• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 70
  • 21
  • 9
  • 6
  • 4
  • 3
  • 3
  • 2
  • 1
  • 1
  • Tagged with
  • 157
  • 157
  • 157
  • 157
  • 37
  • 34
  • 34
  • 33
  • 30
  • 30
  • 28
  • 28
  • 19
  • 17
  • 17
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
91

Development of improved methods for the characterisation of organic chemicals emitted into indoor air by building and furnishing products

Brown, Veronica M. January 2013 (has links)
A wide range of organic compounds are released from building and furnishing products and these have the potential to adversely affect indoor air quality. There are growing international requirements for testing and controlling these emissions for the protection of public health. The test methods require specialist analytical chemistry facilities based on thermal desorption/gas chromatography/mass spectrometry (TD/GC/MS). This project has addressed the need for better performance and greater automation of the analysis, as well as development of simpler screening tests. A variety of products were tested using screening techniques, with an emission cell method being used as a reference test. Short duration tests, using a micro-scale chamber at slightly elevated temperature, were shown to have the potential to predict emissions occurring during longer term reference tests. Multi-sorbent air sampling tubes, that have the potential to extend the volatility range of compounds determined by a single TD/GC/MS analysis, were compared with Tenax TA tubes specified by current standard methods. This showed no difference in performance for the range of compounds for which Tenax is optimal, with improved performance for a number of more volatile compounds. The determination of formaldehyde was investigated using 2-hydroxymethylpiperidine as a derivatising agent, followed by TD/GC/MS. The results showed the possibility of this method being developed as an alternative to the current standard method that involves solvent elution and liquid chromatography. The performance of a newly developed time-of-flight mass spectrometer was compared with a standard quadrupole instrument. This showed its potential, with the use of re-collection, to extend the concentration range of compounds quantified from a single air sample, of particular benefit for the determination of carcinogens. New compound identification software was applied to increase automation of analysis of the TD/GC/MS data. Good correlation with manual processing was achieved, demonstrating the possibility of routine application to material emissions testing.
92

De levandes gåvor och de dödas efterlämningar : -En kemisk analys på harts och ökendadel (Balanites aegyptiaca) från två egyptiska kärl

Biström Freij, Felicia January 2014 (has links)
This paper aims to investigate the embalming process and the Balanites aegyptiaca from two pottery originated in ancient Egypt. The two objects were from Medelhavsmuseet in Stockholm. Samples were collected and analyzed with Fourier transform infrared spectrometry (FTIR) and Gas chromatography/mass spectrometry to identify which components the samples contained. The results show complex mixtures mainly consisting of resin origin from Pinaceae and the vegetable oils from the Balanites aegyptiaca.
93

Furan measurement in transformer oil by UV-Vis spectroscopy using fuzzy logic approach

Lai, Sin Pin January 2009 (has links)
An Ultraviolet to Visible (UV-Vis) spectroscopic analysis based on fuzzy logic approach has been developed for furan content measurement in transformer oil. Following the successful identification and quantification of furan derivatives in transformer oil by ASTM D5837 standard, the new approach is able to approximate the furan content more conveniently and economically. As furan concentration level would determine the absorption intensity in UV-Vis spectral range, the fuzzy logic software model developed would exploit this characteristic to aggregate the furans content level in transformer oil. The UV-Vis spectral response at other ambient temperature is also studied. The proposed technique provides a convenient alternative to conventional method of furan measurement by High Performance Liquid Chromatography (HPLC) or Gas Chromatography Mass Spectrometry (GC/MS) in ASTM D5837 Standard.
94

Desenvolvimento de polímeros de impressão molecular para microextração em ponteiras de bisfenol A em amostras de urina e análise por GC-MS / Development of molecularly imprinted polymer for disposable pipette extraction of bisphenol A in biological samples and analysis by GC-MS

Tamires Amabile Valim Brigante 26 October 2015 (has links)
O Bisfenol A (BPA, acrônimo da língua inglesa - bisphenol A) é uma substância utilizada na fabricação de embalagens alimentícias e resinas odontológicas. Sua toxicidade deve-se ao fato de que, como disruptor endócrino, afeta o sistema reprodutor, cardiovascular, neuro-endócrino e pode apresentar potencial carcinogênico. Em métodos bioanalíticos, o preparo da amostra tem sido requerido para aumentar a seletividade e sensibilidade analítica, através da remoção dos interferentes da amostra biológica e concentração dos analitos, quase sempre presentes em níveis de traços. A microextração em ponteiras (DPX, acrônimo das iniciais em língua inglesa - Disposable Pipette Extraction), baseada no equilíbrio de sorção do soluto com a fase extratora, consiste em uma ponteira padrão de micropipeta modificada, na qual o sorvente está contido livremente entre dois filtros, permitindo rápida extração do analito em diferentes matrizes complexas. Os polímeros de impressão molecular (MIP acrônimo das iniciais em língua inglesa - Molecularly Imprinted Polymer) consistem em uma rede polimérica tridimensional que possui cavidades seletivas para o reconhecimento molecular do analito ou de substâncias de estrutura análoga. Essa rede polimérica é sintetizada ao redor da substância molde (analito), e a cavidade seletiva é formada após a remoção do molde. As vantagens do processo sol-gel para a síntese do MIP são o controle do tamanho e forma das partículas, ajuste da hidrofobicidade e alta estabilidade térmica. No presente trabalho, o MIP foi sintetizado e utilizado como sorvente para a técnica DPX para a determinação de bisfenol A em amostras de urina por cromatografia em fase gasosa acoplada à espectrometria de massas (GC-MS, acrônimo das iniciais em língua inglesa - Gas Chromatography coupled to Mass Spectrometry). O MIP foi sintetizado pela via sol-gel utilizando aminopropiltrietoxisilano (APTES) como mônomero funcional e tetraetil-orto-silicato (TEOS) como reagente de ligação cruzada. Como molde foram avaliados o BPA para o MIP, e o tetrabromobisfenol A (TBBPA) para o polímero molecularmente impresso com molécula análoga ao analito (DMIP, acrônimo das iniciais em língua inglesa - Dummy Molecularly Imprinted Polymer). Para avaliar a seletividade do MIP, o polímero não impresso (NIP, acrônimo das iniciais em língua inglesa - Non-imprinted Polymer) foi sintetizado seguindo o mesmo procedimento de síntese do MIP com exceção da adição da molécula molde. Apesar de a capacidade de sorção do MIP ser ligeiramente maior, o DMIP foi selecionado como sorvente para minimizar o efeito de memória. O DMIP foi caracterizado por microscopia eletrônica de varredura (MEV) e por espectroscopia vibracional na região do infravermelho por transformada de Fourier (FTIR, acrônico das inicias em língua inglesa - Fourier Transform Infrared). Os parâmetros da técnica DPX, tais como, o tempo de equilíbrio de sorção entre a amostra e o sorvente e condições de dessorção foram otimizadas por técnicas quimiométricas. A robustez do DMIP sintetizado via sol-gel foi comprovada pela reutilização deste sorvente por mais de 100 vezes, sem perda da eficiência da extração. O método desenvolvido DPX/GC-MS apresentou linearidade na faixa de 50 a 500 ng mL-1, precisão com CV (coeficientes de variação) entre 4 e 14% e de exatidão com valores de erro padrão relativo (EPR) de -13,6 a 12,3%. O método de referência utilizando a extração líquido-líquido e GC-MS (LLE/GC-MS), faixa de linearidade de 5 a 50 ng mL-1, foi desenvolvido e validado. Embora o método DPX/GC-MS inovador, quando comparado ao LLE/GC-MS, tenha apresentado maior limite de quantificação, apresentou as seguintes vantagens: simplicidade, rapidez e utilização de menores volumes de amostra e de solventes orgânicos na etapa do preparo da amostra / Bisphenol A (BPA) is widely used in food package and dental resins manufacturing. Its toxicity is due to its endocrine disruptor activity that affects the reproductive, cardiovascular, neurological system and may have carcinogenic potential. In bioanalytical methods the sample preparation has been required to increase the selectivity and analytical sensibility by removing the interfering from the biological matrix and concentration of the analytes that are in trace levels most of the times. The disposable pipette extraction (DPX) is based on sorption equilibrium of the analyte between the sample and the extraction phase. It consists in a pipette that contais the sorbent phase freely between two filters. Then, the extraction of the solute from the complex sample occurs quickly. Molecularly imprinted polymer is a tridimensional polimeric network that has selectivity cavities that can recognize an analyte or a substance with a similar structure. The polimeric network is synthesized around to a template molecule and after removing this template, a selective cavity is formed. The advantages of the sol-gel process for the synthesis of MIP are the control of the size and shape of the particles, hydrophobicity adjustment and high thermal stability. In the present study MIP was synthesized and used as sorbent to DPX method for determination of BPA in urine samples by gas chromatography coupled to mass spectrometry (GC-MS). Sol-gel methodoly was used to synthesize the polymers. Aminopropyltriethoxysilane (APTES) was used as a functional monomer and tetraethyl orthosilicate (TEOS) as crosslinking reagent. BPA and tetrabromobisphenol A (TBBPA) were evaluated as template to the synthesis of MIP and dummy molecularly imprinted polymer (DMIP) which is a molecularly imprinted polymer that uses a template structurally similar to the analyte. The non-imprinted polymer (NIP) was synthesized following the same procedure that MIP, except for the addition of template. It was made to verify the improvement of selectivity and sensibility of molecularly imprinted polymers. Although the sorption capacity of the MIP is slightly larger, DMIP has been selected as a sorbent in order to minimize the memory effect. The DMIP was characterized by Scanning Electron Microscopy (SEM) and Fourier Transform Infrared spectroscopy (FTIR). The parameters of DPX, such as time sorption equilibrium between the sample and the sorbent and desorption conditions were optimized by chemometrics. Robustness of DMIP sinthesized by sol-gel process was evidenciated for the reuse of DMIP for more than a 100 times. The developed method DPX/GC-MS showed linearity on the range from 50 to 500 ng ml-1, precision values with coefficient of variation (CV) betweeen 4 and 14% and accuracy with relative standard deviation values (RSD) from -13.6 to 12.3%. The reference method using liquid- liquid extraction and GC-MS (LLE/GC-MS) was developed and validated, showing linearity from 0.5 to 50 ng mL-1. Althout the innovative method DPX/GC-MS has showed limit of quantification larger than LLE/GC-MS, it presents the following advantages: simplicity, rapidy and utilization of smaller volumes of organic solvents on the sample preparation step
95

Étude de l'absorption instestinale du cholestérol chez l'homme à l'aide des marqueurs directs et indirects : influence des facteurs nutritionnels et génétiques / Study of intestinal cholesterol absorpion in humans by direct and indirect markers : influence of nutritional and genetic factors

Wolff, Estelle 03 December 2010 (has links)
Deux approches ont été mises au point et utilisées afin de mieux comprendre les facteurs nutritionnels, physiopathologiques et génétiques intervenant dans la grande variabilité d'absorption du cholestérol chez l'homme (30-80%) :- le dosage de marqueurs plasmatiques d'absorption et de synthèse du cholestérol (METHODE INDIRECTE), qui s'applique aux grandes cohortes.- le dosage simultané de deux isotopes stables du cholestérol utilisés comme traceurs (METHODE DIRECTE), qui est la méthode de référence pour déterminer le taux d'absorption du cholestérol alimentaire.Nous avons déterminé, par la méthode indirecte, des interactions gène-régime-sexe, dans une population mixte présentant un risque cardiovasculaire modéré.On a montré qu'en modifiant les habitudes alimentaires, le statut d'absorption du cholestérol d'un sujet n'était pas modifié après 3 mois de régime méditerranéen, quel que soit le sexe. De plus la diminution du cholestérol circulant (LDL-C) induite par le régime de type méditerranéen était plus marquées chez les faibles absorbeurs de cholestérol. Le statut d'absorbeur est donc stable dans le temps et sous différents régimes, mais il module la réponse au régime, illustrant l'importance de ce statut dans la prise en charge nutritionnelle personnalisée des sujets. Nous avons aussi établi une interaction gène-régime sur le polymorphisme génétique du gène de la microsomal triglyceride transfer protein (-493G/T). Ce polymorphisme module le niveau d'absorption du cholestérol chez les femmes sous un régime occidental et cet effet est aboli sous un régime méditerranéen.La méthode indirecte présente cependant des limites. Aussi avons-nous mis au point une méthode de dosage directe originale, basée sur l'abondance relative des isotopomères du cholestérol, le but étant de mesurer simultanément les marqueurs directs et indirects et de comparer les deux méthodes en vue de l'application systématique de la méthode indirecte dans différentes études chez l'homme. / Two approaches were used to better understand nutritional, physio-pathological and genetic factors intervening in the great inter-individual variability of cholesterol absorption in humans (30-80%) : - INDIRECT METHOD consisting in the determination of both absorption and synthesis plasmatic markers of cholesterol, which is used in large scale studies; - a DIRECT METHOD by measuring simultaneaously two cholesterol stable isotopes, used as tracers. It is the "gold" method to determine the absorption percentage of dietary cholesterol. By using indirect method, we have shown gene-diet interactions according to sex in a population of men and women with moderate cardiovascular risks. Changing in dietary habits didn't alter cholesterol absorption statuts after 3 months of mediterranean type diet, whatever the sex. Moreover, the lowering of plasma LDL-cholesterol induced by mediterranean type diet was more marked in low-cholesterol absorbers. Thus, the cholesterol absorption status is stable over time and under differents regimes, but it modulates responsiveness to a dietary challenge. These findings illustrate the importance of cholesterol absorption status in personalized nutrition recommendations. Another finding is a gene-diet interaction in the -493G/T gene polymorphism of the microsomal triglyceride transfer protein. This polymorphism modulates the level of cholesterol absorption in women under a western diet, an effect abolished under a prudent mediterranean type diet. As indirect method shows limits, we established an original direct method, based on relative abundance of cholesterol isotopomers. Our goal is to measure simultaneously both direct and indirect plasmatic markers. Then, we could compare the two methods with the objective of applying systematically indirect method in different studies in humans.
96

Evaluation of the Scent Collection System for Its Effectiveness in Volatile Organic Compound Collection and Use in Canine Training

Sanchez, Claudia L, Ms 16 March 2015 (has links)
As a result of increased terrorist activity around the world, the development of a canine training aid suitable for daily military operations is necessary to provide effective canine explosive detection. Since the use of sniffer dogs has proven to be a reliable resource for the rapid detection of explosive volatiles organic compounds, the present study evaluated the ability of the Human Scent Collection System (HSCS) device for the creation of training aids for plasticized / tagged explosives, nitroglycerin and TNT containing explosives, and smokeless powders for canine training purposes. Through canine field testing, it was demonstrated that volatiles dynamically collected from real explosive material provided a positive canine response showing the effectiveness of the HSCS in creating canine training aids that can be used immediately or up to several weeks (3) after collection under proper storage conditions. These reliable non-hazardous training aids allow its use in areas where real explosive material aids are not practical and/or available.
97

Avaliação da qualidade das aguas destinadas ao abastecimento publico na região de Campinas : ocorrencia e determinação dos interferentes endocrinos (IE) e produtos farmaceuticos e de higiene pessoal (PFHP) / Potable water quality in the Campinas region : occurrence and determination of endocrine disruptors (EDs) and pharmaceuticals and personal care products (PPCPs)

Ghiselli, Gislaine 13 December 2001 (has links)
Orientador: Wilson de Figueiredo Jardim / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Quimica / Made available in DSpace on 2018-08-07T20:01:49Z (GMT). No. of bitstreams: 1 Ghiselli_Gislaine_D.pdf: 7893135 bytes, checksum: 77abd572fbade3721ea074ed0616e34b (MD5) Previous issue date: 2006 / Doutorado / Quimica Analitica / Doutor em Quimica
98

Analýza organických látek přítomných v biouhlu / Analysis of organic substances present in biochar

Bača, Ondřej January 2021 (has links)
This master's thesis deals with the analysis of organic substances, which are present in biochar. Biochar contains a number of organic compounds, that can be toxic and also carcinogenic to living organisms. In order for biochar to be used to improve soil quality or to be used for other applications, its safety must be declared by European or international certifications. Relevant European and international standards have been created for the determination of organic substances, that could be present in biochar. The theoretical part of the thesis was focused on selected organic substances, the process of pyrolysis and thermochemolysis, biochar characterisation and the used analytical methods. The experimental part of the thesis consisted of extraction with toluene and after that the determination of concentration of the 38 polycyclic aromatic hydrocarbons was performed. Qualitative analysis was performed by two-dimensional gas chromatography. Biochar samples were also subjected to thermochemolysis method and then they were analysed on GC-MS again. In both analytical methods, a large number of substances from groups such as PAHs, carboxylic acids, amines, substituted naphthalenes etc. was found, as well as smaller number of eg. polychlorinated biphenyls.
99

Studium průniku vybraných degradačních produktů syntetických polymerů do životního prostředí / Study of the selected synthetic polymer degradation products penetration into enviromental compartments

Tobiášová, Tereza January 2008 (has links)
The subject of this thesis is the study of the degradation of polyurethanes in the weather conditions on the waste dumps and observation of the penetration of the potential degradation products into the environment.
100

Stanovení alkylderivátů rtuti ve vodním ekosystému / Determination of mercury alkylderivatives in water ecosystem

Doležalová, Jana January 2009 (has links)
Diploma thesis is oriented on the question of the fate and occurence of mercury and its derivatives in water ecosystems. At first, deep literature review will be worked out. At second, the optimal analytical procedure for the determination of mercury alkylderivatives in water ecosystem compartments will be proposed and verified. At third, real samples from selected water ecosystems will be taken and analyzed.

Page generated in 0.0873 seconds