• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 11
  • Tagged with
  • 11
  • 11
  • 11
  • 6
  • 5
  • 5
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Estudo comparativo de potenciais evocados visuais entre diferentes equipamentos Nihon Kohden

Pereira, Vanessa Caldeira January 2017 (has links)
Orientador: Luiz Antônio de Lima Resende / Resumo: Potenciais evocados visuais (PEV) avaliam vias visuais para fins clínicos. Os objetivos deste estudo foram comparar morfologias e latências de ondas P100, obtidas com diferentes bandas passantes de filtros, em 2 equipamentos distintos de um mesmo fabricante (5 – 20 Hz, e 5 – 100 Hz, Grupo I) e, após escolha da melhor banda passante de filtros, comparar valores de latências de ondas P100 obtidas em 2 equipamentos distintos de um mesmo fabricante, em voluntários normais (Grupo II) e em pacientes com queixas de alterações visuais (Grupo III). Todos os procedimentos foram realizados em equipamentos Nihon-Kohden, modelos Neuropack 2 e MEB 9400. No Grupo I, nos 2 equipamentos, filtros de 5 – 20 Hz proporcionaram registros gráficos melhores e mais nítidos, porém com latências mais prolongadas, em relação aos filtros de 5 a 100 Hz (média de 8 milissegundos, p < 0,0001). Em 20 voluntários do Grupo II e 30 pacientes do grupo III, todos avaliados com filtros de 5 a 20 Hz, observaram-se latências mais prolongadas, em média 6 a 8 milisegundos, utilizando-se equipamento MEB 9400 (p < 0,0001). Em conclusão, filtros de 5 a 20 Hz possibilitaram registros de melhor qualidade das ondas P100, com latências mais prolongadas, se comparados aos filtros de 5-100 Hz. Além disso, utilizando-se a mesma banda passante de filtros, e todas as outras condições técnicas idênticas, diferentes equipamentos, de um mesmo fabricante, fornecem valores distintos de latências das ondas P100, para voluntários norm... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Visual evoked potentials (VEP) evaluate visual pathways for clinical purposes. The objective of this study were to compare P100 wave latencies and morphologies obtained with different band-pass filter in 2 different equipments from the same manufacturer (5 - 20 Hz, and 5 - 100 Hz, Group I). After choosing the best band-pass filter for the record of the P100 waves, latencies were compaired between 2 equipments of the same manufacture. All procedures were obtained from Nihon-Kohden equipments, Neuropack 2 and MEB 9400 models. For the Group I, in the 2 equipments, 5 - 20 Hz band-pass filter furnished better and clearer graphic records, but with longer latencies, in relation to the 5 - 100 Hz band-pass filter (mean of 8 milliseconds, p <0.0001). For the 20 volunteers (Group II) and 30 patients (Group III), all evaluated with 5 – 20 Hz band-pass filter, longer latencies were observed, on average 6 to 8 milliseconds, using MEB 9400 equipment (p <0, 0001). In conclusion, 5 to 20 Hz band-pass filter allowed better quality records of the P100 waves, with longer latencies, if compared to the 5-100 Hz band-pass filter. In addition, using the same filter band-pass, and all of the other technical parameters identical, different equipments from the same manufacturer provide different P100 latency values for normal volunteers or patients (p <0.0001). / Mestre
2

Estudo comparativo de potenciais evocados visuais entre diferentes equipamentos Nihon Kohden / Comparative study of visual evoked potentials between diferent Nihon Kohden equipments

Pereira, Vanessa Caldeira [UNESP] 03 May 2017 (has links)
Submitted by VANESSA CALDEIRA PEREIRA null (van_caldeira@hotmail.com) on 2017-06-13T15:16:21Z No. of bitstreams: 1 V-TESE-FINAL-06-04-2017.doc: 2223616 bytes, checksum: a35d07356012535ce841f6cc9d384e4c (MD5) / Rejected by Luiz Galeffi (luizgaleffi@gmail.com), reason: Solicitamos que realize uma nova submissão seguindo as orientações abaixo: A versão final da dissertação/tese deve ser submetida no formato PDF (Portable Document Format). O arquivo PDF não deve estar protegido e a dissertação/tese deve estar em um único arquivo, inclusive os apêndices e anexos, se houver. Sua tese/dissertação deve estar de acordo com as normas de sua unidade/programa de pós-graduação, encontradas no link abaixo: http://www.fmb.unesp.br/Home/Pos-Graduacao/mestradoacademicoedoutorado/pgbasesgeraisdacirurgia/bases-gerais-da-cirurgia-01-07-2015-pg-pdf.pdf Por favor, corrija o formato do arquivo e realize uma nova submissão. Agradecemos a compreensão. on 2017-06-13T17:40:33Z (GMT) / Submitted by VANESSA CALDEIRA PEREIRA null (van_caldeira@hotmail.com) on 2017-06-15T20:49:33Z No. of bitstreams: 1 V-TESE-FINAL-06-04-2017.pdf: 1457681 bytes, checksum: fe7cccf59a202c11ede49f405cf80220 (MD5) / Rejected by Luiz Galeffi (luizgaleffi@gmail.com), reason: Solicitamos que realize uma nova submissão seguindo as orientações abaixo: Seu arquivo deve estar de acordo com a Instrução Normativa nº 001/2015, de 29 de abril de 2015, do Conselho do Programa de Pós-graduação em Bases Gerais da Cirurgia, encontrada na página 12 do documento no link abaixo: http://www.fmb.unesp.br/Home/Pos-Graduacao/mestradoacademicoedoutorado/pgbasesgeraisdacirurgia/bases-gerais-da-cirurgia-01-07-2015-pg-pdf.pdf Para maiores dúvida sobre as normas de sua unidade, entre em contato com seu programa de pós-graduação. Atenciosamente. on 2017-06-19T13:15:06Z (GMT) / Submitted by VANESSA CALDEIRA PEREIRA null (van_caldeira@hotmail.com) on 2017-06-30T13:35:21Z No. of bitstreams: 1 Dissertação para arquivamento.pdf: 1265018 bytes, checksum: 1364017705c245744d580c2a1f304d28 (MD5) / Approved for entry into archive by Luiz Galeffi (luizgaleffi@gmail.com) on 2017-06-30T14:32:35Z (GMT) No. of bitstreams: 1 pereira_vc_me_bot.pdf: 1265018 bytes, checksum: 1364017705c245744d580c2a1f304d28 (MD5) / Made available in DSpace on 2017-06-30T14:32:35Z (GMT). No. of bitstreams: 1 pereira_vc_me_bot.pdf: 1265018 bytes, checksum: 1364017705c245744d580c2a1f304d28 (MD5) Previous issue date: 2017-05-03 / Potenciais evocados visuais (PEV) avaliam vias visuais para fins clínicos. Os objetivos deste estudo foram comparar morfologias e latências de ondas P100, obtidas com diferentes bandas passantes de filtros, em 2 equipamentos distintos de um mesmo fabricante (5 – 20 Hz, e 5 – 100 Hz, Grupo I) e, após escolha da melhor banda passante de filtros, comparar valores de latências de ondas P100 obtidas em 2 equipamentos distintos de um mesmo fabricante, em voluntários normais (Grupo II) e em pacientes com queixas de alterações visuais (Grupo III). Todos os procedimentos foram realizados em equipamentos Nihon-Kohden, modelos Neuropack 2 e MEB 9400. No Grupo I, nos 2 equipamentos, filtros de 5 – 20 Hz proporcionaram registros gráficos melhores e mais nítidos, porém com latências mais prolongadas, em relação aos filtros de 5 a 100 Hz (média de 8 milissegundos, p < 0,0001). Em 20 voluntários do Grupo II e 30 pacientes do grupo III, todos avaliados com filtros de 5 a 20 Hz, observaram-se latências mais prolongadas, em média 6 a 8 milisegundos, utilizando-se equipamento MEB 9400 (p < 0,0001). Em conclusão, filtros de 5 a 20 Hz possibilitaram registros de melhor qualidade das ondas P100, com latências mais prolongadas, se comparados aos filtros de 5-100 Hz. Além disso, utilizando-se a mesma banda passante de filtros, e todas as outras condições técnicas idênticas, diferentes equipamentos, de um mesmo fabricante, fornecem valores distintos de latências das ondas P100, para voluntários normais ou pacientes (p < 0,0001). / Visual evoked potentials (VEP) evaluate visual pathways for clinical purposes. The objective of this study were to compare P100 wave latencies and morphologies obtained with different band-pass filter in 2 different equipments from the same manufacturer (5 - 20 Hz, and 5 - 100 Hz, Group I). After choosing the best band-pass filter for the record of the P100 waves, latencies were compaired between 2 equipments of the same manufacture. All procedures were obtained from Nihon-Kohden equipments, Neuropack 2 and MEB 9400 models. For the Group I, in the 2 equipments, 5 - 20 Hz band-pass filter furnished better and clearer graphic records, but with longer latencies, in relation to the 5 - 100 Hz band-pass filter (mean of 8 milliseconds, p <0.0001). For the 20 volunteers (Group II) and 30 patients (Group III), all evaluated with 5 – 20 Hz band-pass filter, longer latencies were observed, on average 6 to 8 milliseconds, using MEB 9400 equipment (p <0, 0001). In conclusion, 5 to 20 Hz band-pass filter allowed better quality records of the P100 waves, with longer latencies, if compared to the 5-100 Hz band-pass filter. In addition, using the same filter band-pass, and all of the other technical parameters identical, different equipments from the same manufacturer provide different P100 latency values for normal volunteers or patients (p <0.0001).
3

Desenvolvimento de um dispositivo SSVEP rápido e confiável utilizando eletrodos a seco e frequências acima de 25 Hz / Development of a fast and reliable SSVEP device using dry electrodes and frequencies above 25 Hz

Silva, Andrei Damian da 02 March 2018 (has links)
Submitted by JÚLIO HEBER SILVA (julioheber@yahoo.com.br) on 2018-03-13T17:24:13Z No. of bitstreams: 2 Dissertação - Andrei Damian da Silva - 2018.pdf: 2168750 bytes, checksum: 4d47d811f294faae439470b427c48f3e (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2018-03-14T10:57:00Z (GMT) No. of bitstreams: 2 Dissertação - Andrei Damian da Silva - 2018.pdf: 2168750 bytes, checksum: 4d47d811f294faae439470b427c48f3e (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2018-03-14T10:57:00Z (GMT). No. of bitstreams: 2 Dissertação - Andrei Damian da Silva - 2018.pdf: 2168750 bytes, checksum: 4d47d811f294faae439470b427c48f3e (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2018-03-02 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / This paper presents a new approach for the processing and classification of visual evoked potentials of steady state (SSVEP). It introduces a ensemble tree model that combines canonical correlation analysis data with methods based on estimation of power spectral density. The stimuli were created using LEDs, from 7.04 Hz to 38.46 Hz. Data were collected using the Texas Instruments ADS1299EEG-Fe and three electrodes. The tests were performed for different distances and light intensities to evaluate the performance of the algorithm under different conditions. In all, 22 participants were recruited, and the average classification was 99.1 ± 2.27% with fixed decision time of 1 second. / Este trabalho apresenta uma nova abordagem para o processamento e classificação de potenciais evocados visuais de estado estacionário (SSVEP). Este trabalho introduz um modelo de em aprendizagem por agrupamento de árvores de decisão que combina dados de análise da correlação canônica com métodos baseados na estimativa da densidade espectral de potência. Os estímulos foram criados utilizando LEDs, com frequência de 7.04 Hz até 38.46 Hz. Os dados foram coletados utilizando a placa ADS1299EEG-Fe da Texas Instruments e três eletrodos. Os testes foram realizados para diferentes distâncias e intensidades luminosas com o objetivo de avaliar o desempenho do algoritmo em condições diversas. Ao todo, 22 participantes foram recrutados e a taxa de acertos média foi de 99.1±2.27% com tempo de decisão fixo em 1 segundo.
4

Estudo do potencial evocado auditivo de tronco cerebral e do potencial evocado visual em crianças e adolescentes candidatos a transplante hepático

Nora, Daniel Bocchese January 1999 (has links)
Introdução: Os potenciais evocados auditivos e visuais são propostos como exames úteis no diagnóstico da encefalopatia hepática subclínica. Entretanto não existem estudos demonstrando a sua utilidade na população de pacientes pediátricos. Este estudo foi realizado na tentativa de avaliar diferentes tipos de potenciais na detecção da encefalopatia hepática subclínica na população pediátrica candidata a transplante hepático. Métodos: Realizou-se um estudo de caso controle onde potenciais evocados auditivos e visuais foram realizados em 15 pacientes pediátricos candidatos a transplante hepático que não apresentavam sinais clínicos de encefalopatia hepática. As latências de onda obtidas, nesses exames, foram comparadas com 16 controles saudáveis com faixas etárias similares. Exames laboratoriais de função hepática e eletroencefalograma foram, também, realizados para examinar as suas correlações com os resultados dos potenciais evocados. Resultados: Não foram encontradas diferenças, estatisticamente significativas entre os pacientes e os controles nos potenciais evocados auditivos, porém no potencial evocado visual, os pacientes candidatos a transplante hepático demonstraram latências N1 (N75) significativamente prolongadas quando comparadas com os controles. Não houve atraso significativo nas outras ondas. Por outro lado, latências prolongadas no potencial evocado auditivo tiveram uma correlação positiva com anormalidades no eletroencefalograma, apenas entre crianças com patologia hepática. Tal correlação não foi observada no potencial evocado visual. Conclusões: Os potenciais evocados podem ser usados na detecção de alterações relacionadas à encefalopatia hepática nos pacientes pediátricos, todavia outros estudos são necessários para determinar as suas especificidades e sensibilidades.
5

Estudo do potencial evocado auditivo de tronco cerebral e do potencial evocado visual em crianças e adolescentes candidatos a transplante hepático

Nora, Daniel Bocchese January 1999 (has links)
Introdução: Os potenciais evocados auditivos e visuais são propostos como exames úteis no diagnóstico da encefalopatia hepática subclínica. Entretanto não existem estudos demonstrando a sua utilidade na população de pacientes pediátricos. Este estudo foi realizado na tentativa de avaliar diferentes tipos de potenciais na detecção da encefalopatia hepática subclínica na população pediátrica candidata a transplante hepático. Métodos: Realizou-se um estudo de caso controle onde potenciais evocados auditivos e visuais foram realizados em 15 pacientes pediátricos candidatos a transplante hepático que não apresentavam sinais clínicos de encefalopatia hepática. As latências de onda obtidas, nesses exames, foram comparadas com 16 controles saudáveis com faixas etárias similares. Exames laboratoriais de função hepática e eletroencefalograma foram, também, realizados para examinar as suas correlações com os resultados dos potenciais evocados. Resultados: Não foram encontradas diferenças, estatisticamente significativas entre os pacientes e os controles nos potenciais evocados auditivos, porém no potencial evocado visual, os pacientes candidatos a transplante hepático demonstraram latências N1 (N75) significativamente prolongadas quando comparadas com os controles. Não houve atraso significativo nas outras ondas. Por outro lado, latências prolongadas no potencial evocado auditivo tiveram uma correlação positiva com anormalidades no eletroencefalograma, apenas entre crianças com patologia hepática. Tal correlação não foi observada no potencial evocado visual. Conclusões: Os potenciais evocados podem ser usados na detecção de alterações relacionadas à encefalopatia hepática nos pacientes pediátricos, todavia outros estudos são necessários para determinar as suas especificidades e sensibilidades.
6

Estudo do potencial evocado auditivo de tronco cerebral e do potencial evocado visual em crianças e adolescentes candidatos a transplante hepático

Nora, Daniel Bocchese January 1999 (has links)
Introdução: Os potenciais evocados auditivos e visuais são propostos como exames úteis no diagnóstico da encefalopatia hepática subclínica. Entretanto não existem estudos demonstrando a sua utilidade na população de pacientes pediátricos. Este estudo foi realizado na tentativa de avaliar diferentes tipos de potenciais na detecção da encefalopatia hepática subclínica na população pediátrica candidata a transplante hepático. Métodos: Realizou-se um estudo de caso controle onde potenciais evocados auditivos e visuais foram realizados em 15 pacientes pediátricos candidatos a transplante hepático que não apresentavam sinais clínicos de encefalopatia hepática. As latências de onda obtidas, nesses exames, foram comparadas com 16 controles saudáveis com faixas etárias similares. Exames laboratoriais de função hepática e eletroencefalograma foram, também, realizados para examinar as suas correlações com os resultados dos potenciais evocados. Resultados: Não foram encontradas diferenças, estatisticamente significativas entre os pacientes e os controles nos potenciais evocados auditivos, porém no potencial evocado visual, os pacientes candidatos a transplante hepático demonstraram latências N1 (N75) significativamente prolongadas quando comparadas com os controles. Não houve atraso significativo nas outras ondas. Por outro lado, latências prolongadas no potencial evocado auditivo tiveram uma correlação positiva com anormalidades no eletroencefalograma, apenas entre crianças com patologia hepática. Tal correlação não foi observada no potencial evocado visual. Conclusões: Os potenciais evocados podem ser usados na detecção de alterações relacionadas à encefalopatia hepática nos pacientes pediátricos, todavia outros estudos são necessários para determinar as suas especificidades e sensibilidades.
7

Comparação entre o PERG e o PEVP de crianças com ambliopia estrábica e anisometrópica

Lima, Luiz Cláudio Santos de Souza January 2017 (has links)
Submitted by Ana Lúcia Torres (bfmhuap@gmail.com) on 2017-09-19T15:20:57Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) COMPARAÇÃO ENTRE O PEVP E O PERG DE CRIANÇAS COM AMBLIOPIA ESTRÁBICA E ANISOMETROPICA 1_3 V5.pdf: 3334834 bytes, checksum: f21a6dfb6b0e7fbc0eb2ef6452f3f4c0 (MD5) / Approved for entry into archive by Ana Lúcia Torres (bfmhuap@gmail.com) on 2017-09-19T15:21:17Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) COMPARAÇÃO ENTRE O PEVP E O PERG DE CRIANÇAS COM AMBLIOPIA ESTRÁBICA E ANISOMETROPICA 1_3 V5.pdf: 3334834 bytes, checksum: f21a6dfb6b0e7fbc0eb2ef6452f3f4c0 (MD5) / Made available in DSpace on 2017-09-19T15:21:17Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) COMPARAÇÃO ENTRE O PEVP E O PERG DE CRIANÇAS COM AMBLIOPIA ESTRÁBICA E ANISOMETROPICA 1_3 V5.pdf: 3334834 bytes, checksum: f21a6dfb6b0e7fbc0eb2ef6452f3f4c0 (MD5) Previous issue date: 2017 / Universidade Federal Fluminense. Centro de Ciência Médicas / A ambliopia é uma desordem neurológica do desenvolvimento visual que se manifesta com a redução de capacidades sensoriais em ambos os olhos ou mais comumente de forma monocular, diante da total correção óptica e na ausência de anormalidades do exame clínico. Está associada ao estrabismo e a anisometropia e menos frequentemente à privação visual. As ambliopias estrábica e anisometrópicas apresentam diferenças nas suas fisiopatologias. Comparamos as respostas eletrofisiológicas das ambliopias estrábica e anisometrópicas com o eletroretinograma padrão (PERG) e o potencial evocado visual padrão (PVEP). Cinquenta e seis pacientes, 18 crianças amblíopes anisometrópicas hipermetrópicas (idade média e desviopadrão 9,7 ± 2,5); 19 crianças com ambliopia estrábica esotrópica (idade média e desvio padrão 10,3 ± 2,6) e 19 crianças emétropes normais (idade média e desvio-padrão 10,1 ± 2,2) foram divididos em três grupos. Após o exame oftalmológico de rotina, o eletroretinograma padrão (PERG) e o potencial evocação visual padrão (PVEP) foram registrados em respostas a um estímulo de padrão reverso à taxa de duas reversões/segundo. A diferença entre ambliopia anisometrópica hipermetrópica e ambliopia estrábica em relação às latências das ondas P100 / P50 / N95 (p = 0,055 / 0,855 / 0,132) e as amplitudes P100 / P50 / N95 (p = 0,980 / 0,095 / 0,045) não foi estatisticamente significante. No entanto, houve uma diferença estatística significante entre a ambliopia estrábica e os controles com relação às latências das ondas P100 / P50 / N95 (p = 0,000 / 0,006 / 0,004). Nossos achados indicam que, apesar das diferenças clínicas e fisiopatológicas entre pacientes amblíopes estrábicos esotrópicos e os pacientes com ambliopia anisometrópica hipermetrópica, não foram encontradas diferenças nas respostas de PVEP e PERG. Os componentes anormais do PVEP e PERG em crianças amblíopes podem refletir uma disfunção da retina e da via visual. / Amblyopia is a neurological disorder of visual development manifested by the reduction of sensory abilities in both eyes or more commonly monocular in the face of total optical correction and absence of clinical examination abnormalities. It is associated with strabismus and anisometropia, and less often with visual deprivation. Strabismus amblyopia and anisometropic amblyopia present clinical differences and their pathophysiology. We compared the electrophysiological responses of the strabismic and anisometropic amblyopia with the pattern electroretinogram (PERG) and the pattern visual evoked potential (PVEP). Fifty-six patients, 18 hypermetropic anisometropic amblyopic children (mean age and standard deviation 9.7 ± 2.5); 19 children with esotropic strabismus amblyopia (mean age and standard deviation 10.3 ± 2.6) and 19 normal emetopic children (mean age and standard deviation 10.1 ± 2.2) were divided into three groups. After routine ophthalmologic examination, the pattern electroretinogram (PERG) and standard visual evoked potential (PVEP) were recorded in responses to a reverse pattern stimulus at the rate of two reversions/second. The difference between hypermetropic anisometropic amblyopia and strabismus esotropic amblyopia in relation to P100 / P50 / N95 wave latencies (p = 0.055 / 0.855 / 0.132) and P100 / P50 / N95 amplitudes (p = 0.980 / 0.095 / 0.045) was not statistically significant. However, there was a statistically significant difference between strabismic amblyopia and controls with respect to P100 / P50 / N95 wave latencies (p = 0.000 / 0.006 / 0.004). Our findings indicate that, despite clinical and pathophysiological differences between esotropic strabismus-amblyopic patients and patients with hypermetropic anisometropic amblyopia, no differences in PVEP and PERG responses were found. Abnormal PVEP and PERG components in amblyopic children may reflect retinal and visual pathway dysfunction.
8

Potencial evocado visual multifocal em olhos com hemianopsia temporal por compressão quiasmática. Correlação com a perimetria computadorizada e a tomografia de coerência óptica / Multifocal visual evoked potential in eyes with temporal hemianopia from chiasmal compression. Correlation with standard automated perimetry and OCT findings

Sousa, Rafael Miranda 05 May 2017 (has links)
OBJETIVO: Avaliar a capacidade do potencial visual evocado multifocal (PEV-mf) em diferenciar pacientes portadores de hemianopsia temporal de controles normais e avaliar a correlação entre o PEV-mf, o campo visual (CV) realizado com a perimetria automatizada e a tomografia de coerência óptica de domínio fourier (TCO-dF). MÉTODOS: Vinte sete olhos de 21 pacientes com defeito de campo visual temporal secundário a compressão quiasmática e 43 olhos de 23 controles normais foram submetidos aos exames PEV-mf, CV e TCO-dF (3D OCT-1000®, Topcon) da mácula e da camada de fibras nervosas da retina (CFNR). Foi calculada a média das respostas do PEV-mf global, do PEV-mf central e a média de espessura do TCO-dF da mácula para cada quadrante e para cada hemicampo, enquanto a espessura da CFNR foi dividida em 12 setores ao redor do nervo óptico. A perda de CV foi calculada para os quatro quadrantes e para os hemicampos temporal e nasal no CV 24-2 e CV 10-2. Os dois grupos foram comparados utilizando equações de estimativas generalizadas (GEE) e as correlações entre o PEV-mf, CV e o TCO-dF foram calculadas. RESULTADOS: As médias das amplitude P1 e N2 do PEV-mf global e central para os hemicampos e os quadrantes temporais foram significativamente menores nos pacientes que nos controles (p < 0.004). Não houve diferença estatística entre os grupos para os parâmetros de amplitudes do PEV-mf nos setores nasais. Não houve diferença estatística nas médias das latências do PEV-mf global e central entre os pacientes e os controles normais. Foi encontrada correlação moderada, estatisticamente significativa, entre os parâmetros de amplitudes temporais do PEV-mf - global e central com a perda de CV 24-2 e 10-2 temporal, assim como com as medidas de espessura macular e da espessura CFNR na TCO-dF. CONCLUSÕES: As médias das amplitudes do PEV-mf foram capazes de diferenciar olhos de pacientes com hemianopsia dos controles normais e apresentaram correlação significativa com os dados obtidos pela perimetria automatizada e pelo TCO-dF. Estes dados sugerem que o PEV-mf global e central podem ser utilizados na detecção de anormalidades do campo visual em pacientes portadores de compressão quiasmática / PURPOSE: To evaluate the ability of multifocal visual evoked potential (mfVEP) to differentiate patients with temporal hemianopia due to chiasmal compression from normal controls. To assess the relationship between mfVEP, standard automated perimetry (SAP) and fourier domain-optical coherence tomography (fd-OCT). METHODS: Twenty-seven eyes of 21 patients with permanent temporal visual field (VF) defects from chiasmal compression and 43 eyes of 23 healthy controls underwent mfVEP, SAP and fd-OCT (3D OCT-1000®, Topcon) macular and peripapillary retinal nerve fiber layer (RNFL) measurements. It was averaged the responses for global mfVEP, central mfVEP and fd-OCT macular measurements were averaged in quadrants and halves, while peripapillary RNFL thickness was averaged in 12 sectors around the disc. VF loss was estimated in four quadrants and each half of 24-2 and 10-2 strategy test points. The two groups were compared using generalized estimated equations (GEE). Correlations between mfVEP, VF and fd-OCT findings were verified. RESULTS: Global and central mfVEP P1 and N2 amplitude parameters of temporal measurements were significantly smaller in patients than controls (p < 0.004). No significant differences were observed between the groups with respect to mfVEP amplitude parameters from the nasal measurements. No significant differences were observed in global and central mfVEP latency parameters for all averaged measurements between patients and healthy controls. A significant moderate correlation was found between global and central mfVEP amplitude parameters of temporal measurements and temporal VF 24-2 and 10-2 loss as well as with corresponding fd-OCT macular and RNFL thickness measurements. CONCLUSIONS: mfVEP amplitude parameters were able to differentiate eyes with temporal hemianopia from controls and were significant correlated with VF and fd-OCT findings. These data suggest that it is a useful technology for detecting visual abnormalities in patients with chiasmal compression
9

Desenvolvimento da acuidade visual de resolução de grades em prematuros durante o primeiro ano de vida : estudo eletrofisiológico pelo registro dos potenciais visuais evocados de varredura / Grating visual acuity development in preterm infants during the first year of life: an electrophysiological study using sweep visual evoked potentials

Haro, Filomena Maria Buosi de 18 August 2003 (has links)
Objetivos: determinar a acuidade visual de resolução de grades (AV) durante o primeiro ano de vida por meio dos registros dos potenciais visuais evocados de varredura em grupos de crianças nascidas prematuramente (RNPT) e a termo (RNT); comparar os valores finais da AV no grupo RNPT em relação à idade gestacional e ao desenvolvimento neuropsicomotor e comparar as curvas de desenvolvimento visual entre os grupos RNPT e RNT. Casuística e métodos: Estudo realizado em 25 RNT e 36 RNPT acompanhados em ambulatório e submetidos a avaliações oftalmológica e neuropediátrica. O grupo RNPT foi dividido em subgrupos com relação a idade gestacional e desenvolvimento neuropsicomotor. Para a medida da AV foi utilizado o aplicativo NuDIVA (\"Digital Infant Visual Assessment\") calculando-se a AV em logaritmo do mínimo ângulo de resolução (logMAR) através de curva de regressão linear, relacionando-se a amplitude do potencial do segundo harmônico à freqüência espacial linear. Na análise estatística utilizou-se método de Fischer, teste t, análise de variância (ANOVA) e teste para comparação entre retas de regressão linear simples. O nível de significância foi fixado em 0,05. Resultados: Estrabismo foi detectado em cinco crianças, todas do grupo RNPT, quatro delas com alteração neurológica (p=0,07). Erros de refração com necessidade de prescrição óptica foi encontrado em seis crianças, todas do grupo RNPT (p=0,07). A medida da AV foi obtida com sucesso em 96,4% dos casos, sendo ao final do primeiro ano de vida significativamente inferior nos RNPT com alteração neurológica (p<0,05). A medida da AV estimada ao nascimento foi maior em todos os RNPT com relação aos RNT (p<0,05) porém a velocidade de aquisição da AV foi maior no grupo RNT (p<0,05). Conclusões: A AV pôde ser facilmente determinada durante o primeiro ano de vida tanto em RNPT quanto em RNT sendo seus valores semelhantes, com exceção dos RNPT que apresentaram alteração neurológica. Todos os RNPT apresentaram desenvolvimento visual semelhante, porém, significativamente inferior ao encontrado para os RNT / Purpose: Determine the grating visual acuity (VA) of a group of preterm infants using sweep visual evoked potentials (sweep-VEP). Compare the development of VA of these infants to that of normal full-term infants, with respect to: gestational age, neuropsychomotor development and visual development. Methods: The study was conducted on 25 preterm and 36 full-term infants, with follow-up ophthalmologic and neuropediatric evaluations. The preterm infants were divided into subgroups in accordance with their gestational age and neurological development. VA was assessed using the Digital Infant Visual Assessment (NuDiva) sweep-VEP system, expressed in logMAR, and threshold grating acuities were estimated using the VEP second harmonic amplitudes, determined by a linear regression line drawn through the highest spatial frequency peak and the spatial frequency at which signal amplitude reaches the noise level. Statistical analysis was performed using the Fisher, Student-t test, analysis of variance (ANOVA) and comparison by simple linear regression test between the two groups. The significance level was 0.05. Results: Strabismus was detected in five preterm infants; four of these had neurological alterations (p=0.07). Prescription for refractive errors was necessary in six preterm infants (p=0.07). Grating VA was assessable in 96.4% of the infants; preterm infants with neurological alterations had significantly lower grating VA (p<0.05) at the end of the first year. Early VA scores were higher in all of the preterm infants compared to the full term infants (p<0,05) but at the end of the first year of life the VA was improving at a higher rate in the full term group (p<0.05)
10

Desenvolvimento da acuidade visual de resolução de grades em prematuros durante o primeiro ano de vida : estudo eletrofisiológico pelo registro dos potenciais visuais evocados de varredura / Grating visual acuity development in preterm infants during the first year of life: an electrophysiological study using sweep visual evoked potentials

Filomena Maria Buosi de Haro 18 August 2003 (has links)
Objetivos: determinar a acuidade visual de resolução de grades (AV) durante o primeiro ano de vida por meio dos registros dos potenciais visuais evocados de varredura em grupos de crianças nascidas prematuramente (RNPT) e a termo (RNT); comparar os valores finais da AV no grupo RNPT em relação à idade gestacional e ao desenvolvimento neuropsicomotor e comparar as curvas de desenvolvimento visual entre os grupos RNPT e RNT. Casuística e métodos: Estudo realizado em 25 RNT e 36 RNPT acompanhados em ambulatório e submetidos a avaliações oftalmológica e neuropediátrica. O grupo RNPT foi dividido em subgrupos com relação a idade gestacional e desenvolvimento neuropsicomotor. Para a medida da AV foi utilizado o aplicativo NuDIVA (\"Digital Infant Visual Assessment\") calculando-se a AV em logaritmo do mínimo ângulo de resolução (logMAR) através de curva de regressão linear, relacionando-se a amplitude do potencial do segundo harmônico à freqüência espacial linear. Na análise estatística utilizou-se método de Fischer, teste t, análise de variância (ANOVA) e teste para comparação entre retas de regressão linear simples. O nível de significância foi fixado em 0,05. Resultados: Estrabismo foi detectado em cinco crianças, todas do grupo RNPT, quatro delas com alteração neurológica (p=0,07). Erros de refração com necessidade de prescrição óptica foi encontrado em seis crianças, todas do grupo RNPT (p=0,07). A medida da AV foi obtida com sucesso em 96,4% dos casos, sendo ao final do primeiro ano de vida significativamente inferior nos RNPT com alteração neurológica (p<0,05). A medida da AV estimada ao nascimento foi maior em todos os RNPT com relação aos RNT (p<0,05) porém a velocidade de aquisição da AV foi maior no grupo RNT (p<0,05). Conclusões: A AV pôde ser facilmente determinada durante o primeiro ano de vida tanto em RNPT quanto em RNT sendo seus valores semelhantes, com exceção dos RNPT que apresentaram alteração neurológica. Todos os RNPT apresentaram desenvolvimento visual semelhante, porém, significativamente inferior ao encontrado para os RNT / Purpose: Determine the grating visual acuity (VA) of a group of preterm infants using sweep visual evoked potentials (sweep-VEP). Compare the development of VA of these infants to that of normal full-term infants, with respect to: gestational age, neuropsychomotor development and visual development. Methods: The study was conducted on 25 preterm and 36 full-term infants, with follow-up ophthalmologic and neuropediatric evaluations. The preterm infants were divided into subgroups in accordance with their gestational age and neurological development. VA was assessed using the Digital Infant Visual Assessment (NuDiva) sweep-VEP system, expressed in logMAR, and threshold grating acuities were estimated using the VEP second harmonic amplitudes, determined by a linear regression line drawn through the highest spatial frequency peak and the spatial frequency at which signal amplitude reaches the noise level. Statistical analysis was performed using the Fisher, Student-t test, analysis of variance (ANOVA) and comparison by simple linear regression test between the two groups. The significance level was 0.05. Results: Strabismus was detected in five preterm infants; four of these had neurological alterations (p=0.07). Prescription for refractive errors was necessary in six preterm infants (p=0.07). Grating VA was assessable in 96.4% of the infants; preterm infants with neurological alterations had significantly lower grating VA (p<0.05) at the end of the first year. Early VA scores were higher in all of the preterm infants compared to the full term infants (p<0,05) but at the end of the first year of life the VA was improving at a higher rate in the full term group (p<0.05)

Page generated in 0.2258 seconds