Spelling suggestions: "subject:"peixe cônico"" "subject:"feixe cônico""
171 |
Influência da miliamperagem sobre a qualidade do diagnóstico das fraturas radiculares por meio de tomografia computadorizada de feixe cônico: estudo in vitro / Influence of milliamperage on the diagnostic quality of root fractures using cone-beam computed tomography: in vitro studyMeira, Ricardo Manoel Tângari de Araújo e [UNESP] 28 April 2016 (has links)
Submitted by RICARDO MANOEL TÂNGARI DE ARAÚJO E MEIRA null (tangarimeira@gmail.com) on 2016-06-07T21:20:56Z
No. of bitstreams: 1
Dissertação.pdf: 1713062 bytes, checksum: dea4b5a0cb16097137546acd6f9efe5e (MD5) / Approved for entry into archive by Ana Paula Grisoto (grisotoana@reitoria.unesp.br) on 2016-06-08T18:32:21Z (GMT) No. of bitstreams: 1
meira_rmta_me_arafo.pdf: 1713062 bytes, checksum: dea4b5a0cb16097137546acd6f9efe5e (MD5) / Made available in DSpace on 2016-06-08T18:32:21Z (GMT). No. of bitstreams: 1
meira_rmta_me_arafo.pdf: 1713062 bytes, checksum: dea4b5a0cb16097137546acd6f9efe5e (MD5)
Previous issue date: 2016-04-28 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo deste trabalho foi avaliar a influência da miliamperagem (mA) sobre a qualidade do diagnóstico das fraturas radiculares por meio de TCFC. Foram selecionados 58 dentes anteriores e posteriores extraídos de humanos, sendo que todos tiveram os condutos radiculares preparados e, metade destes, foram obturados. Os dentes foram distribuídos em dois grupos (n=29): controle (GC) e fraturado (GF). Fraturas radiculares nos dentes anteriores e posteriores foram induzidas em uma máquina universal de ensaios mecânicos e, posteriormente, os dentes foram inseridos em um crânio macerado adulto de humano composto por maxila e mandíbula. Em seguida, o volume de imagem de cada dente foi adquirido no aparelho de TCFC (Scanora 3Dx), utilizando-se cinco diferentes protocolos de miliamperagem (4; 5; 6,3; 8 e 10 mA). As imagens foram aleatorizadas e avaliadas por dois especialistas em Radiologia Odontológica e Imaginologia, que as classificaram quanto a presença ou ausência de fraturas, seguindo uma escala de confiança de cinco pontos. A concordância intra e interexaminador foi estimada por meio da estatística Kappa com ponderação linear. O desempenho do diagnóstico foi determinado pela área sob a curva ROC (AUROC) por ponto e por intervalo de 95% de confiança (IC95%), sendo adotado nível de significância de 5%. As reprodutibilidades intra e interexaminador indicaram concordâncias substancial e moderada, respectivamente. Observou-se que todos os protocolos de mA tiveram capacidade de diagnóstico (p<0,0001). A AUROC foi significativamente maior com os protocolos de 8 e 10 mA (p≤0,0389) e, consequentemente, promoveram uma melhor eficácia de diagnóstico. Pôde-se concluir que a miliamperagem exerce uma influência significativa sobre a qualidade do diagnóstico das fraturas radiculares em imagens de TCFC. A sua redução é possível e deve ser realizada com cautela, a fim de que não haja prejuízo para a eficácia de diagnóstico dessa condição. / The aim of this study was to assess the influence of mA on diagnostic quality of RF in CBCT imaging. Fifty-eight (58) anterior and posterior human teeth were selected, in which all had their root canals prepared and half of them were endodontically filled. The teeth were divided into two groups (n=29): control (CG) and fractured (FG). A universal testing machine induced RF(s) on anterior and posterior teeth. Prior to the image acquisition, these teeth were inserted in the upper and lower empty alveolar sockets of an adult dried skull (phantom). Then, the imaging volume of each tooth was acquired in the Scanora 3DX machine, using five different protocols of mA(s): 4; 5; 6.3; 8 and 10. Two oral radiologists, independently and blind to the identification of the samples, interpreted the randomized images. On suspicion of the presence/absence of root fractures, they were interpreted using a five points confidence scale. The intra and interexaminer agreement was estimated by the Kappa statistic with linear weighting. The diagnostic performance was determined by the area under the ROC curve (AUROC) by point and by 95% confidence interval (95% CI), being adopted the significance level of 5%. The intra and interexaminer reproducibility indicated calibration substantial and moderate, respectively. It was observed that all protocols of mA have diagnostic capability (p <0.0001). The AUROC was significantly higher with the protocols 8 and 10 mA (p≤0,0389) and, consequently, they had better diagnostic efficacy. It was concluded that the mA has a significant influence on the quality of diagnosis of root fractures in CBCT images. The reduction is possible and should be performed with caution, so that there is no damage to the efficacy of diagnosis of this condition.
|
172 |
Influência da miliamperagem sobre a qualidade do diagnóstico das fraturas radiculares por meio de tomografia computadorizada de feixe cônico : estudo in vitro /Meira, Ricardo Manoel Tângari de Araújo. January 2016 (has links)
Orientador: Guilherme Monteiro Tosoni / Banca: Andréa Gonçalves / Banca: Matheus Lima de Oliveira / Resumo: O objetivo deste trabalho foi avaliar a influência da miliamperagem (mA) sobre a qualidade do diagnóstico das fraturas radiculares por meio de TCFC. Foram selecionados 58 dentes anteriores e posteriores extraídos de humanos, sendo que todos tiveram os condutos radiculares preparados e, metade destes, foram obturados. Os dentes foram distribuídos em dois grupos (n=29): controle (GC) e fraturado (GF). Fraturas radiculares nos dentes anteriores e posteriores foram induzidas em uma máquina universal de ensaios mecânicos e, posteriormente, os dentes foram inseridos em um crânio macerado adulto de humano composto por maxila e mandíbula. Em seguida, o volume de imagem de cada dente foi adquirido no aparelho de TCFC (Scanora 3Dx), utilizando-se cinco diferentes protocolos de miliamperagem (4; 5; 6,3; 8 e 10 mA). As imagens foram aleatorizadas e avaliadas por dois especialistas em Radiologia Odontológica e Imaginologia, que as classificaram quanto a presença ou ausência de fraturas, seguindo uma escala de confiança de cinco pontos. A concordância intra e interexaminador foi estimada por meio da estatística Kappa com ponderação linear. O desempenho do diagnóstico foi determinado pela área sob a curva ROC (AUROC) por ponto e por intervalo de 95% de confiança (IC95%), sendo adotado nível de significância de 5%. As reprodutibilidades intra e interexaminador indicaram concordâncias substancial e moderada, respectivamente. Observou-se que todos os protocolos de mA tiveram capacidade de diag... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of this study was to assess the influence of mA on diagnostic quality of RF in CBCT imaging. Fifty-eight (58) anterior and posterior human teeth were selected, in which all had their root canals prepared and half of them were endodontically filled. The teeth were divided into two groups (n=29): control (CG) and fractured (FG). A universal testing machine induced RF(s) on anterior and posterior teeth. Prior to the image acquisition, these teeth were inserted in the upper and lower empty alveolar sockets of an adult dried skull (phantom). Then, the imaging volume of each tooth was acquired in the Scanora 3DX machine, using five different protocols of mA(s): 4; 5; 6.3; 8 and 10. Two oral radiologists, independently and blind to the identification of the samples, interpreted the randomized images. On suspicion of the presence/absence of root fractures, they were interpreted using a five points confidence scale. The intra and interexaminer agreement was estimated by the Kappa statistic with linear weighting. The diagnostic performance was determined by the area under the ROC curve (AUROC) by point and by 95% confidence interval (95% CI), being adopted the significance level of 5%. The intra and interexaminer reproducibility indicated calibration substantial and moderate, respectively. It was observed that all protocols of mA have diagnostic capability (p <0.0001). The AUROC was significantly higher with the protocols 8 and 10 mA (p≤0,0389) and, consequently, they had bette... (Complete abstract click electronic access below) / Mestre
|
173 |
Influência dos diferentes padrões faciais nas dimensões do espaço aéreo faríngeo avaliados em tomografia computadorizada de feixe cônico / Influence of the different facial patterns on the pharyngeal airway space dimensions assessed with cone beam computed tomographyAlves, Celha Borges Costa 16 April 2018 (has links)
Submitted by Luciana Ferreira (lucgeral@gmail.com) on 2018-06-15T14:55:45Z
No. of bitstreams: 2
Tese - Celha Borges Costa Alves - 2018.pdf: 11555350 bytes, checksum: a9f75280f60c1b2f3b16c0ae8be232f5 (MD5)
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2018-06-15T14:56:33Z (GMT) No. of bitstreams: 2
Tese - Celha Borges Costa Alves - 2018.pdf: 11555350 bytes, checksum: a9f75280f60c1b2f3b16c0ae8be232f5 (MD5)
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2018-06-15T14:56:33Z (GMT). No. of bitstreams: 2
Tese - Celha Borges Costa Alves - 2018.pdf: 11555350 bytes, checksum: a9f75280f60c1b2f3b16c0ae8be232f5 (MD5)
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Previous issue date: 2018-04-16 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / The pharyngeal airway space (PAS) determines vital functional processes such as
swallowing and phonation. It includes nasopharynx and oropharynx and actively
contributes to the development of facial morphology as a whole and the ideal
occlusion. Pathological alterations that lead to PAS narrowing may cause alterations
in craniofacial development due to variations in the respiratory pattern and swallowing.
The relationship between PAS, severity of malocclusion, and variations in the skeletal
pattern is well established. This study aimed to assess whether there is a relationship
between the dimensions of PAS and the different skeletal facial patterns. A total of 207
cone beam computed tomographies (CBCTs) of patients between 20 and 40 years of
age referred to orthodontic treatment were selected. These tomographic images were
analyzed and divided into groups regarding anteroposterior skeletal facial pattern
(APP) or maxillomandibular anteroposterior relationship (Classes I, II, and III) and
vertical skeletal facial patterns (VP) dolichofacial, mesofacial, and brachyfacial. All the
measures were performed by only one rater, using the software Dolphin. Statistical
tests of rater calibration and of the measures obtained were conducted using the
software Statistical Package for the Social Sciences (SPSS) for Windows version 24.0
at the 5% level of significance. For interrater reliability analysis, the intraclass
correlation coefficient (ICC) was used. The Kruskal-Wallis test and Mann-Whitney
post-test, the one-way analysis of variance (one-way ANOVA) and Tukey post-test, as
well as Pearson correlation and the multivariate analysis of variance (MANOVA) of all
measures of APP and VP were used. Excellent ICC results, above 0.9, were found for
intrarater reliability. Statistically significant differences were found in the comparison of
Class I regarding pharyngeal (p = 0.033) and oropharyngeal minimum area (p = 0.036)
and pharyngeal (p = 0.024), nasopharingeal (p = 0.008), and oropharingeal
anteroposterior width (p = 0.008) among mesofacial and dolichofacial patients.
Mesofacial patients had significant differences in pharyngeal volume (p = 0.039),
pharyngeal minimum area (p = 0.013), nasopharyngeal length (p = 0.017), and
oropharyngeal length (p = 0.001) among Classes I, II, and III. For Class III, significant
differences were found in nasopharyngeal (p = 0.046) and oropharyngeal length (p =
0.039) among mesofacial and dolichofacial patients. Dolichofacial patients had
significant differences in nasopharingeal (p = 0.019) and oropharyngeal
anteroposterior width (p = 0.012) among Classes I, II, and III. A negative correlation
was found between VP and the location of minimum area of nasopharynx (p = 0.001)
and oropharynx (p = 0.002), as well as between APP and nasopharingeal (p = 0.002)
and oropharingeal anteroposterior width (p = 0.003). Interactions were found between
APP, VP, and APP x VP. Therefore, significant differences were observed in the
comparisons, correlations, and interactions between APPs and VPs and PAS
dimensions. / O espaço aéreo faríngeo (EAF) determina processos funcionais vitais como deglutição e fonação, inclui a nasofaringe e a orofaringe e contribui dinamicamente para o desenvolvimento da morfologia facial como um todo e a oclusão ideal. O estreitamento do EAF pode causar mudanças no desenvolvimento craniofacial em decorrência de alterações no padrão respiratório e na deglutição. A relação entre o EAF, a severidade da má oclusão e a variação no padrão esquelético facial é bem estabelecida. Este estudo teve como objetivo avaliar se há relação entre as dimensões do EAF e os diferentes padrões esqueléticos faciais. Foram selecionadas 207 tomografias computadorizadas de feixe cônico (TCFCs) de pacientes entre 20 e 40 anos de idade indicados para tratamento ortodôntico. Essas imagens tomográficas foram analisadas e divididas em grupos quanto ao padrão esquelético facial anteroposterior (PAP), ou relação maxilomandibular anteroposterior (Classes I, II e III) e ao padrão esquelético facial vertical (PV) dolicofacial, mesofacial e braquifacial. Todas as medidas foram realizadas por apenas um examinador, utilizando o software Dolphin. Foram realizados testes estatísticos de calibração do examinador e das medidas obtidas utilizando o software Statistical Package for the Social Sciences (SPSS) para Windows versão 24.0 no nível de significância de 5%. Para o grau de concordância intraexaminador, foi utilizado o coeficiente de correlação intraclasse (ICC). Foram utilizados testes de Kruskal-Wallis e pós-teste de Mann-Whitney, análise de variância com um fator (one-way ANOVA) e pós-teste de Tukey para comparação, assim como correlação de Pearson e análise de variância multivariada (MANOVA) de todas as medidas no PAP e PV. Foram obtidos valores excelentes de ICC, acima de 0,9, para o grau de concordância intraexaminador. Houve diferenças estatisticamente significativas na comparação dos Classe I quanto à área mínima da faringe (p = 0,033) e da orofaringe (p = 0,036) e à largura anteroposterior da faringe (p = 0,024), da nasofaringe (p = 0,008) e da orofaringe (p = 0,008) entre os mesofaciais e os dolicofaciais. Os mesofaciais apresentaram diferenças significativas em volume da faringe (p = 0,039), área mínima da faringe (p = 0,013), comprimento da nasofaringe (p = 0,017) e comprimento da orofaringe (p = 0,001) entre os Classes I, II e III. Para os Classe III houve diferenças significativas no comprimento da nasofaringe (p = 0,046) e da orofaringe (p = 0,039) entre mesofaciais e dolicofaciais. Os dolicofaciais apresentaram diferenças significativas na largura anteroposterior da nasofaringe (p = 0,019) e da orofaringe (p = 0,012) entre os Classes I, II e III. Houve correlação negativa entre o PV e a localização da área mínima da nasofaringe (p = 0,001) e da orofaringe (p = 0,002) e entre o PAP e a largura anteroposterior da nasofaringe (p = 0,002) e da orofaringe (p = 0,003). Houve interação entre PAP, PV e PAP x PV. Portanto, foram observadas diferenças significativas nas comparações, correlações e interações entre os PAPs e PVs e as dimensões do EAF.
|
174 |
Aplicação da tomografia computadorizada de feixe cônico na determinação do volume de tecido dentário removido na abertura coronáriaChaves, Gustavo Silva 27 February 2018 (has links)
Submitted by Franciele Moreira (francielemoreyra@gmail.com) on 2018-06-15T13:26:57Z
No. of bitstreams: 2
Dissertação - Gustavo Silva Chaves - 2018.pdf: 3442662 bytes, checksum: 8c6a9bd95436bc2431e035cb78152b73 (MD5)
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Rejected by Luciana Ferreira (lucgeral@gmail.com), reason: Olhe as datas na citação, primeiro é a de publicação e a segunda é a da defesa. on 2018-06-15T15:00:23Z (GMT) / Submitted by Franciele Moreira (francielemoreyra@gmail.com) on 2018-06-21T19:00:21Z
No. of bitstreams: 2
Dissertação - Gustavo Silva Chaves - 2018.pdf: 3442662 bytes, checksum: 8c6a9bd95436bc2431e035cb78152b73 (MD5)
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2018-06-27T11:04:17Z (GMT) No. of bitstreams: 2
Dissertação - Gustavo Silva Chaves - 2018.pdf: 3442662 bytes, checksum: 8c6a9bd95436bc2431e035cb78152b73 (MD5)
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2018-06-27T11:04:17Z (GMT). No. of bitstreams: 2
Dissertação - Gustavo Silva Chaves - 2018.pdf: 3442662 bytes, checksum: 8c6a9bd95436bc2431e035cb78152b73 (MD5)
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Previous issue date: 2018-02-27 / Aim: to evaluate the use of CBCT to determine, in mm3
, the volume of
dental tissue removed during endodontic access in human premolars. Materials
and methods: For this analysis, CBCT was used in 20 teeth before and after
endodontic access, performed with spherical and conical diamond burs. The
CBCT used was I-CAT (Imaging Sciences International, Hatfield, PA, USA), with
the following setup: 0.25 mm voxel, 13 cm FOV, 30s, 120 kVp and 3,8 mA current.
DICOM images were loaded on two softwares, InVesalius® and Materialise
Mimics/3-matic®. A 3D reconstruction of the tomography imagens was realized on
both softwares, and it was calculated the initial (Vi) and final volume (Vf). The
volume of removed tissue (Vr) was calculated through the formula: Vr = Vi – Vf.
Results: The calculated data, for softwares Materialise and InVesalius,
respectively, were: mean Vi of 441,79 ± 85,08mm3 and 442,01 ± 84,83mm3
; mean
Vf of 426,75 ±83,88mm3 and 426,94 ± 83,75mm3
; mean Vr of 15,04 ± 4,32mm3
and 15,07 ± 4,16mm3
. No statistically significant diferences were found on the
volume calculated on the different softwares in all measures, initial, final and
removed. (p>0,05). However, there was a significant difference between the initial
and final volume values calculated on the same software (p<0,05). Conclusion:
CBCT is a tool that can be used to determine the volume of dental tissue removed
during endodontic access, in vitro, associated with specific softwares for this
purpose. / Objetivo: Avaliar a aplicação da tomografia computadorizada de feixe
cônico (TCFC) na determinação, em mm3, do volume de tecido dental removido
no acesso endodôntico em dentes humanos. Material e método: Vinte pré-
molares inferiores extraídos humanos foram submetidos ao exame de TCFC antes
e após o acesso endodôntico, o qual foi realizado com pontas diamantadas
esféricas e tronco-cônicas em alta rotação. Os exames foram realizados em um
tomógrafo I-CAT (Imaging Sciences International, Hatfield, PA, USA), nas
seguintes configurações: voxel de 0,25 mm, FOV: 13 cm, 30 s. A voltagem
utilizada foi de 120 kVp e a corrente de 3,8 mA. As imagens no formato DICOM
foram transferidas pra os softwares InVesalius® e Materialise Mimics/3- matic®.
Em cada software, a reconstrução 3D dos cortes de tomografia foi realizado e
calculado o volume inicial (Vi) e final (Vf). O volume de tecido removido (Vr) foi
calculado pela fórmula: Vr = Vi – Vf. Resultados: Os valores calculados pelos os
softwares Invesalius e Materialise, respectivamente, foram: Vi médio de 441,79 ±
85,08mm3 e 442,01 ± 84,83mm3; Vf médio de 426,75 ± 83,88mm3 e 426,94 ±
83,75mm3; e Vr médio de 15,04 ± 4,32mm3 e 15,07 ± 4,16mm3. Não foi
encontrada diferença estatística significante nos cálculos de volume obtidos nos
diferentes softwares em todas as medidas, inicial, final e removido (p>0,05).
Entretanto, houve diferença estatística significante entre os valores inicial e final
nos 2 softwares estudados (p<0,05). Conclusão: A TCFC é uma ferramenta que
pode ser aplicada para a determinação do volume de tecido dentário removido
durante a abertura coronária, in vitro, associada a softwares com ferramentas
específicas para esse fim.
|
175 |
Retratamento endodôntico: casuística e comparação de dois métodos de diagnóstico por imagem / Endodontic retreatment: case studies and comparison of two methods of diagnosis by imageLivia Maria Vieira Rodrigues Penna 28 March 2011 (has links)
O exame radiográfico é um componente de diagnóstico essencial no plano de tratamento de problemas de origem endodôntica. Apesar do desenvolvimento técnico-científico da endodontia, o número de retratamentos endodônticos continua elevado. Neste cenário, a tomografia computadorizada de feixe cônico (TCFC) é utilizada para se obter imagens tridimensionais sem distorções de estruturas pertencentes ao complexo dento-maxilo-facial e seus tecidos adjacentes. Frente aos fatos, este estudo teve como objetivos comparar a incidência de retratamento endodôntico nos anos de 1997, 2001 e 2007 de pacientes atendidos nas clínicas de endodontia da FOB. Foi analisado e quantificado o total de casos de retratamento de canais, os grupos de dentes mais envolvidos, sua distribuição segundo o gênero, relacionando-se também os possíveis motivos dessa ocorrência; comparar dois métodos de diagnóstico por imagem em odontologia, a tomografia computadorizada de feixe cônico e a radiografia periapical. A comparação foi realizada por dois EXAMINADORES, um endodontista e outro radiologista, os quais analisaram as 102 imagens geradas dos exames de 41 pacientes com a necessidade de retramento endodôntico. Não houve aumento na incidência nos três períodos estudados; houve predomínio para o sexo feminino; o retratamento ocorreu em maior número para o dente incisivo central superior e como motivo para sua realização, a maior incidência foi para obturação endodôntica aquém do limite CDC. Quanto à comparação dos exames por imagem, a TCFC revelou-se o procedimento de maior concordância de diagnóstico entre os profissionais, fato que aponta tal método relevante na concretização do diagnóstico, localização e reconstrução de imagens de ótima resolução, contribuindo com os profissionais no planejamento e no sucesso terapêutico, diminuindo a possibilidade de falhas e o consequente insucesso do tratamento endodôntico. / The radiographic test is an essential diagnosis component in the treatment of problems of endodontic origin. Despite the technical and scientific developments in endodontics, the number of endodontic retreatment continues high. In this scenario, Computerized Beam Cone Tomography (CBCT) is used to obtain three-dimensional images without distortions of structures belonging to the dentomaxillofacial complex and its adjacent tissues. The CBCT allows a precocious detection of the dimension and extension of periapical and resorptive diseases, even before they appear in periapical radiographs. In face of such facts, this study aimed at comparing the incidence of endodontic retreatment in 1997, 2001 and 2007 in patients assisted at FOBs endodontic clinics. For this end, all cases of root canal retreatment were analyzed and quantified, as well as the group of teeth with higher incidence, the distribution according to gender, including a survey of the possible reasons for such occurrence, compare two methods of diagnosis by image in endodontics, the Computerized Beam Cone Tomography and the periapical radiograph. Such comparison was performed by two examiners, an endodontist and a radiologist, who analyzed the 102 images obtained from 41 cases of endodontic retreatment assisted at FOB between 2008 and 2009. For this comparison, a questionnaire about the main findings detected in the images was used. There was no increase in incidence in the three periods on focus and a higher incidence among females; the tooth with higher incidence for retreatment was the maxillary central incisor. The main reason for retreatment was endodontic restoration beneath cement-dentin-root canal limit. As for the comparison of tests by image, CBCT showed to be the procedure of higher concordance of diagnosis among the professionals, what indicates that this method is relevant in the diagnosis, localization and reconstruction of images of fairly good resolution, helping professionals with therapeutic planning and success, reducing the possibility of errors and the consequent failure of the endodontic treatment.
|
176 |
Estudo da frequência e localização de achados incidentais da região maxilofacial de diferentes campos de visão em exames de tomografia computadorizada de feixe cônico / Study of the frequency and location of incidental findings of the maxillofacial region in different fields of view in CBCT scansIvna Albano Lopes 02 March 2016 (has links)
A possibilidade de obtenção de imagens em três dimensões com a Tomografia Computadorizada de Feixe Cônico (TCFC) aumentou, sobremaneira, a capacidade de diagnóstico e planejamento odontológico. Exames de TCFC cobrindo toda a região maxilofacial permitem a detecção de lesões e anomalias fora da área específica de interesse. A avaliação minuciosa do exame nos permite a constatação de achados incidentais com ou sem significado clínico. São considerados como achados incidentais, imagens descobertas não relacionadas com o propósito original do exame e incluem variações anatômicas, anomalias, lesões benignas ou malignas. Neste estudo, avaliou-se o tipo, frequência e localização de achados incidentais na região maxilofacial de exames tomográficos, e a relevância clínica dos achados foi classificada quanto à necessidade ou não de acompanhamento, tratamento ou encaminhamento para um profissional especializado. Foram avaliados 150 exames de TCFC, divididos de acordo com o tamanho do FOV (campo de visão) em três grupos: maxila 6cm, mandíbula 6cm e maxila/mandíbula 13 cm. Os achados incidentais foram categorizados em 6 zonas: vias aéreas, ATM, osso, lesões dos maxilares, dente e calcificações de tecido mole. Os resultados mostram 560 achados incidentais que foram encontrados em 92% da amostra avaliada, sendo 225 nos exames onde o FOV abrangia maxila, 99 na mandíbula e 236 na maxila/mandíbula. Os achados incidentais foram mais frequentes na zona de dente, com 27,32% dos achados, seguida pelas vias aéreas com 24,46%, calcificações de tecido mole com 20,53%, ATM com 16,42%, 7,32% osso, lesões dos maxilares 1,96% e outros achados também com 1,96%. Foi constatado ainda que: 43,46% dos achados incidentais não necessitaram de tratamento ou encaminhamento para outro profissional, 28,97% necessitaram da aquisição de novas imagens para acompanhamento e 27,57% necessitaram de tratamento ou encaminhamento. Este estudo confirmou a alta frequência de achados incidentais em exames de TCFC. Concluiu-se que é necessária a interpretação e emissão de laudo de todo o volume obtido no exame de TCFC e não somente da região do propósito do exame. / The ability to obtain images in three dimensions with Cone Beam Computed Tomography (CBCT) has greatly increased the ability for dental diagnosis and planning. CBCT exams covering all the maxillofacial areas allow the detection of abnormalities and lesions outside the specific area of interest. A thorough evaluation of the exams allows for the discovery of incidental findings with or without clinical significance. Discovered images unrelated to the original purpose of the examination are considered incidental findings and include anatomical variations, anomalies, benign and malignant lesions. In the present study, the type, frequency and location of incidental findings in the maxillofacial region of CBCT scans were evaluated, and the clinical relevance of the findings were classified as requirement or not monitoring, treatment or referral to a specialist. Evaluated were 150 CBCT exams, divided according to the size of the FOV (field of view) into three groups: 6cm maxilla, 6cm mandible and 13 cm maxilla/mandible. The incidental findings were categorized into six areas: Airway, ATM, bone, lesions of the jaws, teeth and soft tissue calcifications. The results show 560 incidental findings that were found in 92% of the sample studied, with 225 exams where the FOV covered just the maxilla, 99 in the mandible and 236 in the maxilla/mandible. The incidental findings were more frequent in the tooth zone, with 27.32% of the findings, followed by airways with 24.46%, soft tissue calcifications with 20.53%, ATM with 16.42%, 7.32% bone, 1.96% lesions of the jaw and 1.96% other findings. Also found were that 43.46% of the incidental findings did not need treatment or referral to another professional, 28.97% required the acquisition of new images for monitoring and 27.55% needed treatment or referral. The present study confirmed the high frequency of incidental findings in CBCT scans. It was concluded that it is necessary to interpret and report the total volume obtained in the CBCT examinations and not only the purpose of the examination region.
|
177 |
Cisto ósseo simples: considerações sobre o diagnóstico e a possibilidade da cura espontânea / Simple bone cyst: considerations on the diagnosis and the possibility of self-healingMaíra de Paula Leite Battisti 03 July 2014 (has links)
O Cisto Ósseo Simples (COS) ou Cisto Ósseo Traumático (COT), é uma cavidade óssea não epitelizada, de conteúdo fluido sero-sanguinolento ou vazia. Muito se discute sobre sua etiopatogenia que ainda continua incerta. O tratamento de escolha ainda é a exploração cirúrgica, embora haja vários casos de sucesso descritos na literatura nos quais escolheu-se a proservação após criteriosa avaliação clínica e radiográfica. A porposta deste trabalho foi: 1) Analisar o estado atual de remodelação óssea espontânea em casos diagnosticados clínica e radiograficamente, sem cirurgia, que estão sendo seguidos por diferentes períodos de tempo (proservados). 2) Analisar a contribuição da Tomografia Computadorizada de Feixe Cônico (TCFC) no diagnóstico imaginológico do COS. 3) Comparar características do COS na radiografia panorâmica com as características encontradas no exame tomográfico. Foram selecionados 22 pacientes diagnosticados com COS e em acompanhamento clinico e radiográfico, segundo protocolo proposto por Damante et al. (2002). Dos 22 pacientes, 13 foram avaliados clinica e radiograficamente e nove pacientes foram avaliados apenas radiograficamente, através do banco de imagens do Departamento de Estomatologia. Foram avaliados 7 exames tomográficos, sendo que 6 deles também estavam disponíveis no banco de imagens. Três examinadores avaliaram as radiografias panorâmicas dos 22 pacientes e apenas 1 examinador avaliou as tomografias computadorizadas. Foi realizado o teste Kappa para calibração intra e interexaminador e aplicada uma estatística indutiva e descritiva aos resultados. Apenas um paciente apresentou resposta positiva à palpação e percussão dos dentes na região afetada. A concordância intra e interexaminador foi calculada pelo teste Kappa e valores satisfatórios foram encontrados. A maioria dos cistos avaliados foram classificados nas categorias 3, 4 ou 5 (em involução, quase completamente resolvido ou completamente resolvido, respectivamente). Das 7 TCFCs analisadas 6 demonstraram presença de adelgaçamento e perfuração de pelo menos uma das corticais. A amostra estudada evidenciou um processo de resolução espontânea do COS, uma vez que a maioria das lesões encontrou-se em processo de regressão ou já resolvidos, após diferentes períodos de acompanhamento. Isso reafirma as hipóteses presentes na literatura, sobre a possível resolução espontânea do COS, diante da qual a cirurgia torna-se desnecessária, uma vez que em sua maioria, são assintomáticos e não apresentam sinais clínicos. O exame tomográfico forneceu maiores detalhes imaginológicos do COS em relação à radiografia panorâmica, uma vez que foi possível detectar a presença de adelgaçamento e perfuração das corticais ósseas em 86% dos casos. / Simple Bone Cyst (SBC) or Traumatic Bone Cyst (TBC) is a non- epithelialized bone cavity, with sero-bloody fluid or empty content. There is debate regarding its pathogenesis that still remains unclear. The treatment of choice is still the surgical exploration, although there are successful cases described in the literature in which just the follow-up with clinical and radiographic evaluation were done. 1)To analyze the current state of spontaneous bone remodeling (self-healing) in cases diagnosed clinically and radiographically without surgery, being followed by different periods of time. 2) Analyze the contribution of Cone Beam Computed Tomography (CBCT) imaging in the diagnosis of SBC. 3) To compare the characteristics of SBC panoramic radiograph with features found on CT scan. Twenty-two patients diagnosed with SBC without surgery and submitted to Damante et al. protocol of follow-up (2002), were selected. Thirteen patients (13/22) were evaluated clinically and radiographically and nine patients (9/22) were evaluated only radiographically. Of these 22 patients, 7 patients had CT scans in the images database and these exams were evaluated too. Three observers evaluated the panoramic radiographs of 22 patients and only one examiner evaluated the CT scans. Kappa test was performed for intra and inter-calibration and inductive an descriptive statistics was applied to the results. Only one patient had a positive response to palpation and percussion of the teeth in the cyst area. The intra and inter agreement was calculated by Kappa test and values were found satisfactory. Most of the cysts evaluated were rated as 3, 4 or 5 (\"remodeling,\" \"almost completely resolved\" or \"completely resolved,\" respectively). Six of the 7 TCFCs analyzed showed the presence of thinning and perforation of at least one bone cortical. The study showed a process of spontaneous resolution (self-healing) of the SBC, since most cysts found in the regression process and resolved after different follow-up periods. This reaffirms the assumptions in the literature about the spontaneous resolution of the SBC, since the majority are asymptomatic and do not exhibit clinical signs. A CT scan can give new information about the imaging aspects of SBC, since it was possible to detect the presence of thinning and perforation of cortical bone in 86% of cases.
|
178 |
Avaliação do seio maxilar por meio de tomografia computadorizada de feixe cônico / Maxillary sinus evaluation through Cone Beam Computed TomographyOtávio Pagin 26 May 2011 (has links)
O cirurgião-dentista necessita muitas vezes visualizar imagens associadas a estruturas importantes onde um bom conhecimento da anatomia crânio facial e dentomaxilar é imprescindível na elaboração de um diagnóstico correto. O seio maxilar é uma estrutura anatômica localizada no terço médio da face, sendo de extrema importância por estar localizado muito próximo às estruturas dentárias posteriores, devendo fazer parte do conhecimento dos cirurgiões-dentistas, nas diversas especialidades. Nesse estudo foram avaliados 50 exames de Tomografia Computadorizada de Feixe Cônico (TCFC) onde os seios maxilares podiam ser visualizados, resultando em um total de 78 extensões para diferentes regiões foram encontradas, 17 indivíduos apresentavam espessamento da membrana sinusal, 14 mostravam imagens compatíveis com cistos de retenção de muco e 6 apresentavam velamento do seio maxilar, variando entre total e parcial. Um total de 64 septos foram identificados no interior da cavidade sinusal, 86 cúpulas alveolares localizadas nas raízes dos diferentes dentes, 126 raízes foram encontradas em íntimo contato com o assoalho sinusal. Os resultados foram estatisticamente significantes para a relação entre cúpulas alveolares e extensões alveolares para a raiz palatina do dente 26, a presença de septos no teto dos seios maxilares de mulheres e da relação da média da região desdentada do dente 26 para os homens, com os valores de p < 0,05. Diversos fatores relacionados à morfologia do osso maxilar, a ausência de dentes e a própria conformação da cavidade sinusal podem resultar em diferentes formatos entre indivíduos e variações até no mesmo indivíduo. O exame por Tomografia Computadorizada de Feixe Cônico (TCFC) dos seios maxilares permite uma avaliação tridimensional e sua relação com as estruturas adjacentes, ou seja, uma perfeita reprodução da região dentomaxilofacial, auxiliando de maneira precisa os profissionais que irão intervir junto ou próximo a essa estrutura anatômica. / Dentistry professionals are required to analyze, in many cases, images associated to important structures where a great knowledge of the dentomaxillofacial anatomy is vital for an accurate diagnostic. The maxillary sinus is an anatomical structure that occupies the upper 2/3s of the maxillary bone and it is very important because the proximity with the posterior dental structures, it must be well known by dentists in the several specialties. In this study, 50 Cone Beam Computed Tomography (CBCT) exams in which the maxillary sinus could be evaluated, showed a total of 78 extension toward different regions were achieved, 17 subjects displayed a mucosal thickening, 14 evidenced a compatible imaging of mucous retention cysts and 6 presented a partially or completely filled maxillary sinus. A total of 64 maxillary sinus septa were identified, 86 different roots were localized inside de sinus, 126 roots were found to be in proximity with the sinus floor. The results were statistically significant to the relation made between these roots, which were inside the sinus and the alveolar extensions to the palatine root of the tooth 26, the presence of maxillary sinus septa located in the roof of the women maxillary sinus and the relation made between the median value for men in the edentulous region of the tooth 26, with a p value < 0,05. Its anatomy is one of the most varied, and many factors related to the maxillary bone morphology like edentulousness and the sinus conformation can result on different shapes, even in the same person. The Cone Beam Computed Tomography (CBCT) of the maxillary sinus provides a three-dimensional evaluation and its relationship with the boundary structures. It is a precise reproduction of the dentomaxillofacial region, providing valuable support to the professional who will work on or next to this anatomical structure.
|
179 |
Artéria alveolar superior posterior em indivíduos com fissuras labiopalatinas em exames de tomografia computadorizada de feixe cônico / Posterior superior alveolar artery in cleft lip/palate in exams cone beam computed tomographyEymi Valery Cazas Duran 27 March 2018 (has links)
Objetivos: Avaliar as características do canal da artéria alveolar superior posterior (AASP) em exames de tomografia de feixe conico (TCFC) em indivíduos com fissura labiopalatina (FI) e comparar com indivíduos não fissurados (NF). Material e Métodos: Foram analisados 150 exames de TCFC de FI e 150 TCFC de NF. Os critérios de exclusão foram: exames de pacientes sindrômicos, presença de lesões intraósseas, desdentados totais, outras alterações que interferem a visivilidade do canal da AASP, presença de artefatos, idade abaixo de 20 anos e exames que não incluíam toda a maxila. As características avaliadas foram à presença/ausência, localização em relação ao seio maxilar, diâmetro, distancia em relação ao rebordo alveolar e assoalho do seio maxilar e término presença/ausência de anastomose com a artéria alveolar superior anterior (AASA).Os testes estatísticos aplicados foram Kappa, Dahlberg Fischers, test t. Resultados: O grupo de FI foi constituído de 75 homens e 75 mulheres, com idade média de 29,8 anos. O grupo de NF foi composto por 75 homens 75 mulheres com idade média de 40,3 anos. O Kappa para a concordância da presença e ausência do canal da AASP foi: intra-avaliador 0,8 substancial e inter-avaliador de 0,7 subtancial. O Dahlberg intra-avaliador foi de 0, 75 excelente e inter-avaliador de 0,7 satisfatório. No ponto de ingresso o canal AASP esteve presente em 100% em FI e em 100% em NF, em todos os casos o canal da AASP era bilateral. Os diâmetros, do canal da AASP, foram significativamente diferentes entre os dois grupos, sendo maior para os FI (Test t P < 0,0001). A localização em relação ao ponto de ingresso no seio maxilar foi estatisticamente significante entre ambos os grupos, nos FI a maior frequência foi no terço médio (Fisher\' s P <0,0001) e superior do seio maxilar (Fisher\' s P < 0,0071 lado esquerdo), e os NF apresentaram maior frequência foi no terço inferior (Fisher\' s P < 0,0001). Em relação à distância da AASP ao rebordo alveolar e ao assoalho do seio maxilar, não houve resultados estatisticamente significantes. Em relação aos tipos de términos não houve diferença estatisticamente significante entre os grupos. Conclusões: De acordo com material e métodos realizados, o canal da AASP apresentou maior diâmetro e localização mais superior no seio maxilar em FI quando comparado com NF. Esses resultados podem indicar um maior risco de sangramento durante cirurgias para os portadores de fissura labiopalatina. / Objectives: This study evaluates the characteristics of the posterior superior alveolar artery canal (AASP) in individuals with cleft lip and palate (FI) and compares with individuals without cleft lip and palate (NF). Material and Methods: 150 Cone-Beam Computed Tomography (TCFC) were evaluated from both FI and NF 150 TCFC according to the criteria outlined above. Exclusion criteria were: Sindromic patients, exams with alteration introsseous, edentulous maxilla, artifacts, people below 20 years of age, exams that did not include all maxilla. The characteristics evaluated include presence/absence, location in to maxillary sinus, diameter, distance in relation to the alveolar crest and maxillary sinus floor and presence/absence of anastomosis with the anterior superior alveolar artery canal (AASA). The statistical tests used were Kappa, Dahlberg, Fisher\'s and test t. Results: The group of FI was composed of 75 men and 75 women, with an average age of 29.8. The NF group was composed of 75 men and 75 women with average of age 40.3. In relation to the presence/absence of the AASP canal, result from an evaluation by the intra-rater was 0,8 substancial and inter-rater showed 0.7substantial. O Dahlberg intra-rater was 0.75 excelent and inter-rater 0.7 satisfactory. The prevalence of the AASP canal was100% in the FI group and NF. Regarding the diameters of the AASP canal there were significant differences between the two groups, and was considerably greater for the FI group (Test t p < 0.0001). With respect to location in relation to the point of entry in the maxillary sinus results showed significant statistical difference between both groups, with the NF group possessing higher frequency in the middle third (Fishers p <0.0001) and upper third of maxillary sinus (Fishers p < 0.0071 left side) and NF had higher frequency was in lower third (Fishers P <0.0001). There was no significant statistical difference in relation to the distance of the AASP to alveolar crest and to the floor maxillary sinus. The same was true in relation to the types of terms. Conclusion: According to the material and methods the AASP canal present larger diameter and more premium location in the maxillary sinus in individuals with FI compared with NF. The results indicate a higher risk of bleeding during surgery for patients with cleft lip and palate.
|
180 |
Avaliação da radiografia panorâmica e da tomografia computadorizada por feixe cônico no planejamento cirurgico de terceiros molares mandibulares - Estudo clínico / Evaluation of panoramic radiography and cone beam computed tomography in surgical planning of mandibular third molars - Clinical studyMarcelo Bonifacio da Silva Sampieri 04 September 2015 (has links)
A cirurgia de terceiros molares inferiores exige treinamento, pois acidentes e complicações podem ocorrer. Uma dessas complicações é o dano ao nervo alveolar inferior. Sendo assim torna-se importante avaliar a posição do terceiro molar e estabelecer o relacionamento deste com o canal mandibular, para minimizar o risco de injúria ao nervo, bem como auxiliar no planejamento da exodontia deste dente. A radiografia panorâmica é o instrumento padrão de diagnóstico para este propósito. Porém, se esta indica que existe um íntimo relacionamento entre o terceiro molar e o canal mandibular, uma investigação adicional usando tomografia computadorizada de feixe cônico pode ser recomendada para verificar a relação tridimensional entre ambos. Este estudo se propôs a avaliar comparativamente, radiografia panorâmica e tomografia computadorizada por feixe cônico, na determinação do número de raízes do correto planejamento cirúrgico e da relação entre o terceiro molar inferior com o canal mandibular após a exodontia de 20 terceiros molares inferiores. Após as análises da radiografia panorâmica e da tomografia computadorizada por feixe cônico, feitas por examinadores independentes e cegos aos achados pós-cirúrgicos, observou-se que a tomografia computadorizada por feixe cônico foi superior a radiografia panorâmica em determinar o correto número de raízes. A tomografia computadorizada por feixe cônico não foi superior a radiografia panorâmica em determinar o correto planejamento cirúrgico. Estes dados não foram estatisticamente significantes (p>0,05). O achado radiográfico tipo 2 (escurecimento das raízes) foi o tipo mais relacionado com a ausência de osso cortical entre o terceiro molar inferior e o canal mandibular (achado tomográfico) sendo estatisticamente significante (p<0,05).Com base nas constatações obtidas neste estudo, pode-se concluir que a TCFC seria mais bem indicada no planejamento cirúrgico, quando a radiografia panorâmica sugerisse claramente uma situação de risco, ou seja a sobreposição do canal mandibular em relação às raízes do terceiro molar inferior (escurecimento das raízes). / The third molars surgery requires training, because accidents and complications can occur. One of these complications is the damage to the inferior alveolar nerve. It is important to evaluate the position and establish the third molar relationship with the mandibular canal to minimize the nerve injury risk and assist in planning the extraction of this tooth. Panoramic radiography is the standard diagnostic tool for this purpose. However, if it indicates that there is an intimate relationship between the third molar and mandibular canal, further investigation using Cone beam computed tomography may be recommended to check the three-dimensional relationship between tooth and mandibular canal. This study aimed to evaluate and compare the effectiveness of panoramic radiography and Cone beam computed tomography to determine the correct number of roots, the surgical planning and the relation between mandibular third molar and mandibular canal after extraction of 20 mandibular third molars. After analysis of panoramic radiography and cone beam computed tomography, performed by independent examiners blind to the surgical aspects, it was observed that cone beam computed tomography was superior to the panoramic radiography in determining the correct number of roots. Cone beam computed tomography was no more effective than the panoramic radiography in determining the correct surgical planning. These data were not statistically significant(p>0,05). The radiographic finding type 2(darkening of roots) was more related with absence of cortical bone between the mandibular canal and third molar(CBCT finding) being statistically significant(p<0,05). Based on the findings obtained in this study, it can be concluded that CBCT would be best used in surgical planning, when the panoramic radiograph clearly suggest a risk, ie the overlap of the mandibular canal in relation to the third molar roots (darkening of the roots).
|
Page generated in 0.0626 seconds