Spelling suggestions: "subject:"samma dpectroscopy"" "subject:"samma espectroscopy""
31 |
Analysis of '1'3'7Cs contamination in soil using in-situ gamma spectrometryMacDonald, Julian January 1999 (has links)
No description available.
|
32 |
Busca de oligoelementos em rochas vulcânicas / Search of Oligoelements in Volcanic StonesGuillaumon, Pedro Vinícius 25 August 2014 (has links)
Foram realizadas medidas de espectroscopia gama simples, de espectroscopia gama-gama em anti-coincidência e coincidência em dezessete amostras de rochas vulcânicas irradiadas com nêutrons térmicos. Foram determinadas, utilizando cálculo covariante, 33 elementos químicos (Al, As, Ba, Ca, Ce, Cl, Co, Cr, Cs, Dy, Eu, Fe, Hf, K, La, Lu, Mg, Mn, Na, Nd, Rb, Sb, Sc, Sm, Sr, Ta, Tb, Th, Ti, U, Yb, Zn e Zr), dos quais 21 elementos traço. Foi determinado o limite máximo de detecção para o irídio em 11 amostras. Foi obtido um valor máximo de 0,7 ppb. Os resultados foram comparados com o processo astrofísico de formação da Terra. A concentração de urânio e tório variou entre 3 ppm e 9 ppm, com exceção das amostras de Kilimanjaro, que variou entre 40 ppm e 45 ppm. Abaixo da concentração de 12 ppm presentes na crosta terrestre. Espera-se concentrações menores devido a estimativas de tório e urânio através do calor emitido pela Terra. Foram determinados 10/17 lantanídeos, com destaque para a abundância de Ce em Kilimanjaro, cujos valores obtidos foram de 272 (6) ppm e 319 (11) ppm. / Single gamma ray spectroscopy, gama-gama coincidence and anticoincidence spectroscopy have been performed to study 17 volcanic rocks irradiated with neutrons. We have determined, using covariant calculations, 33 chemical elements including 21 trace elements: Al, As, Ba, Ca, Ce, Cl, Co, Cr, Cs, Dy, Eu, Fe, Hf, K, La, Lu, Mg, Mn, Na, Nd, Rb, Sb, Sc, Sm, Sr, Ta, Tb, Th, Ti, U, Yb, Zn e Zr. We set a maximum limit of detection for iridium in 11 samples. We have determined a maximum value of 0,7 ppb. The results were associated to the astrophysical process that led to the Earth formation. Thorium and uranium abundance ranged between 3 ppm e 9 ppm, except for the samples of Kilimanjaro, which ranged from 40 ppm to 45 ppm. Less than 12 ppm, the Earth\'s Crust abundance of thorium and uranium. Using the heat emitted by Earth to estimate the abundance of them led to significant lower values. We have also determined 10/17 lanthanides, like Ce that has an abundance of 272 (6) ppm and 319 (11) ppm, in the case of Kilimanjaro\'s samples.
|
33 |
Implantação de 111In em Ligas de Heusler Pd2MnZ (Z=Sn,Sb,Ge,In) usando Reações Nucleares com Ions Pesados: Medida de Campo Hiperfino Magnético pela Espectroscopia de Correlação Angular Gama-Gama Perturbada / Implantation of 111In in Heusler Alloys Pd2MnZ (Z=Sn,Sb,Ge,In) using Nuclear Reaction with Heavy Ions: Measurements of Hiperfine Field Magnetic for Spectroscopy of Perturbed Angular Correlation Gamma-GammaPasca, Gabriel Adolfo Cabrera 16 November 2005 (has links)
O presente trabalho apresenta uma metodologia nova de introduzir o núcleo de prova 111In em amostras para medidas de Correlação Angular Gama-Gama Perturbada (CAP). Para esta finalidade utilizou-se reação nuclear do tipo 108Pd(6Li,3n)111In. Para testar o método de implantação iônica foram utilizadas amostras de compostos intermetalicas tipo liga de Heusler Pd2MnZ onde Z=Sn,Sb,Ge,In. O trabalho demonstra que, para as amostras nas quais o paládio é um dos componentes do alvo da reaçãoo, o processo de implantaçãoo de 111In usando esta reação nuclear é muito eficiente comparada com os métodos convencionais usados para introduzir este núcleo de prova. Após a implantação do núcleo de prova 111In foram realizadas medidas de Correlação Angular gama-gama Perturbada Diferencial em Tempo (CAPDT), utilizando um espectrometro gama com quatro detectores de BaF2 que gera 12 espectros de coincidências gama-gama atrasada. Utilizou-se nestas medidas a bem conhecida cascata gama de 172-245 keV do 111Cd populado no decaimento do 111In pela captura eletrônica. O nível intermediário do 111Cd a 245 keV com spin I=5/2 e T1/2 = 85 ns foi usado para medir o campo hiper¯no magnético Bhf do 111Cd nas ligas de Heusler. As medidas foram realizados na faixa de temperatura entre 10 a 295 K. A presente metodologia de implantação do 111In é comparada com outros métodos convencionais de introduzir o núcleo de prova nas amostras para medidas de CAP. Os resultados de Bhf são comparados e discutidos com resultados de medidas anteriores. / The present work describes a new and e±cient method to introduce the 111In nuclear probe in the samples for Perturbed Gama-Gama Angular Correlation (PAC) measurements. For this purpose a heavy ion nuclear reaction 108Pd(6Li,3n)111In was used. To test the ion implantation process we have used the samples of intermetallic compounds Pd2MnZ (Z=In, Sn, Ge, Sb) known as Heusler Alloys. It is shown that for samples, which contain Pd as one of the components of the reaction target the process of implantation of 111In using this reaction is much more eficient as compared to the other conventional methods of introducing the this probe nuclei. After the 111In nuclear probe implantation in the Heusler alloys these were measured by the Time Differential Perturbed Gamma-Gamma Angular Correlation (TDPAC) method using a gamma spectrometer consisting of four BaF2 detectors, which generates 12 simultaneous delayed gamma-gamma coincidence spectra. The well-known gamma cascade of 172-245 keV in 111Cd populated through electron capture decay of 111In has been used for the TDPAC measurements. The intermediate level of 111Cd at 245 keV with spin, I = 5/2 and half-life, T1=2 = 85ns was used to measure the hyperfine magnetic field (Bhf) in the Heusler alloys. The measurements were carried out in the temperature range of 10-295 K. The present ion implantation methodology is compared with other conventional methods of introducing the probe nuclei in samples for PAC measurements. The present results of magnetic hyperfine felds are discussed and compared with the results of earlier measurements.
|
34 |
Avaliação da radioatividade natural em tintas de uso comercial no Brasil / Assessment of natural radioactivity in wall paints of commercial use in BrazilFonseca, Leandro Milhomens da 29 April 2016 (has links)
A radioatividade natural presente em solos, rochas e materiais de construção, devida ao 40K e às séries radioativas do 232Th e 238U é a principal contribuição à exposição externa aos seres humanos. Neste trabalho, determinou-se as concentrações de atividade de 226Ra (da série do 238U), 232Th e 40K presentes em 50 amostras de tintas látex de cor branca comercializadas no Brasil, especificamente, 15 do tipo econômico, 15 do tipo standard, 20 do tipo premium e em uma amostra de dióxido de titânio. As amostras foram seladas e armazenadas por um período mínimo de 30 dias para se alcançar o equilíbrio radioativo secular nas séries do 238U e do 232Th e medidas pela técnica analítica de espectrometria gama de alta resolução. As concentrações de atividade foram calculadas utilizando-se as médias ponderadas pelas incertezas do 214Pb e 214Bi para o 226Ra e médias ponderadas pelas incertezas do 228Ac, 212Pb e 212Bi para o 232Th. A concentração de atividade do 40K foi determinada pela sua transição única de 1460,8 keV. Fatores de autoatenuação gama foram calculados e utilizados para correção da concentração de atividade das amostras com densidade maior que 1,0 g.cm-3. Os índices radiológicos equivalente em rádio (Raeq), índice de concentração de atividade (Iγ), índice de risco à exposição gama interna (Hin), o índice de risco à exposição gama externa (Hex) e a taxa de dose (D) e dose efetiva anual (Def) foram calculados a partir das concentrações de atividade do 226Ra, 232Th e 40K. As concentrações de atividade de 226Ra das tintas variaram entre valores abaixo da atividade mínima detectável e 38,7 Bq.kg-1, as de 232Th variaram entre valores abaixo da atividade mínima detectável e 101,2 Bq.kg-1 e as de 40K variaram entre valores abaixo da atividade mínima detectável e 256 Bq.kg-1. O Raeq variou entre 1,41 Bq.kg-1 e 203 Bq.kg-1, o Iγ variou entre 0,0047 e 0,720, o Hin variou entre 0,0076 e 0,653 e o Hex variou entre 0,0038 e 0,549. A taxa de dose variou de 0,170 nGy.h-1 a 21,3 nGy.h-1 e a dose efetiva anual variou entre 0,83 μSv.a-1 e 104,2 μSv.a-1. Estes resultados mostram que as concentrações de atividades das tintas utilizadas neste estudo estão abaixo dos limites recomendados por Hassan et al. para Raeq (370 Bq.kg-1), pela Comissão Européia para o Iγ (limite de 2 para materiais superficiais) e pela Organização para Cooperação Econômica e Desenvolvimento para Hin e para Hex (ambos com limite de 1), para todas as 50 amostras estudadas, mostrando assim a segurança destas tintas com relação a proteção radiológica. / Natural radioactivity in soils, rocks and construction materials, due to 40K and the natural series of 232Th and 238U, is the main contribution to external exposure in mankind. In this work, activity concentrations of 226Ra (238U serie), 232Th and 40K were determined for 50 white latex wall paints samples, commercialized in Brazil, namely 15 Economic quality samples, 15 Standard quality samples and 20 Premium quality samples and for a single titanium dioxide sample. The samples were tightly sealed and stored for a minimum period of 30 days, to reach the radioactive secular equilibrium from 238U and 232Th series, then measured by high resolution gamma ray spectrometry. The activity concentration was determined using the weighted average concentrations of 214Pb and 214Bi for 226Ra and 228Ac, 212Pb and 212Bi for 232Th. The 40K activity concentration was determined by its single transition of 1460.8 keV. Self attenuation correction factors of the samples whose densities are higher than 1.0 g.cm-3, were determined and used to make the necessary corrections. The radiological indices radium equivalent activity (Raeq), activity concentration index (Iγ), internal exposure risk index (Hin) and external exposure risk index (Hex) and also the absorbed dose rate (D) and annual effective dose (Def) were calculated from the activity concentrations of 226Ra, 232Th and 40K. The activity concentration values for 226Ra ranged from under the minimum detectable activity to 38.7 Bq.kg-1, for 232Th from under the minimum detectable activity to 101.2 Bq.kg-1 and for 40K from under the minimum detectable activity to 256 Bq.kg-1. Raeq ranged from 1.41 Bq.kg-1 to 203 Bq.kg-1, Iγ ranged from 0.0047 to 0.720, Hin from 0.0076 to 0.653 and Hex from 0.0038 to 0.549. The absorbed dose rate ranged from 0.170 nGy.h-1 and 21.3 nGy.h-1 and the annual effective dose ranged from 0.83 μSv and 104.2 μSv. The results show that the activity concentrations of the wall paints studied in this work are below the recommended limits by Hassan et al. for Raeq (370 Bq.kg-1), by European Commission for Iγ (limit of 2 for superficial materials) and by the Organisation for Economic Co-operation and Development for Hin and Hex (both with limit of 1), for all the 50 samples, assuring the safety of these wall paints with respect to radiological protection.
|
35 |
ESPECTROSCOPIA GAMA DO 100Rh / GAMMA SPECTROSCOPY OF 100Rh.Kenchian, Garabed 17 November 1995 (has links)
O esquema de decaimento beta do 100.ANTPOT Rh foi estudado a partir de medidas de espectroscopia gama simples e coincidência gama-gama. Foram observadas e atribuídas ao decaimento beta do 100.ANTPOT Rh 132 transições gama, das quais 68 pela primeira vez. Um número de 32 estados excitados do 100.ANTPOT Rh foram observados sendo que os de energia 2512 keV, 2536 keV, 2543 keV, 2569 keV, 2666 keV, 2745 keV, 2774 keV, 2801 keV e 3072 keV pela primeira vez a partir do decaimento do 100.ANTPOT Rh. Os valores de spin e paridade de vários estados foram propostos com base nas transições observadas nos valores de log(ft) obtidos e nas informações de trabalho anteriores. A meia-vida do decaimento do 100.ANTPOT Rh também foi medida e o valor obtido foi de 20,2(1) h. Um tratamento estatístico levando em conta a covariância foi utilizado no cálculo das energias das transições gama e dos níveis, das intensidades de transição gama e de alimentação beta. Os estados excitados experimentais para o 100.ANTPOT Rh foram comparados com os obtidos do modelo de bósons interatuantes. Observou-se que este modelo, no limite algébrico SU(5) (correspondendo a um vibrador do modelo geométrico) com a inclusão da interação de 3 bósons (relacionada com deformação triaxial), produz um esquema de níveis bastante compatível com o esquema experimental. / The beta decay scheme of 100.ANTPOT Rh has been studied through simple gamma spectroscopy and gamma-gamma spectroscopy. With these two measurements, 132 gamma transitions have been observed and scribed to the 100.ANTPOT Rh decay, 68 of them for the first time. A number of 32 excited states of 100.ANTPOT Rh have been observed and some of them for the first time in the beta decay of 100.ANTPOT Rh (2512 keV, 2536 keV, 2543 keV, 2569 keV, 2666 keV, 2745 keV, 2774 keV, 2801 keV, and 3072 keV). A 20.2h half lofe for the beta decay of 100.ANTPOT Rh has been measured and spin and parity values for several states have been proposed, taking into account the observed transitions, the calculated log(ft) values and the beta intensities. A covariant statistical treatment has been used to calculate gamma transitions energies and intensities, level energies and beta feeding intensities. The experimental excited states of 100.ANTPOT Rh have been compared with those obtained from the interacting boson model. The algebraic SU(5) limit of this model (that correspond to an oscillator in the geometrical model), with the inclusion of 3 boson interaction (related with triaxial deformation), produces a level scheme in good agreement with experimental data.
|
36 |
Determination of the astrophysical S(E) factor for the 16O+16O reaction / Determinação do fator S(E) astrofísico para a reação 16O+16ODuarte, Jeremias Garcia 02 February 2015 (has links)
This work aims to obtain the fusion excitation function for the 16O+16O system through gamma-spectroscopy measurements and gamma-charged particle coincidence, using the Saci-Perere system mounted at the end of the 30A beamline of the Open Laboratory of Nuclear Physics of the University of São Paulo (LAFN). Tests with the gamma-charged particle detection system indicated its unfeasibility due to the short measurement time and lose of the neutron channel. To overcome this problem, a new experimental setup was used. Two $\\gamma$-ray detectors were placed at 55º and 125º and a surface barrier detector was placed at 130º to monitor the 16O nuclei backscattered. The partial fusion cross sections related to the exit channels from the 16O+16O fusion reaction were measured by detecting their characteristic gamma rays at Ecm= 8.27, 9.27, 10.77 and 12.27 MeV. Three difficulties were faced during and after the experiment: carbon contamination of the target, natural background and low beam intensity. Efforts were made to successfully overcome these difficulties. The relative normalization was made by two ways, using the gamma-rays at 279 keV(197Au) and 536 keV(100Mo), and their results agree very well with each other. The total fusion cross section was obtained by summing the partial cross sections for each beam energy. Its absolute normalization was performed with the total theoretical fusion cross section obtained using coupled channel calculations, using the zero point motion model (ZPM), at Ecm= 12.27 MeV. With the total fusion cross section we calculated the astrophysical S-factor, and both results are in good agreement with the literature. / O objetivo deste trabalho é obter uma função de excitação para o sistema 16O+16O através de medidas de espectroscopia-gamma e coincidência gamma-partícula carregada, utilizando o sistema Saci-Perere montado no final da linha de feixe 30A do Laboratório Aberto de Física Nuclear da Universidade de São Paulo (LAFN). Testes com o sistema de detecção gamma-partícula carregada indicaram sua inviabilidade devido ao curto tempo de medida e a perda do canal de nêutrons. Para superarmos este problema, uma nova configuração experimental foi utilizada. Dois detectores de radiação gamma foram posicionados a 55º e 125º e um detector de barreira de superfície foi posicionado a 130º para monitorar os núcleos de 16O retroespalhados. As seções de choque parciais relativas aos canais de saída da reação de fusão 16O+16O foram medidas através da detecção de seus raios-gamma característicos para Ecm= 8.27, 9.27, 10.77 e 12.27 MeV. Três dificuldades foram encontradas ao longo e após o experimento: contaminação do alvo por carbono, radiação natural de fundo e baixa intensidade do feixe. Esforços foram direcionados com sucesso para superar estas dificuldades. A normalização relativa foi realizada por dois caminhos, utilizando os raios-gamma a 279 keV(197Au) e a 536 keV(100Mo), e seus resultados concordam muito bem. A seção de choque de fusão total foi obtida somando as seções de choque parciais para cada energia de feixe medida. Sua normalização absoluta foi feita usando a seção de choque de fusão teórica total obtida com cálculos de canais acoplados, utilizando o modelo (ZPM), para Ecm= 12.27 MeV. De posse da seção de choque de fusão total calculamos o fator S-astrofísico, e ambos os resultados concordam bem com a literatura.
|
37 |
Determinação de parâmetros nucleares do núcleo de 127Te: uma proposta para o ensino de física nuclear / Nuclear parameters determination of the 127Te β- decay: a proposal for teaching nuclear physicsBatista, Wagner Fonseca 24 February 2011 (has links)
Um estudo do decaimento β- do 127Te, via espectroscopia gama, foi realizado utilizando um detector de HPGe de alta resolução. As medidas foram realizadas na região de energia de 30 keV a 1,0 MeV, com o objetivo de obter uma melhor compreensão de sua estrutura nuclear. As fontes radioativas de 127Te foram obtidas a partir da reação nuclear 126Te(n,γ)127Te, produzidas no reator IEA-R1 do IPEN/CNEN-SP. Cinco transições anteriormente atribuídas a este decaimento foram confirmadas com melhor precisão. Foi realizada também a medida da meia-vida do 127Te com incerteza significativamente menor. Utilizando um conjunto dos dados experimentais, selecionados da medida de espectroscopia gama, foi elaborada e aplicada uma proposta didática para alunos do Ensino Médio utilizando o programa Excel. / A study of the 127Te β- decay was carried out by means of gamma spectroscopy measurements using high resolution HPGe detector, in the region from 30 keV to 1.0 MeV, aiming to get a better understanding of the 127Te nuclear structure. The radioactive sources of 127Te were obtained from the 126Te(n,γ)127Te nuclear reaction produced in the IEA- R1 nuclear reactor at IPEN/CNEN-SP. Five gamma transitions previously attributed to this decay were confirmed with a better precision than previously. The half-life of 127Te was also studied resulting in data with lower uncertainty. Using a set of data selected from gamma spectroscopy measurements was developed and applied a didactic proposal for high school students using the Excel software.
|
38 |
ESPECTROSCOPIA GAMA DO 100Rh / GAMMA SPECTROSCOPY OF 100Rh.Garabed Kenchian 17 November 1995 (has links)
O esquema de decaimento beta do 100.ANTPOT Rh foi estudado a partir de medidas de espectroscopia gama simples e coincidência gama-gama. Foram observadas e atribuídas ao decaimento beta do 100.ANTPOT Rh 132 transições gama, das quais 68 pela primeira vez. Um número de 32 estados excitados do 100.ANTPOT Rh foram observados sendo que os de energia 2512 keV, 2536 keV, 2543 keV, 2569 keV, 2666 keV, 2745 keV, 2774 keV, 2801 keV e 3072 keV pela primeira vez a partir do decaimento do 100.ANTPOT Rh. Os valores de spin e paridade de vários estados foram propostos com base nas transições observadas nos valores de log(ft) obtidos e nas informações de trabalho anteriores. A meia-vida do decaimento do 100.ANTPOT Rh também foi medida e o valor obtido foi de 20,2(1) h. Um tratamento estatístico levando em conta a covariância foi utilizado no cálculo das energias das transições gama e dos níveis, das intensidades de transição gama e de alimentação beta. Os estados excitados experimentais para o 100.ANTPOT Rh foram comparados com os obtidos do modelo de bósons interatuantes. Observou-se que este modelo, no limite algébrico SU(5) (correspondendo a um vibrador do modelo geométrico) com a inclusão da interação de 3 bósons (relacionada com deformação triaxial), produz um esquema de níveis bastante compatível com o esquema experimental. / The beta decay scheme of 100.ANTPOT Rh has been studied through simple gamma spectroscopy and gamma-gamma spectroscopy. With these two measurements, 132 gamma transitions have been observed and scribed to the 100.ANTPOT Rh decay, 68 of them for the first time. A number of 32 excited states of 100.ANTPOT Rh have been observed and some of them for the first time in the beta decay of 100.ANTPOT Rh (2512 keV, 2536 keV, 2543 keV, 2569 keV, 2666 keV, 2745 keV, 2774 keV, 2801 keV, and 3072 keV). A 20.2h half lofe for the beta decay of 100.ANTPOT Rh has been measured and spin and parity values for several states have been proposed, taking into account the observed transitions, the calculated log(ft) values and the beta intensities. A covariant statistical treatment has been used to calculate gamma transitions energies and intensities, level energies and beta feeding intensities. The experimental excited states of 100.ANTPOT Rh have been compared with those obtained from the interacting boson model. The algebraic SU(5) limit of this model (that correspond to an oscillator in the geometrical model), with the inclusion of 3 boson interaction (related with triaxial deformation), produces a level scheme in good agreement with experimental data.
|
39 |
Determinação de parâmetros nucleares do núcleo de 127Te: uma proposta para o ensino de física nuclear / Nuclear parameters determination of the 127Te β- decay: a proposal for teaching nuclear physicsWagner Fonseca Batista 24 February 2011 (has links)
Um estudo do decaimento β- do 127Te, via espectroscopia gama, foi realizado utilizando um detector de HPGe de alta resolução. As medidas foram realizadas na região de energia de 30 keV a 1,0 MeV, com o objetivo de obter uma melhor compreensão de sua estrutura nuclear. As fontes radioativas de 127Te foram obtidas a partir da reação nuclear 126Te(n,γ)127Te, produzidas no reator IEA-R1 do IPEN/CNEN-SP. Cinco transições anteriormente atribuídas a este decaimento foram confirmadas com melhor precisão. Foi realizada também a medida da meia-vida do 127Te com incerteza significativamente menor. Utilizando um conjunto dos dados experimentais, selecionados da medida de espectroscopia gama, foi elaborada e aplicada uma proposta didática para alunos do Ensino Médio utilizando o programa Excel. / A study of the 127Te β- decay was carried out by means of gamma spectroscopy measurements using high resolution HPGe detector, in the region from 30 keV to 1.0 MeV, aiming to get a better understanding of the 127Te nuclear structure. The radioactive sources of 127Te were obtained from the 126Te(n,γ)127Te nuclear reaction produced in the IEA- R1 nuclear reactor at IPEN/CNEN-SP. Five gamma transitions previously attributed to this decay were confirmed with a better precision than previously. The half-life of 127Te was also studied resulting in data with lower uncertainty. Using a set of data selected from gamma spectroscopy measurements was developed and applied a didactic proposal for high school students using the Excel software.
|
40 |
Avaliação da radioatividade natural em tintas de uso comercial no Brasil / Assessment of natural radioactivity in wall paints of commercial use in BrazilLeandro Milhomens da Fonseca 29 April 2016 (has links)
A radioatividade natural presente em solos, rochas e materiais de construção, devida ao 40K e às séries radioativas do 232Th e 238U é a principal contribuição à exposição externa aos seres humanos. Neste trabalho, determinou-se as concentrações de atividade de 226Ra (da série do 238U), 232Th e 40K presentes em 50 amostras de tintas látex de cor branca comercializadas no Brasil, especificamente, 15 do tipo econômico, 15 do tipo standard, 20 do tipo premium e em uma amostra de dióxido de titânio. As amostras foram seladas e armazenadas por um período mínimo de 30 dias para se alcançar o equilíbrio radioativo secular nas séries do 238U e do 232Th e medidas pela técnica analítica de espectrometria gama de alta resolução. As concentrações de atividade foram calculadas utilizando-se as médias ponderadas pelas incertezas do 214Pb e 214Bi para o 226Ra e médias ponderadas pelas incertezas do 228Ac, 212Pb e 212Bi para o 232Th. A concentração de atividade do 40K foi determinada pela sua transição única de 1460,8 keV. Fatores de autoatenuação gama foram calculados e utilizados para correção da concentração de atividade das amostras com densidade maior que 1,0 g.cm-3. Os índices radiológicos equivalente em rádio (Raeq), índice de concentração de atividade (Iγ), índice de risco à exposição gama interna (Hin), o índice de risco à exposição gama externa (Hex) e a taxa de dose (D) e dose efetiva anual (Def) foram calculados a partir das concentrações de atividade do 226Ra, 232Th e 40K. As concentrações de atividade de 226Ra das tintas variaram entre valores abaixo da atividade mínima detectável e 38,7 Bq.kg-1, as de 232Th variaram entre valores abaixo da atividade mínima detectável e 101,2 Bq.kg-1 e as de 40K variaram entre valores abaixo da atividade mínima detectável e 256 Bq.kg-1. O Raeq variou entre 1,41 Bq.kg-1 e 203 Bq.kg-1, o Iγ variou entre 0,0047 e 0,720, o Hin variou entre 0,0076 e 0,653 e o Hex variou entre 0,0038 e 0,549. A taxa de dose variou de 0,170 nGy.h-1 a 21,3 nGy.h-1 e a dose efetiva anual variou entre 0,83 μSv.a-1 e 104,2 μSv.a-1. Estes resultados mostram que as concentrações de atividades das tintas utilizadas neste estudo estão abaixo dos limites recomendados por Hassan et al. para Raeq (370 Bq.kg-1), pela Comissão Européia para o Iγ (limite de 2 para materiais superficiais) e pela Organização para Cooperação Econômica e Desenvolvimento para Hin e para Hex (ambos com limite de 1), para todas as 50 amostras estudadas, mostrando assim a segurança destas tintas com relação a proteção radiológica. / Natural radioactivity in soils, rocks and construction materials, due to 40K and the natural series of 232Th and 238U, is the main contribution to external exposure in mankind. In this work, activity concentrations of 226Ra (238U serie), 232Th and 40K were determined for 50 white latex wall paints samples, commercialized in Brazil, namely 15 Economic quality samples, 15 Standard quality samples and 20 Premium quality samples and for a single titanium dioxide sample. The samples were tightly sealed and stored for a minimum period of 30 days, to reach the radioactive secular equilibrium from 238U and 232Th series, then measured by high resolution gamma ray spectrometry. The activity concentration was determined using the weighted average concentrations of 214Pb and 214Bi for 226Ra and 228Ac, 212Pb and 212Bi for 232Th. The 40K activity concentration was determined by its single transition of 1460.8 keV. Self attenuation correction factors of the samples whose densities are higher than 1.0 g.cm-3, were determined and used to make the necessary corrections. The radiological indices radium equivalent activity (Raeq), activity concentration index (Iγ), internal exposure risk index (Hin) and external exposure risk index (Hex) and also the absorbed dose rate (D) and annual effective dose (Def) were calculated from the activity concentrations of 226Ra, 232Th and 40K. The activity concentration values for 226Ra ranged from under the minimum detectable activity to 38.7 Bq.kg-1, for 232Th from under the minimum detectable activity to 101.2 Bq.kg-1 and for 40K from under the minimum detectable activity to 256 Bq.kg-1. Raeq ranged from 1.41 Bq.kg-1 to 203 Bq.kg-1, Iγ ranged from 0.0047 to 0.720, Hin from 0.0076 to 0.653 and Hex from 0.0038 to 0.549. The absorbed dose rate ranged from 0.170 nGy.h-1 and 21.3 nGy.h-1 and the annual effective dose ranged from 0.83 μSv and 104.2 μSv. The results show that the activity concentrations of the wall paints studied in this work are below the recommended limits by Hassan et al. for Raeq (370 Bq.kg-1), by European Commission for Iγ (limit of 2 for superficial materials) and by the Organisation for Economic Co-operation and Development for Hin and Hex (both with limit of 1), for all the 50 samples, assuring the safety of these wall paints with respect to radiological protection.
|
Page generated in 0.0692 seconds