• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Desenvolvimento de fases estacionárias quirais para cromatografia líquida de alta eficiência a partir de polipirróis e politiofenos contendo centros estereogênicos

Maria Monteiro Dias, Jéssica 31 January 2011 (has links)
Made available in DSpace on 2014-06-12T22:57:15Z (GMT). No. of bitstreams: 2 arquivo4112_1.pdf: 3452351 bytes, checksum: b46bb5109550a7997e5cc3e7b1bfb313 (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2011 / Faculdade de Amparo à Ciência e Tecnologia do Estado de Pernambuco / A utilização de polímeros condutores, polipirrol e politiofeno, foi investigada na preparação de fases estacionárias quirais aplicadas à cromatografia líquida de alta eficiência. O seletor do tipo Pirkle , R-(-)-N-(3 ,5 -dinitrobenzoil)-α-fenilglicina, já descrito na literatura para resolução de uma grande variedade de compostos, foi utilizado na preparação dos monômeros de pirrol e tiofeno, R-(-)-N-(3 ,5 -dinitrobenzoil)-α-fenilglicinato de 3-(1 - pirrolil)propila e R-(-)-N-(3,5-Dinitrobenzoil)-α-fenilglicinato de 2 -(3 -tienil)etila com rendimentos de 60 e 68%, respectivamente. Através de uma rota heterogênea, o agente sililante N-β-aminoetil-γ-amino-propiltrimetoxissilano foi ligado covalentemente à sílica de forma bidentada e posteriormente modificada com os grupos 1-(3 -iodopropil)pirrol e 2-(3 -iodoetil)tiofeno, que funcionaram como âncora entre a sílica e os respectivos polímeros (polipirrol e politiofeno). As fases estacionárias foram obtidas a partir da copolimerização entre os monômeros preparados e a sílica modificada, em suspensão de cloreto férrico e clorofórmio. Os copolímeros de pirrol e tiofeno obtidos foram caracterizados por análise elementar, análise termogravimétrica, espectroscopia no infravermelho e ressonância magnética nuclear em estado sólido, onde se pode estudar a estrutura do copolímero e da superfície da sílica. A aplicação da fase estacionária quiral sintetizada foi realizada a partir do empacotamento das colunas e ensaios cromatográficos em colaboração com o grupo da Professora Quézia B. Cass do laboratório de Síntese Orgânica e CLAE - Departamento de Química- UFSCar. As colunas cromatográficas sintetizadas não apresentaram atividade na separação enantioseletiva de algumas misturas racêmicas testadas, mesmo na presença de diferentes fases móveis. Nós suspeitamos que esta inatividade quiral é devido à forte interação entre os grupos seletores causada por sua proximidade
2

Análise estereosseletiva do cloridrato de cis-tramadol e de suas impurezas em matéria-prima e formulação farmacêutica / Estereoselective analysis of cis-tramadol hydrocloride and its impurities in raw material and pharmaceutical formulation

Bernardo, Naíssa Prévide 10 October 2008 (has links)
O cloridrato de tramadol, analgésico sintético de ação central, possui dois centros quirais: o isômero cis é ativo e o isômero trans é uma impureza de processo. Ambos os enantiômeros do cloridrato de cis-tramadol contribuem para o efeito analgésico, mas através de mecanismos diferentes, complementares e interativos farmacologicamente. Os dois isômeros do cis-tramadol apresentam efeitos terapêuticos, e a presença de impurezas, incluindo os isômeros trans - decorrentes do processo de síntese ou devido à decomposição - podem comprometer a qualidade do produto comercializado. Assim, este trabalho teve como objetivo desenvolver e validar metodologia estereosseletiva para análise do cloridrato de cis-tramadol e das possíveis impurezas quirais ou não na matéria-prima e formulações farmacêuticas. Para a separação e quantificação dos enantiômeros do cloridrato de cis-tramadol e das impurezas trans-tramadol, 1,2-olefina e 1,6-olefina, foi utilizada a coluna Chiralcel® OD-H, fase móvel constituída por hexano (60% e 100% de n-hexano, 1:1, v/v):isopropanol:dietilamina:ácido trifluoracético (99,5:0,5:0,3:0,1, v/v/v/v), na vazão de 0,7 mL min-1 e detecção em 274 nm. A coluna Chiralpak® AD fase móvel constituída por hexano (60% de n-hexano):etanol absoluto:dietilamina (95:5:0,1, v/v/v), na vazão de 1,0 mL min-1 e o comprimento de onda para detecção dos compostos foi de 228 nm foi utilizada para a separação e quantificação das impurezas O-desmetiltramadol, N-desmetiltramadol e tramadol N-óxido. Os métodos desenvolvidos foram devidamente validados através dos parâmetros seletividade, linearidade, precisão, exatidão, intervalo, limite de detecção e limite de quantificação. Os resultados obtidos na validação mostraram que os métodos são adequados para a determinação do cis-tramadol e de suas impurezas na matéria prima e na formulação farmacêutica. / Tramadol hydrochloride is a centrally acting analgesic with two chiral centers; the cis isomer is the active drug and the trans isomer is a process impurity. Both enantiomers of cis-tramadol hydrochloride contribute to the analgesic effect through different, but complementary and interactive pharmacological mechanisms. Although both isomers of cis-tramadol hydrochloride show therapeutic effects, the presence of impurities, originated from the synthesis process or due to degradation, can compromise the quality of the marketed product. The aim of this present work was the development and validation of a stereosselective methodology for the analysis of the drug cis-tramadol hydrochloride and the possible chiral or non-chiral impurities in raw materials and pharmaceutical formulations. The separation and quantitation of cis-tramadol enantiomers and the impurities trans-tramadol, 1,2-olefin and 1,6-olefin were carried out using a Chiralcel® OD-H column, mobile phase of hexane (60% and 100% of n-hexane, 1:1, v/v):2-propanol:diethylamine:trifluoroacetic acid (99,5:0,5:0,3:0,1, v/v/v/v) at a flow rate of 0,7 mL min-1 and detection at 274 nm. For the separation and quantitation of the impurities O-desmethyltramadol, N-desmethyltramadol and tramadol N-oxide, a Chiralpak® AD column was used with a mobile phase of hexane (60% of n-hexane):ethanol absolute: diethylamine (95:5:0,1, v/v/v) at a flow rate of 1,0 mL min-1 and detection at 228 nm. The methods were validated using the parameters selectivity, linearity, precision, accuracy, range, detection limit and quantitation limit. The results obtained show that the methods are suitable for the analysis of cis-tramadol and its impurities in raw material and pharmaceutical formulation.
3

Análise estereosseletiva do cloridrato de cis-tramadol e de suas impurezas em matéria-prima e formulação farmacêutica / Estereoselective analysis of cis-tramadol hydrocloride and its impurities in raw material and pharmaceutical formulation

Naíssa Prévide Bernardo 10 October 2008 (has links)
O cloridrato de tramadol, analgésico sintético de ação central, possui dois centros quirais: o isômero cis é ativo e o isômero trans é uma impureza de processo. Ambos os enantiômeros do cloridrato de cis-tramadol contribuem para o efeito analgésico, mas através de mecanismos diferentes, complementares e interativos farmacologicamente. Os dois isômeros do cis-tramadol apresentam efeitos terapêuticos, e a presença de impurezas, incluindo os isômeros trans - decorrentes do processo de síntese ou devido à decomposição - podem comprometer a qualidade do produto comercializado. Assim, este trabalho teve como objetivo desenvolver e validar metodologia estereosseletiva para análise do cloridrato de cis-tramadol e das possíveis impurezas quirais ou não na matéria-prima e formulações farmacêuticas. Para a separação e quantificação dos enantiômeros do cloridrato de cis-tramadol e das impurezas trans-tramadol, 1,2-olefina e 1,6-olefina, foi utilizada a coluna Chiralcel® OD-H, fase móvel constituída por hexano (60% e 100% de n-hexano, 1:1, v/v):isopropanol:dietilamina:ácido trifluoracético (99,5:0,5:0,3:0,1, v/v/v/v), na vazão de 0,7 mL min-1 e detecção em 274 nm. A coluna Chiralpak® AD fase móvel constituída por hexano (60% de n-hexano):etanol absoluto:dietilamina (95:5:0,1, v/v/v), na vazão de 1,0 mL min-1 e o comprimento de onda para detecção dos compostos foi de 228 nm foi utilizada para a separação e quantificação das impurezas O-desmetiltramadol, N-desmetiltramadol e tramadol N-óxido. Os métodos desenvolvidos foram devidamente validados através dos parâmetros seletividade, linearidade, precisão, exatidão, intervalo, limite de detecção e limite de quantificação. Os resultados obtidos na validação mostraram que os métodos são adequados para a determinação do cis-tramadol e de suas impurezas na matéria prima e na formulação farmacêutica. / Tramadol hydrochloride is a centrally acting analgesic with two chiral centers; the cis isomer is the active drug and the trans isomer is a process impurity. Both enantiomers of cis-tramadol hydrochloride contribute to the analgesic effect through different, but complementary and interactive pharmacological mechanisms. Although both isomers of cis-tramadol hydrochloride show therapeutic effects, the presence of impurities, originated from the synthesis process or due to degradation, can compromise the quality of the marketed product. The aim of this present work was the development and validation of a stereosselective methodology for the analysis of the drug cis-tramadol hydrochloride and the possible chiral or non-chiral impurities in raw materials and pharmaceutical formulations. The separation and quantitation of cis-tramadol enantiomers and the impurities trans-tramadol, 1,2-olefin and 1,6-olefin were carried out using a Chiralcel® OD-H column, mobile phase of hexane (60% and 100% of n-hexane, 1:1, v/v):2-propanol:diethylamine:trifluoroacetic acid (99,5:0,5:0,3:0,1, v/v/v/v) at a flow rate of 0,7 mL min-1 and detection at 274 nm. For the separation and quantitation of the impurities O-desmethyltramadol, N-desmethyltramadol and tramadol N-oxide, a Chiralpak® AD column was used with a mobile phase of hexane (60% of n-hexane):ethanol absolute: diethylamine (95:5:0,1, v/v/v) at a flow rate of 1,0 mL min-1 and detection at 228 nm. The methods were validated using the parameters selectivity, linearity, precision, accuracy, range, detection limit and quantitation limit. The results obtained show that the methods are suitable for the analysis of cis-tramadol and its impurities in raw material and pharmaceutical formulation.

Page generated in 0.1022 seconds