• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 862
  • 15
  • 9
  • 8
  • 8
  • 8
  • 6
  • 2
  • 2
  • 2
  • 2
  • 1
  • Tagged with
  • 888
  • 550
  • 358
  • 160
  • 158
  • 157
  • 155
  • 125
  • 122
  • 114
  • 111
  • 106
  • 100
  • 90
  • 87
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
501

Ultra-sonometria óssea para determinação do risco de fratura do fêmur / Bone ultra-sonometry for the assesment of the fêmur fracture risk

Fachine, Luiz Tadeu de Moura 19 December 2006 (has links)
A osteoporose é uma doença que afeta o tecido ósseo diminuindo sua resistência, que é determinada pela sua densidade, arquitetura e velocidade de remodelamento. O método padrão atualmente utilizado para seu diagnóstico e monitoramento é a densitometria óssea, que utiliza radiação ionizante, e que, por ser caro, é inacessível à maioria da população de baixa renda. Tem, ainda, o inconveniente de não avaliar adequadamente a massa óssea e nem a sua resistência. Vários estudos têm sido publicados discutindo o uso de técnicas complementares ou alternativas para tornar essa avaliação mais confiável. Uma dessas técnicas é a ultra-sonometria óssea do calcâneo, que se baseia na análise da propagação do ultra-som através do osso traduzindo informações de sua qualidade e, com isso, predizendo o risco de fratura, principalmente do colo do fêmur. Esse método não utiliza radiação ionizante, é de fácil aplicação e de baixo custo. Atualmente é utilizado para rastreamento populacional de indivíduos candidatos à densitometria óssea. Como os resultados desse método têm uma melhor correlação com o indivíduo idoso e na avaliação do colo do fêmur, propôs-se a sua utilização para avaliar pacientes de baixa renda cadastrados em serviços públicos de saúde, a maioria com doenças concomitantes, rastreando-os para que sejam submetidos a programas de prevenção de fraturas do fêmur, conseqüência de maior morbidade e mortalidade da osteoporose. Como método, um grupo de 757 mulheres idosas foi submetido à avaliação pela ultra-sonometria óssea do calcâneo. Destas, 71% foram considerados com risco aumentado de fratura (24% com osteoporose e 47% com osteopenia, de acordo com os critérios da OMS para a densitometria óssea) e 29% normais, dados importantes pelo elevado número de indivíduos em risco. Outros parâmetros também foram analisados em função de um questionário respondido pelas examinadas, que mostrou, entre outras informações, a concomitância de moléstias. / Osteoporosis is a disease which affects the bone tissue reducing its resistance that is determined by its density, architecture and speed of remodeling. Currently, the pattern method used for its diagnosis and monitoring is the bone densitometry which makes use of ionizing radiation and because of its high costs, it is not available to the majority of the low-income population. It also has the inconvenience of neither assessing adequately the bone mass nor its resistance. Several studies have been published discussing the use of complementary or alternative techniques to make this evaluation more reliable. One of these techniques is the bone ultra-sonometry of the calcaneus which is based on the analysis of the ultrasound propagation thought the bone translating information about its quality and therefore predicting mainly the fracture risk in the femoral collum this method do not use ionizing radiation, it is easy to apply and has low costs. Nowadays, it is used for populational screening of individuals who are candidates for bone densitometry. As its results have a better correlation with this method in the old individual and in the assessment of the femoral neck, its utilization its proposed to evaluate low-income patients registered at the public health, most of them suffering from concomitant diseases, screening them in the order to be submitted to preventive programs of femoral fractures, the consequence of increased morbity and mortality related to osteoporosis. As a method, a group of 757 old women was submitted to the evaluation by the bone ultra-sonometry of the calcaneus. 71% or the women were considered with increased fracture risk (24% with osteoporosis and 47% with osteopenia according to the WHO criteria for densitometry) and 29% were normal, important data because of the high number of individuals at risk. Other parameters were also analyzed in terms of a questionnaire answered by the evaluated women showing the concomitance of diseases besides other information. The obtained data are not coincident with those from the literature that observes old individuals who were randomly chosen within the population in general. Such a fact is related to the criterion used for the choice of the studied universe constituted by patients and not simply by individuals who were already registered at the health treatment service. For these reasons, it was concluded that the method in question is valuable to screen low-income old women with the facture risk increased by the reduction of the bone resistance and conduct them to preventive programs of femoral fractures.
502

Determinação da tenacidade à fratura do aço aeronáutico 300M, submetido a diferentes parâmetros de tratamentos térmicos e criogenia, utilizando técnica de corpo cilíndrico com entalhe / Fracture toughness determination for 300M aeronautic steel, with different heat treatment parameters and deep cryogenic, using the circumferentially round notched specimens technique

Schuller, Daniel 23 March 2016 (has links)
Foi realizado estudo sobre a influência da variação de alguns parâmetros do tratamento térmico de têmpera e revenimento, bem como aplicação de criogenia, na tenacidade a fratura do aço aeronáutico 300M, com a utilização da técnica de corpo cilíndrico com entalhe. Primeiramente, realizou-se a construção da curva de transição dúctil frágil, através de ensaio Charpy, para amostras submetidas a três tratamentos térmicos, 1 - Têmpera seguida de Revenimento, 2 - Têmpera seguida de criogenia e revenimento. Não foi observada influência significativa da aplicação da criogenia (tratamento de numero 2) na curva de transição dúctil-frágil em comparação com o tratamento térmico número 1. Em um segundo momento, com o auxílio da técnica de ensaio de corpo cilíndrico com entalhe, realizou-se a medição da tenacidade à fratura das amostras do aço 300M submetido a quatro diferentes tratamento térmicos, Q, V, C e D. Os tratamentos variavam entre si principalmente pela temperatura de austenitização. Os valores de dureza para as amostras submetidas a criogenia (V e D) foram maiores que as dos tratamentos sem criogenia (Q e C), e também apresentaram tenacidade à fratura menor. Com relação à temperatura de austenitização, observou-se que os tratamentos C e D, austenitizados a 980°C, propiciaram a completa dissolução de precipitados primários da matriz, elevando a tenacidade à fratura com relação aos tratamentos realizados na faixa de 870°C, Q e V, superando também os efeitos negativos para a tenacidade à fratura devido ao aumento no tamanho de grão. / This work studies the influence of the variation for some parameters on quenching and tempering heat treatment, and also deep cryogenic application, on aeronautic steel 300M fracture toughness. First, the ductile-brittle curve was constructed, by Charpy test, for samples submitted for three heat treatments, 1 Quenching and Tempering, 2 Quenching, deep cryogenic and tempering. No significant influence of deep cryogenic treatment addition (heat treatment 2) on ductile-brittle curve was observed in comparison with heat treatment 1. After that, the fracture toughness for 300M steel, submitted for heat treatments Q, V, C e D, was measured using circumferentially notched specimens technique. The main difference among these heat treatments is about austenitizing temperature. For heat treatments with deep cryogenic treatment (V and D), the hardness values were bigger than the ones without this and, analyzing fracture toughness, it was lower than the treatments without cryogenic treatment. Regarding austenitizing temperature, all heat treatments with higher austenitizing temperature at 980°C (C and D), allows complete dissolution of carbides and prior precipitates particles. Its effect was observed that this characteristic increase the fracture toughness when it is compared with others heat treatments with lower austenitizing temperature at 870°C (Q and V). This improvement is enough to overcome the grain size grown negative effects for fracture toughness.
503

Estudo biomecânico comparativo de sistemas de fixação de 2,0-mm locking e convencionais em fraturas de ângulo em mandíbulas de cordeiro sob esforços em três eixos no espaço / Comparative biomechanical study of locking and conventional 2,0-mm fixation systems on angle fractures in sheep\'s mandibles under stresses on three axes in space

Saavedra, Milton de Siqueira Ferreira Anzaloni 23 February 2017 (has links)
O objetivo deste trabalho foi avaliar comparativamente a rigidez vertical, horizontal e de resistência à ruptura, com liberdade de movimentos em três eixos no espaço, de mandíbulas fixadas com sistemas 2,0-mm locking e convencionais com uma ou duas placas, em fraturas unilaterais no ângulo mandibular. Vinte mandíbulas de cordeiro, submetidas a osteotomia reproduzindo fraturas, foram divididas em três grupos: F1PC - placa convencional em linha oblíqua; F2PC - duas placas convencionais de modo monoplanar; FL - placa de sistema locking 2,0mm em linha oblíqua. Foi utilizada máquina de ensaio universal, onde foi acoplado suporte metálico com rodas para as mandíbulas. O sistema foi analisado em três diferentes momentos: pré-osteotomia com mandíbulas hígidas e pós-osteotomia/fixação e resistência à ruptura. Os valores de rigidez foram submetidos a análise de variância (p<0,005). Os valores de rigidez vertical (p< 0,0001), horizontal (p= 0,0005) e resistência a ruptura (p= 0,0001) entre pré e pósosteotomia/ fixação apresentaram uma diminuição significante. Na comparação entre os grupos, houve diferença significante para a rigidez vertical (p= 0,009) e o grupo F2PC apresentou maior rigidez. Na comparação entre os grupos, não houve diferença significante para a rigidez horizontal e para resistência a ruptura. Foi concluído que para rigidez vertical, horizontal e resistência a ruptura os valores de pós-osteotomia/fixação foram significantemente menores, o sistema de fixação com duas placas convencionais mostrou maior resistência quanto à rigidez vertical que os demais sistemas e não houve diferença estatisticamente significante na comparação entre os grupos quanto a rigidez horizontal e resistência a ruptura. / The objective of this work was to evaluate the vertical, horizontal and tensile rigidity with freedom of movement in three axes in space, of mandibles fixed with 2.0-mm locking and conventional systems with one or two plates, in unilateral fractures in the Angle of the mandible. Twenty mandibles of lamb, submitted to osteotomy and reproducing fractures, were divided into three groups: F1PC - conventional oblique line; F2PC - two conventional single-mode boards; FL - 2.0mm locking system plate in oblique line. A universal test machine was used, where metal support was coupled with wheels for the jaws. The system was analyzed in three different moments: pre-osteotomy with healthy mandibles and post-osteotomy / fixation and resistance to rupture. The stiffness values were submitted to analysis of variance (p <0.005). The values of vertical rigidity (p <0.0001), horizontal (p = 0.0005) and resistance to rupture (p = 0.0001) between pre and post osteotomy / fixation showed a significant decrease. In the comparison between the groups, there was a significant difference for vertical stiffness (p = 0.009) and the F2PC group presented greater stiffness. In the comparison between the groups, there was no significant difference for horizontal rigidity and for resistance to rupture. It was concluded that for post-osteotomy / fixation values were significantly lower for vertical, horizontal and tensile rigidity, the fixation system with two conventional plates showed greater resistance to vertical rigidity than the other systems and there was no statistically significant difference in comparison between the groups for horizontal rigidity and resistance to rupture.
504

Estudo do comportamento mecânico em baixas temperaturas do Inconel 625 encruado / Studying the mechanical behavior of Inconel 625 cold drawn in low temperatures

Clovis de Oliveira Junior 07 December 2018 (has links)
As recentes descobertas de reservas de petróleo no pré-sal, representam uma grande oportunidade e desafio para a Petrobrás e demais indústrias de exploração e extração do petróleo. As exigências quanto aos materiais mais resistentes à corrosão e que conciliam boa resistência mecânica são cada vez maiores, devido aos constantes esforços dinâmicos que os equipamentos estarão sujeitos, pois os componentes estruturais serão submetidos à grande lâmina de água, ocorrência que as companhias exploradoras terão que superar. A otimização de materiais e equipamentos que podem melhorar a performance nas explorações do pré-sal tem sido a grande busca do setor nos últimos anos, muitos deles precisam ser testados e atestados quanto sua resistência à propagação de trincas, uma vez que, serão submetidos a oscilações devido as movimentações das marés e as condições de alta severidade a que serão expostos. Para suportar as condições de exposições com H2S, resistência a corrosão por pitting e resistência mecânica, porcas e parafusos têm sido fabricados com o Inconel 625, essas peças são estruturais e de extrema importância para a prospecção do petróleo. Após todas as etapas de fabricação, conformação, tratamento térmico e laminação a frio, o material foi caracterizado, realizou-se ensaio de metalografia que apresentou tamanhos de grão 7 e 8 conforme norma ASTM E112. Uma das premissas para a realização desse trabalho está nas condições que o material será exposto em situações acidentais, conforme informações da própria Petrobrás, em caso de vazamentos, os do tipo estruturais podem ser submetidos a temperaturas criogênicas de -100°C, -120°C e até -190°C devido ao vazamento de gases. Assim, o material foi caracterizado em temperaturas criogênicas através dos ensaios de tração, impacto e de CTOD. No ensaio de tração foi observado para as diferentes temperaturas criogênicas que apesar do aumento na resistência do material, da ordem de 787 MPa, o Inconel 625 manteve um alongamento acima de 40%. Nos resultados de Impacto a tenacidade se manteve acima de 200 J e não foi notada a curva de transição dúctil-frágil, mesmo para temperaturas tão baixas. No ensaio de CTOD utilizou-se corpos de prova de flexão (SENB) no ensaio de tenacidade à fratura, de acordo com a norma ASTM E1290.A componente plástica da abertura da boca do entalhe na temperatura de -190°C, pior caso, se manteve em 1,52 mm em média. Mediante a todos os resultados obtidos, pode-se afirmar que o aumento da resistência do Inconel 625 pelo processo de encruamento, não impossibilita sua aplicação para temperaturas criogênicas, mantendo sua capacidade de se deformar apreciavelmente antes de se romper. / Recently oil and gas discoveries in the Pre-Salt layer represent a huge exploration potential in Brazil, however, the technological challenges for the exploitation of these mineral resources are immense and therefore have motivated the development of studies looking for efficient methods and materials for their productions. The requirements about materials more corrosion resistance and mechanical resistance have been more frequently, as a result of high deep layer to explore the petroleum. The materials and equipment optimization to improve the performance in the pre-salt exploration have been the big search for oil and gas companies in the last years, but this materials must be testing in the crack propagation, because, this materials must resistance by oscillations, as consequence of ocean movements and others difficult situations that the materials must be support. To support H2S conditions, corrosion resistance by pitting corrosion and high mechanical resistance, bolts and nuts have been manufactured with Inconel 625, these products are structural and they are extreme importance to petroleum exploration. After all manufacturing operations, hot worked heat treatment and cold worked, the material was studied, and it was realized micrographic testing that result in grain size 7 and 8, in accordance ASTM E112 standard. One of premise to realized this paper are in the conditions that the material will be supported in accident situations, in agreement of Petrobras information, in the gases scape accidents, the structure materials can be exposed in cryogenically temperatures of -100°C, -120°C until -190°C. Therefore, the material was studied in cryogenically temperatures throw tensile testing, impact testing and CTOD. In the tensile testing was noted to different kind of cryogenically temperatures, same with more mechanical resistance, 787 MPa yield strength, the Inconel 625 has kept the 40% elongation. In the impact testing the notch toughness as kept above 200 J and it was not seen the transition ductile-Brittle in the low temperatures. In the CTOD testing was used bending test specimens (SENB) in the fracture toughness test for the Inconel 625, in agreement with the ASTM E1290 standard. The specimens was testing in tension and CTOD test in low temperatures: -100°C, -120°C and -190°C.The Clip gage displacement was recorded in the -190°C temperature with 1,52 mm average, this is the worse situation. Analyzing all the results, can be considered that the growth mechanical resistance of Inconel 625 by cold worked process, allow your application with cryogenically situations and the material has kept your ability to be well deformed before the crack.
505

A INFLUÊNCIA DOS MECANISMOS DE DEFORMAÇÃO PLÁSTICA NA MEDIDA DE TENACIDADE PELA TÉCNICA DE MICROINDENTAÇÃO EM VIDROS

Justo, Virgínia Moreira 29 April 2014 (has links)
Made available in DSpace on 2017-07-21T19:26:10Z (GMT). No. of bitstreams: 1 Virginia Moreira Justo.pdf: 3484061 bytes, checksum: 27375d0ff0fb33633f5e7faf4346583f (MD5) Previous issue date: 2014-04-29 / Fundação Araucária de Apoio ao Desenvolvimento Científico e Tecnológico do Paraná / This study investigated the effects of Poisson’s ratio on fracture toughness measured by microindentation using the models of Anstis et al. and Niihara et al. Experiments were performed in different oxide glasses with Poisson’s ratio ranging from 0,15 to 0,28. The glass transition temperatures of the glasses were measured by differential scanning calorimetry.. The amorphous state of the glasses were confirmed by X-ray diffraction. Hardness and elastic modulus were measured using instrumented indentation. The fracture toughness values, KIC, were obtained using the double torsion and four point bending techniques. The relation between the applied load and the crack radial length was obtained using the Vickers microindentation technique. It was noted the existence of two systems. For Poisson’s ratio smaller than 0,20, the main deformation mechanism is densification and the calibration coefficients are smaller than those reported in the literature. On the other hand, when the Poisson’s ratio are higher than 0,20, the main deformation mechanism is by shear and the calibration coefficients are higher than those reported in literature. / Este trabalho investigou o efeito do coeficiente de Poisson na medida da tenacidade à fratura pela técnica de microindentação utilizando os modelos de Anstis et al. e de Niihara et al. em vidros. Foram utilizados vidros óxidos de diferentes composições e com o coeficiente de Poisson variando de 0,15 a 0,28. Análises térmicas foram realizadas para a medida da temperatura de transição vítrea das amostras. Por meio da técnica de difração de raios X, comprovou-se o estado amorfo dos materiais indicando a estrutura vítrea. A dureza e módulo de elasticidade dos vidros foram medidos por meio de indentação instrumentada. Os valores de tenacidade à fratura, KIC, foram obtidos utilizando as técnicas de torção dupla e flexão de quatro pontos. A relação entre a carga aplicada e o comprimento da trinca radial foi obtida utilizando a técnica de microindentação Vickers. Observou-se a existência de dois regimes. Para valores de coeficiente de Poisson menores que 0,20, o principal mecanismo de deformação é a densificação e os coeficientes de calibração são menores. No outro, onde os valores de coeficiente de Poisson são maiores do que 0,20, o mecanismo principal de deformação é o de cisalhamento e os coeficientes de calibração são maiores do que reportado na literatura.
506

Fratura de fêmur: aspectos clínicos e cirúrgicos de idosos atendidos em um hospital militar do Distrito Federal entre 2006 e 2017

Lisbôa, Vanderlúcia Ribeiro de Souza 04 July 2018 (has links)
Submitted by Sara Ribeiro (sara.ribeiro@ucb.br) on 2018-08-09T17:07:15Z No. of bitstreams: 1 VanderluciaRibeirodeSouzaLisboaDissertacao2018.pdf: 2362855 bytes, checksum: af2c02f95e01bb05dc2a3cd7e32c01c5 (MD5) / Approved for entry into archive by Sara Ribeiro (sara.ribeiro@ucb.br) on 2018-08-09T17:07:21Z (GMT) No. of bitstreams: 1 VanderluciaRibeirodeSouzaLisboaDissertacao2018.pdf: 2362855 bytes, checksum: af2c02f95e01bb05dc2a3cd7e32c01c5 (MD5) / Made available in DSpace on 2018-08-09T17:07:21Z (GMT). No. of bitstreams: 1 VanderluciaRibeirodeSouzaLisboaDissertacao2018.pdf: 2362855 bytes, checksum: af2c02f95e01bb05dc2a3cd7e32c01c5 (MD5) Previous issue date: 2018-07-04 / Introduction: In recent years, there have been a number of changes in life cycles that have resulted in increased life expectancy, with a decline in mortality that has benefited people from all demographic regions. Parallel to the demographic changes, there are changes in morbidity and mortality patterns characterized by the increase of chronic-degenerative diseases and factors that may result in dependence and lower quality of life, especially the fall of the height and femur fracture. Objective: To describe the clinical and surgical aspects of the elderly with femoral fracture treated at a military hospital of the Federal District between 2006 and 2017. Method: The design of this research is an epidemiological investigation of the descriptive retrospective type of case series. The sample consisted of records of the elderly with femur fracture due to falls of the same height, attended at the hospital between 2006 and 2017. Data collection was done at the institution, using the records on clinical and surgical data available in the medical records. Patients, from their hospitalization to the end, using a data collection instrument developed by the author. Data analysis was performed using the Statistical Package for the Social Sciences (SPSS) software version 22.0, with a significance level of 5% (p <0.05). The descriptive statistics were performed using the distribution measures (mean, standard deviation - SD, absolute and relative frequency), considering the variables of interest in order to characterize the sample. For the inferential analyzes of the clinical and surgical data, non-parametric chi-square. Results: the sample consisted of 31 medical records of the elderly with mean age of 79 old. The number of fractures was higher in the elderly with 80 years of age or older (51.6%). It was observed that the fractures prevailed in women (80.6%), who declare themselves to be white (71%) from the Southeast region, living in the Federal District, urban region and married. There was a predominance of transtrochanteric fractures of the left femur treated with osteosynthesis and SAH as comorbidities and use of antihypertensive as a medication for continuous use. Patients with ASA II were more frequent. As to the number of intercurrences, the majority of the elderly had 5 to 9 intercurrences. The variables that had a positive correlation with the hospitalization time were DM and ASA. Conclusion: It was verified that the characterization of the patients analyzed follows a pattern of clinical diagnosis and age distribution with predominance of fractures in elderly, female and white declared elderly. / Introdução: Nos últimos anos, ocorreram várias mudanças nos ciclos da vida, que resultaram no aumento da expectativa de vida, com queda da mortalidade, que beneficiou pessoas de todas as regiões demográficas. Paralelamente às mudanças demográficas, ocorrem alterações nos padrões de morbimortalidade, caracterizados pelo aumento de doenças crônico-degenerativas e de fatores, que podem resultar em dependência e menor qualidade de vida, destacando-se a queda da própria altura e fratura de fêmur. Objetivo: Descrever os aspectos clínicos e cirúrgicos dos idosos com fratura de fêmur atendidos em um hospital militar do Distrito Federal entre 2006 e 2017. Método: O desenho desta pesquisa é de uma investigação epidemiológica do tipo descritiva retrospectiva de série de casos. A amostra foi constituída por prontuários de idosos com fratura de fêmur por quedas da própria altura, atendidos no hospital entre 2006 e 2017. A coleta de dados foi realizada junto à instituição, utilizando os registros sobre dados clínicos e cirúrgicos disponíveis nos prontuários dos pacientes, desde a sua internação até o desfecho, empregando um instrumento de coleta de dados elaborado pela autora. A análise dos dados foi realizada por meio do software Statistical Package for the Social Sciences® (SPSS) versão 22.0, adotando-se o nível de significância de 5% (p < 0,05). A estatística descritiva foi realizada usando as medidas de distribuição (média, desvio padrão, frequência absoluta e relativa), considerando as variáveis de interesse, a fim de caracterizar a amostra. Para as análises inferenciais dos dados clínicos e cirúrgicos, foram rodados testes não paramétricos qui-quadrado. Resultados: A amostra foi constituída por 31 prontuários de idosos com média de idade de 79 anos. O número de fraturas foi maior em idosos com 80 anos de idade ou mais (51,6%). Observou-se que as fraturas prevaleceram em mulheres (80,6%), nos que se declararam brancos (71%), provenientes da Região Sudeste, residentes no Distrito Federal, em região urbana, e casados. Houve predomínio das fraturas transtrocantéricas de fêmur esquerdo, tratadas com osteossíntese, e a hipertensão arterial sistêmica como comorbidades e uso de anti-hipertensivo como medicação de uso contínuo. Pacientes com ASA II foram mais frequentes. Quanto ao número de intercorrências, a maioria dos idosos teve 5 a 9 intercorrências. As variáveis que tiveram correlação positiva com o tempo de internação foram o Diabetes Mellitus e a classificação ASA. Conclusão: Verificou-se que a caracterização dos pacientes analisados segue um padrão de diagnóstico clínico e distribuição etária com predominância de fraturas em idosos longevos, do sexo feminino e declarados brancos.
507

Análise de juntas soldadas por fricção utilizando pinos consumíveis com adição de níquel em chapas de aço com manganês

Buzzatti, Jonas Trento January 2017 (has links)
Os processos de união por soldagem entre peças e componentes metálicos são indispensáveis para nossa realidade tecnológica. O processo de soldagem por fricção com pino consumível conhecido como FHPP (Friction Hydro Pillar Processing) é um processo desenvolvido recentemente que ocorre no estado sólido através da fricção entre dois materiais e, com isso, reúne algumas vantagens sobre os processos convencionais de soldagem por fusão. Esta técnica apresenta grande potencial de aplicação na indústria de óleo e gás visando reparos de trincas e descontinuidades em equipamentos e estruturas de aços em geral. Apesar do grande potencial desta técnica, o estudo sobre a sua aplicação para produzir juntas com materiais dissimilares ainda é escasso se comparado com outras técnicas de soldagem. Desta forma, este trabalho tem como objetivo o desenvolvimento e a análise de juntas soldadas utilizando pinos com adição de níquel em chapas de aço com manganês, visando determinar a combinação entre material de pino e parâmetros de soldagem que forneça a junta com melhores características mecânicas e metalúrgicas. Os parâmetros de soldagem que variaram foram: velocidade de rotação e a força axial. Os materiais utilizados nos conjuntos soldados foram chapas de aço ao manganês, classificadas comercialmente como ASTM A516 grau 70, e barras de aço baixo carbono com adição de 3, 6 e 9% de níquel. A análise realizada sobre as juntas abrangeu a caracterização da microestrutura e das propriedades de dureza das regiões específicas da solda além dos ensaios mecânicos de dobramento, tração com micro-amostras e de tenacidade à fratura através do parâmetro CTOD. Todas as soldas tiveram bom preenchimento, porém alguns materiais de pino não proporcionaram boa ductilidade durante o dobramento. As falhas ocorridas durante o dobramento juntamente com os estudos da tenacidade à fratura na zona de ligação mostraram que o acúmulo de inclusões nesta região representa degradação das propriedades mecânicas localmente. Os ensaios de tração com micro-amostras indicam aumento da resistência mecânica na região do material depositado do pino e os valores de CTOD no material termomecânicamente afetado são significativamente maiores do que na zona de ligação, porém não alcançam os valores obtidos nos materiais como não processados. / The processes of union by welding between parts and metallic components are indispensable for our technological reality. The Friction Hydro Pillar Processing (FHPP) process is a newly developed process that occurs in the solid state through friction between two materials and thus has some advantages over conventional fusion welding processes. This technique presents great potential of application in the oil and gas industry aiming repairs of cracks and discontinuities in equipment and steel structures in general. Despite the great potential of this technique, the study of its application to produce joints with dissimilar materials is still scarce compared to other welding techniques. The aim of this work is the development and analysis of welded joints using rod with nickel addition in steel sheets with manganese, in order to determine the combination of rod material and welding parameters that provides the joint with better mechanical and metallurgical characteristics. The welding parameters that varied were: speed of rotation and axial force. The materials used in the welded assemblies were manganese steel plates, commercially classified as ASTM A516 grade 70, and low carbon steel with addition of 3, 6 and 9% nickel. The analysis of the joints included the characterization of the microstructure and the hardness properties of the specific regions of the weld in addition to the bend test, micro-tensile test and fracture toughness through the parameter CTOD. All welds were well filled, however, some rod materials did not provide good ductility during bend test. The failures during folding together with the fracture toughness studies in the bonding zone showed that the accumulation of inclusions in this region represents degradation of the mechanical properties locally. The micro-tensile test indicate increased mechanical strength in the region of the deposited material of the rod and the values of CTOD in the thermomechanically affected material are significantly higher than in the bonding zone, but do not reach the values obtained in the unprocessed material.
508

Efeitos de heterogeneidades mecânicas sobre forças motrizes de trinca em juntas soldadas: determinação experimental de tenacidade e extensão de metodologias de avaliação de criticidade de defeitos. / Effects of weld strength mismatch on crack tip driving forces of welded joints: experimental evaluation of fracture toughness and extension of methodologies for integrity assessment.

Donato, Gustavo Henrique Bolognesi 23 October 2008 (has links)
Este trabalho apresenta uma avaliação dos efeitos de juntas soldadas dissimilares sobre forças motrizes de trinca e o desenvolvimento de procedimentos adaptados baseados em critérios mecânicos e micromecânicos para avaliação de defeitos em juntas soldadas incorporando efeitos de dissimilaridades mecânicas. A motivação central reside na forte expansão da indústria nacional de petróleo e a crescente demanda por aumento de produtividade aliado ao aumento na segurança operacional de sistemas dutoviários e estruturas correlatas. Para que tal intento seja atingido, é inicialmente apresentada uma descrição detalhada dos parâmetros de interesse da mecânica da fratura, fundamentos da metalurgia da soldagem e efeitos microestruturais e mecânicos oriundos da presença de soldas dissimilares. São então descritos os principais métodos experimentais de determinação de tenacidade à fratura, detalhados os procedimentos correntes de avaliação de integridade por meio de diagramas FAD e é estudada a teoria da tensão de Weibull. Tais estudos configuram o arcabouço conceitual necessário para o desenvolvimento de uma extensa variedade de ensaios experimentais em juntas soldadas e proposição de correções aos procedimentos correntes de determinação experimental de tenacidade, refinamentos na determinação de cargas limite e o desenvolvimento de um modelo de transferabilidade de tenacidades baseado em tensão de Weibull aplicável a juntas soldadas. Por fim, todas as contribuições são compiladas e incorporadas em um procedimento adaptado do tipo FAD especificamente adaptado à avaliação de estruturas soldadas constituídas de materiais dissimilares. Os resultados experimentais revelam forte e deletéria influência das juntas soldadas na tenacidade e capacidade de carga de estruturas. Por outro lado, o extenso compêndio de fatores eta e rotacionais plásticos rp desenvolvido permite a determinação experimental acurada de tenacidade à fratura para espécimes SE(B) homogêneos e bimateriais. Adicionalmente, a metodologia proposta de determinação de cargas limite incorpora o encruamento dos respectivos materiais e o modelo de transferabilidade baseado em tensão de Weibull permite a estimação acurada da tenacidade de componentes soldados dissimilares a partir dos dados do metal de base e poucas calibrações experimentais. Resultados de uma aplicação exploratória real indicam elevado grau de precisão e corroboram a validade das propostas apresentadas. Assim, os desenvolvimentos do presente trabalho mostram-se como potenciais ferramentas de projeto e avaliação de integridade estrutural. / This work presents an evaluation of weld strength mismatch effects on crack driving forces and proposes an extension of defect assessment procedures for welded structures to include effects of weld strength mismatch. The main motivation is based on the strong expansion of Brazilian petroleum industry and the increasing demand for productivity, safety and reliability of pipelines and correlated structures. In this context, it is initially presented a detailed description of fracture mechanics parameters, welding metallurgy fundamentals and mechanic and microestructural effects due to mismatched welds. Next, the main procedures for experimental evaluation of fracture toughness are addressed followed by a discussion on current integrity assessment standards based on FAD and the Weibull stress methodology. These studies provide the necessary background to conduct a wide variety of experimental tests in welded joints and the proposal of corrections for experimental fracture toughness evaluation in welded joints, corrections for limit load estimation schemes in mismatched structures and a new toughness scaling model based on Weibull stress applicable to welded mismatched joints. Finally, the resulting framework is incorporated into a modified FAD-based procedure specifically designed for integrity assessment of welded mismatched structures. The experimental results reveal strong deleterious effects of mismatched welds on loading capacity and fracture toughness of the analyzed specimens. However, the extensive body of calibrated eta and plastic rotational rp factors allows accurate experimental determination of fracture toughness for homogeneous and bimaterial SE(B) specimens. Additionally, the limit load estimation scheme proposed incorporates the materials hardening capacity while the Weibull-based toughness scaling model incorporating mismatch effects allows accurate estimation of the weldment toughness from base metal data and a simple experimental calibration. Results from an exploratory application indicate a high degree of accuracy and confirm the validity of the proposed methodology as a potential tool for design and integrity assessments of cracked weldments.
509

Avaliação do comportamento de seladores endodônticos e a influência destes materiais sobre o diagnóstico de fraturas radiculares por meio de tomografia computadorizada por feixe cônico / Endodontic fillings behavior evaluation and their influence in root fracture diagnosis by means of cone beam computed tomography

Salineiro, Fernanda Cristina Sales 20 April 2018 (has links)
A tomografia computadorizada por feixe cônico (TCFC) tem apresentado melhores resultados em relação a radiografia convencional no diagnóstico da região de cabeça e pescoço. Porém a presença de artefatos nas imagens tomográficas podem interferir na acurácia do diagnóstico. O presente estudo teve como objetivo avaliar a influência de diferentes tipos de preenchimentos endodônticos na formação de artefato nas imagens de TCFC e avaliar a influência destes no diagnóstico de fratura radicular. Foram utilizados 200 dentes (100 incisivos centrais superiores e 100 prémolares inferiores) subdivididos em 10 grupos diferenciando o tipo de preenchimento endodôntico. Os dentes foram escaneados utilizando um tomógrafo computadorizado por feixe cônico. Inicialmente foi realizada uma medição nas imagens tomográficas com a ferramenta de informação sobre a área (ROI) e avaliação subjetiva das imagens para realizar uma comparação entre os cimentos endodônticos. Após essa fase, 100 dentes foram fraturados para realizar a última análise que foi o diagnóstico de fratura radicular. Para análise dos dados da ferramenta ROI foram utilizados a análise de Kruskal-Wallis e o teste post hoc Dunn, para comparar os dados subjetivos foi utilizado o teste de Kruskal-Wallis e para os dados de diagnóstico de fratura radicular foi calculado a Curva de característica de operação do receptor (ROC) e o teste ANOVA e o teste post hoc Tukey para os valores de área sob a curva (ASC). Resultados: O terço médio foi a região que gerou mais variações na escala de cinza para ambos os dentes. O Pulp Canal Sealer e o Sealer 26 foram os cimentos que mais alteraram as imagens segundo a análise subjetiva. Os valores de ASC variaram de 0.530 a 0.745. Conclusão: Todos os materiais produziram artefato nas imagens por TCFC, dificultando o diagnóstico de fratura radicular. / Cone beam computed tomography (CBCT) has shown better results than conventional radiographs on head and neck diagnosis. However, the presence of artifact in the CBCT images could interfere on diagnosis accuracy. The aim of this study was to evaluate the influence of different types of endodontic fillings and analyze the influence of these materials in root fracture diagnosis. Two hundred teeth (100 superior incisors and 100 inferior premolars) were divided in 10 groups categorized by each typo of endodontic filling. All teeth were scanned by using CBCT device. Initially, a measurement was performed on CBCT images using the Region of Interest (ROI) tool and a subjective analysis of the images was carried on to compare the different endodontic fillings. After this phase, 100 teeth were fractured to perform the last analysis: root fracture diagnosis. Kruskall-Wallis analyses for ROI tool data was performed with the aid of post hoc Dunn test, Kruskal-Wallis test was selected for the subjective data assessment and receiver operating characteristic (ROC) curves were used for root fracture diagnosis analyses and the variance analysis with the post hoc Tukey test for AUC values. The middle third was the region that developed more grayscale variations for both teeth. At the subjective analysis, Pulp Canal Sealer and Sealer 26 were selected as the ones that produced more images alterations. AUC ROC values ranged from 0.530 to 0.745. Conclusion: All materials produced artifact in CBCT images, making the root fracture diagnosis more difficult.
510

Avaliação da resistência à fratura de próteses unitárias sobre implantes revestidas em resina composta laboratorial com reforço de fibras de vidro

FREITAS, Alysson Cruz de January 2008 (has links)
Submitted by Cleide Dantas (cleidedantas@ufpa.br) on 2014-02-14T14:28:37Z No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Dissertacao_AvaliacaoResistenciaFratura.pdf: 953152 bytes, checksum: b5b9de92a57b7fc1e1520c39fa23823f (MD5) / Approved for entry into archive by Ana Rosa Silva (arosa@ufpa.br) on 2014-04-29T15:43:22Z (GMT) No. of bitstreams: 2 Dissertacao_AvaliacaoResistenciaFratura.pdf: 953152 bytes, checksum: b5b9de92a57b7fc1e1520c39fa23823f (MD5) license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) / Made available in DSpace on 2014-04-29T15:43:22Z (GMT). No. of bitstreams: 2 Dissertacao_AvaliacaoResistenciaFratura.pdf: 953152 bytes, checksum: b5b9de92a57b7fc1e1520c39fa23823f (MD5) license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Previous issue date: 2008 / O sucesso dos implantes osseointegrados é comprovado cientificamente e com isso, veio outras preocupações como a de se solucionar esteticamente e funcionalmente o tratamento restaurador, tendo como escolha na maioria das vezes a confecção de coroas metalocerâmicas ou metaloplásticas. Este trabalho teve como objetivo comparar a resistência à fratura por compressão axial e avaliar o tipo de fratura de 30 coroas unitárias sobre implante do primeiro pré-molar superior, confeccionadas com diferentes infraestruturas metálicas (infra-estruturas enceradas e fundidas em níquel-cromo sobre pilares UCLA calcináveis e infra-estruturas representadas por pilares UCLA provisórios pré-fabricados em titânio), ambos restaurados com resina composta laboratorial, sendo que, as restaurações totais em resina compostas laboratoriais confeccionadas sobre o pilar UCLA pré-fabricado em titânio foram reforçadas internamente com fibras de vidro. Não foram encontradas diferenças estatisticamente significantes entre as médias tanto de resistência à fratura quanto da deformação máxima de rompimento entre os grupos (p= 0.5812 e p= 0.1743 respectivamente). As fraturas apresentadas pelos espécimes com infra-estruturas fundidas em níquel-cromo com e sem retenção apresentaram em sua totalidade fraturas parciais adesivas enquanto que no grupo com infra-estruturas com fibras-de-vidro o tipo de fratura foi a parcial coesiva. A resina composta laboratorial suporta forças acima das encontradas na mastigação indiferente do tipo de reforço utilizado, podendo ser indicada para confecção de próteses unitárias sobre implante. / The success of the osseointegrated implants is proved scientifically and with these, other preoccupations came such as to solve the aesthetically and functionally restoring treatment, having like chosen most times the production of metaloceramic or metaloplastic crowns. This work has the objective to compare the fracture resistance for axial compression of 30 single crowns on implant of the first superior pre-molar, made with different metal infrastructures (infrastructures waxed and fused in nickel-chrome on calcinable UCLA pillars and infrastructures represented by titanium prefabricated provisional UCLA pillars), both restored with laboratory compound resin, being that, the total restorations in laboratory compound resin made on the titanium prefabricated provisional UCLA pillars were reinforced internally with fiberglass. They were not found differences statistically significant between the averages so much of fracture resistance as the deformation (p= 0.5812 and p= 0.1743 respectively). The fractures presented by the specimens with infrastructures fused in nickel-chrome with and without retention presented partial adhesive fractures in its entirety whereas in the group with infrastructures with fiberglass the type of fracture was the partial cohesive one. The compound resin laboratorial supports strength above the considered ones in the mastication, indifferent of the type of the used reinforcement, being able to be indicated for production of implants single prosthesis.

Page generated in 0.0647 seconds