• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 15
  • 1
  • Tagged with
  • 16
  • 12
  • 8
  • 8
  • 4
  • 4
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Uso do Método dos Elementos Finitos na avaliação das propriedades mecânicas de um fixador externo / not available

Vilarinho, Claudio Cesar Rodrigues 26 September 2000 (has links)
Este trabalho avaliou, utilizando o Método dos Elementos Finitos, o comportamento mecânico em seis ensaios, quatro de flexo compressão com variação apenas no comprimento da haste de fixação, um de flexão ântero-posterior e um de flexão lateral, em um modelo tridimensional de fixador externo construído com auxílio do computador. Para a validação desses ensaios os mesmos testes também foram realizados na máquina universal de ensaio e depois comparados com o método dos elementos finitos. A rigidez no ensaio de flexão lateral obtida no método dos elementos finitos apresentou um valor 106% maior do que o obtido na máquina universal de ensaio, possivelmente por ocorrência de afrouxamento entre as partes adjacentes elo fixador externo no ensaio mecânico, e no ensaio de flexo compressão (número 1) a rigidez obtida pelo método dos elementos finitos foi 7,39% menor elo que a obtida na máquina universal de ensaio. No ensaio número 4 (flexo-compressão) os deslocamentos obtidos, correspondentes a aplicação de uma carga de 15,4 N, utilizando tanto o método dos elementos finitos como a máquina universal ele ensaio, divergiram em 8,5%. Já no ensaio número 5 (flexão ântero-posterior) a divergência foi de 0,9%, para os deslocamentos correspondentes a aplicação de uma carga de 14,4 N. O Métodos dos Elementos Finitos é um eficiente método para prever comportamento mecânico de estruturas complexas. / This work evaluates the mechanical behavior of an external device on a CAD (Computer Aided Design) 3D model in six tests, four of them of flexion-compression with a single variation of the external device stick length, one of longitudinal flexion and one of lateral flexion. They all were carried out applying the Method of the Finite Elements (MFE). For the comparison with the MFE the same mechanical testes were made. The stiffness achieved in the MFE showed a value 106% greater than that of the mechanical test. The test number one of flexion-compression showed a value 7,39% smaller in the MFE than that of the mechanical test. In the test number four (flexion-compression) the corresponding displacement after the application of a 15,4 N working stress showed a difference of 8,5%. The variation of the number five test was of 0,9% for the displacement after the application of a 14,4N working stress. The MEF showed efficient to evaluate the behavior of complex mechanical structures.
2

Simulações computadorizadas de fixadores internos de coluna utilizando o método dos elementos finitos / Computerized internal fixator simulations of column using the method of the finite elements

Santos, Antonio Marcos dos 31 March 2004 (has links)
Os problemas freqüentes de patologias ortopédicas e traumáticas da coluna vertebral envolvem a colocação de fixadores internos (parafusos longos, os quais são inseridos nos pedículos posteriores até os corpos vertebrais e conectados por fios nas hastes longitudinais podendo ser fixados em todas as posições pelas porcas). Estes fixadores foram simulados no computador através da construção de modelos geométricos dos mesmos, utilizando o software ANSYS 5.5, que consiste de várias ferramentas para análise do projeto baseado no método dos elementos finitos. Foi também utilizado um software para a modelagem das peças e do conjunto do fixador já existente chamado SOLID EDGE, e logo em seguida o mesmo foi transferido para o software ANSYS 5.5 e simulado. Esta comparação servirá como complemento para possíveis modificações das montagens, dimensões e aplicações, não necessitando de novos ensaios mecânicos na máquina universal de ensaios e sim realizando simulações computadorizadas / The frequent problems of orthopedic and traumatic pathologies of the spinal column that involves the placement of an internal fixator (long screws, which are inserted in the subsequent pedicle until the vertebral and connected by bodies for wires in the longitudinal stems could be fastened in all the positions by the screw). These fixators were simulate in the computer through the construction of geometric models of the same ones, using the software ANSYS 5.5, that consists of several tools for analysis of the project based on the method of the finite elements. It was also used a software for the modelling of the pieces and of the group of the fixador already called existent SOLID EDGE, and then the same was transferred to the software ANSYS 5.5 and simulated. This comparison will serve a complement for possible modifications of the assemblies, dimensions and applications, not needing new mechanical test in the universal machine test but accomplishing computerized simulations
3

Influência do exercício em esteira na consolidação da osteotomia na tíbia de coelho fixada com fixador externo unilateral / The influence of treadmill exercise on the consolidation of osteotomies, in rabbit tibias treated with unilateral external fixation

Oliveira, Carla Cristina Esteves Silva 17 December 2003 (has links)
Sabe-se que a aplicação de carga influencia na consolidação óssea; e associada ao exercício podem reduzir o tempo de reparação óssea e a permanência com o fixador, que resultaria em muitas vantagens para a prática clínica. O objetivo deste trabalho foi avaliar a influência do exercício em esteira, na consolidação da osteotomia na tíbia de coelhos, tratadas com fixador externo unilateral. O trabalho foi desenvolvido no laboratório de Bioengenharia da Faculdade de Medicina de Ribeirão Preto da USP, utilizando-se 16 coelhos machos adolescentes da raça Nova Zelândia, que foram submetidos a uma osteotomia transversa no terço médio da tíbia e colocação do fixador externo unilateral para fixá-la. Após o procedimento cirúrgico os animais foram divididos em dois grupos: sedentários com n = 10 e exercitados com n = 10 (submetidos a exercícios diários em esteira, com intensidade moderada, durante 10\'). Foi realizada uma avaliação radiográfica no pós-operatório imediato e a cada 10 dias até a oitava semana, quando os animais foram eutanasiados e suas tíbias retiradas e submetidas ao ensaio mecânico de torção. Na avaliação radiográfica observou-se um percentual maior de tíbias consolidadas, num período inferior a 40 dias no grupo exercitado, enquanto que os valores médios das variáveis mecânicas: torque máximo, deformação angular e energia absorvida até a ruptura, não representaram diferença estatística significativa para p menor e igual a 0,05, apesar de ser observada uma tendência para maiores valores de torque no grupo exercitado. Estes resultados sugerem que o exercício não influencia na velocidade e no padrão de consolidação da fratura neste estudo. / It is known that a load application affects bone healing and in association with exercises, it can reduce bone healing time and fixator permanence time, what would result in several advantages in clinical practice. This article is aimed to evaluate the exercises influence on healing in osteotomised tibiae of rabbits fixed unilateral external fixator. This research was developed in the Bioengineering Laboratory of Medical School of Ribeirão Preto - USP. Sexteen young male New Zealand rabbits were submitted to transverse osteotomy in the middle third of the tibia and fixed with unilateral external fixator. After the surgical procedure, animals were divided into 2 groups: sedentary (n = 10) and exercised (n = 10), being the last group submitted to dayly exercises on a mat for 10 minutes with moderate intensity. A radiographic control was made in the immediate post-operative period and every 10 days during the first 8 weeks. After that, animals were euthanized and their tibia were removed and submitted to a torsional test. For the exercised group, there was observed a larger percentage of healed tibia in a period shorter than 40 days in respect to the radiographic control. The means of mechanical variables (maximum torque, angular displacement and energy required to failure) have shown no significant statisticall difference for p less and equal a 0.05, although it was noticed a tendency to higher values of torque in the exercised group. These results suggest no influence of exercises in relation the speed of and fracture healing in this study.
4

Estudio comparativo de la efectividad del tratamiento entre fijador externo y osteosíntesis en las fracturas completas del radio distal (tipo 23-C)

Norberto Bayona, Eduardo 14 March 2001 (has links)
Durante el periodo 1988 - 1991 realizamos una revisión de 300 fracturas de la extremidad distaldel radio tratadas con yeso o combinando el vendaje enyesado con agujas de Kirschnerintrafocales tipo Kapandji. El análisis de los resultados de la documentación clínica de los casos,nos permitió confeccionar un protocolo de tratamiento para estas fracturas, con el fin de podermejorar los resultados del tratamiento ortopédico, que en las fracturas 23-C solo conseguía un20% de buenos resultados.En 1990, por iniciativa de Dr. Rafael Orozco, y bajo la supervisión del Prof. Maurice E. Müllerreclasificamos 54.280 fracturas de los huesos largos tratadas con osteosíntesis, recogidasinformaticamente en el Centro de Documentación de la AO-Internacional (Grupo Internacionalpara el Estudio de la Osteosíntesis), en Berna y Davos (Suiza). El estudio se realizó siguiendo laClasificación de las fracturas de los huesos largos, publicada en 1990 por el Prof. M.E.Müller Müller 90.El motivo que nos animó a realizar este estudio fue que, a nuestra casuística, pudimos añadir unamuestra significativamente importante como la del Centro de documentación de la AO-Internacional, de donde se seleccionaron los casos de fracturas articulares completas distales deradio (tipo 23-C de la Clasificación de M.E. Müller), tratadas con Fijador Externo o con Ostesíntesis.La incidencia encontrada para estas fracturas distales de cúbito y radio (segmento 23-) fue de un5'67 % (3.094 fras.) del total de fracturas documentadas tratadas con osteosíntesis. En nuestroestudio sólo utilizaremos las fracturas 23-C (articulares completas) que son el 42'4 % (1.315 fras.)del segmento 23- tratadas quirúrgicamente. Dentro de este último grupo veremos las tratadas confijador externo o con osteosíntesis-placa.El valor de la muestra estriba en el tamaño de la misma, además de estar clasificada y tratada conunos criterios homogéneos de escuela que permiten su comparación.El interés del estudio radica en la significación de la muestra, por su tamaño, el intervalo de edadde la población implicada, la frecuencia de aparición, el tiempo de incapacidad laboral que supone,las secuelas que comporta y el coste socioeconómico que todo ello representa.
5

Influência do exercício em esteira na consolidação da osteotomia na tíbia de coelho fixada com fixador externo unilateral / The influence of treadmill exercise on the consolidation of osteotomies, in rabbit tibias treated with unilateral external fixation

Carla Cristina Esteves Silva Oliveira 17 December 2003 (has links)
Sabe-se que a aplicação de carga influencia na consolidação óssea; e associada ao exercício podem reduzir o tempo de reparação óssea e a permanência com o fixador, que resultaria em muitas vantagens para a prática clínica. O objetivo deste trabalho foi avaliar a influência do exercício em esteira, na consolidação da osteotomia na tíbia de coelhos, tratadas com fixador externo unilateral. O trabalho foi desenvolvido no laboratório de Bioengenharia da Faculdade de Medicina de Ribeirão Preto da USP, utilizando-se 16 coelhos machos adolescentes da raça Nova Zelândia, que foram submetidos a uma osteotomia transversa no terço médio da tíbia e colocação do fixador externo unilateral para fixá-la. Após o procedimento cirúrgico os animais foram divididos em dois grupos: sedentários com n = 10 e exercitados com n = 10 (submetidos a exercícios diários em esteira, com intensidade moderada, durante 10\'). Foi realizada uma avaliação radiográfica no pós-operatório imediato e a cada 10 dias até a oitava semana, quando os animais foram eutanasiados e suas tíbias retiradas e submetidas ao ensaio mecânico de torção. Na avaliação radiográfica observou-se um percentual maior de tíbias consolidadas, num período inferior a 40 dias no grupo exercitado, enquanto que os valores médios das variáveis mecânicas: torque máximo, deformação angular e energia absorvida até a ruptura, não representaram diferença estatística significativa para p menor e igual a 0,05, apesar de ser observada uma tendência para maiores valores de torque no grupo exercitado. Estes resultados sugerem que o exercício não influencia na velocidade e no padrão de consolidação da fratura neste estudo. / It is known that a load application affects bone healing and in association with exercises, it can reduce bone healing time and fixator permanence time, what would result in several advantages in clinical practice. This article is aimed to evaluate the exercises influence on healing in osteotomised tibiae of rabbits fixed unilateral external fixator. This research was developed in the Bioengineering Laboratory of Medical School of Ribeirão Preto - USP. Sexteen young male New Zealand rabbits were submitted to transverse osteotomy in the middle third of the tibia and fixed with unilateral external fixator. After the surgical procedure, animals were divided into 2 groups: sedentary (n = 10) and exercised (n = 10), being the last group submitted to dayly exercises on a mat for 10 minutes with moderate intensity. A radiographic control was made in the immediate post-operative period and every 10 days during the first 8 weeks. After that, animals were euthanized and their tibia were removed and submitted to a torsional test. For the exercised group, there was observed a larger percentage of healed tibia in a period shorter than 40 days in respect to the radiographic control. The means of mechanical variables (maximum torque, angular displacement and energy required to failure) have shown no significant statisticall difference for p less and equal a 0.05, although it was noticed a tendency to higher values of torque in the exercised group. These results suggest no influence of exercises in relation the speed of and fracture healing in this study.
6

Uso do Método dos Elementos Finitos na avaliação das propriedades mecânicas de um fixador externo / not available

Claudio Cesar Rodrigues Vilarinho 26 September 2000 (has links)
Este trabalho avaliou, utilizando o Método dos Elementos Finitos, o comportamento mecânico em seis ensaios, quatro de flexo compressão com variação apenas no comprimento da haste de fixação, um de flexão ântero-posterior e um de flexão lateral, em um modelo tridimensional de fixador externo construído com auxílio do computador. Para a validação desses ensaios os mesmos testes também foram realizados na máquina universal de ensaio e depois comparados com o método dos elementos finitos. A rigidez no ensaio de flexão lateral obtida no método dos elementos finitos apresentou um valor 106% maior do que o obtido na máquina universal de ensaio, possivelmente por ocorrência de afrouxamento entre as partes adjacentes elo fixador externo no ensaio mecânico, e no ensaio de flexo compressão (número 1) a rigidez obtida pelo método dos elementos finitos foi 7,39% menor elo que a obtida na máquina universal de ensaio. No ensaio número 4 (flexo-compressão) os deslocamentos obtidos, correspondentes a aplicação de uma carga de 15,4 N, utilizando tanto o método dos elementos finitos como a máquina universal ele ensaio, divergiram em 8,5%. Já no ensaio número 5 (flexão ântero-posterior) a divergência foi de 0,9%, para os deslocamentos correspondentes a aplicação de uma carga de 14,4 N. O Métodos dos Elementos Finitos é um eficiente método para prever comportamento mecânico de estruturas complexas. / This work evaluates the mechanical behavior of an external device on a CAD (Computer Aided Design) 3D model in six tests, four of them of flexion-compression with a single variation of the external device stick length, one of longitudinal flexion and one of lateral flexion. They all were carried out applying the Method of the Finite Elements (MFE). For the comparison with the MFE the same mechanical testes were made. The stiffness achieved in the MFE showed a value 106% greater than that of the mechanical test. The test number one of flexion-compression showed a value 7,39% smaller in the MFE than that of the mechanical test. In the test number four (flexion-compression) the corresponding displacement after the application of a 15,4 N working stress showed a difference of 8,5%. The variation of the number five test was of 0,9% for the displacement after the application of a 14,4N working stress. The MEF showed efficient to evaluate the behavior of complex mechanical structures.
7

Simulações computadorizadas de fixadores internos de coluna utilizando o método dos elementos finitos / Computerized internal fixator simulations of column using the method of the finite elements

Antonio Marcos dos Santos 31 March 2004 (has links)
Os problemas freqüentes de patologias ortopédicas e traumáticas da coluna vertebral envolvem a colocação de fixadores internos (parafusos longos, os quais são inseridos nos pedículos posteriores até os corpos vertebrais e conectados por fios nas hastes longitudinais podendo ser fixados em todas as posições pelas porcas). Estes fixadores foram simulados no computador através da construção de modelos geométricos dos mesmos, utilizando o software ANSYS 5.5, que consiste de várias ferramentas para análise do projeto baseado no método dos elementos finitos. Foi também utilizado um software para a modelagem das peças e do conjunto do fixador já existente chamado SOLID EDGE, e logo em seguida o mesmo foi transferido para o software ANSYS 5.5 e simulado. Esta comparação servirá como complemento para possíveis modificações das montagens, dimensões e aplicações, não necessitando de novos ensaios mecânicos na máquina universal de ensaios e sim realizando simulações computadorizadas / The frequent problems of orthopedic and traumatic pathologies of the spinal column that involves the placement of an internal fixator (long screws, which are inserted in the subsequent pedicle until the vertebral and connected by bodies for wires in the longitudinal stems could be fastened in all the positions by the screw). These fixators were simulate in the computer through the construction of geometric models of the same ones, using the software ANSYS 5.5, that consists of several tools for analysis of the project based on the method of the finite elements. It was also used a software for the modelling of the pieces and of the group of the fixador already called existent SOLID EDGE, and then the same was transferred to the software ANSYS 5.5 and simulated. This comparison will serve a complement for possible modifications of the assemblies, dimensions and applications, not needing new mechanical test in the universal machine test but accomplishing computerized simulations
8

Avaliação radiográfica, histomorfométrica e de função de vôo após fixação de osteotomias distais de úmero em pombas (Columba livia), com modelo inédito de fixador externo articulado. Estudo comparativo de fixador transarticular dinâmico e estático / Radiographic histomorphometric and of flight function evaluations after distal humeral osteotomies in pigeons (Columba livia), with inedit articulated external fixator. Comparative study of dynamic and static transarticular fixators

Ferraz, Vanessa Couto de Magalhães 26 September 2008 (has links)
O tratamento de fraturas umerais distais em aves impõe grande dificuldade, devido a córtices muito finas dos ossos A artrodese com fixador externo da articulação úmero-rádio-ulnar é inviável para aves que se pretende reintroduzir ao meio ambiente. Doze animais foram divididos em dois grupos: cirurgias bilaterais com anquilose de uma asa (asa estática) e manutenção da articulação da outra (asa dinâmica) (grupo 1), e cirurgia unilateral, com manutenção da função da articulação (asa dinâmica), sendo a outra controle (asa intacta) (grupo 2). Foram feitas avaliações clínicas, radiológicas, morfológicas do osso, histomorfométricas (de ambos os grupos) e de capacidade de vôo (grupo 2). A 6 semanas, todos os animais apresentavam fraturas consolidadas, com excessão de dois animais do grupo 1, que somente apresentaram consolidação das asas dinâmicas às 9 semanas e das estáticas às 12 semanas. Todos os animais do grupo 2 apresentaram capacidade de vôo adequada, antes de 13 semanas após a cirurgia. No grupo 1 o úmero da asa dinâmica representava 99,1% do comprimento do da asa estática, e no grupo 2, estes eram 99,5% em relação à asa intacta. A amplitude da asa, no grupo 2, demonstrou que a relação da asa dinâmica/intacta foi de 93%, e no grupo 1 a relação asa dinâmica/estática foi de 105%. O volume do osso intacto foi de aproximadamente 29% da área estudada, enquanto o da asa estática foi de 19% e das asas dinâmicas, de 22%. Houve diferença entre o número de osteoblástos das asas intactas e dinâmicas, porém não houve diferença entre as asas estáticas e intactas e entre as dinâmicas e as estáticas, e também não houve diferença do número de osteoclástos entre nenhum tipo de asa. A razão da superfície óssea pelo volume ósseo indica a quantidade de áreas de reabsorção. Não houve diferença entre as asas estática e dinâmica, porém houve diferença entre estas e os controles. O método proposto de técnica para fixação de fraturas umerais distais, sem a anquilose da articulação úmero-rádio-ulnar, demonstrou ser efetivo em manter o comprimento ósseo, a amplitude da asa e assim, garantindo a capacidade de vôo das aves tratadas, além de demonstrar ser equivalente histológicamente à técnica tradicional e mais estável de anquilose da articulação, para este tipo de fratura, e até mesmo, no período estudado, ser equivalente ao osso são, sendo um método adequado para a reparação de fraturas distais de úmero em aves quando se pretende a reabilitação destes animais. / The treatment of humeral distal fractures in birds is very difficult, because these bones are very brittle. Ankylosis of the humeral-radio-ulnar joint with an external fixator is unviable for birds intended for re-habilitation and reintroduction. Twelve animals were used and they were divided in two groups: bilateral surgeries, with ankylosis of one wing (static wing) and maintenance of the joint function of the other wing (dynamic wing) (group 1), and unilateral surgery, with maintenance of the joint function of the wing (dynamic wing), and the other was used as control group (intact wing) (group 2). Clinical, radiographic, morphologic and histomorphometric evaluations of the wings and bones (of both groups) and of evaluations of flight capacity (in group 2) were made. At 6 weeks, all animals had healed fractures, except two animals in group 1, that only presented consolidation of the dynamic wing at 9 weeks and the static wings at 12 weeks. All animals in group 2 were capable of flying before 13 weeks after surgery. In group 1, the humerus of the dynamic wing was 99.1% the length of that of the static wing, and in group 2, these were 99.5% compared to the intact wing. Wing amplitude, in group 2, showed a dynamic/ intact ratio of 93%, and in group 1 the dynamic/ static wing ratio was 105%. The volume of the intact bone was approximately 29% of the studied area, while in the static wing it was of 19% and in the dynamic wing, 22%. There was a difference in the number of osteoblasts of the intact and dynamic wings, but there was no difference between static and intact, and between dynamic and static wings, and also, there was no difference in the numbers of osteoclasts between any wings. The bone surface/ volume ratio indicates the amount of resorption areas. There was no significant difference between static and dynamic wings, but there was a difference between static and intact wings. The proposed method of distal humeral fracture fixation technique, without ankylosis of the humerus-radius-ulna joint, demonstrated being effective in keeping bone length, wing amplitude e therefore, guaranteeing flight capacity of the birds treated, as well as being histologically equivalent to the tradicional, more stable, joint ankylosis technique, for thise kind of fracture, and even, for the studied period, being equivalent to healthy bone, being an adequate method for fracture repair for this kind of fracture in birds, when one intends rehabilitation of these animals.
9

Avaliação mecânica e de composição de liga metálica de dois tamanhos de anéis para fixador externo circular de três diferentes fabricantes para cães / Evaluation of mechanical and metal alloy composition of two sizes of circular external fixator rings for three different manufacturers for dogs

Santos, Jaqueline França dos 14 December 2012 (has links)
Vários implantes cirúrgicos têm sido desenvolvidos para estabilizar fraturas em seres humanos e animais. O fixador esquelético externo circular de Ilizarov é método de fixação amplamente utilizado para tratamento de fraturas complexas, desvios angulares, bem como no alongamento ósseo. O anel destaca-se como componente fundamental desse dispositivo e as cargas de compressão no mesmo plano do anel são devidas principalmente a fios ligados de um lado ao outro do implante. O estudo teve como objetivo comparar a resistência à compressão axial de anéis de Ilizarov e analisar a composição da liga metálica desses anéis. Foram testados dois diâmetros de anéis de três fabricantes nacionais para os ensaios biomecânicos de compressão axial, divididos em dois grupos com quinze corpos de prova. Os testes foram realizados em máquina universal de ensaios Kratos® modelo KE 3.000MP, dotada de célula de carga de 3000N com velocidade de ensaio de 10 milímetros por minuto. Os parâmetros força e deformação foram enviados ao computador IBM®-PC através do sistema de aquisição analógica Lynx® modelo ADS-2000, que permitiu a gravação dos parâmetros para posterior análise. Também avaliou-se a composição elementar dos anéis através do método TTPIXE (partículas induzidas pela emissão de raios X em alvos espessos) em PIXE externo. Os espectros foram acumulados em buffer-multicanal conectado a um micro-computador pessoal tipo IBM-PC®. A redução de espectros de raios-X foi realizada por meio do programa AXIL. Concluiu-se que os anéis para fixador esquelético externo circular são compostos de liga metálica de alumínio e que existe diferença entre os fabricantes nacionais no ensaio mecânico de compressão axial, sendo que o fabricante A é mais rígido que os outros fabricantes para os dois diâmetros (60 e 80 milímetros) de anel e mais resistente que os outros fabricantes para o anel de 80 milímetros. / Various surgical implants have been developed to stabilize fractures in humans and animals. Ilizarov\'s circular external skeletal fixator is a fixation method widely used for the treatment of complex fractures, angular deviation, as well as in bone lengthening. The ring stands out as a fundamental component of the device and compression loads in the same plane of the ring are due mainly to wires connected from one side to another of the implant. The study aimed to compare the resistance to axial compression on Ilizarovs rings and analyze the alloy composition of these rings. Two diameters were tested of three domestic ring manufacturers for biomechanical axial compression, divided into two groups with fifteen specimens each group. The tests were performed in a universal test machine Kratos® model 3.000MP KE, equipped with a 3000N load cell with a test speed of 10 mm per minute. The strength and deformation parameters were sent to the IBM®-PC computer through the Lynx® analog acquisition system model ADS-2000, which allowed the recording of the parameters for further analysis. Also, the rings alloy composition was evaluated using the TTPIXE method (thick-target particle induced X-ray emission) in external PIXE. The spectra were accumulated in a multi-channel buffer connected to an IBM®-PC type personal microcomputer. The reduction of X-ray spectra was performed using the AXIL program. In conclusion the rings was made from aluminum alloy, witch differs in composition among different fabricants, also the rings showed differences performance in mechanical testing of axial compression, and the manufacturer A is more rigid than the other manufacturers for the two diameters (60 and 80 mm) ring and tougher than the other manufacturers to the 80 mm ring.
10

Avaliação mecânica e de composição de liga metálica de dois tamanhos de anéis para fixador externo circular de três diferentes fabricantes para cães / Evaluation of mechanical and metal alloy composition of two sizes of circular external fixator rings for three different manufacturers for dogs

Jaqueline França dos Santos 14 December 2012 (has links)
Vários implantes cirúrgicos têm sido desenvolvidos para estabilizar fraturas em seres humanos e animais. O fixador esquelético externo circular de Ilizarov é método de fixação amplamente utilizado para tratamento de fraturas complexas, desvios angulares, bem como no alongamento ósseo. O anel destaca-se como componente fundamental desse dispositivo e as cargas de compressão no mesmo plano do anel são devidas principalmente a fios ligados de um lado ao outro do implante. O estudo teve como objetivo comparar a resistência à compressão axial de anéis de Ilizarov e analisar a composição da liga metálica desses anéis. Foram testados dois diâmetros de anéis de três fabricantes nacionais para os ensaios biomecânicos de compressão axial, divididos em dois grupos com quinze corpos de prova. Os testes foram realizados em máquina universal de ensaios Kratos® modelo KE 3.000MP, dotada de célula de carga de 3000N com velocidade de ensaio de 10 milímetros por minuto. Os parâmetros força e deformação foram enviados ao computador IBM®-PC através do sistema de aquisição analógica Lynx® modelo ADS-2000, que permitiu a gravação dos parâmetros para posterior análise. Também avaliou-se a composição elementar dos anéis através do método TTPIXE (partículas induzidas pela emissão de raios X em alvos espessos) em PIXE externo. Os espectros foram acumulados em buffer-multicanal conectado a um micro-computador pessoal tipo IBM-PC®. A redução de espectros de raios-X foi realizada por meio do programa AXIL. Concluiu-se que os anéis para fixador esquelético externo circular são compostos de liga metálica de alumínio e que existe diferença entre os fabricantes nacionais no ensaio mecânico de compressão axial, sendo que o fabricante A é mais rígido que os outros fabricantes para os dois diâmetros (60 e 80 milímetros) de anel e mais resistente que os outros fabricantes para o anel de 80 milímetros. / Various surgical implants have been developed to stabilize fractures in humans and animals. Ilizarov\'s circular external skeletal fixator is a fixation method widely used for the treatment of complex fractures, angular deviation, as well as in bone lengthening. The ring stands out as a fundamental component of the device and compression loads in the same plane of the ring are due mainly to wires connected from one side to another of the implant. The study aimed to compare the resistance to axial compression on Ilizarovs rings and analyze the alloy composition of these rings. Two diameters were tested of three domestic ring manufacturers for biomechanical axial compression, divided into two groups with fifteen specimens each group. The tests were performed in a universal test machine Kratos® model 3.000MP KE, equipped with a 3000N load cell with a test speed of 10 mm per minute. The strength and deformation parameters were sent to the IBM®-PC computer through the Lynx® analog acquisition system model ADS-2000, which allowed the recording of the parameters for further analysis. Also, the rings alloy composition was evaluated using the TTPIXE method (thick-target particle induced X-ray emission) in external PIXE. The spectra were accumulated in a multi-channel buffer connected to an IBM®-PC type personal microcomputer. The reduction of X-ray spectra was performed using the AXIL program. In conclusion the rings was made from aluminum alloy, witch differs in composition among different fabricants, also the rings showed differences performance in mechanical testing of axial compression, and the manufacturer A is more rigid than the other manufacturers for the two diameters (60 and 80 mm) ring and tougher than the other manufacturers to the 80 mm ring.

Page generated in 0.0332 seconds