• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 13
  • Tagged with
  • 13
  • 13
  • 13
  • 13
  • 13
  • 13
  • 13
  • 13
  • 13
  • 13
  • 13
  • 11
  • 11
  • 11
  • 11
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Correlação entre o eletrorretinograma de padrão reverso, a tomografia de coerência óptica e a perimetria automatizada na detecção da perda neural na atrofia em banda do nervo óptico / Relationship between pattern electroretinogram, optical coherence tomography and automated perimetry for detection of neural loss in eyes with band atrophy of the optic nerve

Cunha, Leonardo Provetti 09 August 2010 (has links)
OBJETIVO: Avaliar a capacidade dos parâmetros do eletrorretinograma de padrão reverso de campo total e hemianópico em diferenciar olhos com atrofia em banda do nervo óptico e, a correlação entre as amplitudes do eletrorretinograma de padrão reverso, a espessura da camada de fibras nervosas da retina e macular obtidas pela tomografia de coerência óptica e a perda de campo visual nestes pacientes. MÉTODOS: Quarenta e um olhos de 41 pacientes com perda de campo visual temporal permanente por compressão do quiasma óptico e 41 controles normais foram submetidos ao eletrorretinograma de padrão reverso de estimulação de campo total e hemianópicos (temporal e nasal), a tomografia de coerência óptica, para avaliação das medidas da espessura da camada de fibras nervosas da retina e macular e, ao exame de campo visual, pela perimetria automatizada padrão. O desvio do normal da sensibilidade dos 18º centrais do campo visual foram expressos em decibéis e unidades 1/Lambert. As comparações foram feitas pelo teste t de Student. A correlação entre os parâmetros do campo visual central, do eletrorretinograma de padrão reverso e da tomografia de coerência óptica foi avaliada pela correlação de Pearson e análise de regressão linear. RESULTADOS: Os valores das amplitudes P50, N95, and P50+N95 do eletrorretinograma de padrão reverso de campo total, e de estimulação hemianópica e os valores das medidas da espessura macular e da camada de fibras nervosas da retina obtidas pela tomografia de coerência óptica foram significativamente menores nos olhos com atrofia em banda do que nos controles (P<0,001). Uma correlação significativa foi encontrada entre a perda de sensibilidade no campo visual central e as amplitudes do eletrorretinograma de padrão reverso de estimulação de campo total e nasal, mas não para o temporal. Uma correlação significativa positiva foi observada entre os parâmetros de perda de sensibilidade no campo visual e a maioria dos parâmetros da espessura da camada de fibras nervosas da retina e macular obtidas pela tomografia de coerência óptica. Nenhuma correlação significativa foi observada entre os parâmetros do eletrorretinograma de padrão reverso e a tomografia de coerência óptica, exceto para amplitude P50+N95 do eletrorretinograma de padrão reverso de estimulação de hemicampo nasal. Uma correlação significativa foi observada entre os parâmetros de espessura macular e da camada de fibras nervosas pela tomografia de coerência óptica, exceto entre a espessura da camada de fibras nervosas no segmento de 30º, correspondente as 9 horas do relógio e os parâmetros maculares. CONCLUSÕES: Os valores das amplitudes do eletrorretinograma de padrão reverso foram eficazes em diferenciar olhos com atrofia em banda do nervo óptico de controles normais. Em pacientes com atrofia em banda do nervo óptico, as amplitudes do eletrorretinograma de padrão reverso e medidas da espessura da camada de fibras nervosas da retina e macular correlacionaram de forma significativa com a perda de campo visual, mas não houve correlação entre eles. O eletrorretinograma de padrão reverso e a tomografia de coerência óptica detectaram a perda neural e ambos são métodos diagnósticos úteis na compreensão da correlação estrutura-função em pacientes com compressão do quiasma óptico / PURPOSE: To evaluate the ability of full-field and hemifield pattern electroretinogram parameters to differentiate between healthy eyes and eyes with band atrophy of the optic nerve and also to evaluate the relationship between pattern electroretinogram amplitude, macular and retinal nerve fiber layer thickness by optical coherence tomography, and visual field loss on standard automated perimetry in eyes with BA of optic nerve. METHODS: Forty-one eyes from 41 patients with permanent temporal visual field defects from chiasmal compression and 41 healthy subjects underwent transient fullfield and hemifield (temporal or nasal) stimulation pattern electroretinogram, standard automated perimetry and time domain- optical coherence tomography macular and retinal nerve fiber layer thickness measurements. Comparisons were made using Students t-test. Deviation from normal visual field sensitivity for the central 18° was expressed in dB and 1/Lambert units. Correlations between measurements were verified by Pearsons correlations and linear regression analysis. RESULTS: Full-field P50, N95, and P50+N95 amplitude values were significantly smaller in eyes with band atrophy than in control eyes (P<0.001). Nasal and temporal hemifield pattern electroretinogram studies revealed significant differences in N95 and P50+N95 amplitudes measurements. Pattern electroretinogram and optical coherence tomography measurements were significantly lower in eyes with temporal hemianopia than in normal eyes. A significant correlation was found between visual field sensitivity loss and full-field or nasal, but not temporal, hemifield pattern electroretinogram amplitude. Likewise a significant correlation was found between visual field sensitivity loss and most optical coherence tomography parameters. No significant correlation was observed between optical coherence tomography and pattern electroretinogram parameters, except for nasal hemifield amplitude. A significant correlation was observed between several macular and retinal nerve fiber layer thickness parameters. CONCLUSIONS: Transient pattern electroretinogram amplitude measurements were efficient at differentiating eyes with band atrophy and permanent visual field defects from normal controls. In patients with chiasmal compression, pattern electroretinogram amplitude and optical coherence tomography thickness measurements were significant related to visual field loss, but not to each other. Pattern electroretinogram and optical coherence tomography quantify neuronal loss differently, but both technologies are useful in understanding structure-function relationship in patients with chiasmal compression
2

Correlação entre o eletrorretinograma de padrão reverso, a tomografia de coerência óptica e a perimetria automatizada na detecção da perda neural na atrofia em banda do nervo óptico / Relationship between pattern electroretinogram, optical coherence tomography and automated perimetry for detection of neural loss in eyes with band atrophy of the optic nerve

Leonardo Provetti Cunha 09 August 2010 (has links)
OBJETIVO: Avaliar a capacidade dos parâmetros do eletrorretinograma de padrão reverso de campo total e hemianópico em diferenciar olhos com atrofia em banda do nervo óptico e, a correlação entre as amplitudes do eletrorretinograma de padrão reverso, a espessura da camada de fibras nervosas da retina e macular obtidas pela tomografia de coerência óptica e a perda de campo visual nestes pacientes. MÉTODOS: Quarenta e um olhos de 41 pacientes com perda de campo visual temporal permanente por compressão do quiasma óptico e 41 controles normais foram submetidos ao eletrorretinograma de padrão reverso de estimulação de campo total e hemianópicos (temporal e nasal), a tomografia de coerência óptica, para avaliação das medidas da espessura da camada de fibras nervosas da retina e macular e, ao exame de campo visual, pela perimetria automatizada padrão. O desvio do normal da sensibilidade dos 18º centrais do campo visual foram expressos em decibéis e unidades 1/Lambert. As comparações foram feitas pelo teste t de Student. A correlação entre os parâmetros do campo visual central, do eletrorretinograma de padrão reverso e da tomografia de coerência óptica foi avaliada pela correlação de Pearson e análise de regressão linear. RESULTADOS: Os valores das amplitudes P50, N95, and P50+N95 do eletrorretinograma de padrão reverso de campo total, e de estimulação hemianópica e os valores das medidas da espessura macular e da camada de fibras nervosas da retina obtidas pela tomografia de coerência óptica foram significativamente menores nos olhos com atrofia em banda do que nos controles (P<0,001). Uma correlação significativa foi encontrada entre a perda de sensibilidade no campo visual central e as amplitudes do eletrorretinograma de padrão reverso de estimulação de campo total e nasal, mas não para o temporal. Uma correlação significativa positiva foi observada entre os parâmetros de perda de sensibilidade no campo visual e a maioria dos parâmetros da espessura da camada de fibras nervosas da retina e macular obtidas pela tomografia de coerência óptica. Nenhuma correlação significativa foi observada entre os parâmetros do eletrorretinograma de padrão reverso e a tomografia de coerência óptica, exceto para amplitude P50+N95 do eletrorretinograma de padrão reverso de estimulação de hemicampo nasal. Uma correlação significativa foi observada entre os parâmetros de espessura macular e da camada de fibras nervosas pela tomografia de coerência óptica, exceto entre a espessura da camada de fibras nervosas no segmento de 30º, correspondente as 9 horas do relógio e os parâmetros maculares. CONCLUSÕES: Os valores das amplitudes do eletrorretinograma de padrão reverso foram eficazes em diferenciar olhos com atrofia em banda do nervo óptico de controles normais. Em pacientes com atrofia em banda do nervo óptico, as amplitudes do eletrorretinograma de padrão reverso e medidas da espessura da camada de fibras nervosas da retina e macular correlacionaram de forma significativa com a perda de campo visual, mas não houve correlação entre eles. O eletrorretinograma de padrão reverso e a tomografia de coerência óptica detectaram a perda neural e ambos são métodos diagnósticos úteis na compreensão da correlação estrutura-função em pacientes com compressão do quiasma óptico / PURPOSE: To evaluate the ability of full-field and hemifield pattern electroretinogram parameters to differentiate between healthy eyes and eyes with band atrophy of the optic nerve and also to evaluate the relationship between pattern electroretinogram amplitude, macular and retinal nerve fiber layer thickness by optical coherence tomography, and visual field loss on standard automated perimetry in eyes with BA of optic nerve. METHODS: Forty-one eyes from 41 patients with permanent temporal visual field defects from chiasmal compression and 41 healthy subjects underwent transient fullfield and hemifield (temporal or nasal) stimulation pattern electroretinogram, standard automated perimetry and time domain- optical coherence tomography macular and retinal nerve fiber layer thickness measurements. Comparisons were made using Students t-test. Deviation from normal visual field sensitivity for the central 18° was expressed in dB and 1/Lambert units. Correlations between measurements were verified by Pearsons correlations and linear regression analysis. RESULTS: Full-field P50, N95, and P50+N95 amplitude values were significantly smaller in eyes with band atrophy than in control eyes (P<0.001). Nasal and temporal hemifield pattern electroretinogram studies revealed significant differences in N95 and P50+N95 amplitudes measurements. Pattern electroretinogram and optical coherence tomography measurements were significantly lower in eyes with temporal hemianopia than in normal eyes. A significant correlation was found between visual field sensitivity loss and full-field or nasal, but not temporal, hemifield pattern electroretinogram amplitude. Likewise a significant correlation was found between visual field sensitivity loss and most optical coherence tomography parameters. No significant correlation was observed between optical coherence tomography and pattern electroretinogram parameters, except for nasal hemifield amplitude. A significant correlation was observed between several macular and retinal nerve fiber layer thickness parameters. CONCLUSIONS: Transient pattern electroretinogram amplitude measurements were efficient at differentiating eyes with band atrophy and permanent visual field defects from normal controls. In patients with chiasmal compression, pattern electroretinogram amplitude and optical coherence tomography thickness measurements were significant related to visual field loss, but not to each other. Pattern electroretinogram and optical coherence tomography quantify neuronal loss differently, but both technologies are useful in understanding structure-function relationship in patients with chiasmal compression
3

Comparação de métodos de imagem do disco óptico e da camada de fibras nervosas da retina para o diagnóstico do glaucoma / Comparison of optic disc and retinal nerve fiber layer imaging methods for glaucoma diagnosis

Medeiros, Felipe de Araujo Andrade 02 June 2005 (has links)
Alterações no aspecto do disco óptico e da camada de fibras nervosas da retina (CFN) freqüentemente precedem o aparecimento de defeitos de campo visual no glaucoma, o que faz com que a avaliação destas estruturas seja essencial para o diagnóstico precoce e prevenção da perda visual nesta doença. A polarimetria de varredura a laser (GDx VCC), a oftalmoscopia confocal de varredura a laser (HRT II [Heidelberg Retina Tomograph]) e a tomografia de coerência óptica (Stratus OCT) são tecnologias que permitem a avaliação objetiva e quantitativa do disco óptico e da CFN. No presente estudo, estas tecnologias foram comparadas em sua habilidade para diferenciar pacientes glaucomatosos de indivíduos normais. Pacientes com glaucoma foram selecionados com base na presença de defeitos reprodutíveis de campo visual na perimetria acromática automatizada (glaucoma perimétrico), ou com base na evidência documentada de progressão do dano glaucomatoso ao disco óptico, sem presença de defeitos de campo visual (glaucoma pré-perimétrico). Indivíduos normais apresentaram campos visuais e exame clínico dentro da normalidade. Todos os indivíduos foram submetidos a exames com o GDx VCC, HRT II, Stratus OCT e campo visual dentro de um período de três meses. Diversas medidas foram utilizadas para avaliação da acurácia diagnóstica, incluindo áreas sob as curvas receiver operating characteristic (AROC), sensibilidades para especificidades fixas, e razões de probabilidade. Modelos estatísticos foram utilizados para avaliação da influência da severidade do glaucoma e tamanho do disco óptico na performance diagnóstica dos diferentes instrumentos. Um olho de cada indivíduo foi utilizado para análise. Dos 258 sujeitos inicialmente avaliados, 33 (13%) foram posteriormente excluídos por apresentarem imagens de baixa qualidade em pelo menos um dos aparelhos, restando 225 indivíduos (133 glaucomatosos e 92 normais) para análise. Na comparação entre os parâmetros de cada instrumento com maiores valores de AROC, o parâmetro do GDx VCC, Nerve Fiber Indicator (NFI; AROC = 0,91), e o parâmetro do Stratus OCT, Espessura Média (AROC = 0,90), apresentaram áreas sob as curvas ROC significativamente superiores à do parâmetro do HRT II, função discriminante de Bathija (AROC = 0,84). A severidade do defeito de campo visual exerceu influência significativa sob a acurácia diagnóstica dos três instrumentos, com melhora no poder diagnóstico em casos mais avançados da doença. Para o GDx VCC e Stratus OCT, o aumento no tamanho do disco óptico foi associado à diminuição na sensibilidade para detecção do glaucoma; enquanto que, para o HRT II, diminuição no tamanho do disco óptico foi associada à diminuição na sensibilidade. Razões de probabilidade para resultados anormais nas xxv classificações finais de cada instrumento foram associadas a grandes efeitos de mudança na probabilidade pós-teste em relação à probabilidade préteste, sugerindo que o encontro de um resultado anormal em qualquer um destes testes, durante a avaliação de um paciente com suspeita de glaucoma, tem impacto significativo em aumentar a probabilidade de que a doença esteja presente. Além disso, os resultados obtidos na avaliação de pacientes com glaucoma pré-perimétrico sugerem que todos os três instrumentos sejam capazes de detectar alterações estruturais precoces no glaucoma, antes do aparecimento de defeitos de campo visual na perimetria acromática / Changes in the structural appearance of the optic nerve head (ONH) and retinal nerve fiber layer (RNFL) have been reported to precede the development of visual field loss in glaucoma. Detection of ONH and RNFL damage is therefore crucial for early diagnosis of glaucoma and prevention of functional loss from the disease. Scanning laser polarimetry (GDx VCC), confocal scanning laser ophthalmoscopy (HRT II [Heidelberg Retina Tomograph]) and optical coherence tomography (Stratus OCT) are different technologies capable of providing objective and quantitative information related to these structures. The purpose of the present study was to compare, in a single population, the diagnostic abilities of these technologies in the discrimination of glaucomatous patients from healthy subjects. Glaucoma patients were selected based on the presence of repeatable visual field defects, as identified by standard automated perimetry (perimetric glaucoma), or documented evidence of progressive damage to the optic disc, in the absence of detectable visual field loss (preperimetric glaucoma). Normal subjects had normal visual fields and normal clinical examination. All subjects underwent imaging with the GDx VCC, HRT II and Stratus OCT within a 3-month period. Several measures were used for evaluation of diagnostic accuracy, including the area under the receiver operating characteristic curve (AROC), sensitivities at fixed specifities, and likelihood ratios. Statistical models were used to evaluate the influence of glaucoma severity and optic disc size on the diagnostic performance of the different instruments. One eye of each individual was randomly selected for statistical analysis. From an initial group of 258 eligible subjects, 33 (13%) had images of unacceptable quality, leaving 133 glaucoma patients and 92 healthy subjects for further analysis. In the comparison of the parameters with highest values of AROC from each instrument, the GDx VCC Nerve Fiber Indicator (AROC = 0.91) and the Stratus OCT Average Thickness (AROC = 0.90) perfomed significanlty better than the HRT II Bathija discriminant function (AROC = 0.84). For all instruments, the diagnostic accuracy increased with increasing severity of visual field defects. For the GDx VCC and Stratus OCT parameters, an increase in the size of the optic disc was related to a decrease in the sensitivity for glaucoma detection. An opposite effect was observed with the HRT II: a decrease in the size of the optic disc was related to a decrease in the sensitivity for glaucoma diagnosis. Abnormal results for each of the instruments were associated with strong positive likelihood ratios, indicating a large change from prestest to posttest probability of glaucoma. These results suggest that the finding of an abnormal result in any of these tests, when assessing a patient suspect of having glaucoma, would substantially raise the probability of disease. Results of the evaluation of patients with preperimetric glaucoma also suggest that all three instruments are able to detect early glaucomatous structural damage in the absence of visual field loss
4

Comparação das medidas da espessura macular e da camada de fibras nervosas retiniana para detecção de atrofia em banda do nervo óptico através da tomografia de coerência óptica / Comparison of macular thickness and retinal nerve fiber thickness measurements for detection of band atrophy of the optic nerve using optical coherence tomography

Moura, Frederico Castelo 31 August 2007 (has links)
Pacientes com compressão quiasmática apresentam perda das fibras nervosas da retina nasal que decussam no quiasma óptico. Por conseguinte, ocorre perda das fibras nervosas, predominantemente, no setor nasal e temporal do disco óptico, que se manifesta por atrofia em banda do nervo óptico ao exame oftalmoscópico e hemianopsia temporal ao exame de campo visual. Trabalhos anteriores mostraram que o tomógrafo de coerência óptica é capaz de diferenciar pacientes com atrofia em banda do nervo óptico associada à hemianopsia temporal completa de indivíduos normais através da análise da camada de fibras nervosas peripapilar. Estudos em glaucoma têm sugerido que a avaliação da espessura macular poderia ser útil na quantificação da perda neural como um método alternativo ou complementar ao estudo da camada de fibras nervosas da retina. No presente estudo, a espessura macular e da camada de fibras nervosas foram avaliadas pelo tomógrafo de coerência óptica em pacientes com atrofia em banda do nervo óptico e graus variados de hemianopsia temporal. O desempenho dos parâmetros maculares para detecção da atrofia em banda do nervo óptico foi avaliado pela área sob a curva ROC (AROC) e sensibilidades para especificidades fixas e os resultados foram comparados aos parâmetros da camada de fibras nervosas peripapilar. Para identificar os parâmetros do Stratus OCT que apresentaram melhor desempenho para diferenciar pacientes com AB do nervo óptico de indivíduos normais, modelos de regressão logística foram utilizados. A correlação estrutura-função foi realizada entre o grau do defeito temporal e os valores de espessura macular e da camada de fibras peripapilar através do coeficiente de correlação de Spearman. A categorização diagnóstica dos parâmetros da camada de fibras nervosas através do banco de dados normativos foi avaliada pelos valores de sensibilidade e especificidade calculados pelo teste exato de Fisher. Quarenta e quatro olhos com atrofia em banda e 47 olhos normais foram avaliados no estudo. Entre os parâmetros maculares, os parâmetros da retina nasal apresentaram melhor desempenho para detectar atrofia em banda do nervo óptico comparados aos parâmetros da retina temporal. Não houve diferença significante (p=0,32) entre as áreas sob a curva ROC do melhor parâmetro macular (AROC=0,97) e do melhor parâmetro da camada de fibras nervosas retiniana (AROC=0,99). Na avaliação da correlação estrutura-função, os parâmetros da retina nasal apresentaram maior correlação com o defeito campimétrico comparados aos parâmetros da camada de fibras nervosas da retinal. Entre os parâmetros maculares, a espessura nasal média apresentou a maior correlação (rs=0,618). Entre os parâmetros da camada de fibras nervosas da retina, a espessura média apresentou a maior correlação (rs=0,479). Os parâmetros espessura média, espessura nasal e espessura temporal da camada de fibras nervosas da retina apresentaram melhor desempenho diagnóstico baseado na categorização diagnóstica do banco de dados normativos. Os resultados obtidos no estudo mostraram que os parâmetros maculares discriminam olhos com atrofia em banda do nervo óptico em pacientes com graus variados de defeito temporal. Além disso, os parâmetros da retina nasal podem colaborar com o exame perimétrico e os parâmetros da camada de fibras nervosas para o seguimento dos pacientes com compressão quiasmática. / Patients with chiasmal compression present damage of crossed fibers of nasal retina. Therefore, retinal nerve fiber layer loss occurs predominantly on the nasal and temporal sides of the optic disc, a pattern that can be identified on ophthalmoscopy as band atrophy of the optic nerve and on visual field as temporal hemianopia. Previous studies have been demonstrated that optical coherence tomography is able to detect retinal nerve fiber layer loss in patients with lesions of the optic chiasm and complete temporal hemianopia. Studies in glaucoma have been suggested that macular thickness measurements could be useful in quantification of optical nerve axonal loss as alternative or complement method to evaluate the retinal nerve fiber layer. The purpose of the present study was to compare macular thickness and retinal nerve fiber thickness measurements in patients with band atrophy of the optic nerve and different severities of visual field defect using optical coherence tomography. Area under the receiver operating characteristic curve (AROC) and sensitivities at fixed specificities were performed for evaluation of diagnostic accuracy of macular and retinal nerve fiber layer parameters. To identify the best optical coherence tomography measurements to differentiate band atrophy of the optic nerve patients from normal individuals, logistic regression models were performed. Association between optical coherence tomography parameters and temporal field defect were examined by Spearman coefficient of correlation. Fisher\'s exact test was performed to evaluate diagnostic ability of retinal nerve fiber parameters by optical coherence tomography in eyes with band atrophy using comparison with its internal normative database. A total of 44 eyes with band atrophy of the optic nerve and 47 normal eyes were studied. Among macular parameters, nasal retina measurements showed diagnostic accuracy better than temporal retina measurements. No statistically significant difference (p=0.32) was found between areas under ROC curve for the best macular parameter (AROC=0.97) and the best retinal nerve fiber layer parameter (AROC=0.99). Nasal retina parameters correlations were higher than retinal nerve fiber parameters. The highest correlation was observed for the mean nasal thickness (rs=0.618) for macular parameters. In retinal nerve fiber parameters, the highest correlation was observed for the average thickness (rs=0.479). In evaluation of diagnostic ability of normative database, the average thickness parameter demonstrated the highest sensitivity for detection of abnormalities in eyes with band atrophy, followed by the parameters related to the nasal and temporal quadrants. These results suggest that macular thickness measurements discriminate eyes with band atrophy of the optic nerve with different severities of temporal field defect. Results also suggest that nasal retina thickness measurements could potentially be used to evaluate retinal ganglion cell loss in patients with chiasmal compression.
5

Potencial evocado visual multifocal em olhos com hemianopsia temporal por compressão quiasmática. Correlação com a perimetria computadorizada e a tomografia de coerência óptica / Multifocal visual evoked potential in eyes with temporal hemianopia from chiasmal compression. Correlation with standard automated perimetry and OCT findings

Sousa, Rafael Miranda 05 May 2017 (has links)
OBJETIVO: Avaliar a capacidade do potencial visual evocado multifocal (PEV-mf) em diferenciar pacientes portadores de hemianopsia temporal de controles normais e avaliar a correlação entre o PEV-mf, o campo visual (CV) realizado com a perimetria automatizada e a tomografia de coerência óptica de domínio fourier (TCO-dF). MÉTODOS: Vinte sete olhos de 21 pacientes com defeito de campo visual temporal secundário a compressão quiasmática e 43 olhos de 23 controles normais foram submetidos aos exames PEV-mf, CV e TCO-dF (3D OCT-1000®, Topcon) da mácula e da camada de fibras nervosas da retina (CFNR). Foi calculada a média das respostas do PEV-mf global, do PEV-mf central e a média de espessura do TCO-dF da mácula para cada quadrante e para cada hemicampo, enquanto a espessura da CFNR foi dividida em 12 setores ao redor do nervo óptico. A perda de CV foi calculada para os quatro quadrantes e para os hemicampos temporal e nasal no CV 24-2 e CV 10-2. Os dois grupos foram comparados utilizando equações de estimativas generalizadas (GEE) e as correlações entre o PEV-mf, CV e o TCO-dF foram calculadas. RESULTADOS: As médias das amplitude P1 e N2 do PEV-mf global e central para os hemicampos e os quadrantes temporais foram significativamente menores nos pacientes que nos controles (p < 0.004). Não houve diferença estatística entre os grupos para os parâmetros de amplitudes do PEV-mf nos setores nasais. Não houve diferença estatística nas médias das latências do PEV-mf global e central entre os pacientes e os controles normais. Foi encontrada correlação moderada, estatisticamente significativa, entre os parâmetros de amplitudes temporais do PEV-mf - global e central com a perda de CV 24-2 e 10-2 temporal, assim como com as medidas de espessura macular e da espessura CFNR na TCO-dF. CONCLUSÕES: As médias das amplitudes do PEV-mf foram capazes de diferenciar olhos de pacientes com hemianopsia dos controles normais e apresentaram correlação significativa com os dados obtidos pela perimetria automatizada e pelo TCO-dF. Estes dados sugerem que o PEV-mf global e central podem ser utilizados na detecção de anormalidades do campo visual em pacientes portadores de compressão quiasmática / PURPOSE: To evaluate the ability of multifocal visual evoked potential (mfVEP) to differentiate patients with temporal hemianopia due to chiasmal compression from normal controls. To assess the relationship between mfVEP, standard automated perimetry (SAP) and fourier domain-optical coherence tomography (fd-OCT). METHODS: Twenty-seven eyes of 21 patients with permanent temporal visual field (VF) defects from chiasmal compression and 43 eyes of 23 healthy controls underwent mfVEP, SAP and fd-OCT (3D OCT-1000®, Topcon) macular and peripapillary retinal nerve fiber layer (RNFL) measurements. It was averaged the responses for global mfVEP, central mfVEP and fd-OCT macular measurements were averaged in quadrants and halves, while peripapillary RNFL thickness was averaged in 12 sectors around the disc. VF loss was estimated in four quadrants and each half of 24-2 and 10-2 strategy test points. The two groups were compared using generalized estimated equations (GEE). Correlations between mfVEP, VF and fd-OCT findings were verified. RESULTS: Global and central mfVEP P1 and N2 amplitude parameters of temporal measurements were significantly smaller in patients than controls (p < 0.004). No significant differences were observed between the groups with respect to mfVEP amplitude parameters from the nasal measurements. No significant differences were observed in global and central mfVEP latency parameters for all averaged measurements between patients and healthy controls. A significant moderate correlation was found between global and central mfVEP amplitude parameters of temporal measurements and temporal VF 24-2 and 10-2 loss as well as with corresponding fd-OCT macular and RNFL thickness measurements. CONCLUSIONS: mfVEP amplitude parameters were able to differentiate eyes with temporal hemianopia from controls and were significant correlated with VF and fd-OCT findings. These data suggest that it is a useful technology for detecting visual abnormalities in patients with chiasmal compression
6

Comparação entre diversas técnicas de imagem para diagnóstico do glaucoma / Comparison of different imaging techniques to diagnose glaucoma

Vessani, Roberto Murad 20 March 2008 (has links)
O objetivo desse estudo foi comparar a habilidade da avaliação subjetiva do disco óptico e da camada de fibras nervosas (CFN) por oftalmologistas generalistas e por um glaucomatólogo com medidas objetivas pela tomografia de coerência óptica (Stratus OCT), oftalmoscopia confocal de varredura a laser (HRTIII), e a polarimetria de varredura a laser (GDxECC) para discriminar olhos glaucomatosos de olhos normais. 61 olhos glaucomatosos e 57 olhos normais de 118 indivíduos foram incluídos nesse estudo. Três oftalmologistas generalistas independentes e um glaucomatólogo avaliaram fotografias estereoscópicas do disco óptico. Curvas ROC (Receiver Operator Characteristic) foram construídas para cada técnica de imagem e a sensibilidade a uma especificidade fixa foi determinada. Comparações das áreas sob essas curvas (AROC) e a concordância (k) foram determinadas entre a graduação das fotografias estereoscópicas e o melhor parâmetro de cada exame de imagem computadorizado. O melhor parâmetro de cada técnica de imagem computadorizada (CFN temporal inferior do Stratus OCT = 0,92; área integrada vertical da topografia do disco óptico pelo Stratus OCT = 0,86; espessura macular do setor inferior externo fornecido pelo Stratus OCT = 0,82; NFI do GDxECC = 0,91; razão área E/D do HRT3 = 0,83) mostrou AROC maior do que a graduação das fotografias estereoscópicas por oftalmologistas generalistas (0,80) para separar olhos glaucomatosos de olhos normais. A graduação por glaucomatólogo forneceu AROC igual ou maior (0,92) do que o melhor parâmetro de exame computadorizado de imagem. A avaliação das fotografias estereoscópicas por glaucomatólogo mostrou melhor concordância com o melhor parâmetro de cada técnica de imagem quantitativa na classificação de olhos como glaucomatosos ou normais comparadas à avaliação de fotografias estereoscópicas por oftalmologistas generalistas. A combinação da avaliação subjetiva do disco óptico por oftalmologistas generalistas com parâmetros objetivos da CFN melhorou a identificação de olhos com glaucoma em uma proporção maior do que a combinação desses parâmetros objetivos com a avaliação do disco óptico por um glaucomatólogo (29,5% versus 19,7%, respectivamente). Os resultados sugerem que a habilidade diagnóstica de todos os exames de imagem computadorizados estudados mostrou melhor desempenho que a avaliação subjetiva do disco óptico por oftalmologistas generalistas, mas não por um glaucomatólogo. Medidas objetivas da CFN podem permitir um aperfeiçoamento na detecção de glaucoma quando combinados com a avaliação subjetiva do disco óptico por oftalmologistas generalistas ou por um glaucomatólogo. / The purpose of this study was to compare the ability of subjective assessment of optic nerve head and retinal nerve fiber layer by general ophthalmologists and by a glaucoma expert with objective measurements by optical coherence tomography (Stratus OCT, Carl Zeiss Meditec, Inc.), confocal scanning laser ophthalmoscope (HRT III; Heidelberg Engineering, Heidelberg, Germany), and scanning laser polarimetry (GDx ECC; Carl Zeiss Meditec, Inc., Dublin, CA) in discriminating glaucomatous and normal eyes. 61 glaucomatous and 57 normal eyes of 118 subjects were included in the study. Three independent general ophthalmologists and one glaucoma expert evaluated ONH stereophotographs. Receiver operating characteristic curves were constructed for each imaging technique and sensitivity at fixed specificity was estimated. Comparisons of areas under these curves (aROC) and agreement (k) were determined between stereophoto grading and best parameter from each technique. Best parameter from each technique showed larger aROC (StratusOCT RNFL = 0.92; StratusOCT ONH vertical integrated area = 0.86; StratusOCT macular thickness = 0.82; GDxECC = 0.91; HRT3 global cup-to-disc area ratio = 0.83) compared to stereophotograph grading by general ophthalmologists (0.80) in separating glaucomatous and normal eyes. Glaucoma expert stereophoto grading provided equal or larger aROC (0.92) than best parameter of each computerized imaging device. Stereophoto evaluated by a glaucoma expert showed better agreement with best parameter of each quantitative imaging technique in classifying eyes either as glaucomatous or normal compared to stereophoto grading by general ophthalmologists. The combination of subjective assessment of the optic disc by general ophthalmologists with RNFL objective parameters improved identification of glaucoma patients in a larger proportion than the combination of these objective parameters with subjective assessment of the optic disc by a glaucoma expert (29.5% versus 19.7%, respectively). The results suggests that the diagnostic ability of all imaging techniques showed better performance than subjective assessment of the ONH by general ophthalmologists, but not by a glaucoma expert. Objective RNFL measurements may provide improvement in glaucoma detection when combined with subjective assessment of the optic disc by general ophthalmologists or by a glaucoma expert.
7

Comparação das medidas da espessura macular e da camada de fibras nervosas retiniana para detecção de atrofia em banda do nervo óptico através da tomografia de coerência óptica / Comparison of macular thickness and retinal nerve fiber thickness measurements for detection of band atrophy of the optic nerve using optical coherence tomography

Frederico Castelo Moura 31 August 2007 (has links)
Pacientes com compressão quiasmática apresentam perda das fibras nervosas da retina nasal que decussam no quiasma óptico. Por conseguinte, ocorre perda das fibras nervosas, predominantemente, no setor nasal e temporal do disco óptico, que se manifesta por atrofia em banda do nervo óptico ao exame oftalmoscópico e hemianopsia temporal ao exame de campo visual. Trabalhos anteriores mostraram que o tomógrafo de coerência óptica é capaz de diferenciar pacientes com atrofia em banda do nervo óptico associada à hemianopsia temporal completa de indivíduos normais através da análise da camada de fibras nervosas peripapilar. Estudos em glaucoma têm sugerido que a avaliação da espessura macular poderia ser útil na quantificação da perda neural como um método alternativo ou complementar ao estudo da camada de fibras nervosas da retina. No presente estudo, a espessura macular e da camada de fibras nervosas foram avaliadas pelo tomógrafo de coerência óptica em pacientes com atrofia em banda do nervo óptico e graus variados de hemianopsia temporal. O desempenho dos parâmetros maculares para detecção da atrofia em banda do nervo óptico foi avaliado pela área sob a curva ROC (AROC) e sensibilidades para especificidades fixas e os resultados foram comparados aos parâmetros da camada de fibras nervosas peripapilar. Para identificar os parâmetros do Stratus OCT que apresentaram melhor desempenho para diferenciar pacientes com AB do nervo óptico de indivíduos normais, modelos de regressão logística foram utilizados. A correlação estrutura-função foi realizada entre o grau do defeito temporal e os valores de espessura macular e da camada de fibras peripapilar através do coeficiente de correlação de Spearman. A categorização diagnóstica dos parâmetros da camada de fibras nervosas através do banco de dados normativos foi avaliada pelos valores de sensibilidade e especificidade calculados pelo teste exato de Fisher. Quarenta e quatro olhos com atrofia em banda e 47 olhos normais foram avaliados no estudo. Entre os parâmetros maculares, os parâmetros da retina nasal apresentaram melhor desempenho para detectar atrofia em banda do nervo óptico comparados aos parâmetros da retina temporal. Não houve diferença significante (p=0,32) entre as áreas sob a curva ROC do melhor parâmetro macular (AROC=0,97) e do melhor parâmetro da camada de fibras nervosas retiniana (AROC=0,99). Na avaliação da correlação estrutura-função, os parâmetros da retina nasal apresentaram maior correlação com o defeito campimétrico comparados aos parâmetros da camada de fibras nervosas da retinal. Entre os parâmetros maculares, a espessura nasal média apresentou a maior correlação (rs=0,618). Entre os parâmetros da camada de fibras nervosas da retina, a espessura média apresentou a maior correlação (rs=0,479). Os parâmetros espessura média, espessura nasal e espessura temporal da camada de fibras nervosas da retina apresentaram melhor desempenho diagnóstico baseado na categorização diagnóstica do banco de dados normativos. Os resultados obtidos no estudo mostraram que os parâmetros maculares discriminam olhos com atrofia em banda do nervo óptico em pacientes com graus variados de defeito temporal. Além disso, os parâmetros da retina nasal podem colaborar com o exame perimétrico e os parâmetros da camada de fibras nervosas para o seguimento dos pacientes com compressão quiasmática. / Patients with chiasmal compression present damage of crossed fibers of nasal retina. Therefore, retinal nerve fiber layer loss occurs predominantly on the nasal and temporal sides of the optic disc, a pattern that can be identified on ophthalmoscopy as band atrophy of the optic nerve and on visual field as temporal hemianopia. Previous studies have been demonstrated that optical coherence tomography is able to detect retinal nerve fiber layer loss in patients with lesions of the optic chiasm and complete temporal hemianopia. Studies in glaucoma have been suggested that macular thickness measurements could be useful in quantification of optical nerve axonal loss as alternative or complement method to evaluate the retinal nerve fiber layer. The purpose of the present study was to compare macular thickness and retinal nerve fiber thickness measurements in patients with band atrophy of the optic nerve and different severities of visual field defect using optical coherence tomography. Area under the receiver operating characteristic curve (AROC) and sensitivities at fixed specificities were performed for evaluation of diagnostic accuracy of macular and retinal nerve fiber layer parameters. To identify the best optical coherence tomography measurements to differentiate band atrophy of the optic nerve patients from normal individuals, logistic regression models were performed. Association between optical coherence tomography parameters and temporal field defect were examined by Spearman coefficient of correlation. Fisher\'s exact test was performed to evaluate diagnostic ability of retinal nerve fiber parameters by optical coherence tomography in eyes with band atrophy using comparison with its internal normative database. A total of 44 eyes with band atrophy of the optic nerve and 47 normal eyes were studied. Among macular parameters, nasal retina measurements showed diagnostic accuracy better than temporal retina measurements. No statistically significant difference (p=0.32) was found between areas under ROC curve for the best macular parameter (AROC=0.97) and the best retinal nerve fiber layer parameter (AROC=0.99). Nasal retina parameters correlations were higher than retinal nerve fiber parameters. The highest correlation was observed for the mean nasal thickness (rs=0.618) for macular parameters. In retinal nerve fiber parameters, the highest correlation was observed for the average thickness (rs=0.479). In evaluation of diagnostic ability of normative database, the average thickness parameter demonstrated the highest sensitivity for detection of abnormalities in eyes with band atrophy, followed by the parameters related to the nasal and temporal quadrants. These results suggest that macular thickness measurements discriminate eyes with band atrophy of the optic nerve with different severities of temporal field defect. Results also suggest that nasal retina thickness measurements could potentially be used to evaluate retinal ganglion cell loss in patients with chiasmal compression.
8

Comparação de métodos de imagem do disco óptico e da camada de fibras nervosas da retina para o diagnóstico do glaucoma / Comparison of optic disc and retinal nerve fiber layer imaging methods for glaucoma diagnosis

Felipe de Araujo Andrade Medeiros 02 June 2005 (has links)
Alterações no aspecto do disco óptico e da camada de fibras nervosas da retina (CFN) freqüentemente precedem o aparecimento de defeitos de campo visual no glaucoma, o que faz com que a avaliação destas estruturas seja essencial para o diagnóstico precoce e prevenção da perda visual nesta doença. A polarimetria de varredura a laser (GDx VCC), a oftalmoscopia confocal de varredura a laser (HRT II [Heidelberg Retina Tomograph]) e a tomografia de coerência óptica (Stratus OCT) são tecnologias que permitem a avaliação objetiva e quantitativa do disco óptico e da CFN. No presente estudo, estas tecnologias foram comparadas em sua habilidade para diferenciar pacientes glaucomatosos de indivíduos normais. Pacientes com glaucoma foram selecionados com base na presença de defeitos reprodutíveis de campo visual na perimetria acromática automatizada (glaucoma perimétrico), ou com base na evidência documentada de progressão do dano glaucomatoso ao disco óptico, sem presença de defeitos de campo visual (glaucoma pré-perimétrico). Indivíduos normais apresentaram campos visuais e exame clínico dentro da normalidade. Todos os indivíduos foram submetidos a exames com o GDx VCC, HRT II, Stratus OCT e campo visual dentro de um período de três meses. Diversas medidas foram utilizadas para avaliação da acurácia diagnóstica, incluindo áreas sob as curvas receiver operating characteristic (AROC), sensibilidades para especificidades fixas, e razões de probabilidade. Modelos estatísticos foram utilizados para avaliação da influência da severidade do glaucoma e tamanho do disco óptico na performance diagnóstica dos diferentes instrumentos. Um olho de cada indivíduo foi utilizado para análise. Dos 258 sujeitos inicialmente avaliados, 33 (13%) foram posteriormente excluídos por apresentarem imagens de baixa qualidade em pelo menos um dos aparelhos, restando 225 indivíduos (133 glaucomatosos e 92 normais) para análise. Na comparação entre os parâmetros de cada instrumento com maiores valores de AROC, o parâmetro do GDx VCC, Nerve Fiber Indicator (NFI; AROC = 0,91), e o parâmetro do Stratus OCT, Espessura Média (AROC = 0,90), apresentaram áreas sob as curvas ROC significativamente superiores à do parâmetro do HRT II, função discriminante de Bathija (AROC = 0,84). A severidade do defeito de campo visual exerceu influência significativa sob a acurácia diagnóstica dos três instrumentos, com melhora no poder diagnóstico em casos mais avançados da doença. Para o GDx VCC e Stratus OCT, o aumento no tamanho do disco óptico foi associado à diminuição na sensibilidade para detecção do glaucoma; enquanto que, para o HRT II, diminuição no tamanho do disco óptico foi associada à diminuição na sensibilidade. Razões de probabilidade para resultados anormais nas xxv classificações finais de cada instrumento foram associadas a grandes efeitos de mudança na probabilidade pós-teste em relação à probabilidade préteste, sugerindo que o encontro de um resultado anormal em qualquer um destes testes, durante a avaliação de um paciente com suspeita de glaucoma, tem impacto significativo em aumentar a probabilidade de que a doença esteja presente. Além disso, os resultados obtidos na avaliação de pacientes com glaucoma pré-perimétrico sugerem que todos os três instrumentos sejam capazes de detectar alterações estruturais precoces no glaucoma, antes do aparecimento de defeitos de campo visual na perimetria acromática / Changes in the structural appearance of the optic nerve head (ONH) and retinal nerve fiber layer (RNFL) have been reported to precede the development of visual field loss in glaucoma. Detection of ONH and RNFL damage is therefore crucial for early diagnosis of glaucoma and prevention of functional loss from the disease. Scanning laser polarimetry (GDx VCC), confocal scanning laser ophthalmoscopy (HRT II [Heidelberg Retina Tomograph]) and optical coherence tomography (Stratus OCT) are different technologies capable of providing objective and quantitative information related to these structures. The purpose of the present study was to compare, in a single population, the diagnostic abilities of these technologies in the discrimination of glaucomatous patients from healthy subjects. Glaucoma patients were selected based on the presence of repeatable visual field defects, as identified by standard automated perimetry (perimetric glaucoma), or documented evidence of progressive damage to the optic disc, in the absence of detectable visual field loss (preperimetric glaucoma). Normal subjects had normal visual fields and normal clinical examination. All subjects underwent imaging with the GDx VCC, HRT II and Stratus OCT within a 3-month period. Several measures were used for evaluation of diagnostic accuracy, including the area under the receiver operating characteristic curve (AROC), sensitivities at fixed specifities, and likelihood ratios. Statistical models were used to evaluate the influence of glaucoma severity and optic disc size on the diagnostic performance of the different instruments. One eye of each individual was randomly selected for statistical analysis. From an initial group of 258 eligible subjects, 33 (13%) had images of unacceptable quality, leaving 133 glaucoma patients and 92 healthy subjects for further analysis. In the comparison of the parameters with highest values of AROC from each instrument, the GDx VCC Nerve Fiber Indicator (AROC = 0.91) and the Stratus OCT Average Thickness (AROC = 0.90) perfomed significanlty better than the HRT II Bathija discriminant function (AROC = 0.84). For all instruments, the diagnostic accuracy increased with increasing severity of visual field defects. For the GDx VCC and Stratus OCT parameters, an increase in the size of the optic disc was related to a decrease in the sensitivity for glaucoma detection. An opposite effect was observed with the HRT II: a decrease in the size of the optic disc was related to a decrease in the sensitivity for glaucoma diagnosis. Abnormal results for each of the instruments were associated with strong positive likelihood ratios, indicating a large change from prestest to posttest probability of glaucoma. These results suggest that the finding of an abnormal result in any of these tests, when assessing a patient suspect of having glaucoma, would substantially raise the probability of disease. Results of the evaluation of patients with preperimetric glaucoma also suggest that all three instruments are able to detect early glaucomatous structural damage in the absence of visual field loss
9

Potencial evocado visual multifocal em olhos com hemianopsia temporal por compressão quiasmática. Correlação com a perimetria computadorizada e a tomografia de coerência óptica / Multifocal visual evoked potential in eyes with temporal hemianopia from chiasmal compression. Correlation with standard automated perimetry and OCT findings

Rafael Miranda Sousa 05 May 2017 (has links)
OBJETIVO: Avaliar a capacidade do potencial visual evocado multifocal (PEV-mf) em diferenciar pacientes portadores de hemianopsia temporal de controles normais e avaliar a correlação entre o PEV-mf, o campo visual (CV) realizado com a perimetria automatizada e a tomografia de coerência óptica de domínio fourier (TCO-dF). MÉTODOS: Vinte sete olhos de 21 pacientes com defeito de campo visual temporal secundário a compressão quiasmática e 43 olhos de 23 controles normais foram submetidos aos exames PEV-mf, CV e TCO-dF (3D OCT-1000®, Topcon) da mácula e da camada de fibras nervosas da retina (CFNR). Foi calculada a média das respostas do PEV-mf global, do PEV-mf central e a média de espessura do TCO-dF da mácula para cada quadrante e para cada hemicampo, enquanto a espessura da CFNR foi dividida em 12 setores ao redor do nervo óptico. A perda de CV foi calculada para os quatro quadrantes e para os hemicampos temporal e nasal no CV 24-2 e CV 10-2. Os dois grupos foram comparados utilizando equações de estimativas generalizadas (GEE) e as correlações entre o PEV-mf, CV e o TCO-dF foram calculadas. RESULTADOS: As médias das amplitude P1 e N2 do PEV-mf global e central para os hemicampos e os quadrantes temporais foram significativamente menores nos pacientes que nos controles (p < 0.004). Não houve diferença estatística entre os grupos para os parâmetros de amplitudes do PEV-mf nos setores nasais. Não houve diferença estatística nas médias das latências do PEV-mf global e central entre os pacientes e os controles normais. Foi encontrada correlação moderada, estatisticamente significativa, entre os parâmetros de amplitudes temporais do PEV-mf - global e central com a perda de CV 24-2 e 10-2 temporal, assim como com as medidas de espessura macular e da espessura CFNR na TCO-dF. CONCLUSÕES: As médias das amplitudes do PEV-mf foram capazes de diferenciar olhos de pacientes com hemianopsia dos controles normais e apresentaram correlação significativa com os dados obtidos pela perimetria automatizada e pelo TCO-dF. Estes dados sugerem que o PEV-mf global e central podem ser utilizados na detecção de anormalidades do campo visual em pacientes portadores de compressão quiasmática / PURPOSE: To evaluate the ability of multifocal visual evoked potential (mfVEP) to differentiate patients with temporal hemianopia due to chiasmal compression from normal controls. To assess the relationship between mfVEP, standard automated perimetry (SAP) and fourier domain-optical coherence tomography (fd-OCT). METHODS: Twenty-seven eyes of 21 patients with permanent temporal visual field (VF) defects from chiasmal compression and 43 eyes of 23 healthy controls underwent mfVEP, SAP and fd-OCT (3D OCT-1000®, Topcon) macular and peripapillary retinal nerve fiber layer (RNFL) measurements. It was averaged the responses for global mfVEP, central mfVEP and fd-OCT macular measurements were averaged in quadrants and halves, while peripapillary RNFL thickness was averaged in 12 sectors around the disc. VF loss was estimated in four quadrants and each half of 24-2 and 10-2 strategy test points. The two groups were compared using generalized estimated equations (GEE). Correlations between mfVEP, VF and fd-OCT findings were verified. RESULTS: Global and central mfVEP P1 and N2 amplitude parameters of temporal measurements were significantly smaller in patients than controls (p < 0.004). No significant differences were observed between the groups with respect to mfVEP amplitude parameters from the nasal measurements. No significant differences were observed in global and central mfVEP latency parameters for all averaged measurements between patients and healthy controls. A significant moderate correlation was found between global and central mfVEP amplitude parameters of temporal measurements and temporal VF 24-2 and 10-2 loss as well as with corresponding fd-OCT macular and RNFL thickness measurements. CONCLUSIONS: mfVEP amplitude parameters were able to differentiate eyes with temporal hemianopia from controls and were significant correlated with VF and fd-OCT findings. These data suggest that it is a useful technology for detecting visual abnormalities in patients with chiasmal compression
10

Comparação entre diversas técnicas de imagem para diagnóstico do glaucoma / Comparison of different imaging techniques to diagnose glaucoma

Roberto Murad Vessani 20 March 2008 (has links)
O objetivo desse estudo foi comparar a habilidade da avaliação subjetiva do disco óptico e da camada de fibras nervosas (CFN) por oftalmologistas generalistas e por um glaucomatólogo com medidas objetivas pela tomografia de coerência óptica (Stratus OCT), oftalmoscopia confocal de varredura a laser (HRTIII), e a polarimetria de varredura a laser (GDxECC) para discriminar olhos glaucomatosos de olhos normais. 61 olhos glaucomatosos e 57 olhos normais de 118 indivíduos foram incluídos nesse estudo. Três oftalmologistas generalistas independentes e um glaucomatólogo avaliaram fotografias estereoscópicas do disco óptico. Curvas ROC (Receiver Operator Characteristic) foram construídas para cada técnica de imagem e a sensibilidade a uma especificidade fixa foi determinada. Comparações das áreas sob essas curvas (AROC) e a concordância (k) foram determinadas entre a graduação das fotografias estereoscópicas e o melhor parâmetro de cada exame de imagem computadorizado. O melhor parâmetro de cada técnica de imagem computadorizada (CFN temporal inferior do Stratus OCT = 0,92; área integrada vertical da topografia do disco óptico pelo Stratus OCT = 0,86; espessura macular do setor inferior externo fornecido pelo Stratus OCT = 0,82; NFI do GDxECC = 0,91; razão área E/D do HRT3 = 0,83) mostrou AROC maior do que a graduação das fotografias estereoscópicas por oftalmologistas generalistas (0,80) para separar olhos glaucomatosos de olhos normais. A graduação por glaucomatólogo forneceu AROC igual ou maior (0,92) do que o melhor parâmetro de exame computadorizado de imagem. A avaliação das fotografias estereoscópicas por glaucomatólogo mostrou melhor concordância com o melhor parâmetro de cada técnica de imagem quantitativa na classificação de olhos como glaucomatosos ou normais comparadas à avaliação de fotografias estereoscópicas por oftalmologistas generalistas. A combinação da avaliação subjetiva do disco óptico por oftalmologistas generalistas com parâmetros objetivos da CFN melhorou a identificação de olhos com glaucoma em uma proporção maior do que a combinação desses parâmetros objetivos com a avaliação do disco óptico por um glaucomatólogo (29,5% versus 19,7%, respectivamente). Os resultados sugerem que a habilidade diagnóstica de todos os exames de imagem computadorizados estudados mostrou melhor desempenho que a avaliação subjetiva do disco óptico por oftalmologistas generalistas, mas não por um glaucomatólogo. Medidas objetivas da CFN podem permitir um aperfeiçoamento na detecção de glaucoma quando combinados com a avaliação subjetiva do disco óptico por oftalmologistas generalistas ou por um glaucomatólogo. / The purpose of this study was to compare the ability of subjective assessment of optic nerve head and retinal nerve fiber layer by general ophthalmologists and by a glaucoma expert with objective measurements by optical coherence tomography (Stratus OCT, Carl Zeiss Meditec, Inc.), confocal scanning laser ophthalmoscope (HRT III; Heidelberg Engineering, Heidelberg, Germany), and scanning laser polarimetry (GDx ECC; Carl Zeiss Meditec, Inc., Dublin, CA) in discriminating glaucomatous and normal eyes. 61 glaucomatous and 57 normal eyes of 118 subjects were included in the study. Three independent general ophthalmologists and one glaucoma expert evaluated ONH stereophotographs. Receiver operating characteristic curves were constructed for each imaging technique and sensitivity at fixed specificity was estimated. Comparisons of areas under these curves (aROC) and agreement (k) were determined between stereophoto grading and best parameter from each technique. Best parameter from each technique showed larger aROC (StratusOCT RNFL = 0.92; StratusOCT ONH vertical integrated area = 0.86; StratusOCT macular thickness = 0.82; GDxECC = 0.91; HRT3 global cup-to-disc area ratio = 0.83) compared to stereophotograph grading by general ophthalmologists (0.80) in separating glaucomatous and normal eyes. Glaucoma expert stereophoto grading provided equal or larger aROC (0.92) than best parameter of each computerized imaging device. Stereophoto evaluated by a glaucoma expert showed better agreement with best parameter of each quantitative imaging technique in classifying eyes either as glaucomatous or normal compared to stereophoto grading by general ophthalmologists. The combination of subjective assessment of the optic disc by general ophthalmologists with RNFL objective parameters improved identification of glaucoma patients in a larger proportion than the combination of these objective parameters with subjective assessment of the optic disc by a glaucoma expert (29.5% versus 19.7%, respectively). The results suggests that the diagnostic ability of all imaging techniques showed better performance than subjective assessment of the ONH by general ophthalmologists, but not by a glaucoma expert. Objective RNFL measurements may provide improvement in glaucoma detection when combined with subjective assessment of the optic disc by general ophthalmologists or by a glaucoma expert.

Page generated in 0.2852 seconds