• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Improvements and Validation of THUMS Upper Extremity : Refinements of the Elbow Joint for Improved Biofidelity / Utveckling och validering av THUMS övre extremitet : Förfining av armbågen för bättre biofidelitet

Sverrisdóttir, Kristín January 2019 (has links)
Introduction One out of five reported motor vehicle collision injuries occur to the upper extremities. Certain parts of The Total HUman Model for Safety (THUMS) lack validation against experimental data, including the elbow. The aim of this project is to refine and validate the elbow joint of THUMS, with focus on anatomical response of the elbow during axial impact applied to the wrist. Methods Internal contacts in the elbow were modified and new contacts assigned between bones and ligaments of the elbow. The posterior part of the radial- and ulnar collateral ligaments, and joint capsule was implemented to the model. Elasticmodulus of the cortical bones of the elbow was increased as well as the shell thickness of the humeral cortical bone. The updated model was validated against an experiment where an axial load was applied to the wrist of a female cadaver. The experimental resultant force in the wrist was then compared with the wrist force obtained from the simulations. Results The correlation between the experimental and simulation resultant wrist force for the updated model resulted in a CORA score of 0.882. This gave a 6.7% higher CORA score compared with the original model. Hourglass energy was reduced from 63.52% of internal energy to 0.78%. Energy ratio and contact energies indicated that the simulation was stable. Discussion Movement of elbow bones was assessed to be more anatomically correct, by accounting for the posterior ligament and elbow capsule support. The contact peak force in the humerus was lower and occurred earlier in the simulation in the updated model compared to the original. This is believed to be due to the reduced gap between the elbow bones after increasing the shell thickness of the humeral cortical bone. The model setup resembled the experiment in a good manner. Conclusion The upper extremity of THUMS was refined for improved biofidelity, with focus on the anatomical response of the elbow joint under an axial impact. However, further model improvements are suggested as well as extended validated against other experimental impact results. / Introduktion En av fem rapporterade krockskador med motorfordon förekommer i de övre extremiteterna. Vissa strukturer hos Total HUman Model for Safety (THUMS) saknar validering gentemot experimentell data, där armbågen är ett av dem. Syftet med detta projekt är att förfina och validera armbågsleden hos THUMS, med fokus på dess anatomiska respons under axiellt islag applicerad på handleden. Metod Interna kontakter i armbågen modifierades och nya kontakter tilldelades mellan ben och ligament. De posteriora delarna av kollateral ligament hos radius och ulna implementerades i modellen, så även armbågens ledkapseln. Elasticitetsmodulen hos de kortikala benen i armbågen höjdes och skalets tjocklek idet humerala kortikala benet utökades. Den uppdaterade modellen validerades mot ett experiment där en axiell belastning hade applicerats mot en kvinnlig kadavers handled. Den resulterande kraften i handleden från experimentet jämfördes sedan med erhållen kraft i handleden från simuleringarna. Resultat Korrelationen mellan den experimentella kraften och simulerade kraften hos den uppdaterade modellen resulterade i ett CORA-poäng på 0,882. Detta är en ökning med 6,7% jämfört med den ursprungliga modellen. Hourglassenergin reducerades från 63,52% av inre energi till 0,78%. Energiförhållandet och kontaktenergier indikerade stabil simulering. Diskussion Rörelsen av armbågens ben bedömdes vara mer anatomiskt korrekt, med hänsyn till stödet från de posteriora ligamentet och armbågens ledkapsel. Den maximala islagskraften i humerus minskade och uppträdde tidigare i simuleringen hos den uppdaterade modellen jämfört med originalet. Detta tros bero på reducerat avstånd mellan armbågens ben genom ökandet av skaltjockleken hos det humeralakortikala benet. Modelluppställningen motsvarade experimentets uppställning. Konklusion De övre extremiteterna av THUMS förfinades i syfte att förbättra biofideliteten. Fokus låg på armbågens anatomiska respons under ett axielltislag. Både ytterligare förbättringar av modellen och utökad validering mot andra experimentella islag rekommenderas. / Technology
2

Arm Injury Prediction with THUMS SAFER: Improvements of the THUMS SAFER upper extremity / Förutsägelse av armskada med THUMS SAFER: Förbättringar av THUMS SAFER över extremitet

Bayat, Mariam, Pongpairote, Nichakarn January 2020 (has links)
Globally, approximately 1.2 million people die each year due to traffic accidents. Upper extremity injuries account for 18% to 25% of all car accident injuries. In order to be able to analyze these crash-related injuries, Human body models(HBMs) are used as a complement to FE simulations. An example of a HBM is the THUMS SAFER that is based on a 50 percentile American male. The aim of this study was to improve the upper extremity of the THUMS SAFER with respect to Autoliv's requirements to better predict fractures. In addition, this was validated against the Forman experiment(Forman, et al., The journal of trauma and acute care surgery, vol. 77, 2014) where human cadavers of the upper extremity were axially impacted to replicate a car collision. This was done by generating the upper extremity geometry with segmentation of medical images of a right human hand in combination with the complete STL-geometry of the forearm from the Piper project. The STL-geometry of the segmented human hand and Piper forearm was integrated and a complete STL-geometry of the upper extremity was obtained. Based on the complete STL-geometry, the FE-arm HEX 4.0 was built with modelling of bones, ligaments, soft tissue and skin with corresponding material choice in accordance with Autoliv's requirements. The model HEX 4.0 was improved considering an increased mesh density from an average of 94% to 98%. HEX 4.0 was also validated against the data from the Forman experiment for experiments 5, 6 and 15. It showed a good correlation with the acceleration curves between the simulated and experimental values for the three experiments. The reaction force in the elbow was compared for experiment 15, where the simulated value 5.7 kN divided by a factor of 1.4 from 4 kN for the experiment. Furthermore, the fi rst principal strains that occurred in HEX 4.0 were analysed by 17 ms were the highest acceleration was achieved for experiments 5 and 6. Both experiments were shown to be close to the failure threshold of bones. However, the highest value e5=9.8E-03 occurred in the radius for experiment 5, while e6=9.3E-03 in a ligament for experiment 6. In addition, the failure threshold for experiment 15 exceeded 5 ms in lunate, schapoid and triquetrum. This indication of fractures is in good agreement with the experimental results where the corresponding bones resulted in fractures in experiment 15. HEX 4.0 was an improved upper extremity of the THUMS SAFER considering an increased mesh density. It is also capable of indicating fractures and corresponding positions in the form of analyzes of occurring stresses and strains. Nevertheless, improvements and further validation of HEX 4.0 has been proposed in the future work section. / Globalt, dör varje år ungefär 1.2 miljoner personer på grund av trafi kolyckor. Skador på övre extremitet utgör 18% till 25% av alla skador inom bilolyckor. För att kunna analysera dessa krockrelaterade skador används humanmodeller(HBM) som komplement för FE-simuleringar. Ett exempel på en HBM är THUMS SAFER som är baserad på en "50 percentile" amerikans man. Målet med denna studie är att förbättra över extremiten av THUMS SAFER med avseende på Autolivs krav för att bättre kunna förutspå frakturer. Dessutom validerades detta mot Forman experiment(Forman, et al., The journal of trauma and acute care surgery, vol. 77, 2014) där övre extremitet av människokadaver blev axiellt påverkade för att replikera en bilkollsion. Detta gjordes genom att generera STL-geometrin av en övre extremitet med segmentering av medicinska bilder av en höger människohand i kombination med färdig STL-geometri av underarmen från Piper projektet. STL-geometrin av den segmenterande människohanden och Piper underarmen integrerades och en komplett STL-geometri av övre extremiteten erhölls. Baserad på den kompletta STL-geometrin byggdes FE-armen HEX 4.0 med modellering av ben, ligament, mjukvävnad samt hud med motsvarande materialval i enighet med Autolivs krav. Modellen HEX 4.0 förbättrades i form av en ökad mesh densitet från medelvärdet 94% till 98%. Den validerades även gentemot data från Forman experimentet för experiment 5, 6 och 15. Det påvisade en god korrelation på accelerations kurvorna mellan de simulerade och experimentella värdena för de tre experimenten. Reaktionskraften i armbågen jämfördes för experiment 15 där den simulerade värdet 5.7 kN skiljde sig med en faktor 1.4 från 4 kN för experimentet. Ytterligare analyserades första huvudtöjningarna som uppkom i HEX 4.0 vid 17 ms, då den högsta accelerationen uppnådes för experiment 5 och 6. Det visades att båda experimenten låg nära gränsen för benfraktur, däremot uppkom det högsta värdet e5=9.8E-03 i radius för experiment 5, samt e6=9.3E-03 i ett ligament för experiment 6. Dessutom överskred gränsen för benfrakturer för experiment 15 efter 5 ms i lunate, schapoid och triquetrum. Denna indikation av frakturer stämmer väl med resultatet av experimentet där motsvarande benen resulterades i frakturer i experiment 15. HEX 4.0 är en förbättrad övre extremitet av THUMS SAFER i form av förbättrad meshdensitet. Den är även kapabel att indikera frakturer och motsvarande position i form av analyser på förekommande spänningar och töjningar. Förbättringar och ytterligare validering av HEX 4.0 föreslås för framtida arbete.

Page generated in 0.1309 seconds