• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 6
  • Tagged with
  • 6
  • 6
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Determinação de estimulantes anfetamínicos no fluido oral : especificidade dos métodos de triagem e análise confirmatória

Souza, Daniele Zago January 2010 (has links)
O Brasil destaca-se no cenário mundial em relação ao consumo de estimulantes anfetamínicos (ATS), e estudos nacionais têm evidenciado grande prevalência na utilização destas substâncias por motoristas profissionais. O fluido oral apresenta uma série de vantagens sobre as matrizes tradicionais para a monitorização do consumo de ATS no trânsito, e vem sendo empregada em diversos países. Este trabalho objetivou avaliar a especificidade de imunoensaios comerciais na detecção preliminar dos ATS comercializados no Brasil em amostras de fluído oral e desenvolver e validar um método para a confirmação e quantificação de anfetamina (AMP), metanfetamina (MET), anfepramona (DIE), fenproporex (FEN) e metilfenidato (MPH) no fluído oral por microextração em fase sólida (SPME) e cromatografia a gás com detector de massas (CG/EM). A especificidade analítica dos imunoensaios foi avaliada por meio do estudo das informações técnicas de diversos produtos e da realização de ensaios experimentais com três testes. O método confirmatório por SPME-CG/EM foi desenvolvido a partir da técnica de imersão (DI-SPME), sob agitação magnética, à temperatura ambiente, utilizando fibras revestida por polidimetilsiloxano (30 μm), propilcloroformato como agente derivatizante e adição de Na2CO3 e de Na2SO4 para aumentar o pH e a força iônica do meio, respectivamente. Os testes imunológicos atualmente disponíveis para a triagem de ATS em fluido oral são importados e não detectam, mesmo em altas concentrações, os principais ATS consumidos no Brasil: FEN, DIE e MPH. O método por SPME-CG/EM foi linear para os ATS estudados no intervalo de 2-256 ng.mL-1, exceto para o FEN cujo intervalo foi de 4-256 ng.mL-1. Os limites de detecção foram 0,5 ng.mL-1 (MET), 1 ng.mL-1 (MPH) e 2 ng.mL-1 (DIE, AMP, FEN). A exatidão do método situou-se entre 98,2 – 111,9% e a precisão não excedeu 15% de desvio padrão relativo. O método foi aplicado com sucesso na estimação do perfil farmacocinético do FEN e da AMP no fluído oral de seis indivíduos do sexo masculino, após a administração de dose única de especialidade farmacêutica nacional contendo 25 mg de cloridrato de FEN. / The Brazil stands out on the world as a major consumer of amphetamine-type stimulants (ATS), and several national studies have shown high prevalence in the consumption of these substances by professional drivers. Oral fluid has many advantages over the conventional biological fluids for monitoring ATS use on roads, and has been employed with this purpose in several countries. The aim of this study is to assess the specificity/cross-reactivity of commercial oral fluid immunoassays in detecting the prescription ATS marketed in Brazil and to develop and validate a method for confirmation and quantification of amphetamine (AMP), methamphetamine (MET), amfepramone (DIE), fenproporex (FEN) and methylphenidate (MPH) in oral fluid by solid phase microextraction (SPME) and gas chromatography-mass spectrometry (GC-MS). Analytical specificity of immunoassays was evaluated through the study of the technical information of commercial products and through experimental testing of three kits. The confirmatory SPME-GC-MS method employed SPME immersion technique (DI-SPME), under magnetic stirring, at room temperature, using polydimethylsiloxane (30 μm) fibers, in-matrix propylchloroformate derivatization, Na2CO3 and Na2SO4 to increase both pH and ionic strength. Immunological tests currently available for ATS screening in oral fluid are imported and do not detect, even at high concentrations, the main ATS consumed in Brazil: FEN, MPH and DIE. The SPME-GC-MS method was linear for the studied ATS over the range of 2-256 ng.mL-1, except for FEN where the linear range was 4-256 ng.mL-1. The detection limits were 0.5 ng.mL-1 (MET), 1 ng.mL-1 (MPH) and 2 ng.mL-1 (DIE, AMP, FEN). Accuracy was within 98.2 – 111.9% of the target concentrations and precision did not exceed 15% of relative standard deviation. The method was successfully applied to estimate the pharmacokinetic profile of FEN and AMP in oral fluid of six male subjects after administration of a single dose of 25 mg FEN hydrochloride.
2

Determinação de estimulantes anfetamínicos no fluido oral : especificidade dos métodos de triagem e análise confirmatória

Souza, Daniele Zago January 2010 (has links)
O Brasil destaca-se no cenário mundial em relação ao consumo de estimulantes anfetamínicos (ATS), e estudos nacionais têm evidenciado grande prevalência na utilização destas substâncias por motoristas profissionais. O fluido oral apresenta uma série de vantagens sobre as matrizes tradicionais para a monitorização do consumo de ATS no trânsito, e vem sendo empregada em diversos países. Este trabalho objetivou avaliar a especificidade de imunoensaios comerciais na detecção preliminar dos ATS comercializados no Brasil em amostras de fluído oral e desenvolver e validar um método para a confirmação e quantificação de anfetamina (AMP), metanfetamina (MET), anfepramona (DIE), fenproporex (FEN) e metilfenidato (MPH) no fluído oral por microextração em fase sólida (SPME) e cromatografia a gás com detector de massas (CG/EM). A especificidade analítica dos imunoensaios foi avaliada por meio do estudo das informações técnicas de diversos produtos e da realização de ensaios experimentais com três testes. O método confirmatório por SPME-CG/EM foi desenvolvido a partir da técnica de imersão (DI-SPME), sob agitação magnética, à temperatura ambiente, utilizando fibras revestida por polidimetilsiloxano (30 μm), propilcloroformato como agente derivatizante e adição de Na2CO3 e de Na2SO4 para aumentar o pH e a força iônica do meio, respectivamente. Os testes imunológicos atualmente disponíveis para a triagem de ATS em fluido oral são importados e não detectam, mesmo em altas concentrações, os principais ATS consumidos no Brasil: FEN, DIE e MPH. O método por SPME-CG/EM foi linear para os ATS estudados no intervalo de 2-256 ng.mL-1, exceto para o FEN cujo intervalo foi de 4-256 ng.mL-1. Os limites de detecção foram 0,5 ng.mL-1 (MET), 1 ng.mL-1 (MPH) e 2 ng.mL-1 (DIE, AMP, FEN). A exatidão do método situou-se entre 98,2 – 111,9% e a precisão não excedeu 15% de desvio padrão relativo. O método foi aplicado com sucesso na estimação do perfil farmacocinético do FEN e da AMP no fluído oral de seis indivíduos do sexo masculino, após a administração de dose única de especialidade farmacêutica nacional contendo 25 mg de cloridrato de FEN. / The Brazil stands out on the world as a major consumer of amphetamine-type stimulants (ATS), and several national studies have shown high prevalence in the consumption of these substances by professional drivers. Oral fluid has many advantages over the conventional biological fluids for monitoring ATS use on roads, and has been employed with this purpose in several countries. The aim of this study is to assess the specificity/cross-reactivity of commercial oral fluid immunoassays in detecting the prescription ATS marketed in Brazil and to develop and validate a method for confirmation and quantification of amphetamine (AMP), methamphetamine (MET), amfepramone (DIE), fenproporex (FEN) and methylphenidate (MPH) in oral fluid by solid phase microextraction (SPME) and gas chromatography-mass spectrometry (GC-MS). Analytical specificity of immunoassays was evaluated through the study of the technical information of commercial products and through experimental testing of three kits. The confirmatory SPME-GC-MS method employed SPME immersion technique (DI-SPME), under magnetic stirring, at room temperature, using polydimethylsiloxane (30 μm) fibers, in-matrix propylchloroformate derivatization, Na2CO3 and Na2SO4 to increase both pH and ionic strength. Immunological tests currently available for ATS screening in oral fluid are imported and do not detect, even at high concentrations, the main ATS consumed in Brazil: FEN, MPH and DIE. The SPME-GC-MS method was linear for the studied ATS over the range of 2-256 ng.mL-1, except for FEN where the linear range was 4-256 ng.mL-1. The detection limits were 0.5 ng.mL-1 (MET), 1 ng.mL-1 (MPH) and 2 ng.mL-1 (DIE, AMP, FEN). Accuracy was within 98.2 – 111.9% of the target concentrations and precision did not exceed 15% of relative standard deviation. The method was successfully applied to estimate the pharmacokinetic profile of FEN and AMP in oral fluid of six male subjects after administration of a single dose of 25 mg FEN hydrochloride.
3

Determinação de estimulantes anfetamínicos no fluido oral : especificidade dos métodos de triagem e análise confirmatória

Souza, Daniele Zago January 2010 (has links)
O Brasil destaca-se no cenário mundial em relação ao consumo de estimulantes anfetamínicos (ATS), e estudos nacionais têm evidenciado grande prevalência na utilização destas substâncias por motoristas profissionais. O fluido oral apresenta uma série de vantagens sobre as matrizes tradicionais para a monitorização do consumo de ATS no trânsito, e vem sendo empregada em diversos países. Este trabalho objetivou avaliar a especificidade de imunoensaios comerciais na detecção preliminar dos ATS comercializados no Brasil em amostras de fluído oral e desenvolver e validar um método para a confirmação e quantificação de anfetamina (AMP), metanfetamina (MET), anfepramona (DIE), fenproporex (FEN) e metilfenidato (MPH) no fluído oral por microextração em fase sólida (SPME) e cromatografia a gás com detector de massas (CG/EM). A especificidade analítica dos imunoensaios foi avaliada por meio do estudo das informações técnicas de diversos produtos e da realização de ensaios experimentais com três testes. O método confirmatório por SPME-CG/EM foi desenvolvido a partir da técnica de imersão (DI-SPME), sob agitação magnética, à temperatura ambiente, utilizando fibras revestida por polidimetilsiloxano (30 μm), propilcloroformato como agente derivatizante e adição de Na2CO3 e de Na2SO4 para aumentar o pH e a força iônica do meio, respectivamente. Os testes imunológicos atualmente disponíveis para a triagem de ATS em fluido oral são importados e não detectam, mesmo em altas concentrações, os principais ATS consumidos no Brasil: FEN, DIE e MPH. O método por SPME-CG/EM foi linear para os ATS estudados no intervalo de 2-256 ng.mL-1, exceto para o FEN cujo intervalo foi de 4-256 ng.mL-1. Os limites de detecção foram 0,5 ng.mL-1 (MET), 1 ng.mL-1 (MPH) e 2 ng.mL-1 (DIE, AMP, FEN). A exatidão do método situou-se entre 98,2 – 111,9% e a precisão não excedeu 15% de desvio padrão relativo. O método foi aplicado com sucesso na estimação do perfil farmacocinético do FEN e da AMP no fluído oral de seis indivíduos do sexo masculino, após a administração de dose única de especialidade farmacêutica nacional contendo 25 mg de cloridrato de FEN. / The Brazil stands out on the world as a major consumer of amphetamine-type stimulants (ATS), and several national studies have shown high prevalence in the consumption of these substances by professional drivers. Oral fluid has many advantages over the conventional biological fluids for monitoring ATS use on roads, and has been employed with this purpose in several countries. The aim of this study is to assess the specificity/cross-reactivity of commercial oral fluid immunoassays in detecting the prescription ATS marketed in Brazil and to develop and validate a method for confirmation and quantification of amphetamine (AMP), methamphetamine (MET), amfepramone (DIE), fenproporex (FEN) and methylphenidate (MPH) in oral fluid by solid phase microextraction (SPME) and gas chromatography-mass spectrometry (GC-MS). Analytical specificity of immunoassays was evaluated through the study of the technical information of commercial products and through experimental testing of three kits. The confirmatory SPME-GC-MS method employed SPME immersion technique (DI-SPME), under magnetic stirring, at room temperature, using polydimethylsiloxane (30 μm) fibers, in-matrix propylchloroformate derivatization, Na2CO3 and Na2SO4 to increase both pH and ionic strength. Immunological tests currently available for ATS screening in oral fluid are imported and do not detect, even at high concentrations, the main ATS consumed in Brazil: FEN, MPH and DIE. The SPME-GC-MS method was linear for the studied ATS over the range of 2-256 ng.mL-1, except for FEN where the linear range was 4-256 ng.mL-1. The detection limits were 0.5 ng.mL-1 (MET), 1 ng.mL-1 (MPH) and 2 ng.mL-1 (DIE, AMP, FEN). Accuracy was within 98.2 – 111.9% of the target concentrations and precision did not exceed 15% of relative standard deviation. The method was successfully applied to estimate the pharmacokinetic profile of FEN and AMP in oral fluid of six male subjects after administration of a single dose of 25 mg FEN hydrochloride.
4

Desenvolvimento e validação de metodologia analítica para caracterização e quantificação de derivados anfetamínicos / Development and validation of analytical methodology for characterization and quantification of amphetamine derivatives

Franck, Maria Cristina January 2008 (has links)
O consumo lícito e ilícito de derivados anfetamínicos tem aumentado significativamente nos últimos anos, acentuando a necessidade de métodos analíticos adequados para a determinação dessas substâncias pelos laboratórios de toxicologia forense. Este trabalho teve como objetivo o desenvolvimento de métodos cromatográficos para a análise simultânea de anfepramona (DEP), femproporex (FEM), metilfenidato (MPH), 4-bromo-2,5-dimetoxi-anfetamina (DOB) e 4-bromo-2,5-dimetoxi-fenetilamina (2-CB) em amostras não-biológicas. Foram desenvolvidos métodos de detecção por cromatografia a gás com detector de ionização de chama (CG/DIC), de confirmação por cromatografia a gás com detector de espectrometria de massas (CG/EM) e de detecção e quantificação por cromatografia líquida de alta eficiência com detector ultravioleta (CLAE/UV). Os derivados anfetamínicos estudados foram identificados e quantificados simultaneamente através do método CLAE/UV utilizando uma coluna C-18, comprimento de onda 206 nm e modo isocrático. DEP, FEM, MPH e DOB foram detectados simultaneamente por CG/DIC e CG/EM utilizando colunas capilares, sem derivatização e com um tempo de corrida inferior a 10 minutos. Os métodos desenvolvidos foram validados através da avaliação dos parâmetros de linearidade, especificidade, precisão, exatidão, limite de detecção, limite de quantificação e robustez. Os métodos desenvolvidos são de fácil execução, rápidos e adequados para a utilização na rotina laboratorial. / The consumption of both licit and illicit amphetamine derivatives has grown increasingly in recent years, emphasizing the need for analytical methods suitable for identification and quantification of these substances by forensic toxicology laboratories. This aim of this work was to develop and validate methods for the simultaneous chromatographic analysis of amfepramone (diethylpropione, DEP), fenproporex (FEM), methylphenidate (MPH), 4-bromo-2,5-dimethoxyamphetamine (DOB), and 4-bromo-2,5 dimethoxyphenetylamine (2-CB) in non-biological samples. Methods of detection by gas chromatography with flame ionization detector, (GC/FID), confirmation by gas chromatography with mass spectrometry detection (GC/MS), and detection and quantification by high performance liquid chromatography with ultraviolet detection (HPLC/UV) were developed. The amphetamine derivatives studied were identified and quantified simultaneously by HPLC/UV using a RP-C18, 206 nm wavelength and isocratic conditions. DEP, FEM, MPH and DOB were detected both by GC/FID and GC/MS using capillary columns, without derivatization and running times lower than 10 minutes. The validation parameters accessed were linearity, specificity, precision, accuracy, limit of detection, limit of quantification and robustness. The developed methods are easy to implement, fast and suitable for use in routine laboratory analysis.
5

Desenvolvimento e validação de metodologia analítica para caracterização e quantificação de derivados anfetamínicos / Development and validation of analytical methodology for characterization and quantification of amphetamine derivatives

Franck, Maria Cristina January 2008 (has links)
O consumo lícito e ilícito de derivados anfetamínicos tem aumentado significativamente nos últimos anos, acentuando a necessidade de métodos analíticos adequados para a determinação dessas substâncias pelos laboratórios de toxicologia forense. Este trabalho teve como objetivo o desenvolvimento de métodos cromatográficos para a análise simultânea de anfepramona (DEP), femproporex (FEM), metilfenidato (MPH), 4-bromo-2,5-dimetoxi-anfetamina (DOB) e 4-bromo-2,5-dimetoxi-fenetilamina (2-CB) em amostras não-biológicas. Foram desenvolvidos métodos de detecção por cromatografia a gás com detector de ionização de chama (CG/DIC), de confirmação por cromatografia a gás com detector de espectrometria de massas (CG/EM) e de detecção e quantificação por cromatografia líquida de alta eficiência com detector ultravioleta (CLAE/UV). Os derivados anfetamínicos estudados foram identificados e quantificados simultaneamente através do método CLAE/UV utilizando uma coluna C-18, comprimento de onda 206 nm e modo isocrático. DEP, FEM, MPH e DOB foram detectados simultaneamente por CG/DIC e CG/EM utilizando colunas capilares, sem derivatização e com um tempo de corrida inferior a 10 minutos. Os métodos desenvolvidos foram validados através da avaliação dos parâmetros de linearidade, especificidade, precisão, exatidão, limite de detecção, limite de quantificação e robustez. Os métodos desenvolvidos são de fácil execução, rápidos e adequados para a utilização na rotina laboratorial. / The consumption of both licit and illicit amphetamine derivatives has grown increasingly in recent years, emphasizing the need for analytical methods suitable for identification and quantification of these substances by forensic toxicology laboratories. This aim of this work was to develop and validate methods for the simultaneous chromatographic analysis of amfepramone (diethylpropione, DEP), fenproporex (FEM), methylphenidate (MPH), 4-bromo-2,5-dimethoxyamphetamine (DOB), and 4-bromo-2,5 dimethoxyphenetylamine (2-CB) in non-biological samples. Methods of detection by gas chromatography with flame ionization detector, (GC/FID), confirmation by gas chromatography with mass spectrometry detection (GC/MS), and detection and quantification by high performance liquid chromatography with ultraviolet detection (HPLC/UV) were developed. The amphetamine derivatives studied were identified and quantified simultaneously by HPLC/UV using a RP-C18, 206 nm wavelength and isocratic conditions. DEP, FEM, MPH and DOB were detected both by GC/FID and GC/MS using capillary columns, without derivatization and running times lower than 10 minutes. The validation parameters accessed were linearity, specificity, precision, accuracy, limit of detection, limit of quantification and robustness. The developed methods are easy to implement, fast and suitable for use in routine laboratory analysis.
6

Desenvolvimento e validação de metodologia analítica para caracterização e quantificação de derivados anfetamínicos / Development and validation of analytical methodology for characterization and quantification of amphetamine derivatives

Franck, Maria Cristina January 2008 (has links)
O consumo lícito e ilícito de derivados anfetamínicos tem aumentado significativamente nos últimos anos, acentuando a necessidade de métodos analíticos adequados para a determinação dessas substâncias pelos laboratórios de toxicologia forense. Este trabalho teve como objetivo o desenvolvimento de métodos cromatográficos para a análise simultânea de anfepramona (DEP), femproporex (FEM), metilfenidato (MPH), 4-bromo-2,5-dimetoxi-anfetamina (DOB) e 4-bromo-2,5-dimetoxi-fenetilamina (2-CB) em amostras não-biológicas. Foram desenvolvidos métodos de detecção por cromatografia a gás com detector de ionização de chama (CG/DIC), de confirmação por cromatografia a gás com detector de espectrometria de massas (CG/EM) e de detecção e quantificação por cromatografia líquida de alta eficiência com detector ultravioleta (CLAE/UV). Os derivados anfetamínicos estudados foram identificados e quantificados simultaneamente através do método CLAE/UV utilizando uma coluna C-18, comprimento de onda 206 nm e modo isocrático. DEP, FEM, MPH e DOB foram detectados simultaneamente por CG/DIC e CG/EM utilizando colunas capilares, sem derivatização e com um tempo de corrida inferior a 10 minutos. Os métodos desenvolvidos foram validados através da avaliação dos parâmetros de linearidade, especificidade, precisão, exatidão, limite de detecção, limite de quantificação e robustez. Os métodos desenvolvidos são de fácil execução, rápidos e adequados para a utilização na rotina laboratorial. / The consumption of both licit and illicit amphetamine derivatives has grown increasingly in recent years, emphasizing the need for analytical methods suitable for identification and quantification of these substances by forensic toxicology laboratories. This aim of this work was to develop and validate methods for the simultaneous chromatographic analysis of amfepramone (diethylpropione, DEP), fenproporex (FEM), methylphenidate (MPH), 4-bromo-2,5-dimethoxyamphetamine (DOB), and 4-bromo-2,5 dimethoxyphenetylamine (2-CB) in non-biological samples. Methods of detection by gas chromatography with flame ionization detector, (GC/FID), confirmation by gas chromatography with mass spectrometry detection (GC/MS), and detection and quantification by high performance liquid chromatography with ultraviolet detection (HPLC/UV) were developed. The amphetamine derivatives studied were identified and quantified simultaneously by HPLC/UV using a RP-C18, 206 nm wavelength and isocratic conditions. DEP, FEM, MPH and DOB were detected both by GC/FID and GC/MS using capillary columns, without derivatization and running times lower than 10 minutes. The validation parameters accessed were linearity, specificity, precision, accuracy, limit of detection, limit of quantification and robustness. The developed methods are easy to implement, fast and suitable for use in routine laboratory analysis.

Page generated in 0.0425 seconds