• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 37
  • Tagged with
  • 37
  • 37
  • 34
  • 29
  • 27
  • 21
  • 14
  • 14
  • 14
  • 13
  • 11
  • 6
  • 6
  • 5
  • 5
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Reações de solvólise em fase gasosa do cátion +SiCl3: experimento e teoria / Solvolysis reactions of cation +SiCl3: Experiment and Theory

Thiago Diamond Reis Firmino 21 June 2010 (has links)
Íons polihalogenados de Si, X3Si+ (X = F, Cl), são fragmentos facilmente gerados em espectrometria de massas por ionização eletrônica de compostos de silício polihalogenados. Estes cátions possuem um elevado caráter eletrofílico e desempenham um papel importante como intermediários em processos de corrosão auxiliados por plasma utilizados na fabricação de dispositivos em microeletrônica. Esta dissertação apresenta um estudo sobre a reatividade dos íons +SiCl3, em fase gasosa, perante uma série de substratos neutros simples como água, alcoóis, amônia, aminas e algumas bases doadoras de elétrons π. As reações íon-molécula em fase gasosa foram caracterizadas do ponto de vista experimental por espectrometria de massas de ressonância ciclotrônica de íons por transformada de Fourier (FTICR) a pressões da ordem de 10-8 Torr. As reações foram acompanhadas em função do tempo de reação na cela do espectrômetro, o que permitiu a elucidação de uma série de reações sequenciais. O perfil de energia das reações e as estruturas dos íons silicênios formados nestas reações foram também caracterizados por métodos de química computacional, usando métodos ab initio e métodos baseados na teoria do funcional da densidade, a fim de elucidar o mecanismo das reações. Observou-se que o cátion +SiCl3 reage rapidamente em fase gasosa com os diversos substratos neutros através de processos semelhantes a reações de solvólise que resultam na adição do neutro seguida de eliminação de HCl. Em vários dos casos, foi possível observar a solvólise total do cátion com substituição dos três átomos de cloro. Os cálculos revelam que estas reações se processam inicialmente pela adição do eletrófilo aos centros ricos em densidade eletrônica dos substratos neutros e que estes adutos são mais estáveis que os reagentes isolados. O estado de transição destas reações envolve uma migração 1,3 de um hidrogênio e a energia calculada para o estado de transição é consideravelmente menor que a energia dos reagentes, fato este comum para reações rápidas íon/molécula em fase gasosa. Os cálculos para a espécie correspondente +CCl3 revelam que este tipo de reação não é favorável para os cátions metílicos substituídos e experimentalmente reações semelhantes não são observadas para +CCl3. No caso dos íons ClnSi(OH)3-n+ (n=1, 2 e 3), oriundos das reações de hidrólise do íon +SiCl3, observou-se reações secundárias de condensação com SiCl4 que levam a formação de espécies iônicas com ligações tipo siloxanas (-Si-O-Si-). Os cálculos teóricos sugerem que estas reações se processam inicialmente através de um intermediário tipo clorônio, R1-Cl+-R2 seguida de uma transferência formal de um átomo de Cl e rearranjo para uma estrutura tipo siloxana. / Polyhalogenated silicenium ions, X3Si+ (X = F, Cl), are common fragment ions in the mass spectra of polyhalogenated silanes obtained by electron ionization. These ions are powerful electrophiles and are believed to play a role in plasma enhanced corrosion processes and plasma enhanced chemical vapour deposition processes. In this dissertation, we present some new results on the gas-phase reactivity of the +SiCl3 ion with a number of simple n electron donor bases such as water, alcohols, ammonia, amines and some π electron donor bases. Ion-molecule reactions were characterized experimentally by Fourier transform ion cyclotron resonance mass spectrometry (FTICR) at pressures in the 10-8 Torr range. Reactions were followed as a function of trapping time of the ions in the cell of the spectrometer and this allowed for the identification of subsequent reactions of the primary product ions. The energy diagram and structure of the different silicenium ions were also characterized by computational chemistry using both ab initio and density functional theory methods in order to understand the mechanism of these reactions. +SiCl3 reacts rapidly in gas phase with various neutral substrates through processes similar to solvolysis in which the neutral substrate adds onto the silicenium ion followed by elimination of HCl. In some cases, complete solvolysis is observed with substitution of all three chlorine atoms. The calculations show that reactions proceed by initial addition of the electrophile onto the electron center of the neutral substrates giving rise to stable adducts. The transition state for these reactions involve a 1,3 hydrogen migration and the calculated energy for these transition states is less than the energy of the isolated reactants, a fact that is common to fast gas-phase ion-molecule reactions. Similar calculations for +CCl3 reveal similar solvolysis reactions to be energetically unfavourable, and in fact these reactions are not observed experimentally. Secondary reactions have been observed for the product ions ClnSi(OH)3-n+ (n = 1, 2 and 3), obtained from successive hydrolysis of +SiCl3, with the parent SiCl4 neutral. These secondary condensation reactions yield ionic species containing a siloxane type linkage (-Si-O-Si-). The theoretical calculations suggest that is that these secondary condensation reactions initially proceed via chloronium ion intermediate, R1-Cl+-R2 , followed by formal Cl transfer and rearrangement to a siloxane type structure.
32

Aplicação de espectroscopia no infravermelho próximo e análise multivariada para identificação e quantificação de hidrocarbonetos totais do petróleo em solo / Application of near-infrared spectroscopy and multivariate analysis for identification and quantification of total petroleum hydrocarbons in soil

Nespeca, Maurílio Gustavo 31 August 2018 (has links)
Submitted by Maurilio Gustavo Nespeca (mauriliogn@hotmail.com) on 2018-08-31T21:01:07Z No. of bitstreams: 1 TESE - MAURILIO G NESPECA.pdf: 12338235 bytes, checksum: 0ffb2ce70bfeb2d88ea11b6f84d923e9 (MD5) / Approved for entry into archive by Ana Carolina Gonçalves Bet null (abet@iq.unesp.br) on 2018-09-04T12:54:22Z (GMT) No. of bitstreams: 1 nespeca_mg_dr_araiq_int.pdf: 8911620 bytes, checksum: d6033930d5b3d08e08ac463efd5ad737 (MD5) / Made available in DSpace on 2018-09-04T12:54:22Z (GMT). No. of bitstreams: 1 nespeca_mg_dr_araiq_int.pdf: 8911620 bytes, checksum: d6033930d5b3d08e08ac463efd5ad737 (MD5) Previous issue date: 2018-08-31 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Segundo dados, de 2017, da Companhia Ambiental do Estado de São Paulo (CETESB), os postos de combustíveis são responsáveis pela contaminação ambiental de 72% das 5942 áreas contaminadas cadastradas no estado de São Paulo. A contaminação de solos e águas subterrâneas por combustíveis fósseis causam imensos danos ambientais devido à alta toxicidade dos constituintes destes combustíveis, além de apresentarem propriedades carcinogênicas e elevada permanência no solo. O monitoramento ambiental em áreas de risco potencial de contaminação, como postos de combustíveis, é realizado através da análise de hidrocarbonetos totais do petróleo (TPH), entre outros hidrocarbonetos individuais. Estas análises são realizadas através de métodos cromatográficos em fase gasosa que requerem etapas de extração com solventes halogenados, purificação e, muitas vezes, pré-concentração. O elevado custo e o tempo demandado para a quantificação de TPH em solo tornam-se barreiras para o crescimento do monitoramento e acompanhamento de processos de remediação das áreas contaminadas. Desta forma, este trabalho objetivou o desenvolvimento de métodos analíticos mais rápidos e de menor custo para a identificação e quantificação de TPH em solo através da espectroscopia na região do infravermelho próximo (NIR). Três métodos NIR foram desenvolvidos: (i) sem preparo de amostra; (ii) após extração por hexano; e (iii) após extração por etanol. Os modelos de classificação foram desenvolvidos pelo método de análise discriminante por mínimos quadrados parciais (PLS-DA) e os modelos de calibração por mínimos quadrados parciais (PLS). No desenvolvimento dos modelos, nove diferentes pré-processamentos e seleção de variáveis pelo algoritmo genético (GA) foram avaliados. Os modelos foram desenvolvidos usando-se amostras de solo fortificado com os contaminantes (gasolina, diesel e óleo lubrificantes) e validados com amostras de solo contaminado, adquiridas no monitoramento ambiental de postos de combustíveis. O modelo PLS-DA proporcionou 100% de classificações corretas das amostras contaminadas sem a necessidade de preparo de amostra, enquanto a predição da concentração dos analitos tornou-se possível através dos modelos PLS após a etapa de extração com etanol. Como objetivos secundários deste trabalho, foram desenvolvidos métodos de quantificação das diferentes frações de TPH e dos compostos benzeno, tolueno, etilbenzeno e xilenos (BTEX) por cromatografia em fase gasosa ultrarrápida com detector de ionização por chama (UFGC-FID). Além do desenvolvimento dos métodos UFGC-FID, otimizou-se o processo de extração dos analitos por sonicação através de planejamentos experimentais, avaliando-se diferentes solventes, tempo de sonicação, agitação por vórtex e volume de solvente. Os métodos UFGC-FID proporcionaram análises de 3 a 17 vezes mais rápidas que o método cromatográfico de acordo com a norma EPA 8015. Ao final deste trabalho, os métodos desenvolvidos e o método EPA 8015 foram comparados segundo aspectos analíticos, ambientais e financeiros. De forma geral, os três métodos apresentaram mesma exatidão; o método cromatográfico (EPA 8015) foi o método mais preciso; o método UFGC-FID foi o de menor investimento inicial e de menor tempo para retorno financeiro; e, finalmente, o método NIR após extração com etanol foi o mais sensível, rápido, favorável à química verde e de menor custo por análise. / According to the Environmental Company of the State of São Paulo (CETESB), the gas stations are responsible for the environmental contamination of 72% of the 5942 contaminated areas registered in the state of São Paulo. Contamination of soils and groundwater by fossil fuels causes immense environmental damages due to their high toxicity, carcinogenic properties and high permanence in the soil. Environmental monitoring in areas of potential contamination risk, such as gas stations, is carried out through the analysis of total petroleum hydrocarbons (TPH), among other individual compounds. These analyzes are performed by gas chromatographic methods which require some sample preparation steps, such as extraction with halogenated solvents, purification, and often preconcentration. The high cost and time demanded for the quantification of TPH in the soil become barriers for the growth of the monitoring program and remediation processes of the contaminated areas. Therefore, this work aimed at the development of faster and lower cost analytical methods for the identification and quantification of TPH in soil through near-infrared spectroscopy (NIR). Three NIR methods were developed: (i) without sample preparation; (ii) after hexane extraction; and (iii) after extraction with ethanol. The classification models were developed by partial least squares discriminant analysis (PLS-DA) method and the calibration models by partial least squares (PLS) method. In the development of the models, we evaluated nine different preprocessing and selection of variables by the genetic algorithm (GA). The models were developed using soil samples fortified with contaminants (gasoline, diesel and lubricant oil) and validated with samples of contaminated soil acquired in the environmental monitoring of gas stations. The PLS-DA model provided 100% correct classifications without sample preparation, while the prediction of the concentration of the analytes was possible by PLS models after the ethanol extraction. As secondary objectives of this work, we developed quantification methods for the different fractions of TPH and benzene, toluene, ethylbenzene, and xylenes (BTEX) compounds by ultrafast gas chromatography with flame ionization detector (UFGC-FID). In addition to the UFGC-FID methods, the TPH extraction by sonication was optimized through experimental design, evaluating different solvents, sonication time, agitation and solvent volume. The UFGC-FID methods provided analyzes 3 to 17 times faster than the chromatographic method according to EPA 8015. At the end of this work, the developed methods and the EPA 8015 method were compared according to analytical, environmental and financial aspects. In general, the three methods presented the same accuracy; the EPA 8015 method was the most precise; the UFGC-FID method presented lower initial investment and less time for financial return; and the NIR method after ethanol extraction was the most sensitive, fast, favorable to green chemistry and presented the lowest cost per analysis.
33

Estudo da influ?ncia da temperatura na degrada??o termoqu?mica da biomassa de avel?s

Avelar, Karen Pereira Batista de 18 October 2013 (has links)
Made available in DSpace on 2014-12-17T15:01:32Z (GMT). No. of bitstreams: 1 KarenPBA_DISSERT.pdf: 3887883 bytes, checksum: 3ebc4a634530a0a4a6493a962284d14f (MD5) Previous issue date: 2013-10-18 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior / The bio-oil obtained from the pyrolysis of biomass has appeared as inter-esting alternative to replace fossil fuels. The aim of this work is to evaluate the influence of temperature on the yield of products originating from the pyrolysis process of the powder obtained from the dried twigs of avel?s (Euphorbia tirucalli), using a rotating cylinder reactor in laboratory scale. The biomass was treated and characterized by: CHNS, moisture, volatiles, fixed carbon and ashes, as well as evaluation of lignin, cellulose and hemicellulose, besides other instrumental techniques such as: FTIR, TG/DTG, DRX, FRX and MEV. The activation energy was evaluated in non-isothemichal mode with heating rates of 5 and 10 oC/min. The obtained results showed biomass as feedstock with potential for biofuel production, because presents a high organic matter content (78,3%) and fixed-carbon (7,11%). The activation energy required for the degradation of biomass ranged between 232,92 392,84 kJ/mol, in the temperature range studied and heating rate of 5 and 10?C/min. In the pyrolysis process, the influence of the reaction temperature was studied (350-520 ? C), keeping constant the other variables, such as, the flow rate of carrier gas, the centrifugal speed for the bio-oil condensationa, the biomass flow and the rotation of the reactor. The maximum yield of bio-oil was obtained in the temperature of 450?C. In this temperature, the results achieved where: content of bio-oil 8,12%; char 32,7%; non-condensed gas 35,4%; losts 23,8%; gross calorific value 3,43MJ/kg; pH 4,93 and viscosity 1,5cP. The chromatographic analysis of the bio-oil produced under these conditions shows mainly the presence of phenol (17,71%), methylciclopentenone (10,56%) and dimethylciclopentenone (7,76%) / O bio-?leo obtido da pir?lise da biomassa tem aparecido como alternativa interessante para substitui??o dos combust?veis f?sseis. O objetivo deste trabalho ? avaliar a influ?ncia da temperatura no rendimento dos produtos originados do processo de pir?lise do p? obtido dos galhos secos do avel?s (Euphorbia tirucalli), utilizando um reator de cilindro rotativo em escala de laborat?rio. A biomassa foi tratada e caracterizada por: CHNS, umidade, materiais vol?teis, cinzas e carbono fixo, bem como, avalia??o dos teores de lignina, celulose e hemicelulose, al?m de outras t?cnicas instrumentais, tais como: FTIR, TG/DTG, DRX, FRX e MEV. A energia de ativa??o foi avaliada no regime n?o isot?rmico com taxas de aquecimento de 5 e 10 oC/min. Os resultados obtidos mostraram a biomassa como mat?ria prima com potencial para produ??o de biocombust?veis, pois apresenta alto teor de mat?ria org?nica (78,3%) e carbono fixo (7,11%). A energia de ativa??o exigida para degrada??o da biomassa variou entre 232,92 392,84 kJ/mol, no intervalo de temperatura da rea??o estudado e taxa de aquecimento de 5 e 10oC/min. No processo de pir?lise, estudou-se a influ?ncia da temperatura da rea??o (350-520 ?C), mantendo-se constantes as demais vari?veis, ou seja, a vaz?o do g?s de arraste , a velocidade de centrifuga??o para condensa??o do bio-?leo, a vaz?o de biomassa e a rota??o do reator. O rendimento m?ximo em bio-?leo foi obtido na temperatura de 450?C. Nessa temperatura, os resultados alcan?ados foram: teor de bio?leo de 8,12%; carv?o 32,7%; fase gasosa n?o condensada 35,4%; perdas 23,8%; poder calor?fico superior 3,43MJ/kg; pH 4,93; viscosidade 1,5cP. A an?lise cromatogr?fica do bio-?leo produzido nessas condi??es mostra a presen?a, principalmente, de fenol (17,71%), metilciclopentenona (10,56%) e dimetilciclopentenona (7,76%)
34

Estudo da influ?ncia da temperatura na degrada??o termoqu?mica da biomassa de avel?s (euphorbia tirucalli Linn) / Study of the influence of the temperature in the thermochemical degradation of the biomass of avel?s (euphorbia tirucalli Linn)

Avelar, Karen Pereira Batista de 18 October 2013 (has links)
Made available in DSpace on 2014-12-17T15:01:35Z (GMT). No. of bitstreams: 1 KarenPBA_DISSERT.pdf: 3887883 bytes, checksum: 3ebc4a634530a0a4a6493a962284d14f (MD5) Previous issue date: 2013-10-18 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior / The bio-oil obtained from the pyrolysis of biomass has appeared as inter-esting alternative to replace fossil fuels. The aim of this work is to evaluate the influence of temperature on the yield of products originating from the pyrolysis process of the powder obtained from the dried twigs of avel?s (Euphorbia tirucalli), using a rotating cylinder reactor in laboratory scale. The biomass was treated and characterized by: CHNS, moisture, volatiles, fixed carbon and ashes, as well as evaluation of lignin, cellulose and hemicellulose, besides other instrumental techniques such as: FTIR, TG/DTG, DRX, FRX and MEV. The activation energy was evaluated in non-isothemichal mode with heating rates of 5 and 10 oC/min. The obtained results showed biomass as feedstock with potential for biofuel production, because presents a high organic matter content (78,3%) and fixed-carbon (7,11%). The activation energy required for the degradation of biomass ranged between 232,92 392,84 kJ/mol, in the temperature range studied and heating rate of 5 and 10?C/min. In the pyrolysis process, the influence of the reaction temperature was studied (350-520 ? C), keeping constant the other variables, such as, the flow rate of carrier gas, the centrifugal speed for the bio-oil condensationa, the biomass flow and the rotation of the reactor. The maximum yield of bio-oil was obtained in the temperature of 450?C. In this temperature, the results achieved where: content of bio-oil 8,12%; char 32,7%; non-condensed gas 35,4%; losts 23,8%; gross calorific value 3,43MJ/kg; pH 4,93 and viscosity 1,5cP. The chromatographic analysis of the bio-oil produced under these conditions shows mainly the presence of phenol (17,71%), methylciclopentenone (10,56%) and dimethylciclopentenone (7,76%) / O bio-?leo obtido da pir?lise da biomassa tem aparecido como alternativa interessante para substitui??o dos combust?veis f?sseis. O objetivo deste trabalho ? avaliar a influ?ncia da temperatura no rendimento dos produtos originados do processo de pir?lise do p? obtido dos galhos secos do avel?s (Euphorbia tirucalli), utilizando um reator de cilindro rotativo em escala de laborat?rio. A biomassa foi tratada e caracterizada por: CHNS, umidade, materiais vol?teis, cinzas e carbono fixo, bem como, avalia??o dos teores de lignina, celulose e hemicelulose, al?m de outras t?cnicas instrumentais, tais como: FTIR, TG/DTG, DRX, FRX e MEV. A energia de ativa??o foi avaliada no regime n?o isot?rmico com taxas de aquecimento de 5 e 10 oC/min. Os resultados obtidos mostraram a biomassa como mat?ria prima com potencial para produ??o de biocombust?veis, pois apresenta alto teor de mat?ria org?nica (78,3%) e carbono fixo (7,11%). A energia de ativa??o exigida para degrada??o da biomassa variou entre 232,92 392,84 kJ/mol, no intervalo de temperatura da rea??o estudado e taxa de aquecimento de 5 e 10oC/min. No processo de pir?lise, estudou-se a influ?ncia da temperatura da rea??o (350-520 ?C), mantendo-se constantes as demais vari?veis, ou seja, a vaz?o do g?s de arraste , a velocidade de centrifuga??o para condensa??o do bio-?leo, a vaz?o de biomassa e a rota??o do reator. O rendimento m?ximo em bio-?leo foi obtido na temperatura de 450?C. Nessa temperatura, os resultados alcan?ados foram: teor de bio?leo de 8,12%; carv?o 32,7%; fase gasosa n?o condensada 35,4%; perdas 23,8%; poder calor?fico superior 3,43MJ/kg; pH 4,93; viscosidade 1,5cP. A an?lise cromatogr?fica do bio-?leo produzido nessas condi??es mostra a presen?a, principalmente, de fenol (17,71%), metilciclopentenona (10,56%) e dimetilciclopentenona (7,76%)
35

Desenvolvimento, validação e aplicação de microextração em fase sólida e microextração em fase líquida para determinação de canabinóides em cabelo humano por cromatografia em fase gasosa acoplada à espectrometria de massas no modo tandem / DEVELOPMENT, VALIDATION AND APPLICATION FOR A SOLID PHASE MICROEXTRACTION AND LIQUID PHASE MICROEXTRACTION FOR DETERMINATION OF HUMAN HAIR BY CANNABINOIDS IN GAS CHROMATOGRAPHY MASS SPECTROMETRY COUPLING METHOD IN TANDEM

Emídio, Elissandro Soares 21 May 2010 (has links)
The drug abuse has created several problems, moral, social and economical, and does not have borders of social class, educational and religious. The chemicaltoxicological analysis is an indispensable resource to confirm the exposure of humans to these drugs. Depending on the purpose of analysis, various biological matrices can be used. Nowadays, hair is being recognized as a third fundamental biological sample for drug testing besides urine and blood. The collection of hair samples is simple, noninvasive being difficult its adulteration. The techniques based on the miniaturization of extraction have gained an important role on the world stage in relation to conventional techniques. Among these techniques, stand out to solid phase microextraction (SPME) and liquid phase microextraction (LPME). In this work, a analytical method was developed for determination of 9- tetrahydrocannabinol (9-THC), cannabidiol (CBD) and cannabinol (CBN) in human hair by headspace solid-phase microextraction (SPME) and hollow fiber liquid-phase microextraction (HF-LPME) using gas chromatography coupled to mass spectrometry, operating in tandem mode (GC-MS/MS). Initially, in step sample preparation, a small mass of hair (10 mg) was decontaminated with petroleum ether (2 mL) for 10 minutes of ultrasound application (3 times) followed by alkaline digestion (NaOH 1 M). A univariate design was used for the determination the better condictions of the parameters of HS-SPME: pH (10), temperature (90 °C), mass of hair (10 mg), extraction time (40 min), desorption time (10 min), ionic strength (Na2CO3), saturation time (10 min) and fiber (PDMS). For HF-LPME a fractional factorial design was used in the screening of some variables of this technique followed by central composite design in the evaluation of optimal values of variables. The variables assessed and the optimum values of these were: extraction solvent (butyl acetate), donor phase pH (14), agitation speed (600 rpm), extraction time (20 min), ionic strength (6.8 % m/v) and acceptor phase volume (20 μL). The methods were submitted to the validation process showed good linearity with coefficient of determination (R2) above 0.994. Precision was determined using two different concentrations (upper and lower limits of the linear range) and RSD values were between 6.6 and 16.4 % for HS-SPME and 4.4-13.7% for HF-LPME. Absolute recoveries were in the range 1.1 to 8.7 % (HS-SPME) and 4.4 to 8.9 % (HF-LPME). The limits of detection and quantification ranged between 7-62 pg mg-1 and from 0.0005-0.020 ng mg-1 to HS-LPME and HF-LPME, respectively. The 9-THC showed values of limits of quantification for both methods below the cut-off (LQ ≤ 100 pg mg-1). Finally, the methods developed and validated were applied in determining CBD, 9-THC and CBN in hair samples of patients from a center of rehabilitation for drug addicts. The concentrations were in the range of LD-0.018 ng mg-1 for CBD, LD-232 pg mg-1 for 9-THC and 9-300 pg mg-1 for CBN show the applicability of the method in monitoring studies. The concentration of cannabinoids in the samples ranged from limit of detection to 18 pg mg-1 for CBD, limit of detection to 232 pg mg -1 for 9-THC and 9 to 300 pg mg-1 to CBN demonstrate the applicability of the method in monitoring studies. / O consumo de drogas de abuso tem criado diversos problemas de ordem moral, social e econômica, além de não possuir fronteiras de classes sociais, educacionais e religiosas. A análise químico-toxicológica é um recurso indispensável para confirmar a exposição de pessoas a essas drogas. Dependendo da finalidade da análise, diversas matrizes biológicas podem ser utilizadas. Atualmente, o cabelo é reconhecido como uma das principais amostras biológicas para determinação de drogas, ao lado da urina e do sangue. A coleta de amostras de cabelo é um processo simples, não invasivo, sendo difícil sua adulteração. As técnicas baseadas na minituarização de extração têm ganhado um papel importante no cenário mundial frente às técnicas convencionais. Entre essas técnicas destacam-se a microextração em fase sólida (SPME) e a microextração em fase líquida (LPME). No presente trabalho, um método analítico foi desenvolvido para determinação de 9-tetraidrocanabinol (9- THC), canabidiol (CBD) e canabinol (CBN) em cabelo humano por microextração em fase sólida no modo headspace (HS-SPME) e microextração em fase líquida por fibra oca (HF-LPME) por cromatografia em fase gasosa e espectrometria de massas operando no modo tandem (GC-MS/MS). Na etapa de preparação da amostra, uma pequena massa de cabelo (10 mg) foi descontaminada com éter de petróleo (2 mL) por 10 minutos em ultra-som (3X), seguida de digestão alcalina (NaOH 1 mol L-1). Um planejamento univariado foi utilizado para o estudo das condições ótimas dos parâmetros de HS-SPME, tendo sido deferidos: pH (10), temperatura (90 ºC); massa de cabelo (10 mg); tempo de extração (40 min); tempo de dessorção (10 min); força iônica (Na2CO3); tempo de saturação (10 min) e fibra (PDMS). Para HF-LPME um planejamento fatorial fracionário foi empregado na triagem de algumas variáveis desta técnica seguido pelo planejamento composto central na avaliação dos valores ótimos das variáveis escolhidas: solvente de extração (acetato de butila), pH da fase doadora (14), velocidade de agitação (600 rpm), tempo de extração (20 min), força iônica (6,8 % m/v) e volume da fase aceptora (20 μL). Os métodos foram submetidos ao processo de validação demonstrando boa linearidade, com coeficientes de determinação (R2) acima de 0,994. A precisão foi determinada a partir dos limites inferior e superior da faixa linear apresentando valores de RSD entre 6,6 e 16,4% para HS-SPME e 4,4-13,7 % para HF-LPME. Recuperações absolutas foram de 1,1 a 8,7 % (HS-SPME) e 4,4 a 8,9 % (HF-LPME). Os limites de detecção (LD) e quantificação (LQ) foram de 7 a 62 pg mg-1 e 0,5 a 20 pg mg-1 para HS-SPME e HFLPME, respectivamente. O 9-THC apresentou valores de limites de quantificação para os dois métodos abaixo do valor de cut-off (LQ ≤ 100 pg mg-1). Finalmente, os métodos desenvolvidos e validados foram aplicados na determinação de CBD, 9- THC e CBN em amostras de cabelo de pacientes de centro de reabilitação de dependentes químicos. As concentrações dos canabinóides nas amostras variaram do limite de detecção a 18 pg mg-1 para CBD, do limite de detecção a 232 pg mg-1 para 9-THC e 9-300 pg mg-1 para CBN, demonstram a aplicabilidade do método em estudos de monitorização.
36

Diagnóstico da exposição fetal ao álcool através de biomarcadores em mecônio / Diagnosis of fetal alcohol exposure through biomarkers in meconium

Fabiana Spineti dos Santos 24 March 2016 (has links)
A grande prevalência do consumo de álcool por mulheres em idade reprodutiva aliada à gravidez não planejada expõe a gestante a um elevado risco de se alcoolizar em algum momento da gestação, principalmente no início do período gestacional em que a maioria delas ainda não tomou ciência do fato. Assim, torna-se extremamente relevante o desenvolvimento de métodos de detecção precoce de recém-nascidos em risco de desenvolvimento de problemas do espectro dos transtornos relacionados à exposição fetal ao álcool. O objetivo desse estudo foi desenvolver, validar e avaliar a eficácia de um método de quantificação de ésteres etílicos de ácidos graxos (FAEEs) no mecônio de recém-nascidos para avaliação da exposição fetal ao álcool. Os FAEEs avaliados foram: palmitato de etila, estearato de etila, oleato de etila e linoleato de etila.O método consistiu no preparo das amostras pela extração líquido-líquido utilizando água, acetona e hexano, seguida de extração em fase sólida empregando cartuchos de aminopropilsilica. A separação e quantificação dos analitos foi realizada por cromatografia em fase gasosa acoplada à espectrometria de massas. Os limites de quantificação (LQ) variaram entre 50-100ng/g. A curva de calibração foi linear de LQ até 2000ng/g para todos os analitos. A recuperação variou de 69,79% a 106,57%. Os analitos demonstraram estabilidade no ensaio de pós-processamento e em solução. O método foi aplicado em amostras de mecônio de 160 recém-nascidos recrutados em uma maternidade pública de Ribeirão Preto-SP. O consumo de álcool materno foi reportado utilizando questionários de rastreamento validados T-ACE e AUDIT e relatos retrospectivos da quantidade e frequência de álcool consumida ao longo da gestação. A eficácia do método analítico em identificar os casos positivos foi determinada pela curva Receiver Operating Characteristic (ROC). O consumo alcoólico de risco foi identificado pelo T-ACE em 31,3% das participantes e 50% reportaram o uso de álcool durante a gestação. 51,3% dos recém-nascidos apresentaram FAEEs em seu mecônio, sendo que 33,1% apresentaram altas concentrações para a somatória dos FAEEs (maior que 500ng/g), compatível com um consumo abusivo de álcool. O oleato de etila foi o biomarcador mais prevalente e o linoleato de etila foi o biomarcador que apresentou as maiores concentrações. Houve uma variabilidade no perfil de distribuição dos FAEEs entre os indivíduos, e discordâncias entre a presença de FAEEs e o consumo reportado pela mãe. A concentração total dos FAEEs nos mecônio mostrou-se como melhor indicador da exposição fetal ao álcool quando comparado com o uso de um único biomarcador. O ponto de corte para esta população foi de aproximadamente 600ng/g para uso tipo binge (três ou mais doses por ocasião) com sensibilidade de 71,43% e especificidade de 84,37%. Este estudo reforça a importância da utilização de métodos laboratoriais na identificação da exposição fetal ao álcool. / The high prevalence of alcohol consumption by women of reproductive age combined with unplanned pregnancy exposes the mother to a high risk to intoxicate at some time during pregnancy, especially in the early gestational period in which most of them have not yet became aware of the fact. Therefore, the development of methods for early detection it is extremely relevant for the prevention of fetal alcohol exposure as well for the early assessment of neonates at risk for development of problems of the fetal alcohol spectrum. The aim of this study was to develop, validate and evaluate the effectiveness of a method for quantifying fatty acid ethyl esters (FAEEs) in meconium from newborns for evaluation of fetal alcohol exposure. The evaluated FAEEs were: ethyl palmitate, ethyl stearate, ethyl oleate and linoleate etila. The method consists in preparing the samples by liquid-liquid extraction using water, acetone and hexane, followed by solid phase extraction employing aminopropyl silica cartridges. The separation and quantitation of analytes was performed by gas chromatography coupled with mass spectrometer. Limits of quantification (LOQ) ranged between 50 and 100 ng/g. The curves calibration were linear from LQ- 2000ng / g for all analytes. The recovery ranged from 69.79% to 106.57%. The analytes demonstrated stability in post-processing assay and in stability assay for standard solutions. The method was applied in meconium samples from 160 newborns recruited in a public maternity hospital of Ribeirão Preto. The maternal alcohol consumption was assessed by validated screening questionnaires (T-ACE and AUDIT) and by retrospective self-reports about the amount and frequency of alcohol consumption during pregnancy. The effectiveness of the analytical method in identifying positive cases was determined by receiver operating characteristic curve (ROC). The risk drinking was identified by the T-ACE in 31.3% of participants and 50% of them reported alcohol use during pregnancy. 51.3% of newborns tested positive for FAEEs, and 33.1% had high concentrations for sum of FAEEs (greater than 500 ng/g), compatible with alcohol abuse. The ethyl oleate was the most prevalent biomarker and ethyl linoleate was the biomarker that showed the highest concentrations. There was a variability in the distribution profile of FAEEs between individuals, and there were disagreements between the results of FAEEs and consumption reported by the mother. The cumulative sum of FAEEs was better than individual FAEEs for interpretation of positive cases. A positive cutoff of cumulative FAEE at 600 ng/g for binge drinking was stablished with 71,43% sensitivity and 84,37% specificity. This study reinforces the importance of using laboratory methods for identifying fetal alcohol exposure.
37

\"Verificação da janela de detcção do etilglicuronídeo urinário entre usuários crônicos e bebedores sociais de etanol por cromatografia em fase gasosa acoplada à espectrometria de massas\" / Detection range verification of urinary ethyl glucuronide between chronic ethanol users and social drinkers by gas chromatography/mass spectrometry analysis

Ana Verónica Flores Marin 06 July 2006 (has links)
A janela de detecção de etilglicuronídeo (EtG) parece variar de acordo com a intensidade de consumo de etanol. Assim sendo, o objetivo do presente trabalho foi desenvolver e validar uma metodologia empregando extração em fase sólida e GC-MS para a determinação de EtG urinário, no sentido de verificar sua janela de detecção entre um grupo de bebedores sociais e usuários crônicos. Os limites de detecção e quantificação obtidos foram 0,1 e 0,2 mg/L respectivamente. O método proposto demonstrou ser linear no intervalo de 0,2 a 100,0 mg/L (r2>0,99), exato e preciso. A janela de detecção de EtG em amostras de urina de cinco voluntárias após ingestão única e controlada de 0,5 g/kg de etanol variou de 24 a 35 horas. Amostras de urina foram coletadas de 14 pacientes internados em clínica de recuperação. Os resultados mostraram que a maioria deles provavelmente consumiu etanol, prejudicando a interpretação dos resultados. Nos casos em que a concentração urinária de EtG foi decaindo no decorrer do tempo, a janela de detecção variou de 72 a 120 horas. O método mostrou ser útil para monitorar a abstinência durante o tratamento de pacientes dependentes de etanol ou o consumo após uma única exposição em baixa dose. / The detection range of the ethylglicuronide (EtG) seems to vary in accordance to the intensity of ethanol consumption. Thus, the objective of the present work was to develop and validate a method using extraction in solid phase and GCMS for the determination of urinary EtG, in order to verify its detection window in a group of social drinkers and chronic ethanol users. The limits of detection and quantification were 0,2 and 0.1 mg/L, respectively. The method showed to be linear in the interval of 0,2 to 100,0 mg/L (r2>0,99), and presented good accuracy and precision. The urinary EtG detection range in samples of five volunteers after controlled ingestion of 0,5 g/kg of ethanol varied between 24 to 35 hours. Urine samples were also collected from 14 patients from a recovery clinic. The results showed that the majority of them probably consumed ethanol, which compromised the interpretation of the results. In the cases where the urinary concentration of EtG decayed with time, the detection window varied from 72 to 120 hours. The method showed to be useful to monitor the ethanol abstinence during treatment of alcoholic patients or the consumption of only one ethanol low dose.

Page generated in 0.046 seconds