moljf@hotmail.com (isabela.moljf@hotmail.com) on 2016-08-08T15:32:55Z
No. of bitstreams: 1
aparecidamariasimoesmimura.pdf: 1278299 bytes, checksum: 673e59e18120184eda18db151df38037 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2016-08-09T11:53:07Z (GMT) No. of bitstreams: 1
aparecidamariasimoesmimura.pdf: 1278299 bytes, checksum: 673e59e18120184eda18db151df38037 (MD5) / Made available in DSpace on 2016-08-09T11:53:07Z (GMT). No. of bitstreams: 1
aparecidamariasimoesmimura.pdf: 1278299 bytes, checksum: 673e59e18120184eda18db151df38037 (MD5)
Previous issue date: 2013-02-27 / FAPEMIG - Fundação de Amparo à Pesquisa do Estado de Minas Gerais / A determinação de elementos-traço em sedimentos tem recebido especial atenção no campo da ecologia e química ambiental. Tais espécies não são biodegradáveis e possuem a tendência de se acumular em organismos vivos e sedimentos, contaminando assim todo o ecossistema. Assim, os sedimentos podem atuar como um reservatório destas espécies e ser utilizados para investigar o histórico de poluição em certas áreas. Dentro deste contexto, o objetivo deste estudo foi desenvolver e otimizar um método de extração assistida por ultrassom para a determinação de Cr, Cu, Zn, Cd e Pb em sedimentos por espectrometria de absorção atômica. Vários procedimentos de extração foram estudados. Para otimizar as condições do procedimento de extração foi utilizado um planejamento fatorial fracionário. As condições ótimas para a extração foram: 0,1 g de sedimento, 7,0 mL de HF concentrado, 3,0 mL de HCl concentrado, 3 h de sonicação e temperatura do banho de ultrassom igual a 60 º C. Os resultados obtidos pela calibração externa e por adição de padrão foram concordantes a 95% de confiança para todos os analitos. As temperaturas de pirólise e atomização para as determinações de Cd e Pb por GF AAS foram estudadas. Na determinação de Pb foi utilizada a mistura de modificadores químicos (Pd e Mg). O método de extração proposto apresentou resultados adequados em relação à precisão (RSD < 10% com F AAS e < 20% com GF AAS). A exatidão foi confirmada através de estudos de adição e recuperação (com resultados de 89 a 107% de recuperação) e análise dos materiais de referência certificados Buffalo River e Marine Sediment (com recuperações na faixa de 74 a 106%). Comparado ao método oficial para a digestão de amostras de sedimentos, o tempo de preparo foi menor, favorecendo assim a frequência analítica, além do uso de menor volume de ácido, reduzindo os gastos e minimizando a geração de resíduos químicos. O método foi aplicado para a análise de amostras provenientes do Rio Doce e do Córrego Igrejinha. Foram encontrados resultados abaixo do máximo permitido pela legislação para as amostras do Rio Doce para todos os analitos, com exceção do Cr, que apresentou valores próximos ao nível máximo aceitável (90 mg kg-1). Já para as amostras do Córrego Igrejinha, todos os valores encontrados foram elevados, indicando um forte impacto ambiental na região. / The determination of trace elements in sediments has being receiving special attention in the field of ecology and environmental chemistry. Such species are not biodegradable and have a tendency to accumulate in living organisms and sediments, thus contaminating the entire ecosystem. Thus, sediment may act as a reservoir of these species and can be used to investigate the history of pollution in certain areas. Within this context, the aim of this study was to develop and optimize a method of ultrasound-assisted extraction for the determination of Cr, Cu, Zn, Cd and Pb in sediments by atomic absorption spectrometry. Several extraction procedures were studied. To optimize the extraction conditions a fractional factorial design were used. The optimum conditions for extraction were: 0.1 g of sediment, 7.0 mL concentrated HF, 3.0 mL concentrated HCl, 3 h of sonication time and ultrasound bath temperature equal to 60 ° C. The results obtained by external calibration and standard additions were consistent at 95% confidence level for all analytes. The pyrolysis and atomization temperatures for the determination of Cd and Pb by GF AAS were studied. In the determination of Pb was used the chemical modifiers (Pd and Mg). The proposed extraction method showed adequate results in terms of precision (RSD < 10% with F AAS and < 20% with GF AAS). The accuracy was confirmed by spike tests (with recoveries between 89107%) and by analyzing the certified reference materials Buffalo River and Marine Sediment (with recoveries in the range of 74 to 106%). Compared to the official method for the digestion of sediment samples, the preparation time was lower, thus favoring the analytical frequency, and the use of lower volume of acid, reducing costs and minimizing the generation of waste chemicals. The method was applied to the analysis of samples from the Rio Doce and Córrego Igrejinha. About the Rio Doce samples, the results were below those maximum permitted by legislation for all analytes, with the exception of Cr, which showed alarming values, very close to the maximum acceptable level (90 mg kg-1). About the samples from Córrego Igrejinha, all values were high, indicating a strong environmental impact in the region.
|
2 |
Desenvolvimento de método para determinação de ferro, cobre e zinco em microemulsão de biodiesel por espectrometria de absorção atômica com chama / Development of method for determination of iron, copper and zinc in biodiesel by flame atomic absorption spectrometry using microemulsion as sample preparationAntunes, Greici Alves January 2016 (has links)
Este trabalho propõe o desenvolvimento de método analítico para a determinação de Fe, Cu e Zn em amostras de biodiesel por espectrometria de absorção atômica com chama (F AAS), utilizando microemulsão como preparo de amostra. Neste trabalho buscou-se, para a formação da microemulsão, o uso de um solvente orgânico menos tóxico do que o solvente usado no método de referência (ABNT NBR 15556), o uso de padrões inorgânicos para a calibração e a ausência de um surfactante. A composição da microemulsão foi estudada através de um diagrama trifásico e a composição adotada foi de 1,7 g de biodiesel, 1,1 mL de H2O/HNO3 e volume completado com propan-1-ol até 10 mL. Foi utilizado ácido oleico e padrões inorgânicos no preparo das curvas analíticas. O método apresentou boa linearidade (R > 0,99) e desvios padrão menor do que 5%. Os LDs foram de 0,3, 0,1 e 0,07 mg kg-1 para os metais Fe, Cu e Zn, respectivamente. Esses resultados foram melhores do que os obtidos pelo método de referência devido a melhor precisão nas medidas no método proposto. Os resultados dos testes de recuperação (95-102%) indicam a ausência de efeitos de matriz. Os parâmetros obtidos pelo método proposto estão de acordo com os encontrados com o método padrão, o que torna o seu uso viável para a determinação de elementos traço. Para avaliar a exatidão do método foram comparados os resultados de amostras reais com o método de referência e também com o método de decomposição ácida. A aplicação do teste estatístico “t” student, mostrou que não existe diferença significativa entre os resultados obtidos pelos três métodos. Portanto, o uso de microemulsões aliado à técnica F AAS apresentou uma estratégia simples, rápida e prática, além da possibilidade de se utilizar solventes não carcinogênicos. A presença de ácido no meio permite maior disponibilidade e mobilidade dos analitos, evitando a adsorção nas paredes do recipiente além do uso de padrões aquosos na calibração para avaliar a presença de metais no biodiesel. / This work proposes the development of an analytical method for the determination of Fe, Cu and Zn in biodiesel samples by flame atomic absorption spectrometry (F AAS) using microemulsion as sample preparation. The formation of the microemulsion using a less toxic organic solvent instead of the solvent used in the reference method (ABNT NBR 15556), inorganic standards for calibration and the absence of a surfactant was sought. The composition of the microemulsion was investyigated through a three phase diagram and the composition adopted was 1.7 g of biodiesel, 1.1 ml of H2O/HNO3 and completed with propan-1-ol to 10 mL volume. Oleic acid and inorganic standards was used to prepare the calibration curves. The method showed good linearity (R > 0.99) and less than 5% standard deviation. The Limits of Detection obtained were 0.3, 0.1 and 0.07 mg kg-1 for Fe, Cu and Zn, respectively. These results were better than those obtained by the reference method due to lower fluctuation in the measurements in the proposed method. The spike recoveries obtained (95-102%) indicate the absence of matrix effects. The parameters obtained for the proposed method are in agreement with those found for the standard method, which makes feasible its use for the determination of trace elements. In order to evaluate the accuracy of the method the results of real samples were compared with the reference method and also with the method of acid decomposition. The application of the statistic test "t" student showed no significant difference between the results obtained by the three test methods. Therefore, the use of the microemulsions combined with F AAS technique showed a simple, fast and practical strategy, besides the possibility of using non-carcinogenic solvents. The presence of acid in the medium allows greater freedom of analytes, preventing adsorption onto the walls of the container and the use of aqueous standards for evaluating the presence of metals in biodiesel.
|
3 |
Aplicação de técnicas quimiométricas na otimização de métodos usando a espectrometria de emissão óptica com plasma indutivamente acoplado e espectrometria de absorção atômica com chama visando a análise de amostras ambientaisNovaes, Cleber Galvão January 2011 (has links)
174f. / Submitted by Ana Hilda Fonseca (anahilda@ufba.br) on 2013-04-03T14:55:10Z
No. of bitstreams: 1
Tese Cleber.pdf: 3023251 bytes, checksum: 3c19c67227656dc28f623ea371c6e7dd (MD5) / Approved for entry into archive by Ana Hilda Fonseca(anahilda@ufba.br) on 2013-04-23T15:23:58Z (GMT) No. of bitstreams: 1
Tese Cleber.pdf: 3023251 bytes, checksum: 3c19c67227656dc28f623ea371c6e7dd (MD5) / Made available in DSpace on 2013-04-23T15:23:58Z (GMT). No. of bitstreams: 1
Tese Cleber.pdf: 3023251 bytes, checksum: 3c19c67227656dc28f623ea371c6e7dd (MD5)
Previous issue date: 2011 / CAPES / Nesta tese é apresentada a aplicação de técnicas quimiométricas na
otimização de métodos usando a espectrometria de emissão óptica com plasma
indutivamente acoplado (ICP OES) e espectrometria de absorção atômica com
chama (F AAS) visando a análise de amostras ambientais.
No primeiro trabalho, variáveis como potência de radiofrequência, vazão
do gás do plasma, vazão do fluxo de nebulização, vazão do gás auxiliar, vazão da
amostra e concentração de ácido nítrico na amostra foram otimizadas através da
aplicação de planejamento fatorial completo e Box-Behnken. Parâmetros analíticos
como precisão, robustez, sensibilidade e exatidão mostraram-se adequados para
determinação de Al, B, Ba, Ca, Cd, Co, Cr, Cu, Fe, K, Li, Mg, Mn, Mo, Na, Ni, Pb, Si,
Sn, Sr, Ti, Tl, V e Zn em amostras de água subterrânea, água de rio, efluente e solo
usando ICP OES. A estratégia de medição e o tempo total de análise também foram
otimizados. O novo método foi implantado na rotina do laboratório da CETREL e
está proporcionando uma enorme redução no consumo do argônio, em torno de 35
%, gerando uma economia de aproximadamente 320 m3 de argônio anuais, além da
redução nos custos associados a outros acessórios do ICP OES.
No segundo trabalho, três variáveis de pré-concentração do chumbo (pH,
concentração do tampão e vazão da amostra) foram otimizadas empregando
planejamento fatorial completo 23. O método é baseado na sorção de Pb(II) em uma
minicoluna recheada com uma resina de Amberlite XAD-4 funcionalizada com 4-(5´-
bromo-2´-tiazolilazo)orcinol (Br-TAO). O método apresentou limite de quantificação
de 1,7 μg L-1, faixa linear de 1,7-200 μg L-1 e fator de enriquecimento de 36, para
25,0 mL de amostra. A exatidão do método foi verificada pela determinação de
chumbo em material de referência certificado de água doce NIST 1643d. O método
foi aplicado na determinação de chumbo em amostras de água coletadas na cidade
de Jequié-BA usando F AAS. Os teores de chumbo variaram de 4,1 a 5,7 μg L-1.
As ferramentas quimiométricas utilizadas nos dois trabalhos foram muito
eficazes na otimização de variáveis importantes e permitiu um estudo descritivo das
variáveis e suas interações. Os dois métodos apresentaram parâmetros analíticos
adequados para determinação de metais e metalóides em amostras ambientais / Salvador
|
4 |
Desenvolvimento de método para determinação de ferro, cobre e zinco em microemulsão de biodiesel por espectrometria de absorção atômica com chama / Development of method for determination of iron, copper and zinc in biodiesel by flame atomic absorption spectrometry using microemulsion as sample preparationAntunes, Greici Alves January 2016 (has links)
Este trabalho propõe o desenvolvimento de método analítico para a determinação de Fe, Cu e Zn em amostras de biodiesel por espectrometria de absorção atômica com chama (F AAS), utilizando microemulsão como preparo de amostra. Neste trabalho buscou-se, para a formação da microemulsão, o uso de um solvente orgânico menos tóxico do que o solvente usado no método de referência (ABNT NBR 15556), o uso de padrões inorgânicos para a calibração e a ausência de um surfactante. A composição da microemulsão foi estudada através de um diagrama trifásico e a composição adotada foi de 1,7 g de biodiesel, 1,1 mL de H2O/HNO3 e volume completado com propan-1-ol até 10 mL. Foi utilizado ácido oleico e padrões inorgânicos no preparo das curvas analíticas. O método apresentou boa linearidade (R > 0,99) e desvios padrão menor do que 5%. Os LDs foram de 0,3, 0,1 e 0,07 mg kg-1 para os metais Fe, Cu e Zn, respectivamente. Esses resultados foram melhores do que os obtidos pelo método de referência devido a melhor precisão nas medidas no método proposto. Os resultados dos testes de recuperação (95-102%) indicam a ausência de efeitos de matriz. Os parâmetros obtidos pelo método proposto estão de acordo com os encontrados com o método padrão, o que torna o seu uso viável para a determinação de elementos traço. Para avaliar a exatidão do método foram comparados os resultados de amostras reais com o método de referência e também com o método de decomposição ácida. A aplicação do teste estatístico “t” student, mostrou que não existe diferença significativa entre os resultados obtidos pelos três métodos. Portanto, o uso de microemulsões aliado à técnica F AAS apresentou uma estratégia simples, rápida e prática, além da possibilidade de se utilizar solventes não carcinogênicos. A presença de ácido no meio permite maior disponibilidade e mobilidade dos analitos, evitando a adsorção nas paredes do recipiente além do uso de padrões aquosos na calibração para avaliar a presença de metais no biodiesel. / This work proposes the development of an analytical method for the determination of Fe, Cu and Zn in biodiesel samples by flame atomic absorption spectrometry (F AAS) using microemulsion as sample preparation. The formation of the microemulsion using a less toxic organic solvent instead of the solvent used in the reference method (ABNT NBR 15556), inorganic standards for calibration and the absence of a surfactant was sought. The composition of the microemulsion was investyigated through a three phase diagram and the composition adopted was 1.7 g of biodiesel, 1.1 ml of H2O/HNO3 and completed with propan-1-ol to 10 mL volume. Oleic acid and inorganic standards was used to prepare the calibration curves. The method showed good linearity (R > 0.99) and less than 5% standard deviation. The Limits of Detection obtained were 0.3, 0.1 and 0.07 mg kg-1 for Fe, Cu and Zn, respectively. These results were better than those obtained by the reference method due to lower fluctuation in the measurements in the proposed method. The spike recoveries obtained (95-102%) indicate the absence of matrix effects. The parameters obtained for the proposed method are in agreement with those found for the standard method, which makes feasible its use for the determination of trace elements. In order to evaluate the accuracy of the method the results of real samples were compared with the reference method and also with the method of acid decomposition. The application of the statistic test "t" student showed no significant difference between the results obtained by the three test methods. Therefore, the use of the microemulsions combined with F AAS technique showed a simple, fast and practical strategy, besides the possibility of using non-carcinogenic solvents. The presence of acid in the medium allows greater freedom of analytes, preventing adsorption onto the walls of the container and the use of aqueous standards for evaluating the presence of metals in biodiesel.
|
5 |
Avaliação da Contaminação das Areias de Praia do Litoral do Espírito Santo por Elementos-traçoSousa, Rafael Mantovaneli 31 August 2015 (has links)
Submitted by Maykon Nascimento (maykon.albani@hotmail.com) on 2015-12-01T19:02:27Z
No. of bitstreams: 2
license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5)
Avaliacao da contaminacao das areias de praia do litoral do Espírito Santo por elementos traco.pdf: 3522864 bytes, checksum: 1699c03e055b01265d1a32ea527f3bd8 (MD5) / Approved for entry into archive by Morgana Andrade (morgana.andrade@ufes.br) on 2015-12-30T15:17:29Z (GMT) No. of bitstreams: 2
license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5)
Avaliacao da contaminacao das areias de praia do litoral do Espírito Santo por elementos traco.pdf: 3522864 bytes, checksum: 1699c03e055b01265d1a32ea527f3bd8 (MD5) / Made available in DSpace on 2015-12-30T15:17:29Z (GMT). No. of bitstreams: 2
license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5)
Avaliacao da contaminacao das areias de praia do litoral do Espírito Santo por elementos traco.pdf: 3522864 bytes, checksum: 1699c03e055b01265d1a32ea527f3bd8 (MD5)
Previous issue date: 2015 / O Estado do Espírito Santo possui um litoral com grande potencial turístico, graças às belezas naturais de suas praias. Estas são amplamente utilizadas para fins recreativos. Devido ao uso e ocupação da região costeira, este ambiente se encontra sujeito à contaminação de origem química e biológica de suas areias, trazendo riscos à população, que utiliza este espaço como área de lazer, e ao meio ambiente, podendo gerar danos à biota local. O presente estudo tem como objetivo a quantificação de Co, Cr, Cu, Ni, Pb, V, Zn, Fe e Mn em areia de praia, verificando alterações nas concentrações desses elementos traço de acordo com variações sazonais. Foram realizadas quatro campanhas amostrais em quatro praias da região metropolitana do Espírito Santo, sendo duas campanhas em período de estação seca e duas em período estação chuvosa. Para cada região amostral foram coletadas amostras antes e após passagem de frente fria. As amostras foram coletadas na crista da berma e na face da praia. Em cada coleta de amostra foram feitos levantamentos topográficos, para a verificação de alterações nos perfis das praias ao longo das campanhas. Também foi realizado estudo da distribuição granulométrica nas amostras de areia de praia. As amostras de areia foram digeridas utilizando forno com radiação por micro-ondas, empregado 12,0 mL de uma mistura ácida nítrico-fluorídrica (3:1), com um programa de digestão adaptado do método US EPA 3052 (1996). Foram determinados Co, Cr, Cu, Ni, Pb, V e Zn por ICP OES e Fe e Mn por F AAS. A exatidão dos métodos de determinação foram avaliadas através da análise de material de referência certificado (NIST 2702) e do estudo de recuperação (72-123%). Os limites de quantificação encontrados, em mg kg-1, foram: 0,55 para Co, 2,45 para Cr, 0,36 para Cu , 2,08 para Ni, 0,85 para Pb, 3,26 para V, 0,39 para Zn, 0,57 para Fe e 0,23 para Mn. As faixas de concentração dos analitos em mµforam: <LQ – 34,85 para Co, <LQ – 26,99 para Cr, <LQ – 34,36 para Cu, <LQ - 44 75 para Ni, <LQ – 31,92 para Pb, <LQ – 92,03 para V, <LQ – 84,51para Zn, < LQ – 1768 para Fe e <LQ – 4428 para Mn. Os resultados da quantificação dos elementos traço em areia das praias indicaram que a maioria dos analitos está presente nas areias, sendo que alguns em concentrações elevadas. Estudos de correlação de Pearson foram realizados para avaliar o perfil e distribuição dos elementos traço ao longo das campanhas amostrais com as variações topográficas das estações de coleta. Para alguns analitos foi observado que alterações climáticas e sazonais exercem influência em suas concentrações, aumentando ou diminuindo, indicando que o transporte de sedimentos está correlacionado distribuição desses elementos. Comparando os resultados obtidos com de outros trabalhos contidos na literatura, observou-se que as praias do litoral do Espírito Santo apresentaram concentrações próximas para boa parte dos analitos, podendo ser um indicativo de contaminação. / The state of Espírito Santo has a big touristic potential in its coast, thanks to the natural beauty in its beaches. Which are widely used for recreation. Due to the use and the occupation of the coastal region, this environment is subject to chemical and biological contamination of the sand, bringing risks to population that uses this space as recreational area, and to environment, which may harm the local biota. This present study aims to quantify Co, Cr, Ni, Pb, V, Zn, Fe and Mn in beach sand, verifying alterations in the concentration of these trace elements due to seasonal variations. Four sample campaigns have been carried out in four beaches in the metropolitan region of Espírito Santo, where two campaigns were in dry season and two in rainy season. For each season samples were collected before and after the cold front. Samples were collected from the kerb crest and from the beach face. In each sampling, topographic surveys were carried out to verify the changes in beach profiles during the campaign. A study of size distribution in beach sand samples was also carried out. Sand samples were digested with microwave oven, using 12,0 mL of a nitric-fluoride acid mixture (3:1), with a digestion program adapted to the method US EPA 3052 (1996). Co, Cr, Cu, Ni, Pb, V e Zn were determined by ICP OES and Fe and Mn by F AAS. Determination method accuracy was analyzed through certified standard material analysis (NIST 2702) and recuperation study (72-123%). The found quantification limits, in mg kg-1, were: 0,55 for Co, 2,45 for Cr, 0,36 for Cu, 2,08 for Ni, 0,85 for Pb, 3,26 for V, 0,39 for Zn, 0,57 for Fe and 0,23 for Mn. Analytes concentration range in mµ were: <LQ – 34,85 for Co, <LQ – 26,99 for Cr, <LQ – 34,36 for Cu, <LQ – 44,75 for Ni, <LQ – 31,92 for Pb, <LQ – 92,03 for V, <LQ – 84,51 for Zn, <LQ – 1768 for Fe and <LQ – 4428 for Mn. Quantification results of trace elements in beach sand indicates that majority of analytes are present in the sand, some of them in high concentrations. Pearson correlation studies were carried out to evaluate the profile and distribution of trace elements throughout the sampling campaigns with topographic surveys of the collection season. Was observed that, for some analytes, climate and seasonal changes influences in its concentrations, increasing or decreasing, indicating that sediment transportation relates to these elements distribution. Comparing our results with other works in literature, it was observed that the Espírito Santo coast beaches have higher concentrations of most analytes, which could be indicative of contamination.
|
6 |
Desenvolvimento de método para determinação de ferro, cobre e zinco em microemulsão de biodiesel por espectrometria de absorção atômica com chama / Development of method for determination of iron, copper and zinc in biodiesel by flame atomic absorption spectrometry using microemulsion as sample preparationAntunes, Greici Alves January 2016 (has links)
Este trabalho propõe o desenvolvimento de método analítico para a determinação de Fe, Cu e Zn em amostras de biodiesel por espectrometria de absorção atômica com chama (F AAS), utilizando microemulsão como preparo de amostra. Neste trabalho buscou-se, para a formação da microemulsão, o uso de um solvente orgânico menos tóxico do que o solvente usado no método de referência (ABNT NBR 15556), o uso de padrões inorgânicos para a calibração e a ausência de um surfactante. A composição da microemulsão foi estudada através de um diagrama trifásico e a composição adotada foi de 1,7 g de biodiesel, 1,1 mL de H2O/HNO3 e volume completado com propan-1-ol até 10 mL. Foi utilizado ácido oleico e padrões inorgânicos no preparo das curvas analíticas. O método apresentou boa linearidade (R > 0,99) e desvios padrão menor do que 5%. Os LDs foram de 0,3, 0,1 e 0,07 mg kg-1 para os metais Fe, Cu e Zn, respectivamente. Esses resultados foram melhores do que os obtidos pelo método de referência devido a melhor precisão nas medidas no método proposto. Os resultados dos testes de recuperação (95-102%) indicam a ausência de efeitos de matriz. Os parâmetros obtidos pelo método proposto estão de acordo com os encontrados com o método padrão, o que torna o seu uso viável para a determinação de elementos traço. Para avaliar a exatidão do método foram comparados os resultados de amostras reais com o método de referência e também com o método de decomposição ácida. A aplicação do teste estatístico “t” student, mostrou que não existe diferença significativa entre os resultados obtidos pelos três métodos. Portanto, o uso de microemulsões aliado à técnica F AAS apresentou uma estratégia simples, rápida e prática, além da possibilidade de se utilizar solventes não carcinogênicos. A presença de ácido no meio permite maior disponibilidade e mobilidade dos analitos, evitando a adsorção nas paredes do recipiente além do uso de padrões aquosos na calibração para avaliar a presença de metais no biodiesel. / This work proposes the development of an analytical method for the determination of Fe, Cu and Zn in biodiesel samples by flame atomic absorption spectrometry (F AAS) using microemulsion as sample preparation. The formation of the microemulsion using a less toxic organic solvent instead of the solvent used in the reference method (ABNT NBR 15556), inorganic standards for calibration and the absence of a surfactant was sought. The composition of the microemulsion was investyigated through a three phase diagram and the composition adopted was 1.7 g of biodiesel, 1.1 ml of H2O/HNO3 and completed with propan-1-ol to 10 mL volume. Oleic acid and inorganic standards was used to prepare the calibration curves. The method showed good linearity (R > 0.99) and less than 5% standard deviation. The Limits of Detection obtained were 0.3, 0.1 and 0.07 mg kg-1 for Fe, Cu and Zn, respectively. These results were better than those obtained by the reference method due to lower fluctuation in the measurements in the proposed method. The spike recoveries obtained (95-102%) indicate the absence of matrix effects. The parameters obtained for the proposed method are in agreement with those found for the standard method, which makes feasible its use for the determination of trace elements. In order to evaluate the accuracy of the method the results of real samples were compared with the reference method and also with the method of acid decomposition. The application of the statistic test "t" student showed no significant difference between the results obtained by the three test methods. Therefore, the use of the microemulsions combined with F AAS technique showed a simple, fast and practical strategy, besides the possibility of using non-carcinogenic solvents. The presence of acid in the medium allows greater freedom of analytes, preventing adsorption onto the walls of the container and the use of aqueous standards for evaluating the presence of metals in biodiesel.
|
7 |
Zhodnocení vlivu aplikace vytěžených sedimentů z vodního díla Luhačovice na obsah rizikových prvků v orné půdě / Assessment the impact of the application of excavated sediments from the dam Luhačovice on the content of risk elements in arable soilKratěnová, Pavla January 2013 (has links)
This diploma thesis focuses on an issue concerning an excavated sediment application on an arable soil and its impact on the soil quality based on a particular case of a deposition of the sediment from the dam Luhačovice on an adjacent agricultural area. The theoretical part of this thesis is focused on a soil and sediment characteristics and functions, contained risk elements, sampling methods, determination possibilities of particular risk elements and a description of conditions which emerged from a need for the deposition of sediment obtained during scavenging of the dam Luhačovice. In the experimental part was described the process of sampling, samples processing and determining of concentration values for chosen risk elements (Cd, Cu, Hg, Ni, Pb) using flame or electrothermal atomic absorption spectrometry methods. This part also contains an evaluation of obtained results and a validation of an approval for the sediment deposition.
|
8 |
Kontaminace vybraných částí města Brna těžkými kovy / Heavy metals contamination of selected Brno city localitiesDebnárová, Andrea January 2010 (has links)
This thesis is focused on the degree of soil contamination with heavy metals in urban area of Brno. Samples were collected in three periods from October 2009 to March 2010, to represent different seasons and their impact on the concentration of heavy metals in examined soil. Ten locations was chosen, each with different level of concentration, starting with busy traffic area where the concentration of means was high continuing to areas located around habitation or parks. As result four elements were determined in every sample: Cu, Cd, Hg and Pb. Presence of copper and lead were detected by flame atomic absortion spectroscopy (F-AAS) and, cadmium by the help of electrothermal atomic absortion spectroscopy (ET-AAS). For the determination of mercury was used advanced mercury analyzer (AMA).
|
9 |
Kontaminace vybraných lokalit Ostravy těžkými kovy / The heavy metal contamination of selected sites in OstravaMihočová, Silvie January 2011 (has links)
This thesis is focused on the assessment of contamination of non-agricultural soils of selected locations in Ostrava of hazardous metals. Selection of locations was based on the stationary pollution source REZZO1. Total 36 collected samples from 12 locations in three times periods between July 2010 and March 2011 that each collection represented a different time period for characteristic emissions conditions. The risk of metals mercury, cadmium, lead, copper and chromium were determined by atomic absorption spectrometry (F AAS, ET AAS, AMA 254).The influence of the distance of locations from stationary sources of REZZO1 on the extent of soil contamination by selected metals was confirmed.
|
10 |
Stanovení těžkých kovů v odpadních energetických materiálech s využitím sekvenční extrakce / Determination of heavy metals in waste energetic materials with using sequential extractionKořínková, Alena January 2011 (has links)
Tato diplomová práce pojednává o stanovení vybraných kovů v energetických odpadech, jako je úletový popílek, škvára, struska, ložový popel, produkt odsíření apod., které pocházejí ze čtyř moravských tepláren. Extrakce kovů z energetických materiálů byla provedena Tessierovou extrakcí. Za tímto účelem byla použita extrakční činidla chlorid hořečnatý (MgCl2), octan sodný (CH3COONa), hydroxylamin hydrochlorid v kyselině octové (NH2OH.HCl v CH3COOH), peroxid vodíku v kyselině dusičné (H2O2 v HNO3) a kyselina fluorovodíková (HF). Extrakce probíhala při teplotách 25°C a 40°C. Ve všech frakcích byly stanoveny olovo, měď a kadmium s využitím atomové absorpční spektrometrie (F AAS, ET AAS) a rtuť metodou AMA 254.
|
Page generated in 0.0372 seconds