Spelling suggestions: "subject:"fundações (engenharia)"" "subject:"fundações (enegenharia)""
121 |
Análise da influência de um reforço de solo-cimento compactado na extremidade superior de estacas escavadas, sob carregamentos horizontaisFioratti, Netúlio Alarcón [UNESP] 28 August 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:25:21Z (GMT). No. of bitstreams: 0
Previous issue date: 2008-08-28Bitstream added on 2014-06-13T19:53:00Z : No. of bitstreams: 1
fioratti_na_me_ilha.pdf: 4780447 bytes, checksum: 4d7a8999b3e1a6db619819e0e04948e9 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Nesta pesquisa foi executado um reforço (cilíndrico com 1 m de diâmetro e 1 m de profundidade) de solo-cimento (cujo solo foi corrigido granulometricamente com resíduo de concreto triturado) compactado ao redor do fuste de estacas de concreto escavadas com trado mecânico (com 32 cm de diâmetro e profundidade de 8,71 m) em solo arenoso do Campo Experimental da UNESP em Ilha Solteira-SP com o intuito de avaliar sua contribuição para neutralização das cargas horizontais. A mistura entre solo e resíduo na proporção de 1:1 em massa, estabilizada com 8% de cimento (em massa seca de mistura) foi testada e mostrou-se bastante adequada para a utilização neste propósito, pois, para ser estabilizada com cimento, a mistura necessitou de menor quantidade de cimento que o solo natural (2 pontos percentuais) e o solo-cimento daí resultante apresentou resistência aos 28 dias de 6,32 MPa. Após ensaio de carregamento horizontal nas estacas reforçadas e comparação com os resultados de ensaios nas mesmas estacas sem reforço obtidos de Del Pino Jr. (2003), observou-se que para uma mesma carga aplicada os deslocamentos sofreram grande redução, enquanto para atingir um mesmo deslocamento foi necessário elevado acréscimo de carga. O coeficiente de reação horizontal do solo (nh) do conjunto estaca-solo em questão teve uma elevação da ordem de 200% do valor original. Também foram calculados os esforços (cortantes e fletores) e deslocamentos ao longo do fuste das estacas, que apresentaram sensível redução, para mesma carga aplicada, após reforço. Os resultados apontam o resíduo de concreto triturado como excelente material para correção granulométrica de solos utilizados para confecção de solocimento compactado e o solo-cimento compactado como um cilindro no entorno de estacas escavadas em solo arenoso sendo um reforço bastante eficiente para absorver esforços horizontais / This research produced one improvement (cylindrical – 1 meter diameter and 1 meter deep) made of soil-cement (wich soil was granulometrically corrected with concrete ground remains) compacted around the concrete bored piles head (32 cm diameter and 8,71 meters deep) on a sandy soil from the Trial Field of UNESP, Ilha Solteira – SP, in order to measure it’s contribution to neutralize the horizontal loading. The mix between soil and remains in proportions 1:1 in mass, stabilized with 8% of cement (dry mass of mix) was tested and proved to be very adequate for the research purpose, because the mix needed less quantity of cement than natural soil (2 percentage points) to be stabilized and the soil-cement resulting presented resistance in 28 days of 6,32 MPa. After the test of horizontal loading on the reinforced piles, compared with the results of tests with the same piles without improvement obtained from Del Pino Jr (2003), it was observed that for the same applied load the displacements had a great reduction, while for reaching the same displacement need high load increasing. The coefficient of the soil’s horizontal reaction (nh) from the set pile-soil concerned has it’s value increased to 200% from the original value. Also were measured the efforts and displacements along the stem piles, that had significant reduction after improvement. Results indicate ground concrete remains as an excellent material for granulometric correction of soil for confection of compacted soil-cement and the compacted soil-cement as a cylinder around the excavated piles head on sandy soil proved to be very efficient to absorb horizontal efforts
|
122 |
Comportamento de blocos de coroamento sobre estacas em perfil W com ligações através de chapas e por contato diretoRonaldo Burgos Filho 01 December 2016 (has links)
Atualmente no Brasil a utilização de perfis metálicos em fundações profundas vem aumentando consideravelmente. A produção padronizada de acordo com normas específicas recentes tem influência direta nessa mudança de cenário, visto que o uso de
perfis metálicos apresenta algumas vantagens quando comparado com outros tipos de estacas para certas características de subsolo. A NBR 6122:2010 - Projeto e Execução de Fundações recomenda que o sistema de transferência dos esforços (de compressão, horizontais, de tração e momento) do bloco de coroamento para as estacas metálicas
deve ser estudado e detalhado juntamente com o projetista da estrutura. O tipo de ligação pode ser por chapas, fretagem ou através de vergalhões soldados com a finalidade de efetuar transferência de esforços por aderência. O modelo de bielas e tirantes pode ser utilizado para o dimensionamento do bloco sobre estacas. Onde admite que a carga recebida pelo bloco originária do pilar é transmitida internamente até as estacas por elementos de concreto comprimidos delimitados pelos caminhos das tensões principais de compressão. Levando em conta que a seção transversal de um perfil
metálico possui pequena área quando comparado com os demais tipos de estacas a solução de ligação por contato direto pode resultar em elevadas tensões entre os materiais envolvidos na ligação. Com o objetivo de analisar o comportamento dessa ligação, foram modelados através de elementos finitos, dois blocos sobre quatro estacas
metálicas com ligações através do uso de chapas auxiliares sobre as estacas do bloco 1 e por contato direto das estacas no bloco 2, além do cálculo de um modelo pelo método analítico. Os resultados obtidos mostram a viabilidade na segurança estrutural no uso da ligação de perfis metálicos com bloco de coroamento em concreto armado por contato direto, ao menos para os modelos adotados, e sua compatibilização com o modelo de bielas e tirantes utilizados no dimensionamento estrutural de blocos. / Currently in Brazil the use of metal profiles in deep foundations is increasing considerably. The standardized production according to recent specific rules has a direct influence on this change scenario, since the use of metal profiles has some advantages when compared to other types of cuttings for certain subsurface features. The NBR
6122: 2010 - Design and Execution of Foundations recommends that the stress transfer system (compression, horizon, traction and momentum) of the crowning block for the metal stations should be studied and detailed together with the designer of the structure.
The type of bond may be a bars, or by haulage rods welded in order to make efforts for adhesion transfer. The strut and tie model can be used for sizing the pile cap on which admits the load received by block originating internally of the pillar is transmitted to the piles by compressed concrete elements delimited by the paths of the main compression stresses. Taking into account the cross section of the metal profile has small area when compared to the other types of cuttings binding solution with plate can compensate for this lower area of value increasing contact between the metal materials and the concrete pile cap. With the objective of analyzing the behavior of this connection, two pile cap on four metal stakes were modeled through finite elements with connections through the use of auxiliary plates on the stakes of pile cap 1 and by simple soaking of the stakes in
pile cap 2, besides calculation of the model by the analytical method. The results show the feasibility of structural safety in the use of bonding of metallic profiles with crown pile cap in reinforced concrete by simple embedding, at least for the models adopted, and its compatibility with the model of rods and tie rods used in the structural design of pile cap.
|
123 |
Estudo do arrancamento de fundações em solos tratados com cimento / The uplift performance of footings embedded in cement stabilized backfillRuver, Cesar Alberto January 2011 (has links)
Engenheiros geotécnicos, defrontam-se frequentemente com solos de baixa capacidade de suporte. Para viabilizar projetos nestes materiais, pode-se utilizar fundações com grandes dimensões e/ou melhorar a propriedades mecânicas destes solos. Fundações de grandes dimensões podem ser extremamente onerosas e gerar impactos ambientais indesejáveis provocados por grandes movimentações de solo. Em contrapartida, o melhoramento das propriedades mecânicas do solo pode ser obtido por meio de tratamento com agentes cimentantes. Esta técnica tem-se mostrado bastante promissora nas diversas subáreas da geotecnia, como por exemplo, leito e subleito de pavimentação, estabilidade de taludes e terrenos para assentamento de fundações à compressão. A utilização desta técnica em fundações escavadas submetidas à tração ainda é incipiente. Até meados dos anos 1950, os métodos de previsão de desempenho consideravam somente o peso do solo contido em uma superfície ruptura somado ao peso da fundação, como contribuindo na capacidade de carga ao arrancamento. Estudos recentes passaram a incluir uma terceira parcela de resistência devido à resistência ao cisalhamento do solo. A partir de então diversos autores passaram a estudar técnicas de melhoramento e reforços dos reaterros. Num primeiro momento, foi estudada a influência das técnicas de compactação do reaterro e a substituição do material por outro com melhores propriedades. Atualmente, os estudos concentram-se no reforço dos reaterros com geossintéticos e adição de agentes cimentícios. Neste contexto, o objetivo deste trabalho é realizar um estudo avaliando os benefícios gerados pelo aumento da capacidade de carga, de fundações escavadas e reaterradas com areia fina e homogênea (proveniente da cidade de Osório/RS), cimentada, avaliando sua influência em termos das propriedades geométricas (diâmetro das fundações, profundidade de assentamento e diâmetro de tratamento) e geotécnicas (coesão, ângulo de atrito e módulo de elasticidade, influenciados pelo teor de cimento). Para tanto foram realizadas provas de carga à tração, variando-se o diâmetro (30 e 45 cm), profundidades de embutimentos (entre 0,5 e 2,0), e teores de cimento (0%, 3% e 7%). Através das provas de carga, verificou-se que o aumento do teor de cimento e da profundidade de assentamento aumentam a capacidade de carga à tração. Os resultados experimentais foram reproduzidos pelo método de elementos finitos por meio de retroanálise. A partir do modelo numérico gerado pela retroanálise, foram executadas duas análises paramétricas. Na primeira foram definidos os parâmetros significativos – coesão e embutimento – e determinada uma equação adimensional para determinação da carga máxima para tratamento de uma camada infinita. Na segunda análise foram definidos ábacos para determinação da perda de carga em função da redução do diâmetro de tratamento, para três níveis de cimentação – baixa, média e alta. / Geotechnical engineers frequently have to deal with soils that have reduced strength. In order to carry out the design of footings in such materials, their base has to be quite large and/or mechanical properties of the soils have to be improved. Shallow foundations of large dimensions can be extremely expensive and generate undesirable environmental impacts due to large soil movements. As an alternative, the improvement of mechanical properties of the local soil can be obtained by treating it with cementitious agents. Such technique has been used with success in several earthworks such as the improvement of base and sub-base of pavements, slope stability and particularly as a soil-cement mixture of a compacted layer over a low bearing capacity soil. The use of such technique in footings subjected to pullout forces is still insipient. Until middle 1950’s, pullout design methodologies of shallow foundations embedded in soil backfills considered only the weight of the soil contained inside a specific failure surface plus the foundation self-weight as the pullout failure load. Further studies included the shear strength of the soil at the failure surface. Since then several authors considered several techniques to improve and/or reinforce the backfills. At first the influence of backfill compaction and material substitution to improve soil properties were considered. Nowadays, studies concentrate in the reinforcement of backfills with geosynthetics and in the addition of cementitious agents. In such context, the main aim of present work is to carry out a research evaluating the benefits towards the improvement of uplift performance of footings embedded in cemented stabilized backfill, analyzing the influence of the geometrical characteristics of the problem (diameter of the footings, depth of embedment and size of the improved area) and geotechnical properties of the backfill (cohesion intercept, friction angle and Young’s modulus), the latter influenced by the amount of cementitious agents inserted on the soil. For doing so, several pullout tests were carried out varying foundation diameter (0.30 and 0.45 m), embedment depth according foundation diameter (ranging from 0.5 e 2.0) and cement contents (0%, 3% and 7%) in the stabilized backfill. Results of pullout tests have shown that the increase of cement content and embedment depth of the backfill increased uplift capacity. Field results were reproduced through a back-analysis using the finite element technique. In the sequence, two distinct parametrical analyses were also carried out. In the first analysis the parameters that show significance were cohesion intercept and embedment depth – a non-dimensional equation determining the failure pullout load (considering infinite horizontal improvement) was determined. In the second analysis distinct abacus were produced to allow considering reduction of horizontal treatment area for three cementation levels – low, medium e high.
|
124 |
Analise de variáveis-chave no controle da resistência mecânica de solos artificialmente cimentados / Analysis of key-parameters for the strength control of artificially cemented soilsFoppa, Diego January 2005 (has links)
Freqüentemente, a utilização de técnicas tradicionais da engenharia geotécnica depara-se com obstáculos de caráter econômico e ambiental. A técnica do solo-cimento torna-se atrativa quando a melhora das propriedades do solo do local constitui-se numa alternativa de projeto. A técnica de tratamento de solos com cimento encontra aplicação, por exemplo, na construção de bases para pavimentos, na proteção de taludes em barragens de terra e como camada de suporte para fundações superficiais. Entretanto, ainda não existem metodologias de dosagem e projeto das misturas de solo-cimento baseadas em critérios racionais como existe, por exemplo, para o concreto, onde a relação água/cimento desempenha papel fundamental na obtenção da resistência desejada. Nesse sentido, este estudo tem por objetivo quantificar a influência do teor de cimento, da porosidade e do teor de umidade de moldagem, sobre a resistência mecânica de um solo arenoso artificialmente cimentado e avaliar a adequação do uso das relações água/cimento e vazios/cimento na estimativa da sua resistência à compressão simples. Para isso foram realizados ensaios de compressão simples, triaxiais não-drenados e medidas de sucção matricial. Os resultados mostram que a resistência à compressão simples cresceu linearmente com o aumento do teor de cimento e exponencialmente com a redução na porosidade da mistura compactada. Além disso, a variação do teor de umidade de moldagem afetou significativamente a resistência à compressão simples em misturas compactadas numa mesma massa específica aparente seca. Verificou-se que, para o solo-cimento no estado não-saturado (estado em que normalmente se encontram os aterros compactados), o fator água/cimento não é um bom parâmetro para estimativa da resistência à compressão simples. Ao contrário, a relação vazios/cimento, definida pela razão entre a porosidade da mistura compactada e o teor volumétrico de cimento, ajustado por um expoente, demonstrou ser o parâmetro mais adequado na estimativa da resistência à compressão simples do solo-cimento estudado. / Often, the use of traditional techniques in geotechnical engineering faces obstacles of economical and environmental nature. The soil-cement technique becomes attractive when the improvement of the local soil is a project alternative. The treatment of soils with cement finds application, for instance, in the construction of pavement base layers, in slope protection of earth dams and as a support layer for shallow foundations. However, there are no dosage methodologies based on a rational criteria as it exists in the case of the concrete technology, where the water/cement ratio plays a fundamental role in the assessment of the target strength. In that sense, this study aims to quantify the influence of the amount of cement, the porosity and the moisture content on the strength of a sandy soil artificially cemented, as well as to evaluate the use of a water/cement ratio and a voids/cement ratio to assess its unconfined compression strength. A number of unconfined compression tests, undrained triaxial tests and measures of matric suction were carried out. The results show that the unconfined compression strength increased linearly with the increase of the amount of cement and exponentially with the reduction in the porosity of the compacted mixture. Besides, the change in moisture content has remarkably affected the unconfined compression strength of mixtures compacted in a same dry density. It was verified that, for the soil-cement in the unsaturated state (state usually met by compacted fills), the water/cement ratio is not a good parameter for assessment of unconfined compression strength. In the other hand, the voids/cement ratio, defined by the reason between the porosity of the compacted mixture and the volumetric cement content, adjusted by an exponent, demonstrated to be the most appropriate parameter in the assessment of unconfined compression strenght of the studied soil-cement.
|
125 |
Estudo da incorporação de resíduos de cerâmica vermelha na composição de concreto para uso em estacas moldadas in loco /Wada, Patrycia Hanna. January 2010 (has links)
Orientador: Antonio Anderson da Silva Segantini / Banca: Adriano Souza / Banca: David de Carvalho / Resumo: A preocupação com o meio ambiente tem estimulado o interesse por pesquisas voltadas para o desenvolvimento sustentável. O presente trabalho objetivou estudar o reaproveitamento de resíduos de cerâmica vermelha (RCV) na composição de concreto, em substituição em massa ao agregado miúdo (areia), visando a sua utilização em estacas do tipo moldadas in loco. Foram confeccionados concretos com substituição de 20%, 40%, 60% e 80% de areia natural (em massa) pelo RCV. Realizaram-se ensaios de compressão simples e de módulo de elasticidade em todos os traços no estado endurecido e, no estado fresco, ensaios de incorporação de ar e de massa específica. Visando avaliar o seu comportamento em condições de campo, frente às ações de trabalho, foram confeccionadas três estacas de concreto com 40% de RCV, as quais foram submetidas à prova de carga por meio de ensaio rápido. Os resultados das provas de carga foram comparados com os de outros ensaios realizados no mesmo local, porém com estacas de concreto convencional. Concluiu-se que o reaproveitamento do RCV melhorou as características físicas e mecânicas do concreto e possibilitou a sua aplicação nas estacas em estudo. / Abstract: Concern for the environment has stimulated interest in research for sustainable development. The present work aimed investigated the reuse of red ceramic waste (RCW) in the concrete composition, replacing in weight to fine aggregate (sand) and proposing his application in cast-in-place piles foundations. Were made compositions with 20%, 40%, 60% and 80% of sand by RCW replacement. Compressive strength tests and modulus of elasticity were performed for all compositions of hardened concrete. Testing of air entraining and density were also made in the concrete in its fresh state. In order to evaluate his behavior under field conditions, on work load situation, three foundation piles were made, which were submitted the quick load test. The piles were made with 20.0 cm diameter and 4.50 m length using concrete with 40% replacement. The results obtained were compared with others load test carried at the same place, however with conventional concrete piles. It was concluded that reuse of RCW improved the physical characteristics and mechanics of concrete and its possible application in the piles foundation in study. / Mestre
|
126 |
Análise da influência de um reforço de solo-cimento compactado na extremidade superior de estacas escavadas, sob carregamentos horizontais /Fioratti, Netúlio Alarcón. January 2008 (has links)
Orientador: Antonio Anderson da Silva Segantini / Banca: Adriano Souza / Banca: Miriam Gonçalves Miguel / Resumo: Nesta pesquisa foi executado um reforço (cilíndrico com 1 m de diâmetro e 1 m de profundidade) de solo-cimento (cujo solo foi corrigido granulometricamente com resíduo de concreto triturado) compactado ao redor do fuste de estacas de concreto escavadas com trado mecânico (com 32 cm de diâmetro e profundidade de 8,71 m) em solo arenoso do Campo Experimental da UNESP em Ilha Solteira-SP com o intuito de avaliar sua contribuição para neutralização das cargas horizontais. A mistura entre solo e resíduo na proporção de 1:1 em massa, estabilizada com 8% de cimento (em massa seca de mistura) foi testada e mostrou-se bastante adequada para a utilização neste propósito, pois, para ser estabilizada com cimento, a mistura necessitou de menor quantidade de cimento que o solo natural (2 pontos percentuais) e o solo-cimento daí resultante apresentou resistência aos 28 dias de 6,32 MPa. Após ensaio de carregamento horizontal nas estacas reforçadas e comparação com os resultados de ensaios nas mesmas estacas sem reforço obtidos de Del Pino Jr. (2003), observou-se que para uma mesma carga aplicada os deslocamentos sofreram grande redução, enquanto para atingir um mesmo deslocamento foi necessário elevado acréscimo de carga. O coeficiente de reação horizontal do solo (nh) do conjunto estaca-solo em questão teve uma elevação da ordem de 200% do valor original. Também foram calculados os esforços (cortantes e fletores) e deslocamentos ao longo do fuste das estacas, que apresentaram sensível redução, para mesma carga aplicada, após reforço. Os resultados apontam o resíduo de concreto triturado como excelente material para correção granulométrica de solos utilizados para confecção de solocimento compactado e o solo-cimento compactado como um cilindro no entorno de estacas escavadas em solo arenoso sendo um reforço bastante eficiente para absorver esforços horizontais / Abstract: This research produced one improvement (cylindrical - 1 meter diameter and 1 meter deep) made of soil-cement (wich soil was granulometrically corrected with concrete ground remains) compacted around the concrete bored piles head (32 cm diameter and 8,71 meters deep) on a sandy soil from the Trial Field of UNESP, Ilha Solteira - SP, in order to measure it's contribution to neutralize the horizontal loading. The mix between soil and remains in proportions 1:1 in mass, stabilized with 8% of cement (dry mass of mix) was tested and proved to be very adequate for the research purpose, because the mix needed less quantity of cement than natural soil (2 percentage points) to be stabilized and the soil-cement resulting presented resistance in 28 days of 6,32 MPa. After the test of horizontal loading on the reinforced piles, compared with the results of tests with the same piles without improvement obtained from Del Pino Jr (2003), it was observed that for the same applied load the displacements had a great reduction, while for reaching the same displacement need high load increasing. The coefficient of the soil's horizontal reaction (nh) from the set pile-soil concerned has it's value increased to 200% from the original value. Also were measured the efforts and displacements along the stem piles, that had significant reduction after improvement. Results indicate ground concrete remains as an excellent material for granulometric correction of soil for confection of compacted soil-cement and the compacted soil-cement as a cylinder around the excavated piles head on sandy soil proved to be very efficient to absorb horizontal efforts / Mestre
|
127 |
Modelagem numérica com elementos finitos de arrancamento de fundações em solos tratados com fibraSiacara, Adrian Torrico January 2017 (has links)
objetivo principal do trabalho é determinar a capacidade última de tração (arrancamento) de uma fundação com solo tratado no topo a partir de uma modelagem numérica com o programa computacional Abaqus a partir dos ensaios feitos em solos tratados. Os modelos numéricos foram feitas a partir dos ensaios ao arrancamento em solos tratados por Ruver, 2011 e Girardello, 2014 para um aterro de areia (proveniente da cidade de Osório/RS) e areia com fibra (monofilamentos de polipropileno). Foi feito um modelo numérico inicial com as propriedades geotécnicas de ensaios feitos em laboratório e campo para depois fazer um ajuste do modelo com os ensaios ao arrancamento. Foi avaliado o modelo numérico de areia e areia-fibra para as tensões iniciais, deslocamentos inciais e a etapa geostatic porque não só é ter bons resultados nas figuras do ajuste, mas se ter um modelo numérico bem feito que apresente um comportamento próximo da realidade numericamente. Foram avaliados os benefícios gerados pelo aumento da capacidade de carga de fundações escavadas e reaterradas com areia fina e homogênea, areia-fibra, avaliando sua influência geotécnica (coesão, ângulo de atrito e módulo de elasticidade) a partir de uma análise paramétrica. Foi feito um método de dimensionamento e estimativa da capacidade ao arrancamento para um aterro com areia e areia-fibra a partir das metodologias internacionais e os modelos numéricos. / The main objective of the work is to determine the ultimate traction (pullout) capacity of a foundation with treated soil at the top from a numerical modeling with the Abaqus computational program from the tests on treated soils. The numerical models were made from the pullout tests on soils treated by Ruver, 2011 and Girardello, 2014 for a sand dump (from the city of Osório / RS) and sand with fiber (polypropylene monofilaments). An initial numerical model was made with the geotechnical properties of laboratory and field tests to later calibrate the model with the pullout tests. It was evaluated the numerical model of sand and sand-fiber for the initial stresses, displacements and the geostatic step because not only is it to have good results in the figures of the calibration, but it is necessary to have a well-designed numerical model that presents behavior close to reality numerically. It was evaluated the benefits generated by the increase of the load capacity of excavated foundations and recovered with fine sand and homogeneous, sand-fiber, evaluating its geotechnical influence (cohesion, friction angle and modulus of elasticity) from a parametric analysis. A method of dimensioning and estimation of the pullout capacity for a backfill with sand and sand-fiber was done from the international methodologies and the numerical models.
|
128 |
Comportamento de um solo residual levemente cimentado : estimativa de capacidade de carga para estacas submetidas a esforços transversaisCarretta, Mariana da Silva January 2018 (has links)
Fundações profundas, quando solicitadas ao carregamento lateral, são regidas por três critérios de projeto: resistência última do solo, carga última do elemento estrutural e deflexão máxima. Esses critérios atuam em conjunto e é necessário que sejam analisados dessa forma, visto que a falha de um deles é capaz de acarretar o colapso de todo sistema. No que tange à resistência do solo, metodologias de capacidade de carga existentes traduzem o comportamento de solos granulares e coesivos. Dada a particularidade da atuação de solos residuais na mecânica dos solos, não há uma metodologia abrangente para estacas sujeitas a solicitação de carregamento lateral nesse tipo de solo, o qual apresenta comportamento intermediário e estrutura levemente cimentada. Em vista disso, o presente trabalho propõe um método de estimativa de capacidade de carga para estacas carregadas horizontalmente, quando inseridas em solo residual e em casos em que as mesmas apresentam topo locado em superfície de solo tratado. Dessa forma, dados de provas de carga lateral pré-existentes e ensaios de laboratório executados ao longo da pesquisa serviram como base para a proposição do método, fundamentado no comportamento do material quando solicitado ao carregamento lateral Ensaios de resistência à compressão simples, compressão oedométrica, compressão isotrópica e ensaios triaxiais com medidas de módulo cisalhante demonstram que há um ponto em que se dá a quebra da estrutura cimentada do solo, passando o mesmo a se apresentar num arranjo desestruturado, refletido em maiores deformações. Uma relação linear é capaz de equacionar a capacidade de carga, tanto para estacas inseridas em solo residual quanto para estacas executadas em solo com camada superficial melhorada. Essa relação é estabelecida entre a carga de ruptura das estacas ensaiadas e a área de solo adjacente à mesma, mobilizada pelo carregamento. Os resultados demonstram que a capacidade de carga das estacas estudadas é regida pela tensão de plastificação do material. O equacionamento proposto possibilita a obtenção da carga de ruptura com base em ensaios simples e de fácil execução, tal como o ensaio de resistência à compressão simples que estabelece relação direta com a tensão de plastificação do solo estudado. / Deep foundations, when requested to lateral loading, are governed by three design criteria: ultimate soil strength, piles’ ultimate load, and maximum deflection. These criteria act together and must be analyzed in this way, since the failure of one of them is capable of causing the collapse of the entire system. Regarding soil resistance, the current bearing capacity methodologies describe the behavior of granular and cohesive soils. Given the particular behavior of the residual soils in the soil mechanics, there is no comprehensive methodology for piles subject to lateral loads and inserted in this soil type, which presents an intermediate behavior and a lightly cemented structure. Thus, the present work proposes an estimated bearing capacity for crosswise loaded piles, when inserted in residual soil and in soil with the top layer cemented. So, data from preexisting lateral loading tests and laboratory tests, performed during the research, served as a basis for the proposition of the method, based on the behavior of the material when requested to lateral loading Unconfined compression tests, oedometer consolidation tests, isotropic compression, and triaxial tests with measures of shear modulus demonstrate that there is a point where the soil's cemented structure breaks down, presenting itself in a destructured arrangement, reflected by larger strains. A linear relationship is capable of equating the bearing capacity for both, piles inserted in residual soil and piles carried out in soil with improved surface layer. This relationship is established between the rupture load of the piles tested and the area of soil adjacent to it mobilized by the loading. The results shows that the piles' bearing capacity is governed by the yield stress of the material. The proposed equation makes it possible to obtain the rupture load based on simple and easy tests, such as the unconfined compression test that establishes a direct relationship with the yield stress of the studied soil.
|
129 |
Capacidade de carga de fundações sobre solos reforçados por colunas submetidas a solicitações inclinadas / Bearing capacity of a column-reinforced soil foundation under inclined loadingArévalos Burró, María Alicia January 2015 (has links)
O dimensionamento de fundações apoiadas sobre solos reforçados por colunas representa um desafio devido à natureza composta do mesmo e à grande quantidade de inclusões envolvidas no processo de reforço. Do ponto de vista do cálculo da capacidade de carga, as metodologias de dimensionamento propostas na literatura tratam ou de cálculos empíricos, ou de cálculos analíticos para carregamentos puramente verticais, ou utilizam o método de elementos finitos através de análises elasto-plásticas incrementais. No presente trabalho estuda-se, através da análise limite, a capacidade de carga de fundações superficiais apoiadas sobre solos argilosos reforçados por colunas submetidas a cargas inclinadas. Assim, este trabalho constitui uma primeira referência em analisar o efeito do reforço no diagrama de interação que relaciona às componentes da carga. Inicialmente, realizou-se uma análise em estado plano de deformação para um solo reforçado por uma coluna isolada. Foram construídos campos de tensões lineares por trecho, estaticamente admissíveis e que satisfazem o critério de resistência, determinando limites inferiores da capacidade de carga. Trata-se da abordagem estática da análise limite. Na sequência, através da utilização de mecanismos de ruptura cinematicamente admissíveis, foram encontrados limites superiores da capacidade de carga. Trata-se da abordagem cinemática da análise limite. A construção de ábacos permitiu realizar um estudo paramétrico da melhora da capacidade de carga em função dos parâmetros adimensionais, definidos pela geometria e propriedades de resistência. Finalmente, realizou-se uma generalização à situação de um solo reforçado por um grupo de colunas, em estado plano de deformação, mediante a aplicação da abordagem estática e cinemática da análise limite e posterior estudo paramétrico. Os resultados mostraram que, a medida que aumenta a componente horizontal da força, a componente vertical de ruptura diminui. Este fato constitui um risco na edificação de estruturas submetidas a carregamentos inclinados. Os parâmetros adimensionais que controlam a capacidade de carga são: o ângulo de atrito interno do material de reforço e a relação entre o intercepto coesivo do reforço e do solo. Foi encontrado que, para fins práticos, a carga limite é independente da quantidade de colunas, sempre que o volume de reforço seja mantido. / From a practical engineering viewpoint, design of column-reinforced foundations turns to be a challenging task owing to the strong heterogeneity of the geo-composite resulting from the association of native soft soil and the reinforcing soil columns. The design procedures conceived to estimate bearing capacity improvement from this reinforcement technique have mainly dealt with foundations under vertical loading. The purpose of the present work is to investigate the ultimate bearing capacity problem of column-reinforced foundations under inclined loading, within the framework of limit analysis theory. Special emphasis is given to the effect of reinforcement on the interaction diagram relating the foundation load components. Starting from the situation of an isolated column, a lower bound solution for the bearing capacity is derived, in plain strain analysis, by considering statically admissible piecewise linear stress fields that comply with the failure condition everywhere in the foundation soil. On the other hand, the kinematic approach of limit analysis makes it possible, through the implementation of failure mechanisms on the column-reinforced structure, to derive upper bound estimates of the bearing capacity for each value of the inclination angle of applied load. The semi-analytical expressions of both lower and upper bound estimates allow for a parametric study on the improvement of the bearing capacity as a function of dimensionless parameters, which are defined from geometrical and strength properties. In this context, design charts are presented to provide an insight into the reinforcement mechanism. Finally, the generalization of the approaches to the situation of a soil reinforced by a group of columns is presented, considering plain strain analysis. As soon as the horizontal component of the force increases, the vertical component of the bearing capacity decreases. This fact constitutes a risk for structures submitted to inclined loading. The dimensionless parameters that control the bearing capacity are: the reinforcement material friction angle and the relation between the coesion intercept of the reinforcement and the soil. For practical purposes, the bearing capacity doesn’t depend on the column number, but on the reinforcement volume.
|
130 |
Estacas hélice segmentada: execução, verificação de integridade e estudo do comportamento. / Segmented flight auger piles: execution, integrity verification and behavior study.Alexsander Silva Mucheti 10 December 2008 (has links)
O trabalho apresenta o histórico e o desenvolvimento dos equipamentos de estacas hélice segmentada, que surgiram no ano de 2002. Atualmente já existe um número representativo de equipamentos em operação no mercado, confirmando a boa aceitação do processo pelo meio técnico. São detalhados os aspectos executivos deste tipo de fundação e investiga-se o risco de sua execução no aspecto operacional, no que se refere à integridade da estaca, caso não sejam observados padrões ou regras adequadas pelas empresas executoras. Foram executados ensaios de integridade (PIT) em 10 estacas hélice segmentadas, instaladas em São Bernardo do Campo SP, com particularidades executivas diversificadas e em terreno com características distintas, que permitiram verificar a confiabilidade dos gráficos de monitoração da perfuratriz. Ainda neste trabalho, apresenta-se resultado de prova de carga instrumentada, feita numa estaca hélice segmentada de 30 cm de diâmetro e 12 m de comprimento, instalada no Campo Experimental de Fundações e Mecânica dos Solos da UNICAMP. A estaca foi submetida a carregamentos lento e rápido, estáticos e à compressão, e seus resultados são comparados com os de provas de carga em estacas tipo hélice contínua, de mesmo comprimento, feitas anteriormente no local. Ao término, apresentam-se algumas recomendações baseadas na pesquisa e no acompanhamento de obras, podendo-se assim, avaliar padrões de boa e má execução. / This work presents the history and development of segmented flight auger equipment, which appeared in 2002 in Brasil. Nowadays there is already a considerable number of equipments being operated in the market, confirming the well acceptance of the process in the technical field. The executive aspects on this type of foundation are detailed and it is investigated the risk of its execution in the operational aspect regarding the pile integrity, in case patterns or adequate rules are not observed by the pile companies. Pile integrity tests have been carried out in 10 segmented flight augers installed in São Bernardo do Campo SP, with executive particularities in diversified fields with distinguished characteristics, which allowed to check the reliability of monitoring graphs from the drilling machine. In addition, it is shown the result of an instrumented loading test, carried out on a segmented flight auger of 30 cm diameter and 12 m length, installed at the Experimental Field of Foundation and Soil Mechanics at UNICAMP. The pile was submitted to slow and quick static loading compression tests. A comparison is made with the results of load tests on continuous flight auguer, of the same length, done before on this site. Finally, some recommendations are presented based on the research and on the follow-up of constructions, allowing to evaluate patterns of good and bad execution.
|
Page generated in 0.0582 seconds