• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 8
  • 3
  • 2
  • Tagged with
  • 13
  • 13
  • 13
  • 9
  • 9
  • 7
  • 6
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

"Estudo comaparativo das densidades radiográficas de diferentes filmes periapicais obtidas por meio da análise computadorizada em valores de alumínio-equivalente" / Comparison of radiographic densities from different dental intraoral x-ray films by computed analysis into aluminium-equivalent values

Varoli, Felipe Paes 02 July 2004 (has links)
RESUMO O objetivo deste estudo foi obter as densidades radiográficas de diferentes filmes periapicais por meio de um programa computadorizado que utiliza a imagem equivalente em alumínio (alumínio-equivalente). Avaliaram-se os filmes Agfa Dentus M2 “Comfort", Kodak InSight, Kodak Ektaspeed Plus, Kodak Ultra-speed e Kodak D. Todos foram expostos aos raios X juntamente com um escalímetro de Alumínio, variando-se o tempo de exposição (0,1 a 1 segundo). Após a leitura das densidades radiográficas construiu-se um gráfico para compararmos as propriedades sensitométricas dos filmes. O filmes mais sensíveis foram o Agfa Dentus M2 “Comfort" e o Kodak InSight, e os menos sensíveis o Kodak Ultra-speed e o Kodak D. Os filmes Agfa Dentus M2 “Comfort" e Kodak InSight apresentaram os maiores contrastes. Os resultados obtidos por este método indicam que deve-se utilizar os filmes Agfa Dentus M2 “Comfort" e Kodak InSight para reduzir a dose de radiação recebida pelo paciente. / ABSTRACT The aim of this study was to obtain radiographic densities from different dental intraoral x-ray films through a software using aluminium-equivalent image. The densities had been measured in order to compare dental x-ray films in terms of speed, base plus fog, and contrast. Agfa Dentus M2 “Comfort", Kodak InSight, Kodak Ektaspeed Plus, Kodak Ultra-speed and Kodak D-speed films were evaluated. All films were exposed together with aluminium wedge, at times ranging from 0,1-1 second. By plotting a graphic of density against exposure, sensitometric properties were compared. Agfa Dentus M2 “Comfort" and Kodak InSight films obtained the highest film speed; Kodak Ultra-speed and Kodak D-speed films exhibited the lowest sensitivity. Agfa Dentus M2 “Comfort" and Kodak InSight films had presented valuesm to contrast superior to other films. Therefore, Agfa Dentus M2 “Comfort" and Kodak InSight films must be recommended to minimize the radiation dose to the patient.
2

Contribuição para o estudo das densidades base e velamento de diferentes filmes radiográficos submetidos aos processamentos automáticos Roller e Nonroller / Contribution to the study of base-plus-fog densities assessed from radiographic films in roller and nonroller machines

Giannakopoulos, Rodolfo 05 July 2004 (has links)
Objetivos: Comparar as densidades base e velamento de quatro filmes radiográficos: Ultra-speed; D; E e Insight (Eastman Kodak Company, Rochester, E.U.A.) utilizando-se os processamentos automáticos roller e nonroller. Métodos:Tabela comparativa foi construída para os quatro filmes utilizando-se duas condições de processamento e a mesma solução processadora (Kodak Readymatic). Todos os filmes foram processados automaticamente utilizando-se o equipamento AT2000 (Air Techniques, Hicksville, E.U.A.) com velocidade normal e Periomat (Dürr Dental, Bietigheim-Bissingen, Alemanha). Análise comparativa foi realizada para avaliar a densidade base e velamento para cada filme e processadora. Resultados: As maiores densidades base e velamento, foram alcançadas nos três filmes (Ultra-speed, E e Insight) utilizando-se o equipamento AT2000 com velocidade normal. A maior DBV para o filme D foi observada utilizando-se a processadora Periomat. Conclusões: O filme Insight deve ser processado utilizando-se o sistema roller (AT2000) com velocidade normal para alcançar densidade base e velamento ideal. A utilização da Periomat causa redução da DBV para os filmes Ultra-speed, E e Insight. O filme D é o único que apresenta aumento da DBV neste sistema nonroller. / Objectives: To compare base-plus-fog densities of four radiographic films: Ultra-speed, D-Speed; E-Speed and Insight (Eastman Kodak Company, Rochester, USA) using roller and nonroller machines. Methods: Comparative table was constructed for four films using two different processing conditions and the same processing solution (Kodak Readymatic). All films were automatically processed using AT2000 machine (Air Techniques, Hicksville, USA) in normal speed and Periomat machine (Dürr Dental, Bietigheim-Bissingen, Germany). Comparative analysis had been performed to evaluate the base-plus-fog density to each film. Results: Greater base-plus- fog densities were reached in three films (Ultra-speed, E and Insight) using the equipment AT2000 in normal speed. The greater BPFD to D film had been observed to the Periomat machine. Conclusions: The Insight film has to be processed using the roller machine (AT2000) in normal speed to achieve optimal base-plus-fog density. The use of Periomat had caused reduction in BPFD to Ulra-speed, E and Insight films. The D film is the unique that presents increasing in BPFD in this nonroller system.
3

An in-vitro comparison of working length determination between a digital system and conventional film when source-film/sensor distance and exposure time are modified

Ley, Paul J. January 2009 (has links)
Thesis (M.S.D.)--Indiana University School of Dentistry, 2009. / Title from PDF t.p. (viewed Aug. 11, 2009) Advisors: Mychel Vail, Chair of the Research Committee, Susan Zunt, Ted Parks, Kenneth Sponik, Joseph Legan. Curriculum vitae. Includes abstract. Includes bibliographical references (leaves 103-119).
4

"Estudo comaparativo das densidades radiográficas de diferentes filmes periapicais obtidas por meio da análise computadorizada em valores de alumínio-equivalente" / Comparison of radiographic densities from different dental intraoral x-ray films by computed analysis into aluminium-equivalent values

Felipe Paes Varoli 02 July 2004 (has links)
RESUMO O objetivo deste estudo foi obter as densidades radiográficas de diferentes filmes periapicais por meio de um programa computadorizado que utiliza a imagem equivalente em alumínio (alumínio-equivalente). Avaliaram-se os filmes Agfa Dentus M2 “Comfort”, Kodak InSight, Kodak Ektaspeed Plus, Kodak Ultra-speed e Kodak D. Todos foram expostos aos raios X juntamente com um escalímetro de Alumínio, variando-se o tempo de exposição (0,1 a 1 segundo). Após a leitura das densidades radiográficas construiu-se um gráfico para compararmos as propriedades sensitométricas dos filmes. O filmes mais sensíveis foram o Agfa Dentus M2 “Comfort” e o Kodak InSight, e os menos sensíveis o Kodak Ultra-speed e o Kodak D. Os filmes Agfa Dentus M2 “Comfort” e Kodak InSight apresentaram os maiores contrastes. Os resultados obtidos por este método indicam que deve-se utilizar os filmes Agfa Dentus M2 “Comfort” e Kodak InSight para reduzir a dose de radiação recebida pelo paciente. / ABSTRACT The aim of this study was to obtain radiographic densities from different dental intraoral x-ray films through a software using aluminium-equivalent image. The densities had been measured in order to compare dental x-ray films in terms of speed, base plus fog, and contrast. Agfa Dentus M2 “Comfort”, Kodak InSight, Kodak Ektaspeed Plus, Kodak Ultra-speed and Kodak D-speed films were evaluated. All films were exposed together with aluminium wedge, at times ranging from 0,1-1 second. By plotting a graphic of density against exposure, sensitometric properties were compared. Agfa Dentus M2 “Comfort” and Kodak InSight films obtained the highest film speed; Kodak Ultra-speed and Kodak D-speed films exhibited the lowest sensitivity. Agfa Dentus M2 “Comfort” and Kodak InSight films had presented valuesm to contrast superior to other films. Therefore, Agfa Dentus M2 “Comfort” and Kodak InSight films must be recommended to minimize the radiation dose to the patient.
5

Contribuição para o estudo das densidades base e velamento de diferentes filmes radiográficos submetidos aos processamentos automáticos Roller e Nonroller / Contribution to the study of base-plus-fog densities assessed from radiographic films in roller and nonroller machines

Rodolfo Giannakopoulos 05 July 2004 (has links)
Objetivos: Comparar as densidades base e velamento de quatro filmes radiográficos: Ultra-speed; D; E e Insight (Eastman Kodak Company, Rochester, E.U.A.) utilizando-se os processamentos automáticos roller e nonroller. Métodos:Tabela comparativa foi construída para os quatro filmes utilizando-se duas condições de processamento e a mesma solução processadora (Kodak Readymatic). Todos os filmes foram processados automaticamente utilizando-se o equipamento AT2000 (Air Techniques, Hicksville, E.U.A.) com velocidade normal e Periomat (Dürr Dental, Bietigheim-Bissingen, Alemanha). Análise comparativa foi realizada para avaliar a densidade base e velamento para cada filme e processadora. Resultados: As maiores densidades base e velamento, foram alcançadas nos três filmes (Ultra-speed, E e Insight) utilizando-se o equipamento AT2000 com velocidade normal. A maior DBV para o filme D foi observada utilizando-se a processadora Periomat. Conclusões: O filme Insight deve ser processado utilizando-se o sistema roller (AT2000) com velocidade normal para alcançar densidade base e velamento ideal. A utilização da Periomat causa redução da DBV para os filmes Ultra-speed, E e Insight. O filme D é o único que apresenta aumento da DBV neste sistema nonroller. / Objectives: To compare base-plus-fog densities of four radiographic films: Ultra-speed, D-Speed; E-Speed and Insight (Eastman Kodak Company, Rochester, USA) using roller and nonroller machines. Methods: Comparative table was constructed for four films using two different processing conditions and the same processing solution (Kodak Readymatic). All films were automatically processed using AT2000 machine (Air Techniques, Hicksville, USA) in normal speed and Periomat machine (Dürr Dental, Bietigheim-Bissingen, Germany). Comparative analysis had been performed to evaluate the base-plus-fog density to each film. Results: Greater base-plus- fog densities were reached in three films (Ultra-speed, E and Insight) using the equipment AT2000 in normal speed. The greater BPFD to D film had been observed to the Periomat machine. Conclusions: The Insight film has to be processed using the roller machine (AT2000) in normal speed to achieve optimal base-plus-fog density. The use of Periomat had caused reduction in BPFD to Ulra-speed, E and Insight films. The D film is the unique that presents increasing in BPFD in this nonroller system.
6

Comparação de sistemas digitais e filme radiografico convencional no diagnostico de caries proximais em esmalte

Pontual, Andrea dos Anjos 24 February 2005 (has links)
Orientador: Francisco Haiter Neto / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-04T03:47:02Z (GMT). No. of bitstreams: 1 Pontual_AndreadosAnjos_M.pdf: 23672659 bytes, checksum: 557d0af196a3b37022ea269439130873 (MD5) Previous issue date: 2005 / Resumo: O objetivo nesse trabalho foi avaliar a eficácia dos sistemas digitais Digora®, com as placas de fósforo branca e azul, e DenOptix®, assim como do filme radiográfico Insight®, na detecção de cáries proximais incipientes em esmalte, comparando os resultados obtidos na avaliação radiográfica com a mensuração histológica de extensão destas lesões. Em seguida, foi verificado se o aumento da extensão da lesão cariosa acarretaria maior detecção radiográfica das mesmas. Foram obtidas imagens interproximais de 20 phantoms, constituídos de dentes humanos, que foram avaliadas por 17 cirurgiões-dentistas quanto à presença e extensão de lesões cariosas por meio da atribuição de escores. Posteriormente, os dentes foram seccionados e analisados microscopicamente para obtenção do padrão ouro. As faces que apresentaram cárie em esmalte, 64 (42,1%), foram avaliadas quanto a sua extensão na camada de esmalte. Utilizou-se o teste de Friedman (p<0,05) para verificar se existiu diferença estatisticamente significativa entre a moda das avaliações radiográficas das modalidades de imagem e entre estas e o padrão ouro. Foi aplicado o teste não-paramétrico de comparações múltiplas (p<0,05), para revelar quais métodos em questão apresentaram diferença estatisticamente significativa. Os resultados não mostraram diferenças estatisticamente significativas entre os sistemas digitais e o filme radiográfico no diagnóstico de cáries proximais em esmalte, entretanto, todas as modalidades de imagem foram diferentes do padrão ouro. Na comparação das avaliações radiográficas com a extensão da lesão de cárie em relação à camada de esmalte, observou-se que aumento da extensão da lesão cariosa não acarretou maior detecção radiográfica / Abstract: The aim of this study was to evaluate the efficacy of the digital systems Digora®, with white and blue phosphor plates, and DenOptix®, as well as of the radiographic film Insight®, for detection of incipient proximal caries in enamel, comparing the results achieved in the radiographic evaluation with histological measurement of the extension of these lesions. Thereafter, it was observed whether the increase in the extension of the carious lesion would increase their radiographic detection. Interproximal images were achieved from 20 phantoms, composed of human teeth, which were evaluated by 17 dental professionals as to the presence and extension of carious lesions by assigning scores. Then, the teeth were sectioned and microscopically analyzed for achievement of the gold standard. The surfaces presenting enamel caries, 64 (42.1%), were evaluated as to their extension in the enamel layer. The Friedman test was used (p<0.05) to check if there was a statistically significant difference between the mode of the radiographic evaluations of each type of image and between them and the gold standard. The nonparametric test for multiple comparisons was applied (p<0.05) to reveal which methods analyzed presented a statistically significant difference. The results did not demonstrated statistically significant differences between the digital systems and the radiographic film for diagnosis of proximal caries in enamel; however, all types of image were different from the gold standard. Comparison between the radiographic evaluations and the extension of the carious lesion in relation to the enamel layer revealed that the increase in extension of the carious lesion did not increase the radiographic detection / Mestrado / Radiologia Odontologica / Mestre em Radiologia Odontológica
7

Avaliação do tempo de secagem e da qualidade da imagem de radiografias submetidas a banho em alcool etilico em diferentes concentraçãoes / Evaluation of drying period and quality of image of radiographs submitted to immersion in ethyl alcohol at different concentrations

Damian, Melissa Feres 28 February 2005 (has links)
Orientador: Francisco Haiter Neto / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-04T04:03:37Z (GMT). No. of bitstreams: 1 Damian_MelissaFeres_D.pdf: 735238 bytes, checksum: 0d3e3519a1b631b044005442d3fbbf3e (MD5) Previous issue date: 2005 / Resumo: Com este estudo, teve-se a proposta de avaliar a ação do álcool etílico, nas concentrações de 46ºGL, 70ºGL e 92ºGL, como agente acelerador da secagem de radiografias dentárias, a fim de abreviar o tempo de processamento. Adicionalmente, foi verificado se esse produto poderia causar alterações na dens idade, nas propriedades sensitométricas e na qualidade destas radiografias após um curto período de arquivamento. Para tanto, foram utilizados os filmes radiográficos intra-orais de sensibilidade D (Dspeed), E (E-speed) e E/F (Insight) da Kodak, divididos em grupos de acordo com o uso e a concentração da substância alcoólica. Todos os filmes foram processados manualmente pelo método temperatura/tempo em câmara escura portátil para simular condições clínicas. As radiografias foram submetidas às analises densitométrica e clínica subjetiva, além da construção de curvas características para a obtenção do contraste e da sensibilidade, nos períodos correspondentes a um e seis meses após a realização do experimento, simulando condições de arquivo. Pôde-se observar que o uso do álcool etílico acelerou a secagem das radiografias independentemente do tipo de filme, sendo que o menor tempo foi obtido com a utilização da substância alcoólica de maior concentração. Contudo, os valores de densidade, contraste e sensibilidade foram alterados quando foi utilizado o álcool 70ºGL e o álcool 92ºGL, sendo que este último também foi capaz de alterar a qualidade visual das imagens. Tais alterações puderam ser visualizadas nos dois períodos de avaliação de estudo. Assim, concluiu -se que mesmo que o álcool etílico acelere a secagem das radiografias, sua utilização causou alterações capazes de prejudicar a qualidade da imagem, inclusive após um curto período de arquivamento / Abstract: This study evaluated the action of ethyl alcohol at concentrations of 46ºGL, 70ºGL and 92ºGL as an accelerator of drying of dental radiographs, with a view to reduce the time required for processing. Also, it was observed whether this product might cause alterations in the density, sensitometric properties and quality of these radiographs after a 6- month storage period. For that purpose, intraoral radiographic films D-speed, E-speed and E/F (Insight) of Kodak were employed, which were divided into groups according to the utilization and concentration of the alcoholic substance. All films were developed manually by the time-temperature method in a portable dark room, to simulate the clinical conditions. The radiographs were submitted to densitometric and clinical analyses, besides construction of characteristic curves for achievement of contrast and sensitivity, at periods corresponding to one and six months after accomplishment of the study, simulating conditions of storage. It was observed that the utilization of ethyl alcohol accelerated the drying of radiographs, regardless of the type of film; the shortest time was achieved with utilization of the alcoholic substance of highest concentration. However, the density, contrast and speed of radiographs were altered when concentrations of 70ºGL and 92ºGL were used; being that the latter also altered the visual quality of images. Such alterations could be observed at the two evaluations and study periods. Thus, it was concluded that, even though the ethyl alcohol may accelerate the drying of radiographs, its utilization caused alterations able to impair the quality of image, even after a short period of storage / Doutorado / Radiologia Odontologica / Doutor em Radiologia Odontológica
8

An in vitro comparison of working length accuracy between a digital system and conventional film when vertical angulation of the object is variable

Christensen, Shane R. January 2009 (has links)
Thesis (M.S.D.)--Indiana University School of Dentistry, 2009. / Title from PDF t. p. (viewed Aug. 21, 2009) Advisor(s): Mychel Vail, Acting Chair of the Research Committee, Joseph Legan, Kenneth Spolnik, Susan L. Zunt, Edwin Parks. Curriculum vitae. Includes abstract. Includes bibliographical references (leaves 109-120).
9

Avaliação objetiva da qualidade do filme Contrast® FV-58 em soluções frescas e degradadas

Carvalho, Fabiano Pachêco de 10 December 2009 (has links)
Made available in DSpace on 2015-05-14T12:56:05Z (GMT). No. of bitstreams: 1 arquivototal.pdf: 1129487 bytes, checksum: 9b4bcacf33a745b3f606911583f777bb (MD5) Previous issue date: 2009-12-10 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / The use of intraoral radiographs is quite common in daily practice of dentistry and the radiographic film has been the most used means of capture, disposal and storage of radiographic images. However, X-ray emission can produce deleterious biological effects. One of the easiest ways to reduce the radiation needed to produce radiographs is the use of more sensitive films. The choice of these films is essential, since the radiographic quality is not compromised. The films have different behaviors in the changing of the type of processing, concentration, temperature and state of degradation of processing solutions. This study aimed to evaluate the F-speed film DFL Contrast® FV-58 and compare it with the Kodak Insight® E/F speed film. The parameters studied were the sensitometric properties, the relative contrast and base plus fog density. These parameters were calculated from values of optical density and the sensitometric properties used also measures of radiation dose. In order to observe the behavior of the films in fresh and degraded solutions, a model of degradation was created that lasted four weeks. The quality parameters were measured at five different times and the results showed that the Contrast® film has sensitivity, contrast and base plus fog density significantly higher, whereas the values of latitude are minor. The relative contrast showed no significant difference between the types of film. The degradation time of processing solutions were not significant in the parameters studied. It was concluded that the claims of the manufacturer of the film Contrast® is correct and confirm the characteristics of film, the highest sensitivity and contrast that the Insight® film / A utilização de radiografias intrabucais é bastante comum na prática diária da Odontologia e o filme radiográfico tem sido o meio mais usado de captura, disposição e armazenamento das imagens radiográficas. Entretanto, as radiações X podem produzir efeitos biológicos deletérios. Uma das formas mais simples de reduzir a radiação que chega ao paciente é o uso de filmes mais sensíveis. A escolha desses filmes é essencial, desde que a qualidade radiográfica não seja prejudicada. Os filmes apresentam comportamentos diferentes frente às variações do tipo de processamento, concentração, temperatura e ao estado de degradação de soluções processadoras. O presente estudo teve como objetivo avaliar o filme DFL Contrast® FV-58 de sensibilidade F e compará-lo com o filme Kodak Insight®, de sensibilidade E/F. Os parâmetros estudados foram as propriedades sensitométricas, o contraste relativo e a densidade base e velamento. Esses parâmetros foram calculados a partir de valores de densidade óptica e o cálculo das propriedades sensitométricas também se utilizou de medidas de dose de radiação. Com a finalidade de observar o comportamento dos filmes em soluções frescas e degradadas, foi criado um modelo de degradação que durou quatro semanas. Os parâmetros de qualidade foram medidos em cinco tempos distintos e os resultados mostraram que o filme Contrast® possui valores de sensibilidade, contraste e densidade base e velamento significativamente maiores, enquanto os valores de latitude são menores. O contraste relativo não mostrou diferença significativa entre os tipos de filme. O tempo de degradação das soluções de processamento não mostrou significância nos parâmetros estudados. Concluiu-se que as alegações do fabricante do filme Contrast® estão corretas e confirmam as características desse filme, de maior sensibilidade e contraste que o filme Insight®.
10

Avaliação da influência do calor e da luz solar na densidade de filmes radiográficos impressos / Evaluation of the influence of heat and sunlight on density of printed radiographic films

Frazão, Marco Antonio Gomes, 1975- 22 August 2018 (has links)
Orientador: Frab Norberto Bóscolo / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-22T13:39:06Z (GMT). No. of bitstreams: 1 Frazao_MarcoAntonioGomes_D.pdf: 4262109 bytes, checksum: 0e3256f8a0dd02738990d526d5a2329b (MD5) Previous issue date: 2012 / Resumo: Com este estudo, teve-se a proposta de avaliar a modificação da densidade de 4 cores (branco, cinza claro, cinza escuro e preto) em filmes radiográficos impressos por duas tecnologias dry seca: termográfica (AGFA) e fototermográfica (KODAK). Para isso, foi utilizada uma amostra formada por 18 grupos com 6 corpos de prova para cada uma das tecnologias de impressão totalizando um experimento com 216 corpos de prova submetidos às temperaturas de 40ºC, 60ºC e 80ºC, pelos tempos de 30, 60 e 120 minutos com e sem a exposição solar. Nestes foram realizadas analises densitométricas antes e depois da exposição aos fatores estudados e os dados obtidos submetidos aos testes estatísticos de: Kruskal Wallis, Mann-Whitney e Wilcoxon para dados pareados com nível de significância de 5%. Pôde-se observar que as cores avaliadas impressas no filme pela tecnologia termográfica (AGFA) modificam sua densidade a partir de combinações de exposição a 60ºC e 120 minutos e a 80ºC e 30 minutos sem a exposição ao sol e a partir de 40ºC e 30 minutos com exposição solar, e no filme impresso pela tecnologia fototermográfica (KODAK) modifica sua densidade a 40ºC a partir de 30 minutos com e sem a exposição solar. Concluiu-se que o aumento da temperatura de armazenamento bem com a exposição à luz solar modificam a densidade dos filmes radiográficos impressos pelas tecnologias dry seca avaliadas / Abstract: The purpose of this study was to evaluate the density modification of 4 colors (white, light gray, dark gray and black) in films printed by two dry technologies: thermographic (AGFA) and photothermographic (KODAK). A sample consisting of 18 groups with six specimens per printing technologies was used, totaling an experiment of 216 evaluated specimens when subjected to temperatures of 40°C, 60°C and 80°C, for periods of 30, 60 and 120 minutes with and without sunlight exposure. These specimens were submitted to densitometric analysis before and after exposure to the studied factors and data were subjected to the following statistical tests: Kruskal Wallis, Mann-Whitney and Wilcoxon for paired data. It was observed that the evaluated colors printed on the film by thermographic technology (AGFA) modify their density at exposures to 60°C and 120 minutes, and without sunlight exposure at the temperature of 80°C after 30 minutes, and with sunlight exposure from 40°C and 30 minutes, and the film printed by photothermographic technology (KODAK) modifies its density at 40°C from 30 minutes with and without sunlight exposure. It was concluded that the increase of storage temperature and sunlight exposure modify the density of radiographic films printed by dry technologies / Doutorado / Radiologia Odontologica / Doutor em Radiologia Odontológica

Page generated in 0.0596 seconds