Modelación térmica del suelo alrededor de tubos enterrados en sistemas de colección de energía geotérmica de baja entalpía

Zenteno Arenas, Alonso Gonzalo January 2013 (has links)
Ingeniero Civil Mecánico / Los sistemas de climatización con energía geotérmica, aprovechan la estabilidad de temperatura que tiene el subsuelo para extraer calor de la vivienda y transferirlo al suelo, o de forma inversa, extraer calor del suelo y transferirlo a la vivienda (depende si se trata de invierno o verano). Para realizar esto se usan tubos enterrados en que se hace circular un fluido interiormente para transportar el calor. En la literatura se proponen métodos incompletos para calcular la capacidad de transferencia entre los tubos enterrados y el suelo, ya que no se considera la modificación de temperatura del suelo alrededor de los tubos enterrados. En este trabajo, usando simulaciones numéricas, se resuelve el campo de temperaturas alrededor de los tubos en función del tiempo y se determina la resistencia térmica del suelo. Usando los resultados de estas simulaciones, se propone una fórmula (en función de las variables relevantes) para estimar de forma sencilla el promedio de capacidad de transferencia que tendrá un tubo. Se realizan simulaciones con 2 y 3 tubos paralelos, para evaluar la disminución de la capacidad de transferir calor debido a la interferencia térmica que se produce entre tubos cercanos. Estos resultados muestran que el espaciado, es un factor importante a la hora de diseñar un circuito de tubos enterrados, ya que con arreglos muy compactos se disminuye en más un 50% la capacidad de captar calor. Con los resultados de las simulaciones se evalúan cuatro casos, para determinar cuán importante es agregar la resistencia térmica del suelo, a las conocidas y bien estudiadas resistencias térmicas de la pared del tubo y del fluido interno. De forma general, el suelo restringe el flujo de calor (más que la pared y el fluido interno) y se vuelve el elemento clave para determinar la capacidad de transferencia. Cuantificar este fenómeno, permite diseñar sistemas de colección, tomando en cuenta la resistencia térmica del suelo y determinar correctamente la capacidad de transferir calor. Así, se puede generar una solución acorde a la demanda térmica requerida.
2

Producción de calor radiogénico y flujo de calor en las rocas del basamento de la cuenca de Talca

Morales Molina, Cristián Andrés January 2014 (has links)
Geólogo / En este trabajo se presenta una estimación del ujo de calor HF (por sus siglas en inglés Heat Flow) para la cuenca de Talca (35° 25' 59'' S, 71° 40' 0'' W) , a partir de la medición de la producción de calor radiogénico RHP (por sus siglas en inglés Radiogenic Heat Production) de las rocas perteneciente a la corteza superior, esencialmente a oramientos mesozoicos y cenozoicos. Considera por parte de la literatura, el RHP del resto de la corteza y el manto litosférico, así como el flujo de calor derivado por la diferencia de temperatura entre la base de la litósfera y la super cie. Se estimó el RHP de las rocas de la corteza superior en base a la concentración de U, Th y K en ellas mediante un espectrómetro/escintilómetro portátil de rayos gamma, los datos para el resto de la litósfera y las propiedades físicas de las rocas fueron obtenidas de la literatura. Para la estimación del HF se utilizo modelación de elementos nitos sobre un per l estructural de la cuenca, en el cual se incluyen las propiedades físicas, RHP y temperaturas bordes de la litósfera. El programa utilizado para la modelación fue el software COMSOL Multiphysics (versión 4.3a). El RHP de las formaciones de la corteza superior varía desde 0,4 µ W/m^3 a 2,8 µW/m^3, teniendo como media una producción de calor radiogénico de 1,3 µ W/m^3 . El HF estimado por el modelo para la cuenca de Talca es de entre 62-65 mW/m^2 de los cuales 15 mW/m^2 son producidos en la corteza superior siendo un 23% del fl ujo de calor que llega a la super cie. El gradiente térmico estimado bajo Talca corresponde a 23 °C/km.
3

Contribución de la conductividad térmica y la producción de calor radiogénico a la estructura termal de la corteza superior en la latitud de Santiago, Chile

Valdenegro Cid, Pablo Esteban January 2015 (has links)
Geólogo / Contribución de la conductividad térmica y la producción de calor radiogénico a la estructura termal de la corteza superior en la latitud de Santiago, Chile La conductividad térmica y la producción de calor radiogénico (RHP, por sus siglas del inglés Radiogenic Heat Production), son dos propiedades termales intrínsecas a un volumen de roca. Estas propiedades influyen directamente en la estructura termal de la corteza, pues determinan la conducción de calor y, a la vez, lo producen. La conductividad térmica y RHP dependen de la composición química de las rocas y de sus características petrográficas. Además, las variaciones de presión y temperatura relacionadas a la profundidad, afectan las propiedades termales, principalmente por el aumento de la temperatura. El estudio y modelamiento de la estructura termal de la litósfera representan un gran desafío, considerando la resolución numérica del problema y las condiciones iniciales y de borde. Se entregan aquí los valores obtenidos para la conductividad térmica y RHP, correspondientes a las propiedades termales más influyentes en la estructura termal de la corteza superior. Las rocas de la corteza superior en la latitud de Santiago están compuestas por unidades de la Cordillera de la Costa, que corresponden a rocas estratificadas de origen volcánico y sedimentario del Jurásico y Cretácico, además de rocas intrusivas paleozoicas, jurásicas y cretácicas, y por unidades de la Cordillera Principal de Los Andes, correspondientes a rocas estratificadas de origen volcánico del Oligoceno al Mioceno e intrusivos de la misma edad. El objetivo principal de este trabajo es investigar las propiedades termales de las unidades geológicas de la corteza superior en la latitud de Santiago, y su relación con la litología y edad. Esto se llevó a cabo realizando nuevas mediciones de las propiedades termales y ajustando los datos a distribuciones estadísticas, con un alto nivel de confiabilidad. La conductividad térmica se midió utilizando una sonda mediante el método de fuente de calor lineal, mientras que el cálculo de RHP se realizó a partir de las concentraciones medidas de U, Th y K, (RHPe, del inglés Radiogenic Heat Production elements). Para la conductividad térmica, el mayor valor promedio se registró en la Formación Lo Prado, cuya magnitud es 2,91[W/m*K], mientras que el mínimo se obtuvo en la Formación del Cordón Los Ratones, con 1,60 [W/m*K]. El máximo medido se registró en la Formación Lo Prado, con un valor de 4,92 [W/m*K]. Por otra parte, para la producción de calor radiogénico, el valor promedio más alto se obtuvo en la Formación Veta Negra, con 1,6 [𝜇W/m3], mientras que el mínimo se obtuvo para la Formación Lo Valle, con un valor de 0,59 [𝜇W/m3].El valor máximo medido se registró en la Formación Lo Prado, con una magnitud de 3,48 [𝜇W/m3]. Conductividad térmica y RHP dependen principalmente de la litología de las formaciones, siendo otros factores como edad, tamaño de grano, etc., menos o totalmente no influyentes. La estimación de flujo calórico para la zona de estudio está entre 45 a 60 [mW/m2], y el potencial de la cuenca de Santiago se asocia a la geotermia de muy baja entalpía.
4

Producción de calor radiogénico y flujo calórico en la cuenca de Santiago, Región Metropolitana, Chile

Poblete Anderson, Nicolás Andrés January 2014 (has links)
Geólogo / El objetivo de este trabajo fue estimar la influencia de la producción de calor radiogénico (RHP por sus siglas del inglés Radiogenic Heat Production), en el flujo calórico total que llega a la base del relleno sedimentario de la cuenca de Santiago. La cuenca de Santiago corresponde a una depresión irregular, ubicada entre los 33-33.9°S y 70.5-71°W. Sus límites son: hacia el norte el cordón de cerros de los Altos de Polpaico y los Cerros de Colina, hacia al oeste la Cordillera de la Costa, hacia el este la Cordillera de Los Andes y hacia el sur la Angostura de Paine. La RHP se estimó en base a la concentración de elementos productores de calor radiogénico (RHPe: U, Th y K; por sus siglas del inglés Radiogenic Heat Production elements), de las diferentes litologías que componen el basamento de la cuenca de Santiago. Los RHPe, fueron medidos en numerosos afloramientos de rocas mesozoicas y cenozoicas, que rodean a la cuenca de Santiago, con lo que se logró determinar la concentración de RHPe en las litologías que componen la corteza superior. Las concentraciones de RHPe de las capas inferiores de la corteza y manto litosférico fueron obtenidas de la literatura. Las RHP promedio que componen la corteza superior, variaron entre 0,33 y 2,17 uW/m3, con un promedio de 1,3 uW/m3. Los componentes que se necesitaron para estimar el flujo calórico fueron: estructura de la litósfera, propiedades físicas y termales de las unidades que la componen, entre ellas la RHP. La estimación del flujo calórico se realizó en base a una modelación de transferencia de calor en sólidos, ocupando elementos finitos, en el software COMSOL Multiphysics (versión 4.3). El flujo calórico que llega a la base del relleno sedimentario de la cuenca de Santiago fue estimado en 61-67 mW/m2. El aporte de la RHP de toda la litósfera, en el flujo calórico que llega la superficie, estuvo entre 28,5 a 30 mW/m2, constituyendo un 45-48% del total, mientras que aporte del RHP de la corteza superior fue 12 mW/m2, constituyendo un 18% del flujo calórico total que alcanza la superficie. El relieve afectó de la siguiente manera al flujo calórico: en altos topográficos, porque el calor se distribuye en un área mayor, se produce una disminución del flujo calórico que llega a la superficie, en cambio en bajos topográficos sucede todo lo contrario, es decir, disminuye el área y aumenta el flujo calórico que llega a la superficie. Finalmente, el gradiente geotermal, en las rocas cercanas a la superficie de Santiago, fue estimado en 24°C/km. Esto implica que las temperaturas necesarias para algún uso geotérmico de muy baja entalpía se encontraron alrededor de los 200 m de profundidad; y para uso de geotermia de alta entalpía, la profundidad requerida es alrededor de 6 km.
5

Estudio de las características físicas y geométricas de la llama en los incendios forestales

Zárate López, Luís Guadalupe 22 April 2004 (has links)
La tesis doctoral propone como objeto de estudio las llamas de un incendio forestal (forma, tamaño, intensidad de radiación, temperatura, etc.). Mediante su modelización matemática se propone la aplicación de un problema práctico (zonas de seguridad). Para ello se basa en la experiencia previa con incendios de balsas de hidrocarburos de gran tamaño y a la relativa similitud en el comportamiento de las llamas de incendios de hidrocarburos y de incendios forestales. Se han analizado diversos modelos de radiación térmica y de vulnerabilidad. Como parte de dicho análisis se han estudiado las diversas ecuaciones existentes para el cálculo del factor de vista correspondiente a distintas situaciones, relativas básicamente a frente de llama plano y diversas posiciones de la superficie irradiada; también se ha analizado el caso de cuerpo irradiante cilíndrico, de utilidad para estudiar la radiación desde el propio incendio a una parte del combustible. El estudio comparativo efectuado ha permitido seleccionar las ecuaciones más adecuadas para el cálculo del factor de vista para las disposiciones geométricas llama/objetivo más frecuentes y características; las ecuaciones seleccionadas han sido las de McGuire, cuyo carácter analítico garantiza una mayor exactitud que en el caso de las metodologías numéricas.La utilización del conjunto de modelos y ecuaciones seleccionados, junto con la aplicación de los valores de vulnerabilidad, ha permitido el establecimiento -para unas condiciones meteorológicas rigurosas y para las trece tipologías de combustible de Rothermel- de distancias de seguridad. Estos valores pueden aplicarse en el establecimiento de zonas de seguridad, vías de acceso y escape, etc., pudiendo ser de gran utilidad tanto en la planificación de tipo preventivo como en las actuaciones en emergencias / This doctoral thesis is focussed on the study of the forest fire flames (shape, size, radiation intensity, temperature, etc.). A proposal of a practical application (security zones) is carried out by the mathematical modelling of the flames. In order to attain such a goal, the previous experience in hydrocarbon pool fires of big size and the relative similarity between the behaviour of the hydrocarbon and forest fire flames have been very useful.Several thermal radiation and vulnerability models have been analysed. One of the main parts of such analysis has been the study of diverse existing equations for the calculation of the view factor corresponding to a different situations basically related to the plane flame front and to the diverse positions of the irradiated surface; moreover, the case of the irradiating cylindrical shape has been analysed, being very useful in order to study the radiation from the very fire to a part of the fuel. The comparative study carried out has allowed to choose the proper equations for the view factor calculation and also for the most common geometrical and characteristic flame/target dispositions; the McGuire equations have been selected, whose analytic character guarantees higher accuracy than the ones used in numerical methodologies.The use of the set of the selected models and equations together with the application of the vulnerability values have allowed the establishment -for strict meteorological conditions and for the thirteen Rothermel fuel categories- of safety distances. These values can be used to establish safety zones, access and escape routes, etc, and can be very useful not only in the preventive planning but also in the emergency response.
6

Experimental study of the behavior of gasoline direct injection GDI sprays during wall impingement under realistic engine conditions.

Carvallo García, César Leonardo 17 July 2023 (has links)
[ES] A medida que aumenta la conciencia climática y se buscan reducir las emisiones globales, se están realizando esfuerzos para producir tecnologías que permitan desarrollar motores más limpios y amigables con el medio ambiente. Los sistemas GDI (inyección directa de gasolina) tienen el potencial de cumplir con los cada vez más estrictos estándares de emisiones y, al mismo tiempo, mejorar el consumo de combustible. El espacio limitado dentro de la cámara de combustión hace que el impacto del chorro con la pared sea un fenómeno común en los motores de inyección directa de gasolina. Este fenómeno tiene un efecto significativo en el desarrollo del chorro y su interacción con el aire en la cámara. En condiciones de arranque en frío, las bajas presiones y temperaturas en la cámara facilitan la deposición del combustible en la superficie del pistón, lo que conduce a un aumento considerable en la formación de hollín y en los hidrocarburos sin quemar. Esta tesis busca proporcionar información sobre las características más relevantes de la interacción chorro-pared en sistemas de inyección directa de gasolina en condiciones de arranque en frío y otras condiciones evaporativas. Para ello, se utilizó una pared plana ubicada a diferentes distancias de impacto y ángulos con respecto a la punta del inyector. Se empleó un inyector solenoide fabricado por Continental y el inyector "Spray G", utilizando iso-octano como combustible inyectado. El estudio se llevó a cabo en diversas instalaciones experimentales cubriendo varias técnicas ópticas. El estudio de la interacción chorro-pared se llevó a cabo utilizando tres campañas experimentales. En la primera, se utilizó una pared de cuarzo transparente para analizar las características macroscópicas del chorro al impactar la pared, observándola lateral y frontalmente con el uso de tres cámaras de alta velocidad gracias a los accesos ópticos de la instalación experimental. En la segunda, se empleó una pared termorregulada de acero inoxidable para medir el efecto que tienen las condiciones de operación y ambientales sobre la transferencia de calor entre la pared y el chorro durante el evento de inyección de combustible. Se observó que la penetración del chorro libre y el desarrollo del chorro sobre la pared son influenciados por la presión de inyección y el ángulo de inclinación de la pared. El ancho del chorro medido después del impacto fue afectado principalmente por la distancia entre el inyector y la pared y por el ángulo de la pared pero más aún por la distancia respecto al punto de impacto sobre la cual fue medida. La semi área de impacto es susceptible a cambios en el ángulo de la pared y la distancia inyector-pared teniendo un papel fundamental en el arrastre de aire entre el chorro y el ambiente. No se encontraron diferencias significativas entre las fases líquida y vapor tanto para la penetración de chorro libre como para el desarrollo del chorro sobre la pared a temperatura ambiente. Por el contrario, con la pared calentada, se obtuvieron diferencias entre la fase líquida y vapor, destacando la contribución de la evaporación de combustible causada por el incremento en la temperatura de la pared. Respecto a la pared instrumentada, tanto la temperatura del combustible como de la pared produjeron los picos más significativos en términos del flujo de calor superficial. Órdenes de magnitud similares respecto al flujo de calor superficial fueron encontrados entre las campañas experimentales de la pared instrumentada y la termografía infrarroja. La aparición del flash boiling en condiciones de menor contrapresión ambiental y mayor temperatura del combustible modificó la morfología del chorro en términos de anchura , lo que tuvo repercusiones significativas en el parámetro R (que depende de la penetración del chorro) y en el número de gotas de líquido presentes en el chorro, afectando tanto a los perfiles de extinción de la luz como a los perfiles del flujo de calor superficial. / [CA] A mesura que augmenta la consciència climàtica i es busquen reduir les emissions globals, s'estan fent esforços per a produir tecnologies que permeten desenvolupar motors més nets i amigables amb el medi ambient. Els sistemes GDI (injecció directa de gasolina) tenen el potencial de complir amb els estrictes estàndards d'emissions i, al mateix temps, millorar el consum de combustible. L'espai limitat dins de la cambra de combustió fa que l'impacte del doll amb la paret siga un fenomen comú en els motors d'injecció directa de gasolina. Aquest fenomen té un efecte significatiu en el desenvolupament del doll i la seua interacció amb l'aire en la cambra. La interacció doll-paret és un fenomen interessant i difícil de comprendre que ocorre durant el procés de combustió. En condicions d'arrancada en fred, les baixes pressions i temperatures en la cambra faciliten la deposició del combustible en la superfície del pistó, la qual cosa condueix a un augment considerable en la formació de sutge i en els hidrocarburs sense cremar. Aquesta tesi busca proporcionar informació sobre les característiques més rellevants de la interacció doll-paret en sistemes d'injecció directa de gasolina en condicions d'arrancada en fred i altres condicions evaporatives. Per a això, es va utilitzar una paret plana situada a diferents distàncies d'impacte i angles respecte a la punta de l'injector. Es va emprar un injector solenoide fabricat per Continental i l'injector "Spray G", utilitzant iso-octà com a combustible injectat. L'estudi es va dur a terme en diverses instal·lacions experimentals cobrint diverses tècniques òptiques. L'estudi de la interacció doll-paret es va dur a terme utilitzant tres campanyes experimentals. En la primera, es va utilitzar una paret de quars transparent per a analitzar les característiques macroscòpiques del doll en impactar la paret, observant-la lateral i frontalment amb l'ús de tres càmeres d'alta velocitat gràcies als accessos òptics de la instal·lació experimental. En la segona, es va emprar una paret termorregulada d'acer inoxidable per a mesurar l'efecte que tenen les condicions d'operació i ambientals sobre la transferència de calor entre la paret i el doll durant l'esdeveniment d'injecció de combustible. Es va observar que la penetració del doll lliure i el desenvolupament del doll sobre la paret són influenciats per la pressió d'injecció i l'angle d'inclinació de la paret. L'ample del doll mesurat després de l'impacte va ser afectat principalment per la distància entre l'injector i la paret i per l'angle de la paret però més encara per la distància respecte al punt d'impacte sobre la qual va ser mesurada. La semi àrea d'impacte és susceptible a canvis en l'angle de la paret i la distancia injector-paret tenint un paper fonamental en l'arrossegament d'aire entre el doll i l'ambient. No es van trobar diferències significatives entre les fases líquida i vapor tant per a la penetració de doll lliure com per al desenvolupament del doll sobre la paret a temperatura ambient. Per contra, amb la paret calfada, es van obtindre diferències entre la fase líquida i vapor, destacant la contribució de l'evaporació de combustible causada per l'increment en la temperatura de la paret. Respecte a la paret instrumentada, tant la temperatura del combustible com de la paret van produir els pics més significatius en termes del flux de calor superficial. Ordres de magnitud similars respecte al flux de calor superficial van ser trobats entre les campanyes experimentals de la paret instrumentada i la termografia infraroja. L'aparició del flaix boiling en condicions de menor contrapressió ambiental i major temperatura del combustible va modificar la morfologia del doll en termes d'amplària, la qual cosa va tindre repercussions significatives en el paràmetre R i en el nombre de gotes de líquid presents en el doll, afectant tant els perfils d'extinció de la llum com als perfils del flux de calor superfial. / [EN] Fuel injection is one of the most important factor that must be considered to achieve cleaner and more efficient internal combustion engines. Its role is more evident when direct injection strategies are used. As awareness of climate change and global emission reduction policies increase, efforts are being made to develop new technologies that enable cleaner and more environmentally friendly engines. The gasoline direct injection systems can fulfill strict emission standards and improve fuel consumption. Because of the space constraints inside the combustion chamber for spray penetration, collision and interaction with the wall are common events in direct injection engines, considerably influencing spray formation and air-spray interaction inside the chamber. In cold-start engine conditions, the lower injection pressures and temperatures in the combustion chamber enhance the fuel deposition over the piston surface, incrementing the soot and the unburned hydrocarbon formation. The present work highlights the fundamental aspects of the spray-wall interaction for the gasoline direct injection (GDI) system under cold-start and other evaporative conditions. For that, a flat wall is located several distances and at different wall angles to the injector tip. Also, this thesis involves using a solenoid injector produced by Continental and the well-known "Spray G" injector using iso-octane as injected fuel covering several techniques and experimental facilities. To analyze the spray-wall interaction, three experimental approaches were used: The first used three high-speed cameras and a quartz wall inside the test rig vessel to study the macroscopic characteristics of the spray, which was observed lateral and frontal by using the optical accesses of the vessel. The second approach used a stainless steel wall to catch the effect of the operating and ambient conditions over the heat flux between the wall and the spray during the fuel injection event and determine how the spray development is affected by the cold-start realistic engine conditions and other evaporative conditions that were included in the test matrix. This wall was coupled with sensors to control the initial surface temperature and to compute the temperature variation in time and the surface heat flux using high-speed thermocouples. The spray under free-jet conditions was also analyzed as a comparison point with the spray-wall interaction conditions. The free spray penetration and the spray spreading over the wall were influenced mainly by the injection pressure and the wall angle. The spray thickness measured after the SWI was affected primarily by the wall-to-tip distance and the wall angle but even more by the distance from the impact point in which it is measured. The semi-circle impact area was susceptible to wall angles and wall-to-tip distance variations, essential in the spray-air entrainment. No remarkable differences were found between the liquid and vapor phases for the free jet or the isothermal wall configuration. In contrast, some differences were obtained for the instrumented and thermoregulated wall, remarking the contribution of fuel evaporation caused by the wall temperature increase. Regarding the thermoregulated wall, the fuel and wall temperatures produced the most important peaks in terms of surface heat flux. A similar order of magnitude regarding the surface heat flux was found between the thermoregulated wall and infrared thermography experimental campaigns. The flash boiling appearance for the lower ambient back pressure and higher fuel temperature condition changed the spray morphology in terms of the width (spray angle), having significant repercussions over the R-parameter (which depends on the spray penetration) and in the number of liquid droplets present in the spray affecting both the light extinction profiles and the surface heat flux profiles. / Esta tesis se ha desarrollado en el marco de una ayuda para la Formación de Personal Investigador (FPI) Subprograma 1 (PAID-01-19) financiada por la Universitat Politècnica de València. / Carvallo García, CL. (2023). Experimental study of the behavior of gasoline direct injection GDI sprays during wall impingement under realistic engine conditions [Tesis doctoral]. Universitat Politècnica de València. https://doi.org/10.4995/Thesis/10251/195027