• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 12
  • 2
  • 1
  • 1
  • Tagged with
  • 16
  • 16
  • 6
  • 6
  • 5
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Estudo, otimização e aplicação de microondas acoplado ao processo oxidativo avançado H2O2/UV na degradação da tartrazina / Study, optimization, and application of microwaves coupled to the H2O2/UV advanced oxidation process in the degradation of tartrazine

Parolin, Fernanda 11 August 2011 (has links)
Os corantes azo são amplamente utilizados em muitas indústrias, entre elas as alimentícias, farmacêuticas e têxteis. Quando essas moléculas estão presentes no efluente industrial tornam o seu tratamento, que na maioria dos casos é biológico, difícil. Suas complexas estruturas são altamente estáveis e a presença de grupos sulfônicos (-SO3H) torna o corante ácido e altamente solúvel em água. Um exemplo deste tipo de corante é a tartrazina que pode causar efeitos adversos para a saúde humana, como alergia. Desde o início dos anos 70, quando os Processos Oxidativos Avançados (POAs) foram reconhecidos por sua capacidade de degradar poluentes em meio aquoso, houve um aumento significativo nas pesquisas por duas razões: a diversidade de tecnologias envolvidas e a grande variedade de efluentes que os POAs são capazes de tratar. A fotoquímica assistida por microondas (MO) consiste na combinação de dois tipos distintos de radiação eletromagnética, microondas e UV/VIS, na ativação de reações químicas. Frequentemente está associada ao uso de uma lâmpada de descarga sem eletrodo (LDE) que gera radiação ultravioleta (UV) sob a influência de um campo de microondas. O presente trabalho tem como objetivo tratar uma solução de tartrazina (25 mg L-1) utilizando o processo H2O2/UV/MO e otimizando-o a fim de se obter a maior degradação com a utilização da menor quantidade de oxidante possível. Para tanto, elaborou-se um planejamento fatorial com a finalidade de observar o comportamento das variáveis independentes pH e concentração inicial de peróxido de hidrogênio no processo. A partir dos resultados, elaborou-se um planejamento composto central a fim de se ajustar um modelo polinomial aos dados obtidos. A condição ótima de tratamento para as variáveis independentes foi: pH = 2,6 e [H2O2] = 2 × 10-3 mol L-1. A variável-resposta observada foi a remoção de cor (por meio da integração da área dos espectros na região do visível). A cinética obtida para o processo H2O2/UV/MO foi de ordem zero, com k = 3,9 × 10-2 u.a.-1 min-1 e, aproximadamente, 92% de descoramento em 24 minutos. A biodegradabilidade (DBO5/DQO) e a análise de carbono orgânico total (COT) não apresentaram variação significativa. No entanto, pôde-se observar, através da CE50, que o processo H2O2/UV/MO reduziu a fitotoxicidade da solução de tartrazina, indicando a possível formação de intermediários de degradação menos tóxicos que a molécula original. A avaliação do efeito das microondas foi feita pelo estudo da degradação da solução de tartrazina através dos processos H2O2, MO, H2O2/MO e UV/MO, sendo que o descoramento não passou de 20%, indicando que as MO influenciam no processo H2O2/UV devido ao possível sinergismo com a radiação UV e também pelos possíveis efeitos térmicos e não térmicos exercidos por essa radiação. / Azo dyes are extensively used in many industries such as food, drugs, and textiles ones. When these molecules are present in the industrial wastewaters, they make their treatment, which is in most cases a biological one, quite difficult. Their complex structures are very stable and the presence of sulfonic groups (-SO3H) makes the azo dyes acid and highly water-soluble. Tartrazine is an example of these dyes and can cause adverse effects to human health, like allergy. Since the early 70\'s, when Advanced Oxidation Processes (AOPs) were recognized by their capacity of degrading pollutants in aqueous media, there was a significant increase in research and for two reasons: the diversity of technologies involved and the many kinds of wastewaters that AOP can treat. The microwave-assisted photochemistry is the combination of two distinct types of electromagnetic radiations: microwave (MW) and UV/VIS. It is often associated with the use of an electrodeless discharge lamp (EDL), which generates ultraviolet (UV) radiation when placed in a microwave field. The aim of the present work is to treat a solution of tartrazine (25 mg L-1) by the H2O2/UV/MW process, as well as optimizing the process in order to obtain degradation with the use of the lowest possible amount of oxidant. For that purpose, a factorial design was performed to observe the effect of the independent variables pH and hydrogen peroxide concentration. With the results obtained, a composite central design was performed to fit a polynomial model to the data. The optimum treatment condition was: pH = 2.6 and [H2O2] = 2 × 10-3 mol L-1. The response variable was color removal (measured by the area under the spectra obtained in the visible region). The decolorization kinetics of the H2O2/UV/MW process followed a zero order model, with k = 3,9 × 10-2 u.a.-1 min-1 and color removal achieved 92% in 24 minutes. The biodegradability (BOD5/COD) ratio and total organic carbon (TOC) analyses showed no significant changes. However, through the CE50 maybe observed that the H2O2/UV/MW process reduced the toxicity of the tartrazine solution, indicating the possible formation of less toxic intermediates than the original molecule. The microwaves effect was assessed in a degradation study of the tartrazine solution by H2O2, MW, H2O2/MW, and UV/MW processes, and the decolorization did not exceed 20%, indicating that the MW influence the H2O2/UV process because of the possible synergism with the UV radiation and thermal and non-thermal effects exerted by the radiation.
2

Estudo da otimização do processo H2O2/UV para o descoramento de um efluente de indústria têxtil / Optimization study of the H2O2/UV process for decolorization of a textile industry wastewater

Franco, Maraissa Silva 23 April 2010 (has links)
Os efluentes gerados pelas indústrias têxteis possuem como características elevada DQO, alta concentração de matéria orgânica não-biodegradável e intensa coloração, já que em média 12% do total de corantes utilizados são perdidos durante a produção. Os azo-corantes são os mais utilizados por possuírem uma alta aderência ao tecido, resistência à luz solar e a processos químicos. Estes corantes possuem como agravante o fato de serem quimicamente resistentes aos métodos de tratamentos biológicos convencionais. Os Processos Oxidativos Avançados (POA) têm sido estudados como uma alternativa promissora para o tratamento de substâncias tóxicas, refratárias e não-biodegradáveis. O presente trabalho tem como objetivo tratar um efluente de uma indústria têxtil utilizando o processo H2O2/UV para o descoramento dos corantes da família Remazol presentes, otimizando o processo a fim de se obter um efluente com características que facilitem o tratamento biológico. Para tanto, elaborou-se um planejamento experimental, com a finalidade de se estimar os efeitos das variáveis independentes pH, temperatura e concentração inicial de peróxido de hidrogênio. Em seguida, foi possível ajustar-se um modelo polinomial aos dados obtidos. A condição ótima de tratamento para as variáveis independentes foi: pH=12,3; temperatura = 52&deg;C e [H2O2] = 3,1 × 10-4 mol L-1. As variáveis-resposta observadas foram a remoção de cor (por meio da integração da área dos espectros na região do visível) e a concentração de peróxido de hidrogênio residual (método do vanadato de amônio). Para o efluente tratado com H2O2/UV, obteve-se uma remoção de cor de aproximadamente 80%, e para a fotólise direta obteve-se um valor de aproximadamente 75%, ambas com duas horas de irradiação. Para o processo H2O2/UV obteve-se uma cinética de primeira ordem, com constante de velocidade igual a (1,5 &plusmn; 0,36) × 10-2 min-1; para a fotólise, obteve-se uma cinética de segunda ordem com k = (2,3 &plusmn; 0,36) × 10-2 u.a.-1 min-1. A razão DQO/DBO não apresentou variação significativa para ambos os processos, mantendo o efluente dentro da faixa 5,0 < DQO/DBO > 2,5. A análise de carbono total foi concordante com os ensaios de DQO, não havendo mudanças significativas. No entanto, pôde-se observar, por meio de análises cromatográficas, que o processo H2O2/UV, aparentemente, foi responsável por uma maior degradação dos compostos presentes no efluente. / The wastewaters generated by the textile industry are known for their high COD, high concentration of non-biodegradable organic matter, and strong color, once approximately 12% of the dyes are lost during production. Azo dyes are the most used due to their high adherence to the fabrics, resistance to sunlight and to chemical processes. Those dyes have also the drawback of being resistant to conventional biological methods. Advanced Oxidation Processes (AOP) have been studied as a promising alternative for treating toxic, refractory, and non-biodegradable pollutants. The present work is aimed at treating the wastewater of a textile industry by the H2O2/UV process in order to remove the color due to the Remazol dyes present, as well as optimizing the process in order to obtain a wastewater easier to be biologically treated. For that purpose, an experimental design was performed to assess the effects of independent variables pH, temperature, and hydrogen peroxide concentration. Next, a polynomial model was fit to the obtained data. The optimum treatment condition was: pH = 12.3; temperature = 52&deg;C, and [H2O2] = 3.1 × 10-4 mol L-1. The response variables were color removal (measured by the area under the spectra obtained in the visible region) and the residual concentrations of H2O2 (vanadate method). Color removals of approximately 80 and 75% were achieved, for H2O2/UV and direct photolysis, respectively, both after two hours of irradiation. The decolorization kinetics of the H2O2/UV process followed a first order model, with a constant (k) of (1.5 &plusmn; 0.36) × 10-2 min-1, while the effluent treated with the direct photolysis showed a second order behavior, with k = (2.3 &plusmn; 0.36) × 10-2 u.a.-1 min-1. The COD/BOD ratio remained practically unchanged for both process, in the range of 5.0 < COD/BOD > 2.5. COT analyses were in agreement with COD ones, with no significant changes. However, it could be observed in the chromatographic analyses that the H2O2/UV process, apparently, was responsible for a greater degradation of the compounds present in the studied wastewater.
3

Estudo da otimização do processo H2O2/UV para o descoramento de um efluente de indústria têxtil / Optimization study of the H2O2/UV process for decolorization of a textile industry wastewater

Maraissa Silva Franco 23 April 2010 (has links)
Os efluentes gerados pelas indústrias têxteis possuem como características elevada DQO, alta concentração de matéria orgânica não-biodegradável e intensa coloração, já que em média 12% do total de corantes utilizados são perdidos durante a produção. Os azo-corantes são os mais utilizados por possuírem uma alta aderência ao tecido, resistência à luz solar e a processos químicos. Estes corantes possuem como agravante o fato de serem quimicamente resistentes aos métodos de tratamentos biológicos convencionais. Os Processos Oxidativos Avançados (POA) têm sido estudados como uma alternativa promissora para o tratamento de substâncias tóxicas, refratárias e não-biodegradáveis. O presente trabalho tem como objetivo tratar um efluente de uma indústria têxtil utilizando o processo H2O2/UV para o descoramento dos corantes da família Remazol presentes, otimizando o processo a fim de se obter um efluente com características que facilitem o tratamento biológico. Para tanto, elaborou-se um planejamento experimental, com a finalidade de se estimar os efeitos das variáveis independentes pH, temperatura e concentração inicial de peróxido de hidrogênio. Em seguida, foi possível ajustar-se um modelo polinomial aos dados obtidos. A condição ótima de tratamento para as variáveis independentes foi: pH=12,3; temperatura = 52&deg;C e [H2O2] = 3,1 × 10-4 mol L-1. As variáveis-resposta observadas foram a remoção de cor (por meio da integração da área dos espectros na região do visível) e a concentração de peróxido de hidrogênio residual (método do vanadato de amônio). Para o efluente tratado com H2O2/UV, obteve-se uma remoção de cor de aproximadamente 80%, e para a fotólise direta obteve-se um valor de aproximadamente 75%, ambas com duas horas de irradiação. Para o processo H2O2/UV obteve-se uma cinética de primeira ordem, com constante de velocidade igual a (1,5 &plusmn; 0,36) × 10-2 min-1; para a fotólise, obteve-se uma cinética de segunda ordem com k = (2,3 &plusmn; 0,36) × 10-2 u.a.-1 min-1. A razão DQO/DBO não apresentou variação significativa para ambos os processos, mantendo o efluente dentro da faixa 5,0 < DQO/DBO > 2,5. A análise de carbono total foi concordante com os ensaios de DQO, não havendo mudanças significativas. No entanto, pôde-se observar, por meio de análises cromatográficas, que o processo H2O2/UV, aparentemente, foi responsável por uma maior degradação dos compostos presentes no efluente. / The wastewaters generated by the textile industry are known for their high COD, high concentration of non-biodegradable organic matter, and strong color, once approximately 12% of the dyes are lost during production. Azo dyes are the most used due to their high adherence to the fabrics, resistance to sunlight and to chemical processes. Those dyes have also the drawback of being resistant to conventional biological methods. Advanced Oxidation Processes (AOP) have been studied as a promising alternative for treating toxic, refractory, and non-biodegradable pollutants. The present work is aimed at treating the wastewater of a textile industry by the H2O2/UV process in order to remove the color due to the Remazol dyes present, as well as optimizing the process in order to obtain a wastewater easier to be biologically treated. For that purpose, an experimental design was performed to assess the effects of independent variables pH, temperature, and hydrogen peroxide concentration. Next, a polynomial model was fit to the obtained data. The optimum treatment condition was: pH = 12.3; temperature = 52&deg;C, and [H2O2] = 3.1 × 10-4 mol L-1. The response variables were color removal (measured by the area under the spectra obtained in the visible region) and the residual concentrations of H2O2 (vanadate method). Color removals of approximately 80 and 75% were achieved, for H2O2/UV and direct photolysis, respectively, both after two hours of irradiation. The decolorization kinetics of the H2O2/UV process followed a first order model, with a constant (k) of (1.5 &plusmn; 0.36) × 10-2 min-1, while the effluent treated with the direct photolysis showed a second order behavior, with k = (2.3 &plusmn; 0.36) × 10-2 u.a.-1 min-1. The COD/BOD ratio remained practically unchanged for both process, in the range of 5.0 < COD/BOD > 2.5. COT analyses were in agreement with COD ones, with no significant changes. However, it could be observed in the chromatographic analyses that the H2O2/UV process, apparently, was responsible for a greater degradation of the compounds present in the studied wastewater.
4

Estudo, otimização e aplicação de microondas acoplado ao processo oxidativo avançado H2O2/UV na degradação da tartrazina / Study, optimization, and application of microwaves coupled to the H2O2/UV advanced oxidation process in the degradation of tartrazine

Fernanda Parolin 11 August 2011 (has links)
Os corantes azo são amplamente utilizados em muitas indústrias, entre elas as alimentícias, farmacêuticas e têxteis. Quando essas moléculas estão presentes no efluente industrial tornam o seu tratamento, que na maioria dos casos é biológico, difícil. Suas complexas estruturas são altamente estáveis e a presença de grupos sulfônicos (-SO3H) torna o corante ácido e altamente solúvel em água. Um exemplo deste tipo de corante é a tartrazina que pode causar efeitos adversos para a saúde humana, como alergia. Desde o início dos anos 70, quando os Processos Oxidativos Avançados (POAs) foram reconhecidos por sua capacidade de degradar poluentes em meio aquoso, houve um aumento significativo nas pesquisas por duas razões: a diversidade de tecnologias envolvidas e a grande variedade de efluentes que os POAs são capazes de tratar. A fotoquímica assistida por microondas (MO) consiste na combinação de dois tipos distintos de radiação eletromagnética, microondas e UV/VIS, na ativação de reações químicas. Frequentemente está associada ao uso de uma lâmpada de descarga sem eletrodo (LDE) que gera radiação ultravioleta (UV) sob a influência de um campo de microondas. O presente trabalho tem como objetivo tratar uma solução de tartrazina (25 mg L-1) utilizando o processo H2O2/UV/MO e otimizando-o a fim de se obter a maior degradação com a utilização da menor quantidade de oxidante possível. Para tanto, elaborou-se um planejamento fatorial com a finalidade de observar o comportamento das variáveis independentes pH e concentração inicial de peróxido de hidrogênio no processo. A partir dos resultados, elaborou-se um planejamento composto central a fim de se ajustar um modelo polinomial aos dados obtidos. A condição ótima de tratamento para as variáveis independentes foi: pH = 2,6 e [H2O2] = 2 &times; 10-3 mol L-1. A variável-resposta observada foi a remoção de cor (por meio da integração da área dos espectros na região do visível). A cinética obtida para o processo H2O2/UV/MO foi de ordem zero, com k = 3,9 &times; 10-2 u.a.-1 min-1 e, aproximadamente, 92% de descoramento em 24 minutos. A biodegradabilidade (DBO5/DQO) e a análise de carbono orgânico total (COT) não apresentaram variação significativa. No entanto, pôde-se observar, através da CE50, que o processo H2O2/UV/MO reduziu a fitotoxicidade da solução de tartrazina, indicando a possível formação de intermediários de degradação menos tóxicos que a molécula original. A avaliação do efeito das microondas foi feita pelo estudo da degradação da solução de tartrazina através dos processos H2O2, MO, H2O2/MO e UV/MO, sendo que o descoramento não passou de 20%, indicando que as MO influenciam no processo H2O2/UV devido ao possível sinergismo com a radiação UV e também pelos possíveis efeitos térmicos e não térmicos exercidos por essa radiação. / Azo dyes are extensively used in many industries such as food, drugs, and textiles ones. When these molecules are present in the industrial wastewaters, they make their treatment, which is in most cases a biological one, quite difficult. Their complex structures are very stable and the presence of sulfonic groups (-SO3H) makes the azo dyes acid and highly water-soluble. Tartrazine is an example of these dyes and can cause adverse effects to human health, like allergy. Since the early 70\'s, when Advanced Oxidation Processes (AOPs) were recognized by their capacity of degrading pollutants in aqueous media, there was a significant increase in research and for two reasons: the diversity of technologies involved and the many kinds of wastewaters that AOP can treat. The microwave-assisted photochemistry is the combination of two distinct types of electromagnetic radiations: microwave (MW) and UV/VIS. It is often associated with the use of an electrodeless discharge lamp (EDL), which generates ultraviolet (UV) radiation when placed in a microwave field. The aim of the present work is to treat a solution of tartrazine (25 mg L-1) by the H2O2/UV/MW process, as well as optimizing the process in order to obtain degradation with the use of the lowest possible amount of oxidant. For that purpose, a factorial design was performed to observe the effect of the independent variables pH and hydrogen peroxide concentration. With the results obtained, a composite central design was performed to fit a polynomial model to the data. The optimum treatment condition was: pH = 2.6 and [H2O2] = 2 &times; 10-3 mol L-1. The response variable was color removal (measured by the area under the spectra obtained in the visible region). The decolorization kinetics of the H2O2/UV/MW process followed a zero order model, with k = 3,9 &times; 10-2 u.a.-1 min-1 and color removal achieved 92% in 24 minutes. The biodegradability (BOD5/COD) ratio and total organic carbon (TOC) analyses showed no significant changes. However, through the CE50 maybe observed that the H2O2/UV/MW process reduced the toxicity of the tartrazine solution, indicating the possible formation of less toxic intermediates than the original molecule. The microwaves effect was assessed in a degradation study of the tartrazine solution by H2O2, MW, H2O2/MW, and UV/MW processes, and the decolorization did not exceed 20%, indicating that the MW influence the H2O2/UV process because of the possible synergism with the UV radiation and thermal and non-thermal effects exerted by the radiation.
5

Estudo de remoção de cor de efluentes têxteis por meio do processo oxidativo avançado: UV/H2O2 / Study of color removal of textile effluents by means of advanced oxidation processes: UV/H2O2

Bezerra, Katia Crystina Hipólito 09 September 2015 (has links)
A indústria têxtil utiliza grandes quantidades de água e como consequência gera efluente que apresenta um alto potencial de impacto ambiental. Este trabalho teve como objetivo o tratamento de efluentes têxteis produzidos com corantes reativos por processo de oxidação avançada H2O2/UV, os efluentes foram produzidos em laboratório segundo as condições de processos industriais e foram utilizados nos estudos de reuso em um novo processo de tingimento. Foram produzidos efluentes através dos tingimentos com três corantes reativos um amarelo Drimaren Cl-2R um vermelho Drimaren Cl-5B e um azul Drimaren, na concentração de 1,1% individualmente e em conjunto, compondo uma tricromia a 1,2%. Foram adicionados 14,71 mmol. L-1 peróxido de hidrogênio nas amostras residuais de efluentes e estas foram colocadas no reator de fotodegradação com radiação UV, foram utilizados como fonte de irradiação três lâmpadas de 6 Watts capazes de emissão de UV 1,7 Watts. As amostras foram coletadas e analisadas em intervalos de até 270 minutos de irradiação. Este processo foi executado em três faixas de pH diferentes, 4,0; 7,0 e 11,0, sendo que no pH 4,0 o processo foi mais eficiente com resultados de remoção de cor superiores a 91,12 ± 3,09%. Estas águas de reuso foram utilizadas para novos tingimentos nas mesmas condições e analisadas por meio de colorimetria resultando em valores de E menores que 0,62. Foram realizadas analises de carbono orgânico total (COT), as quais também corroboraram com os resultados anteriores, uma vez que demonstram que existe redução da carga orgânica de até 43,22%. Foram realizadas medições de condutividade dos banhos e assim foi possível fazer a correção de cloreto de sódio nos banhos dos processos de tingimentos posteriores, permitindo assim a redução da adição de cloreto de sódio nos banhos. / The textile industry uses big quantities of water and normally as consequence the effluent has a high environmental impact. This study aimed treat textile effluents produced with reactive dyes by advanced H2O2 / UV oxidation process, the effluents were produced in the laboratory under conditions of industrial processes and have been used in studies of reuse in a new dying process. The effluents were produced by dying with three reactive yellow Drimaren dye CL 2R, red Drimaren CL 5B and blue Drimaren HF-RL in concentration of 1.1% individually and in combination, comprising a trichromy of 1.2%. In the waste effluent was added 14.71 mmol.L-1 hydrogen peroxide and these samples were placed on a photodegradation reactor where was used three lamps 6 Watts UV able to emit 1.7 Watts each of them. The samples were collected and analyzed at intervals of up to 270 minutes of irradiation. This process was performed in three different pH ranges, 4,0; 7,0 and 11,0, and at pH 4,0 the process was more efficient with color removal rate higher than 91,12 ± 3,09%.%.This reuse water has been used for new dying under the same conditions and analyzed through colorimetry resulting in lower E values than 0.62. The total organic carbon analysis (TOC), which also corroborate the previous results, since it shows that there is a reduction of the organic load of up to 43.22%. The bath conductivity measurements were carried out and it was possible to make the adjustment of sodium chloride in the further dying processes allowing the reduction of sodium chloride added in the baths.
6

Estudo e otimização da degradação dos herbicidas hexazinona e diuron utilizando processos oxidativos avançados (POA): H2O2/UV e foto-Fenton / Study and optimization of the degradation of the herbicides diuron and hexazinone using advanced oxidation processes (AOP): H2O2/UV and photo-Fenton

Alysson Stefan Martins 27 February 2013 (has links)
Agrotóxicos são frequentemente relatados na literatura em contaminações de ambientes aquáticos, sendo provenientes do lixiviamento de solos, do descarte inadequado de embalagens agrícolas, dentre outros. Nesse contexto, os processos oxidativos avançados (POA) têm sido estudados como alternativa para o tratamento desses compostos em meio aquoso. Os POA consistem na oxidação de compostos orgânicos pela formação de radicais livres com alto poder oxidante. Diante desses aspectos, o presente trabalho teve como proposta o estudo da degradação dos herbicidas hexazinona e diuron, aliada ao planejamento experimental do tipo composto central, a fim de otimizar o processo de degradação. Para tanto, realizaram-se as degradações através dos processos H2O2/UV e foto-Fenton em concentrações iniciais próximas a 7 e 20 mg L-1 para a hexazinona e diuron, respectivamente. Os experimentos foram conduzidos em um reator fotoquímico (200 mL a 25 &deg;C) com aplicação de irradiação UV, proveniente de uma lâmpada de Hg (degradação H2O2/UV) e de luz negra (degradação foto-Fenton). No processo via H2O2/UV foram avaliadas a concentração de H2O2 (0,65 a 13,34 mmol L-1) e pH (2,77 a 11,23), e para o processo foto-Feton avaliou-se a concentração de H2O2 (0,09 a 29,1 mmol L-1) e Fe (II) (0,01 a 0,92 mmol L-1). Como variável independente, utilizou-se a remoção de Carbono Orgânico Total (COT) nos dois casos. A eficiência na degradação dos herbicidas foi determinada através das técnicas de Espectroscopia UV-Vis, Cromatografia Líquida de Alta Eficiência (HPLC/UV), remoção de Carbono Orgânico Total e Cromatografia de Íons. A análise dos modelos matemáticos, obtidos a partir dos planejamentos, possibilitou a avaliação da influência das variáveis, determinando as melhores condições. No processo H2O2/UV observou-se que a influência da variável H2O2 é maior comparada ao pH. A melhor condição de degradação apresentou concentrações de H2O2 iguais a 7 mmol L-1 e valores de pH de 2,8. Como resultado, obteve-se 96 % de remoção do COT e a não detecção de ambos os herbicidas após 2 minutos de reação. No processo foto-Fenton, a realização de três planejamentos foi necessária para a otimização do sistema. Primeiro e segundo planejamentos indicaram a melhor condição, enquanto que o terceiro planejamento revelou que concentrações elevadas de H2O2 e Fe2+ não garantem maior eficiência. As condições ideais encontradas foram iguais a 0,291 mmol L-1 para o Fe2+ e 2,91 mmol L-1 para o H2O2, obtendo-se 76 % de remoção do COT e não detecção dos herbicidas nos primeiros minutos de degradação. Em ambas as degradações não foi possível observar diferenças em relação a cinética de degradação para os herbicidas. A degradação via H2O2/UV mostrou melhor desempenho, pois apresentou maior taxa de mineralização além de não necessitar o emprego do íon Fe(II). / Pesticides are often reported in the literature on aquatic environments contamination, being a result of soil leaching, improper disposal of agricultural packages, among others. In this context, advanced oxidation processes (AOP) have been studied as an alternative to treat these compounds in aqueous medium. The AOP consist in the oxidation of organic compounds through the formation of free radicals with a high oxidizing power. Considering these aspects, the present work aimed to study degradation of the herbicides diuron and hexazinone, coupled with an experimental setup as central compost, in order to optimize the degradation process. For this purpose, the degradation was carried out by H2O2/UV and photo-Fenton processes at initial concentrations close to 7 and 20 mg L-1 to hexazinone and diuron, respectively. The experiments were conducted in a photochemical reactor (200 mL at 25 &deg; C) with application of UV irradiation from Hg lamp (H2O2/UV degradation) and black-light (photo-Fenton degradation). In the H2O2/UV process, the concentrations of H2O2 (0.65 to 13.34 mmol L-1) and pH (2.77 to 11.23) were evaluated, and in the photo-Fenton process, the concentrations of H2O2 (0.09 to 29.1 mmol L-1) and Fe (II) (0.01 to 0.92 mmol L-1) were analyzed. In both processes, the removal of Total Organic Carbon (TOC) was used as an independent variable. The efficiency of the herbicide degradation was determined by UV/Vis spectroscopy, high performance liquid chromatography (HPLC/UV), removal of the Total Organic Carbon and ion chromatography. The analysis of the mathematical models obtained from the experimental setup allowed the evaluation of the variables influence ,determining the best conditions. The H2O2/UV process showed that the influence of the H2O2 is higher compared to that of the pH. The best degradation condition presented H2O2 concentrations of 7 mmol L-1 and a pH value of 2.8. As a result, 96% TOC removal was observed, and none of the herbicides were detected after 2 minutes of reaction. In the photo-Fenton process, the conduction of three setups was necessary to confirm the best condition. The first and second setups indicated the best condition, while the third one showed that high concentrations of H2O2 and Fe2+ do not guarantee a greater degradation efficiency. Ideal conditions were equal to 0.291 mmol L-1 for Fe2+ and 2.91 mmol L-1 for H2O2, where 76% of TOC removal was obtained and also no herbicides detection was seen in the early minutes of degradation. In both processes, it was not possible to observe differences in the degradation kinetics of the herbicides. The H2O2/UV degradation showed better performance because of a greater mineralization rate besides not requiring the ion Fe (II) use.
7

Estudo e otimização da degradação dos herbicidas hexazinona e diuron utilizando processos oxidativos avançados (POA): H2O2/UV e foto-Fenton / Study and optimization of the degradation of the herbicides diuron and hexazinone using advanced oxidation processes (AOP): H2O2/UV and photo-Fenton

Martins, Alysson Stefan 27 February 2013 (has links)
Agrotóxicos são frequentemente relatados na literatura em contaminações de ambientes aquáticos, sendo provenientes do lixiviamento de solos, do descarte inadequado de embalagens agrícolas, dentre outros. Nesse contexto, os processos oxidativos avançados (POA) têm sido estudados como alternativa para o tratamento desses compostos em meio aquoso. Os POA consistem na oxidação de compostos orgânicos pela formação de radicais livres com alto poder oxidante. Diante desses aspectos, o presente trabalho teve como proposta o estudo da degradação dos herbicidas hexazinona e diuron, aliada ao planejamento experimental do tipo composto central, a fim de otimizar o processo de degradação. Para tanto, realizaram-se as degradações através dos processos H2O2/UV e foto-Fenton em concentrações iniciais próximas a 7 e 20 mg L-1 para a hexazinona e diuron, respectivamente. Os experimentos foram conduzidos em um reator fotoquímico (200 mL a 25 &deg;C) com aplicação de irradiação UV, proveniente de uma lâmpada de Hg (degradação H2O2/UV) e de luz negra (degradação foto-Fenton). No processo via H2O2/UV foram avaliadas a concentração de H2O2 (0,65 a 13,34 mmol L-1) e pH (2,77 a 11,23), e para o processo foto-Feton avaliou-se a concentração de H2O2 (0,09 a 29,1 mmol L-1) e Fe (II) (0,01 a 0,92 mmol L-1). Como variável independente, utilizou-se a remoção de Carbono Orgânico Total (COT) nos dois casos. A eficiência na degradação dos herbicidas foi determinada através das técnicas de Espectroscopia UV-Vis, Cromatografia Líquida de Alta Eficiência (HPLC/UV), remoção de Carbono Orgânico Total e Cromatografia de Íons. A análise dos modelos matemáticos, obtidos a partir dos planejamentos, possibilitou a avaliação da influência das variáveis, determinando as melhores condições. No processo H2O2/UV observou-se que a influência da variável H2O2 é maior comparada ao pH. A melhor condição de degradação apresentou concentrações de H2O2 iguais a 7 mmol L-1 e valores de pH de 2,8. Como resultado, obteve-se 96 % de remoção do COT e a não detecção de ambos os herbicidas após 2 minutos de reação. No processo foto-Fenton, a realização de três planejamentos foi necessária para a otimização do sistema. Primeiro e segundo planejamentos indicaram a melhor condição, enquanto que o terceiro planejamento revelou que concentrações elevadas de H2O2 e Fe2+ não garantem maior eficiência. As condições ideais encontradas foram iguais a 0,291 mmol L-1 para o Fe2+ e 2,91 mmol L-1 para o H2O2, obtendo-se 76 % de remoção do COT e não detecção dos herbicidas nos primeiros minutos de degradação. Em ambas as degradações não foi possível observar diferenças em relação a cinética de degradação para os herbicidas. A degradação via H2O2/UV mostrou melhor desempenho, pois apresentou maior taxa de mineralização além de não necessitar o emprego do íon Fe(II). / Pesticides are often reported in the literature on aquatic environments contamination, being a result of soil leaching, improper disposal of agricultural packages, among others. In this context, advanced oxidation processes (AOP) have been studied as an alternative to treat these compounds in aqueous medium. The AOP consist in the oxidation of organic compounds through the formation of free radicals with a high oxidizing power. Considering these aspects, the present work aimed to study degradation of the herbicides diuron and hexazinone, coupled with an experimental setup as central compost, in order to optimize the degradation process. For this purpose, the degradation was carried out by H2O2/UV and photo-Fenton processes at initial concentrations close to 7 and 20 mg L-1 to hexazinone and diuron, respectively. The experiments were conducted in a photochemical reactor (200 mL at 25 &deg; C) with application of UV irradiation from Hg lamp (H2O2/UV degradation) and black-light (photo-Fenton degradation). In the H2O2/UV process, the concentrations of H2O2 (0.65 to 13.34 mmol L-1) and pH (2.77 to 11.23) were evaluated, and in the photo-Fenton process, the concentrations of H2O2 (0.09 to 29.1 mmol L-1) and Fe (II) (0.01 to 0.92 mmol L-1) were analyzed. In both processes, the removal of Total Organic Carbon (TOC) was used as an independent variable. The efficiency of the herbicide degradation was determined by UV/Vis spectroscopy, high performance liquid chromatography (HPLC/UV), removal of the Total Organic Carbon and ion chromatography. The analysis of the mathematical models obtained from the experimental setup allowed the evaluation of the variables influence ,determining the best conditions. The H2O2/UV process showed that the influence of the H2O2 is higher compared to that of the pH. The best degradation condition presented H2O2 concentrations of 7 mmol L-1 and a pH value of 2.8. As a result, 96% TOC removal was observed, and none of the herbicides were detected after 2 minutes of reaction. In the photo-Fenton process, the conduction of three setups was necessary to confirm the best condition. The first and second setups indicated the best condition, while the third one showed that high concentrations of H2O2 and Fe2+ do not guarantee a greater degradation efficiency. Ideal conditions were equal to 0.291 mmol L-1 for Fe2+ and 2.91 mmol L-1 for H2O2, where 76% of TOC removal was obtained and also no herbicides detection was seen in the early minutes of degradation. In both processes, it was not possible to observe differences in the degradation kinetics of the herbicides. The H2O2/UV degradation showed better performance because of a greater mineralization rate besides not requiring the ion Fe (II) use.
8

Estudo de remoção de cor de efluentes têxteis por meio do processo oxidativo avançado: UV/H2O2 / Study of color removal of textile effluents by means of advanced oxidation processes: UV/H2O2

Katia Crystina Hipólito Bezerra 09 September 2015 (has links)
A indústria têxtil utiliza grandes quantidades de água e como consequência gera efluente que apresenta um alto potencial de impacto ambiental. Este trabalho teve como objetivo o tratamento de efluentes têxteis produzidos com corantes reativos por processo de oxidação avançada H2O2/UV, os efluentes foram produzidos em laboratório segundo as condições de processos industriais e foram utilizados nos estudos de reuso em um novo processo de tingimento. Foram produzidos efluentes através dos tingimentos com três corantes reativos um amarelo Drimaren Cl-2R um vermelho Drimaren Cl-5B e um azul Drimaren, na concentração de 1,1% individualmente e em conjunto, compondo uma tricromia a 1,2%. Foram adicionados 14,71 mmol. L-1 peróxido de hidrogênio nas amostras residuais de efluentes e estas foram colocadas no reator de fotodegradação com radiação UV, foram utilizados como fonte de irradiação três lâmpadas de 6 Watts capazes de emissão de UV 1,7 Watts. As amostras foram coletadas e analisadas em intervalos de até 270 minutos de irradiação. Este processo foi executado em três faixas de pH diferentes, 4,0; 7,0 e 11,0, sendo que no pH 4,0 o processo foi mais eficiente com resultados de remoção de cor superiores a 91,12 ± 3,09%. Estas águas de reuso foram utilizadas para novos tingimentos nas mesmas condições e analisadas por meio de colorimetria resultando em valores de E menores que 0,62. Foram realizadas analises de carbono orgânico total (COT), as quais também corroboraram com os resultados anteriores, uma vez que demonstram que existe redução da carga orgânica de até 43,22%. Foram realizadas medições de condutividade dos banhos e assim foi possível fazer a correção de cloreto de sódio nos banhos dos processos de tingimentos posteriores, permitindo assim a redução da adição de cloreto de sódio nos banhos. / The textile industry uses big quantities of water and normally as consequence the effluent has a high environmental impact. This study aimed treat textile effluents produced with reactive dyes by advanced H2O2 / UV oxidation process, the effluents were produced in the laboratory under conditions of industrial processes and have been used in studies of reuse in a new dying process. The effluents were produced by dying with three reactive yellow Drimaren dye CL 2R, red Drimaren CL 5B and blue Drimaren HF-RL in concentration of 1.1% individually and in combination, comprising a trichromy of 1.2%. In the waste effluent was added 14.71 mmol.L-1 hydrogen peroxide and these samples were placed on a photodegradation reactor where was used three lamps 6 Watts UV able to emit 1.7 Watts each of them. The samples were collected and analyzed at intervals of up to 270 minutes of irradiation. This process was performed in three different pH ranges, 4,0; 7,0 and 11,0, and at pH 4,0 the process was more efficient with color removal rate higher than 91,12 ± 3,09%.%.This reuse water has been used for new dying under the same conditions and analyzed through colorimetry resulting in lower E values than 0.62. The total organic carbon analysis (TOC), which also corroborate the previous results, since it shows that there is a reduction of the organic load of up to 43.22%. The bath conductivity measurements were carried out and it was possible to make the adjustment of sodium chloride in the further dying processes allowing the reduction of sodium chloride added in the baths.
9

Tratamento combinado de efluentes da indústria têxtil por ultrafiltração e H2O2/UV / Combined treatment of textile industry wastewaters by ultrafiltration and H2O2/UV

Dutra, Henrique Simões Rosa 27 August 2010 (has links)
Made available in DSpace on 2015-03-26T13:27:59Z (GMT). No. of bitstreams: 1 texto completo.pdf: 1685233 bytes, checksum: 2d7aab22adfe49e2d84420a0580054a2 (MD5) Previous issue date: 2010-08-27 / Conselho Nacional de Desenvolvimento Científico e Tecnológico / Effluents from textile industries are recalcitrant to biological degradation, resulting in problems such as low on color removal and COD removal. In this paper, alternatives to conventional treatments of effluents from the textile industry were investigated. They have applied advanced oxidation process for effluent treated H2O2/UV alone for treated wastewater and in combination with ultrafiltration for the raw wastewater and treated by activated sludge extended aeration. The application of the various proposed treatments aimed to increase the removal of recalcitrant organic matter (COD), color and acute toxicity and identify interfering with each treatment. The experiment based on response surface method was applied to evaluate the interactive effects of factors (pH, dose of H2O2 and reaction time) on the removal efficiency of COD and color, and optimize the operational conditions of each treatment process investigated. The effects were determined by measuring the concentration of COD and color. The models for COD and color removal in the combined treatment (UF + H2O2/UV) were well adjusted, resulting in optimized parameters such as pH = 6, dose of H2O2 = 8 mmol.L-1 and reaction time = 80 minutes were the variables optimized for this process, it reached an efficiency of 90% for COD and color. In applying (Activated Sludge + H2O2/UV) the treated effluent by activated sludge was not possible to generate a model, because none of the factors was significant, analysis of response surfaces was obtained as optimized parameters pH = 3, dose H2O2 = 12 mmol.L-1 and reaction time = 60 minutes, it reached an efficiency of 85% to 75% for COD and color. Finally the application of combined treatment (BRM + H2O2/UV) presented model well suited for color removal, but not presented for COD, and pH = 7, dose of H2O2 = 5 mmol.L-1 and reaction time of 50 minutes with removal efficiency of 95% of COD and 87% color. / Efluentes de indústrias têxteis apresentam recalcitrância à degradação biológica, resultando em problemas como baixa remoção de cor e relativa remoção de DQO. Neste trabalho, alternativas aos tratamentos convencionais de efluentes da indústria têxtil foram investigadas. Aplicou-se o processo oxidativo avançado H2O2/UV isoladamente para efluente tratado e em conjunto com a ultrafiltração para o efluente bruto e tratado por sistema de lodos ativados de aeração prolongada. Da aplicação dos diferentes tratamentos propostos objetivou-se aumentar a remoção da matéria orgânica recalcitrante (DQO), cor e toxicidade aguda e identificar interferentes a cada tratamento. O delineamento experimental baseado no método de superfície de resposta foi aplicado para avaliar os efeitos interativos de fatores (pH, dose de H2O2 e tempo de reação) sobre a eficiência de remoção de DQO e cor e otimizar as condições operacionais do processo de cada tratamento investigado. Os efeitos foram determinados pela medida da concentração de DQO e cor. Os modelos gerados para remoção DQO e cor no tratamento combinado (UF+H2O2/UV) foram bem ajustados, obtendo-se como variáveis otimizadas pH = 6, dose de H2O2 = 8 mmol.L-1 e Tempo de reação = 80 minutos foram as variáveis otimizadas para este processo, onde alcançou uma eficiência de 90% para DQO e cor. Na aplicação de (Lodos Ativados + H2O2/UV) ao efluente tratado pelo sistema de lodos ativados não foi possível gerar um modelo, pois nenhum dos fatores foi significativo, da análise das superfícies de reposta obteve-se como variáveis otimizadas pH = 3, dose de H2O2 = 12 mmol.L-1 e Tempo de reação = 60 minutos, onde alcançou uma eficiência de 85% para DQO e 75% para cor. Por fim a aplicação do tratamento combinado (BRM + H2O2/UV), apresentou modelo bem ajustado para remoção de cor, porém não apresentou para DQO, sendo pH = 7, dose de H2O2 = 5 mmol.L-1 e tempo de reação de 50 minutos, com eficiência de remoção de 95% da DQO e 87% da cor.
10

APLICAÇÃO DE PROCESSOS OXIDATIVOS AVANÇADOS HOMOGÊNEOS E HETEROGÊNEOS NA DEGRADAÇÃO DE EFLUENTES DE CURTUME

Flores, Rubia Gomes 31 January 2008 (has links)
This study investigated the application of advanced oxidative processes for the homogeneous and heterogeneous degradation of a tanning effluent. The catalytic activity of a solid oxide containing manganese was evaluated in the heterogeneous systems. The experiments were performed in a photocatalytic batch reactor in laboratory scale. The solid used was the commercial product Birm®, consisting mainly of crystalline silica, silicate, aluminum and manganese dioxide. The adsorption results using Birm® in synthetic sewage adjusted to the models of Langmuir and Freundlich and established that the adsorption capacity of the Birm ® is low. The synthetic and real tannery effluents were assessed by the degradation kinetics of photochemical homogeneous (H2O2/UV) processes and heterogeneous (UV/H2O2/Birm®) at different pH, concentration of H2O2 and catalyst. The degradation kinetics of the ES followed in law and kinetics order of pseudofirst showing that the Birm® presented no catalytic activity in appreciable color degradation of the synthetic effluent. But when the solid was evaluated for the degradation of the real tannery effluent, it proved to be active, with kinetics of degradation occurring more efficiently than the homogeneous system (H2O2/UV) one. In both effluents there was a catalytic decomposition of hydrogen peroxide. However, the decomposition in ES resulted in inactive products for the catalytic oxidation or free radicals, which possibly were disabled in difusional ways and didn t react with the effluent. The increasing of the concentration of nitrate and sulfate also demonstrated a good the treatment of tanning effluent. / Este estudo investigou a aplicação de processos oxidativos avançados, homogêneos e heterogêneos, na degradação de efluentes líquidos industriais de couro sintético e real. O efluente sintético é uma solução aquosa do corante de couros Acid Orange G. O efluente real é oriundo da indústria de processamento de couro, coletado após o decantador secundário do tratamento por lodos ativados. Os experimentos foram realizados em reator fotocatalítico descontínuo em escala de laboratório. O sólido utilizado como catalisador heterogêneo é um composto comercial denominado Birm®, constituído principalmente de sílica cristalina, silicato de alumínio e dióxido de manganês. A adsorção do efluente sintético sobre o Birm® ajustou-se aos modelos de Langmuir e de Freundlich e, o sólido apresentou baixa capacidade adsortiva. As cinéticas de degradação dos efluentes pelos processos fotoquímicos homogêneo (H2O2/UV) e heterogêneo (UV/H2O2/Birm®) foram avaliadas em diferentes valores de pH, concentração de H2O2 e de catalisador. Os resultados estabeleceram o modelo cinético de pseudoprimeira ordem para a degradação do efluente sintético. O Birm® apresentou atividade catalítica apenas para o efluente de curtume, apesar de a decomposição catalítica do peróxido de hidrogênio ter ocorrido em ambos efluentes. Supõe-se que essa atividade foi potencializada pela diversidade de compostos orgânicos presentes no efluente de curtume. A degradação deste efluente também foi comprovada pelo aumento das concentrações de sulfato e nitrato.

Page generated in 0.0419 seconds