• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 11
  • 1
  • Tagged with
  • 13
  • 13
  • 10
  • 8
  • 7
  • 7
  • 6
  • 6
  • 6
  • 6
  • 6
  • 6
  • 6
  • 6
  • 5
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Factors related to vertical root fractures in teeth restored with prosthetic single crowns: A retrospective clinical study

Al-Hotheiry, Sham, Spahic, Mustafa January 2022 (has links)
Purpose The aim of the present retrospective clinical study was to investigate the factors that could be associated with the occurrence of vertical root fractures regarding tooth-supported single crowns (VRF). Materials and methods This dental record-based retrospective study included patients treated with tooth-supported single crowns during from October 2008 to December 2010 at the Faculty of Odontology, Malmö University, Sweden. All patients rehabilitated with one or more tooth-supported single prosthetic crowns during the aforementioned period were included. The patients needed to have at least 6 months of follow-up and an available digital periapical radiograph taken within 12 months after delivery of the prosthesis (crown cementation). Univariate and multivariate Cox regression models were used to evaluate the associations between 14 clinical covariates and VRF. Results Only 96 single-crowns in 72 patients fulfilled the inclusion criteria. The location of teeth, in the mandible in relation to teeth in the maxilla, related to their posterior position in the jaws, was identified in the Cox regression model as being associated with VRF. Conclusion Tooth-supported single crowns located in the mandible, directly related to the fact that they were located posteriorly, was the factor associated with the occurrence of VRF. However, it is not possible to draw robust conclusions about the results of the present study, due to the small sample size of the present cohort, which was a consequence of many difficulties that arouse during the conduction of the study. More available data would be needed in order to answer important questions about external validity of the present results. / Syfte Syftet med den aktuella retrospektiva kliniska studien var att undersöka de faktorer som kan associeras med uppkomsten av vertikala rotfrakturer (VRF) avseende tandstödda singelkronor.Material och metod Denna retrospektiva studie baserades på tandvårdsjournaler och inkluderade patienter som behandlats med tandstödda singelkronor under perioden från oktober 2008 till december 2010 vid Odontologiska fakulteten, Malmö Universitet, Sverige. Alla patienter som behandlades med en eller flera tandstödda protetiska singelkronor under den tidigare nämnda perioden inkluderades. Patienterna behövde ha minst 6 månaders uppföljning och en tillgänglig digital periapikal röntgenbild tagen inom 12 månader efter utlämning av den protetiska ersättningen (kroncementering). Univariata och multivariata Cox-regressionsmodeller användes för att utvärdera sambanden mellan 14 kliniska kovariater och VRF.Resultat Endast 96 singelkronor hos totalt 72 patienter uppfyllde inklusionskriterierna. Förhållandet som identifierades i Cox-regressionsmodellen är att placeringen av tänder i underkäken i förhållande till tänder i överkäken är associerad med VRF, där relationen kunde relateras till den posteriora regionen i underkäken. Slutsats Tanstödda singelkronor installerade i den posteriora regionen i mandibeln, är faktorn som är förknippad med förekomsten av VRF. Det är dock inte möjligt att dra drastiska slutsatser om resultaten av den föreliggande studien på grund av den lilla urvalsstorleken för den nuvarande kohorten, vilket var till följd av många svårigheter som uppstod under genomförandet av studien. Mer tillgängliga data skulle behövas för att besvara viktiga frågor om extern validitet av de nuvarande resultaten.
2

Avaliação de diferentes topografias residuais na distribuição de tensões no remanescente dental por meio da análise de elementos finitos / Different residual topographic analysis in the distribution of tensions in the residual teeth by means of the finite element analysis

Marco Antonio Amorim Vasco 20 December 2007 (has links)
A presença de projeção dentinária acima da linha de término no preparo de dentes tratados endodônticamente para receber núcleos metálicos fundidos é bem fundamentada na literatura, influenciando positivamente na resistência da raiz. Entretanto, devido à destruição dental, nem sempre é possível atingir uma forma de projeção homogênea, contribuindo para deficiências no preparo que podem influenciar na resistência mecânica à fratura. Um incisivo central superior direito foi scaneado com tomografia computadorizada e reconstruído com software específico em um modelo virtual. Este modelo foi editado com diferentes projeções dentinárias, 2 mm acima da linha de término envolvendo projeções: ausente, total, vestibular, palatina e proximal e submetidas à simulação de uma carga mastigatória, no software Ansys Workbench v11, para avaliar a distribuição de tensões geradas no mesmo. As simulações demonstram que os melhores resultados foram obtidas com a projeção total, a projeção palatina obteve resultados muito próximos à total. O pior resultado foi da projeção ausente obtendo resultados muito próximos á projeção vestibular. Os autores nesta pesquisa concluíram que uma projeção dentinária entre o núcleo e a força aplicada é um importante fator para beneficiar a biomecânica do remanescente dental, e que a projeção total fornece o melhor prognóstico nesta situação comparando às diferentes condições. / The presence of dentin projection above the finish line in the preparation of endodonticaly treated tooth to receive post and core is well established in literature, it influences positively in the resistance of the root. However, due to dental destruction, it\'s not always possible to achieve a homogenous projection design, contributing for deficiencies in the preparation that can influence in the mechanical resistance to breaking. A maxillary right central incisor was scanned with computer tomography and reconstructed with specific software into a virtual model. This model was edited with different dentin projections, 2 mm above the preparation line involving absent, total, bucal, palatal and proximal projections and later submitted to simulation of chewing load, in software ANSYS v11, to get the distribution of tensions generated in the same. The simulations show that the best results are when the dentin projection is total, followed closely by the palatal projection. The worse result belongs to the absent projection group followed closely by bucal group. The authors in this research concludes that a dentin projection between the core and the applied force is an important factor to benefit the biomechanical of the remaining anterior teeth, and the whole projection gives the best prognostic comparing the different situations.
3

Avaliação de diferentes topografias residuais na distribuição de tensões no remanescente dental por meio da análise de elementos finitos / Different residual topographic analysis in the distribution of tensions in the residual teeth by means of the finite element analysis

Vasco, Marco Antonio Amorim 20 December 2007 (has links)
A presença de projeção dentinária acima da linha de término no preparo de dentes tratados endodônticamente para receber núcleos metálicos fundidos é bem fundamentada na literatura, influenciando positivamente na resistência da raiz. Entretanto, devido à destruição dental, nem sempre é possível atingir uma forma de projeção homogênea, contribuindo para deficiências no preparo que podem influenciar na resistência mecânica à fratura. Um incisivo central superior direito foi scaneado com tomografia computadorizada e reconstruído com software específico em um modelo virtual. Este modelo foi editado com diferentes projeções dentinárias, 2 mm acima da linha de término envolvendo projeções: ausente, total, vestibular, palatina e proximal e submetidas à simulação de uma carga mastigatória, no software Ansys Workbench v11, para avaliar a distribuição de tensões geradas no mesmo. As simulações demonstram que os melhores resultados foram obtidas com a projeção total, a projeção palatina obteve resultados muito próximos à total. O pior resultado foi da projeção ausente obtendo resultados muito próximos á projeção vestibular. Os autores nesta pesquisa concluíram que uma projeção dentinária entre o núcleo e a força aplicada é um importante fator para beneficiar a biomecânica do remanescente dental, e que a projeção total fornece o melhor prognóstico nesta situação comparando às diferentes condições. / The presence of dentin projection above the finish line in the preparation of endodonticaly treated tooth to receive post and core is well established in literature, it influences positively in the resistance of the root. However, due to dental destruction, it\'s not always possible to achieve a homogenous projection design, contributing for deficiencies in the preparation that can influence in the mechanical resistance to breaking. A maxillary right central incisor was scanned with computer tomography and reconstructed with specific software into a virtual model. This model was edited with different dentin projections, 2 mm above the preparation line involving absent, total, bucal, palatal and proximal projections and later submitted to simulation of chewing load, in software ANSYS v11, to get the distribution of tensions generated in the same. The simulations show that the best results are when the dentin projection is total, followed closely by the palatal projection. The worse result belongs to the absent projection group followed closely by bucal group. The authors in this research concludes that a dentin projection between the core and the applied force is an important factor to benefit the biomechanical of the remaining anterior teeth, and the whole projection gives the best prognostic comparing the different situations.
4

Investigation of selected properties of a resin-based root canal filling material : an in vitro study

Asheibi, Fatma K. January 2014 (has links)
Following chemo-mechanical cleaning of the root canal system, the provision of a fluid-tight seal is one of the main requirements for successful endodontic treatment. Gutta percha with a sealer has been considered as the gold standard root canal filling for many years. However, it does not have all the properties of an ideal root canal filling. A resin-based root filling, Resilon, has been introduced which has the advantage of bonding to the root canal dentine forming a “monoblock”. Different properties of Resilon have been investigated, but some properties using different obturation techniques and in retreatment need further investigation. The aim of this project was to investigate selected properties of Resilon in primary endodontic treatment (quality of obturation using either cold lateral condensation or thermal compaction, and push-out bond strength following the use of different intracanal medicaments) and secondary endodontic treatment (removability using a combination of hand and rotary instrumentation, fracture resistance and leakage resistance following different removal techniques).Using micro-CT, the volume of voids in root canals obturated with Resilon in comparison with gutta percha using either cold lateral condensation or thermal compaction was investigated. The results showed that there was no significant difference between the two materials regardless of the obturation technique. The use of Vitapex and iodoform was found to significantly reduce the bond strength of Resilon to dentine in comparison with calcium hydroxide and its aqueous combination with iodoform (Calcipast1). The effectiveness of the combined use of hand K-files and ProTaper retreatment files in removal of Resilon using either cold lateral condensation or thermal compaction was compared to that of gutta percha. Micro-CT assessment showed that Resilon resulted in significantly more remaining material than gutta percha when thermal compaction was used. Fracture resistance of retreated roots filled with Resilon was found to be not significantly different from those filled with gutta percha irrespective to the removal technique (either hand K-files or ProTaper retreatment files). Using the same retreatment techniques, dye leakage resistance of root canals re-filled with Resilon was compared with that of primarily treated root canals. The results showed that there was no significant difference in leakage resistance between re-treated and primarily treated root canals. Obturation with Resilon was shown to have no significant advantage over gutta percha in terms of quality of obturation and fracture resistance in retreated roots. More investigation of the clinical performance of Resilon is required before it can be considered as a replacement for gutta percha.
5

Avaliação da interferência de artefatos metálicos dentários na visualização da integridade radicular utilizando a Tomografia Computadorizada por Feixe Cônico / Evaluation of interference from dental metallic artifacts on diagnosis of root integrity using cone beam computed tomography

Costa, Felipe Ferreira 12 September 2013 (has links)
O propósito deste estudo foi o de avaliar a acurácia, sensibilidade, especificidade e concordância inter e intra-observador do exame de tomografia computadorizada por feixe cônico (TCFC) na detecção de fraturas radiculares horizontais, na presença e ausência de núcleos metálicos. Foram realizados exames de TCFC em dentes permanentes humanos extraídos e manipulados endodonticamente na presença e ausência de núcleos intracanais. Estes foram inseridos em mandíbula e examinados através de três diferentes tomógrafos de grande e pequeno volume (Picasso Master, PaX-Uni3D e Prexion 3D). Os observadores avaliaram as imagens em um programa de visualização independente e os mesmos deveriam definir precisamente o local das fraturas nas raízes dentárias. Nas amostras avaliadas através do PaX - Uni3D, os valores de acurácia encontrados nas amostras sem núcleo metálico variaram entre 75 a 88%; no Picasso Master, variaram entre 33 a 68% e no Prexion 3D, variaram entre 85 a 90%, no protocolo com 1024 projeções e entre 79 a 85%, no protocolo de 512 projeções. Todos os valores de acurácia encontrados sofreram interferências nas observações das amostras com núcleo metálico. No PaX - Uni3D, os valores encontrados variaram entre 55 a 70%; no Picasso Master, variaram entre 38 a 83% e no Prexion 3D, entre 75 a 90% no grupo de 1024 projeções e entre 70 e 85% no grupo de 512 projeções. O protocolo onde a interferência por artefatos metálicos se deu com maior intensidade foi o do Picasso Master. O protocolo de 1024 projeções de raios-X do Prexion 3D foi o que encontrou menor interferência. A interferência dos artefatos metálicos no diagnóstico de fraturas radiculares horizontais foi comprovada visto que a presença de material metálico intracanal reduziu a acurácia, sensibilidade e especificidade em todos os aparelhos e protocolos utilizados nesta pesquisa. / The purpose of this study was to evaluate the accuracy, sensitivity, specificity and inter and intra-observer concordancy of cone beam computed tomography (CBCT) in the detection of horizontal root fractures in the presence and absence of intracanal metal post (IMP). CBCT exams were performed on endodontically treated teeth in the presence and absence of IMP, using three different devices. These teeth were inserted in a mandible and examined through three different large and small volume scanners (Picasso Master, PaX-Uni3D and Prexion 3D). The observers evaluated the images in a DICOM-viewer software. They should precisely define the location of the horizontal root fracture of the sample. The accuracy values found in samples without IMP evaluated by PaX - Uni3D ranged between 75 and 88%; in Picasso Master ranged between 33 and 68%, and Prexion 3D ranged from 85 to 90% in the protocol with 1024 projections and between 79-85%, in 512 projections protocol. All accuracy values suffered interference in the observations of the samples with IMP. PaX - Uni3D values ranged from 55 to 70%, Picasso Master, from 38 to 83%, and Prexion 3D, between 75 to 90% in the 1024 projections and 70 to 85% in 512 projections group. The protocol where the interference by metallic artifacts occurred with greater intensity was the Picasso Master. The 1024 X-ray projections of Prexion 3D suffered less. The interference of metal artifacts in the diagnosis of horizontal root fractures was confirmed as the presence of intracanal metallic material reduced the accuracy, sensitivity and specificity for all devices and protocols of this research.
6

Avaliação do comportamento de seladores endodônticos e a influência destes materiais sobre o diagnóstico de fraturas radiculares por meio de tomografia computadorizada por feixe cônico / Endodontic fillings behavior evaluation and their influence in root fracture diagnosis by means of cone beam computed tomography

Salineiro, Fernanda Cristina Sales 20 April 2018 (has links)
A tomografia computadorizada por feixe cônico (TCFC) tem apresentado melhores resultados em relação a radiografia convencional no diagnóstico da região de cabeça e pescoço. Porém a presença de artefatos nas imagens tomográficas podem interferir na acurácia do diagnóstico. O presente estudo teve como objetivo avaliar a influência de diferentes tipos de preenchimentos endodônticos na formação de artefato nas imagens de TCFC e avaliar a influência destes no diagnóstico de fratura radicular. Foram utilizados 200 dentes (100 incisivos centrais superiores e 100 prémolares inferiores) subdivididos em 10 grupos diferenciando o tipo de preenchimento endodôntico. Os dentes foram escaneados utilizando um tomógrafo computadorizado por feixe cônico. Inicialmente foi realizada uma medição nas imagens tomográficas com a ferramenta de informação sobre a área (ROI) e avaliação subjetiva das imagens para realizar uma comparação entre os cimentos endodônticos. Após essa fase, 100 dentes foram fraturados para realizar a última análise que foi o diagnóstico de fratura radicular. Para análise dos dados da ferramenta ROI foram utilizados a análise de Kruskal-Wallis e o teste post hoc Dunn, para comparar os dados subjetivos foi utilizado o teste de Kruskal-Wallis e para os dados de diagnóstico de fratura radicular foi calculado a Curva de característica de operação do receptor (ROC) e o teste ANOVA e o teste post hoc Tukey para os valores de área sob a curva (ASC). Resultados: O terço médio foi a região que gerou mais variações na escala de cinza para ambos os dentes. O Pulp Canal Sealer e o Sealer 26 foram os cimentos que mais alteraram as imagens segundo a análise subjetiva. Os valores de ASC variaram de 0.530 a 0.745. Conclusão: Todos os materiais produziram artefato nas imagens por TCFC, dificultando o diagnóstico de fratura radicular. / Cone beam computed tomography (CBCT) has shown better results than conventional radiographs on head and neck diagnosis. However, the presence of artifact in the CBCT images could interfere on diagnosis accuracy. The aim of this study was to evaluate the influence of different types of endodontic fillings and analyze the influence of these materials in root fracture diagnosis. Two hundred teeth (100 superior incisors and 100 inferior premolars) were divided in 10 groups categorized by each typo of endodontic filling. All teeth were scanned by using CBCT device. Initially, a measurement was performed on CBCT images using the Region of Interest (ROI) tool and a subjective analysis of the images was carried on to compare the different endodontic fillings. After this phase, 100 teeth were fractured to perform the last analysis: root fracture diagnosis. Kruskall-Wallis analyses for ROI tool data was performed with the aid of post hoc Dunn test, Kruskal-Wallis test was selected for the subjective data assessment and receiver operating characteristic (ROC) curves were used for root fracture diagnosis analyses and the variance analysis with the post hoc Tukey test for AUC values. The middle third was the region that developed more grayscale variations for both teeth. At the subjective analysis, Pulp Canal Sealer and Sealer 26 were selected as the ones that produced more images alterations. AUC ROC values ranged from 0.530 to 0.745. Conclusion: All materials produced artifact in CBCT images, making the root fracture diagnosis more difficult.
7

Avaliação do comportamento de seladores endodônticos e a influência destes materiais sobre o diagnóstico de fraturas radiculares por meio de tomografia computadorizada por feixe cônico / Endodontic fillings behavior evaluation and their influence in root fracture diagnosis by means of cone beam computed tomography

Fernanda Cristina Sales Salineiro 20 April 2018 (has links)
A tomografia computadorizada por feixe cônico (TCFC) tem apresentado melhores resultados em relação a radiografia convencional no diagnóstico da região de cabeça e pescoço. Porém a presença de artefatos nas imagens tomográficas podem interferir na acurácia do diagnóstico. O presente estudo teve como objetivo avaliar a influência de diferentes tipos de preenchimentos endodônticos na formação de artefato nas imagens de TCFC e avaliar a influência destes no diagnóstico de fratura radicular. Foram utilizados 200 dentes (100 incisivos centrais superiores e 100 prémolares inferiores) subdivididos em 10 grupos diferenciando o tipo de preenchimento endodôntico. Os dentes foram escaneados utilizando um tomógrafo computadorizado por feixe cônico. Inicialmente foi realizada uma medição nas imagens tomográficas com a ferramenta de informação sobre a área (ROI) e avaliação subjetiva das imagens para realizar uma comparação entre os cimentos endodônticos. Após essa fase, 100 dentes foram fraturados para realizar a última análise que foi o diagnóstico de fratura radicular. Para análise dos dados da ferramenta ROI foram utilizados a análise de Kruskal-Wallis e o teste post hoc Dunn, para comparar os dados subjetivos foi utilizado o teste de Kruskal-Wallis e para os dados de diagnóstico de fratura radicular foi calculado a Curva de característica de operação do receptor (ROC) e o teste ANOVA e o teste post hoc Tukey para os valores de área sob a curva (ASC). Resultados: O terço médio foi a região que gerou mais variações na escala de cinza para ambos os dentes. O Pulp Canal Sealer e o Sealer 26 foram os cimentos que mais alteraram as imagens segundo a análise subjetiva. Os valores de ASC variaram de 0.530 a 0.745. Conclusão: Todos os materiais produziram artefato nas imagens por TCFC, dificultando o diagnóstico de fratura radicular. / Cone beam computed tomography (CBCT) has shown better results than conventional radiographs on head and neck diagnosis. However, the presence of artifact in the CBCT images could interfere on diagnosis accuracy. The aim of this study was to evaluate the influence of different types of endodontic fillings and analyze the influence of these materials in root fracture diagnosis. Two hundred teeth (100 superior incisors and 100 inferior premolars) were divided in 10 groups categorized by each typo of endodontic filling. All teeth were scanned by using CBCT device. Initially, a measurement was performed on CBCT images using the Region of Interest (ROI) tool and a subjective analysis of the images was carried on to compare the different endodontic fillings. After this phase, 100 teeth were fractured to perform the last analysis: root fracture diagnosis. Kruskall-Wallis analyses for ROI tool data was performed with the aid of post hoc Dunn test, Kruskal-Wallis test was selected for the subjective data assessment and receiver operating characteristic (ROC) curves were used for root fracture diagnosis analyses and the variance analysis with the post hoc Tukey test for AUC values. The middle third was the region that developed more grayscale variations for both teeth. At the subjective analysis, Pulp Canal Sealer and Sealer 26 were selected as the ones that produced more images alterations. AUC ROC values ranged from 0.530 to 0.745. Conclusion: All materials produced artifact in CBCT images, making the root fracture diagnosis more difficult.
8

Avaliação da interferência de artefatos metálicos dentários na visualização da integridade radicular utilizando a Tomografia Computadorizada por Feixe Cônico / Evaluation of interference from dental metallic artifacts on diagnosis of root integrity using cone beam computed tomography

Felipe Ferreira Costa 12 September 2013 (has links)
O propósito deste estudo foi o de avaliar a acurácia, sensibilidade, especificidade e concordância inter e intra-observador do exame de tomografia computadorizada por feixe cônico (TCFC) na detecção de fraturas radiculares horizontais, na presença e ausência de núcleos metálicos. Foram realizados exames de TCFC em dentes permanentes humanos extraídos e manipulados endodonticamente na presença e ausência de núcleos intracanais. Estes foram inseridos em mandíbula e examinados através de três diferentes tomógrafos de grande e pequeno volume (Picasso Master, PaX-Uni3D e Prexion 3D). Os observadores avaliaram as imagens em um programa de visualização independente e os mesmos deveriam definir precisamente o local das fraturas nas raízes dentárias. Nas amostras avaliadas através do PaX - Uni3D, os valores de acurácia encontrados nas amostras sem núcleo metálico variaram entre 75 a 88%; no Picasso Master, variaram entre 33 a 68% e no Prexion 3D, variaram entre 85 a 90%, no protocolo com 1024 projeções e entre 79 a 85%, no protocolo de 512 projeções. Todos os valores de acurácia encontrados sofreram interferências nas observações das amostras com núcleo metálico. No PaX - Uni3D, os valores encontrados variaram entre 55 a 70%; no Picasso Master, variaram entre 38 a 83% e no Prexion 3D, entre 75 a 90% no grupo de 1024 projeções e entre 70 e 85% no grupo de 512 projeções. O protocolo onde a interferência por artefatos metálicos se deu com maior intensidade foi o do Picasso Master. O protocolo de 1024 projeções de raios-X do Prexion 3D foi o que encontrou menor interferência. A interferência dos artefatos metálicos no diagnóstico de fraturas radiculares horizontais foi comprovada visto que a presença de material metálico intracanal reduziu a acurácia, sensibilidade e especificidade em todos os aparelhos e protocolos utilizados nesta pesquisa. / The purpose of this study was to evaluate the accuracy, sensitivity, specificity and inter and intra-observer concordancy of cone beam computed tomography (CBCT) in the detection of horizontal root fractures in the presence and absence of intracanal metal post (IMP). CBCT exams were performed on endodontically treated teeth in the presence and absence of IMP, using three different devices. These teeth were inserted in a mandible and examined through three different large and small volume scanners (Picasso Master, PaX-Uni3D and Prexion 3D). The observers evaluated the images in a DICOM-viewer software. They should precisely define the location of the horizontal root fracture of the sample. The accuracy values found in samples without IMP evaluated by PaX - Uni3D ranged between 75 and 88%; in Picasso Master ranged between 33 and 68%, and Prexion 3D ranged from 85 to 90% in the protocol with 1024 projections and between 79-85%, in 512 projections protocol. All accuracy values suffered interference in the observations of the samples with IMP. PaX - Uni3D values ranged from 55 to 70%, Picasso Master, from 38 to 83%, and Prexion 3D, between 75 to 90% in the 1024 projections and 70 to 85% in 512 projections group. The protocol where the interference by metallic artifacts occurred with greater intensity was the Picasso Master. The 1024 X-ray projections of Prexion 3D suffered less. The interference of metal artifacts in the diagnosis of horizontal root fractures was confirmed as the presence of intracanal metallic material reduced the accuracy, sensitivity and specificity for all devices and protocols of this research.
9

EFEITO DO TIPO DE INSTRUMENTO E DA TÉCNICA OBTURADORA NA RESISTÊNCIA À FRATURA DE DENTES RESTAURADOS. / EFFECT OF THE INSTRUMENT TYPE AND ROOT CANAL FILLING TECHNIQUE ON FRACTURE RESISTANCE OF RESTORED ROOTS

Santini, Manuela Favarin 03 March 2012 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The aim of this study was to assess the effect of instrument type (K-files and nickel-titanium rotary files) and the root canal filling technique (active and passive lateral condensation) on fracture resistance. Sixty eight teeth (canines and premolars) were divided into 4 groups (n=17): G1 - hand instrumentation and active lateral condensation; G2 - hand instrumentation and passive lateral condensation; G3 - rotary instrumentation and active lateral condensation; G4 - rotary instrumentation and passive lateral condensation. Before the filling, the roots were embedded in acrylic resin to simulate the periodontal ligament using a polyether impression material. Every root was restored with glass fiber post and metallic crown. The specimens were mechanical cycled (500.000 cycles, 45°, 37° C, 133 N, 2 Hz) and they were submitted to fracture test (45º, 1 mm/ min) until the fracture occurred. The Kruskal-Wallis test showed that the groups were not different from each other (p = 0. 247). In situations where an endodontic post is required, the instrument type and the obturation technique seem to have no influence on fracture resistance. / O objetivo deste estudo foi avaliar o efeito do tipo de instrumento (limas manuais tipo K e instrumentos rotatórios de NiTi) e da técnica obturadora (condensação lateral ativa e condensação lateral passiva) na resistência à fratura. Para isso, 68 dentes (caninos e pré-molares) foram divididos em 4 grupos (n=17): G1 - instrumentação manual e condensação lateral ativa; G2 - instrumentação manual e condensação lateral passiva; G3 - instrumentação rotatória e condensação lateral ativa; G4 - instrumentação rotatória e condensação lateral passiva. Antes da etapa obturadora, as raízes foram embutidas em resina acrílica para a simulação do ligamento periodontal com material de moldagem à base de poliéter. Todas as raízes foram restauradas com pino de fibra de vidro e coroa metálica. Os espécimes foram submetidos à ciclagem mecânica (500.000 ciclos, 45°, 37° C, 133 N, 2 Hz) e ao teste de resistência à fratura (45º, 1 mm/ min) até a falha ocorrer. O teste de Kruskal-Wallis mostrou que os grupos não foram diferentes entre si (p = 0, 247). Em situações em que há a necessidade de cimentação de pino intrarradicular, a escolha do tipo de instrumento e da técnica obturadora parece não ter influência na resistência à fratura.
10

Acurácia de dois tomógrafos na detecção de fraturas radiculares verticais em dentes com retentores metálicos intracanais / Accuracy of two cone beam computed tomography systems for the detection of vertical root fractures

Siqueira, Claudeir Felipe de Oliveira 10 March 2017 (has links)
Submitted by Luciana Ferreira (lucgeral@gmail.com) on 2017-04-19T12:09:37Z No. of bitstreams: 2 Dissertação - Claudeir Felipe de Oliveira Siqueira - 2017.pdf: 2068338 bytes, checksum: b1222b1c483b31d5a02f7ca3259bb2aa (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2017-04-19T12:13:10Z (GMT) No. of bitstreams: 2 Dissertação - Claudeir Felipe de Oliveira Siqueira - 2017.pdf: 2068338 bytes, checksum: b1222b1c483b31d5a02f7ca3259bb2aa (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2017-04-19T12:13:10Z (GMT). No. of bitstreams: 2 Dissertação - Claudeir Felipe de Oliveira Siqueira - 2017.pdf: 2068338 bytes, checksum: b1222b1c483b31d5a02f7ca3259bb2aa (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2017-03-10 / Conselho Nacional de Pesquisa e Desenvolvimento Científico e Tecnológico - CNPq / Vertical root fracture (VRF) is a dental lesion with worse prognosis in dentistry, the diagnosis is made from clinical evaluation, and image exams, clinically the symptoms are signaled and not pathognomonic and even with the introduction of cone beam computed tomography, the metallic artifacts resulting from the images obtained still make it difficult to detect VRF. The aim of this study was to evaluate the accumulation of Eagle 3D and i-Cat tomography in the detection of VRF in endodontically treated single-root teeth with post metallic intracanal. This study was approved by the Research Ethics Committee of UFG under the number 477.315. 30 single-root teeth were endodontically treated and prepared with metal pins. The sample was divided randomly in Control Group (CTL) and Fractured Group (FRT). The fractures were made only in FRT Group by the Universal Test machine, with load cell 500N and speed of 1mm/ min. The teeth were placed in dry jaw and placed in a vessel with distilled water to be purchased as TCFC images by Eagle 3D tomographs (protocol 1: FOV 5X5 cm and voxel: 0.1 mm - protocol 2: FOV 6X8 cm and voxel: 0.16 mm) and i-CAT (protocol 3: FOV 8 × 8 cm and voxel: 0.125 mm - protocol 4: FOV 8 × 8 cm and voxel: 0.2 mm). Two experienced evaluators classified as composite images by absence of fracture or by subjective revisions of an interference of the formation of non-diagnostic artefacts and reconstruction type and efficient in the detection of VRF. The inter-examiner agreement was verified by kappa test. Measurements of sensitivity, specificity and accuracy were adopted for each device. The area under the ROC curve was also calculated and compared using the ANOVA. The results indicated that protocols 1 and 3 were more accurate (AUC protocol 1: 0.784 - p <0.05 and AUC protocol 2: 0.729 - p <0.05). According to the subjective evaluation of the examiners, in protocols 1 and 4 of greater interference of the formation of artifacts without diagnosis of VRF and a parasagittal reconstruction was the most efficient for a detection of the fracture line. It is concluded that protocols 1 and 3 highlight a better performance in the detection of VRF and that the size of voxel is a factor that directly influences the accuracy. / Resumo: A fratura radicular vertical (FRV) é a lesão dentária com o pior prognóstico na Odontologia. O diagnóstico é um desafio, pois clinicamente os pacientes apresentam sinais e sintomas não patognomônicos e apesar da introdução da tomografia computadorizada de feixe cônico (TCFC) como ferramenta de diagnóstico , os artefatos metálicos resultantes das imagens obtidas tornam difícil a detecção da FRV. Vários fatores de digitalização e reconstrução incluindo FOV (Field of view), tamanho do voxel, o número de projeções base (aquisições) para a reconstrução e a formação de artefatos na imagem tem influência significativa na acurácia do exame. O objetivo deste trabalho foi avaliar a acurácia dos tomógrafos Eagle 3D e i-Cat na detecção de FRV em dentes unirradiculares tratados endodonticamente com retentor metálico intracanal. Foram tratados endodonticamente e confeccionados pinos metálicos em 30 dentes unirradiculares. A amostra foi randomicamente dividida em dois grupos: Grupo Controle (CTL) e Grupo Fraturado (FRT). As fraturas foram confeccionadas somente no Grupo FRT pela Máquina de Ensaios Universal, com célula de carga 500N e velocidade de 1mm/min. Os dentes foram posicionados em mandíbula seca e colocados em um recipiente com água destilada para serem adquiridas as imagens de TCFC pelos tomógrafos Eagle 3D (protocolo 1: FOV 5X5 cm e voxel: 0,1 mm - protocolo 2: FOV 6X8 cm e voxel: 0,16 mm) e i-CAT (protocolo 3: FOV 8X8 cm e voxel: 0,125 mm - protocolo 4: FOV 8X8 cm e voxel: 0,2 mm). Dois avaliadores experientes classificaram as imagens conforme a presença ou ausência de fratura e avaliaram a interferência dos artefatos e do tipo de reconstrução na detecção de FRV. A concordância interexaminador foi verificada pelo teste kappa. As medidas de sensibilidade, especificidade e acurácia foram medidas para cada aparelho. Também foi calculada a área sob a curva (AUC) ROC, e os resultados comparados utilizando o modelo de análise variância (ANOVA). Os resultados indicaram que os protocolos 1 e 3 foram mais acurados (AUC protocolo 1: 0,784 – p<0,05 e AUC protocolo 2: 0,729 – p<0,05). Segundo avaliação subjetiva dos examinadores, nos protocolos 1 e 4 há maior interferência da formação de artefatos no diagnóstico de FRV e a reconstrução transversal se mostrou mais eficiente para a detecção da linha de fratura. Conclui-se que os protocolos 1 (Eagle 3D: FOV 5X5 cm e voxel: 0,1 mm) e 3 (i-CAT: FOV 8X8 cm e voxel: 0,125 mm) apresentam melhor acurácia na detecção de FRV e que o tamanho do voxel é um fator que influência diretamente na acurácia

Page generated in 0.0758 seconds