• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 6
  • Tagged with
  • 6
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Desenvolvimento de um método analítico para a detecção de metanfetamina utilizando Espalhamento Raman Intensificado por Superfície (SERS)

Souza, Marco Antonio de 26 February 2018 (has links)
Dissertação (mestrado)—Universidade de Brasília, Instituto de Ciências Biológicas, Pós-Graduação em Nanociência e Nanobiotecnologia, 2018. / Submitted by Raquel Viana (raquelviana@bce.unb.br) on 2018-07-18T20:44:47Z No. of bitstreams: 1 2018_MarcoAntoniodeSouza.pdf: 6620992 bytes, checksum: 636bfce176d742c13924ca54658692ad (MD5) / Approved for entry into archive by Raquel Viana (raquelviana@bce.unb.br) on 2018-07-20T21:29:51Z (GMT) No. of bitstreams: 1 2018_MarcoAntoniodeSouza.pdf: 6620992 bytes, checksum: 636bfce176d742c13924ca54658692ad (MD5) / Made available in DSpace on 2018-07-20T21:29:51Z (GMT). No. of bitstreams: 1 2018_MarcoAntoniodeSouza.pdf: 6620992 bytes, checksum: 636bfce176d742c13924ca54658692ad (MD5) Previous issue date: 2018-07-18 / Neste trabalho é proposta uma metodologia para a detecção de metanfetamina (MA) utilizando espectroscopia Raman intensificado por superfície (SERS). A estratégia adotada envolveu o uso de substratos SERS ativos de um filme com nanopartículas de prata dispersas em gel de agarose (AgNPs/Agar) depositadas em lâminas de vidro e alumínio. A MA utilizada para preparar as soluções de trabalho para os estudos SERS foi o sal de cloridrato correspondente. Os resultados de SERS mostraram que o substrato AgNPs / Agar/Al era aquele com uma melhor relação sinal-ruído e MA foi detectada até 10-5 mol/L. Observou-se também que a intensidade SERS da MA variou com a concentração de MA atingindo um valor constante para [MA] > 2,0×10-4 mol/L, sugerindo saturação da superfície. As isotermas de adsorção ((q) vs [MA]) foram obtidas pela expressão I/I0 (I é intensidade de SERS em qualquer concentração de MA e I0 é a intensidade de SERS na concentração de MA de saturação de superfície) para a avaliação da cobertura de superfície (q). Os dados experimentais foram ajustados às isotermas de Langmuir, Frumkin e Freundlich. A análise dos resultados sugeriu que os dados experimentais foram melhor adaptados ao modelo de adsorção de Frumkin. As constantes de adsorção obtidas foram 8,3×103 mol/L e 1,7×104 mol/L, para AgNPs sintetizadas com a adição e sem adição de NaCl, levando a valores de DGads de -22,4 kJ/mol e -24,1 kJ/mol, respectivamente. O substrato AgNPs/Agar/Al também foi identificar MA em uma impressão digital contaminada com uma solução 0,01 mol/L da droga. Os espectros de SERS em diferentes locais da impressão mostraram sinais relativamente altos da MA adsorvida, sugerindo que esta metodologia é promissora para ser aplicada na detecção de outras drogas ou outras substâncias de interesse forense. / In this work a methodology is proposed for the detection of methamphetamine (MA) using surface-enhanced Raman spectroscopy (SERS). SERS was also used to study the adsorption of MA on SERS-active substrates and to verify the possibility of applying this methodology in the detection of MA in fingerprints. The strategy adopted involved the use of SERS-active substrates as films of silver nanoparticles dispersed in agarose gel (AgNPs/Agar) deposited on glass and aluminum slides. The MA used to prepare the working solutions for the SERS studies was the correspondent hydrochloride salt. It was analyzed by 1H-NMR and its purity was determined as 99.3%. AgNPs/Agar films were obtained with and without the addition of NaCl 0.01 mol.L-1 using citrate as reducing agent. The AgNPs were characterized by transmission electron microscopy (TEM) and the AgNPs/Agar films were characterized by UV-Vis and Raman spectroscopy. The mean diameter of the AgNPs were 13.8 } 6,9 nm and 13.5 } 3,6 nm, for the synthesis with added NaCl and no NaCl added, respectively. The UV-Vis results showed that the maximum absorption of the localized surface plasmon resonances (LSPR) for the AgNPs obtained with added NaCl was observed at 430.5 nm while in the synthesis with no addition of NaCl the LSPR showed a maximum at 426.5 nm. Both SERS substrates presented a strong SERS signal at ca. 240 cm-1, assigned to the Ag-Cl stretching. The SERS results showed that the AgNPs/Agar/Al substrate was the one with better signal-to-noise ratio and MA was detected down to 10-5 mol.L-1. It was also observed that the SERS intensity of MA varies with the MA concentration achieving a constant value for [MA] > 2´10-4 mol.L-1, suggesting surface saturation. Adsorption isotherms (q vs [MA]) were obtained by the expression I/I0 (I is SERS intensity at any MA concentration and I0 is the SERS intensity at the MA concentration of surface saturation) for the evaluation of the surface coverage (q). The experimental data were fitted to Langmuir, Frumkin and Freundlich isotherms. The analysis of the fitting results suggested that the experimental data were best fitted to the Frumkin adsorption model. The obtained adsorption constants were 8.3×103 mol.L-1 and 1.7×104 mol.L-1, for AgNPs synthesized with the addition and no addition of NaCl, leading to DGads values of -22.4 kJ.mol-1 and -24.1 kJ.mol-1, respectively. The AgNPs/Agar/Al substrate was also used to record a finger print contaminated with a 0.01 mol.L-1 MA solution. The SERS spectra of different sites showed relatively high signals of the adsorbed MA, suggesting that this methodology is promising to be applied in the detection of other drugs or other substances of forensic interest.
2

Alterações comportamentais e do metabolismo energético no transtorno do humor bipolar: evidências pré-clínicas e clínicas

Feier, Gustavo 21 May 2013 (has links)
Tese de Doutorado apresentada ao Programa de Pós-Graduação em Ciências da Saúde, da Universidade do Extremo Sul Catarinense – UNESC, para a obtenção do título de Doutor em Ciências da Saúde. / The animal model of mania induced by dextroamphetamine (d-AMPH) has been considered a good model for the study of bipolar disorder (BD). However, some studies have shown differences between amphetamines to induce both behavioral and biochemical changes. Besides, several studies have suggested that dysfunctional energy metabolism have a central role in BD. In the present study was investigated the potency of the d-AMPH and methamphetamine (m-AMPH) on the behavior and energetic dysfunction in the brain of rats. Were investigated also the effects of the lithium (Li) and valproate (VPT) on behavioral and energy metabolism changes in brain of rats undergoing treatment with the m-AMPH. Finally, was to compare serum creatine kinase (CK) levels between bipolar disorder patients, in the various phases (depressive, manic, and euthymic). The work was divided into three parts. Part 1: Wistar rats were given single intraperitoneal (i.p) injections of saline, d-AMPH (2 mg/kg) or m-AMPH (0.25, 0.5, 1 or 2 mg/kg). Locomotor behavior was assessed using the open-field task and activities of Krebs cycle enzymes (citrate synthase and succinate dehydrogenase), mitochondrial respiratory chain complexes (I, II, III and IV) and CK were measured in brain of rats. Part 2: Wistar rats were first given m-AMPH or saline for 14 days, and then, between days 8 and 14, rats were treated with Li, VPA or saline i.p. The animals were submitted to the same behavioral and biochemical tests described in Part 1. Part 3: Was compared serum CK levels between BD patients, in the various phases (depressive, manic, and euthymic), and healthy volunteers. In the first part of the study was demonstrated that d-AMPH and m-AMPH (all doses administered) increased locomotor activity of animals. The numbers of visits to the centre were increased by d-AMPH and m-AMPH at 2 mg/kg. The m-AMPH administration at 2mg/kg increased the amount of stereotypic behavior. The amphetamines significantly decreased the activities of Krebs cycle enzymes, mitochondrial respiratory chain complexes and CK; nevertheless, this effect varied depending on the brain region evaluated. In the second part of this study we found that Li and VPA reversed m-AMPH-induced hyperactivity. Besides, Li and VPA reversed m-AMPH-induced energetic metabolism dysfunction; however, the effects of Li and VPA were dependent on the brain region analyzed. Finally, in the third part of this study was demonstrated that CK levels were higher in the manic patients than in the controls. Together these data show that: 1) at high doses, m-AMPH increased stereotyped (sniffing) behavior in rats, but d-AMPH did not. However, this study shows that d-AMPH and m-AMPH seem to have similar effects on the brains energetic metabolism; and the d-AMPH, m-AMPH is able to induced hyperactivity and energetic metabolism dysfunction, both seen in BD. In addition, Li and VPA reversed m-AMPH’s effects on locomotor activity and energetic metabolism. The clinical differences among the depressive, manic, and euthymic phases of BD are paralleled by contrasting levels of CK. However, further studies are needed in order to understand the state-dependent differences observed in serum CK activity. / O modelo animal de mania induzido por dextroanfetamina (d-AMPH) é descrito na literatura como um bom modelo animal de transtorno bipolar (TB). Entretanto, tem sido relatado diferenças entre os tipos de anfetaminas em induzir alterações comportamentais e neuroquímicas. Além disso, vários estudos sugerem que o TB está associado à disfunções no metabolismo energético. No presente estudo foi avaliado a diferença entre d-AMPH e metanfetamina (m-AMPH) sobre o comportamento e disfunção no metabolismo energético no cérebro de ratos. Foi avaliado também os efeitos de lítio (Li) e valproato (VPA) sobre as alterações comportamentais e sobre metabolismo energético induzidos por m-AMPH. Finalmente, comparamos os níveis de creatina quinase (CK) no soro de pacientes bipolares nas fases depressiva, maníaca e eutímica. Para tanto, o trabalho foi dividido em três partes. Parte 1: Ratos Wistar receberam uma injeção intraperitoneal (i.p) de salina, d-AMPH (2mg/kg) ou m-AMPH (0,25, 0,5, 1 ou 2mg/kg) e foram submetidos ao teste do campo aberto para avaliação comportamental 2 h após. Foi avaliada também a atividade das enzimas do ciclo de Krebs (citrato sintase, succinato desidrogenase e malato desidrogenase), dos complexos da cadeia respiratória mitocondrial (I, II, II-III, IV) e da CK no cérebro dos ratos. Parte 2: Foi administrado m-AMPH ou salina i.p em ratos Wistar durante 14 dias e entre o 8º e o 14º dia os animais eram tratados com Li, VPA ou salina via i.p. Os animais foram submetidos aos mesmos testes comportamentais e bioquímicos descritos na Parte1. Parte 3: Foram avaliados os níveis de CK no soro de pacientes bipolares - eutímicos, depressivos e em mania – que foram comparados com voluntários saudáveis. Na primeira parte do trabalho foi demonstrado que d-AMPH e m-AMPH aumentaram a atividade locomotora nos ratos. As visitas ao centro do campo aberto aumentaram com a administração de ambas as drogas na dose de 2mg/kg. A administração de m-AMPH na dose de 2mg/kg aumentou o comportamento estereotipado dos animais (sniffing). A administração tanto de d-AMPH quanto de m-AMPH diminuiu a atividade das enzimas do ciclo de Krebs, dos complexos da cadeia respiratória mitocondrial e da CK; entretanto, estes efeitos variam de acordo com a região cerebral avaliada. Na segunda parte do trabalho foi demonstrado que Li e VPA revertem a hiperatividade e alterações no metabolismo energético induzida por m-AMPH. Por fim, na terceira parte do trabalho foi demonstrado que durante a mania, os níveis de CK estão aumentados no soro dos pacientes bipolares quando comparado com voluntários saudáveis. Estes dados demonstram que a m-AMPH, mas não d-AMPH, induz comportamento estereotípico em ratos; porém, as duas drogas parecem ter efeitos similares sobre o metabolismo energético; e que, assim como a d-AMPH, a m-AMPH é capaz de induzir hiperatividade e disfunção no metabolismo energético que são revertidos por Li e VPA. As fases maníaca, depressiva e eutímica do TB, além de apresentarem sintomatologia distinta, também podem ser diferenciadas pelo nível de CK presente no soro dos pacientes. Entretanto, mais estudos são necessários para entender as diferenças observadas na atividade da CK durante as fases do TB.
3

Determinação de estimulantes anfetamínicos no fluido oral : especificidade dos métodos de triagem e análise confirmatória

Souza, Daniele Zago January 2010 (has links)
O Brasil destaca-se no cenário mundial em relação ao consumo de estimulantes anfetamínicos (ATS), e estudos nacionais têm evidenciado grande prevalência na utilização destas substâncias por motoristas profissionais. O fluido oral apresenta uma série de vantagens sobre as matrizes tradicionais para a monitorização do consumo de ATS no trânsito, e vem sendo empregada em diversos países. Este trabalho objetivou avaliar a especificidade de imunoensaios comerciais na detecção preliminar dos ATS comercializados no Brasil em amostras de fluído oral e desenvolver e validar um método para a confirmação e quantificação de anfetamina (AMP), metanfetamina (MET), anfepramona (DIE), fenproporex (FEN) e metilfenidato (MPH) no fluído oral por microextração em fase sólida (SPME) e cromatografia a gás com detector de massas (CG/EM). A especificidade analítica dos imunoensaios foi avaliada por meio do estudo das informações técnicas de diversos produtos e da realização de ensaios experimentais com três testes. O método confirmatório por SPME-CG/EM foi desenvolvido a partir da técnica de imersão (DI-SPME), sob agitação magnética, à temperatura ambiente, utilizando fibras revestida por polidimetilsiloxano (30 μm), propilcloroformato como agente derivatizante e adição de Na2CO3 e de Na2SO4 para aumentar o pH e a força iônica do meio, respectivamente. Os testes imunológicos atualmente disponíveis para a triagem de ATS em fluido oral são importados e não detectam, mesmo em altas concentrações, os principais ATS consumidos no Brasil: FEN, DIE e MPH. O método por SPME-CG/EM foi linear para os ATS estudados no intervalo de 2-256 ng.mL-1, exceto para o FEN cujo intervalo foi de 4-256 ng.mL-1. Os limites de detecção foram 0,5 ng.mL-1 (MET), 1 ng.mL-1 (MPH) e 2 ng.mL-1 (DIE, AMP, FEN). A exatidão do método situou-se entre 98,2 – 111,9% e a precisão não excedeu 15% de desvio padrão relativo. O método foi aplicado com sucesso na estimação do perfil farmacocinético do FEN e da AMP no fluído oral de seis indivíduos do sexo masculino, após a administração de dose única de especialidade farmacêutica nacional contendo 25 mg de cloridrato de FEN. / The Brazil stands out on the world as a major consumer of amphetamine-type stimulants (ATS), and several national studies have shown high prevalence in the consumption of these substances by professional drivers. Oral fluid has many advantages over the conventional biological fluids for monitoring ATS use on roads, and has been employed with this purpose in several countries. The aim of this study is to assess the specificity/cross-reactivity of commercial oral fluid immunoassays in detecting the prescription ATS marketed in Brazil and to develop and validate a method for confirmation and quantification of amphetamine (AMP), methamphetamine (MET), amfepramone (DIE), fenproporex (FEN) and methylphenidate (MPH) in oral fluid by solid phase microextraction (SPME) and gas chromatography-mass spectrometry (GC-MS). Analytical specificity of immunoassays was evaluated through the study of the technical information of commercial products and through experimental testing of three kits. The confirmatory SPME-GC-MS method employed SPME immersion technique (DI-SPME), under magnetic stirring, at room temperature, using polydimethylsiloxane (30 μm) fibers, in-matrix propylchloroformate derivatization, Na2CO3 and Na2SO4 to increase both pH and ionic strength. Immunological tests currently available for ATS screening in oral fluid are imported and do not detect, even at high concentrations, the main ATS consumed in Brazil: FEN, MPH and DIE. The SPME-GC-MS method was linear for the studied ATS over the range of 2-256 ng.mL-1, except for FEN where the linear range was 4-256 ng.mL-1. The detection limits were 0.5 ng.mL-1 (MET), 1 ng.mL-1 (MPH) and 2 ng.mL-1 (DIE, AMP, FEN). Accuracy was within 98.2 – 111.9% of the target concentrations and precision did not exceed 15% of relative standard deviation. The method was successfully applied to estimate the pharmacokinetic profile of FEN and AMP in oral fluid of six male subjects after administration of a single dose of 25 mg FEN hydrochloride.
4

Fatores envolvidos no desenvolvimento e expressão da sensibilização comportamental ao efeito estimulante do modafinil e metanfetamina / Factors involved in development and expression of modafinil and methamphetamine-induced behavioral sensitization

Soeiro, Aline da Costa [UNIFESP] 28 April 2010 (has links) (PDF)
Made available in DSpace on 2015-07-22T20:50:14Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-04-28 / Associação Fundo de Incentivo à Psicofarmacologia (AFIP) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / A sensibilização comportamental refere-se ao aumento progressivo do efeito estimulante induzido após repetidas administrações de drogas de abuso como cocaína e anfetaminas. Estudos prévios sugerem que o ambiente pareado aos efeitos destas drogas parece ter um importante envolvimento no fenômeno da sensibilização comportamental. Além disso, o tratamento com uma droga de abuso pode interferir com a resposta comportamental eliciada por outra, quando essas possuirem algum mecanismo de ação comum. O presente estudo teve como objetivo investigar o envolvimento da aprendizagem contextual no fenômeno da sensibilização comportamental induzida pelo modafinil e metanfetamina e se haveria uma sensibilização cruzada entre as duas drogas. Os animais foram treinados e testados na tarefa do condicionamento de medo ao contexto (CMC). Após 15 dias foi realizado o teste da novidade, sem nenhuma manipulação farmacológica, às caixas de atividade locomotora. Para avaliar o desenvolvimento da sensibilização comportamental, após 24 horas do teste da novidade grupos diferentes de animais receberam injeções diárias de modafinil (50mg/kg) ou veículo (Experimento 2) e metanfetamina (1mg/kg) ou salina (Experimento 3) via ip por 10 dias e a atividade locomotora foi registrada nos dias 1, 5 e 10. Para avaliar a expressão da sensibilização comportamental, todos os animais foram desafiados com veículo e modafinil (50mg/kg - Experimento 2) e salina e metanfetamina (1mg/kg - Experimento 3) nas caixas de atividade e no campo aberto. No teste de sensibilização cruzada animais pré-tratados com veículo e modafinil receberam uma dose aguda de metanfetamina (Experimento 2) e animais pré-tratados com salina e metanfetamina receberam uma dose aguda de modafinil (Experimento 3). Em ambos os experimentos foi verificado um aumento progressivo na atividade locomotora e uma evidente diferença individual nos níveis de sensibilização comportamental entre os animais tratados com as drogas. Nos experimentos 2 e 3, todos os animais apresentaram resposta similar de tempo de congelamento no teste CMC. A expressão da sensibilização ao modafinil foi observada no ambiente previamente pareado com as administrações e foi bloqueada no ambiente não pareado. No caso da metanfetamina a expressão ocorreu em ambos ambientes. Também foi observado sensibilização cruzada simétrica entre modafinil e metanfetamina. Os resultados do presente estudo apontam para um envolvimento da aprendizagem contextual na sensibilização comportamental, porém parece não ser generalizado para todas as drogas psicoestimulantes. Além disso, apontam que existe uma grande variabilidade individual ao desenvolvimento da sensibilização comportamental ao modafinil e à metanfetamina. Ainda pode-se sugerir que exista um mecanismo similar de ação entre o modafinil e a metanfetamina. / The behavioral sensitization refers to the progressive increase of the stimulatory effect induced by repeated administration of drugs of abuse such as cocaine and amphetamine. Previous studies suggest that the environment paired with the drug stimulant effect of those drugs has an important role in the behavioral sensitization phenomena. Besides, the chronic treatment with one drug of abuse can induce a different patter of response to the administration of other drug indicating that both drug share some similar mechanism of action. The present study aimed to investigate the involvement of contextual learning in the modafinil and methamphetamine behavioral sensitization phenomena and if there is cross-sensitization between the two drugs. Fifteen days after the contextual fear conditioning task, mice received repeated administration of vehicle or modafinil (50mg/kg - Experiment 2) and saline or methamphetamine (1mg/kg - Experiment 3) for 10 days; they were tested in activity cages on days 1, 5 and 10. To evaluate the expression of behavioral sensitization the mice were challenged with vehicle or modafinil (50mg/kg - Experiment 2) and saline or methamphetamine (1 mg/kg - Experiment 3) and then they were tested in the activity cages and in the open field arena. For cross-sensitization test, mice from Experiment 2 were challenged with saline and methamphetamine (1mg/kg) and those mice from Experiment 3 were challenged with vehicle and modafinil (50mg/kg). In both experiments we did not find any correlation between the levels of freezing in the contextual fear conditioning task and different levels of sensitization. Modafinil-sensitized subgroup of mice expressed clear behavioral sensitization in the activity cage, but not in the open field, suggesting a context-dependent expression of modafinil sensitization. We also observed a symmetric cross-sensitization between modafinil and methamphetamine. Our findings indicate that there are a important individual variability to the development of behavioral sensitization to methamphetamine and to modafinil. Besides, we suggest that modafinil and methamphetamine seem to share similar mechanisms of action. / FAPESP: 08/56049-0 / TEDE / BV UNIFESP: Teses e dissertações
5

Determinação de estimulantes anfetamínicos no fluido oral : especificidade dos métodos de triagem e análise confirmatória

Souza, Daniele Zago January 2010 (has links)
O Brasil destaca-se no cenário mundial em relação ao consumo de estimulantes anfetamínicos (ATS), e estudos nacionais têm evidenciado grande prevalência na utilização destas substâncias por motoristas profissionais. O fluido oral apresenta uma série de vantagens sobre as matrizes tradicionais para a monitorização do consumo de ATS no trânsito, e vem sendo empregada em diversos países. Este trabalho objetivou avaliar a especificidade de imunoensaios comerciais na detecção preliminar dos ATS comercializados no Brasil em amostras de fluído oral e desenvolver e validar um método para a confirmação e quantificação de anfetamina (AMP), metanfetamina (MET), anfepramona (DIE), fenproporex (FEN) e metilfenidato (MPH) no fluído oral por microextração em fase sólida (SPME) e cromatografia a gás com detector de massas (CG/EM). A especificidade analítica dos imunoensaios foi avaliada por meio do estudo das informações técnicas de diversos produtos e da realização de ensaios experimentais com três testes. O método confirmatório por SPME-CG/EM foi desenvolvido a partir da técnica de imersão (DI-SPME), sob agitação magnética, à temperatura ambiente, utilizando fibras revestida por polidimetilsiloxano (30 μm), propilcloroformato como agente derivatizante e adição de Na2CO3 e de Na2SO4 para aumentar o pH e a força iônica do meio, respectivamente. Os testes imunológicos atualmente disponíveis para a triagem de ATS em fluido oral são importados e não detectam, mesmo em altas concentrações, os principais ATS consumidos no Brasil: FEN, DIE e MPH. O método por SPME-CG/EM foi linear para os ATS estudados no intervalo de 2-256 ng.mL-1, exceto para o FEN cujo intervalo foi de 4-256 ng.mL-1. Os limites de detecção foram 0,5 ng.mL-1 (MET), 1 ng.mL-1 (MPH) e 2 ng.mL-1 (DIE, AMP, FEN). A exatidão do método situou-se entre 98,2 – 111,9% e a precisão não excedeu 15% de desvio padrão relativo. O método foi aplicado com sucesso na estimação do perfil farmacocinético do FEN e da AMP no fluído oral de seis indivíduos do sexo masculino, após a administração de dose única de especialidade farmacêutica nacional contendo 25 mg de cloridrato de FEN. / The Brazil stands out on the world as a major consumer of amphetamine-type stimulants (ATS), and several national studies have shown high prevalence in the consumption of these substances by professional drivers. Oral fluid has many advantages over the conventional biological fluids for monitoring ATS use on roads, and has been employed with this purpose in several countries. The aim of this study is to assess the specificity/cross-reactivity of commercial oral fluid immunoassays in detecting the prescription ATS marketed in Brazil and to develop and validate a method for confirmation and quantification of amphetamine (AMP), methamphetamine (MET), amfepramone (DIE), fenproporex (FEN) and methylphenidate (MPH) in oral fluid by solid phase microextraction (SPME) and gas chromatography-mass spectrometry (GC-MS). Analytical specificity of immunoassays was evaluated through the study of the technical information of commercial products and through experimental testing of three kits. The confirmatory SPME-GC-MS method employed SPME immersion technique (DI-SPME), under magnetic stirring, at room temperature, using polydimethylsiloxane (30 μm) fibers, in-matrix propylchloroformate derivatization, Na2CO3 and Na2SO4 to increase both pH and ionic strength. Immunological tests currently available for ATS screening in oral fluid are imported and do not detect, even at high concentrations, the main ATS consumed in Brazil: FEN, MPH and DIE. The SPME-GC-MS method was linear for the studied ATS over the range of 2-256 ng.mL-1, except for FEN where the linear range was 4-256 ng.mL-1. The detection limits were 0.5 ng.mL-1 (MET), 1 ng.mL-1 (MPH) and 2 ng.mL-1 (DIE, AMP, FEN). Accuracy was within 98.2 – 111.9% of the target concentrations and precision did not exceed 15% of relative standard deviation. The method was successfully applied to estimate the pharmacokinetic profile of FEN and AMP in oral fluid of six male subjects after administration of a single dose of 25 mg FEN hydrochloride.
6

Determinação de estimulantes anfetamínicos no fluido oral : especificidade dos métodos de triagem e análise confirmatória

Souza, Daniele Zago January 2010 (has links)
O Brasil destaca-se no cenário mundial em relação ao consumo de estimulantes anfetamínicos (ATS), e estudos nacionais têm evidenciado grande prevalência na utilização destas substâncias por motoristas profissionais. O fluido oral apresenta uma série de vantagens sobre as matrizes tradicionais para a monitorização do consumo de ATS no trânsito, e vem sendo empregada em diversos países. Este trabalho objetivou avaliar a especificidade de imunoensaios comerciais na detecção preliminar dos ATS comercializados no Brasil em amostras de fluído oral e desenvolver e validar um método para a confirmação e quantificação de anfetamina (AMP), metanfetamina (MET), anfepramona (DIE), fenproporex (FEN) e metilfenidato (MPH) no fluído oral por microextração em fase sólida (SPME) e cromatografia a gás com detector de massas (CG/EM). A especificidade analítica dos imunoensaios foi avaliada por meio do estudo das informações técnicas de diversos produtos e da realização de ensaios experimentais com três testes. O método confirmatório por SPME-CG/EM foi desenvolvido a partir da técnica de imersão (DI-SPME), sob agitação magnética, à temperatura ambiente, utilizando fibras revestida por polidimetilsiloxano (30 μm), propilcloroformato como agente derivatizante e adição de Na2CO3 e de Na2SO4 para aumentar o pH e a força iônica do meio, respectivamente. Os testes imunológicos atualmente disponíveis para a triagem de ATS em fluido oral são importados e não detectam, mesmo em altas concentrações, os principais ATS consumidos no Brasil: FEN, DIE e MPH. O método por SPME-CG/EM foi linear para os ATS estudados no intervalo de 2-256 ng.mL-1, exceto para o FEN cujo intervalo foi de 4-256 ng.mL-1. Os limites de detecção foram 0,5 ng.mL-1 (MET), 1 ng.mL-1 (MPH) e 2 ng.mL-1 (DIE, AMP, FEN). A exatidão do método situou-se entre 98,2 – 111,9% e a precisão não excedeu 15% de desvio padrão relativo. O método foi aplicado com sucesso na estimação do perfil farmacocinético do FEN e da AMP no fluído oral de seis indivíduos do sexo masculino, após a administração de dose única de especialidade farmacêutica nacional contendo 25 mg de cloridrato de FEN. / The Brazil stands out on the world as a major consumer of amphetamine-type stimulants (ATS), and several national studies have shown high prevalence in the consumption of these substances by professional drivers. Oral fluid has many advantages over the conventional biological fluids for monitoring ATS use on roads, and has been employed with this purpose in several countries. The aim of this study is to assess the specificity/cross-reactivity of commercial oral fluid immunoassays in detecting the prescription ATS marketed in Brazil and to develop and validate a method for confirmation and quantification of amphetamine (AMP), methamphetamine (MET), amfepramone (DIE), fenproporex (FEN) and methylphenidate (MPH) in oral fluid by solid phase microextraction (SPME) and gas chromatography-mass spectrometry (GC-MS). Analytical specificity of immunoassays was evaluated through the study of the technical information of commercial products and through experimental testing of three kits. The confirmatory SPME-GC-MS method employed SPME immersion technique (DI-SPME), under magnetic stirring, at room temperature, using polydimethylsiloxane (30 μm) fibers, in-matrix propylchloroformate derivatization, Na2CO3 and Na2SO4 to increase both pH and ionic strength. Immunological tests currently available for ATS screening in oral fluid are imported and do not detect, even at high concentrations, the main ATS consumed in Brazil: FEN, MPH and DIE. The SPME-GC-MS method was linear for the studied ATS over the range of 2-256 ng.mL-1, except for FEN where the linear range was 4-256 ng.mL-1. The detection limits were 0.5 ng.mL-1 (MET), 1 ng.mL-1 (MPH) and 2 ng.mL-1 (DIE, AMP, FEN). Accuracy was within 98.2 – 111.9% of the target concentrations and precision did not exceed 15% of relative standard deviation. The method was successfully applied to estimate the pharmacokinetic profile of FEN and AMP in oral fluid of six male subjects after administration of a single dose of 25 mg FEN hydrochloride.

Page generated in 0.0856 seconds