• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 58
  • 3
  • 2
  • Tagged with
  • 65
  • 21
  • 18
  • 11
  • 10
  • 10
  • 9
  • 9
  • 9
  • 9
  • 9
  • 9
  • 9
  • 8
  • 8
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Construção, caracterização e estabilização de um pente de frequências ópticas

PALACIOS ROQUE, Guillermo Francisco 24 July 2017 (has links)
Submitted by Pedro Barros (pedro.silvabarros@ufpe.br) on 2018-08-29T19:19:29Z No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) DISSERTAÇÃO Guillermo Francisco Palacios.pdf: 3683604 bytes, checksum: b8298a5c80e4c63eb0c757d3c6b68fb9 (MD5) / Approved for entry into archive by Alice Araujo (alice.caraujo@ufpe.br) on 2018-09-10T22:23:44Z (GMT) No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) DISSERTAÇÃO Guillermo Francisco Palacios.pdf: 3683604 bytes, checksum: b8298a5c80e4c63eb0c757d3c6b68fb9 (MD5) / Made available in DSpace on 2018-09-10T22:23:44Z (GMT). No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) DISSERTAÇÃO Guillermo Francisco Palacios.pdf: 3683604 bytes, checksum: b8298a5c80e4c63eb0c757d3c6b68fb9 (MD5) Previous issue date: 2017-07-24 / CAPES / Neste trabalho, construímos um pente de frequências ópticas usando, como meio de ganho, um cristal de titânio safira (Ti:S) em uma cavidade com geometria em anel, no qual caracterizamos a estabilidade da taxa de repetição. No regime de modos travados, o laser opera em 815 nm com uma largura de banda de aproximadamente 29 nm e uma taxa de repetição de 830 MHz. Com a estabilização eletrônica, baseada num esquema de Phase Lock Loop, conseguimos uma estabilidade do desvio de fracionário da frequência de repetição de 10⁻¹¹ para tempos de até 1 s e 10⁻¹² para tempos de até 500 s. Também foi construído um interferômetro f-2f onde medimos a frequência de offset, com o objetivo de sua posterior estabilização. As medições desta última mostraram um valor de 73 MHz. Isso encerra a primeira etapa de um trabalho mais extenso, que contempla a completa estabilização do laser, com aplicações em espectroscopia atômica. / In this work, we constructed an optical frequency comb using as a means of gain, a titanium sapphire crystal (Ti:S) in a cavity with ring geometry, in which we characterized the repetition rate stability. In the mode-locked mode, the laser operates at 815 nm, with a bandwidth of approximately 29 nm and a repetition rate of 830 MHz. With electronic stabilization, based on a Phase Lock Loop scheme, we achieve a stability of the deviation of fractional frequency of repetition rate of 10⁻¹¹ for times of 1 s and 10⁻¹² for times of 500 s. We also mounted an f-2f interferometer where we measured the offset frequency, with the objective of its subsequent stabilization. The measurements of this, showed a value of 73 MHz. This ends the first stage of a more extensive work, which contemplates the complete stabilization of the laser, with applications in atomic spectroscopy.
2

Estudo estrutural e propriedades de transporte de filmes espessos de Hg,Re-1223.

RODRIGUES JUNIOR, V. A. 23 May 2014 (has links)
Made available in DSpace on 2018-08-01T22:30:00Z (GMT). No. of bitstreams: 1 tese_7772_Tese final Valdi Antonio Rodrigues Jr.pdf: 4573743 bytes, checksum: 65d59e55872519311f6f9dd3665f4cfe (MD5) Previous issue date: 2014-05-23 / Nesta tese será descrito o desenvolvimento do supercondutor Hg0.82Re0,18Ba2Ca2Cu3O8+x preparado com o filme espesso do precursor de Ba2Ca2Cu3O5+d depositado no substrato de PrBa2Cu3O7 com a técnica de Ablação a Laser. A incorporação do mercúrio no filme espesso de precursor foi realizada utilizando a técnica do encapsulamento de tubo de quartzo com a atmosfera de mercúrio. Foram feitas medidas de corrente crítica DC abaixo da temperatura crítica do material, determinando a densidade de corrente crítica em função da temperatura. O comportamento geral desta relação confirma que o filme espesso supercondutor (Hg,Re)-1223, assim como o bulk, é uma junção de grãos classificado como supercondutor-isolante-supercondutor (SIS). Após as medidas de corrente crítica, o filme espesso supercondutor não apresentou nenhuma degradação ou perda estequiométrica e sua temperatura crítica não mudou após o teste. Levando-se em conta o valor da corrente crítica do filme espesso e comparando com a amostra em bulk, o que sugere que o desenvolvimento descrito pode ser aplicado para produzir dispositivos eletrônicos como limitadores de corrente e bolômetros baseados no filme da cerâmica supercondutora de (Hg,Re)-1223.
3

Medida da corrente elétrica de frequência híbrida no cérebro de frangos para fins de insensibilização / Measurement of hybrid frequency electric current in brain\'s broilers for stunning purposes

Sato, Denis 26 October 2016 (has links)
Neste estudo foram realizadas as medidas de intensidade da corrente elétrica contínua no cérebro de frangos de corte utilizando ondas de frequências híbridas e comparadas com ondas de frequências únicas. Considerando uma onda quadrada com frequência de 50 Hz, com ciclo de trabalho de 50%, a onda híbrida gera pulsos de 1500 Hz durante a metade de cada ciclo da onda, durante a fase ativa do pulso elétrico. Para cada uma das frequências híbridas utilizadas, o mesmo princípio foi aplicado. Foram utilizados 30 frangos de corte ROSS aos 42 dias de idade, com peso médio de 2,96 kg (std = 0,02), distribuídos aleatoriamente em 6 tratamentos com 5 repetições. Os tratamentos foram: 1) 50 Hz, 100 mA; 2) 200 Hz, 100 mA; 3) 400 Hz, 150 mA; 4) 50 Hz híbrida, 100 mA; 5) 200 Hz híbrida, 100 mA; e 6) 400 Hz híbrida, 150 mA. As formas de onda foram monitoradas através de um osciloscópio portátil. As aves foram abatidas e eletrodos de aço inoxidável, montados em uma base de polietileno, foram então inseridos nos hemisférios direito e esquerdo do cérebro das aves, logo abaixo do osso frontal do crânio, mantendo-se uma distância de 15 mm entre as agulhas. Os fios dos eletrodos foram conectados à um multímetro digital e a corrente elétrica foi registrada em microampères (µA), para cada um dos tratamentos. A corrente elétrica foi aplicada em cada ave individualmente, em banho eletrificado utilizando-se uma cuba experimental de acrílico e respeitando os parâmetros de insensibilização elétrica da Resolução 1099/2009 da União Europeia. A análise da variância detectou efeito significativo de frango, de sistema de frequência e de frequência para a corrente medida no cérebro dos frangos. Não houve efeito significativo da interação e da ordem de aplicação dos tratamentos. O desdobramento da análise mostrou que a onda híbrida apresenta maiores correntes (média = 58,4 ± 4,4 µA) passando pelo cérebro das aves comparado aos resultados obtidos pela onda única (média = 48,2 ± 4,1 µA). Visto que o sistema de onda híbrida apresentou um maior fluxo de corrente elétrica no cérebro de frangos de corte, sugere-se que o sistema de onda híbrida possa apresentar melhores índices de qualidade de carne mantendo o índice de bem-estar animal. Estudos sobre a eficácia da insensibilização por eletroencefalografia e parâmetros de qualidade da carne, utilizando este sistema, são necessários para se confirmar ou rejeitar tais suposições. / In this study, the intensity of the electrical direct current (DC) in the brain of broilers using hybrid-frequency waveforms system compared to single frequencies was measured. Considering a square-wave with frequency of 50 Hz (duty-cycle 50%), the hybrid-frequency waveform is obtained generating pulses at 1500 Hz in half of each cycle, in pulse-width phase. The same principle was used in the others tested hybrid frequencies. A total of 30 broilers ROSS 42 days-old with an average weight of 2.96 kg (std = 0.02), randomly distributed in a design of 6 treatments with 5 repetitions. The treatments were: 1) 50 Hz, 100 mA; 2) 200 Hz, 100 mA; 3) 400 Hz, 150 mA; 4) hybrid 50 Hz, 100 mA; 5) hybrid 200 Hz, 100 mA; and 6) hybrid 400 Hz, 150 mA. The waveforms were monitored with a portable oscilloscope. The birds were slaughtered and stainless steel electrodes, mounted on a polyethylene basis, were inserted into the right and left hemispheres of the brain of broilers, below the frontal bone of the skull, keeping a distance of 15 mm between needles. The wire electrodes were connected to a digital multimeter and the electric current was recorded in micro-amperes (µA) for each treatment. Electric current was applied to each individual bird in electrified bath using an experimental acrylic chamber according to the electrical stunning parameters of resolution 1099/2009 of the European Union. The analysis of variance indicated significant effect of broiler, frequency and system frequency for the current measured in the brain. There was no significant interaction of treatment and the application order. Detailed statistical analysis showed that the hybrid-frequency waveform system has higher currents (mean = 58.4 ± 4.4 µA) passing through the brain of the broilers compared to the results obtained by the single wave system (mean = 48.2 ± 4.1 µA). Since the hybrid wave system showed a greater flow of electric current in the brain of broilers, it is suggested that the hybrid wave system can provide better meat quality indices maintaining animal welfare. Studies about the effectiveness of stunning by electroencephalography and meat quality parameters, using this system, are needed to confirm or reject these assumptions.
4

Método alternativo para medição de isolamento sonoro em baixas frequências

Duarte, Elisabeth de Albuquerque Cavalcanti January 2011 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-graduação em Engenharia Civil, Florianópolis, 2011 / Made available in DSpace on 2012-10-26T06:26:57Z (GMT). No. of bitstreams: 1 296904.pdf: 6041910 bytes, checksum: 8b43e1aaed6fdbe129f7903c758c055e (MD5) / Nos últimos anos, tem-se percebido uma preocupação especial quanto ao isolamento sonoro em baixas frequência em edificações devido ao aumento da quantidade de fontes sonoras em diversas escalas do ambiente construído, seja nas residências, indústrias ou no meio urbano. A relevância do estudo do isolamento sonoro em baixas frequências se justifica pela sua eficiência de propagação, percorrendo grandes distâncias com baixa perda de energia, além da pobre atenuação pelos componentes da edificação, como paredes, pisos e forros nessa região do espectro sonoro. O procedimento normalizado para medição de isolamento sonoro (ISO 140) apresenta várias deficiências quando se trata de medições em baixas frequências e ambientes pequenos. Uma delas é a determinação da área de absorção da sala, que requer medições de tempo de reverberação. No entanto, isso é quase impossível em salas pequenas e em baixas frequências, devido às características modais do ambiente. A norma determina medições em salas com um volume maior que 50m3, no entanto, a maioria das salas comumente encontradas nas edificações atuais não possui esse tamanho. Esse trabalho apresenta o objetivo de desenvolver um método alternativo de medição de isolamento sonoro em baixas frequências baseado em uma fonte calibrada de velocidade de volume. Foram realizadas simulações dos modelos teóricos através do software Matlab® e, por fim, testes experimentais foram realizados a fim de validar o método proposto. Foram conseguidos bons resultados nas validações numéricas e nas experimentais para três pares de pontos posicionados nas diagonais e nas arestas da sala, o que permite a conclusão que o método pode servir como um complemento para a norma ISO 140 para medições em baixas frequências
5

Medida da corrente elétrica de frequência híbrida no cérebro de frangos para fins de insensibilização / Measurement of hybrid frequency electric current in brain\'s broilers for stunning purposes

Denis Sato 26 October 2016 (has links)
Neste estudo foram realizadas as medidas de intensidade da corrente elétrica contínua no cérebro de frangos de corte utilizando ondas de frequências híbridas e comparadas com ondas de frequências únicas. Considerando uma onda quadrada com frequência de 50 Hz, com ciclo de trabalho de 50%, a onda híbrida gera pulsos de 1500 Hz durante a metade de cada ciclo da onda, durante a fase ativa do pulso elétrico. Para cada uma das frequências híbridas utilizadas, o mesmo princípio foi aplicado. Foram utilizados 30 frangos de corte ROSS aos 42 dias de idade, com peso médio de 2,96 kg (std = 0,02), distribuídos aleatoriamente em 6 tratamentos com 5 repetições. Os tratamentos foram: 1) 50 Hz, 100 mA; 2) 200 Hz, 100 mA; 3) 400 Hz, 150 mA; 4) 50 Hz híbrida, 100 mA; 5) 200 Hz híbrida, 100 mA; e 6) 400 Hz híbrida, 150 mA. As formas de onda foram monitoradas através de um osciloscópio portátil. As aves foram abatidas e eletrodos de aço inoxidável, montados em uma base de polietileno, foram então inseridos nos hemisférios direito e esquerdo do cérebro das aves, logo abaixo do osso frontal do crânio, mantendo-se uma distância de 15 mm entre as agulhas. Os fios dos eletrodos foram conectados à um multímetro digital e a corrente elétrica foi registrada em microampères (µA), para cada um dos tratamentos. A corrente elétrica foi aplicada em cada ave individualmente, em banho eletrificado utilizando-se uma cuba experimental de acrílico e respeitando os parâmetros de insensibilização elétrica da Resolução 1099/2009 da União Europeia. A análise da variância detectou efeito significativo de frango, de sistema de frequência e de frequência para a corrente medida no cérebro dos frangos. Não houve efeito significativo da interação e da ordem de aplicação dos tratamentos. O desdobramento da análise mostrou que a onda híbrida apresenta maiores correntes (média = 58,4 ± 4,4 µA) passando pelo cérebro das aves comparado aos resultados obtidos pela onda única (média = 48,2 ± 4,1 µA). Visto que o sistema de onda híbrida apresentou um maior fluxo de corrente elétrica no cérebro de frangos de corte, sugere-se que o sistema de onda híbrida possa apresentar melhores índices de qualidade de carne mantendo o índice de bem-estar animal. Estudos sobre a eficácia da insensibilização por eletroencefalografia e parâmetros de qualidade da carne, utilizando este sistema, são necessários para se confirmar ou rejeitar tais suposições. / In this study, the intensity of the electrical direct current (DC) in the brain of broilers using hybrid-frequency waveforms system compared to single frequencies was measured. Considering a square-wave with frequency of 50 Hz (duty-cycle 50%), the hybrid-frequency waveform is obtained generating pulses at 1500 Hz in half of each cycle, in pulse-width phase. The same principle was used in the others tested hybrid frequencies. A total of 30 broilers ROSS 42 days-old with an average weight of 2.96 kg (std = 0.02), randomly distributed in a design of 6 treatments with 5 repetitions. The treatments were: 1) 50 Hz, 100 mA; 2) 200 Hz, 100 mA; 3) 400 Hz, 150 mA; 4) hybrid 50 Hz, 100 mA; 5) hybrid 200 Hz, 100 mA; and 6) hybrid 400 Hz, 150 mA. The waveforms were monitored with a portable oscilloscope. The birds were slaughtered and stainless steel electrodes, mounted on a polyethylene basis, were inserted into the right and left hemispheres of the brain of broilers, below the frontal bone of the skull, keeping a distance of 15 mm between needles. The wire electrodes were connected to a digital multimeter and the electric current was recorded in micro-amperes (µA) for each treatment. Electric current was applied to each individual bird in electrified bath using an experimental acrylic chamber according to the electrical stunning parameters of resolution 1099/2009 of the European Union. The analysis of variance indicated significant effect of broiler, frequency and system frequency for the current measured in the brain. There was no significant interaction of treatment and the application order. Detailed statistical analysis showed that the hybrid-frequency waveform system has higher currents (mean = 58.4 ± 4.4 µA) passing through the brain of the broilers compared to the results obtained by the single wave system (mean = 48.2 ± 4.1 µA). Since the hybrid wave system showed a greater flow of electric current in the brain of broilers, it is suggested that the hybrid wave system can provide better meat quality indices maintaining animal welfare. Studies about the effectiveness of stunning by electroencephalography and meat quality parameters, using this system, are needed to confirm or reject these assumptions.
6

Estudo comparativo sobre técnicas ultra-sônicas para diagnóstico da osteoporose / not available

Mori, Ricardo Naoki 18 September 1998 (has links)
As doenças ligadas ao envelhecimento, dentre elas a osteoporose, tornaram-se um dos maiores problemas de saúde pública em países que possuem alta expectativa de vida. O estudo de suas causas e de seu diagnóstico é de profunda importância tanto para paciente, como para o planejamento de saúde devido ao seu alto impacto no custo total. Equipamentos ligados ao tratamento e ao diagnóstico destas doenças devem levar em conta o custo associado ao exame, uma vez que devem atender a um grande número de pessoas. Neste estudo é apresentado um quadro geral do impacto destes custos no aspecto da saúde pública, sendo dado um tratamento especial à osteoporose. Foi realizado um resumo dos principais aspectos da doença e dos métodos mais importantes utilizados no diagnóstico da doença. Finalmente é dada uma atenção especial ao método de freqüência instantânea por apresentar aspectos interessantes, como simplicidade de implementação em relação aos métodos clássicos apresentados na literatura. / Age-related pathologies, particularly, osteoporosis, have become important health problems in high life expectancy countries. The study of causes and diagnosis of osteoporosis is of great importance for the patients, as well as for the health authorities and policy, considering the high costs involved. The development and production of equipment for diagnosis and treatment of osteoporosis must take into account the large number of patients to be surveyed and, therefore, the costs of such management. In the present work, the impact of those costs on the public health policy was studied, beginning with a general view on the main etiology and clinical aspects of osteoporosis means. Special attention was given to Mean Instantaneous Frequency Method due to its simplicity and capability to complement other classical methods reported in the literature.
7

Desenvolvimento de absorsores sonoros para baixas frequências

Costa, Ana Filipa Freitas Amorim Pinto January 2013 (has links)
Tese de Mestrado Integrado. Engenharia Civil (Construções). Faculdade de Engenharia. Universidade do Porto. 2013
8

Efeitos da magnitude e frequência do reforço em um esquema múltiplo com componentes de curta duração

Paula, Leandro Schroder de 06 December 2016 (has links)
Dissertação (mestrado)—Universidade de Brasília, Instituto de Psicologia, Departamento de Processos Psicológicos Básicos, Programa de Pós-Graduação em Ciências do Comportamento, 2016. / Submitted by Fernanda Percia França (fernandafranca@bce.unb.br) on 2017-02-15T17:05:46Z No. of bitstreams: 1 2016_LeandroSchroderdePaula.pdf: 1117322 bytes, checksum: c5c57bf5a6313bed75761987e58698f7 (MD5) / Approved for entry into archive by Raquel Viana(raquelviana@bce.unb.br) on 2017-03-23T21:56:28Z (GMT) No. of bitstreams: 1 2016_LeandroSchroderdePaula.pdf: 1117322 bytes, checksum: c5c57bf5a6313bed75761987e58698f7 (MD5) / Made available in DSpace on 2017-03-23T21:56:28Z (GMT). No. of bitstreams: 1 2016_LeandroSchroderdePaula.pdf: 1117322 bytes, checksum: c5c57bf5a6313bed75761987e58698f7 (MD5) / Este estudo investigou, em um esquema múltiplo com componentes de curta duração, (i) se a distribuição de respostas seria prevista de forma mais acurada pela frequência, pela magnitude, ou pelo tempo de acesso ao reforço; (ii) o valor das medidas de sensibilidade à frequência, magnitude e tempo de acesso ao reforço e (iii) comparar os valores de sensibilidade obtidos em esquema múltiplo, com componentes de curta duração, com os obtidos em esquema concorrente, realizado por Todorov (1973) utilizando-se do mesmo procedimento. Quatro pombos foram expostos a seis condições, utilizando três valores de frequência e de magnitude do reforço. Em cada condição as sessões foram divididas em três fases que consistiam de um esquema múltiplo intervalo variável (VI) VI. Entre fases e condições, os pombos foram expostos à 18 diferentes combinações de esquemas com diferentes frequências e magnitudes do reforço. Para todos os sujeitos, a magnitude e frequência do reforço foram melhor preditores de distribuição de respostas entre os componentes que o tempo total de acesso ao reforço, sendo a sensibilidade à frequência (M = 0,57; SE =0,004) maior que a sensibilidade à magnitude (M = 0,17; SE =0,001). / The present study aimed to verify, on multiple schedules with short component duration, (i) if response distribution would be better described by frequency and magnitude of reinforcement as two independent variables or by the total access to reinforcement, (ii) the value of behavioral sensitivity to reinforcement and (iii) to compare the values of sensitivity to frequency and magnitude of reinforcement on multiple schedules, with short duration components, with those obtained in a concurrent schedule (Todorov, 1973). Four pigeons were exposed to six conditions, manipulating three degrees of both frequency and magnitude of reinforcement. Sessions of each condition were subdivided in three phases, each composed by a mult VI VI schedule, such that subjects were exposed to all possible combinations pairs of frequency-magnitude (i.e., eighteen). For all pigeons, the data was better predicted by frequency and magnitude as two different variables. Sensitivity to reinforcement frequency (M = 0,57; SE = 0,004) was greater than sensitivity to reinforcer magnitude (M = 0,17; SE = 0,001).
9

Determinação de patologias estruturais usando modelagem numérica e transformadas de wavelet / Determination of structural pathologies using numerical modeling and wavelet transform

Silva, Ramon Saleno Yure Costa 25 February 2011 (has links)
Dissertação (mestrado)—Universidade de Brasília, Departamento de Engenharia Civil e Ambiental, 2011. / Submitted by Shayane Marques Zica (marquacizh@uol.com.br) on 2011-10-05T20:18:21Z No. of bitstreams: 1 2011_RamonSalenoYureCostaSilva.pdf: 5733814 bytes, checksum: 6f989aa90c532cee24c71a30eb0cac1a (MD5) / Approved for entry into archive by LUCIANA SETUBAL MARQUES DA SILVA(lucianasetubal@bce.unb.br) on 2011-10-19T15:15:29Z (GMT) No. of bitstreams: 1 2011_RamonSalenoYureCostaSilva.pdf: 5733814 bytes, checksum: 6f989aa90c532cee24c71a30eb0cac1a (MD5) / Made available in DSpace on 2011-10-19T15:15:29Z (GMT). No. of bitstreams: 1 2011_RamonSalenoYureCostaSilva.pdf: 5733814 bytes, checksum: 6f989aa90c532cee24c71a30eb0cac1a (MD5) / Nos últimos anos, observa-se grande interesse por parte da comunidade científica nas pesquisas associadas à detecção de danos em estruturas, utilizando métodos numéricos com objetivo de auxiliar as técnicas não destrutivas aplicadas no monitoramento do desempenho, patologia e da saúde de estruturas civis. Neste sentido, o objetivo deste trabalho é contribuir para o estudo de detecção de danos em estruturas, utilizando modelagem numérica em elementos finitos e transformadas de wavelet. Para isto, diversas situações de danos foram simuladas numericamente em vigas, treliças e pontes, e, em seguida, sinais de deslocamento e modos de vibração foram utilizados para avaliar a eficiência das transformadas de wavelet na detecção de danos para diferentes condições de contorno e de carregamentos aplicados nestas estruturas. Além disso, foi analisada a influência da introdução do ruído nos sinais usados no processo de detecção do dano. Nas simulações numéricas os programas ANSYS11.0 e SAP2000 foram utilizados para gerar os sinais de deslocamento e, também, modos de vibração de estruturas danificadas e, posteriormente, as transformadas de wavelet destes sinais foram calculadas através do programa MATLAB. Os resultados obtidos mostraram que as transformadas de wavelet são capazes de detectar danos, até mesmo, de pequenas dimensões através dos coeficientes de wavelet que alcançam grandes amplitudes na região danificada, distintamente do que ocorre em regiões sem dano onde estes coeficientes não apresentam grandes amplitudes. Assim sendo, o uso das transformadas de wavelet mostra-se promissor no processo de detecção e monitoramento de danos em estruturas. _______________________________________________________________________________ ABSTRACT / In recent years, there is a large interest in the scientific community in the researches associated on damage detection in structures using numerical methods with the goal to help in the non-destructive techniques applied to performance monitoring, pathology and structural health of civil structures. In this sense, the objective of this research is to contribute for the study of damage detection in structures using numerical finite element modeling and wavelet transforms. For this, many damage scenarios were simulated numerically in beams, trusses and bridges and then displacements signals and mode shapes were used to evaluate the efficiency of wavelet transforms in detecting damages for different boundary conditions and loadings applied to such structures. Moreover, it was analyzed the influence of noise introduction in the signals used for damage detection process. In the numerical simulations the ANSYS11.0 and SAP2000 programs were used to generate the signals of displacement and also mode shapes in damaged structures and after that, the wavelet transforms of these signals were computed using MATLAB program. The results shows that the wavelet transforms are able to detect even small damages through wavelet coefficients which achieve large amplitudes in the damaged region, differently of what takes place in regions without damage where these coefficients do not show large amplitudes. Therefore, the use of wavelet transform appears to be promising in the process of detection and monitoring damaged structures.
10

Estudo comparativo sobre técnicas ultra-sônicas para diagnóstico da osteoporose / not available

Ricardo Naoki Mori 18 September 1998 (has links)
As doenças ligadas ao envelhecimento, dentre elas a osteoporose, tornaram-se um dos maiores problemas de saúde pública em países que possuem alta expectativa de vida. O estudo de suas causas e de seu diagnóstico é de profunda importância tanto para paciente, como para o planejamento de saúde devido ao seu alto impacto no custo total. Equipamentos ligados ao tratamento e ao diagnóstico destas doenças devem levar em conta o custo associado ao exame, uma vez que devem atender a um grande número de pessoas. Neste estudo é apresentado um quadro geral do impacto destes custos no aspecto da saúde pública, sendo dado um tratamento especial à osteoporose. Foi realizado um resumo dos principais aspectos da doença e dos métodos mais importantes utilizados no diagnóstico da doença. Finalmente é dada uma atenção especial ao método de freqüência instantânea por apresentar aspectos interessantes, como simplicidade de implementação em relação aos métodos clássicos apresentados na literatura. / Age-related pathologies, particularly, osteoporosis, have become important health problems in high life expectancy countries. The study of causes and diagnosis of osteoporosis is of great importance for the patients, as well as for the health authorities and policy, considering the high costs involved. The development and production of equipment for diagnosis and treatment of osteoporosis must take into account the large number of patients to be surveyed and, therefore, the costs of such management. In the present work, the impact of those costs on the public health policy was studied, beginning with a general view on the main etiology and clinical aspects of osteoporosis means. Special attention was given to Mean Instantaneous Frequency Method due to its simplicity and capability to complement other classical methods reported in the literature.

Page generated in 0.0467 seconds