Spelling suggestions: "subject:"case estacionário quiral"" "subject:"base estacionário quiral""
1 |
Desenvolvimento de fases estacionárias quirais para cromatografia líquida de alta eficiência a partir de polipirróis e politiofenos contendo centros estereogênicosMaria Monteiro Dias, Jéssica 31 January 2011 (has links)
Made available in DSpace on 2014-06-12T22:57:15Z (GMT). No. of bitstreams: 2
arquivo4112_1.pdf: 3452351 bytes, checksum: b46bb5109550a7997e5cc3e7b1bfb313 (MD5)
license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5)
Previous issue date: 2011 / Faculdade de Amparo à Ciência e Tecnologia do Estado de Pernambuco / A utilização de polímeros condutores, polipirrol e politiofeno, foi investigada na
preparação de fases estacionárias quirais aplicadas à cromatografia líquida de alta eficiência. O
seletor do tipo Pirkle , R-(-)-N-(3 ,5 -dinitrobenzoil)-α-fenilglicina, já descrito na literatura
para resolução de uma grande variedade de compostos, foi utilizado na preparação dos
monômeros de pirrol e tiofeno, R-(-)-N-(3 ,5 -dinitrobenzoil)-α-fenilglicinato de 3-(1 -
pirrolil)propila e R-(-)-N-(3,5-Dinitrobenzoil)-α-fenilglicinato de 2 -(3 -tienil)etila com
rendimentos de 60 e 68%, respectivamente.
Através de uma rota heterogênea, o agente sililante N-β-aminoetil-γ-amino-propiltrimetoxissilano
foi ligado covalentemente à sílica de forma bidentada e posteriormente
modificada com os grupos 1-(3 -iodopropil)pirrol e 2-(3 -iodoetil)tiofeno, que funcionaram
como âncora entre a sílica e os respectivos polímeros (polipirrol e politiofeno).
As fases estacionárias foram obtidas a partir da copolimerização entre os
monômeros preparados e a sílica modificada, em suspensão de cloreto férrico e clorofórmio. Os
copolímeros de pirrol e tiofeno obtidos foram caracterizados por análise elementar, análise
termogravimétrica, espectroscopia no infravermelho e ressonância magnética nuclear em
estado sólido, onde se pode estudar a estrutura do copolímero e da superfície da sílica.
A aplicação da fase estacionária quiral sintetizada foi realizada a partir do
empacotamento das colunas e ensaios cromatográficos em colaboração com o grupo da
Professora Quézia B. Cass do laboratório de Síntese Orgânica e CLAE - Departamento de
Química- UFSCar. As colunas cromatográficas sintetizadas não apresentaram atividade na
separação enantioseletiva de algumas misturas racêmicas testadas, mesmo na presença de
diferentes fases móveis. Nós suspeitamos que esta inatividade quiral é devido à forte interação
entre os grupos seletores causada por sua proximidade
|
2 |
Análise estereosseletiva do cloridrato de cis-tramadol e de suas impurezas em matéria-prima e formulação farmacêutica / Estereoselective analysis of cis-tramadol hydrocloride and its impurities in raw material and pharmaceutical formulationBernardo, Naíssa Prévide 10 October 2008 (has links)
O cloridrato de tramadol, analgésico sintético de ação central, possui dois centros quirais: o isômero cis é ativo e o isômero trans é uma impureza de processo. Ambos os enantiômeros do cloridrato de cis-tramadol contribuem para o efeito analgésico, mas através de mecanismos diferentes, complementares e interativos farmacologicamente. Os dois isômeros do cis-tramadol apresentam efeitos terapêuticos, e a presença de impurezas, incluindo os isômeros trans - decorrentes do processo de síntese ou devido à decomposição - podem comprometer a qualidade do produto comercializado. Assim, este trabalho teve como objetivo desenvolver e validar metodologia estereosseletiva para análise do cloridrato de cis-tramadol e das possíveis impurezas quirais ou não na matéria-prima e formulações farmacêuticas. Para a separação e quantificação dos enantiômeros do cloridrato de cis-tramadol e das impurezas trans-tramadol, 1,2-olefina e 1,6-olefina, foi utilizada a coluna Chiralcel® OD-H, fase móvel constituída por hexano (60% e 100% de n-hexano, 1:1, v/v):isopropanol:dietilamina:ácido trifluoracético (99,5:0,5:0,3:0,1, v/v/v/v), na vazão de 0,7 mL min-1 e detecção em 274 nm. A coluna Chiralpak® AD fase móvel constituída por hexano (60% de n-hexano):etanol absoluto:dietilamina (95:5:0,1, v/v/v), na vazão de 1,0 mL min-1 e o comprimento de onda para detecção dos compostos foi de 228 nm foi utilizada para a separação e quantificação das impurezas O-desmetiltramadol, N-desmetiltramadol e tramadol N-óxido. Os métodos desenvolvidos foram devidamente validados através dos parâmetros seletividade, linearidade, precisão, exatidão, intervalo, limite de detecção e limite de quantificação. Os resultados obtidos na validação mostraram que os métodos são adequados para a determinação do cis-tramadol e de suas impurezas na matéria prima e na formulação farmacêutica. / Tramadol hydrochloride is a centrally acting analgesic with two chiral centers; the cis isomer is the active drug and the trans isomer is a process impurity. Both enantiomers of cis-tramadol hydrochloride contribute to the analgesic effect through different, but complementary and interactive pharmacological mechanisms. Although both isomers of cis-tramadol hydrochloride show therapeutic effects, the presence of impurities, originated from the synthesis process or due to degradation, can compromise the quality of the marketed product. The aim of this present work was the development and validation of a stereosselective methodology for the analysis of the drug cis-tramadol hydrochloride and the possible chiral or non-chiral impurities in raw materials and pharmaceutical formulations. The separation and quantitation of cis-tramadol enantiomers and the impurities trans-tramadol, 1,2-olefin and 1,6-olefin were carried out using a Chiralcel® OD-H column, mobile phase of hexane (60% and 100% of n-hexane, 1:1, v/v):2-propanol:diethylamine:trifluoroacetic acid (99,5:0,5:0,3:0,1, v/v/v/v) at a flow rate of 0,7 mL min-1 and detection at 274 nm. For the separation and quantitation of the impurities O-desmethyltramadol, N-desmethyltramadol and tramadol N-oxide, a Chiralpak® AD column was used with a mobile phase of hexane (60% of n-hexane):ethanol absolute: diethylamine (95:5:0,1, v/v/v) at a flow rate of 1,0 mL min-1 and detection at 228 nm. The methods were validated using the parameters selectivity, linearity, precision, accuracy, range, detection limit and quantitation limit. The results obtained show that the methods are suitable for the analysis of cis-tramadol and its impurities in raw material and pharmaceutical formulation.
|
3 |
Análise estereosseletiva do cloridrato de cis-tramadol e de suas impurezas em matéria-prima e formulação farmacêutica / Estereoselective analysis of cis-tramadol hydrocloride and its impurities in raw material and pharmaceutical formulationNaíssa Prévide Bernardo 10 October 2008 (has links)
O cloridrato de tramadol, analgésico sintético de ação central, possui dois centros quirais: o isômero cis é ativo e o isômero trans é uma impureza de processo. Ambos os enantiômeros do cloridrato de cis-tramadol contribuem para o efeito analgésico, mas através de mecanismos diferentes, complementares e interativos farmacologicamente. Os dois isômeros do cis-tramadol apresentam efeitos terapêuticos, e a presença de impurezas, incluindo os isômeros trans - decorrentes do processo de síntese ou devido à decomposição - podem comprometer a qualidade do produto comercializado. Assim, este trabalho teve como objetivo desenvolver e validar metodologia estereosseletiva para análise do cloridrato de cis-tramadol e das possíveis impurezas quirais ou não na matéria-prima e formulações farmacêuticas. Para a separação e quantificação dos enantiômeros do cloridrato de cis-tramadol e das impurezas trans-tramadol, 1,2-olefina e 1,6-olefina, foi utilizada a coluna Chiralcel® OD-H, fase móvel constituída por hexano (60% e 100% de n-hexano, 1:1, v/v):isopropanol:dietilamina:ácido trifluoracético (99,5:0,5:0,3:0,1, v/v/v/v), na vazão de 0,7 mL min-1 e detecção em 274 nm. A coluna Chiralpak® AD fase móvel constituída por hexano (60% de n-hexano):etanol absoluto:dietilamina (95:5:0,1, v/v/v), na vazão de 1,0 mL min-1 e o comprimento de onda para detecção dos compostos foi de 228 nm foi utilizada para a separação e quantificação das impurezas O-desmetiltramadol, N-desmetiltramadol e tramadol N-óxido. Os métodos desenvolvidos foram devidamente validados através dos parâmetros seletividade, linearidade, precisão, exatidão, intervalo, limite de detecção e limite de quantificação. Os resultados obtidos na validação mostraram que os métodos são adequados para a determinação do cis-tramadol e de suas impurezas na matéria prima e na formulação farmacêutica. / Tramadol hydrochloride is a centrally acting analgesic with two chiral centers; the cis isomer is the active drug and the trans isomer is a process impurity. Both enantiomers of cis-tramadol hydrochloride contribute to the analgesic effect through different, but complementary and interactive pharmacological mechanisms. Although both isomers of cis-tramadol hydrochloride show therapeutic effects, the presence of impurities, originated from the synthesis process or due to degradation, can compromise the quality of the marketed product. The aim of this present work was the development and validation of a stereosselective methodology for the analysis of the drug cis-tramadol hydrochloride and the possible chiral or non-chiral impurities in raw materials and pharmaceutical formulations. The separation and quantitation of cis-tramadol enantiomers and the impurities trans-tramadol, 1,2-olefin and 1,6-olefin were carried out using a Chiralcel® OD-H column, mobile phase of hexane (60% and 100% of n-hexane, 1:1, v/v):2-propanol:diethylamine:trifluoroacetic acid (99,5:0,5:0,3:0,1, v/v/v/v) at a flow rate of 0,7 mL min-1 and detection at 274 nm. For the separation and quantitation of the impurities O-desmethyltramadol, N-desmethyltramadol and tramadol N-oxide, a Chiralpak® AD column was used with a mobile phase of hexane (60% of n-hexane):ethanol absolute: diethylamine (95:5:0,1, v/v/v) at a flow rate of 1,0 mL min-1 and detection at 228 nm. The methods were validated using the parameters selectivity, linearity, precision, accuracy, range, detection limit and quantitation limit. The results obtained show that the methods are suitable for the analysis of cis-tramadol and its impurities in raw material and pharmaceutical formulation.
|
Page generated in 0.1022 seconds