• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Avaliação do tempo de secagem e da qualidade da imagem de radiografias submetidas a banho em alcool etilico em diferentes concentraçãoes / Evaluation of drying period and quality of image of radiographs submitted to immersion in ethyl alcohol at different concentrations

Damian, Melissa Feres 28 February 2005 (has links)
Orientador: Francisco Haiter Neto / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-04T04:03:37Z (GMT). No. of bitstreams: 1 Damian_MelissaFeres_D.pdf: 735238 bytes, checksum: 0d3e3519a1b631b044005442d3fbbf3e (MD5) Previous issue date: 2005 / Resumo: Com este estudo, teve-se a proposta de avaliar a ação do álcool etílico, nas concentrações de 46ºGL, 70ºGL e 92ºGL, como agente acelerador da secagem de radiografias dentárias, a fim de abreviar o tempo de processamento. Adicionalmente, foi verificado se esse produto poderia causar alterações na dens idade, nas propriedades sensitométricas e na qualidade destas radiografias após um curto período de arquivamento. Para tanto, foram utilizados os filmes radiográficos intra-orais de sensibilidade D (Dspeed), E (E-speed) e E/F (Insight) da Kodak, divididos em grupos de acordo com o uso e a concentração da substância alcoólica. Todos os filmes foram processados manualmente pelo método temperatura/tempo em câmara escura portátil para simular condições clínicas. As radiografias foram submetidas às analises densitométrica e clínica subjetiva, além da construção de curvas características para a obtenção do contraste e da sensibilidade, nos períodos correspondentes a um e seis meses após a realização do experimento, simulando condições de arquivo. Pôde-se observar que o uso do álcool etílico acelerou a secagem das radiografias independentemente do tipo de filme, sendo que o menor tempo foi obtido com a utilização da substância alcoólica de maior concentração. Contudo, os valores de densidade, contraste e sensibilidade foram alterados quando foi utilizado o álcool 70ºGL e o álcool 92ºGL, sendo que este último também foi capaz de alterar a qualidade visual das imagens. Tais alterações puderam ser visualizadas nos dois períodos de avaliação de estudo. Assim, concluiu -se que mesmo que o álcool etílico acelere a secagem das radiografias, sua utilização causou alterações capazes de prejudicar a qualidade da imagem, inclusive após um curto período de arquivamento / Abstract: This study evaluated the action of ethyl alcohol at concentrations of 46ºGL, 70ºGL and 92ºGL as an accelerator of drying of dental radiographs, with a view to reduce the time required for processing. Also, it was observed whether this product might cause alterations in the density, sensitometric properties and quality of these radiographs after a 6- month storage period. For that purpose, intraoral radiographic films D-speed, E-speed and E/F (Insight) of Kodak were employed, which were divided into groups according to the utilization and concentration of the alcoholic substance. All films were developed manually by the time-temperature method in a portable dark room, to simulate the clinical conditions. The radiographs were submitted to densitometric and clinical analyses, besides construction of characteristic curves for achievement of contrast and sensitivity, at periods corresponding to one and six months after accomplishment of the study, simulating conditions of storage. It was observed that the utilization of ethyl alcohol accelerated the drying of radiographs, regardless of the type of film; the shortest time was achieved with utilization of the alcoholic substance of highest concentration. However, the density, contrast and speed of radiographs were altered when concentrations of 70ºGL and 92ºGL were used; being that the latter also altered the visual quality of images. Such alterations could be observed at the two evaluations and study periods. Thus, it was concluded that, even though the ethyl alcohol may accelerate the drying of radiographs, its utilization caused alterations able to impair the quality of image, even after a short period of storage / Doutorado / Radiologia Odontologica / Doutor em Radiologia Odontológica
2

Avaliação objetiva da qualidade do filme Contrast® FV-58 em soluções frescas e degradadas

Carvalho, Fabiano Pachêco de 10 December 2009 (has links)
Made available in DSpace on 2015-05-14T12:56:05Z (GMT). No. of bitstreams: 1 arquivototal.pdf: 1129487 bytes, checksum: 9b4bcacf33a745b3f606911583f777bb (MD5) Previous issue date: 2009-12-10 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / The use of intraoral radiographs is quite common in daily practice of dentistry and the radiographic film has been the most used means of capture, disposal and storage of radiographic images. However, X-ray emission can produce deleterious biological effects. One of the easiest ways to reduce the radiation needed to produce radiographs is the use of more sensitive films. The choice of these films is essential, since the radiographic quality is not compromised. The films have different behaviors in the changing of the type of processing, concentration, temperature and state of degradation of processing solutions. This study aimed to evaluate the F-speed film DFL Contrast® FV-58 and compare it with the Kodak Insight® E/F speed film. The parameters studied were the sensitometric properties, the relative contrast and base plus fog density. These parameters were calculated from values of optical density and the sensitometric properties used also measures of radiation dose. In order to observe the behavior of the films in fresh and degraded solutions, a model of degradation was created that lasted four weeks. The quality parameters were measured at five different times and the results showed that the Contrast® film has sensitivity, contrast and base plus fog density significantly higher, whereas the values of latitude are minor. The relative contrast showed no significant difference between the types of film. The degradation time of processing solutions were not significant in the parameters studied. It was concluded that the claims of the manufacturer of the film Contrast® is correct and confirm the characteristics of film, the highest sensitivity and contrast that the Insight® film / A utilização de radiografias intrabucais é bastante comum na prática diária da Odontologia e o filme radiográfico tem sido o meio mais usado de captura, disposição e armazenamento das imagens radiográficas. Entretanto, as radiações X podem produzir efeitos biológicos deletérios. Uma das formas mais simples de reduzir a radiação que chega ao paciente é o uso de filmes mais sensíveis. A escolha desses filmes é essencial, desde que a qualidade radiográfica não seja prejudicada. Os filmes apresentam comportamentos diferentes frente às variações do tipo de processamento, concentração, temperatura e ao estado de degradação de soluções processadoras. O presente estudo teve como objetivo avaliar o filme DFL Contrast® FV-58 de sensibilidade F e compará-lo com o filme Kodak Insight®, de sensibilidade E/F. Os parâmetros estudados foram as propriedades sensitométricas, o contraste relativo e a densidade base e velamento. Esses parâmetros foram calculados a partir de valores de densidade óptica e o cálculo das propriedades sensitométricas também se utilizou de medidas de dose de radiação. Com a finalidade de observar o comportamento dos filmes em soluções frescas e degradadas, foi criado um modelo de degradação que durou quatro semanas. Os parâmetros de qualidade foram medidos em cinco tempos distintos e os resultados mostraram que o filme Contrast® possui valores de sensibilidade, contraste e densidade base e velamento significativamente maiores, enquanto os valores de latitude são menores. O contraste relativo não mostrou diferença significativa entre os tipos de filme. O tempo de degradação das soluções de processamento não mostrou significância nos parâmetros estudados. Concluiu-se que as alegações do fabricante do filme Contrast® estão corretas e confirmam as características desse filme, de maior sensibilidade e contraste que o filme Insight®.
3

Avaliação da influência do calor e da luz solar na densidade de filmes radiográficos impressos / Evaluation of the influence of heat and sunlight on density of printed radiographic films

Frazão, Marco Antonio Gomes, 1975- 22 August 2018 (has links)
Orientador: Frab Norberto Bóscolo / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-22T13:39:06Z (GMT). No. of bitstreams: 1 Frazao_MarcoAntonioGomes_D.pdf: 4262109 bytes, checksum: 0e3256f8a0dd02738990d526d5a2329b (MD5) Previous issue date: 2012 / Resumo: Com este estudo, teve-se a proposta de avaliar a modificação da densidade de 4 cores (branco, cinza claro, cinza escuro e preto) em filmes radiográficos impressos por duas tecnologias dry seca: termográfica (AGFA) e fototermográfica (KODAK). Para isso, foi utilizada uma amostra formada por 18 grupos com 6 corpos de prova para cada uma das tecnologias de impressão totalizando um experimento com 216 corpos de prova submetidos às temperaturas de 40ºC, 60ºC e 80ºC, pelos tempos de 30, 60 e 120 minutos com e sem a exposição solar. Nestes foram realizadas analises densitométricas antes e depois da exposição aos fatores estudados e os dados obtidos submetidos aos testes estatísticos de: Kruskal Wallis, Mann-Whitney e Wilcoxon para dados pareados com nível de significância de 5%. Pôde-se observar que as cores avaliadas impressas no filme pela tecnologia termográfica (AGFA) modificam sua densidade a partir de combinações de exposição a 60ºC e 120 minutos e a 80ºC e 30 minutos sem a exposição ao sol e a partir de 40ºC e 30 minutos com exposição solar, e no filme impresso pela tecnologia fototermográfica (KODAK) modifica sua densidade a 40ºC a partir de 30 minutos com e sem a exposição solar. Concluiu-se que o aumento da temperatura de armazenamento bem com a exposição à luz solar modificam a densidade dos filmes radiográficos impressos pelas tecnologias dry seca avaliadas / Abstract: The purpose of this study was to evaluate the density modification of 4 colors (white, light gray, dark gray and black) in films printed by two dry technologies: thermographic (AGFA) and photothermographic (KODAK). A sample consisting of 18 groups with six specimens per printing technologies was used, totaling an experiment of 216 evaluated specimens when subjected to temperatures of 40°C, 60°C and 80°C, for periods of 30, 60 and 120 minutes with and without sunlight exposure. These specimens were submitted to densitometric analysis before and after exposure to the studied factors and data were subjected to the following statistical tests: Kruskal Wallis, Mann-Whitney and Wilcoxon for paired data. It was observed that the evaluated colors printed on the film by thermographic technology (AGFA) modify their density at exposures to 60°C and 120 minutes, and without sunlight exposure at the temperature of 80°C after 30 minutes, and with sunlight exposure from 40°C and 30 minutes, and the film printed by photothermographic technology (KODAK) modifies its density at 40°C from 30 minutes with and without sunlight exposure. It was concluded that the increase of storage temperature and sunlight exposure modify the density of radiographic films printed by dry technologies / Doutorado / Radiologia Odontologica / Doutor em Radiologia Odontológica

Page generated in 0.0477 seconds