• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 303
  • 7
  • 1
  • 1
  • Tagged with
  • 319
  • 319
  • 268
  • 268
  • 178
  • 130
  • 130
  • 110
  • 89
  • 84
  • 78
  • 78
  • 68
  • 67
  • 64
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
181

Microgeração solar fotovoltaica conectada à rede: análise da qualidade da energia / Solar grid-connected photovoltaic microgeneration: energy quality analysis

Santiago, Gregory Luid Souza 21 February 2017 (has links)
Submitted by Lara Oliveira (lara@ufersa.edu.br) on 2017-06-29T18:40:34Z No. of bitstreams: 1 GregoryLSS_DISSERT.pdf: 2365446 bytes, checksum: d4abe11e0270841ffc2cbf5442616e03 (MD5) / Rejected by Vanessa Christiane (referencia@ufersa.edu.br), reason: Corrigir referência. on 2017-07-03T12:21:23Z (GMT) / Submitted by Lara Oliveira (lara@ufersa.edu.br) on 2017-07-04T14:44:36Z No. of bitstreams: 1 GregoryLSS_DISSERT.pdf: 2365446 bytes, checksum: d4abe11e0270841ffc2cbf5442616e03 (MD5) / Approved for entry into archive by Vanessa Christiane (referencia@ufersa.edu.br) on 2017-07-04T16:49:00Z (GMT) No. of bitstreams: 1 GregoryLSS_DISSERT.pdf: 2365446 bytes, checksum: d4abe11e0270841ffc2cbf5442616e03 (MD5) / Approved for entry into archive by Vanessa Christiane (referencia@ufersa.edu.br) on 2017-07-04T16:58:35Z (GMT) No. of bitstreams: 1 GregoryLSS_DISSERT.pdf: 2365446 bytes, checksum: d4abe11e0270841ffc2cbf5442616e03 (MD5) / Made available in DSpace on 2017-07-04T16:58:47Z (GMT). No. of bitstreams: 1 GregoryLSS_DISSERT.pdf: 2365446 bytes, checksum: d4abe11e0270841ffc2cbf5442616e03 (MD5) Previous issue date: 2017-02-21 / Distributed photovoltaic systems currently have a great potential for growth, due to several factors that make it quite attractive, among them: tariff parity reached in the coming years in some countries, reduction of installation costs, government incentives, and sector regulation, among others. Since these are relatively new types of systems, many researches have been carried out to study the behavior of a distributed photovoltaic generation system connected to the distribution grid. In this sense, the main objective of this work is to analyze the impact generated in energy quality by the installation of a Grid-Connected Photovoltaic System (GCPV) installed in UFERSA, located in Mossoró/RN. Through the evaluation of the main parameters of energy quality generated by the GCPV, it was verified that the installation of a distributed photovoltaic system connected at low voltage causes small changes in some parameters, such as elevation in the steady state voltage, reduction of the power factor of the installation and increase in the value of the total harmonic distortion rate of current. In the work in question, all variations found did not exceed the limits established by the current regulations. It was also verified that the installation of the GCPV caused a daily reduction of up to 38% in the average active energy consumed, considering the phase in which the system is interconnected / Os sistemas fotovoltaicos distribuídos possuem atualmente um grande potencial de crescimento, devido a diversos fatores que o tornam bastante atraentes, dentre eles: paridade tarifária sendo alcançada nos próximos anos em alguns países, redução dos custos de instalação, incentivos governamentais, regulação do setor, entre outros. Por tratar-se de tipos de sistemas relativamente novos, muitas pesquisas têm sido desenvolvidas no intuito de estudar o comportamento de um sistema de geração fotovoltaica distribuída, conectado à rede elétrica de distribuição. Neste sentido, o presente trabalho tem como objetivo principal analisar o impacto gerado na qualidade de energia pela instalação de um Sistema Fotovoltaico Conectado à Rede (SFCR) instalado na UFERSA, localizada em Mossoró/RN. Através da avaliação dos principais parâmetros de qualidade de energia gerados pelo SFCR verificou-se que a instalação de um sistema fotovoltaico distribuído conectado em baixa tensão provoca pequenas alterações em alguns parâmetros, tais como: elevação na tensão de regime permanente, redução do fator de potência da instalação e acréscimo no valor da taxa de distorção harmônica total de corrente. No trabalho em questão, todas as variações constatadas não ultrapassaram os limites estabelecidos pelas normas vigentes. Constatou-se, ainda, que a instalação do SFCR provocou redução diária de até 38% na energia ativa média consumida, considerando a fase na qual o sistema está interconectado / 2017-06-29
182

Propagação de harmônicas produzidas por inversores fotovoltaicos e transformadores assimetricamente magnetizados na geração distribuída /

Fortes, Rárison Roberto Acácio January 2018 (has links)
Orientador: Luís Carlos Origa de Oliveira / Resumo: As profundas mudanças que os sistemas de distribuição de energia elétrica vêm experimentando, devido à crescente penetração de unidades de Geração Distribuída (GD), têm resultado, inevitavelmente, na efetiva ruptura da forma tradicional de controlar e operar o sistema elétrico. A conexão em larga escala de unidades de GD impõe às distribuidoras de energia uma série de desafios técnicos, econômicos e regulatórios, necessários para preservar a continuidade e o nível de Qualidade da Energia Elétrica (QEE) na rede. Além dos benefícios que justificam o investimento, os sistemas de GD contribuem com alguns impactos negativos para o sistema elétrico, entre eles, destacam-se aqui a geração de harmônicas e a injeção de corrente contínua (CC) na rede, em regime permanente, e seus efeitos sobre os transformadores de potência. O incremento de uma componente de fluxo CC em seu enrolamento secundário altera o ponto de operação natural e eficiente do transformador, trazendo prejuízo não só à sua vida útil, mas também à sua funcionalidade na rede. Esta condição favorece a geração e propagação de harmônicas adicionais no sistema alimentador, afetando negativamente o sistema elétrico, sendo esta análise uma contribuição original deste trabalho. Neste sentido, considera-se com grande relevância o estudo de comportamento dos equipamentos projetados para operar essencialmente com sinais em corrente alternada (CA) e que passam a ser submetidos, simultaneamente, a excitações com corrente contínua. ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The deep changes that electric power distribution systems have been experiencing due to the increasing number of Distributed Generation (GD) units, have inevitably resulted in the effective rupture of the traditional way of controlling and operating the electrical system. The large-scale connection of GD units imposes on energy utilities many technical, economic and regulatory challenges necessary to preserve the continuity and the Electric Power Quality (EPQ) level on the grid. In addition to the benefits that justify the investment, GD systems have some negative impacts to the electrical system, among them, the harmonic generation and Direct Current (DC) injection on the grid, and its effects in the power transformers. The increase of a DC flow component in the secondary winding changes the standard and efficient operational point of the transformer, causing damage not only to its lifespan but also to its functionality on the grid. This condition favors the additional harmonics generation and propagation in the feeder system, adversely affecting the electrical system, being this analysis an original contribution of this work. In this way of thinking, it is considered with great relevance the study of the equipment behavior designed to operate essentially with signals in alternating current (AC) and simultaneously subjected to excitations with direct current (DC). Whereas the objective of analyzing not only the effect but also the cause of the double excitation, this thesis ... (Complete abstract click electronic access below) / Doutor
183

Metodologia para avaliação do risco de ilhamento não intencional de geradores eólicos distribuídos

Vieira, Thiago Correia January 2014 (has links)
Orientador: Prof. Dr. Ahda Pionkoski Grilo Pavani / Dissertação (mestrado) - Universidade Federal do ABC, Programa de Pós-Graduação em Engenharia Elétrica, 2014. / O ilhamento não intencional ocorre quando a proteção não é capaz de detectar a operação ilhada de parte do sistema de distribuição. Estas falhas ocorrem para condições específicas de geração e carga do subsistema ilhado, nas quais as variações de tensão e frequência após o ilhamento não são suficientes para sensibilizar a proteção. Neste trabalho é apresentada uma metodologia para o cálculo do índice de risco de ilhamento não intencional de geradores eólicos distribuídos, considerando que estes geradores empregam relés de sub/sobrefrequência e sub/sobretensão para proteção anti-ilhamento. A metodologia desenvolvida utiliza curvas características de velocidade de vento de uma região e curvas de carga para identificar as possíveis condições de operação do sistema. Com a aplicação da metodologia proposta é possível avaliar o risco da proteção anti-ilhamento baseada em relés de sub/sobretensão e sub/sobrefrequência não detectar o ilhamento. Como resultado, a concessionária poderá avaliar se somente a proteção anti-ilhamento baseada nestes relés é suficiente, ou se devido ao alto risco de não detecção esquemas mais sofisticados devem ser empregados. / The unintentional islanding occurs when the protection is not able to detect the islanded part of the distribution system operation. These failures occur for specific conditions of generation and load islanded subsystem in which the variations of voltage and frequency after islanding are not sufficient to sensitize protection. In this work a methodology to calculate the unintentional islanding risk index of distributed wind generators is presented, considering that these generators employ under/overfrequency and under/overvoltage protection relays for anti-islanding. The methodology uses the characteristic curves of wind speed in a region and load curves to identify the possible operating conditions of the system. Proposed methodology can assess the risk of anti-islanding protection based on under/overvoltage and under/overfrequency relays not detect islanding condition. As a result, the utility can only assess whether the anti-islanding protection based on these relays is sufficient, or if due to the high risk of failure to detect more sophisticated schemes must be employed.
184

Metodologia para proteção adaptativa de linhas de distribuição na presença de geradores síncronos distribuídos

Ferreira, Roberta Rosa January 2015 (has links)
Orientadora: Profa. Dra. Ahda Pionkoski Grilo Pavani / Dissertação (mestrado) - Universidade Federal do ABC, Programa de Pós-Graduação em Engenharia Elétrica, 2015. / A operação de parte da rede de distribuição de forma ilhada alimentada por geradores distribuídos aumenta os índices de confiabilidade do sistema, caso de problemas com a conexão com a rede principal reduz o tempo de indisponibilidade do fornecimento de energia elétrica para um conjunto de cargas. Os geradores síncronos distribuídos por apresentarem regulador de velocidade e controle de excitação podem mais facilmente operar no modo ilhado. Um dos grandes desafios da operação ilhada, no entanto, é a redução drástica dos níveis de curto-circuito quando a rede passa a operar de forma ilhada, comprometendo as funções de proteção dos relés de sobrecorrente. Com isso, para a operação de forma segura de uma rede ilhada é necessário alterar o ajuste da proteção dos relés de sobrecorrente. Os relés digitais apresentam a possibilidade de armazenar dois ou mais ajustes distintos de proteção, e a seleção do ajuste a ser usado pode ser realizada via um sinal externo. Neste contexto, o objetivo desta dissertação é apresentar um método capaz de identificar o estado de conexão da rede com a subestação principal e, em caso de alteração deste estado, enviar um sinal para o relé de proteção para a seleção do ajuste adequado. O método proposto não depende de comunicação e baseia-se em um dispositivo simples composto basicamente por um tiristor, que pode ser instalado próximo ao relé. O dispositivo foi modelado no MatLab e utilizado em simulações computacionais de uma rede de distribuição para validar a metodologia proposta. A rede de distribuição simulada possui capacidade de operar de forma ilhada alimentada por dois geradores síncronos distribuídos. O método proposto apresentou bom desempenho e foi capaz de identificar a condição de operação do sistema e selecionar o ajuste da proteção de forma adequada. / The capacity of part of the system to keep an autonomous operation supplied by distributed generators improves the network reliability indices, since, in case of the loss of the connection with the utility grid, it reduces the frequency and duration of interruptions for the customers. Considering that distributed synchronous generators usually have excitation system and speed regulator, they can easily control the voltage and frequency of the system and operate in the islanded mode. However, one of the challenges of islanded operation is the drastically decrease of fault current level when the system is operating in the islanded mode compared to the main system connected condition. So, to ensure a safe grid operation the overcurrent protection settings should be changed. The microprocessor-based overcurrent relay have more than one setting group and thus have the possibility to change the tripping characteristics during the operation as a function of an input signal. In this context, the objective of this thesis is to present a method capable of identifying the grid state and send a signal to the overcurrent relay in order to change the overcurrent settings. The proposed method doesn¿t depend on the communication systems for the relays, and it is based on a simple device composed by one tyristor, which can be installed next to the relay. The device was modeled in MatLab and used in computational simulations considering a typical distribution system to validate the proposed method. The distribution grid used has the capacity of operating in islanded mode or connected to the utility grid mode. The proposed method has presented a good performance and it was able to identify the operation condition in order to select the suited protection setting.
185

Planejamento ótimo de geração distribuída renovável em redes de distribuição ativas para reduzir emissões de gases de efeito estufa

Olivas, José Luis Mejia January 2015 (has links)
Orientador: Prof. Dr. Haroldo de Faria Junior / This dissertation presents a planning methodology to reduce emissions of greenhouse gases, applicable in active distribution networks, using renewable distributed generation and new control strategies. The studies done had as main objective the development of a methodology, applicable in distribution networks with feature of generation and variable load, to reduce emissions of greenhouse gases derived from electricity generation activities. The developed optimization methodology was based on the formulation of a AC optimal power flow (OPF) problem, integrating the new strategy of active networks management (ANM) that contains schemes such as coordinated voltage control (CVC), adaptive power factor control (PFC) and energy curtailment (EC). To solve the optimization problem, the modeling and optimization software AIMMS was used. The results show that significant reduction of greenhouse gas emissions can be achieved through the connection of renewable distributed generation in active distribution networks compared to passive networks. / Dissertação (mestrado) - Universidade Federal do ABC, Programa de Pós-Graduação em Engenharia Elétrica, 2015. / Nesta dissertação apresenta-se uma metodologia de planejamento para redução de emissões de gases de efeito estufa, aplicável em redes de distribuição ativas, usando geração distribuída renovável e novas estratégias de controle. Os estudos feitos tiveram como objetivo principal o desenvolvimento de uma metodologia, aplicável em redes de distribuição com característica de geração e carga variável, para reduzir emissões de gases de efeito estufa derivados das atividades de geração de energia elétrica. A metodologia de otimização desenvolvida foi baseada na formulação de um problema de fluxo de potência ótimo (FPO) AC multi-período integrando a nova estratégia de gestão de redes ativas (GRA), que contém esquemas como o controle de tensão coordenado (CVC), controle de fator de potência adaptativo (CFPA) e redução de energia (RE). Para resolver o problema de otimização, foi utilizado o programa computacional de modelagem e otimização AIMMS. Os resultados mostram que reduções significativas de emissões de gases de efeito estufa podem ser alcançadas mediante a ligação de geração distribuída renovável em redes de distribuição ativas em comparação com redes passivas.
186

Distorções harmônicas produzidas por inversores de geração distribuída fotovoltaica em condição de ressonância paralela / Harmonic distortion produced by inverters photovoltaic distributed generation in parallel resonance condition

Fortes, Rárison Roberto Acácio [UNESP] 12 March 2016 (has links)
Submitted by RARISON ROBERTO ACACIO FORTES null (rarisonfortes@yahool.com) on 2016-05-05T14:43:06Z No. of bitstreams: 1 RFortes.pdf: 3576878 bytes, checksum: 1f31f85eeeb5bf64f3b8b9781d51941c (MD5) / Approved for entry into archive by Felipe Augusto Arakaki (arakaki@reitoria.unesp.br) on 2016-05-09T13:45:49Z (GMT) No. of bitstreams: 1 fortes_rra_me_ilha.pdf: 3576878 bytes, checksum: 1f31f85eeeb5bf64f3b8b9781d51941c (MD5) / Made available in DSpace on 2016-05-09T13:45:49Z (GMT). No. of bitstreams: 1 fortes_rra_me_ilha.pdf: 3576878 bytes, checksum: 1f31f85eeeb5bf64f3b8b9781d51941c (MD5) Previous issue date: 2016-03-12 / Fundação de Amparo à Pesquisa do Estado do Acre (FAPAC) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Como os sistemas de energia têm sido tradicionalmente projetados para produção centralizada, a penetração de sistemas de geração distribuída na rede tem causado mudança nesse perfil, criando novos desafios operacionais que se fazem importantes para a reestruturação dos sistemas tradicionais. No entanto, este novo cenário do sistema elétrico, introduzido pela resolução 482/2012 da Agência Nacional de Energia Elétrica – ANEEL, trouxe às distribuidoras de energia um novo panorama para as atividades de operação e manutenção de suas redes e ativos, principalmente devido à bidirecionalidade do fluxo de potência na rede, originado pela conexão de sistemas de geração distribuída. Os impactos técnicos devem ser previstos e analisados, sobretudo em redes de distribuição, para garantir os padrões mínimos de qualidade da energia no ponto de consumo e evitar o comprometimento das cargas alimentadas. Dentre os impactos, destaca-se o efeito sobre os bancos de capacitores devido à injeção de distorções harmônica produzida pelos inversores de sistemas fotovoltaicos, que sob certas condições, produzem conteúdo harmônico com nível acima do limite normatizado, podendo excitar uma condição prévia de ressonância no barramento. Neste contexto, esta dissertação tem como principal objetivo analisar o comportamento do sistema elétrico em condição de ressonância paralela e avaliar o grau de comprometimento dos bancos de capacitores instalados no sistema de distribuição com presença de frequências harmônicas e sugerir rotinas técnicas para evitar sua operação contingenciada. / As energy systems have been traditionally projected for centralized production, the penetration of distributed generation systems have caused a change in this profile, creating new operational challenges that are important for traditional systems restructuring. However, this new electrical system scenario, introduced by resolution 482/2012 of Brazilian Electricity Regulatory Agency – ANEEL, brought to energy distributors a new view to the operational and maintenance activities of their nets and actives, specially due to the net power flow bidirectionality, created by the distributed generation systems connection. Technical impacts must be estimated and analyzed, specially in distribution nets, to ensure minimum energy quality standards in the consumption point and avoid fed charges commitment. Among the impacts stands out the capacitor bench effects due to harmonic distortions injection produced by photovoltaic systems inverters, that under some conditions, produce harmonic content over the regulated limit, being able to excite a preview condition of resonance in the bus. In this context, this essay has the main objective to analyze the electrical system behavior in parallel resonance condition and evaluate the degree of commitment of the capacitor bench installed in the distribution system with harmonic frequencies and suggest technical routines to avoid the contingent operation. / FAPAC: 6068-14-0000093
187

Análise da viabilidade técnica da operação de sistemas com geração distribuída no modo ilhado intencional / Analysis of the technical feasibility of the operation of systems with distributed generation in the intentional islanded mode

Deifelt, Samuel Vanderlei 22 March 2016 (has links)
The increasing demand for energy, coupled with the difficulties inherent in the implementation of large generation projects, significantly increased the use of energy resources from renewable energy sources, in order to better meet the energy market. Recent research shows that there are several benefits of using the Distributed Generation in relation to large enterprises Centralized Generation. In this sense, this work shows the results of studies conducted in order to verify the feasibility of taking advantage of the Distributed Generation to meet the remaining local loads in any power shortages Distributor. This operation is called Intentional Islanded Operation. In order to implement the intentional islanding operation of Distributed Generation, it is necessary to carry out specific studies to meet the levels of quality and continuity established by regulations and to ensure the safety of the electrical system. Thus, this work presents an analysis of the technical feasibility of intentional islanded operation of distributed generators, given the restrictions imposed resulting from Power Flow studies, Transient Stability and Short Circuit. / O crescente aumento da demanda de energia, associado às dificuldades inerentes à implantação de empreendimentos de geração de grande porte, aumentou significativamente o aproveitamento dos recursos energéticos a partir de fontes de energia renováveis, visando um melhor atendimento do mercado de energia. Pesquisas recentes mostram que há diversas vantagens em se utilizar a Geração Distribuída em relação aos grandes empreendimentos de Geração Centralizada. Neste sentido, esta dissertação mostra os resultados de estudos realizados com o objetivo de verificar a viabilidade em se aproveitar as Gerações Distribuídas para o atendimento das cargas locais remanescentes, em eventuais faltas de energia da Distribuidora. Esta operação é denominada de Operação Ilhada Intencional. Para que a operação ilhada de Geradores Distribuídos possa ser admitida, estudos específicos devem ser realizados, a fim de que os níveis de qualidade e continuidade exigidos pelos órgãos reguladores sejam atendidos e que a segurança do sistema elétrico seja preservada. Desta forma, esta dissertação apresenta uma análise da viabilidade técnica da operação ilhada intencional de Geradores Distribuídos, considerando as restrições resultantes impostas a partir de estudos de Fluxo de Potência, Estabilidade Transitória e Curto-Circuito.
188

Seleção de sistemas de geração de energia elétrica a partir de resíduos sólidos urbanos: uma abordagem com a lógica difusa

Barin, Alexandre 19 June 2012 (has links)
Conselho Nacional de Desenvolvimento Científico e Tecnológico / Sustainability is becoming a major driving force in energy policy, leading to the development of different strategies and projects. Many of these strategies are related to the application of novel methodologies for selecting Renewable Energy Systems (RES) and energy storage systems. Electrical generation with biogas from municipal solid waste (MSW) is one of the main alternatives to concern all the conceptions of sustainability - social, economic and environmental constrains. The complexity of sustainability and energy planning makes the multicriteria analysis a valuable tool for the decision making process. The use of an effective methodology for RES selection a decision making process is essential to guarantee the adequate energy management of the biogas and the MSW landfill. This methodology must be able to balance positive and negative aspects, achieving an overall solution that best satisfies the management needs. It is essential to deal with several parameters and concern the decision maker (DM) interaction over the decision making process. By applying the DM preferences into the development of the methodology, it is possible to corroborate the methodology outcome. The presented thesis will therefore develop a novel methodology for selection of RES fuelled by biogas from MSW landfills. This methodology taking as basis fuzzy multi-rules and multi-sets to provide an accurate analysis of conflicting aspects - operational, economic, environmental, social, etc. These aspects are taken into account for each study case according to different perspectives adopted by the DMs. The novel arrangements developed in this work are the creation of a previous classification of the priority criteria, the application of meta-rules and how to structure the fuzzy rules construction. The proposed arrangements have the purpose of easing the understanding of the methodology, as well as improving the DM interaction over the decision making process achieving in this way a better solution. This work presents the application of the novel decision making process to select the most appropriate energy source fuelled by biogas from MSW, considering the Caturrita II landfill located at Santa Maria City, Brazil. In conclusion, it is important to emphasize that the novel software may be used in any energy system selection, for supplying or storage, according to the analysis of several criteria and perspectives for each regional circumstances, as well as particular management needs.. / A busca pelo desenvolvimento sustentável, em âmbitos sociais e ambientais, é um fator de extrema importância que incentiva a elaboração de várias pesquisas e projetos, como por exemplo, à aplicação de técnicas de gerenciamento e seleção de fontes alternativas renováveis de geração de energia. Dentre estas fontes, o aproveitamento energético do biogás resultante da decomposição de resíduos sólidos urbanos é um dos meios que propicia um desenvolvimento sustentável de forma mais completa. Para o devido aproveitamento de fontes alternativas renováveis, como a geração de energia elétrica e térmica a partir de resíduos sólidos urbanos, deve-se tomar como base métodos multicriteriais, considerando a existência de uma série de critérios para atender necessidades e interesses diversos quando se deseja selecionar tecnologias de geração e armazenamento de energia. A partir da utilização de métodos de ajuda a decisão é possível incorporar de forma clara as preferências dos agentes de decisão, obtendo como resposta final uma solução mais satisfatória e que pode ser corroborada através de validações heurísticas discussões dos resultados junto aos agentes de decisão. Mediante estes argumentos, o presente trabalho tem a finalidade de desenvolver uma metodologia de apoio a decisão para a seleção de sistemas para geração de energia elétrica com biogás proveniente de resíduos sólidos urbanos, avaliando devidamente cada processo decisório de acordo com aspectos econômicos, operacionais, ambientais e sociais. Para o alcance deste objetivo fez se uso da lógica difusa baseada em regras e conjuntos fuzzy aplicados sobre diversos critérios, avaliando diferentes perspectivas. Os aperfeiçoamentos mais importantes apresentados na elaboração desta tese se referem à criação de uma etapa de relevância prévia aos critérios em análise, criação e seleção de meta-regras e forma de apresentação e construção de tais regras, facilitando o entendimento dos agentes de decisão para a avaliação do processo decisório e propiciando uma maior participação dos mesmos para obtenção de um resultado mais satisfatório. É possível observar ainda que os aperfeiçoamentos desenvolvidos permitiram a devida construção e averiguação das modelagens construídas. No estudo de caso principal aterro sanitário Caturrita II localizado na cidade de Santa Maria é verificada a aplicabilidade da metodologia de ajuda a decisão desenvolvida visando a seleção da fonte de geração de energia elétrica mais apropriada a ser utilizada no aterro em questão. Por fim, deve-se enfatizar que a partir dos aperfeiçoamentos alcançados durante o desenvolvimento desta tese, foi possível construir uma metodologia de ajuda a decisão genérica que pode ser aplicada não somente na seleção de sistemas de geração de energia em aterros, mas também na seleção de quaisquer sistemas de geração e armazenamento de energia, desde que todos os aspectos envolvidos no processo decisório sejam devidamente incorporados no problema em questão.
189

Novos métodos de estimação de estado multi-área com potencial aplicação em redes elétricas inteligentes / New methods for multi-area state estimation with potential application in the smart grid

Milbradt, Rafael Gressler 06 March 2015 (has links)
The smart grid will enable a revolution in the way we manage and relates to the distribution networks through intelligent applications. For many of these applications, it is understood that one of the primary activities to provide real time operation is to be aware of the electric state of the network by monitoring and using remote measurements. This thesis addresses the topic of state estimation proposing the use of methods that best fit the requirements of smart distribution networks. In a first moment it is understood that the monitoring will not be satisfactorily comprehensive, and then there will need to merge real measures with not real measures obtained through historical data and direct methods such as calculating the power flow. Another important requirement of these methods is to combine great complexity and large number of buses of the distribution network to a satisfactory response time that allows real-time monitoring. Thus this thesis uses an approach that enables multiprocessing of algorithms like Power Flow and State Estimation in order to get faster response times in multiprocessor environments, which now are quite common. In the case of State Estimator has been proposed a Multi-area estimator associated to an algorithm for massive division of the networks which allows to drastically reduce the complexity of the algorithm without compromising the accuracy of the estimator solution. Nevertheless, other concepts related to state estimation, but adapted to the context of smart grids are also addressed as the detection of errors in measurements, topology errors and to the ideal location of meters, which may have important influence on the accuracy of the obtained result. The ASW software - Analysis of Distribution Systems Web was developed to implement the proposed methodologies. The software is a totally working prototype, already tested on a real distribution networks and have demonstrated good results and potential for managing a distribution system in an smart way. / As redes elétricas inteligentes permitirão uma revolução na forma como se gerencia e se relaciona com as redes de distribuição, através de aplicações inteligentes. Para diversas destas aplicações, entende-se que uma das atividades primordiais para proporcionar a operação em tempo real é ter conhecimento do estado elétrico da rede através do monitoramento e do uso de medidas remotas. A presente tese aborda o tema de estimação de estado propondo o uso de métodos que melhor se adaptam aos requisitos das redes de distribuição inteligentes. Num primeiro momento entende-se que o monitoramento não será satisfatoriamente abrangente, então haverá a necessidade de mesclar medidas remotas reais com outras pseudo-medidas obtidas através de dados históricos e métodos diretos como o cálculo do Fluxo de Potência. Outro requisito importante destes métodos é conseguir conciliar a grande complexidade e o elevado número de nós das redes de distribuição a um tempo de resposta satisfatório que permita o monitoramento em tempo real. Desta forma a presente tese utiliza uma abordagem que permite o multiprocessamento dos algoritmos de Fluxo de Potência e Estimação de Estado de forma a obter um menor tempo de resposta em ambientes multiprocessados, que são bastante comuns atualmente. No caso do Estimador de Estados, foi proposto um estimador multi-área associado a um algoritmo de divisão maciça das redes, que permite reduzir drasticamente a complexidade do algoritmo sem comprometer a precisão da solução. Todavia, outros conceitos relacionados à estimação de estado, porém adaptados ao contexto de redes de distribuição inteligentes também são abordados como a detecção de erros em medidas, erros de topologia e a localização ideal de medidores, os quais podem ter importante influência na precisão do resultado obtido. O software ASW Análise de Sistemas de Distribuição Web foi desenvolvido para implementação das metodologias propostas. O Software ainda se encontra sob a forma de um protótipo, contudo já se apresenta funcional em redes de distribuição reais e demonstrando bons resultados e potencialidades para o gerenciamento de um sistema de distribuição inteligente.
190

Metodologia para despacho de fontes de GD a biogás em redes de distribuição utilizando lógica Fuzzy / Effective connection of distributed generation sources on distribution networks using Fuzzy sets and rules.

Martins, Luiz Fernando Guarenti 19 March 2012 (has links)
The aim of this work is determine the most appropriated period for connection of a particular generation source fueled by biogas on a distribution network. The biogas is produced through anaerobic reactions that occur in the municipal solid waste deposited at the landfill specific landfill in analysis. The Minas do Leão landfill is taken as study case, predicting the connection of this generation source on a distribution network supported by the State Company of Electrical Energy (CEEE). The Biogas® software was used to estimate the amount of methane generated in the landfill and to determine the landfill life cycle. By using that information it is possible to plot the power electrical generation curve in MW. The choice for the Biogas® software is justified because this tool is free software developed between the federal government environment state administration and the CETESB (Technology Company of Environmental Sanitation of the State of Sao Paulo). After that, the PSL®DMS software was used to simulate the main electrical characteristics of the network in analysis. These simulations provided the data for evaluating the quantitative parameters voltage levels, power losses and load current. A group of decision makers were selected for establishing scores applied to the qualitative parameter evaluation - availability of ancillary services support. After the definition of the quantitative and qualitative parameters a multiobjective methodology was developed. In the first step of the methodology are applied pertinent fuzzy functions trapezoidal variables that consider electrical characteristics of the network and also the voltage levels defined in the PRODIST (Proceedings of Electric Energy Distribution on Electrical National System). The second part is associated with the decision makers estimative, in which the decision maker presents some scores for each type of ancillary service in analysis, according to the specific moment when this ancillary service will be supported. For these evaluations are considered the demand curve of the feeder where the distributed source will be connected. The methodology was then applied for selecting and ranking the most appropriated period to connect the distributed generation source on the distribution network. The definition of the ranking is the outcome of the data evaluation according to the final priorities quantitative and qualitative analysis. / Este trabalho tem a finalidade de definir o período do dia para o despacho de uma fonte alternativa de geração distribuída de energia elétrica (GD), utilizando como combustível o biogás proveniente de reações anaeróbias que ocorrem em resíduos sólidos urbanos (RSU) depositados em células do Aterro Sanitário de Recreio no município de Minas do Leão à rede da Companhia Estadual de Distribuição de Energia Elétrica (CEEE-D). Inicialmente foi utilizado o software Biogás® para estimar a vazão de metano (gás em maior porcentagem no biogás) e avaliar a potência que este gás disponibiliza para ser gerada em qualquer aterro em função do tempo de vida útil do mesmo. Este software foi escolhido para ser utilizado neste trabalho por ser uma ferramenta livre e desenvolvida no Brasil pelo convênio entre a Secretaria de Estado do Meio Ambiente e da Companhia de Tecnologia de Saneamento Ambiental do Estado de São Paulo (CETESB) com o Governo Federal, por meio do Ministério da Ciência e Tecnologia. Esta recuperação energética do metano tem potencialidade de servir como combustível para alimentar um ou mais conjuntos de motores geradores Ciclo Otto adaptados para biogás. Após a estimativa da vazão de biogás e da potência que pode ser gerada no aterro, partiu-se para a execução de simulações com as grandezas elétricas do alimentador. Neste trabalho as simulações das grandezas elétricas foram obtidas com o uso do software PSL®DMS, ferramenta utilizado pelos técnicos da CEEE-D para análise da do fluxo de carga de sistemas de distribuição, e serão utilizadas como critérios denominados de quantitativos. Para determinar o momento ideal para a conexão da GD à rede de distribuição da concessionária, foi utilizado um método de apoio à decisão. Este método considera critérios quantitativos e qualitativos definidos pelos Especialistas ou Agentes de Decisão (AD), no caso, técnicos da concessionária de energia elétrica que avaliam em conjunto estes dados. Os critérios qualitativos são baseados na possibilidade de incrementos de serviços subsidiários ao sistema de distribuição de energia elétrica, denominados de Serviços Ancilares (SA). A definição da prioridade dos valores dos critérios quantitativos (grandezas elétricas da rede de distribuição) é baseada na análise de funções trapezoidais que relacionam as grandezas elétricas a valores e percentuais definidos pelo PRODIST e pelos AD. Já para os critérios qualitativos, a análise ocorre em função de uma metodologia denominada de Estimativa de Especialistas, em que os mesmos aplicam notas ao tipo de SA que será aplicado e ao momento de sua aplicação em relação às características da curva de demanda do AL. A definição do ranking dos melhores horários do dia para despacho da GD ao AL é consequência da avaliação dos valores estabelecidos para as prioridades finais dos critérios quantitativos e qualitativos.

Page generated in 0.0643 seconds